Home

Manuale Utente User Manual ARCLED7136

image

Contents

1. CITY CITTA CITY CITTA C ZIP CODE C A P PROV ZIP CODE C A P PROV q C CD 4 Dealer s stamp Dealer s stamp and signature and signature Timbro e firma Timbro e firma del Rivenditore del Rivenditore Purchasing date Purchasing date Data acquisto Data acquisto FORMTO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE Music amp Lights S r l ____ entertainment technologies Via Appia Km 136 200 04020 Itri LT ITALY ISO 9001 2000 tel 39 0771 72190 fax 39 0771 721955 Certified Company www musiclights it info musiclights it PROLIGHTS is a brand of Music amp Lights S r l company 2010 Music amp Lights S r l PROLIGHTS un brand di propriet della Music amp Lights S r l
2. 8 ARCLED7136 3 4 Operation in automatic mode If no DMX control signal is present at the DMX INPUT the unit independently runs through its show pro gramme provided that the blackout mode is switched off Press the button MODE so many times until the display shows AUT then press the button ENTER Press the button UP to scroll to the desired program 47 iF ATGF o AT if ATSO and press the button DOWN to switch between the modes O e F AT iG AT iF To confirm press the button ENTER The unit will operate in automatic mode Set the speed of execution programs 5FU 5925 through the buttons UP and DOWN Set the duration of execution 008 7255 through the buttons UP and DOWN 3 5 Master Slave Mode This mode will allow you to link up the units together without a controller Choose a unit to function as the Master MAST The unit must be the first unit in line other units will work as slave SLAW with the same effect Press the button MODE so many times until the display shows MA57 or SLA depending on whether you want to set the unit as master or slave Select the desired program Auto or Custom and press the button ENTER to confirm Use standard DMX cables to daisy chain your units together via the DMX connector on the rear of the units For longer cable runs we suggest a terminator at the last f
3. 10 ARCLED7136 3 4 Funzionamento in modalit automatica Se alla presa DMX non presente alcun segnale di comando DMX l unit pu svolgere il suo programma Show autonomamente Premere il tasto MODE fino a quando sul display non appare AL TE quindi premere il tasto ENTER Premere il tasto UP per scorrere al programma desiderato 47 iF ATBF o AT i0 ATEO e premere il tasto DOWN per cambiare tra la modalit O e F AT ig AT iF Per confermare premere il tasto ENTER L unit entrer in modalit automatica Impostare la velocit di esecuzione dei programmi interni SPH 1 5P25 attraverso i tasti UP e DOWN Impostare la durata di esecuzione 1008 7255 attraverso i tasti UP e DOWN 3 5 Modalit Master Slave Questa modalit consente di collegare in linea pi unit ARCLED7136 senza un controller La prima unit sar impostata come master AST e le altre funzioneranno come slave 51 7 con lo stesso effetto Premere il tasto MODE fino a quando sul display non appare 757 o SLAM a seconda che si voglia im postare l unit come master o slave Selezionare il programma desiderato Auto o personalizzato e premere il tasto ENTER per confermare Servirsi dei connettori DMX presenti sul pannello di controllo dell ARCLED7136 e di un cavo XLR per formare una catena di unit In certe condizioni e lunghezze si consiglia di effettuare una terminazione come mostrato a pagina
4. ARCLED7136 high versatility al lows for creative and spectacular entertainment lighting effects as well as for artistic architectural lighting applications ARCLED7 136 fixtures are effective tools to highlite monuments museums historical buildings and key sites as well Quality amp features of ARCLED projectors allow lighting designers architects and deco rators to express their creative imagination in different lighting environments 1 3 Technical specifications Professional RGB washlight projector based on LED technology for indoor outdoor applications Light source and optics 36 1W high efficiency LEDs 12 red 12 green 12 blue Energy saving LEDs employed with more vivid colours and lower power consumption than traditional lamps Colour synthesis RGB colour mixing gt 16million colours for a limitless colour range e High efficiency precise optics Projection angle 15 25 45 60 available on demand LEDs average life span gt 75 000 hours Electronics and features Several DMX configurations selectable 3 4 5 and 9 channels for professional or simplified controlling 3channels RGB 3 channels HSV Hue Saturation Value 4Achannels RGB dimmer e 5channels RGB dimmer strobe 9 channels RGB dimmer strobe macro auto programs programs speed ID addressing Manual control of values and programs through the LED display menu e Automatic mode with built in p
5. 000 255 4 BLUE 0 100 000 255 5 STROBO 0 100 000 255 ARCLED7136 Channel Function in ARCD mode us 1 MASTER DIMMER 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 Channel Function in ARC mode DMX 1 RED 0 100 000 255 2 GREEN 0 100 000 255 3 BLUE 0 100 000 255 13 14 ARCLED7136 4 MAINTENANCE 4 1 Cleaning the unit and maintenance Make sure the area below the installation place is free from unwanted persons during setup Switch off the unit unplug the main cable and wait until the unit has cooled down All screws used for installing the device and any of its parts should be tightly fastened and should not be corroded Housings fixations and installation spots ceiling trusses suspensions should be totally free from any deformation The main cables must be in impeccable condition and should be replaced immediately even when a small problem is detected The interior of the device should be cleaned annually using a vacuum cleaner or air jet It is recommended to clean the front at regular intervals from impurities caused by dust smoke or other particles to ensure that the light is radiated at maximum brightness For cleaning disconnect the main plug from the socket Use a soft clean cloth moistened with a mild detergent Then carefully wipe the part dry For cleaning other housing parts use only a soft clean cloth Never use
6. 13 3 6 Collegamento Si possono collegare pi unit affinch tutte le unit secondarie abbiano lo stesso effetto luce dell unit principale Master 1 Collegare l uscita DMX OUT dell unit principale con l ingresso DMX IN della prima unit secondaria ser vendosi di un cavo XLR a 3 poli 2 Collegare l uscita DMX OUT della prima unit secondaria con l ingresso DMX IN della seconda unit se condaria ecc 3 7 Modalit DMX Per poter entrare nella modalit DMX premere il tasto MODE fino a quando sul display non appare 25 Premere il tasto UP e DOWN per selezionare il valore desiderato tenere premuto invece il tasto UP e DOWN per lo scorrimento veloce Al termine dell impostazione il valore verr salvato automaticamente 3 8 Indirizzamento DMX senza indirizzo ID Per poter comandare ARCLED7136 con un unit di comando luce occorre impostare l indirizzo di start DMX per il primo canale DMX Se per esempio sull unit di comando previsto l indirizzo 33 per coman dare la funzione del primo canale DMX si deve impostare sull ARCLED7136 l indirizzo di start 33 Le altre funzioni del pannello saranno assegnate automaticamente agli indirizzi successivi Segue un esempio con indirizzo 33 di start Numero Indirizzo di Indirizzo DMX Prossimo indirizzo di start Prossimo indirizzo di start Prossimo indirizzo di start canali DMX start esempio occupati possibile per unit n 1 possibile per unit n 2 po
7. a liquid it might pen etrate the unit and cause damage to it Warning we strongly recommend internal cleaning to be carried out by qualified personnel Place Stamp Here Affrancare Via Appia Km 136 200 Music amp Lights S r l 04020 Itri LT Italy Spett le ILVDIAILYI9 JALNVYVND VIZNVYYD Id OLVIIAILYTI SIT nM 912311199 39 JUeJen6 y jo von eJuasald uo lelos passopua s aajueJenb y jo AUpijea y sasodind jje 404 uawdinba ay jo Jaumo 34140 Ayiqisuodsau 318 SJS juanbasqns pue sjsod yodsuel aajuesenb y u papnl2ul jou ase syed ajqeAaowad pue saYINMS sa puey sduue syed jeusayxq uawd nba 34130 1uewe ejda ay 104 UOISIAOIA OU sayewi SAJUBIEN y peaeduue 0 sey JUdWdINba ay JI 3AID3Ya aq 5600 ou M 6 ayy papnl2xa eale Juawd nba y Jo Huljpuey 1931103u1 pue adualadxaul Aq pasne spajag 31834411499 eseluelen6 uo a gejiene woz ay Bujpuas pue ul Bully pa1a15 631 Osje aq ued pnpoud ay 1SIYBIDISNUIMMM uo 6ul66ol y aseydund nok Jaye uoos Juswd nba jo adaid y 19351634 ol JaqUIaWUaI asea q SUOI IPUOD eelueleno jeAaua pelsqy IUSIYBIDISNUIMMM ays Q M ano uo SUOI IPUOD ealueienD Y JO UOISISA jn dy puy ue gt nop suonejnbaa Bunsixe y3m ul yun y siano gt aazuesenb ay DIZUD D6 IP 030341185 Jap auolzDJUasa d a UaWDIIUN DIDIIDAD a DIZUDI
8. custom balance of red blue and green Press the button MODE so many times until shows 7 5 and press the button ENTER to confirm Select the color red blue or green E5 TE5b TESE through the buttons UP and DOWN and then press the button ENTER Set the value XO00 X255 through the buttons UP and DOWN 10 ARCLED7136 3 11 DMX configurations L ARCLED7136 is equipped with 5 DMX configuration Press the button MODE so many times until shows MOIE and press the button ENTER to confirm Select 1X mode Select the desired DMX configuration 5786 HSV RFCS APCD APE through the buttons UP and DOWN The tables on page 12 indicate the operating mode and DMX value The ARCLED7136 is equipped with 3 pole XLR connections 3 12 Connection of the DMX line DMX connection employs standard XLR connectors Use shielded pair twisted cables with 1200 impedance and low capacity The following diagram shows the connection mode DMX INPUT DMX OUTPUT XLR plug XLR socket Pin1 GND Shield Pin2 Negative Pin3 Positive ATTENTION The screened parts of the cable sleeve must never be connected to the system s earth as this would cause faulty fixture and controller operation Over long runs can be necessary to insert a DMX level matching amplifier For those connections the use of balanced microphone cable is not recommended because it cannot trans mit control DMX data reliably Connec
9. in certe condizioni e lunghezze la sua sovrapposizione al segnale originale e la sua cancellazione La terminazione deve essere effettuata sull ultima unit della catena con connettori XLR a 5 pin o 3 pin saldando una resistenza di 1200 minimo 1 4W tra i terminali 2 e 3 cos come indicato in figura 1200 Esempio connettore XLR a 3 pin 14 3 14 Tabella canali DMX ARCLED7136 BR DMX Channel Function in STAG mode eins 1 DIMMER 0 100 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 COLOR MACRO 7 preset color effect 000 255 6 STROBE 000 255 7 AUTO program 000 255 8 Program Fade In Out time 000 128 Program run speed 129 255 9 ID ADDRESS 0 50 groups 000 255 ee DMX Channel Function in HSV mode rs 1 HUE 0 100 000 255 2 SATURATION 0 100 000 255 3 VALUE 0 100 000 255 ACLI DMX Channel Function in ARCS mode valie 1 MASTER DIMMER 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 STROBO 0 100 000 255 ARCLED7136 Channel Function in ARCD mode us 1 MASTER DIMMER 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 Channel Function in ARC mode DMX 1 RED 0 100 000 255 2 GREEN 0 100 000 255 3 BLUE 0 100 000 255 15 16 ARCLED7136 4 MANUTENZIONE 4 1 Pulizia sistema ottico e manutenzion
10. D oj maya mmy 01Y2934Dddb jap 310ssassod jap 031103 ouos nuanbasuo gt Iyasu 8 OJIOASDA Ip 35905 9 d NADA aj 2 u 116 ajodounw a appdwpj 3 8 Iod aj DIZUDID asnj gt sa u gt 5 0142234Dddb jjap auojznllsos bj apana d uou DIZUDIDD DT ossowouopw DIS dd biojonb onaya nid by uou DIZUDID o ddb jap ojvjidoiddb uou osn pp a vjzuadwul nosno IISDN s S OUOS 04334 Ins OJDJ1OdIA ojnpow JI opubinui a opubjiduio3 0301351631 319559 ond 0popodd DAIJDULAJJD u SIY IDISNUIMMM oys ns opoposd Jap 2UOIZDAISIDAA 1 p 201d Ip o3simb gt b odop 06900 5 DIZUDADY Ip D1aUaD JUOIZIPUO app 01101953 u Ip JUOIZIPUO ajjap aj01Bazu 0353 2340J NSUO ajiqissod ar s yb p snummMm OJIS NS AIJDULIOU nuabia 3 3506 ul zu o 4ado 2 poud MODEL MODELLO MODEL MODELLO CH NL SERIAL N SERIE N SERIAL N SERIE N Purchased by Acquistato da Purchased by Acquistato da SURNAME COGNOME SURNAME COGNOME 4 C VY NAME NOME NAME NOME ADDRESS VIA N ADDRESS VIA N h C J C LY
11. PROLIGHTS PROFESSIONAL LI ARCLED7136 ARCHITAINMENT LED PROJECTOR REV 002 04 10 ARCLED7136 INDICE Sicurezza Avvertenze generali Roi Attenzioni e precauzioni per installazione piaci Informazioni generali l l 4 1 Descrizione e specifiche tecniche 1 1 Elementi di comando e collegamenti ooo 5 1 2 Descrizione NG 1 3 Specifiche tecniche Z En 6 2 Installazione 2 1 Montaggio iii cacas 7 3 Funzioni e impostazioni 3 1 Funzionamento ci ors ii 3 2 Impostazione base B 3 3 Struttura del men si Miei 3 4 Funzionamento in modalit automatica pus 10 3 5 Modalit Master Slave 10 3 6 Collegamento 0 3 7 Modalit DMX uta WO 3 8 Indirizzamento DMX senza indirizzo ID pra 10 3 9 Indirizzamento DMX con indirizzo ID 11 3 10 Modalit Test ii 3 11 Configurazioni canali DMX tit 2 3 12 Collegamenti della linea DMX 2 3 13 Costruzione del terminatore DMX cc 13 3 14 Tabella canali DMX il cita A 4 Manutenzione 4 1 Pulizia sistema ottico e manutenzione 6 Certificato di garanzia CONTENUTO DELL IMBALLO ARCLED7136 e Cavo di alimentazione con spina Estensione IP66 cavo di alimentazione Estensione IP66 cavo segnale Cavo DMX input Cavo DMX output Staffa di fissaggio 2 pz Manuale utente Music amp Lights S r l si riserva ogni diritto di elaborazione in qualsiasi
12. R a 3 poli 3 12 Collegamenti della linea DMX La connessione DMX realizzata con connettori standard XLR Utilizzare cavi schermati 2 poli ritorti con impedenza 1200 e bassa capacit Per il collegamento fare riferimento allo schema di connessione riportato di seguito DMX INPUT DMX OUTPUT Spina XLR Presa XLR Pin1 Massa Schermo 2 Negativo Pin3 Positivo ATTENZIONE La parte schermata del cavo calza non deve mai essere collegata alla terra dell impianto ci comportereb be malfunzionamenti delle unit e dei controller Per passaggi lunghi pu essere necessario l inserimento di un amplificatore DMX In tal caso sconsigliato utilizzare nei collegamenti cavo bilanciato microfonico poich non in grado di trasmettere in modo affidabile i dati di controllo DMX e Collegare l uscita DMX del controller con l ingresso DMX della prima unit e Collegare quindi l uscita DMX con l ingresso DMX della successiva unit l uscita di quest ultima con l ingresso di quella successiva e via dicendo finch tutte le unit sono collegate formando una catena e Per installazioni in cui il cavo di segnale deve percorrere lunghe distanze consigliato inserire sull ultima unit una terminazione DMX ARCLED7136 13 3 13 Costruzione del terminatore DMX La terminazione evita la probabilita che il segnale DMX 512 una volta raggiunta la fine della linea stessa venga riflesso indietro lungo il cavo provocando
13. ber to register the piece of equipment soon after you purchase it logging on www musiclights it The product can be also registered filling in and sending the form available on your guarantee certificate For all purposes the validity of the guarantee is endorsed solely on presentation of the guarantee certificate Music amp Lights will verify the validity of the claim through examination of the defect in rela tion to proper use and the actual validity of the guarantee Music amp Lights will eventually provide replacement or repair of the products declining however any obligation of compensation for direct or indirect damage resulting from faultiness The information provided in this manual has been carefully checked However Music amp Lights S r l is not responsible for any possible inaccuracy ARCLED7136 1 DESCRIPTION AND TECHNICAL SPECIFICATIONS 1 1 Operating elements and connections 5 2 gt 0 3 0 7136 1 00 AUP 49 O E Fig 1 MOUNTING BRACKET LOCKING KNOB for the mounting bracket DMX OUT 3 pole XLR 1 ground 2 DMX 3 DMX DMX IN 3 pole XLR 1 ground 2 DMX 3 DMX POWER IN POWER OUT max 24 units CONTROL PANEL AND UA O 4 ARCLED7136 1 2 Description ARCLED7136 is a high tech and powerful colorchangers designed for indoor and outdoor artistic lighting applications Based on RGB color mixing system ingress protection IP66
14. del cavo di alimentazione in una presa di rete 230V 50Hz L unit pu essere comandata da un unit DMX di comando luce oppure svolgere autonomamente il suo programma Per spegnere il ARCLED7136 staccare la spina dalla presa di rete Per maggiore comodit consigliabile collegare l unit con una presa comandata da un interruttore 3 2 Impostazione base Il proiettore ARCLED7136 dispone di un LED display e 4 pulsanti per accesso alle funzioni del pannello di controllo fig 3 Nota Dopo circa 6 secondi fra due pressioni dei tasti la procedura d impostazione entra in modalit stand by PROLIGHTS PROFESSIONAL LIGHTS ARCLED 7136 0000 MODE AUP DOWNw ENTER Fig 3 MODE Per scorrere il menu principale o tornare ad una opzione del menu precedente ENTER Per entrare nel menu selezionato o confermare il valore attuale della funzione o l opzione all inter no di un menu UP Per scorrere attraverso il menu principale in ordine crescente o aumentare il valore della funzione corrente DOWN Per scorrere attraverso il menu principale in ordine decrescente o diminuire il valore della funzione corrente ARCLED7136 3 3 Struttura del men A ES gt N ES n tA lt tA ESS ANLILILS
15. e Durante gli interventi assicurarsi che l area sotto il luogo di installazione sia libera da personale non qualificato Spegnere l unit scollegare il cavo di alimentazione ed aspettare finch l unit non si sia raffreddata Tutte le viti utilizzate per l installazione dell unit e le sue parti devono essere assicurate saldamente e non devono essere corrose Alloggiamenti elementi di fissaggio e di installazione soffitto truss sospensioni devono essere total mente esenti da qualsiasi deformazione I cavi di alimentazione devono essere in condizione impeccabile e devono essere sostituiti immediata mente nel momento in cui anche un piccolo problema viene rilevato L interno del dispositivo deve essere pulito ogni anno utilizzando un aspirapolvere o un getto d aria Si dovrebbe procedere ad intervalli regolari alla pulizia della parte frontale per asportare polvere fumo e altre particelle Solo cos la luce pu essere irradiata con la luminosit massima Per la pulizia usare un panno morbido pulito e un detergente per vetri come si trovano in commercio Quindi asciugare le parti delicatamente Attenzione consigliamo che la pulizia interna sia eseguita da personale qualificato ARCLED7136 INDEX Safety General instructions RN Warnings and installation precautions suoli gaia General information 2 1 Description and technical specifications 1 1 Operating elements and connections 3 1 2 Description een A 1 3 Techn
16. e 230V Leave servicing to skilled personnel only Never make any modifications on the unit not described in this instruction manual otherwise you will risk an electric shock Connection must be made to a power supply system fitted with efficient earthing Class appliance according to standard EN 60598 1 It is moreover recommended to protect the supply lines of the units from indirect contact and or shorting to earth by using appropriately sized residual current devices The connection to the main network of electric distribution must be carried out by a qualified electrical installer Check that the main frequency and voltage correspond to those for which the unit is designed as given on the electrical data label This unit is not for home use only professional applications Never use the fixture under the following conditions in places subject to vibrations or bumps in places with a temperature of over 45 C or less than 2 C Make certain that no inflammable liquids water or metal objects enter the fixture Donot dismantle or modify the fixture All work must always be carried out by qualified technical personnel Contact the nearest sales point for an inspection or contact the manufacturer directly Ifthe unit is to be put out of operation definitively take it to a local recycling E plant for a disposal which is not harmful to the environment Warnings and installation precautions Never look directly at
17. f the bracket if is necessary Fig 2 6 ARCLED7136 3 FUNCTIONS AND SETTINGS 3 1 Operation Connect the supplied main cable to a socket 230 V 50 Hz Then the unit is ready for operation and can be operated via a DMX controller or it independently performs its show program in succession To switch off disconnect the mains plug from the socket For a more convenient operation it is recommended to connect the unit to a socket which can be switched on and off via a light switch 3 2 Basic Access control panel functions using the four panel buttons located directly underneath the LED Display fig 3 NOTE Never wait for more than 6 seconds to press the next button otherwise the procedure for setting enter into stand by mode PROLIGHTS aS PROFESSIONAL LIGHTS ARCLED 7136 0000 MODE AUP DOWNw ENTER Fig 3 MODE Used to access the menu or to return to a previous menu option ENTER Used to select and store the current menu or confirm the current function value or option within a menu UP Scrolls through menu options in ascending order or increase the value of the current function DOWN Scrolls through menu options in descending order or decrease the value of the current function ARCLED7136 3 3 Menu structure A eS gt N ES nm u lt tA Eos ANLILILS
18. forma delle presenti istruzioni per l uso La riproduzione anche parziale per propri scopi commerciali vietata Tutte le specifiche possono essere variate senza alcuna notifica 4 ARCLED7136 ATTENZIONE Prima di effettuare qualsiasi operazione con l unit leggere con attenzione questo manuale e conservarlo accuratamente per riferimenti futuri Contiene informazioni importanti riguardo l installazione l uso e la manutenzione dell unit SICUREZZA Avvertenze generali prodotti a cui questo manuale si riferisce sono conformi alle Direttive della Comunit Europea e pertanto recano la sigla Ce Il dispositivo funziona con pericolosa tensione di rete 230V Non intervenire mai al suo interno al di fuori delle opera zioni descritte nel presente manuale esiste il pericolo di una scarica elettrica obbligatorio effettuare il collegamento ad un impianto di alimentazione dotato di un efficiente messa a terra apparecchio di Classe secondo norma EN 60598 1 Si raccomanda inoltre di proteggere le linee di alimentazione delle unit dai contat ti indiretti e o cortocircuiti verso massa tramite l uso di interruttori differenziali opportunamente dimensionati Le operazioni di collegamento alla rete di distribuzione dell energia elettrica devono essere effettuate da un installatore elettrico qualificato Verificare che frequenza e tensione della rete corrispondono alla frequenza ed alla tensione per cui l unit predisposta ind
19. ghts S r l non si assume tuttavia responsabilit derivanti da eventuali inesattezze ARCLED7136 1 DESCRIZIONE E SPECIFICHE TECNICHE 1 1 Elementi di comando e collegamenti 5 a A PROLIGHTS se or 09 es DMX Signal our 3 4 y 1 00 AUP JO O A 7 SS lt Fig 1 1 STAFFA DI MONTAGGIO 2 MANOPOLA DI FISSAGGIO per la staffa di montaggio 3 DMX OUT XLR a 3 poli 1 massa 2 DMX 3 DMX 4 DMX IN XLR a 3 poli 1 massa 2 DMX 3 DMX 5 POWER IN per il collegamento ad una presa di rete 100 240V 50 60Hz tramite il cavo rete in dotazione 6 POWER OUT output alimentazione per connessione di pi unit in serie fino a 24 proiettori 7 PANNELLO DI CONTROLLO con display e 4 pulsanti per accesso e gestione delle diverse funzioni 6 ARCLED7136 1 2 Descrizione ARCLED7136 un proiettore cambiacolori LED di alta tecnologia e potenza progettato per i contesti di illu minazione artistica per interni ed esterni Dotato di sintesi di colore RGB grado di protezione IP66 consente estrema versatilit sia per l illuminazione creativa di spettacoli sia come strumento nell illuminazione arti stica architetturale L utilizzo dei proiettori ArcLed si rivela ideale per evidenziare particolari di monumenti musei edifici pubblici e siti storici con caratteristiche e qualit tali da soddisfare le capacit espressive di lighting designer architetti e progettisti ne
20. ical specifications cinco 4 2 Installation 2 MOUNTING u a 3 Functions and settings 3 1 Operation 6 3 2 Basic is 6 3 3 Menu structure SEI NERO 7 3 4 Operation in automatic mode 8 3 5 Master Slave Mode 8 3 6 Linking 8 3 7 DMX Mode ui 8 3 8 DMX addressing without ID address 8 3 9 DMX addressing with ID address ua 9 0 3 11 DMX configurations N 10 3 12 Connection of the DMX line 10 3 13 Construction of the DMX termination 11 3 14 DMX control 12 4 Maintenance 4 1 Cleaning the unit and maintenance 14 Warranty PACKING CONTENT ARCLED7136 Power cable with plug IP66 power extension cable IP66 signal extension cable DMX input cable DMX output cable Mount bracket 2 pc User manual All rights reserved by Music amp Lights S r l No part of this instruction manual may be Reproduced in any form or by any means for any commercial use Design and specifications are subject to change without notice 2 ARCLED7136 WARNING Before carrying out any operations with the unit carefully read this instruction manual and keep it with cure for future reference It contains important information about the installation usage and maintenance of the unit SAFETY General instructions The products referred to in this manual conform to the European Community Directives and are therefore marked with ce The unit is supplied with hazardous network voltag
21. icate sulla targhetta dei dati elettrici L unit non per uso domestico solo per uso professionale Evitare di utilizzare l unit in luoghi soggetti a vibrazioni o a possibili urti in luoghi a temperatura superiore ai 45 C o inferiori a 2 C Evitare che nell unit penetrino liquidi infiammabili acqua o oggetti metallici Non smontare e non apportare modifiche all unit Tutti gli interventi devono essere sempre e solo effettuati da personale tecnico qualificato Rivolgersi al pi vicino centro di assistenza tecnica autorizzato Se si desidera eliminare il dispositivo definitivamente consegnarlo Y per lo smaltimento ad un istituzione locale per il riciclaggio Attenzioni e precauzioni per l installazione Non guardare direttamente il fascio luminoso Tenete presente che i veloci cambi di luce possono provocare attacchi d epilessia presso persone fotosensibili o epilettiche Prima di iniziare qualsiasi operazione di manutenzione o pulizia sull unit togliere la tensione dalla rete di alimentazione Assicurarsi che l unit sia spenta e che la temperatura delle parti non possa provocare ustioni assolutamente necessario proteggere l unit per mezzo di una fune di sicurezza Nell eseguire qualsiasi intervento attenersi scrupolosamente a tutte le normative in materia di sicurezza vigenti nel paese di utilizzo Mantenere materiali infiammabili ad una distanza di sicurezza dall unit I filtri le lenti o gli
22. ixture see page 11 3 6 Linking Several units may be interconnected in order to control all further slave units to the same effect of the master unit 1 Connect the DMX OUT of the master unit via 3 pole XLR cable to the DMX IN of the first slave unit 2 Connect the DMX OUT of the first slave unit to the DMX IN of the second slave unit etc until all units are connected in a chain 3 7 DMX Mode Press the button MODE so many times until the display shows 25 id Press the buttons UP and DOWN to select the desired value After the setting value is automatically saved 3 8 DMX addressing without ID addressing To able to operate the ARCLED7136 with a light controller adjust the DMX start address for the first a DMX channel If e g address 33 on the controller is provided for controlling the function of the first DMX chan nel adjust the start address 33 on the ARCLED7136 The other functions of the light effect panel are then automatically assigned to the following addresses An example with the start address 33 is shown below Numberof Start address DMX Address Next possible start Next possible start Next possible start DMX channels example occupied address for unit No 1 address for unit No 2 address for unit No 3 9 33 33 41 42 51 60 For addressing without ID addressing press the button MODE so many times until shows 29 NOTE The ID address has not been set so therefore when using the contro
23. lle loro molteplici applicazioni 1 3 Specifiche tecniche Cambiacolori professionale washlight RGB a tecnologia LED per applicazioni indoor outdoor Sorgente luminosa e ottica 36x 1W LED ad alta resa luminosa 12 rossi 12 verdi 12 blu e Diodi LED ad alta efficienza con colori pi vivi e minore assorbimento energetico delle lampade tradi zionali Sistema di sintesi colore miscelazione RGB gt 16milioni di colori per possibilit cromatiche illimitate Gruppo ottico lenti antiriflesso ad alta definizione Angolo di proiezione 15 25 45 60 disponibili su richiesta Durata media diodi LED gt 75 000 ore Funzionamento ed elettronica Diverse configurazioni DMX disponibili 3 4 5 9 canali per controllo professionale o semplificato 3 canali RGB 3canali HSV tonalit saturazione valore 4canali RGB dimmer e 5 canali RGB dimmer strobo 9canali RGB dimmer strobo macro auto programs programs speed indirizzo ID Modalit manuale con selezione dei valori e dei programmi da display LED Modalit automatica con esecuzione dei programmi preimpostati Modalit Master Slave con pi unit collegate e Passaggio lineare stepless dei valori sui canali DMX Frequenza dei diodi anti flicker 400Hz Silenziosit di funzionamento proiettore privo di ventole e struttura disegnata per avere una naturale dissipazione Corpo e alimentazione e Corpo in al
24. ller channel 9 must be inactive CH9 0 ARCLED7136 9 3 9 DMX addressing with ID address Where the light control unit has not enough channels for independent management of each unit installed is still possible with the use of the ID the autonomous control unit Seton the unit as needed the same value DMX Press the button MODE so many times until shows 207 and press the button ENTER to confirm Set the ID address 200 350 through the buttons UP and DOWN The channel 9 allows to select the ID address and manage independently the unit or control a group with the same DMX value by setting the channel 9 to 0 DMX Addr 33 DMX Addr 33 DMX Addr 33 DMX Addr 42 DMX Addr 42 DMX Addr 42 ID Addr 1 ID Addr 2 ID Addr 3 ID Addr 1 ID Addr 2 ID Addr 3 DMX Controller Fig 4 The figure above shows a simple DMX layout which has used three units at each DMX address The three units have different ID addresses which allows the user to collectively control the whole group of units at that DMX address by setting CH9 0 or to control each unit independently by first selecting the DMX ad dress and the by using CH9 to locate the target ID address Example Selecting the DMX value 33 on the light controller By setting channel 9 to 0 you can control the whole group By selecting the corresponding ID address through channel 9 you can control each unit independently 3 10 Test Mode To set the
25. luminio ad alta resistenza progettato per facilitare la dissipazione termica Grado di isolamento e connessioni IP66 adattatori SHUKO e XLR3p inclusi Doppia staffa per il fissaggio in sospensione e per il posizionamento del proiettore da terra Bandiere paraluceper la regolazione del fascio ARCLED7136BD opzionali Alimentazione 100 240V 50 60Hz Output alimentazione per connessione di pi unit in serie fino a 24 proiettori a 230V Consumo 58W Peso 3 75kg Dimensioni 253x282x188mm ARCLED7136 7 2 INSTALLAZIONE 2 1 Montaggio ARCLED7136 pu essere collocato su un piano solido Inoltre grazie alle possibilit di fissaggio sulla doppia staffa fig 2 l unit pu essere montata anche a testa in gi su una traversa Per il fissaggio occorrono dei supporti robusti per il montaggio L area di collocazione deve avere una stabilit sufficiente e supportare almeno 10 volte il peso dell unit e Fissare il proiettore attraverso l apposita staffa 1 ad una collocazione idonea assolutamente necessario assicurare il proiettore contro la caduta utilizzando un cavo di sicurezza in particolare collegare il cavo in un punto adatto in modo che la caduta del proiettore non possa superare i20cm Orientare il proiettore intervenendo se necessario sulla manopola della staffa di montaggio 2 Fig 2 8 ARCLED7136 3 FUNZIONI E IMPOSTAZIONI 3 1 Funzionamento Per accendere l ARCLED7136 inserire la spina
26. nte di controllare l intero gruppo con il medesimo valore DMX ponendo CH9 0 o di controllare ogni unit in modo indipendente selezionando dapprima il valore DMX e quindi utilizzando il canale 9 per selezionare l indirizzo ID Esempio Selezionando sull unit di comando luce il valore DMX 33 Per controllare l intero gruppo il canale 9 deve essere posizionato a 0 Per controllare invece in modo autonomo una sola unit selezionare con il canale 9 il corrispondente indirizzo ID 3 10 Modalit Test Per impostare il bilanciamento personalizzato del rosso blue e verde Premere il tasto MODE fino a quando sul display non appare 7 5 7 quindi premere il tasto ENTER Selezionare il canale rosso blue o verde 7ES TESO TESE attraverso i tasti UP e DOWN Per confermare premere il tasto ENTER Impostare i valori XO00 X255 attraverso i tasti UP e DOWN 12 ARCLED7136 3 11 Configurazioni canali DMX L ARCLED7136 dispone di 5 configurazioni dei canali DMX a cui si pu accedere dal pannello di controllo Premere il tasto MODE fino a quando sul display non appare 7020 quindi premere il tasto ENTER Selezionare la modalit 57 Attraverso i tasti UP e DOWN selezionare la configurazione dei canali DMX che si desidera 57AG HSV APCS APCD APC Le tabelle a pagina 14 indicano le modalit di funzionamento e i relativi valori DMX Come interfaccia DMX l unit possiede dei contatti XL
27. rograms Master Slave mode for stand alone operations Linear and stepless transition between DMX values Flicker free operations Silent operations due to natural cooling of the peculiar chassis and to absence of fans Structure and power supply Sturdy die cast aluminum body conceived for long time durability and demanding applications IP66 protection rate and connections standard SHUKO and XLR 3p adapters included Double hanging bracket suitable for safe hanging and as a floor stand Adjustable barn doors to direct light output ARCLED7136BD not included Power unit 100 240V 50 60Hz Power output signal up to 24 units at 230V Consumption 58W Weight 3 75kg Dimensions 253x282x188 mm ARCLED7136 5 2 INSTALLATION 2 1 Mounting ARCLED7136 may be set up on a solid and even surface The unit can also be mounted upside down to a cross arm For fixing stable mounting clips are required The mounting place must be of sufficient stability and be able to support a weight of 10 times of the unit s weight e Install the projector at a suitable location by means of the mounting bracket 1 Always additionally secure the projector with the safety rope from falling down For this purpose fasten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm Adjust the projector and use the knob 2 to slightly release or tighten the locking mechanism o
28. schermi ultravioletti se danneggiati possono limitare la loro efficienza I LED devono essere sostituiti se danneggiati o termicamente deformati Non collegare il proiettore a un dimmer pack INFORMAZIONI GENERALI Spedizioni e reclami Le merci sono vendute franco nostra sede e viaggiano sempre a rischio e pericolo del distributore cliente Eventuali avarie e danni dovranno essere contestati al vettore Ogni reclamo per imballi manomessi dovr essere inoltrato entro 8 giorni dal ricevimento della merce Garanzie e resi Il prodotto coperto da garanzia in base alle vigenti normative Sul sito www musiclights it possibile consultare il testo integrale delle Condizioni Generali di Garanzia Si prega dopo l acquisto di procedere alla registrazione del prodotto sul sito www musiclights it In alternativa il prodotto pu essere registrato compilando e inviando il modulo riportato alla fine del manuale A tutti gli effetti la validit della garanzia avallata unicamente dalla presentazione del certificato di garanzia Music amp Lights constata tramite verifica sui resi la difettosit dichiarata correlata all appropriato utilizzo e l effettiva validit della garanzia provvede quindi alla riparazione dei prodotti declinando tuttavia ogni obbligo di risarcimento per danni diretti o indiretti eventualmente derivanti dalla difettosit Le informazioni riportate in questo manuale sono state attentamente controllate Music amp Li
29. ssibile per unit n 3 9 33 33 41 42 51 60 ARCLED7136 11 e Perlindirizzamento DMX senza indirizzo ID premere il tasto MODE fino a quando sul display non appare IDA NOTA Quando si utilizza un unit di controllo luce necessario assicurarsi che il canale 9 risulti inattivo CH9 0 3 9 Indirizzamento DMX con indirizzo ID Nel caso in cui l unit di comando luce non abbia canali sufficienti per la gestione indipendente di ciascu na unit installata comunque possibile con l impiego dell indirizzo ID il controllo autonomo per singola unit Impostare sulle unit in base alle necessit il medesimo valore DMX Premere il tasto MODE fino a quando sul display non appare 3 amp 7 e premere ENTER per confermare Impostare l indirizzo ID 280 1350 attraverso i tasti UP e DOWN Attraverso il canale 9 possibile selezionare l indirizzo ID e gestire in modo indipendente l unit o con trollare un gruppo con il medesimo valore DMX posizionando il canale 9 a 0 DMX Addr 33 DMX Addr 33 DMX Addr 33 DMX Addr 42 DMX Addr 42 DMX Addr 42 ID Addr 1 ID Addr 2 ID Addr 3 ID Addr 1 ID Addr 2 ID Addr 3 oor 00008000 99 SE o MIE A race Ol 6 DMX Controller 999999 Fig 4 La figura sopra mostra un semplice layout DMX con tre unita ciascuna con un valore DMX Le tre unita han no diversi indirizzi ID che consentono all ute
30. t the controller DMX input to the DMX output of the first unit Connect the DMX output to the DMX input of the following unit Connect again the output to the input of the following unit until all the units are connected in chain When the signal cable has to run longer distance is recommended to insert a DMX termination on the last unit ARCLED7136 11 3 13 Construction of the DMX termination The termination avoids the risk of DMX 512 signals being reflected back along the cable when they reaches the end of the line under certain conditions and with certain cable lengths this could cause them to cancel the original signals The termination is prepared by soldering a 1200 1 4W resistor between pins 2 and 3 of the 5 pin male XLR connector as shown in figure Example 3 pin XLR connector 12 3 14 DMX control ARCLED7136 BR DMX Channel Function in STAG mode eins 1 DIMMER 0 100 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 5 COLOR MACRO 7 preset color effect 000 255 6 STROBE 000 255 7 AUTO program 000 255 8 Program Fade In Out time 000 128 Program run speed 129 255 9 ID ADDRESS 0 50 groups 000 255 ee DMX Channel Function in HSV mode rs 1 HUE 0 100 000 255 2 SATURATION 0 100 000 255 3 VALUE 0 100 000 255 ACLI DMX Channel Function in ARCS mode valie 1 MASTER DIMMER 000 255 2 RED 0 100 000 255 3 GREEN 0 100
31. the light beam Please note that fast changes in lighting e g flashing light may trigger epileptic seizures in photosensitive persons or persons with epilepsy Before starting any maintenance work or cleaning the projector cut off power from the main supply Make certain that the fixture is off and the temperature of the components cannot cause burns Always additionally secure the projector with the safety rope When carrying out any work always comply scrupu lously with all the regulations particularly regarding safety currently in force in the country in which the fixture s being used Keep any inflammable material at a safe distance from the fixture Shields lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their ef fectiveness is impaired The lamp LED shall be changed if it has become damaged or thermally deformed Don t connect the device to a dimmer pack GENERAL INFORMATION Shipments and claims The goods are sold ex works and always travel at the risk and danger of the distributor Eventual damage will have to be claimed to the freight forwarder Any claim for broken packs will have to be forwarded within 8 days from the reception of the goods Warranty and returns The guarantee covers the fixture in compliance with existing regulations You can find the full version of the General Guarantee Conditions on our web site www musiclights it Please remem

Download Pdf Manuals

image

Related Search

Related Contents

X64 Xcelera-HS PX8 User`s Manual  resistron upt-6010 i  Manual TCF 2500.indd  USER`S MANUAL  取扱説明書 - シャープ  Cooler Master V1000  Samsung VC-8916VN Kullanıcı Klavuzu  WRL-K75 Montage- und Bedienungsanleitung  6 in. METAL FRACTIONAL  Notebook Manuel  

Copyright © All rights reserved.
Failed to retrieve file