MA100/1 user manual
Contents
1. German unit must not be left in programming mode see ENG English chapter 7 To leave programming mode CONTROL Nur f r Servicezwecke F ae Display during input mode CALIBR Fine calibration ofthe sensor 1 2 3 4 5 6 7 8 9 101112 digit Only has to be carried out be 17 914 3 m m display SIKO 10 MA100 1 Datum 15 05 2000 Art Nr 79918 Z Nr 8664079 And Stand 160 00 No Digit Significance 12 Application Examples 1 sign blinking during incremental measurement Length measurement 2 9 mearuing value Display resolution 1 1000 mm 11 12 unitof measure Display shall be zeroed via function key 10 Trouble shooting Display Designation Progr value RESOL resolution 0 001 Error states are recognized and shown in the REF reference val 000 000 display DEC decimal point 0 000 Message OVERFLOW DIR counting direction UP Description display overrun P KEY time 1s Action check parameters and adjust them if RESET resetenable ON necessary set display to reference value ABS REL _ incr meas enable OFF Message SENSOR REF EN reference value enable OFF Description faulty no sensor signal UNITS unit of measure al Action check gap between sensor and ma BRIGHT display brightness 38 gnetic strip BAUD baudrate 19200 LANGUAGE language ENG Message Effect blinking SIGN MA100 1 CONTROL OFF cannotbe referenced CALIBR fine calibration OFF Description Display is still in incremental measurement fun
2. Parameters can be modified and checked at any time They are stored in a non volatile memory Each parameter s designation function and value range is shown in tables on the following pages To enter into programming mode Press key P for at least 1 30 s depending on key programming see below To leave programming mode Press key P until the end of the parameter list is reached To scroll parameter information Use key P To change parameters Use keys and To store modified parameters Press key then message SAVING will be briefly displayed 8 Parameter description Atthe end of this user information brochure you will find a detailed parameter list showing all programmable parameters and offering space for customer specific programming values the sensor system the sensor must be calibra pi ae Designation description ted before the first use of the system or if one system component display sensor magnetic RESOL Resolution to determine the strip is exchanged resolution of the display Dis ae play can be made in mm or For calibration please proceed as follows inch Parameter FREE al 1 Menu point CALIBR in the programming lows the programming of a menu mustbe set to ON and then confirmed by calculating factor the key FAC Calculating factor used to 2 Move sensor slowly max 10mm s over at obtain for example an angle least 10mm in one direction The
3. displayed display Basis is the 4606 values eg OC 001 004 will then not change possIo e resolunanor 1 T000 mm The calculation factor anymore which has to be programmed 3 Press key for storing measuring 4 Press key P to finish leave calibration range to be displayed total working range 1 1000 mm Example angle measurement MA100 1 Datum 15 05 2000 Art Nr 79918 Z Nr 8664079 And Stand 160 00 9 T on a circular disk with a dis play range of 0 to180 dis play in 1 100 circumference of the circular disk 942 48 mm hence total working ran ge 471 240 mm FAC 18000 471240 0 03820 fore the first use of the sy stem or if system compon ents are exchanged 9 Input mode Reset function via keyboard REF Absolute reference point for Press key to set the display to the reference the measuring system This value value is determined by cali Precondition Parameter Resetenable RE brating the system according SET in programming mode must be program to chapter 9 med to ON but unit must not be left in DEC Decimal point modification of programming mode see chapter 7 To leave the decimal point position to programming mode determine the resolution eg after programming the calcu Reset function via reference input ee nn aed as By short activation ground switching of the ee P input RESET eg by a push button or by using a DIR Direction counting direction
4. enable ON OFF UNITS mm um m cm in no units BRIGHT display brightness 4 8 15 23 38 60 100 BAUD interface s baudrate 1200 4800 9600 19200 LANGUAGE GER ENG Si KO GmbH DR ING G WANDRES Postanschrift Postal address Postfach 1106 D 79195 Kirchzarten Werk Factory Weihermattenweg 2 D 79256 Buchenbach Telefon Phone 07661 394 0 Telefax Fax 0 76 61 3 94 388 Internet www siko de MA100 1 Datum 15 05 2000 Art Nr 79918 Z Nr 8664079 And Stand 160 00
5. gt SI KO User Information MA100 1 Electronic Magnetic Display ENGLISH 1 Safety information In order to carry out installation correctly we strongly recommend this documentis read very carefully This will ensure your own safety and the operating reliability of the device Your device has been quality controlled te sted and is ready for use Please respect all warnings and information which are marked either directly on the device or in this document Warranty can only be claimed for components supplied by SIKO GmbH If the system is used together with other products the warranty for the complete system is invalid e Repairs should be carried out only at our works If any information is missing or unclear please contact the SIKO sales staff 2 Identification Please check particular type of unit and type number from the identification plate Type num ber andthe corresponding execution are indica ted in the delivery documentation e g MA100 1 0023 type number type of unit 3 Installation The unit should be used only according to the protection level provided Protect the unit if necessary against environmental influences such as sprayed water dust knocks extreme temperatures Built in housing EG Push the device into the panel 1 until the panel clips 2 hold the housing loosely Press the lateral centering 3 slightly down and push the housing into th
6. ction Action Leave incremental measurement function as descriped in chapter 9 or proceed as follows 1 Enter into programming mode 2 Program parameter ABS REL to ON 3 Leave programming mode 4 Leave incremental measurement function as descriped in chapter 8 5 Enter programming mode again 6 Program parameter ABS REL to OFF 7 Leave programming mode 11 List of commands service operation Date 30 05 1999 Software version 1 01 Parameters 1200 19200 Baud no parity 8 bit 1 stop bit no handshake Data code ASCII Com Length Reply Description mand ax 2 8 yyyyyyy CR lyyy Versionstext x 0 unit x 1 software version l 1 2 gt CR Zero setting w 1 4 abcd position value two s complement 4 by te z 1 9 Xxxxxxx CR position value ASCIll MA100 1 Datum 15 05 2000 Art Nr 79918 Z Nr 8664079 And Stand 160 00 1 Appendix Parameter list Display Designation value range Your programming Your programming II RESOL resolution 0 01 0 001 mm 0 001i 0 0001i inch FREE FAC calculating factor only if resolution has been programmedto FREE 0 00001 9 99999 REF reference value 999999 999999 DEC decimal point 0 bis 0 00000 DIR counting direction UP DOWN P KEY P Key time 1s 5s 10s 20s 30s RESET reset enable ON OFF ABS REL incrementalmeasurementenable ON OFF REF EN reference value input
7. e cut out 1 until the panel clips 2 snap completely Fig 1 Installation Bench housing TG The rubber feet can be removed in order to screw down the unit Attention Maximum screw length is 6 5 mm 4 Electrical connection e Wiring must only be carried out with power off e Provide standed wires with ferrules e Check all lines and connections before swit ching on the equipment Interference and distortion Allconnections are protected against the effects of interference The location should be selec ted to ensure that no capacitive or inductive interferences can affect the display or the connection lines Suitable wiring layout and choice of cable can minimise the effects of interference eg interference caused by swit ching power supplies motors cyclic controls and contactors Necessary steps Only screened cable should be used Wire cross section is to be at least 0 14 mm max 0 5 mm e Wiring to screen and to ground OV must be viaagood earth pointhaving alarge surface area MA100 1 Datum 15 05 2000 Art Nr 79918 Z Nr 8664079 And Stand 160 00 7 T for minimum impedance e The unit should be positioned well away from cables with interference if necessary a protec tive screen or metal housing must be provi ded The running of wiring parallel to the mains supply should be avoided Contactor coils must be linked with spark suppression e PE connecti
8. llows fig 3 No Description 1 TXD DUA 2 RXD D B 3 GND 5 Commissioning Four membrane keys onthe front panel are used for programming and operation of the display Keys function Depending on the operating mode the keys may have additional functions see Programming mode and Input mode The keys are pressed singly or in pairs two together MA100 1 Datum 15 05 2000 Art Nr 79918 Z Nr 8664079 And Stand 160 00 7 913 an gonan OO OO 1 Programming 2 Select value 3 Select digit 4 Store value Fig 4 Key functions When switched on and correctly connected e thedevicenameis displayed forapprox 1 5s the software version eg 1 00 is displayed Subsequently the specific parameters of the machine can be programmed Operating modes There are two operating modes accessible via the keyboard 1 Programming mode to program the display at initial installation 2 Input mode to enter parameters select functions used during standard operation 6 Sensor Calibration In order to minimize possible offset errors within 7 Programming mode The MA100 1 is either pre programmed to stan dard values at our works or if the order defines customer specific parameters these will be pre programmed at SIKO Enter programming mode for parameter modification programming Nor mally programming is only necessary at initial installation
9. on with 2 5 4 mm via PE clamp fig 2 Power supply is made via mains connection on rear of the device The correct supply voltage is indicated in the delivery documentation 230 VAC 10 6 or 110 VAC 10 6 or 24 VDC 20 20 Sensor connection via 9 poles rear side SUB D socket fig 2 Attention No modifiction of the sensor connec tion eg by cable extension is permitted 4 1 Connection Panel Mounting EG Ebie 456789 H HHH 8 PE 1 2 3 415 6 PEIN L Pele ele ae 2 ig gt A Se aes Se gj 2 a ei oo SS a Sissies 4119433 TRI RS232 AAS RS485 Fig 2 Pin outs EG No Pin outs 1 RESET 2 U 24V for reference switch 3 GND interface 4 NOC 5 RS232 RXD RS485 DUB 6 RS232 TXD RS485 DUA 7 PE 8 N 230 110 VAC GND 24 VDC 9 L 230 110 VAC U 24 VDC 4 2 Conn Bench Top Casing TG Reference switch Interface o 5 Hl G 9 Power 230VAC 110VAC Sensor Power 24VDC Fig 3 Rear panel connections TG Reference switch connection via a socket at the rear pin connections are to be made as follows fig 3 No Description 1 RFS 2 U 3 GND Interface connection via a socket at the rear pin connections are to be made as fo
10. proximity switch Closing contact function of the measuring system UP upward Incremental measurement DOWN downward Press key for activation P KEY Time for which P key needs The display is zeroed to be pressed to enter the programming mode e Sign blinks RESET Reset enable reset to refe Press key amp to deactivate The absolute rence value via key measuring value is displayed again ON Reset function on OFF Reset function off Precondition Menu point Incremental measu ABS REL incremental measurementen rementenable Eo RE M programming mete able must be programmed to ON but unit must not ON furicti onon be leftin programming mode see chapter 7 To OFF function off leave programming mode REREN REVA USINpUL enable Reference value modification to enter change calibration i value For reference value alteration keys P 1 must ON Reference value change on be pressed simultaneously OFF Reference value change off The display then shows the reference value UNITS Unit of measure selection which can be changed via the two arrow keys BRIGHT LED display brightness togg Press key to store the new value le MA100 1 returns to display mode if P key is BAUD Baud rate interface s baud pressed rate Precondition In programming mode menu points LANGUAGE Language Tochoosethelan Reference value input enable REF EN re guage displayed spectively must be programmed to ON but GER
Download Pdf Manuals
Related Search
Related Contents
User`s Manual Bosch 2609255920 48” LED LCD TV USER MANUAL DP-C-Serie, Fax u. Internet 取扱説明書01-08 Wave Vol.19 - 東芝情報システム株式会社 Loxit Lap-Porta 10 Samsung SR-A17NFE Kullanıcı Klavuzu Prospekt Fr. - Keller Forstmaschinen AG User Guide toUser Guide to Home Office Statistics of Copyright © All rights reserved.