Home
Samsung AR09JRFLBWKXME User Manual
Contents
1. Soft rubber designed to cut off vibration from rack to wall not supplied with product English 45 TCL ODM CO IB amp IM_EN indd 45 2014 11 19 2A 9 40 55 Final check and trial operation To complete the installation perform the following checks and tests to ensure that the air conditioner operates correctly Check the followings e Strength of the installation site e Tightness of pipe connection to detect gas leak Electric wiring connection e Heat resistant insulation of the pipe e Drainage e Grounding conductor connection e Correct operation follow the steps below gt The indicator on the indoor unit lights up 1 Press the Power button and check the following Ko gt The airflow blade opens and the fan gears up for operation 2 Press the Mode button to select Cool mode Temn Ean 4 fA P AEN Fan gt In Cool mode use Temp or button and set the temperature at 17 C Approximately 3 5 minutes later outdoor unit will start to operate and the Note Cool air will blow out After 12 minutes of stationary condition check the indoor unit air treatment Cooling mode indoor unit check gt Inlet air temp Outlet air temp From 10 C to 12 C indicative delta T 3 Press the Air swing button and check the following gt The airflow blade
2. 20 A e Make sure to drill only one hole after choosing the direction of the pipe CAUTION 2 Fix the indoor unit If you fix the indoor unit on a wall 1 Fix the installation plate to the wall giving attention to the weight of the indoor unit p If you mount the plate to a concrete wall using plastic anchors make sure that gaps est between the wall and the plate created by projected anchor is less than 20 mm en Yi lt 20 mm 7 Vi If you fix the indoor unit on a window frame z 1 Determine the positions of the wooden uprights to be attached to the window frame 2 Attach the wooden uprights to the window frame giving attention to the weight ofthe indoor unit 3 Attach the installation plate to the wooden upright using tapping screws If you fix the indoor unit on a gypsum board 1 Use stud finder to find out locations of the studs 2 Fix the plate hanger on two studs Search for other spots if there are less than two studs or the distance between the studs are different from the caution Plate hanger e Fix the installation plate without inclining to one side English 34 TCL ODM CO IB amp IM_EN indd 34 2014 11 19 2A 9 40 51 Connecting the assembly cable Cable specification Model Power cable Interconnection cable 09 12 3G1 0 mm HO5VV F 3G1 0 mm HO7RN F Connect the power cable to the auxiliary circuit breaker If every pole fails to connect to the power supply
3. INDOOR UNIT gt OUTDOOR UNIT NYD MIA Also circular terminal must be matched with screw size in terminal block caution After connecting the cables make sure terminal numbers on the indoor outdoor unit matches Please ensure that Power amp Communication cables are separated they must not be in the same cable 10 Connect the grounding conductor to the grounding terminals 11 Close the terminal board cover by tightening the screw carefully In Russia and Europe consult with the supply authority to determine the supply system impedance before NOTE installation A Connect the wires firmly so that wires can not be pulled out easily If they are loose it could cause burn out of the wires Connect the wires according to color codes referring to the wiring diagram The power cable and the interconnection cable should be selected according to the specification in page 35 WARNING English 36 TCL ODM CO IB amp IM_EN indd 36 2014 11 19 2A 9 40 51 Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field supplied copper pipes by means of flare connections Use insulated seamless refrigeration grade pipe only Cu DHP type according to IS01337 degreased and deoxidized suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa Under no circumstances must sanitary type copper pipe be used
4. TCL ODM CO IB amp IM_EN indd 42 2014 11 19 2A 9 40 53 Important information regulation regarding the refrigerant used This product contains fluorinated greenhouse gases covered by the Kyoto Refrigerant type GWP value Protocol Do not vent gases into the atmosphere R 410A 1975 X GWP Global Warming Potential 1 Please fill in with indelible ink gt the factory refrigerant charge of the product Contains fluorinated greenhouse gases covered by the Kyoto Protocol NOILWTIVLSNI SO gt the additional refrigerant amount charged in the field and gt the total refrigerant charge on the refrigerant charge label Indoor unit supplied with the product E a Factory refrigerant charge of the product NOTE see unit name plate d D b Additional refrigerant amount charged in the field Refer to the above information for the quantity of refrigerant a Outdoor unit replenishment kg c Total refrigerant charge kg D kg d Refrigerant cylinder and manifold for charging c Charging the refrigerant under conditions of liquid by using a liquid pipe R 410A is a mixed type of refrigerant It is necessary for recharging under conditions of liquid When recharging refrigerant from the refrigerant cylinder to the equipment follow the instructions below 1 Before recharging check whether the cylinder has a siphon or not There are two ways to recharge the refrigerant Cy
5. There are 2 refrigerant pipes of different diameters The smaller one is for the liquid refrigerant The larger one is for the gas refrigerant A short pipe is already fitted to the air conditioner You may need to extend the pipe using the assembly pipe optional The connection procedure for the refrigerant pipe varies according to the exit position of the pipe when facing the wall non Right A Pre Left B E Underside C AH 4B e Rear EF J C 1 Cut out the appropriate knock out piece A or B on the rear of the DuterDamete Torque indoor unit unless you connect the pipe directly from the rear Nem kgfecm 2 Smooth the cut edges 26 35 mm 14 18 140 180 4 3 Remove the protection caps of the pipes and connect the assembly 2 Mn 920430 pipe to each pipe Tighten the nuts first with your hands and then 012 70 mm 49 61 500 620 with a torque wrench applying the following torque 015 88 mm 68 82 690 830 B e Ifyou want to shorten or extend the pipes refer to page 38 49 NOTE 4 Cut off the remaining foam insulation 5 Ifnecessary bend the pipe to fit along the bottom of the indoor unit Then pull it out through the appropriate hole gt The pipe should not project from the rear of the indoor unit gt The bending radius should be 100 mm or more 6 Pass the pipe through the hole in the wall 7 For further details on how to connect to the outdoor uni
6. English 41 TCL ODM CO IB amp IM_EN indd 41 2014 11 19 NOILWTIVLSNI SO 2A 9 40153 Evacuating the connected pipes The outdoor unit is loaded with sufficient R 410A refrigerant Do not vent R 410A into atmosphere it is a fluorinated greenhouse gas covered by Kyoto Protocol with a Global Warming Potential GWP 1975 You should evacuate the air in the indoor unit and in the pipe If air remains in the refrigerant pipes it affects the compressor It may cause reduction of cooling capacity and malfunction Use Vacuum Pump as seen in the picture e When installing make sure there is no leakage When recovering the refrigerant ground the compressor first before removing the connection pipe If the refrigerant pipe is not properly connected and the compressor works with the service valve open the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high It may cause explosion and injury 1 Connect each assembly pipe to the appropriate valve on the outdoor unitand Outdoor unit Indoor unit tighten the flare nut Gas pipe side 2 Tighten the flare nut first with your hands and then with a torque wrench andre applying the following torque B Excessive torque can be cause of gas leakage NOTE Outer Torque Diameter Nem kgfecm 3 Connect the charging hose of the low pressure side of manifold gauge to a 06 35 mm 14 18 140 180 gas service port a
7. IN d D j ud Drain hose Pipe Donttie drain hose to the assembly pipe which may lead to water leakage CAUTION English 40 TCL ODM CO IB amp IM_EN indd 40 The drain hose must not be bent 2014 11 19 QA 9 40 53 Drain hose installation 1 lfnecessary connect the 2 meter extension drain hose to the drain hose 2 Ifyou use the extension drain hose insulate the inside of the extension drain hose with a shield za 3 Fitthe drain hose into drain hose hole then fix the end of the drain hose tightly with a clamp A ooo i BE EN PO Drain hose hole 4 Passthe drain hose under the refrigerant pipe keeping the drain hose tight Shield 5 Passthe drain hose through the hole in the wall Check if it slants EN A downwards as seen in the picture A CAUTION A Drain hose Extension drain hose The hose will be fixed permanently into position after finishing the installation and the gas leak test refer to page 44 for further details Make sure the installed direction of the drain hose is correct Inadequate installation may cause condensate water leakage If the drain hose is routed inside the room insulate the hose so that dripping condensation does not damage the furniture or floors DO NOT WALL UP THE DRAIN HOSE CONNECTION Drain hose connection must be easy accessible and serviceable
8. 9 40 49 Maintaining the air conditioner If the air conditioner will not be used for an extended period of time dry the air conditioner to maintain it in best condition 1 Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut off the power supply There may be internal damage if moisture is left in components SYAHLO 70 2 Before using the air conditioner again dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours This helps remove odors which may have generated from dampness Periodical checks Refer to the following chart to maintain the air conditioner properly Description Every 1 months Clean the air filter 1 1 The described operations should be performed more frequently if CAUTION the area of installation is very dusty 2 These operations must always be performed by qualified personnel For more detailed information see the installation part in the manual English 25 TCL ODM CO IB amp IM_EN indd 25 2014 11 19 2A 9 40 49 Troubleshooting Refer to the following chart if the air conditioner operates abnormally This may save time and unnecessary expenses PROBLEM SOLUTION The air conditioner Check power status and then operate the air conditioner does not work at again all Plug in or switch on the circuit breaker and then operate the air conditioner again Ensure Isolator is switch on The t
9. A After peeling off the tube wire you must insert a contraction tube CAUTION 2 Insert both sides of core wire of the power cable into the connection sleeve 3 Using a compressor compress the two points and flip it over and compress another two points in the same location The compression dimension should be 8 0 After compressing it pull both sides of the wire to make sure it is firmly pressed Te it 4 times mm 5 4 Wrap it with the insulation tape twice and position your Insulation tape contraction tube in the middle of the insulation tape p 5 Apply heat to the contraction tube to contract it 40 mm tube Insulation tape gt e In case of extending the electric wire please DO NOT use a round shaped pressing socket 6 Aftertube contraction work is completed wrap it with the insulation tape to finish A Incomplete wire connections can cause electric shock or a fire gt English 47 TCL ODM CO IB amp IM_EN indd 47 2014 11 19 2 9 40 56 QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT 021 56997777 l INDONESIA 08001128888 www samsung com id support TCL ODM CO IB amp IM_EN indd 48 2014 11 19 2A 9 40 56
10. can be selected Vertical air swing can be selected English 21 TCL ODM CO IB amp IM_EN indd 21 2014 11 19 2A 9 4047 Cleaning the air conditioner e Make sure to turn off the power of the indoor unit and cut off CAUTION the power supply before cleaning the air conditioner Cleaning the indoor unit gt Wipe the surface of the unit with a slightly damp micro fiber cloth when needed Contact the service center when you clean the indoor unit heat exchanger because it needs to be disassembled Since the panel of the indoor unit is easily scratched you should use a micro fiber cloth to clean the panel When you use the micro fiber cloth slightly dampen the cloth and remove any debris on the cloth to avoid scratches e Do not clean the display using alkaline detergent CAUTION Do not use sulfuric acid hydrochloric acid organic solvents such as thinner kerosene and acetone etc to clean the surface of the product or put any stickers on it They may damage the surface of the air conditioner Cleaning the outdoor unit heat exchanger gt When dustaccumulates on the heat exchanger it may decrease cooling performance Therefore clean it regularly gt Spray water to clean the dust If it is difficult to clean the outdoor unit heat exchanger on NOTE your own contact service center A AE Be careful with the sharp edges on th
11. it must be incorporated in a wire with a contact opening of gt 3 mm Use shield cable Category 5 less than 50pF m for noisy environmental site NOILWTIVLSNI SO The Interconnection cable is optional If it is not supplied use the standard cable Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord Code designation IEC 60227 IEC53 CENELEC HO5VV F IEC 60245 IEC 66 CENELEC HO7RN F Connecting the cable Electrical work 1 For electrical and earth works comply with the technical standards of electrical installations and the the wiring regulations of the Local wiring regulations 2 Tighten the terminal block screw to 1 2 1 8N m 12 18kgf cm 3 Precautions when connecting terminal blocks of the indoor unit gt Before connecting make sure the connecting part of the terminal socket is facing upwards There isnqiing terminalto cover the wire The terminal Upside down socketis damaged i gt There must be no space between the terminal and the screw when connected Any remaining space may become a fire hazard due to overheating of the electrical contact Either the4ex ew is not fitted roperly of there is a space etween thelscrew and the ring terminal The terminal socket is upside down For the terminal block wiring use a wire with a ring terminal socket only Regular wires without a
12. Ib wae Outer Tightening torque Diameter i Body cap Nem Charging port cap l mm Nem R 22 Diameter of the screw 7 16 20UNF R 410A Diameter of the screw 1 2 20UNF 0033 en 09 52 20 25 012 70 25 30 10 12 Tightening torque for charging port cap J Refer to the table pies ee 019 05 35 40 To check for gas leaks on the outdoor unit 1 Nem 10 kgfecm Check the valve A and B using a leak detector To check for gas leaks on the indoor unit Check the flare nut C and D using a leak detector English 44 TCL ODM CO IB amp IM_EN indd 44 2014 11 19 2A 9 40 54 Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priory After checking for gas leaks in the system insulate the pipe hose and cables Insulation Then place the indoor unit on the installation plate 1 To minimise condensation problems wrap foam insulation as shown in the figure on a part without insulation on the end of the pipes 2 Wind the pipe assembly cable and drain hose with vinyl tape 3 Place the bundle the pipe assembly cable and drain hose in the lower part of the indoor unit carefully so it does not project from the rear of the indoor NOILWTIVLSNI SO unit Installation l plate 4 Hook the indoor unit to the installation plate and move the unit to the right Vinyl tape and left until it is securely in place pas Connecting wires Make sure pipe does not move when
13. Press the button to set the operating mode Each time you press the Mode button the mode will change in order of Auto Cool Dry and Fan NOILINNA DISVg ZO Press the button to set the desired fan speed Auto Auto 2 Low Med High Cool Auto Low lt 2 Med BD High Dry Auto Fan mN Low Py Med Py High button to adjust the temperature Temperature doesn t display If you press Temp button it will decrease or increase by Auto BA ngn ngn n gnn An 1 C and remote display indicates 1 2 1 2 Cool You can adjust the set temperature by 1 C within the range of 16 C 31 C Dry Temperature adjustment is not possible Fan Temperature adjustment is not possible English 15 TCL ODM CO IB amp IM_EN indd 15 2014 11 19 2A 9 40 41 Airflow direction control Adjust the air flow direction properly otherwise it might cause discomfort or cause uneven room temperatures Adjust the vertical louver using the remote controller Vertical air flow gt Press the Vertical air swing gt button on the remote controller Air swing indicator will be on the remote controller display and air flow blades move up and down continuously to circulate the air gt Press the Vertical air swing gt button on the remote controller again to keep the air flow direction in a constant position gt Ifyou adjust the vertical air flow blade manually i
14. it is operating gt Turning the air conditioner off and then on again with the circuit breaker may cause a spark and result in electric shock or fire After unpacking the air conditioner keep all packaging materials well out of the reach of children as packaging materials can be dangerous to children P If achild places a bag over its head it may result in suffocation English 6 TCL ODM CO IB amp IM_EN indd 6 2014 11 19 2A 9 40 39 G Donottouch the air flow blade with your hands or fingers during the heating operation gt This may result in electric shock or burns Do not insert your fingers or foreign substances into the air inlet outlet of the air conditioner gt Take special care that children do not injure themselves by inserting their fingers into the product Do not strike or pull the air conditioner with excessive force P This may result in fire injury or problems with the product NOILIVJdVd3yd LO Do not place an object near the outdoor unit that allows children to climb onto the machine P This may result in children seriously injuring themselves Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people P Since this may be dangerous due to a lack of oxygen Open a window at least once an hour If any foreign substance such as water has entered the appliance cut off the power supply and contact the nearest service center gt Failing to do so may result i
15. the SET button within 10 seconds after setting the time Therefore check for the Off indicator on the remote controller display and the Timer indicator on the indoor unit display Cancel P Press the Timer button again Remote controller display English 18 TCL ODM CO IB amp IM_EN indd 18 2014 11 19 2A 9 40144 TCL ODM CO IB amp IM_EN indd 19 good sleep mode When the air conditioner is operating in Auto Cool mode 1 Press the amp button the air conditioner operates in good sleep mode indicator will be displayed on the remote controller display and amp indicator on the indoor unit display Fan speed will be adjusted automatically gt Timer Fast Ginsle S J Usery amp J se gt Cancel Press the amp button again Additional options available ingood sleepmode You can adjust the set temperature by 1 C within the range of 16 C 31 C in Cool mode If the MODE Power button is selected while g00d sleep function is on corresponding function will be cancelled e Recommended set temperature is between 25 C 27 C for cooling Ifthe set temperature is too low you may feel cold during sleep or catch a cold English 19 2014 11 19 NOILDNN4 GJDNVACV 0 2A 9 40145 Using the Fastfunction You can set the Fast function to provide fast and powerful cooling When the air conditioner is operating in Cool Dry
16. you install the indoor unit on Drain hose T caution a installation plate 5 Wrap the rest of the pipe with vinyl tape 6 Attach the pipe to the wall using clamps optional Fixing the outdoor unit in place Install the outdoor unit in level on a stable base to help avoid the generation of noise and vibration especially when installing the unit close to a neighbor If you install the outdoor unit in a place exposed to strong winds or at a height fix it to an appropriate support wall or ground 1 Place the outdoor unit as indicated on the top of the unit to let the discharged air out properly 2 Fix the outdoor unit in level to an appropriate support using anchor bolts Model X Y 09 375 256 3 Ifthe outdoor unit is exposed to strong winds install shield plates around the OKT DEK 439 278 outdoor unit so that the fan can operate correctly B Secure the rubber leg to help prevent the generation of noise and vibration NOTE Outdoor unit installed on the wall by rack Ensure the wall will be able to suspend the weight of rack and outdoor unit 9 Install the rack close to the column as much as possible Install proper grommet in order to help reduce noise and residual vibration transferred by outdoor unit towards wall Designed to cut off residual vibration from outdoor unit to rack not supplied with product
17. 0 IO Un B ow NO Fe 80g m GB T1804 c A5 BLACK BRR ERG SAN ERW TEN MEERE RAS ASA WArial y Al 8mm 757 JM XXXXXXXXXXXX JM XXXXXXXXXXXX A JM XXXXXXXXXXXX B ROR ARE AE s wawo man TARA 211337691 a masos aseje a aime Te RTE eel axes s He m et eae poses eleaw a ara ne fuse woes een aapea ferea Hre rE M AR JR Series imagine the possibilities Thank you for purchasing this Samsung product lt TCL ODM CO IB amp IM_EN indd 49 2014 11 19 2 9 40 56 Features ofyour new air conditioner Cool Summer Offer On those hot sweltering summer days and long restless nights there is no better escape from the heat than the cool comforts of home Your new air conditioner brings an end to exhausting hot summer days and lets you rest Beat the heat with your own air conditioner this summer j Fast cooling If you want the strong and cool air just select Fast function It will get you the strongest air Single User Use Single User function when you are alone at home This function will set the tempe
18. 0 49 Choosing the installation location Outdoor Unit Where itis not exposed to strong wind Well ventilated and dustless places Where possible keep out of sunlight and rain Where neighbors are not annoyed by operation sound or hot air Solid wall or support that prevents vibration and is strong enough to hold the product weight Where there is no risk of flammable gas leakage When installing the unit at a high place be sure to fix the unit legs 3 m or more away from the TV or radio to prevent the screen from being distorted or noise from being generated Install the unit horizontally Place where drained water does not become any problem Place with no plants especially climbing plants and where small animal can not access vY VY VY vV V V V V VF V V Outdoor unit should not be place higher than 2 4 m or directly under eaves for accessibility for service and OH amp S reasons A e Avoid the following places to prevent malfunction of the unit caur on Where there is machine oil Salty environment such as seaside areas Where sulfide gas exists Other special atmosphere areas 150 mm or more a j lt gt 150 mm or more Wrap the refrigerant pipes and the drain hose with the absorbent pad and vinyl tape Refer to page 45 for further details 15 m as maximum pipe lengt and 3 m as minimum pipe length CAUTION t will reduce noise and vibrati 15 meters maximum total pipe length 5 meters m
19. 9 QA 9 40 39 Checking the name of the parts Your air conditioner may slightly look different from illustration shown below depending on your model Main parts Front panel Air intake Air filter Air flow blade up and down Air flow blade left and right Remote controller receiver x OO Power button Timer indicator good sleep indicator Cooling indicator English 11 TCL ODM CO IB amp IM_EN indd 11 2014 11 19 NOIL2Nndj DIS9V9 ZO QN 9 40 40 Checking the remote controller Point the remote controller towards the remote controller receiver of the indoor unit e When you properly press the button on the remote controller you will hear beep sound from the indoor unit and a transmit indicator T appears on the remote controller display Remote controller buttons Vertical air swing Activate Deactivate vertical air flow blade movement automatically Mode Set one of the 4 operating modes No Heat mode function Power Turn on off the air conditioner Temp Fanav Increase Decrease the Adjust the fan speed temperature by 1 C Fast good sleep Turn on off Fast function Set the good sleep mode on off Timer Single User Turn on off Timer function Turn on off the Single User function which reduces energy usage while operating in cool mode SET i Set on off Timer time Directional lt gt Move through the Timer to make a selection N Make su
20. Compatibility Directive 2004 108 EC of the European Union gt The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the Operating limits table included in the manual shall immediately invalidate the warranty gt The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Do not use the units if damaged If problems occur switch the unit off and disconnect it from the power supply In order to help prevent electric shocks fires or injuries always stop the unit disable the protection switch and contact SAMSUNGSs technical support if the unit produces smoke if the power cable is hot or damaged or if the unit is very noisy gt Always remember to inspect the unit electric connections refrigerant tubes and protections regularly These operations should be performed by qualified personnel only gt The unit contains moving parts which should always be kept out of the reach of children Do not attempt to repair move alter or reinstall the unit If performed by unauthorized personnel these operations may cause electric shocks or fires gt Donot place containers with liquids or other objects on the unit All the materials used for the manufacture and packaging of the air conditioner are recyclable gt The packi
21. Fan mode 1 Pressthe button Fast indicator oppears and Fast function begins Fan speed will be adjusted in high speed When the Fast function is on vertical air swing can be adjusted Cancel Press the button again e While the Fast function is activing good sleep function can t be operated e If the Single use Temp Fana w function is selected while Fast function is on corresponding function will be cancelled NOTE Remote controller display English 20 TCL ODM CO IB amp IM_EN indd 20 2014 11 19 2A 9 40 46 Using the Single user function This function will reduce the energy usage while the air conditioner is operating in Cool mode When the air conditioner is operating in Cool mode 1 Pressthe button Single user indicator oppears and Single user function begins Cancel p Prass the button again lt YW Single user function is only available in Cool mode NOTE If the Fast function is selected while Single user function is on corresponding function will be cancelled NOILINN4 GADNVACV 0 TORE Ifthe Single User function is activing good sleep function also can be selected m I a Single User Remote controller display Additional options available in Single user function You can adjust the set temperature by 1 C within the range of 16 C 31 Cin Cool mode lt p Auto Low m Med m High
22. again Remote controller display Additional options available in On time You can select from Auto Cool Dry Fan You can set the fan speed after selecting Auto Cool Fan mode You can set the temperature after selecting the operation mode Temperature adjustment is available when Auto Cool mode is selected After 3 seconds from the completion of the On timer setting only On indicator will remain displayed on the remote controller display of Auto Dry Fan mode If you press the Power button on the indoor unit after setting the On timer from the remote controller Timer indicator on the indoor unit display will disappear and the On timer will be cancelled English 17 TCL ODM CO IB amp IM_EN indd 17 2014 11 19 2A 9 40144 Setting the On Off timer Setting the Off timer When the air conditioner is on 1 Press the Timer button Off indicator will keep blinking and you can set the time 2 Press the button to set the time Timer You can set the time in half hour unit from 30 minutes 0 5 on the display 3 hours and hour unit from 3 24 hours Time can be set from minimum 30 minutes to maximum 24 hours 3 Press the SET button to complete the Off timer setting Off indicator and the set time of the timer will be displayed on the remote controller display and Timer indicator will be displayed on the indoor unit display Off timer setting will be cancelled if you don t press
23. al products operate by the remote controller call your nearest contact center NOTE English 13 TCL ODM CO IB amp IM_EN indd 13 2014 11 19 2A 9 40 40 Basicfunction Basic operation is an operation mode that can be selected by pressing the Mode button Auto In Auto mode the air conditioner will automatically set the temperature and fan speed depending on the room temperature e Ifyou press Temp button it will decrease or increase by 1 C and remote display indicates 1 2 1 2 When remote controller arrived to the set limit it can t be operate again though the indoor unit can receive the singnal Cool In Cool mode the air conditioner will cool your room You can adjust the temperature and the fan speed to feel cooler in hot season If current outside temperature is much higher than the selected indoor temperature it may take time to bring the inner temperature to the desired coolness When the Cool mode is set cooling indicator will be displayed on the indoor unit display Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air Dry mode makes the air feel refreshing in a humid climate Fan Fan mode can be selected to circulate your room Fan mode will be helpful to refresh the stale air in your room English 14 TCL ODM CO IB amp IM_EN indd 14 2014 11 19 2A 9 40 41 Basicfunction Press the button to turn on the air conditioner
24. applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs The units components must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is not observed as indicated into the Installation Manual the cost necessary to reach and repair the unit in safety as required by current regulations in force with slings trucks scaffolding or any other means of elevation won t be considered in warranty and charged to end user NOILWTIVLSNI SO Power supply line fuse or circuit breaker gt Always make sure that the power supply is compliant with current safety standards Always install the air conditioner in compliance with current local safety standards Always verify that a suitable grounding connection is available Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines Always verify that the cut off and protection switches are suitably dimensioned Verify that the air conditioner is connected to the power supply in accordance with the instruc
25. aximum total pipe height N 74 The appearance of the unit may be different from the diagram depending on the model English 30 TCL ODM CO IB amp IM_EN indd 30 2014 11 19 2A 9 40 49 Space Requirements for Outdoor Unit When installing 1 outdoor unit Figure Description Top view Side view Air intake NOILYTIVLSNI SO Air outlet 4 Air intake Air outlet A IN 4 Air flow direction f Unit mm When the air outlet is opposite the When the air outlet is towards the When 3 sides of the outdoor unit are wall wall blocked by the wall U LEIA EID In a v U 2 A 5 o S a ts 5 og oO O m m S Y I a S gt ni gt lt q 150 or more 600 or more The upper part of the outdoor unit The upper part of the outdoor unit When the walls are blocking front and the air outlet is towards the wall and the air outlet is opposite the and the rear side of the outdoor unit wall z v OTL Ton N E 2 U S 5 2000 or more 5 A mE g D gt a A 1500 or more N When installing more than 1 outdoor unit Unit mm When the air outlet is towards the wall When 3 sides of the outdoor unit are blocked by the wall U U U v TE LI J oo 5 5 y u 5 PEALAEL r t oO gt gt gt gt 300 or more 600 ormore 600 or more 600 or more English 31 TCL ODM CO IB amp IM_EN indd 31 2014 11 19 2A 9 40 50 Choosing
26. e CAUTION outdoor unit heat exchanger Heat exchanger Illustration may differ slightly depending on the models English 22 TCL ODM CO IB amp IM_EN indd 22 2014 11 19 2 9 40 48 Removing the Air filter 1 Open the front panel following the direction of the arrow SyI3H1O tO 2 Keeping the front panel raised with one hand take out the air filter with the other hand 3 Install the air filter back into position 4 Close the front panel English 23 TCL ODM CO IB amp IM_EN indd 23 2014 11 19 amp 9 40 48 Cleaning the air conditioner Cleaning the air filter Washable foam based air filter captures large particles from the air The filter is cleaned with a vacuum or by hand washing Remove the Air filter from the main body Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy rinse it with running water Insert the Air filter back in its original position Dry the Air filter in a ventilated area Clean the air freshening filter at least once a month NOTE Ifthe Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in a well ventilated area Ifthe filter is soiled with oil it can be washed with warm water not exceeding 45 C Leave to dry in a cool and dry place English 24 TCL ODM CO IB amp IM_EN indd 24 2014 11 19 amp
27. e Nem kgfecm 26 35 mm 14 18 140 180 E o 09 52 mm 34 42 350 430 12 70mm 49 61 500 620 Indoor outlet pipe Connecting pipe 15 88 mm 68 82 690 830 Excessive torque can be cause of gas leakage If extending pipe by welding brazing please ensure nitrogen is NGTE used during welding brazing process The joint must be accessible and serviceable NOILWTIVLSNI SO 7 For further details on how to connect to the outdoor unit and evacuate the air refer to page 42 43 Tighten the flare nut with torque wrench according to specified method caution __ the flare nut is over tightened the flare may break and cause refrigerant gas leakage English 39 2014 11 19 QA 9 40 52 Installing and connecting the drain hose of the indoor unit When installing the drain hose for the indoor unit check if condensation draining is adequate When passing the drain hose through the 65 mm hole drilled in the wall check the followings Indoor unit Drain hose The drain hose must NOT slant upwards 0 0 5cm less AF Ditch Do not place the end of the drain hose in a hollow Keep a clearance of at least 5 cm between the end of the drain hose and the ground 1 Correct connection LA AWV The end of the drain hose must NOT be placed under water 2 Incorrect connection S ao 0 00 00 ooo j ET A Lt
28. emperature Check if you have selected Dry Fan Fast mode In these adjustment is not modes set temperature is set to auto and you cannot working adjust the temperature Cool air does not Check if the set temperature is higher during Cool mode come out of theair than the current temperature Press the Temp or button conditioner on the remote controller to change the set temperature Check if the Air filter is blocked by dirt If there is a lot of dust on the Air filter cooling performance may decrease Clean them frequently Check if the outdoor unit is covered or installed near the obstacle Take the cover off and take the obstacle away Check if the air conditioner is operating in defrost mode When the ice formed in winter or the outdoor temperature is too low the air conditioner operates in defrost mode automatically In defrost mode indoor fan stops and warm air does not come out If the doors or windows are open it may cause bad cooling performance Close the doors and windows Check if the air conditioner has just been turned on after stopping cooling operation In this case just a fan will run to protect the outdoor unit compressor e Check if the pipe length is too long When the pipe length exceeds maximum allowable pipe length cooling performance may decrease English 26 TCL ODM CO IB amp IM_EN indd 26 2014 11 19 2A 9 40 49 PROBLEM SOLUTION Fan Speed e Check if you have selected Dr
29. erature from the outdoor difference It is normal unit piping connection English 27 TCL ODM CO IB amp IM_EN indd 27 2014 11 19 2 amp 9 40149 Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety ofthe equipment e Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components e Verify that installation and testing operations are performed by qualified personnel e Verify that the air conditioner is not installed in an easily accessible area General information gt Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation For maximum safety installers should always carefully read the following warnings gt Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred gt This manual explains how to install an indoor unit with a split system with two SAMSUNG units The use of other types of units with different control systems may damage the units and invalidate the warranty The manufacturer shall not be responsible for damages arising from the use of non compliant units gt This product has been determined to be in compliance with the Low Voltage Directive 2006 95 EC and the Electromagnetic
30. g a thunder lightning storm cut the power at the circuit breaker gt Failing to do so may result in electric shock or fire FOR USING A WARNING ifthe appliance is flooded please contact your nearest service center P Failing to do so may result in electric shock or fire If the appliance generates a strange noise a burning smell or smoke cut off the power supply immediately and contact the nearest service center gt Failing to do so may result in electric shock or fire In the event of a gas leak such as propane gas LP gas etc ventilate immediately without touching the power line Do not touch the appliance or power line gt Do not use a ventilating fan B A spark may result in an explosion or fire To reinstall the air conditioner please contact your nearest service center gt Failing to do so may result in problems with the product water leakage electric shock or fire P A delivery service for the product is not provided If you reinstall the product in another location additional construction expenses and an installation fee will be charged Especially when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to the salt in the air please contact your nearest service center Do not touch the circuit breaker with wet hands P This may result in electric shock Do not turn the air conditioner off with the circuit breaker while
31. gt ifthe voltage frequency rated current condition is different it may cause fire The installation of this appliance must be performed by a qualified technician or service company P Failing to do so may result in electric shock fire explosion problems with the product or injury and may also void warranty on the installed product Install a Isolation Switch next to the Air Conditioner but not on the panels of the Air Conditioner and circuit breaker dedicated to the air conditioner gt Failing to do so may result in electric shock or fire Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed gt Failing to do so may result in electric shock fire explosion problems with the product English 4 TCL ODM CO IB amp IM_EN indd 4 2014 11 19 2A 9 40 39 O Do not install this appliance near a heater inflammable material Do not install this appliance in a humid oily or dusty location in a location exposed to direct sunlight and water rain drops Do not install this appliance in a location where gas may leak P This may result in electric shock or fire Never install the outdoor unit in a location such as on a high external wall where it could fall P Ifthe outdoor unit falls it may result in injury death or property damage This appliance must be properly grounded Do not ground the appliance toa gas pipe plastic water pipe or telephone line P Failure to do so may result in electric shoc
32. k fire and explosion P Make sure to use a socket outlet with ground NOILIVJVd3yd LO FOR INSTALLATION CAUTION Install your appliance on a level and hard floor that can support its weight P Failing to do so may result in abnormal vibrations noise or problems with the product Install the draining hose properly so that water is drained correctly gt Failing to do so may result in water overflowing and property damage Avoid adding drain to waste pipes as odours may arise in the future When installing the outdoor unit make sure to connect the draining hose so that draining is performed correctly The water generated during the heating operation by the outdoor unit may overflow and result in property damage In particular in winter if a block of ice falls it may result in injury death or property damage FOR POWER SUPPLY WARNING Whenthe circuit breaker is damaged contact your nearest service center Do not pull or excessively bend the power line Do not twist or tie the power line Do not hook the power line over a metal object place a heavy object on the power line insert the power line between objects or push the power line into the space behind the appliance gt This may result in electric shock or fire English 5 TCL ODM CO IB amp IM_EN indd 5 2014 11 19 2A 9 40 39 Safety precautions FOR POWER SUPPLY A CAUTION When not using the air conditioner for a long period of time or durin
33. linder with siphon Cylinder without siphon Charge the refrigerant standing the gt Charge the refrigerant turning the cylinder cylinder upright 3 upside down IfR 410A refrigerant is charged with gas the composition of the charged refrigerant changes and the characteristics of the equipment vary During the measuring operation of refrigerant quantity added use electronic scales If cylinder doesn t have syphon upset it English 43 TCL ODM CO IB amp IM_EN indd 43 2014 11 19 2A 9 40 54 Performing the gas leak tests Make sure to check for gas leaks before completing the installation process connecting the assembly pipe and hose between indoor unit and outdoor unit insulating the cables hose and pipe and fixing the indoor unit to the installation plate Test part for outdoor unit Test part for indoor unit Tightening torque for body cap gt Before inspecting the leakage use a torque wrench Refer to the table to close the cap for the service valve Comply with a tightening torque for each size of the diameter and tighten the cap firmly to prevent any leakage gt To check for any possible leakage insert inert gas into Spindle the pipes connected to indoor outdoor units and l DD pnd check the connection part of the indoor outdoor units Charging 7 m aaa with soap lather or liquid for leakage test core my zzz g f KARIN
34. mful to humans Do not apply a strong impact to the remote controller and do not disassemble the remote controller Do not touch the pipes connected with the product P This may result in burns or injury Do not use this air conditioner to preserve precision equipment food animals plants or cosmetics or for any other unusual purposes P This may result in property damage Avoid directly exposing humans animals or plants from the air flow from the air conditioner for long periods of time P This may result in harm to humans animals or plants English 8 TCL ODM CO IB amp IM_EN indd 8 2014 11 19 2A 9 40 39 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance NOILIVJVd3yd LO FOR CLEANING AWARNING Do not clean the appliance by spraying water directly onto it Do not use benzene thinner or alcohol to clean the appliance P This may result in discoloration deformation damage electric shock or fire Before cleaning or performing maintenance cut off the power supply and wait until the fan stops P Failing to do so may result in electric shock or fire FOR CLEANING NCAUTION Q Take care when cleaning
35. n electric shock or fire Q Do not attempt to repair disassemble or modify the appliance yourself P Do not use any fuse such as cooper steel wire etc other than the standard fuse P Failing to do so may result in electric shock fire problems with the product or injury English 7 TCL ODM CO IB amp IM_EN indd 7 2014 11 19 2A 9 40 39 Safety precautions FOR USING CAUTION Donot place objects or devices under the indoor unit gt Water dripping from the indoor unit may result in fire or property damage example electrical appliances Check that the installation frame of the outdoor unit is not broken at least once a year P Failing to do so may result in injury death or property damage Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency GD Do not stand on top of the appliance or place objects such as laundry lighted candles lighted cigarettes dishes chemicals metal objects etc on the appliance P This may result in electric shock fire problems with the product or injury Do not operate the appliance with wet hands P This may result in electric shock Do not spray volatile material such as insecticide onto the surface of the appliance As well as being harmful to humans it may also result in electric shock fire or problems with the product Do not drink the water from the air conditioner gt The water may be har
36. nd trial operation pp 46 Pump down procedure when removing the product pp 46 How to connect your extended power cables pp 47 English 3 TCL ODM CO IB amp IM_EN indd 3 2014 11 19 2 9 40 38 Safety precautions Before using your new air conditioner please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance Because the following operating instructions cover various models the characteristics of your air conditioner may differ slightly from those described in this manual If you have any questions call your nearest contact center or find help and information online at www samsung com Important safety symbols and precautions Hazards or unsafe practices that may result in severe A WARNING personal injury or death Hazards or unsafe practices that may result in minor A CAUTION personal injury or property damage 0 Follow directions Cut off the power supply D Do NOT attempt O Do NOT disassemble Make sure the machine is grounded to prevent electric shock FOR INSTALLATION WARNING Q Use the power line with the power specifications of the product or higher and use the power line for this appliance only In addition do not use an extension line P Extending the power line may result in electric shock or fire gt Do not use an electric transformer It may result in electric shock or fire
37. ng material and exhaust batteries of the remote controller optional must be disposed of in accordance with current laws gt The air conditioner contains a refrigerant that has to be disposed of as special waste At the end of its life cycle the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely Installing the unit IMPORTANT When installing the unit always remember to connect first the refrigerant tubes then the electrical lines Always disassemble the electric lines before the refrigerant tubes gt Upon receipt inspect the product to verify that it has not been damaged during transport If the product appears damaged DO NOT INSTALL it and immediately report the damage to the carrier or retailer if the installer or the authorized technician has collected the material from the retailer English 28 TCL ODM CO IB amp IM_EN indd 28 2014 11 19 2A 9 40 49 After completing the installation always carry out afunctionaltest and provide the instructions on how to operate the air conditioner to the user Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires explosions or injuries To help prevent injury when accidentally touching the indoor unit fan install the indoor unit at least 2 5 m above the floor The air conditioner should be used only for the
38. ngth of the pipe can be Extended up to see table page 30 Shorten up to see page 30 If you need a pipe longer than 5 meters CAUTION You must add refrigerant to the pipes otherwise the indoor unit may freeze 1 Make sure that you have all the required tools pipe cutter reamer flaring tool and pipe holder 2 Ifyou want to shorten the pipe cut it using a pipe cutter ensuring that the cut edge remains at 90 with the side of the pipe see below examples of correct and incorrect cut edges 90 3 To prevent a gas leak remove all burrs at the cut edge of the pipe using a reamer IN Facethe pipe down while removing the burrs to make sure that burrs do not get in to the pipe CAUTION English 38 TCL ODM CO IB amp IM_EN indd 38 2014 11 19 2A 9 40 52 TCL ODM CO IB amp IM_EN indd 39 Put a flare nut slightly into the pipe and modify the flare D ee Outer Diameter D Depth A Flaring Size B SE A 4542 06 35 mm 1 3mm 8 7 9 1 mm a Br 09 52 mm 1 8mm 12 8 13 2 mm 2 012 70 mm 2 0 mm 16 2 16 6 mm a Vf 015 88 mm 2 2mm 19 3 19 7 mm Pipe Flare Check if you flared the pipe correctly see examples of incorrectly flared pipes below Correct Inclined Damaged Cracked Uneven Surface Thickness Align the pipes to connect them easily Tighten the flare nuts first with your hands and then with a torque wrench applying the following torque Havent Outer Diameter oral
39. rature range limit to help you save energy while the air conditioner is operating in Cool mode good sleep function good sleep function will allow you to have deep good night s sleep by adjusting the temperature fan speed and air flow direction English 2 TCL ODM CO IB amp IM_EN indd 2 2014 11 19 2 9 40 38 Contents Preparation 5 4 Checking belore te me 10 Basic function Checkingthename o he oe Or od ee RE 11 Checking the remote Contoller ee ee Eee 12 a T a e eo a ea ee 14 Aitlow direction contol 4 1oadesseantereineeiaeerseshesouecreaaaupnieeners 16 Advanced Function SELLING CHE ON ON EINER ee as a een ee een ner ee re Rare 17 good sleepimode ee er ee EEE Ehe 19 SEE 20 Using the SINGIGUSEl TUNCHON sauer each rain 21 Others cleaning the alk SONNE 0 euere 22 Maintaining the air conditioner pp 25 TouBleshnootme eo 26 Installation E DIE ne ee ee er ee re ee eh 28 Choosing the installation location sen nen seen sera 29 ACEessolles 0 0 EN EBENE E E E NS 32 FIRING CNS instalation DIE 34 Connecting the assembly cable nt 35 Installing and connecting the assembly pipe of the indoor unit pp 37 Evactauind ie INDONESIEN 38 Cutting OF extending the pple sey vany ENESENN EPNER EAE EAEN ASAS 38 Installing and connecting the drain hose of the indoor ynit 40 Evac ating the connected ples ee 42 Performing the gas leak tests a see TREE 44 Fixing the indoor unit in place pe 45 FIXING the outdoor dnin nl 45 Final check a
40. re that the water does not get to the remote controller CAUTION English 12 TCL ODM CO IB amp IM_EN indd 12 2014 11 19 2A 9 40 40 Remote controller display Operation mode indicator No Heat mode function This function is not NY Low battery indicator available in this model Fein e Cot sw ih Set Time for Timer option indicator good sleep indicator Du u HR Transmit indicator Fan speed indicator Vertical air swing indicator NOILDNNIDISVI ZO Fast indicator Single User indicator Low Battery warning Inserting the batteries When the battery is exhausted Z4 will be displayed in the 1 Push the lever as arrow indicates on the rear side of the remote controller display When the icon appears change remote controller and pull up the batteries The remote controller requires two 1 5 V AAA 2 Insert two AAA batteries type batteries Check and match the and signs accordingly Make sure Storing the remote controller you have inserted the batteries in correct position 3 Close the cover by place it back to its original position When you do not use the remote controller for long time You should hear click sound when the cover is locked properly remove the batteries from the remote controller and store it The signal may not be received properly if electronic flourescent lamps such as inverter flourescent lamps are operating in the same space If other electric
41. ring terminal socket may become a fire hazard due to overheating of the electrical CAUTION contact during a wiring work When you install the unit make first refrigerant connections and then electrical connections Connect the air conditioner to grounding system before performing the electrical connection If unit is uninstalled first disconnect electrical cables then refrigerant connections English 35 TCL ODM CO IB amp IM_EN indd 35 2014 11 19 2A 9 40 51 Connecting the assembly cable If the outdoor unit is more than 5 meters away from the indoor unit you must extend the cable The maximum length of the cable is 15 meters 1 Extend the assembly cable if necessary IN Do not connect two or more different cables to extend the length It may cause fire CAUTION 2 Open the cover panel 3 Remove the screw securing the connector cover 4 Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals Refer to the picture below B Each wire is labeled with the corresponding terminal number NOTE Da 6 7 8 9 Pass the other end of the cable through the 65 mm hole in the wall Close the connector cover by tightening the screw carefully Close the cover panel Remove the terminal board cover on the side of the outdoor unit Connect the cables to the terminals as seen in the picture B e Each wire is labeled with the corresponding terminal number NOTE
42. s seen in the picture 0952 mm 34 42 350 430 4 Open the valve of the low pressure side of manifold gauge counterclockwise 012 70mm 4961 500 620 015 88mm 68 82 690 830 5 Evacuate the air in the connected pipes using the vacuum pump for about 15 minutes Manifold gauge gt Make sure that pressure gauge shows 0 1 MPa 76 cmHg after about 10 minutes This procedure is very important to avoid a gas leak Valve As gt Close the valve of the low pressure side of manifold gauge clockwise BEE Gas service port U Turn offthe vacuum pump lt Low pressure gt gt Check for 2 minutes if there is any pressure change N gt Remove the hose of the low pressure side of manifold gauge 6 Seta valve cork of liquid and gas service port to the open position P A i i Liquid service port Pump Adding Refrigerant lt High pressure gt Backward flowing prevention Add refrigerant charge according to table below If you use a pipe longer than 5 m 20 g of refrigerant R 410A must be added for each extra meter If you use a pipe shorter than 5 m The evacuate time is normal Refer to the Service Manual for further details The remaining air in the Refrigeration cycle which contains moisture may cause malfunction on the compressor caution Always contact the service center or a professional installation agency for product installation English 42
43. s work properly FR 4 Pressthe Power button to stop the operation Temp e When you complete the installation successfully hand over this manual to the user for storage in a handy and safe NOTE Place Pump down procedure when removing the product _ 1 Turn on the air conditioner and select Fast Cool mode Please let the compressor run for more than 5 minutes If the compressor does not operate for more than 5 minutes due to protection control wait about 2 minutes and then carry out the next procedure 2 Release the valve caps on High and Low pressure side 3 UseL wrench to close the valve on the high pressure side 4 Approximately 2 minutes after close the valve on the low pressure side 5 Stop operation of the air conditioner by pressing the Power button on the indoor unit or remote controller 6 Disconnect the pipes English 46 TCL ODM CO IB amp IM_EN indd 46 2014 11 19 2A 9 40 55 How to connect your extended power cables Items to prepare compressor and insulation tape should be prepared by an installation technician Crimping pliers Connection sleeve mm Insulation tape Contraction tube mm O LxOD MH 14 20x 7 0 HxOD Width 18 mm 50x 8 0 LxOD gt 1 As shown in the figure peel off the shields from the rubber wire Unit mm of the power cable Power cable provided by us Peel off 20 mm of the wire shields of the tube installed already NOILVTIVLSNI SO
44. t and evacuate the air refer to page 42 43 The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test NOTE refer to page 44 for further details Tighten the flare nut with torque wrench according to specified method caur on __ the flare nut is over tightened the flare may break and cause refrigerant gas leakage DO NOT WALL UP THE PIPE CONNECTION All refrigerant pipe connection must be easy accessible and serviceable NOILWTIVLSNI SO English 37 TCL ODM CO IB amp IM_EN indd 37 2014 11 19 QA 9 40 52 Evacuating the indoor unit Theindoor unit is supplied with inert gas nitrogen Before installing the unit check if nitrogen gas flow out of indoor unit If this one isn t true DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit 1 Unscrew the caps at the end of each pipe gt All inert gas exhausts from the indoor unit To prevent dirt or foreign substances from getting into the pipes note during installation do NOT remove the caps completely until you are ready to connect the pipes mono e The remaining air in the Refrigeration cycle which contains moisture caution May cause malfunction on the compressor Always contact the service center or a professional installation agency for product installation caps Pipes Unscrew the Cutting or extending the pipe The le
45. t may not close completely when you turn off the air conditioner Horizontal air flow Make sure one of the blade pin lever that stick out of the air flow blades are not broken gt Move the deflector rod manually to adjust the air flow in the direction you prefer Be extremely careful with your fingers while adjusting the Horizontal Blade pin lever air flow direction There is a potential risk of personal injury when the unit is mishandled English 16 TCL ODM CO IB amp IM_EN indd 16 2014 11 19 2A 9 40 43 Setting the On Off timer Setting the On timer When the air conditioner is off 1 Press the Timer button On indicator will keep blinking and you can set the time 2 Pressthe button to set the time You can set the time in half hour unit from 30 minutes 0 5 on the display 3 hours and hour unit from 3 24 hours Time can be set from minimum 30 minutes to maximum 24 hours 3 Press the SET button to complete the On timer setting On indicator and the set time of the timer will be displayed on the remote controller display and the Timer indicator will be displayed on the indoor unit display On timer setting will be cancelled if you don t press the SET button within 10 seconds after setting the time Therefore check for the On indicator on the remote controller display and the Timer indicator on the indoor unit display NOILINN4 GADNVACV 0 Cancel P Press the Timer button
46. the installation location Unit mm When the walls are blocking front and the rear side of the outdoor When the upper part of the outdoor unit and units the air outlet is opposite the wall LOAF IAP ITAL TAD TIT ELI i v v v SS 2 O v UV gt 2 SoS a 600 or more 600 or more 2 a When front and rear side of the outdoor unit is towards the wall Le St 300 or more _ 500 or more ve 1500 or 600 or 3000 or 3000 or 200 or more more more more more e If installation is done in inappropriate space unit may generate sound and cause bad effect on the product caution Installation must be done in level and in a place where vibration will not cause any effect Accessories The following accessories are supplied with the air conditioner A The number of each accessory is indicated in parentheses NOTE Accessories in the indoor unit case Installation Plate 1 Remote controller 1 Nut 2 Batteries for 09 12 Remote controller 2 GS 2 User s amp Installation Manual English 32 TCL ODM CO IB amp IM_EN indd 32 2014 11 19 2A 9 40 50 Accessories in the outdoor unit case Rubber Legs 4 NOILYTIVLSNI SO Optional accessories The following connection accessories are optional If they are not supplied you should obtain them before installing the air conditioner Insulated Ins
47. the surface of the heat exchanger of the outdoor unit since it has sharp edges P This should be done by a qualified technician please contact your installer or service center Q Do not clean the inside of the air conditioner by yourself P For cleaning inside the appliance contact your nearest service center gt When cleaning the internal filter refer to the descriptions in the Cleaning the air conditioner section P Failure to do may result in damage electric shock or fire English 9 TCL ODM CO IB amp IM_EN indd 9 2014 11 19 2A 9 40 39 Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use Mode Indoor temperature Outdoor temperature Indoor humidity Cooling 16 C 31 C 16 C 43 C Relative humidity 80 or less Dry 16 C 31 C 16 C 43 C gt Ifthe air conditioner operates in cooling mode for long period of time in high humidity area dew may be formed Maintaining your air conditioner Internal protections via the unit control system gt This internal protection operates if an internal fault occurs in the air conditioner Type Description The air conditioner does not start operating immediately to help protect the compressor Protect compressor of the outdoor unit after it has been started TCL ODM CO IB amp IM_EN indd 10 English 10 2014 11 1
48. tions provided in the wiring diagram included in the manual Always verify that electric connections cable entry section of leads protections are compliant with the electric specifications and with the instructions provided in the wiring scheme Always verify that all connections comply with the standards applicable to the installation of air conditioners Choosing the installation location f indoor unit gt v vv vV vV V V For Wi Fi Air conditioner installation select indoor unit location near to wireless router In case Wi Fi signal strength weakened Smart APP may be disconnected depending on the Wi Fi signal strength Where airflow is not blocked Where cool air can be distributed throughout the room Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram Wall that prevents vibration and is strong enough to hold the product weight Out of the direct sunlight 1 m or more away from the TV or radio to prevent the screen from being distorted or noise from being generated As far away as possible from the fluorescent and incandescent lights so that the remote controller can be operated well A place where the air filter can be replaced easily Don t install directly above electronics equipment as leaking water may cause damage if not serviced eg Computers TV etc English 29 TCL ODM CO IB amp IM_EN indd 29 2014 11 19 2A 9 4
49. ulated Insulated Drain Hace 3 wire Assembly Pipe Assembly Pipe Assembly Pipe Rubber Legs 4 lanai tin 1 Assembly Cable 06 35 mm 1 09 52 mm 1 12 7 mm 1 g Vinyl Tapes 2 E If these accessories are supplied they will be in the accessory box NOTE Tools required for installation General Tools e Vacuum Pump Backward flowing prevention e Manifold Gauge e Stud Finder e Torque Wrench e Pipe Cutter e Reamer Pipe Bender e Spirit Level e Screw Driver e Spanner e Drill e LWrench e Measuring Tape Tools for test operations e Thermometer e Resistance Meter Electroscope English 33 TCL ODM CO IB amp IM_EN indd 33 2014 11 19 2A 9 40 51 Fixing the installation plate You can select the direction of the drain hose depending on where you want to install the indoor unit Therefore before fixing the installation plate to a wall or a window frame you must determine the position of the 65 mm hole through which the cable pipe and hose pass to connect the indoor unit to the outdoor unit When facing the wall the pipe and cable can be connected from the K Direction of pipe Right A Left B T sane ln e Underside_right C A B Rear_right or left D Y a y 1 Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65 mm so that it slants slightly downwards 09 12 RR 382 340 107
50. y good sleep mode In these adjustment is not mode fan speed is set to Auto and you cannot adjustthe amp working fan speed 9 Remote controller Check if your batteries are depleted D is not working e Make sure nothing is blocking your remote controller sensor e Check that there are strong lighting apparatus near the air conditioner Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves Timer function e Check if you press the Set button on the remote does not set controller after you have set the time The indicator Press the Power button or disconnect the power plug is blinking switch off the auxiliary power switch continuously If the indicator is still blinking contact the service center Odors permeate in Check if the appliance is running in a smoky area the room during Ventilate the room or operate the air conditioner in Fan operation mode for 1 2 hours We do not use smelly components in the air conditioner e Check the Drains have been cleared Regular Maintenance Error is indicated When an indoor unit indicator blinks contact the nearest service center Please ensure the error code is passed onto the service center when booking the service call Noise is generated Depending on the status of the air conditioner usage noise can be heard when refrigerant flow movement changes It is normal Water is dropping Water may be generated because of the temp
Download Pdf Manuals
Related Search
Related Contents
George Foreman GR44VTT Kitchen Grill User Manual Mode d`emploi du médicament ENDOTÉLON - Para DS-RX1 D:\DOCUME~1\CPUSERS\LOCALS~1\Temp\.aptcache\99924-2066 Gas Furnaces - Tasso Lake Heating Solutions 取扱説明書 - コスミックエンジニアリング Axor 40856000 User's Manual CoCreate Drafting 救急自動車仕様書 Copyright © All rights reserved.
Failed to retrieve file