Home

Samsung ND020NHXBA User Manual

image

Contents

1. NDS2eze2NHe2e2e2 IB 31939 E 1 25 10 indd 27 O cleaning and maintaining _27 2010 1 25 17 05 17 E a i cleaning and maintaining tne alr conartioner REPLACING THE FILTER Replacement filter may be purchased from the retail store or ordered from the dealer where you purchased the unit If you cannot find one please call a contact center Deodorizing filter Deodorizing filter absorbs efficiently cigarette smoke pet odors and other unpleasant smells Deodorizing filter cleaning is simple just remove old filter and install a new one 1 Remove the front panel Tightly grab both side of the front panel and lift up the panel to open Then slide the panel towards you to remove the panel OTU TITI ASS IN TM 7 rn N AAA e Deodorizing filter can be placed in any 4 slots beneath the air filter e Front panel of your air conditioner is actually not detachable 3 Install the new Deodorizing filter back in position 4 Close the front panel Q e The replacement timing of the Deodorizing filter differs depending on usage and environmental conditions e Even if Deodorizing and Anti allergy filters are installed in an inverted position it will not affec
2. ND 22222 NHE2F2F2 B 31939 E 1 25 10 indd 1 2010 1 25 17 03 82 features of your new alr C onaoltioner Cool Summer Offer On those hot sweltering summer days and long restless nights there is no better escape from the heat than the cool comforts of home Your new air conditioner brings an end to exhausting hot summer days and lets you rest This summer beat the heat with your own air conditioner Cost Efficient System Your new air conditioner not only provides maximum cooling power in the summer but can also be an efficient heating method in the winter with the advanced Heat pump system This technology is up to 300 more efficient than electrical heating so you can further reduce its running cost Now meet year round needs with one air conditioner A Look for Everywhere The elegant and harmonious design gives priority to the esthetics of your space and complements any of your existing interior d cor With its soft color and rounded edge shape the new air conditioner adds class to any room Enjoy what your air conditioner offers both functionally and esthetically good sleep function good sleep mode allows you to set a comfortable sleep temperature while saving energy and having sound sleep IP For easy future reference write the model and serial number Model down You will find your model number on the right side of Serial the air conditioner erial 02_ features ND 2
3. Da For example If the On timer is set at 3 hours and a ie F the Off timer at 5 hours the air conditioner willtun sis off automatically 3 hours after the set time and Bl then operate for next 2 hours before turning off automatically Set Cancel KOZ N SY On timer is longer than Off timer Lig LE A The air conditioner will turn off and then on On Timer automatically Set up should be done while the air risa ia CDN conditioner is operating ot m For example If the On timer is set at 3 hours and SE the Off timer at 1 hour the air conditioner will turn off gt 9 automatically an hour after the set time and remain off F C for 2 hours before turning on automatically ood sleep K See page 22 for more detail instructions on setting Off timer To deactivate the timer combination 1 Press the Power amp Set Cancel button on the remote control Both of the On and Off timer will be canceled and the indicators will disappear using advanced functions _23 NDSRafafaNHRafafa IB 31939 E 1 25 10 indd 23 2010 1 25 17 04 58 E e LO E USING advanced iuncilons SETTING TIMER good sleep mode good sleep mode allows you to set a comfortable sleep temperature while saving energy and having sound sleep good sleep mode can be set up when the air conditioner is on 1 Set the operating mode Press the Mode bu
4. EEE is compliant with RoHS ND NH IB_31939_E 10 11 13 indd 34 2010 11 13 13 29 38 Wall Mounted Type Series Neo Forte ND NH x x 100 Recycled Paper imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com register E DB98 31939A 1 ex 2011 7 23 15 19 04 NDMONHo00_IB_31939_E_10 11 13 indd 35
5. a TC gt Low Medium High Activate Deactivate air flow blade a movement automatically up and down On Timer On timer lt Set the on timer on Adjust the time for On timer Off timer Set the off timer on cy Adjust the time for Off timer SL Power l amp Set Cancel Turn on off the air conditioner and set cancel the timer function good sleep good sleep r K Set the good sleep mode on off Q Each time you press the button a short beep will sound and a transmit indicator appears on the remote control display 12_ viewing NDSRafafaNHfRafafa IB 31939 E 1 25 10 indd 12 O 2010 1 25 17 04 01 4 Cool SET TEMP Oy Bray Set temperature indicator 4 ree eg Fan E gt D D jt yt Heat D good sleep indicator em al H Fan speed indicator ma a ital of Aut Air swing indicator gt aul Auto Zi sta Low On Timer indicator stup Medium Sal High good sleep Off Timer OFF TIM stai Turbo indicator yt Lt DE bal ur 4 J Low battery indicator Using the remote control e Point the remote control towards the remote control sensor of the unit e When properly pressing the button on the remote control you will hear beep sound from the unit Z e The signal may not be received well of electronic lighting style fluorescent lamps such as inverter fluorescent lamps are in the same space e f other electrical products operate by the remote control c
6. and current is measured according to ISO standard for energy efficiency Check for damage on delivery If damaged do not install the air conditioner and call the place of purchase immediately Keep indoor temperatures stable and not extremely cold especially where there are children elderly or disabled people The packaging material and used batteries of the remote controller optional must be disposed of in accordance with the national standards CS The refrigerant used in the air conditioner must be treated as chemical waste D Dispose the refrigerant following national standards Have a qualified service technician install the air conditioner and perform a trial operation Firmly connect the drain hose to the air conditioner for proper water drainage Check for damages on the outdoor unit installation pad at least once a year e Potential risk of personal injury or property loss When using a wireless remote control the distance should not be more than 7 meters from the air conditioner If the remote control is not used for a long period of time remove the batteries to prevent leakage of electrolyte When cleaning the outdoor unit touch the heat exchanger radiator fins with extreme care e Wearing thick gloves can protect your hands Make sure that the condensed water dripping from the drain hose runs out properly and safely The appliance is not intended for use by persons including children with reduced ph
7. button on the remote control until Cool mode indicator appears on the remote control display The air conditioner operates in Cool mode and it will lower the temperature in your room When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the temperature Press the Temperature A or V button on the remote control to increase or decrease the desired temperature SET TEMP wy Wo pudi You can set the desired temperature between the range of 16 C 30C 000e You can increase decrease the temperature by 1 C 4 Set the fan speed ODE Press the Fan Speed button on the remote control to set the desired fan speed If room temperature reaches desired value the air conditioner will shut off cooling for a while and just the fan runs OEE Z When you press the Fan Speed amp button fan speed will change in order of Auto Low Medium and High e When you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually See page 19 for instructions e f current outside temperatures are much higher than the selected indoor temperature it may take time to bring the inner temperature to the desired coolness operating _15 NDSRafafaNHRafafa IB 31939 E 1 25 10 indd 15 O 2010 1 25 17 04 20 E e
8. excessive shock to the air conditioner e Potential risk of fire or unit malfunction and there are risk of personal injury because unit may fall down Do not spray water directly on the air conditioner or use benzene thinner or alcohol to clean the surface of the unit e Potential risk of electric shock or fire e Potential risk of damage to the air conditioner Do not place any objects especially containers with liquid 06_ safety information NDS2e2e2NHe2e2e2 IB 31939 E 1 25 10 indd 6 O 2010 1 25 17 03 53 e BOR Do not touch the pipe connected to the air conditioner Install the indoor unit away from lighting apparatus using the ballast e f you use the wireless remote control reception error may occur due to the ballast of the lighting apparatus Install the outdoor unit where operating noise and vibration will not disturb your neighbor and in a well ventilated area with no obstacle e Potential risk of malfunction e Operating noise may disturb your neighbor Make sure that there are no obstacles or covers that block the air conditioner Allow sufficient space for air circulation e Insufficient ventilation may result in poor performance If the power cable is damaged the manufacturer or a qualified service technician must replace it If a power outage occurs while the air conditioner is working turn off the power source immediately Max current is measured according to IEC standard for safety
9. 10 O 2010 1 25 17 03 55 E e LO E REMOVING THE FRONT PANEL Tightly grab both side of the front panel and lift up the panel to open Then slide the panel towards to remove the panel PA Oa Power button and Room temperature sensor You may locate the Power l button on the right bottom side of the air conditioner If the front panel is open you can check the room temperature sensor You can turn on the air conditioner without the remote control by pressing the Power l button The room temperature sensor measures indoor room temperature Room temperature 6 sensor Pumm ZI TI i A TTT II AUL MAANA j 1 H Power l button viewing _11 NDSRafafaNHRafafa IB 31939 E 1 25 10 indd 11 O 2010 1 25 17 03 58 a Di VIEWING your ar conditioner CHECKING THE REMOTE CONTROL You can activate the air conditioner by pointing the remote control away from it When using the remote control always point it directly at the air conditioner Remote control display Set one of the 5 operating modes See pages14 18 for instructions Temperature AV Increase decrease the temperature by 1 C Turbo Fan speed Adjust how much air flows through the SP Operate in maximum fan speed to Cu cool warm quickly lt p n 4 different fan speeds such as Auto air conditioner with the Air swing ri
10. 10 1 25 17 05 04 E a E Temperature changes in good sleep mode To prevent excessive cooling heating during sleep the good sleep mode automatically modifies the temperature setting in accordance with the time setting Temperature and air current change according to the three stages Fall asleep Sound sleep and Wake up from good sleep mode and then the air conditioner will automatically turn off when the set time has elapsed Three stage good sleep prevents you from having difficulty sleeping in summer winter night Fall asleep Eases you into sleep by dropping the temperature Sound sleep Relaxes your body and raises your temperature slightly Wake up from good sleep mode Allows you to wake up from comfortable intermittent air and it makes you feel refresh e Set Off timer in good sleep mode over 5 hours You feel disturbed sleep if the good sleep is set too short or long because the default is set to 8 hour operation e f the good sleep mode is set less than 4 hours the operation will stop at the set time lf the good sleep mode is set over 5 hours it will run as Wake up stage for the last one hour before stop e Recommended set temperature is between 25 C 27 C for cooling and 21 C 23 C for heating To deactivate good sleep mode 1 Press the Power D amp Set Cancel button on the remote control good sleep mode you set will be canceled and good sleep i
11. 2 2NHS2F252 IB 31939 E 1 25 10 indd 2 O 2010 1 25 17 03 52 a i satety information To prevent electric shock disconnect the power before servicing cleaning and installing the air conditioner SAFETY INFORMATION Before using your new air conditioner please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance Because the following operating instructions cover various models the characteristics of your air conditioner may differ slightly from those described in this manual If you have any questions call your nearest contact center or find help and information online at www samsung com Important safety symbols and precautions Hazards or unsafe practices that may result in severe personal injury or WARNING death Hazards or unsafe practices that may result in minor personal injury or CAUTION Property damage To reduce the risk of fire explosion electric shock or personal injury when CAUTION using your air conditioner follow these basic safety precautions Do NOT attempt Do NOT disassemble Do NOT touch Follow directions carefully Unplug the power plug from the wall socket Make sure the machine is grounded to prevent electric shock DEEA Call the contact center for help S Note These warning signs are here to prevent injury to you and o
12. LO E operating basic tunction SELECTING OPERATION MODE Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air Dry mode makes the air feel refreshing in a humid climate 1 Turn on the air conditioner Press the Power l amp Set Cancel button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Dry mode indicator appears on the remote control display The air conditioner operates in Dry mode and automatically adjusts the fan speed to Auto 690 iY When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the temperature Press the Temperature A or V button on the Oj remote control to increase or decrease the desired temperature You can set the desired temperature between the range of 18C 30C You can increase decrease the temperature by 1 C iY e When you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually See page 19 for instructions 16_ operating NDSRafafaNHfRafafa IB 31939 E 1 25 10 indd 16 O 2010 1 25 17 04 24 E e LE i Fan Fan mode can be selected to ventilate your room Fan mode will be helpful to refresh the stale air In your room 1 Turn on the air conditioner Press the Po
13. all your nearest contact center Installing the batteries 1 Slide the cover on the 2 Install two AAA batteries 3 Close the cover by sliding it rear side of the remote Check and match the and _ back to its original position control down to open signs accordingly Make You should hear click sound sure you have installed the when the cover is locked batteries in correct position properly viewing _13 NDSRafafaNHRafafa IB 31939 E_1 25 10 indd 13 O 2010 1 25 17 04 07 E a i operating basic function TURNING THE AIR CONDITIONER ON AND OFF Press the Power l amp Set Cancel button on the remote control You will hear a ringing sound and the air flow blade will move up and BI down automatically when the air conditioner is properly on Sepp The air conditioner will operate in the most recent operation mode used or Auto mode good sleep When you turn off the air conditioner air flow blade will stop moving and remain closed Turning on off your air conditioner without the remote control You can operate your air conditioner by pressing the Power D button on the right bottom side of the air conditioner SELECTING OPERATION MODE Auto In Auto mode the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature sensor Oj 1 Turn on the air conditioner Pre
14. can be directed to your desired position Vertical air flow Air flow blades move up and down 1 Press the Air swing button on the remote control Air swing indicator will be on and air flow blades move up and down continuously to circulate the air To keep the air flow direction in a constant position press the Air swing button on the remote control again e lt L lt gt Vv e lt lt 5 Horizontal air flow Make sure one of the blade pins that stick out of the air flow blades are not broken 1 Move the blade pin lever left or right to keep the air flow direction in a constant position you Be extremely careful with your fingers while adjusting the Horizontal air flow direction caution here is a potential risk of personal injury when the unit is mishandled operating _19 NDSRafafaNHRafafa IB 31939 _E_1 25 10 indd 19 O 2010 1 25 17 04 39 E a E USING advanced TUNCTONS USING THE TURBO FUNCTION Turbo function will be helpful to cool or heat your room quickly and effectively by operating at the maximum fan speed for 30 minutes 1 Turn on the air conditioner Press the Power l amp Set Cancel button on the remote control 2 Set the operating mode Press the Turbo button on the remote control until Turbo indicator appears on the remote control display The air conditioner operates in Turbo fan spe
15. decrease the temperature Check if the air filter is blocked by dirt Clean the Air filter every two weeks Check if the air conditioner has just been turned on If so wait 3 minutes D Check if you selected Auto or Dry mode The air conditioner automatically adjusts the fan speed to Auto in Auto Dry mode Timer function does not set Check if you press the Power D amp Set Cancel button on the remote control after you have set the time Odors permeate in the room during operation Check if the appliance is running in a smoky area or if there is a smell entering from outside Operate the air conditioner in Fan mode or open the windows to air out the room The air conditioner makes a bubbling sound Water is dripping from the air flow blades A bubbling sound may be heard when the refrigerant is circulating through the compressor Let the air conditioner operate in a selected mode Check if the air conditioner has been cooling for an extended period of time with the air flow blades pointed downwards Condensation may generate due to the difference in temperature Remote control is not working ND 22222 NHE2F2S2 B 31939 E 1 25 10 indd 31 Check if your batteries are depleted Make sure batteries are correctly installed Make sure nothing is blocking your remote control sensor Check that there are strong lighting apparatus near the air conditioner Strong light which comes from fluorescent b
16. ditioner operates in Heat mode and warms your room Z When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the temperature Press the Temperature A or Y button on the xX remote control to increase or decrease the desired D temperature You can set the desired temperature between the range of 16 C 30C You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan Speed c amp button on the remote control to set the desired fan speed If room temperature reaches desired value heating will stop for a while iY e When you press the Fan Speed s amp button fan speed will change in order of Auto Low Medium and High e Fan may not operate for about 3 5 minutes at the beginning to prevent any cold blasts while the air conditioner is warming up iY e Air flow can be adjusted manually See page 19 for instructions e Since the air conditioner heats the room by taking heat energy from outdoor air the heating capacity may decrease when outdoor temperatures are extremely low If you feel the air conditioner insufficiently heats using an additional heating appliance in combination with the air conditioner is recommended 18_ operating NDSRafafaNHRafafa IB 31939 E 1 25 10 indd 18 O 2010 1 25 17 04 34 E a i ADJUSTING THE AIR FLOW DIRECTION Air flow
17. drain pan 2 iY The checks and maintenance operations described are essential to guarantee the efficiency of the air conditioner The frequency of these operations varies according to the characteristics of the area the amount of dust etc 1 The described operations should be performed more frequently if the area of installation is very dusty 2 These operations must always be performed by qualified personnel For more detailed information see the Installation Manual cleaning and maintaining _29 NDSRafafaNHRafafa IB 31939 E 1 25 10 indd 29 O 2010 1 25 17 05 20 a E cleaning and maintaining tne alr conartloner MAINTAINING YOUR AIR CONDITIONER Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner Type Description The internal fan will be off to against cold air when the heat pump is Against cold air heating The internal fan will be off to against cold air when the heat pump is De ice cycle heating Anti protection of The compressor will be off to protect internal battery when the air internal battery conditioner operates in Cool mode The air conditioner does not start operating immediately to protect the Protect compressor compressor of the outdoor unit after it has been started cy Z If the heat pump is operating in Heat mode De ice cycle is actuated to remove frost fr
18. e On Timer button to change time setting and then press the Power l amp Set Cancel button to active it on To deactivate the On timer 1 Press the Power amp Set Cancel button on the remote control On timer you set will be canceled and On timer indicator will disappear using advanced functions _21 2010 1 25 17 04 48 E a i USING advanced TUNCTIONS SETTING TIMER Off timer This function allows you to turn off the air conditioner automatically within the time range of 24 hours Off timer is functional when the unit is operating 1 Press the Off Timer button on the remote control Off timer indicator blinks on the remote control display 2 Set the time you want the air conditioner to turn off automatically Press the Off Timer button on the remote control to change the time setting while Off timer indicator is blinking You can set the time up to 24 hours increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours 3 Press the Power amp Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set The air conditioner will turn off automatically at set time and then Off timer indicator disappears If Off timer is not set within 10 seconds the air conditioner will end setting e Setting time allows you to change by pressing the Off Timer button Press the Off Timer butto
19. ed and automatically adjusts the temperature according to the Current room temperature The unit operates for 30 minutes and then operates in last used mode or in Auto mode if Dry Fan mode is most recent mode used Z Turbo function is only available in Auto Cool Heat mode If Turbo function is selected in Dry Fan mode operating mode changes to Auto To deactivate Turbo function 1 Press the Turbo button on the remote control again The air conditioner operates in last used mode or in Auto mode if Dry Fan mode is most recent mode used Z e When you are using the remote control make sure corresponding indicator appears on the remote control display e Temperature Fan speed cannot be adjusted while using this function e Air flow can be adjusted manually See page 19 for instructions e When the Turbo function is activated pressing Mode button will automatically cancel the function 20_ using advanced functions NDSRafafaNHRafafa IB 31939 E 1 25 10 indd 20 O 2010 1 25 17 04 43 E NDfRafagaNHgafafa IB 31939 E 1 25 10 indd 21 SETTING TIMER This advanced Timer function allows you to turn on off your air conditioner automatically even when you are away Simply set the time and your air conditioner will turn on off automatically On timer This function allows you to turn on the air conditioner automatically within the time range of 24 hours On timer is available while your air conditi
20. ify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines Use a rated circuit breaker only e Never use steel wires or copper wires as a circuit breaker It may cause fire or unit malfunctions Do not put undue stress or place heavy object on the power cable Do not bend the power cable excessively e Potential risk of fire or electric shock To protect the product from water and possible shock you should keep the power cable and the connection cord of the indoor and outdoor units in the protection tube When opening or closing the front panel use a stable stool and watch your steps carefully Disconnect the air conditioner from power supply before it is repaired or disassembled Clean the air conditioner after the inner fan stops operating e Potential risk of injury or electric shock safety information _05 NDS2e2e2NHe2e2e2 IB 31939 E 1 25 10 indd 5 O 2010 1 25 17 03 53 CEER e DOOM Salety Information AN SEVERE WARNING SIGNS CONT D WARNING Use a receptacle that has a ground terminal The receptacle must be used exclusively for the air conditioner e Improper electrical grounding may cause electric shock or fire Be sure to ground the unit Do not connect the ground wire to gas or water pipes lighting rods or teleph
21. n to change the time setting and then press the Power l amp Set Cancel button to active it on e You can combine Off timer function with On timer function to turn on and then off the air conditioner at the desired time See page 23 for instructions To deactivate the Off timer 1 Press the Power amp Set Cancel button on the remote control Off timer you set will be canceled and Off timer indicator will disappear 22_ using advanced functions NDSRafafaNHRafafa IB 31939 E 1 25 10 indd 22 O 2010 1 25 17 04 53 E a i Combining On timer and Off timer You can combine the On timer and Off timer together for more convenient use of the timer function 1 Set the On timer Press the On Timer button Set the time with On Timer button Press Power amp Set Cancel button to activate the On timer j OOD poz Y E 3 a E e a A e 8 See page 21 for more detail instructions on setting On timer 2 Set the Off timer Press the Off Timer button Set the time with Off Timer button Press Power amp Set Cancel button to activate the Off timer When you set the time there can be two possible options On timer is shorter than Off timer e PA a m A The air conditioner will turn on and then off automatically Set up should be done while the air conditioner is off ae 5 ai Off Timer fe 4 n E ma m A
22. ndicator will disappear using advanced functions _25 NDSRafafaNHRafafa IB 31939 E 1 25 10 indd 25 2010 1 25 17 05 08 E a Di cleaning and maintaining tne alr conartloner CLEANING THE EXTERIOR 1 Wipe the surface of the unit with a slightly wet or dry cloth when needed Do not use Benzene Thinner or Clorox caution Mey May damage the surface of the air conditioner and can create a risk of fire CLEANING THE FILTER When cleaning the filter make sure to unplug the power from the unit No special tools are needed to clean it Air filter Washable foam based air filter captures large particles from the air The filter is cleaned with a vacuum or by hand washing 1 Remove the front panel Tightly grab both side of the front panel and lift up the panel to open Then slide the panel towards you to remove the panel NI T cA iy p HN 2 Grab the handle and lift it uo Then pull the Air filter towards you ee 3 Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy then rinse it with running water and dry it in a ventilated area 4 e For the best conditions repeat every two weeks e f the Air filter dries in a confined or h
23. ner e Potential risk of electric shock or fire Do not insert anything such as fingers or branches into the air conditioner vents while the air conditioner is running e Keep the children away from the air conditioner to prevent them from putting their finger on the air conditioner Potential risk of personal injury Ensure no water gets into the air conditioner e Potential risk or electric shock e f the water gets into the air conditioner stop and unplug the power source immediately Turn off the air conditioner using the provided remote control or control accessory if provided Do not unplug to turn off the unit unless there is an immediate danger Do not run the air conditioner for an extended period of time in a room with the door closed or with babies elderly or disabled people e Open the door or windows to ventilate your room at least once an hour to prevent oxygen shortage The air conditioner is composed of moving parts Keep children away from the unit to avoid physical injury 04_ safety information NDS2e2e2NHe2e2e2 IB 31939 E 1 25 10 indd 4 O 2010 1 25 17 03 53 CEER e DOM N Make sure that children take precautions against access to the air conditioner and they do not play with the unit Do not clean the interior of air conditioner on your own e You may damage the parts which can cause electric shock or fire e Consult contact center for cleaning the interior of the air conditioner D
24. not observed as indicated into the Installation Manual the cost necessary to reach and repair the unit in safety as required by current regulations in force with slings trucks scaffolding or any other means of elevation won t be considered in warranty and charged to end user Ensure the off on and protection switches are properly installed Do not use the air conditioner if damaged If problems occur immediately stop operation and disconnect the plug from the power supply If the air conditioner will not be used for an extended period of time for example over several months unplug the power from the wall Call the place of purchase or a contact center if repairs are needed e Potential risk of fire or electric shock if disassembly or repairs are attempted by a non qualified service technician 08_ safety information NDS2e2e2NHe2e2e2 IB 31939 E 1 25 10 indd 8 O 2010 1 25 17 03 54 contents VIEWING YOUR AIR CONDITIONER OPERATING BASIC FUNCTION USING ADVANCED FUNCTIONS CLEANING AND MAINTAINING ND 22222NHE2F2L2 B 31939 E 1 25 10 indd 9 THE AIR CONDITIONER APPENDIX 10 10 10 11 11 12 13 13 13 14 14 14 15 16 17 18 19 19 19 20 21 21 22 23 24 26 26 26 27 28 28 29 29 30 31 32 Checking the indoor unit and digital display Main parts Display Removing the front panel Power button and Room temperature sensor Checking the remote control Remote c
25. o not connect the air conditioner with heating apparatus or attempt to disassemble remodel or repair it yourself e Potential risk of malfunction electric shock or fire If repairs are needed consult the contact center Consult the place of purchase or contact center to install reinstall or disassemble the air conditioner e Improper installation carries a risk of unit malfunction water leakage electric shock or fire e f installing in specialty areas such as a factory complex or saline coastal area consult the place of purchase or contact center for specific installation details e The units must be installed according to distances declared in order to permit accessibility from each side either to guarantee correct operation of maintenance or repairing products The unit s parts must be reachable and removable completely under safety condition for people or things Consult a dealer regarding the appropriate measures to prevent the allowable concentration from being exceeded e f the refrigerant leaks and cause the concentration limit to be exceeded hazards due to lack of oxygen in the room may result If the indoor unit gets wet turn the power off immediately and call your nearest contact center e Potential risk of fire or electric shock Always make sure that the power supply is compliant with current safety standards Always install the air conditioner in compliance with current local safety standards Ver
26. om cy an outdoor unit that may have deposited at low temperatures The internal fan is switched off automatically and restarted only after the de ice cycle is completed 30_ cleaning and maintaining NDSRafafaNHfRafafa IB 31939 _E_1 25 10 indd 30 O 2010 1 25 17 05 20 aooendalx TROUBLESHOOTING Refer to the following chart if the air conditioner operates abnormally This may save time and unnecessary expenses PROBLEM SOLUTION The air conditioner does not operate immediately after it has been restarted Because of the protective mechanism the appliance does not start operating immediately to keep the unit from overloading The air conditioner will start in 3 minutes The air conditioner does not work at all Check that the power plug is properly connected Insert the power plug into the wall socket correctly Check if the circuit breaker is switched off Check if there is a power failure Check your fuse Make sure it is not blown out The temperature does not change Check if you selected Fan mode Press the Mode button on the remote control to select another mode The cool warm air does not come out of the air conditioner The fan speed does not change Check if the set temperature is higher lower than the current temperature Press the Temperature A or V button on the remote control to change the set temperature Press the Temperature A or Y button to increase or
27. one grounding lines e f the unit is not properly grounded electric shock may result If you smell burning plastic hear strange sounds or see smoke coming from the unit unplug the air conditioner immediately and call a contact center e Potential risk of fire or electric shock CAUTION SIGNS CAUTION Do not block or place items in front of the air conditioner Do not step hang onto or place heavy items on the air conditioner e Potential risk of personal injury If failure or damage occurs on the conditions of improper use not followed by the installation manual there will be an extra labor charge for installing and construction e Potential risk of malfunction electric shock or fire if repairs or installations are attempted e by a non qualified service technician e Do not spray flammable gases such as insecticide near the air conditioner e Potential risk of electric shock fire or unit malfunction Do not open the front grille during operation e Potential risk of electric shock or unit malfunction Cool air should not flow directly towards people pets and plants e lt is harmful to your health pets and plants Do not drink drain water coming out of the air conditioner e Potential risk of health hazard Do not allow children to climb on the air conditioner Do not use the air conditioner as a cooling precision instrument for food pets plants cosmetics or machinery Do not pull or give
28. oner is on off 1 Press the On Timer button on the remote control On timer indicator blinks on the remote control display E m e LME D ag 2 Set the time you want the air conditioner to turn on automatically Press the On Timer button on the remote control to change the time setting while On timer indicator is blinking G You can set the time up to 24 hours increasingin30 goodsleep eL minute unit up to first 3 hours and in hourly unit after y A lt first 3 hours 3 Press the Power amp Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set The air conditioner will operate automatically at set time and then On timer indicator disappears If On timer is not set within 10 seconds the air conditioner will end setting 4 Set the operating mode Press the Mode button on the remote control until the desired mode appears on the remote control display The air conditioner will operate in the mode you set Z On timer function is available in Auto Cool Dry Fan Heat mode SZ e Temperature can also be adjusted See step 3 on page 15 for instructions e After the set up while the unit is off approximately after 10 seconds all the other indicators will be gone except the On timer indicator and remaining time e Setting time allows you to change by pressing the On Timer button Press th
29. ontrol display Using the remote control Installing the batteries Turning the air conditioner on and off Selecting operation mode Auto Cool Dry Fan Heat Adjusting the air flow direction Vertical air flow Horizontal air flow Using the Turbo function Setting timer On timer Off timer Combining On timer and Off timer good sleep mode Cleaning the exterior Cleaning the filter Air filter Anti allergy filter Replacing the filter Deodorizing filter Maintaining your air conditioner Periodical checks Internal protections via the unit control system Troubleshooting Operation ranges contents 09 2010 1 25 17 03 54 VIEWING your ar condiiioner Congratulations on the purchase of the air conditioner We hope you enjoy the features of your air conditioner and stay cool or warm with optimal efficiency Please read the user manual to get started and to make the best use of the air conditioner CHECKING THE INDOOR UNIT AND DISPLAY Carefully unpack your air conditioner and check the unit to make sure it is not damaged Main parts Air filter under the panel L Air intake IL Blade pin lever Display Operation indicator E Timer indicator i A Turbo indicator E 9 Power button Z Your air conditioner may slightly look different from illustration shown above depending on your model 10_ viewing NDfRafagaNHgafafa IB 31939 E 1 25 10 indd
30. ss the Power amp Set Cancel button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Auto mode and Auto fan speed indicator appear on the remote control display The air conditioner will automatically set the operation mode to Cool or Heat depends on the room temperature Q When you press the Mode button mode will change in order of Auto Cool Heat 3 Set the Temperature Press the Temperature A or V button on the remote control to increase or decrease the desired temperature You can set the desired temperature between the range of 16 C 30 C You can increase decrease the temperature by 1 C K e When the air conditioner is already operating in another mode press the Mode button until Auto mode indicator appears on the remote control display e When you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually See page 19 for instructions 14_ operating NDSRafafaNHfRafafa IB 31939 E 1 25 10 indd 14 O 2010 1 25 17 04 14 E Cool In Cool mode the air conditioner will cool your room You can adjust the temperature and the fan speed to feel cooler in hot season 1 Turn on the air conditioner Press the Power amp Set Cancel button on the remote control 2 Set the operating mode Press the Mode
31. t its filtration system 28_ cleaning and maintaining NDSRafafaNHfRafafa IB 31939 E 1 25 10 indd 28 O 2010 1 25 17 05 19 a i MAINTAINING YOUR AIR CONDITIONER If the air conditioner will not be used for an extended period of time dry the air conditioner to maintain it in best condition 1 Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug There may be internal damage if moisture is left in components 2 Before using the air conditioner again dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours This helos remove odors which may have generated from dampness Periodical checks Refer to the following chart to maintain the air conditioner properly Every 4 Once a Type Description Monthly months year Clean the air filter 1 Clean the condensate drain pan 2 Indoor unit Thoroughly clean the heat exchanger 2 Clean the condensate drain pipe 2 O Replace the remote control batteries 1 9 Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 ud Outdoor unt Verify that all the electric components are Pe firmly tightened 2 Clean the fan 2 Verify that all the fan assembly is firmly Pe tightened 2 Clean the condensate
32. thers Please follow them carefully After reading this section keep it in a safe place for future reference safety information _03 NDSRafafaNHRafafa IB 31939 E 1 25 10 indd 3 O 2010 1 25 17 03 53 CEER DOOM Saiety information SEVERE WARNING SIGNS WARNING N Do not place the air conditioner near hazardous substances or equipment that releases free flames to avoid fire explosions or injuries e Potential risk of fire hazard or explosion Do not install the outdoor unit at an unstable place or elevated surface where there is potential risk of falling e f the outdoor unit falls it may cause personal injury or loss of property Failure or damage may occur if any changes or modification that is not stated in the installation manual was performed In this case user will be responsible for the repair expenses Install the air conditioner away from direct exposure to sunlight heating apparatus and humid places e Hang curtains on windows to boost cooling efficiency and to avoid the risk of electric shock Do not cut the power plug and connect to a different power cable Do not yank the power cable and touch the power plug with hands e Potential risk of fire or electric shock Never use a damaged or dusted power plug power cable or loosened power receptacle e Potential risk of fire or electric shock Install an exclusive circuit breaker and short circuit breaker for the air conditio
33. tton on the remote control until Cool Heat appears on the remote control display good sleep js only available in Cool Heat mode 2 Press the good sleep button on the remote control good sleep indicator appears and Off timer indicator starts blinking on the remote control display j COLLO E 3 Set the length of time you want the air conditioner to stay on gt e Default good sleep time is set to 8 hours Press good sleep button on the remote control to change the time setting while Off timer indicator is blinking S N lt You can set the time up to 12 hours increasing in PD om 30 minute unit up to first 3 hours and in hourly unit after first 3 hours 4 Press the Power amp Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set When the set time has elapsed the air conditioner will automatically turn off and then good sleep indicator disappears If good sleep mode is not set within 10 seconds the air conditioner will end setting 4 e Temperature Fan speed Air swing can be adjusted after setting good sleep in Heat mode e Temperature can be adjusted and the air conditioner automatically adjusts the Fan speed Air swing after setting good sleep in Cool mode 24_ using advanced functions NDSRafafaNHfRafafa IB 31939 E 1 25 10 indd 24 O 20
34. ulbs or neon signs may interrupt the electric waves appendix _31 O 2010 1 25 17 05 20 aDDENAIX OPERATION RANGES The table below indicates the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use OPERATIONAL TEMPERATURE MODE INDOOR HUMIDITY IF OUT OF CONDITIONS INDOOR OUTDOOR Condensation may occur on COOLING 18Cto32C 5cto43 rae either water blow off or drops on the floor HEATING 27 C or less 20 C to 24 C i Internal protection triggers and the air conditioner will stop Condensation may occur on DRYING 18 C to 32 C BC to 43 C i the indoor unit with risk to have either water blow off or drops on the floor The standardized temperature for heating is 7 C If the outdoor temperature drops to OC or below the heating capacity can be reduced depending on the temperature condition Oj If the cooling operation is used at over 32 C indoor temperature it does not cool at its full capacity iC 32_ appendix ND 22222NHE2F2F2 B 31939 E 1 25 10 indd 32 2010 1 25 17 05 20 ND 22222NHE2F2F2 B 31939 E 1 25 10 indd 33 appendix _33 2010 1 25 17 05 20 QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT 1 800 10 SAMSUNG 726 7864 1 800 3 SAMSUNG 726 7864 1 800 8 SAMSUNG 726 7864 02 5805777 PHILIPPINES www samsung com EEE Yonetmeligine Uygundur This
35. umid area odors may generate If it occurs re clean and dry it in a well ventilated area 4 Insert the Air filter back in its original position 5 Close the front panel 26_ cleaning and maintaining NDSRafafaNHRafafa IB 31939 E 1 25 10 indd 26 O 2010 1 25 17 05 11 E Anti allergy filter Washable foam based Anti allergy filter leads to reduction in allergens that thrive in polluted air The filter is cleaned with a vacuum or by hand washing 1 Remove the front panel Tightly grab both side of the front panel and lift up the panel to open Then slide the panel towards you to remove the panel MMN MT 5 LL Lo E m ze i i ati I EI ID j S iiis mT THT TITI TI UE Z e Anti allergy filter can be placed in any 4 slots beneath the air filter e Front panel of your air conditioner is actually not detachable cy 3 Clean the Anti allergy filter with a vacuum cleaner or soft brush Then rinse it with running cy water and dry it in a ventilated area 4 Install the Anti allergy filter back in position 5 Close the front panel Clean the Anti allergy filter every 3 months The cleaning term may differ on usage and environmental conditions
36. wer amp Set Cancel button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Fan mode indicator appears on the remote control display The air conditioner operates in Fan mode and automatically adjusts the temperature according to the current room temperature When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the fan speed OO Press the Fan Speed button on the remote control to set the desired fan speed CH a When you press the Fan Speed button fan speed will change in order of Auto Low Medium and High e When you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually See page 19 for instructions operating _17 NDSRafafaNHRafafa IB 31939 E 1 25 10 iindd 17 O 2010 1 25 17 04 28 E e LI E operating basic tunction SELECTING OPERATION MODE Heat The air conditioner heats as well as cools Warm your room with this versatile appliance in the cold of winter 1 Turn on the air conditioner Press the Power l amp Set Cancel button on the remote control 2 Set the operating mode Press the Mode button on the remote control until amp Heat mode indicator appears on the remote control display The air con
37. ysical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Young children should be supervised to ensure that they do not play with the appliance safety information _07 NDS2e2e2NHe2e2e2 IB 31939 E 1 25 10 indd 7 2010 1 25 17 03 53 CEER 4 Ww satety information CAUTION CAUTION SIGNS CONT D Inspect the condition electric connections pipes and external case of the air conditioner regularly by a qualified service technician Do not open doors and windows in the room being cooled during operation unless necessary Do not block the air conditioner vents If objects block the air flow it may cause unit malfunction or poor performance Make sure there are no obstacles under the indoor unit e Potential risk of fire or loss of property The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs The units components must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is

Download Pdf Manuals

image

Related Search

Related Contents

Solac ME7710  Manuel ego t shopclop  3M 2080EL-48N Installation Guide    SuperSnake GT02S, GT02SW    Télécharger - Pascal Hérault  VSP 618 User Manual V1.5  PDF manual (instructions)  Manual de servicio WIWA Professional  

Copyright © All rights reserved.
Failed to retrieve file