Home
Cylinder Fill Times Troubleshooting Replacement Parts
Contents
1. MAXIMUM HUMIDITY 95 Setting the Flow Knob to the Prescribed Setting NOTE For this procedure refer to FIGURE 1 1 Attach the nasal cannula to the outlet fitting of the cylinder 2 Turn the flow knob to the L min setting prescribed by your physician or therapist A WARNING As changing the L min setting on the flow knob will affect the dose of oxygen delivered DO NOT readjust the L min setting unless directed by your physician or therapist 3 To turn the flow of oxygen Off turn the flow knob counter clockwise to the 0 position Outlet Fitting Flow Knob Prescribed Setting FIGURE I Flow Knob Invacare Corporation www invacare com USA All rights reserved Trademarks are One Invacare Way identified by and All trademarks are Elyria Ohio USA owned by or licensed to Invacare 44036 2125 Corporation or its subsidiaries unless 800 333 6900 otherwise noted Yes you can Technical Services 2009 Invacare Corporation 800 832 4707 Part No 1162100 Rev A 1 09
2. MODELS IOH2M6CH IOH2M9CH Cylinder Fill Times NOTE All filling times are approximate and may vary on environmental conditions M6 AND M9 SIZE CYLINDER CYLINDER PLATINUM 5 CONCENTRATOR FLOW FILL TIMES RATE TO PATIENT UP TO 3 L MIN IOH2M6CH 1IOH2M9CH NORMAL Ihr 25min 2hr 20min MAXIMUM Ihr 50min 2hr 45min Troubleshooting If Cylinder fails to function consult the Troubleshooting guide PROBLEM POSSIBLE CAUSE SOLUTION No flow Regulator in 0 Set to prescribed position 2 Cylinder empty 3 Dial not set at increment setting 2 Replace fill cylinder 3 Set dial so indicator points to a setting Replacement Parts Accessories M6 M9 Carrying Bag Typical Product Parameters INLET PRESSURE RANGE 300 2100 psig INTERNAL REGULATED PRESSURE 50 psig DIMENSIONS IOH2M6CH Weight 3 9 Ibs 1 8 kg IOH2M6CH Overall Length 15 0 in 38 1 cm IOH2M6CH Diameter 3 2 in 8 1 cm IOH2M9CH Weight 5 3 Ibs 2 4 kg Part No 1162100 IOH2M9CH Overall Length 14 2 in 36 1 IOH2M9CH Diameter 4 4 in 11 1 cm FLOW SETTINGS 25 5 75 1 5 2 2 5 3 4 5 6 CANNULA 4 ft recommended MS0204 7 ft long max REQUIREMENT std adult single lumen oxygen nasal cannula OPERATING CONDI TIONS TEMPERATURE O F 17 C to 105 F 40 6 C STORAGE CONDITIONS TEMPERATURE 40 F 40 C to 140 F 60 C
Download Pdf Manuals
Related Search
Related Contents
平成25年6月1日号 [PDFファイル/2.33MB] Mod:MXP-25A Tecumseh AKA7437YXAXD Drawing Data Samsung WF1600WCW/YLE Felhasználói kézikönyv Samsung T240HD User's Guide Kensington KEYFOLIO THIN X2 REFRESH BLACK マイナスイオンヘアドライヤー KHD-0920 Vision MOBILE サービス約款 Copyright © All rights reserved.
Failed to retrieve file