1. 1 Open the front panel by pulling tabs on the lower right and left sides of the indoor unit 2 Detach the front panel by pulling it forwards Front panel 3 Hold the edge of the air filter under the front panel and pull to release 4 Remove all dust on the air filter with a vacuum cleaner or brush 5 When you finish insert the top of the filter into the slot and fix it to 5 tabs or 3 tabs of the grille 6 Clean the front panel with a damp cloth and mild detergent do NOT use benzene solvents or other chemicals 7 Reassemble the air filter and the front panel If you have not used the air conditioner for a while select the Fan mode for 3 to 4 hours to dry the inside of the air conditioner Cleaning Deodorizing and Bio filter Option To remove minute dust particles and odors deodorizing and Bio filter are installed in the air conditioner You should clean the filters every 3 months 1 Open the upper front grille by pulling the lower right and left tabs of the grille 2 Pull out the deodorizing and Bio filter 3 Wash the filters with clean water then dry them in the shade 4 Insert the filters into the original position Bio Filter You can change the position of filters with
2. WARNING ENGLISH DISPOSING THE UNIT gt Before throwing out the device it is necessary to pull back the battery cells and get rid of them safely for recycling reasons een WHEN INSTALLING gt When you need to dispose of the unit consult your dealer If pipes are removed incorrectly refrigerant may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environments gt Please recycle or dispose of the packaging material for this product in an environmentally responsible manner gt Install the air conditioner avoiding direct sunlight or heater especially water gt Install the outdoor unit so as to let the discharged air out properly Avoid a place that may disturb your neighbor by noise gt Install the drain hose to let the water run safely and correctly CAUTION REGARDING POWER SOURCE A gt Disconnect the circuit breaker gt Contact the service center or gt Contact the service center when you don t use the manufacturer if you wantto after turning off the air air conditioner for a long time repair the air conditioner conditioner if strange noise to save energy is heard burning smell or smoke blow DURING OPERATION gt Do not open the front grille gt Avoid cold and hot air gt Avoi
3. Heat Auto or Dry mode Check if the air filter is blocked by dirt Clean the air filter regularly Check if the there is cover on the outdoor unit or any obstacle Remove the cover or obstacle Check if you installed the air conditioner under direct sunlight The window or door may be opened Check if you turn on the air conditioner just now It takes about 3 minutes to cool or heat the room Check if the drain pipe is too long The fan speed is not adjusted In Auto or Dry mode the fan speed is selected automatically The remote control does Check if the battery is discharged Replace the battery not operate Check if the remote control sensor is blocked Check if the air conditioner is placed near strong light The Timer is not set Check if you pressed the 5 button after selecting time Odor is permeated in the Check if you use the air conditioner in smoky area or there is a smell room during operation Ventilate the room or select the Fan mode for 1 2 hours The indoor unit indicator Press the button to turn on the air conditioner again flashes Switch the circuit breaker off and switch on it again Strange sound is heard from The sound is heard when the refrigerant gas flow is changed depending the air conditioner on the use of the air conditioner When you press the button noise may be heard that the air conditioner sense the airflow blade Water drops from the outdoor unit connection pa
4. each other Front panel 5 Close the front grille Temperature and Humidity Ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use MODE OPERATING CONDITIONS IF OUT OF CONDITIONS Indoor temp 16 C 32 C A safety device will stop continuously the system Indoor humidity below 80 functioning COOL Condensation may occur on the indoor unit with Outdoor temp 10 C 43 C risk to have either water blow off or drops on the floor aT Indoor temp below 27 C A safety device will stop continuously the system Outdoor temp 15 C 24 C functioning Indoor temp 16 C 32 C A safety device will stop continuously the system Indoor humidity below 80 functioning DRY Condensation may occur on the indoor unit with Outdoor temp 10 C 43 C risk to have either water blow off or drops on the floor POWER SUPPLY Single phase rated voltage l apes minimum and maximum limit 198V min 264V max 3 Any damage occurs out of condition specified cannot be covered by product warranty If the system works continuosly outside of conditions its performace and reliability will be compromised ENGLISH Operating Recommenda ons When you use your air conditioner it is recommended
5. manufacturing and material in accordance with packaging materials used for your the local requirements newappliance are compatible i A with the environment and can be gt Be sure to insert the air filter recycled ENGLISH Name of Each Part The design and shape can be changed according to the model was Inlet 2 gt Room Temperature sensor Power On Off i button Airflow blade outlet Air filter under the panel mpizone E mode indicator mpizone Timer good sleep Lg mode indicator Auto cleaning indicator Set temperature amp Operation indicator room temperature nit AQVO9VB Series AQV12VB Series Air Inlet Rear Air Outlet Connection Valve Inside nit AQV18VB gt Series AQV24VB Series Air Inlet Rear Air Outlet Connection Valve Inside ENGLISH Remote Control Buttons and Display Airflow direction indicator Temperature settin rae P g Operating mode indicator Auto Cool Dry Fan Heat mpizone mode indicator ra me Rapid AutoSilenc Turbo function indicator Silence indicator Fan speed indicator Energy saving indicator Remote control Battery life indicator SOMO transmission indicator good sleep mode indicator Power On Off button Temperature adjustment buttons Mode selection button Auto Cool Dry Fan Heat Swing but
6. the indoor unit display appears and the Auto cleaning function runs gt When the air conditioner is turned on function runs after stopping the air conditioner operation Mode Operating time Auto cool Cool Dry 30 minutes Auto heat Heat Fan 15 minutes Auto cleaning operating time varies according to the mode you selected before the air conditioner turned off The Auto Cleaning indicator appears only on the indoor unit display When the air conditioner is turned on the Auto cleaning function runs after stopping the air conditioner operation Remote Control Set Temp Auto Distal on of C3 aye Control Panel ENGLISH Setting the On Timer You can set the On Timer to turn on the air conditioner automatically at the appointed time within a range of 30 minutes to 24 hours 1 Press the CD button Set Temp Auto Ju L It a7 amp 5 Down e 2 Press the 49 or 7 buttons until the desired time is displayed to set mpizone the On Timer You can set the time between 0 5 hour and 24 hours Off Down On Off Clean Mode OOO Result The remaining time is displayed The timer indicator stops blinking The selected mode and the temperature on the display disappear after 10 seconds The air conditioner turns on automatically at the appointed time and the On Timer setting disappears Up CC mpizone off Down O
7. to circulate the air according to various needs By adjusting the airflow direction the efficiency of the air conditioner can be increased Adjusting the Airflow Direction Vertically You can adjust the airflow direction vertically The outer airflow blade moves up and down to increase the efficiency of the cooling or heating operation F 1 Set Temp JAuto 1 Press the button until the required direction is set LI Result The outer blade is adjusted vertically Auto L c 2 Press the CO button again to move the blade up and down Q N automatically during operation Digitali On off EP 3 Press the CQ button again to stop the blade moving up and down Nota If you turn the air conditioner Then the blade Off is closed completely On set to the default position Adjusting the Airflow Direction Horizontally You can adjust airflow direction horizontally manually The inner blades with small fins move the air in the desired direction 1 Adjust the inner blades by moving them left or right Make sure do not touch the inner blades during operation It may cause injury on your fingers Selecting the Auto Cleaning Function Auto cleaning function offers inside air conditioner dry to prevent mold growth This feature allows you to use the air conditioner more clean and fresh air 1 Press the button gt When the air conditioner is turned off The gg indicator on
8. Contents PREPARATION m Safety Precautions m Name of Each Part m Remote Control Buttons and Display m Inserting the Remote Control Batteries m Getting Started OPERATION m Selecting Auto Mode m Selecting Cool Mode m Selecting Heat Mode m Selecting Dry Mode m Selecting Fan Mode m Selecting the Turbo Function m Selecting the Energy Saving Function m Selecting good sleep Mode m Adjusting the Airflow Direction m Selecting Auto Cleaning Function m Setting the On Timer m Setting the Off Timer m Selecting Silence Function IN m Operating Your Air Conditioner Without the Remote Control 24 m Selecting mpizone Mode uaeeeessesssssssssssssssssssssssesesssensessseenesssenesseeesnsssensssseeestt 25 RECOMMENDATIONS FOR USE m Cleaning the Air Filter on Your Air Conditioner sssssesssssseesesseeseesssseeeeees 26 m Cleaning Deodorizing and Bio filter Option sssssssseessssseeesseeeeesesseeeeees 26 m Temperature and Humidity Ranges m Operating Recommendations m Solving Common Problems csessssssesssesssseeessesseseeessnsssseceesasscseceesesnseeeetseesseeeeee Register your product at www samsung com global register Safety Precautions The following safety precautions are provided to protect the users safety and prevent property damage Make sure to read the followings and use the air conditioner properly D Keep this user s manual together with the i
9. Off Clean Mode Ca lo Set Temp Auto L N i m Ii good on Set Cancel Sleep a D Set Temp Auto good Set Cancel Sleep On Selecting Silence Function Silence function makes the noise much quieter during the operation of the indoor unit The silence function is set only in cool and heat mode 1 Press the On Off button ec Result The operation indicator on the indoor unit lights up WI ak The air conditioner starts up in the mode you selected last auto e The indoor unit beeps Digital On On Oo 2 Press the button 5 5 D By Pressing the 9 button again the silence function is canceled SA Operating Your Air Conditioner Without the Remote Control You can operate your air conditioner directly without the remote control 1 To turn the air conditioner on press the ON OFF switch on the right side of the indoor unit Result The Operation indicator on the indoor unit lights up The indoor unit beeps The air conditioner starts up in the appropriate mode for the room temperature The air conditioner changes the Cool or Heat mode automatically depending on the current temperature during operation Room Temperature Operating Mode Lower than 24 C Heating Higher than 24 C Cooling 2 To turn the air conditioner off press the On Off button again Even if you turned the air conditioner on with the On Off butt
10. Tocontrol the airflow direction refer to page 20 Selecting Dry Mode Select Dry mode if you want to dehumidify your room You can adjust the temperature in this mode 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps dt 2 Press the button on the remote control until Dry is displayed Result The indoor unit beeps each time you press the re button The air conditioner runs in the Dry mode You can change modes at any time 3 Press the OLO button to adjust the temperature until the required temperature is displayed You can set the temperature between 18 C and 30 C Result Each time you press the button The temperature adjusts by 1 C The indoor unit beeps The air conditioner starts dehumidifying and the fan speed adjusts automatically Fan Speed Set Temp Ju Auto L Ic Ww Mode Speea Set Temp Auto Gq tp 4 To control the airflow direction refer to page 20 ENGLISH Selecting Fan Mode al ao Mode Fan Speed Select Fan mode if you want to ventilate your room It helps to refresh the air in your room You can adjust the fan speed in this mode Mode Fan Spe a 1 Press the On Off button Result The operation indicator on the indoor unit lights u
11. after 3 minutes for the reason of protection Cooling operation The indoor unit may not get the selected fan speed such as Medium and Low under cooling operation at very low outdoor temperatures for the protection of the indoor unit from ice or frost During Low fan speed operation cooling performance will be reduced If the room does not be cooled down when using Low fan speed operation please adjust the indoor unit s fan speed Silence Mode When you operate Silence Mode in cooling and heating fan speed will decrease to make noise quieter As a result the performance of the unit may be reduced Solving Common Problems Before contacting the after sales service perform the following simple checks They may save you the time and expense of an unnecessary call ENGLISH Problem Explanation Solution The air conditioner does not Check if power is on and operate the air conditioner again operate at all Check if the circuit breaker is switched off Check if Off Timer is set The temperature is not adjusted Check if you selected the Fan mode The air conditioner does not operate Check if the air conditioner is cooling only model in the HEAT mode Check if the remote control is for cooling only model The cool warm air does not come Check if set temperature higher lower than current temperature out from the air conditioner Check if you selected the Fan mode Select the Cool
12. d in 8 hours if the operation time is not set ace ee You can set the Off timer by pressing the rey buttons to turn off the good sleep mode automatically at the appointed time within a range of 30 minutes to 12 hours Timer On Up good Set Cancel Sleep Each time the D buttons are pressed the time is e increased by 30 minutes or 1 hour good sleep mode will be stopped at the appointed off time Set Cancel Set Temp 5 Press the CO button Result The remaining time is displayed Auto Ce ood PES on Nowe In the case of selecting good sleep mode or adjusting the extra time for good sleep mode you should press the 5 button within 10 seconds If you do not press the lt 5 Baron within 10 seconds good sleep mode will be canceled automatically r ma 1 Z CS Timer on Up Set Can l 6 Press the QIO button to adjust the temperature until the desired temperature is displayed You can set the temperature between 16 C and 30 C Result Each time you press the QIQ button The temperature adjusts by 1 C The indoor unit beeps a Temperature changes in good sleep mode To prevent excessive cooling heating during sleep the good sleep mode automatically modifies the temperature setting in accordance with the time setting Temperature and air current change according to the three stages Falling asleep Sound sleep and Waking up from g
13. d the water from during operation reaching to person petora getting into the plant directly for a long time air conditioner gt Do not use the air conditioner gt Do not step on the air Do not drink the water from for a long time in a closed room conditioner or put heavy the air conditioner or in a place where there sa object on it E baby or an old person CAUTION DURING OPERATION gt Do not touch the pipes Do not use the air conditioner gt Do not give excessive shock connected to the air to maintain the machine food to the air conditioner conditioner pet plant or cosmetics OTHERS gt Be sure that the air filter notto gt The appliance is not intended gt The maximum input power amp be exposed to direct sunlight for use by young children or current is measured infirm persons without according to the IEC standard supervision Young children and the input power amp current should be supervised to ismeasured according to the ensure that they do not play ISO standard with the appliance gt Turn off the air conditioner and if the fan stops to operate clean the air conditioner i gt Do not clean the air The surface of the heat conditioner by spraying water exchanger is sharp so be directly or with benzene careful of it when cleaning thinner or alcohol gt Dispose of the packaging gt All of the
14. e if you want to cool your room You can adjust the temperature and the fan speed when cooling ENGLISH 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps dt 2 Press the Oo button on the remote control until Cool is displayed Result The indoor unit beeps each time you press the button The air conditioner runs in Cool mode pn You can change modes at any time cH 3 Press the OLO button to adjust the temperature until the required temperature is displayed You can set the temperature between 16 C and 30 C Result Each time you press the OIO button The temperature adjusts by 1 C 33 The indoor unit beeps auto LIS If the room temperature is higher than the selected temperature the air conditioner starts cooling if the room temperature reaches the set temperature the air conditioner stops cooling but the fan continues to operate 4 Press the eS button to select the fan speed until the required setting is displayed o et Temp IJ Auto Low Medium gt High E Sac Result Each time you press the eS button the indoor unit beeps Fan Speed 5 To control the airflow direction refer to page 20 Selecting Heat Mode You can select Heat mode if you want to heat your room You can adjust the temperature and the fan s
15. efully before using You have already seen the basic description of the unit on pages from 8 to 10 Starting with the next page you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use three different symbols HOLD DOWN Selecting Auto Mode You can select Auto mode if you want to cool or heat your room automatically You can adjust the temperature in this mode 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps d 2 Press the button on the remote control until Auto is displayed Result The indoor unit beeps each time you press the button The air conditioner runs in Auto mode Auto mode cools or heats the room depending on the set temperature The air conditioner changes from Cool or Heat mode SetTemp Auto automatically depending on the current temperature Ju Calc You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 16 C and 30 C Result Each time you press the OIO button The temperature adjusts by 1 C Im The indoor unit beeps Auto L L c p Set Temp Auto The fan speed adjusts automatically Selecting Cool Mode You can select Cool mod
16. epair move modify or reinstall the unit on your own Make sure that these installations are carried out by qualified personnel to avoid electric shock or fire gt Do not place any obstacles in front of the unit Make sure that the unit is correctly ventilated at all times Do not place clothing or other materials over it gt Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury Keep children away from the unit gt Never spill any kind of liquid into the unit Should this happen unplug or main switch off the unit and contact an authorized service center gt When using a wireless remote control the distance should not be more than 7 meters from the air conditioner If applicable gt If the wireless remote control is not used for along time remove the batteries If applicable gt The manufacturer declines any liability for damage resulting from modifications or errors in the electrical or hydraulic connections gt Do not connect the electric heater to the air conditioner or repair it with your discretion gt Failure to observe the installation instruction or use of the unit under conditions other than those indicated in the table Operating limit of the unit installation manual will immediately invalidate the unit warranty gt Do not place any materials so that children cannot step on it
17. equired setting is displayed Auto gt Low gt Medium gt High Fan Speed Result Each time you press the 5 button the indoor unit beeps 5 To control the airflow direction refer to page 20 ENGLISH Os O Fan Cc Set Temp Cool at C E Saver Auto CEN c E loft gt N E R nc Cc B W 1 E Saver Autol ti CE s e ee Set Temp Cool 20 auto L Le Mode Fan Speed as Selecting good sleep Mode good sleep mode helps users to fall asleep well after going to bed whether being too hot to sleep or being awakened by coldness The good sleep mode can be selected only when the air conditioner is switched on or off in cool heat mode 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps Caan O Fan ES 2 Press the button to select cool or heat mode Result The indoor unit beeps each time you press the button The air conditioner runs in cool or heat mode Set Temp jood 3 Pressthe E button Result The timer indicator is displayed The Off timer is blinking on the remote control 4 Tosetthegood sleep Off timer press the ory buttons once or more times until the required Off time is displayed atoll i Result The good sleep mode will be automatically stoppe
18. n Off Clean Mode Bjo Set Temp Auto 3 Press the 5 button to complete the setting 4 Press the 9 button until the desired mode is displayed at the top of the remote control to select the mode in advance Set Temp Auto Result The air conditioner operates in the selected mode when it is rH turned on The most recently used function is set between On and Off Timer Ibe to turn on off the air conditioner and good sleep mode On Timer of mpizone mode cannot be set out separately To Cancel the On Timer Set Cancel 1 Press the gt button to cancel the On Timer If you press the button both the On Timer and the Off Timer are canceled good On et Cancel Slee Setting the Off Timer You can set the Off Timer to turn off the air conditioner automatically at the appointed time within a range of 30 minutes to 24 hours 1 Press the C button 2 Press the cay or buttons until the desired time is displayed to set the Off Timer You can set the time between 0 5 hour and 24 hours Set Cancel 3 Press the C5 button to complete the setting Result The remaining time is displayed The timer indicator stops blinking The air conditioner turns off automatically at the appointed time and the Off Timer setting disappears If you would like to turn the air conditioner on after 2 hours and to operate it for 2 hours during non operation 1 Press the g
19. nstallation manual in a handy place so that you can find it whenever you need to see it after reading this manual thoroughly WARNING This indicates the possibility of serious injury or death Is CAUTION This indicates the possibility of serious injury or damage to environments when operated incorrectly WHEN INSTALLING gt Do not install the unit in a gt Do not connect the ground place where it isexposedto unit where there s the risk of to a gas pipe water pipe inflammable gas leakage dropping such as on high lightning rod or telephone outer wall or outside ofthe earth terrace gt Theinstallation must be carried out by a licensed installer or qualified personnel when installing the unit for the first time or reinstalling it 7 Contact the service center if the air conditioner is under water REGARDING POWER SOURCE A CH z gt Do not pull the electric wire gt Install the switch and circuit gt Use the rated current fuse or touch the power plug with breaker only for the wet hands air conditioner F gt Do not bend the electric wire gt Use the power source with gt If the power plug is by force or weigh down the separate wiring only for air damaged replace it by the air conditioner not tobe out conditioner manufacturer or qualified of order personnel to avoid the risk ENGLISH T WARNING DURING OPERATION gt Do not attempt to r
20. on you can control it with the remote control Selecting mpizone Mode The mpizone mode creates strong purified zone by decomposing harmful particles in the behavior of active hydrogen H and oxygen ion O The mpizone mode can be selected whether the air conditioner is turned on or not ENGLISH 1 Press the i button The air conditioner starts up in mpizone Auto mode automatically Es The mpizone mode also runs when the air conditioner is turned on By pressing the a button again the mpizone mode is canceled 2 Press the age to select the mpizone operation types Whenever press the Sa button Auto Silence and Rapid will appear repeatedly Auto Controls the fan speed automatically Silence Purifies the indoor air with silence Rapid Purifies the indoor air quickly mpizone Down On Off CleanMod fmpizone mode is turned on when the air conditioner runs You cannot select the mpizone operation types by pressing the Sni button The mpizone mode runs only in Auto The mpizone mode will also stop by pressing the Power button of the panel mpi Micro Plasma lon Cleaning Air Filter on Your Air Conditioner For the best use of your air conditioner you must clean it every 2 weeks regularly to remove the dust that accumulates on the air filter CAUTION Before cleaning your air conditioner ensure that you have switched off the breaker used for the unit
21. ood sleep mode and then the air conditioner will automatically turn off when the set time has elapsed Three stage good sleep prevents you from having difficulty sleeping on extremely hot cold nights Falling asleep Eases you into sleep by dropping the temperature Sound sleep Relaxes your body and raises your temperature slightly Waking up from good sleep mode Allows you to wake up to comfortable crisp air making you feel refreshed and energized Set the Off timer in good sleep mode for more than 5 hours Sleep may be disturbed if the good sleep mode is set for too short or too long a time because the temperature changes are set to an 8 hour cycle If the good sleep mode is set for less than 4 hours the operation will stop at the set time If the good sleep mode is set for over 5 hours the last hour will run in Waking Up stage before shutting off Recommended set temperature is between 25 C 27 C for cooling and 21 C 23 C for heating Cool mode When the 8 hour cycle completes this section repeats 1 2 3 4 5 6 7 8 Time hr Heat mode When the 8 hour cycle completes this section repeats 1 2 3 4 5 6 7 8 Time hr To deactivate good sleep mode 1 Press the Set Cancel button on the remote control good sleep mode shuts off and the good sleep indicator will disappear ENGLISH Adjusting the Airflow Direction Adjust the airflow direction
22. p The air conditioner starts up in the mode you selected last The indoor unit beeps 2 Press the ry button on the remote control until Fan is displayed Result The indoor unit beeps each time you press the button The air conditioner runs in Fan mode The temperature is set automatically You can change modes at any time Fan Speed 3 Press the Cc button to adjust the temperature until the required setting is displayed Low Medium gt High Fan Speed Result Each time you press the 5 button the indoor unit beeps ed 4 To control the airflow direction refer to page 20 Selecting the Turbo Function Ff A so Mode Fan Speed O You can select the Turbo Function if you want to cool or heat your room as quickly as possible The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected Di 2 gitalZowort ae ewe Oo 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps TURBO 2 Press the 5 button Result The temperature and fan settings are adjusted automatically The air conditioner cools or heats the room as quickly as possible After 30 minutes the air conditioner is
23. peed when heating 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps 2 Press the Oo button on the remote control until Heat is displayed Result The indoor unit beeps each time you press the button Set Temp The air conditioner runs in Heat mode Heat LI L Ic You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 16 C and 30 C Set Temp Result Each time you press the QIO button ym p The temperature adjusts by 1 C G He The indoor unit beeps If the room temperature reaches the set temperature selected temperature 5 C the air conditioner stops heating but the fan is still operating The air conditioner starts heating provided that the room temperature is lower than the desired temperature selected temperature 3 C Auto Fan Speed 4 Press the C button to select the fan speed until the required setting is displayed Set Temp Heat 70 Auto gt Low gt Medium High Auto C Result Each time you press the CS button the indoor unit beeps For the first 3 5 minutes the fan may not operate to prevent in cool air from flowing out of the indoor unit Fan speed This helps to warm the air in your room sufficiently 5
24. reset automatically to the previous setting You can select the Turbo function in Auto Cool and Heat mode If you select this function in Dry or Fan mode the mode changes to Auto mode 3 Press the 5 button again to stop the Turbo Function before the end of the 30 minute period Result The air conditioner is reset automatically to the previous setting 4 To control the airflow direction refer to page 20 Selecting the Energy Saving Function You can select the Energy Saving Function to save energy when cooling The temperature range decreases in order to perform this function 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps 2 Press the amp button Result The indoor unit beeps The air conditioner runs in the Energy saving function The outer airflow blade moves up and down The airflow direction indicator is displayed automatically To stop the Energy saving function press the amp again Note You can select the Energy saving function only in Cool mode 3 Press the 01 button to adjust the temperature until the required temperature is displayed You can set the temperature between 26 C and 30 C Note If you want to adjust temperature under 26 C cancel the Energy saving function before adjusting the temperature 4 Press the ES to select the fan speed until the r
25. rt Water may form due to the difference of the temperature SYMPTOMS CHECK ERROR MODE DISPLAYED MANAGEMENT Some signal is displayed on the window LED like MI ERE fil This product has something The abnormal signal is cr EN All blink ZH wrong please call the nearest displayed RIES BEES contact center ELECTRONICS Contact SAMSUNG WORLD WIDE If you have any comments or questions regarding a Samsung product contact the SAMSUNG customer care center Samsung Electronics Australia 7 Parkview Drive Homebush Bay NSW 2127 www samsung com au 1300 362 603 Samsung Electronics Co Ltd All Rights Reserved USER S MANUAL AQVO9VB Series AQV12VB Series AQV18VB Series AQV24VB Series Split type Air Conditioner Cooling and Heating os E DB98 29568A 1
26. t button Down 2 Press the cy or C75 buttons until 2 0 Hr is displayed Set Cancel 3 Press the _ button 4 Press the button Down 5 Press the cy or Cy buttons until 4 0 Hr is displayed Set Cancel 6 Press the gt button If you would like to turn on the air conditioner and then to turn off it automatically at the appointed time by using On Off Timer during operation you should set the On Timer longer than the Off Timer Make sure that the air conditioner will not continue to run after On Timer setting is confirmed You can check or change the mode and or the temperature by pressing the button or the button after setting the Off Timer The most recently used function is set between On and Off Timer to turn on off the air conditioner and good sleep mode Off Timer of mpizone mode cannot be set out separately If you would like to turn off the air conditioner and then to turn on it again automatically at the appointed time by using On Off Timer during non operation you should set the Off Timer longer than the On Timer To Cancel the Off Timer Set Cancel 1 Press the gt button to cancel the Off Timer Set Cancel If you press the _ button both the On Timer and the Off Timer are canceled ENGLISH Set Temp Auto Ju Auto L Ic gt ars BU Hr mpizone On Off Clean Mode Gi Set Temp Auto LI Auto L j C Mpizone off Down On
27. that you read the following Topic Recommendation Heating capacity The heat pump inside the air conditioner absorbs heat from outside air and brings itindoors If the temperature of the outside air drops the air conditioner heats less If the room is not warm enough use an additional heating appliance Warm air circulation The air conditioner circulates warm air to heat your room It will take some time to warm the air in your room entirely after the air conditioner turns on Therefore turn the air conditioner on in advance Frost High indoor and outdoor temperatures When you select the Heat mode frost may form in the outdoor unit due to low temperature and high humidity If this happens The heating operation is stopped The air conditioner defrosts automatically for about 7 minutes After about 7 minutes the air conditioner starts operating again normally If both the indoor and outdoor temperatures are high when you select the Heat mode the fan and the compressor of the outdoor unit may stop periodically This is normal wait until the air conditioner turns on again Power failure If a power failure occurs when the air conditioner is operating the air conditioner will turn off When the power returns the air conditioner will start up again automatically Protection mechanism When the air conditioner is started immediately after being plugged in or stopped the normal operation starts up
28. ton Digital On Off button Turbo button Fan speed adjustment button Auto Cleaning button Energy saving button Silence button Timer a on f Up Set Cancel R l ood sleep b On Timer button WE ADI GR g P button i i Timer Set Cancel button off Down On Off Clean Mode l Off Timer button lt _ iC CG GE mpizore mode adjustment button Time adjustment button mpizone On Off button Digital On Off button If you want to turn on or off the Display of the indoor unit during SA M S UNG operation press the s sf button on the remote control Inserting the Remote Control Batteries You must insert or replace the remote control batteries when You purchase the air conditioner The remote control does not work correctly Use two AAA LRO3 1 5V batteries Do not use old and new batteries or different kinds of batteries together Insert two batteries correctly as indicated by the and symbols 1 Remove the battery cover in the rear of the remote control by pushing it with your thumb 2 Insert two batteries respecting the polarities as indicated by the and symbols 3 Close the cover by sliding it back in place ENGLISH Getting Started The User s Manual provides you with valuable information about your air conditioner In order to take full advantage of the air conditioner s features please read this manual car