Premier 888/8168 Installation Manual - EZ

image

Contents

1. 00 Alarm 19 Exit Mode 38 DK First Knock 01 Guard Alarm 20 Entry Exit Mode 39 Zone On Test 02 Guard Access Alarm 21 Armed 40 Test Fail 03 Entry Alarm 22 Full Arm 41 Internal Alarm 04 Confirmed Alarm 23 Part Armed 42 05 24Hr Audible 24 Force Armable 43 06 Forced Entry 25 Force Armed 44 07 24Hr Gas 26 Arm Fail 45 08 PA Audible 27 Bell SAB 46 09 PA Silent 28 Strobe 47 10 Duress 29 Detector Latch 48 11 Fire Alarm 30 Detector Reset 49 12 Medical Alarm 31 Walk Test Active 50 13 Auxiliary Alarm 32 Zones Omitted 51 14 Tamper Alarm 33 24Hr Zones Omit 52 15 Alarm Abort 34 Reset Required 53 16 Ready 35 Door Strike 54 17 Entry Mode 36 Chime Mimic 18 2 Entry Mode 37 Chime Enabled Time Arming Part Armed 1 Part Armed 2 Part Armed 3 Zones Locked Out Armed Alarm Full Entry Mode Intruder Alarm Sounder Mimic Detector Fault Detector Masked Fault Present LED Control Attributes Use to enter an output type or use to search to accept 01 24 Zone 1 to 24 Mimic 25 48 Zone 1 to 24 Alarm Attribute Types Attributes Press to edit D to select attributes to accept dD User Test U Latch Until L Inverted I Use Pulse Timer 1 1 INS249 Premier 24 Quick Reference amp Factory Defaults Quick Reference Guide UDL Digi Options Reset Digi Press to reset digimodem Start Test Call Press to send test call to the ARC G D to initiate a ca
2. 8 User Codes Com Channels As Panel Outputs Not Used Keypads 1 4 Outputs LED Control Expanders 1 2 Outputs LED Control Armed Detector Test Not Used PGM Outputs Zones Locked Out Not Used Not Used Control Timer 4 Not Used Setup Users User 00 Engineer User 01 Master User 02 16 1234 5678 Not Defined Global option 24 alters the Programming of the control panel as defined below aS These options are enabled disabled when Config Option 24 is programmed as Grade 2 3 All users except the engineer are defaulted to lock out during entry INS249 Quick Reference Guide Premier 24 Quick Reference amp Factory Defaults 2 Quick Reference Guide Log Off Engineer 810 Press to log out of the Engineer Programming menu Zone Setup Zone Types Use to enter zone number to edit or to select a zone type to accept Not Used Entry Exit 1 Entry Exit 2 Guard Guard Access 24Hr Audible Trouble PA Audible PA Silent Fire 24Hr Gas Auxiliary Tamper Exit Terminator Key Switch 00000000 Zone Attributes 1 Press to edit G amp D to select an attribute to accept O Omittable 3 Part 3 Omit F Force Omit 1 Chime 1 1 Part 1 Omit 2 Chime 2 2 Part 2 Omit G Guard Entry 2 0000 0000 Zone Attributes 2 not applicable to keyswitch zone tvnes Press to edit
3. Press to edit to select an option to change the option to accept a gt E Digi is Enabled B Blind Dialling P Pulse Dialling GD R Reserved 3 Pulse after 3 A Dial All UDL Options Call Back Number 1 Press to edit to enter the number to accept pressing repeatedly Inserts a 3 second pause W 10 second pause R recall signal Call Back Press to edit call back number 2 to enter the number to accept UDL Password Press to edit to enter number to accept UDL options Press to edit to select an option to change option to accept a A DL Attended L Armed DL M Manual Call back Gud A Only Full D Call Defeat On K Online Number of Rings Press to edit to enter number of rings to accept Dialling Attempts Press to edit to enter number of dialling attempts to accept Radio SMS Option Use to select option to edit to enter numbers to accept 1 Pad ARC1 Pri 4 Pad ARC2 Pri 7 2 Pad ARC1 Sec 5 Pad ARC2 Sec 8 3 Pad ARC1 Prefix 6 Pad ARC2 Prefix SMS Centre SMS Centre INS249 Quick Reference Guide Premier 24 Quick Reference amp Factory Defaults UDL Digi Options continued Com Port Setup Options depend on com port Use to select a com port to edit to select an option to accept Nothing Fitted Com2400 Radio Pad Radio Plus Com300 ComISDN GSM Module Setup Users User Code
4. Use to enter a code to accept User Types Use to select a user type to accept Engineer Standard aD Master Shunt Manager G gt Duress Reset Only Door Strike User Options 1 only available to Custom users Press to edit to select an option to change option to accept aD Arming G gt Lock CODE by PGM3 Disarming Lock USER by PGM4 Omitting Auto YES Lock TAG by PGM2 Send Open Close User Text Press to edit to select characters press the required key the appropriate number of times to accept WXYZ9 0_ D Move Cursor JKL5 MNO6 PQRS7 TUV8 211 ABC2 DEF3 GHI4 Engineer Utils View System Log Use to move up and down through log down moves back in time up moves forward again to show other information G gt to find specific events Do Bell Test Use gt to select an option use QD or to activate outputs 1 Test Bell 5 2 Test Strobe 6 3 Test Speaker 7 4 User Outputs LCD Display Test Panel Test Comms Do Walk Test Press to display zones that have been tested still need testing to make zones Chime every time they are activated View Zone Status Use to enter zone number or use to search to walk test selected zone to omit zone temporarily View Version No Press to view hardware information Confirm Devices Use to select network to confirm Devices Check RKP Status Use
5. 1 Auto Part Arm Part Arm Silent Remote Arm Time Arm CT1 Alarm Eng Reset Confirmation Reset Tamper Eng Reset Anti code Reset Disabled Disabled Enabled Disabled Disabled Enabled Disabled Enabled Options 2 Arm With No ATS Arm With AC Fail Part Arm Coms Unarm Fire Coms Unarm Tamper Coms Log Part Omits Confirm In Entry Conf After Entry Enabled Enabled Disabled Disabled Disabled Disabled Disabled Enabled Options 3 Faults Eng Reset No ATS Eng Reset AC Fail Eng Reset 4 Anti Masking When Armed 5 Remote FOB After Entry 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 Disabled Disabled Disabled 00 Bell on Arm Fail 01 Bell is an SCB 02 Manual BST GMT 03 Leave Omits 04 Enforce Com Delay 05 NVM is Locked 06 Engineer Only 07 Omit Tampers NO 08 40 Column Printer 09 View Act Fault 10 View Zone Faults 11 No Code Tamp 12 Code Tamp Alarms 13 Zone Short Active 14 R R Silence RST 15 Test Call CT3 16 Batt Test Disarm 17 Bell 2nd Alarm 18 SNDR 2nd Alarm 19 Abort User Reset 20 8XE Tampers 1 8 21 1st Zone Confirm 22 Access Confirm 23 EN50131 Disabled 24 Panel Grade 3 25 Disable RF PA s 26 Armed Mask Alarm 27 RF PA Silent Periodic Test Calls No Bell SAB Auto Remove Override Unlocked User Engineer YES 80 Hide Hide Enable Locks Tamper Reset
6. Dial Any Speaker Tones All Tones 4 Keypad Setup Enabled Zone Mapping All Keypad zones Not Mapped Options PA Enabled Fire Enable Medical Enabled Tamper Disabled PA Audible PA Delayed Quick Arm Keys Info LED gt Output AN O O1 amp WN Disabled Disabled Disabled Enabled Silent Instant Off Armed UDL Options Call Back Number 1 Call Back Number 2 UDL Password DL Attended Auto Call Back Call Defeat Off DL Arm Limited Download When Armed Disable On Line Keypad Rings Required UDL Dial Attempts Not Defined Not Defined Not Defined Unattended Manual On At Anytime Fully Armed Enabled 005 003 Volume All Keypads 5 Sounder Options All Tones 5 Expander Setup Enabled Auxiliary Input All Expanders Volume All Expanders Sounder Options All Tones Not Used 5 Enabled Radio SMS Setup Pad ARC 1 Pri No Pad ARC 1 Sec No Pad ARC 1 Prefix Pad ARC 2 Pri No Pad ARC 2 Sec No Pad ARC 2 Prefix SMS No1 SMS No2 Not Defined Not Defined Not Defined Not Defined Not Defined Not Defined 07860980480 07785499993 6 Output Setup Panel Outputs 1 Fire PA Alarm Armed Zones Locked Out Fault Present Confirmed Alarm Abort Tamper AC Mains Fail ATS Remote Test Not Used Not Used LED Control Armed Detector Test Com Port Setup Onboard Digi Com 1 Com 2 Com300 No Module Fitted No Module Fitted
7. Gi to select keypad to test output to test sounder 0000 Check Exp Status Use D to select expander to select network to display zones voltage outputs to test zones to test sounder G gt to test outputs Set System Time Use to enter time 24 hour format HD CHD GD CMD to accept Set System Date Use to enter date DOC GD GD QD Ce to accept C0 Change Eng Code Use to enter a code to accept Alter Part Arms Press to enter zone number or use to search Crd or to select Part Arms 1 2 or 3 Part Arm 1 Part Arm 2 Part Arm 3 10 INS249 Premier 24 Quick Reference amp Factory Defaults Notes INS249 11 Texecom www texe com Texecom Limited Bradwood Court St Crispin Way Haslingden Lancashire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at 3 36 pence per minute from a BT landline Calls from other networks may vary International Customers Tel 44 1278 411707 Email techsupport texe com Texecom Limited 2007 INS249 2
8. gt to select an attribute to accept D Double Knock S Shunt Group T Soak Test F Activity Reset R I Inverted Q Quick Resp Shock Key Attributes 2 only applicable for keyswitch zone types 10 00 Co it I Instant Arming s Shunt Key F Full Disable Q Quick Resp D Disarm Only L Latching o 2 Q Q 5 9 D Ces S Silent Arming 2 O O T I Inverted 8600560000 0000 Zone Text Press to edit to select characters press the required key the appropriate number of times to accept 11 GD ABC2 DEF3 PQRS7 GHI4 TUV8 JKL5 MNO6 WXYZ9 o D Mowe Cursor 0000 Wiring Type Press to alter wiring type to accept Normally Closed 1K 1K 3K Normally Open 4K7 6K8 12K Double EOL 2K2 4K7 6K8 iD 4K7 4K7 Triple EOL 00000 INS249 Premier 24 Quick Reference amp Factory Defaults Quick Reference Guide Arming Options Use or to select a timer to enter a value to accept Exit Delay 2 d Entry Delay Coms Delay QD Entry Delay 1 Bell Delay Part Bell Delay Entry Delay 2 G gt Bell Duration Arming Modes Use to select full arm or part arm 1 3 GD GD to select arming an mode to accept QD Entry Exit Timed Exit Gu Deferred Exit Term Instant Options Options 1 Options 2 Options 3 Bu N e T oO
9. Only Timed Timed 1st Alarm 1st Alarm Eng Zones 9 16 ond No Conf Enabled 2 Enable Fault Audible Dynamic Disabled System Options Disabled Advisory Volume Chime Volume No of Re Arms Anti code Resets Quick Count Modem Level 5 3 03 03 4 0 Monitor Hardware ATS Path Fault Power Failure Aux Fuse Blown Bell Tamper Aux Tamper Panel Lid Tamper Battery Faults Enabled Enabled Enabled Enabled Enabled Enabled Enabled INS249 Premier 24 Quick Reference amp Factory Defaults Factory Defaults Menu Option Default 3 Global Options Continu ed Menu Default Control Timers 1 4 Not Defined 7 UDL Digi Options System Text Reset Message Anti code Message Service Message Location Text Banner Message Part Armed Banner Printer Header Part Arm 1 Part Arm 2 Part Arm 3 Call Engineer to Reset System Call ARC Centre to Reset System Call Alarm Co For Service No Location Text Has Been Setup Not Defined PART ARMED Not Defined Evening Arm Bedtime Arm 1 Bedtime Arm 2 Reset Digi N A N A Test Com N A N A Set Call Waiting Number Not Defined Program Digi ARC 1 ARC 2 Not Defined Not Defined Digi Options Digi is Enabled Pulse Dialling Pulse After 3 Blind Dialling Reserved Dial All Numbers Disabled Tone Always Tone Wait Dial Tone N A
10. Quick Reference Guide amp System Records ssue CE Texecom www texe com Factory Defaults Premier 24 Quick Reference amp Factory Defaults 1 Factory Defaults Option User Codes Default Option 3 Global Options Default Setup Users User 00 Engineer User 01 Master Users 02 16 1 Zone Setup 1234 System Timers 5678 Not Defined Zones Types 1 2 3 8 Zones 9 24 Entry Exit 1 Guard Access Guard Not Used Zone Text All Zones Not Defined Zone Chime All Zones Silent Zone Wiring 1 24 2 Arming Options Double Pole EOL Timers Exit Delay Entry Delay 1 Entry Delay 2 2 Entry Dly Bell Delay Bell Duration Coms Delay Part Bell Dly 030 Seconds 045 Seconds 01 Exit Settle Time 02 Double Knock Dly 03 Activity Delay 04 Abort Delay 05 Courtesy Time 06 Pulse Period 1 07 ATS Fault Delay 08 AC Off Delay 09 Batt Test Period 10 Batt Test Time 11 Soak Test Time 12 Service Interval 13 Test Call Every 14 Zone Response 15 Confirmation Dly 008 Seconds 007 Seconds 024 Hours 180 Seconds 030 Seconds 010 Seconds 000 Minutes 005 Minutes 024 Hours 010 Seconds 014 Days 000 Weeks 024 Hours 008 x 8mSec 060 Minutes 045 Seconds 000 Seconds 000 Minutes 015 Minutes 000 Seconds 000 Seconds System Config Arming Modes Full Arm Part Arm 1 Part Arm 2 Part Arm 3 Entry Exit Instant Instant Instant Options
11. S 22 Access No Conf Confirm 08 80 40 Column Printer 23 EN50131 Disabled Enabled 09 Activity Fault View Hide 24 Panel Grade 2 Grade 3 10 Hide View Exit Errors 25 RF PA Disabled Enabled 11 No Enable Code Tampers 26 Armed Mask Fault Alarm 12 Code Tamp Alarms Locks 27 RF PA Audible Silent 13 Zone Short Active Tamper 28 Dynamic Periodic Tests 14 R R Reset Only Silence RST System Options Use to select an Option to enter a value to accept Advisory Volume Anti code Resets QD Chime Volume Quick Count Number Of Re Arms Gu Modem Level INS249 5 Quick Reference Guide Premier 24 Quick Reference amp Factory Defaults Global Options Monitor Hardware Press to edit to select an option to change the option to accept QD ATS Path Fault Gs Auxiliary Tamper Mains Power Off Panel Lid Tamper Auxiliary Fuse Blown Battery Fault Bell Tamper Control Timers Use to select an timer to enter the 1 On time to accept Use GD to select the 1 On time days of operation to accept Use to enter the 1 Off time to accept Use dD to select the 1 Off time days of operation to accept System Text Use to select a message to select characters press the required key the appropriate number of times to accept Speaker Tones Use to select a tone type to turn the tone on off to accept Keypad Setup Zone Mapping Press to edit to enter z
12. ao Oo Ls 2 Ge V 2 Q Q o E gt Ces em D o a D Q 2 3 ok Auto Part Arm Part Arm Silent Remote Arm Disarm Time Arming CT1 Alarm Eng Reset Tamper Eng Reset Anti code Reset 00 Confirmation Reset Arm With L Fault Arm With AC Fail Part Arm Coms Unarm Fire Coms Confirm in Entry Conf After Entry 00 Unarm Tamper Coms Log Part Omits 3 Faults Eng Reset FOB After Entry No ATS Eng Reset AC Fail Eng Reset Mask When Armed 0010 000 00 00000000 Global Options System Timers Use to select a timer to enter a value to accept Exit Settle Time Gs Pulse Period 1 Soak Test Time GD Double Knock Dly Line Fault Delay gt Service Interval Activity Delay AC Off Delay D Test Call Every Abort Delay Batt Test Period gt Quick Response Courtesy Time Batt Test Time Confirmation Dly a System Config Use to select an option to change the option to accept 00 No Bell Bell on Arm Fail 15 Test Call Timed Timed 01 Bellis an SAB SCB 16 Batt Test Timed Disarm 02 Manual Auto BST GMT 17 Bell 15 Alarm 2 Alarm 03 Leave Remove Omits 18 SNDR 1 Alarm 2 Alarm 04 Away Override Enforce Delay 19 Abort Eng Reset User Reset 05 NVM is Unlocked Locked 20 8XE Zones 9 16 Tampers 1 8 06 Engineer Only User 21 2 Zone 1 Zone Confirm 07 Omit Tampers NO YE
13. ll to the remote UDL computer using Call Back numbers 1 2 or 3 Program Digi Use Gi to select ARC 1 2 to edit Protocol Press to edit to select protocol to accept Disabled Contact ID aD Fast Format SIA Level II SMS Telephone Number 1 Press to edit to enter the number to accept pressing repeatedly Inserts a 3 second pause W 10 second pause R recall signal Telephone Press to edit telephone number 2 to enter the number to accept Account Number Press to edit to enter number to accept Dialling Attempts Press to edit to enter number to accept Reporting Press to edit D to select channels to accept only for Fast Format Restoring Press to edit G D to select channels to accept only for Fast Format Open Close Press to edit G amp D to select channels to accept only for Fast Format Reporting Options Press to edit D to select option to accept only available for Contact ID SIA Level Il EasyCom Pager and SMS Messaging a Gud C Open Close O Omits amp Reinstates M Maintenance T Tamper C Test Calls R Restores P Priority Alarms A Normal Alarms Press to edit D to select option to accept only available for Contact ID SIA Level II EasyCom Pager amp SMS Messaging a gt D Disable Zone R Enable RadioPad G amp D F Use S Use SIA I G Enable GSM Digi Options
14. one number to accept Repeat for 2 zone Options Press to edit to select an option to change the option to accept P PA Enabled G gt A PA is Audible F Fire Enabled D PA is Delayed M Medical Enabled Q Quick Arm On T Tamper Enabled O Info LED gt Output Volume Press to edit to enter a value to accept Sounder Options Press to edit C to select an option to change the option to accept F Fire Tones Enabled A Alarm Tones Enabled F Fault Tones Enabled S Service Tones Enabled Expander Setup Gs E Entry Tones Enabled X Exit Tones Enabled C Chime Tones Enabled Auxiliary Input Press to edit _D to select an input type to accept Not Used a gt Auxiliary Tamper Bell Tamper Silence Sounders PSU Fault Gs Shunt Key Volume Press to edit to enter a value to accept Sounder Options Press to edit to select an option to change the option to accept F Fire Tones Enabled A Alarm Tones Enabled F Fault Tones Enabled S Service Tones Enabled a GD E Entry Tones Enabled X Exit Tones Enabled C Chime Tones Enabled INS249 Premier 24 Quick Reference amp Factory Defaults Quick Reference Guide System Outputs Panel Outputs Use G amp D 7 to select an output to edit G to enter an output group Com Channels to enter output type to accept Keypad Outputs Use to
15. select keypad expander to select network to select an output to edit gt to enter an output group to enter output type Expander Outputs to accept PGM Outputs Use to select output gt to select a switch to edit to enter an output group to enter output type to accept Output Group Outputs Types Not Used Press to accept System Use to enter an output type or use to search to accept 00 ATS Path Fault 15 Digi Failed 29 Com Port 2 Fault 01 Mains Power Off 16 Digi Successful 30 Code Accepted 02 Aux Fuse Fault 17 Digi Active 31 Prox TAG Accepted 03 Auxiliary Tamper 18 UDL Lockout 32 Radio Jamming 04 Bell Tamper 18 UDL Lockout 33 Detector Test 05 Panel Lid Tamper 19 UDL Call Active 34 ATS Remote Test 06 Engineer Working 20 UDL Enabled 35 No ATS Available 07 Confirm Devices 21 Custom Output 36 CIE Fault 08 Service Required 22 Activity Fault 37 PSU Fuse Blown 09 Shunt Active 23 No Battery 38 PSU Battery Fit 10 Battery Fault 24 Control Timer 1 39 iD Loop Shorted 11 Battery Test On 25 Control Timer 2 40 Radio Plus Tamper 12 Courtesy Light 26 Control Timer 3 41 GSM No Signal 13 PC Output 1 27 Control Timer 4 14 PC Output 2 28 Com Port 1 Fault INS249 7 Quick Reference Guide Premier 24 Quick Reference amp Factory Defaults Output Group Outputs Types Alarm Use to enter an output type or use to search to accept