Home

Installation Manual INTEGRATED ACCESS CONTROLLER

image

Contents

1. Installation Manual INTEGRATED ACCESS CONTROLLER PROXIMITY CARD READER KZC 300 U H BLACK KZC 300 U H WHITE asKKaDe VERSION 1 0 oa Holding sp z 0 0 Pu awska 431 02 801 Warszawa tel 22 546 05 46 faks 22 546 05 01 www aat pl Integrated Access Controller Installation manual 1 Introduction s KaDe KZC 300 U H BLACK KZC 300 U H WHITE Integrated access controller reader The KZC 300 U H is a single door multifunction standalone access controller or a Wiegand output reader It uses Atmel MCU assuring stable performance packed with small Infrared Remote Control the operation is very user friendly low power circuit makes it long service life The KZC 300 U H supports 1 000 users 998 common users 2 panic us ers all user data can be transferred from one to another Max 10pcs It sup ports multi access modes in either card access PIN access Use PIN on the In frared Remote Control Card PIN access or multi cards PINs access It has extra features including block enrollment interlocked Wiegand 26 37 bits inter face etc All rights reserved AAT Holding sp z o o 2 Integrated Access Controller Installation manual Detail features Waterproof conforms to IP66 One relay remote infrared programmer 1 000 users 998 common users 2 panic users Can add and use 4 6 digits PIN on Infrared Remote Control Can be set to read EM card HID card or both Wiegand 26 37 bits input amp outp
2. Reader in a single step Cards number must be consecutive Takes 2 minutes to program Card quantity number of cards to be en rolled Add PIN User 2 Add PIN Using Auto ID 1 PIN Allows KZC 300 to assign PIN to next availa The PINs can be added continuously ble User ID number PIN 4 6digits 2 Add PIN Select Specific ID 1 User ID PIN Allows manager to define a specific User ID The user ID is any number from 0 997 to associate the PIN to Add Panic Users Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Add Card 1 User ID Read Card Input 8 10 digits Card number OR 2 Add PIN 1 User ID PIN User ID is any number from 998 999 Change PIN Users Programming Step Keystroke Combination Note Below is done outside programming mode users can undertake this themselves 2 Change PIN By Card Read Card Old PIN New PIN There will auto allocate PIN 8888 to cards Repeat New PIN when adding 2 Change PIN By PIN User ID Old PIN New PIN Repeat New PIN All rights reserved AAT Holding sp z 8 Integrated Access Controller Installation manual Delete Users Programming Step Keystroke Combination 1 Enter Program Mode Master Code Delete Card User Common 2 Delete Card By Card 2 Read Card OR The cards can be deleted continuously 2 Delete Card By ID numbe
3. and the LED light turns into yellow release the exit button then read any two 125KHz EM card or HID card the LED will turn into red means reset to factory default successfully Of the two cards reading the 1 one is Master Add Card the 2 one is the Master Delete Card Remarks 1 If no Master Cards added must press the Exit Button for at least 10 seconds before release 2 Reset to factory default the user s information is still retained Access controller mode In this mode unit works as controller This is factory default mode command 7 2 It s possible to connect additional reader for two way control To change unit for Wiegand reader mode please use command 7 3 this mode is describe on next pages Reader Red 1d 12V Black GND Green DO White 01 Brown LED Yellow BZ Controller Attention Install a 1N4004 or equivalent diode is needed when use a common power supply or the reader might be damaged 1N4004 is included in the packing All rights reserved AAT Holding sp z o o 11 Integrated Access Controller Installation manual Set Wiegand Input Formats Please set the Wiegand input formats according to the Wiegand output format of the external Reader Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 6 input bits 8 26 37 factory default is 26bits pr C Programming Basic Programming is the same as Standalone Mode There are
4. is included in the packing Programming by Infrared Remote Control Programming will vary depending on access configuration Follow the instruc tions according to your access configuration Notes User ID number Assign a user ID to the access card in order to track it The common user ID number can be any number from 07997 the panic user ID is from 998 999 IMPORTANT User IDs do not have to be proceeded with any leading zeroes Recording of User ID is critical Modifications to the user require the User ID be available Proximity Card Any 125KHz industry standard 26 bit EM and HID Proximity card or Tag PIN Can be any 4 6 digits except 8888 which is reserved Press PIN on the In frared Remote Control All rights reserved AAT Holding sp z o o 7 Integrated Access Controller Installation manual Add Common Users Programming Step Keystroke Combination 1 Enter Program Mode Master Code Add Card User 2 Add Card Using Auto ID 1 Read Card Allows KZC 300 to assign Card to next avail The cards can be added continuously able User ID number OR 2 Add Card Select Specific ID 1 User ID Read Card Allows Master to define a specific User ID to User ID is any number from 0 997 associate the card to OR 2 Add Card by Card Number 1 Input 8 10 digits Card number OR 2 Add Card Block Enrolment 1 User ID Card quantity The Allows Master to add up to 998 cards to the first card number
5. 6 1 Access will be denied for 10 minutes OR 2 Strike Out ON Alarm 6 2 Set alarm time 5 0 30 factory default is 1 minute Enter Master code or valid user card PIN to silence Set Audible and Visual Response Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Control Sounds OR 2 Control LED OFF 74 ON 75 factory defaults are ON Set Card Reading Type Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Read EM amp HID card 93 factory default OR 2 Read EM card ONLY 94 OR 2 Read HID card ONLY 95 Master Cards Usage Using Master Card to add and delete card users Add a Card User 1 Read Master Add Card 2 Read User Card Repeat Step 2 for additional user cards 3 Read Master Add Card Delete a Card User 1 Read Master Delete Card 2 Read User Card Repeat Step 2 for additional user cards 3 Read Master Delete Card All rights reserved AAT Holding sp z o o 10 Integrated Access Controller Installation manual Users Operation amp Reset to Factory Default Open the door Read the valid user card Input the valid PIN on the Infra red Remote Control the door will open Remove Alarm Read valid user card Input the valid PIN on the Infrared Remote Control or Input Master Code To reset to factory default power off press the Exit Button hold it and pow er on there will be two beeps
6. Access Controller Installation manual Connection Diagram KZC 300 U H in Wiegand reader mode Third party controller Notes When set into Wiegand Reader mode nearly all settings in Controller Model will become invalid And Brown amp Yellow wires will be redefined as below Brown wire Green LED light control Yellow wire Buzzer control If you need to connect Brown Yellow wires When the input voltage for LED is low the LED will turn into Green and when the input voltage for Buzzer is low it will sound Set Wiegand Output Formats Please set the Wiegand output formats of Reader according to the Wiegand in put formats of the Controller Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Wiegand output bits 8 26 37 factory default is 26bits All rights reserved AAT Holding sp z o o 13 Integrated Access Controller Installation manual ADVANCE APPLICATION User Information Transfer The KZC 300 supports the User Information Transfer function and the enrolled user cards PINs can be transferred from one let s name it Master unit to an other let s name it accept unit Maximum 10pcs accepts units can be trans ferred once Connection Diagram Green DO White D1 Remarks e he Master units and Accept units must be KZC 300 e he Master Code of the Master Unit s and the Accept Units s must be set to the same e Program the transf
7. alid card or input PIN on Reader A door 1 will open then when and only door 1 closed read valid card or input PIN on Reader B door 2 will open All rights reserved AAT Holding sp z o o 15 AY _ AAT Holding sp z o o 4 mu PEAN Pu awska 431 St 02 801 Warsaw tel 4822 546 05 46 fax 4822 546 05 01 e mail aat warszawa aat pl www aat pl
8. er operation on Master Unit only e If the Accept Unit s are already with the users enrolled it will be covered af ter transfer e For full 1000 users enrolled the transfer takes 3 minutes Set Transferring on Master Unit Programming Step Keystroke Combination 1 Enter the programming mode Master Code Within 3 minutes Green LED shines after one beep the LED will turn into Red which means the users information has been transferred successfully _ All rights reserved AAT Holding sp z 0 0 14 Integrated Access Controller Installation manual Interlock The KZC 300 supports the Interlock function It is of two readers for two doors and mainly used for banks prisons and other places where a higher level secu rity is required DC Power Supply Connection Diagram I Magnate E becker a Fall Sale Look I KZC 300 U H KZC 300 U H Remarks The Door Contact must be installed and connected as the diagram Let s name the two readers A and B for two doors 1 and 2 Step 1 Enrol the users on Reader A then transfer the users information to Reader B by User Information Transfer function Step 2 Set both of the two readers A and B to Interlock function Programming Step Keystroke Combination 1 Enter Program Mode Master Code b aan OR 2 Interlocked ON 915 The interlock operation is finished When and only door 2 is closed the user can read the v
9. it Drill 2 holes A C on the wall for the screws and one hole for the cable Knock the supplied rubber bungs to the screw holes A C Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole B Attach the unit to the back cover ad Step2 Step 1 All rights reserved AAT Holding sp z o o Integrated Access Controller Installation manual Wiring diagram N __________ ACEO 12 24V Power Input Normally Closed Relay Output Install diode provided Request to Exit REX Input Pass Through Wiring Wiegand or Controller Green Wiegand Output Pass through Data 0 Wiegand Output Pass through Data 1 Advanced Input and Output Features Negative contact for Alarm Door Gate Contact Input Normally Closed Sound and Light Indication Operation seus CRD eee Exit from the programming Red light bright mode Basic Configure Please use the Infrared Remote Control to program the Reader The infrared receiver head is near LED so when program the reader it is suggested to direct the Remote Control to the LED Enter and Exit Program mode Programming Step Keystroke Combination Enter Program Mode Master Code Factory default is 123456 All rights reserved AAT Holding sp z 0 0 5 Integrated Access Controller Installation manual Set Master Code Programming S
10. r 2 User ID OR 2 Delete User By Card number 2 Input 8 10 digits Card number Delete PIN User Common 2 Delete PIN by PIN 2 Input PIN OR 2 Delete PIN By ID number 2 User ID Delete Panic User 2 Delete Panic Card User 2 User ID OR 2 Delete Panic PIN User 2 User ID Delete All Users Delete All User 2 Master Code Set Relay Configuration The relay configuration sets the behaviour of the output relay on activation Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Pulse Mode 3 1 99 factory default The relay time is 1 99 seconds 1 is 50mS OR Default is 5 seconds 2 Toggle Mode Sets the relay to ON OFF Toggle mode Set Access Mode Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Card access 40 OR 2 Card PIN access 415 OR 2 Card or PIN access 4 2 OR 2 Multi Cards or PINs access 4 3 2 9 All rights reserved O AAT Holding sp z o o Integrated Access Controller Installation manual Set Strike out Alarm The strike out alarm will engage after 10 failed card attempts Factory is OFF It can be set to deny access for 10 minutes after engaging or disengage only af ter entering a valid card PIN or Master code Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Strike Out OFF 6 0 factory default OR 2 Strike Out ON
11. some exceptions for your attention KZC 300 connected with External Card Reader If EM card reader or HID card reader users can be added deleted on either KZC 300 or external reader KZC 300 connected with Keypad Reader The keypad reader can be 4 Bits 8 Bits ASCII or 10 Bits output format Choose below operation according to the PIN output format of your reader Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 PIN Input format 8 4or 8 or 10 ee factory default is 4 bits Exit Exit 4 means 4 bits 8 means 8 10 means 10 digits virtual number Add PIN Users To add PIN users after entering into the program mode by infrared remote con trol PIN s can be input added on either infrared remote control or the external Keypad Reader except when the Keypad Reader is 10Bits virtual card number output the PIN s can only be input added through the Keypad Reader Delete PIN Users the same way as add users WIEGAND READER MODE KZC 300 can work as Standard Wiegand Reader connected to the third party Controller 7 3 Notes The reader can be set to read EM amp HID card or EM card only or HID card only Factory default card type is EM amp HID card if you want to change the type please set the device to Standalone Mode 7 2 and then set the type Reference 10 for setting card type All rights reserved O AAT Holding sp z o o 12 Integrated
12. tep Keystroke Combination 1 Enter Program Mode Master Code 2 Update Master Code 0 New Master Code Repeat New Master Code Master code is any 6 digits 3 Exit Program Mode Set the Working mode Notes KZC 300 has 3 working modes Standalone Mode Controller Mode Wie gand Reader Mode choose the mode you use Factory default is Standalone Mode Controller Mode Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Standalone Controller Mode 7 2 Factory default OR 2 Wiegand Reader Mode 7 3 Access standalone mode In this mode unit works as standalone controller This is factory default mode command 7 2 To change unit for Wiegand reader mode please use command 7 3 this mode is describe on next pages Connection Diagram DC Power Supply Orange DC Power Supply Grey Door Contact Dc Alarm Green Black KZC 300 U H All rights reserved AAT Holding sp z o o 6 Integrated Access Controller Installation manual AC Power Supply AC12 24V 1 Power Supply KZC 300 U H Attention When use AC power supply it must be connected with the Red wire AC1 and the Pink wire AC2 of the reader It is forbidden to connect the AC power to Black wire GND or the reader will be damaged Install a 1N4004 or equivalent diode is needed when use a common power supply or the reader might be damaged 1N4004
13. ut Can be used as Wiegand reader with LED amp Buzzer output Card block enrolment Tri colour LED status display Integrated alarm amp buzzer output Pulse mode Toggle mode User data can be transferred 2 devices can be interlocked for 2 doors Built in light dependent resistor LDR for anti tamper Low temperature resistance 40 C 9 9 99 9 9 9 99 99 99 9 SH Technical specifications User Capacity 1000 Common User 998 Panic User 2 Operating Voltage 12 24V AC DC Idle Current lt 35mA Proximity Card Reader EM amp HID Radio Technology 125KHz Proximity Card Read Range 2 6 cm Relay One NO NC Common Adjustable Relay Output Time 1 99 Seconds 5 seconds default Lock Output Load 2 Amp Maximum Environment Meets IP66 Operating Temperature 40 C 60 C 40 F 140 Operating Humidity O RH 98 RH Physical ABS Shell Colour Black KZC 300C White KZC 300B L103mm x W48mm x D20mm S1 2 X Dimensions L120mm x W48mm x D20mm S3 X L120mm x W76mm x D20mm S4 X Unit Weight 125g Shipping Weight 1859 All rights reserved Holding sp z 3 9 9 99 9 9 Integrated Access Controller Installation manual O Carton inventory C KZC 300 U H 3 Diode IN4004 For relay circuit protection e wallAnchors uuwWuWr Self Tapping Screws j Screw Driver Infrared Remote Control Master Cards UNIT INSTALLATION Remove the back cover from the un

Download Pdf Manuals

image

Related Search

Related Contents

MOBY - Habitat Automatisme  Manual - Combine  Istruzioni per l`uso dei bollitori delle serie PSM, PSR  AMX NXT-CA7  horaires (PDF 2 Mo)  E-58H, E-68, E-78 & E-88 power unit service manual  Geovision GV-BL1210  

Copyright © All rights reserved.