Home

USER MANUAL - Electra Light

image

Contents

1. DOWN to browse other menus 2 Press ENTER to enter then press UP or DOWN and select ON or OFF showing whether using sound stimulating or not while testing ON shows to use sound controlling OFF shows not to use sound controlling controlled automatically in the testing mode After setting ON the audio singal light will twinkle together with the music in the testing procedure Pan Pan reverse in horizontal This function allows you to reverse in horizontal Press ENTER to enter use UP or DOWN if you need to reverse please select ON if you don t need to reverse please select OFF press ENTER to save and exit press ESC to exit directly Tilt tilt reverse in vertical This function allows you to reverse in vertical Press ENTER to enter use UP or DOWN if you need to reverse please select ON if you don t need to reverse please select OFF press ENTER to save and exit press ESC to exit directly Set device replacement This function allows you to restart up device to come back to original standard setting Press ENTER to confirm
2. USER MANUAL E LINE ELECTRA LIGHT o Operation guide 575 use the Digital display to control DMX address set up 575 Moving Head adopts international standard DMX 512 signal multiple lights can be controlled by the consol via address code setting the details are listed in Appendix 3 controller 512 control line control line The first light The second light The N light e The original address code set up before the products leave the factory patterns and colors streamline X Y axis is the positive direction e Use the XLR XLR cable from the signal output port of the consol to connect the signal input port of the first light connect the signal output port of the first light with the signal input port of the second light and so on until all lights are connected Then connect the terminal plug with the signal output port of the last light Figure Appendix 1 Warning Please remember the signal output of the last light should be connected with the terminal plug This plug add a resistance around 1200 between 2nd and 3rd pin of CANON plug Use this plug could effectively avoid the signal reflection created during DMX512 signal transmission 6 5 75 Moving Head Light uses 3 core XLR outlet plug A transfer line from 5 core to 3 core will be needed if the controller you use is 5 core outlet plug Please refer to Appendix 2 HMI 575W lamp is discharge lamp it is fully illuminated about 5 10
3. boards is designed for various types of computer lights equipped with multiple functions of control mode and controlled easily For some special functions which computer lights don t have the corresponding menu option set is invalid 4 USER MANUAL E LINE ELECTRA LIGHT DMX512 Address Value Setting This function let you to change the address value of the device 1 Press the ESC button once or several time until A 001 appear Then press the up or down keys to browse other menus 2 Press enter key the letter A crush out Use up or down keys to select the address value 001 512 Press ENTER to confirm exit press ESC to abandon exit 3 To accept the mainframe synchronous from the models you have to set the address value as 001 4 In the address value situations if you install DMX controller without connecting the display will twinkle if you install connecting DMX controller the display will not twinkle but the signal light will twinkle only the signal is exsit DN Pr DMX Pre Setting This function let you to choose different operating modes 1 Press the up or down keys to browse other menus 2 Press ENTER to enter then press UP or DOWN and choose nod 1 or nod 2 then press enter to save and exit or press ESC to exit directly Nod 1 mode 1 the normal channel value controlling Nod 2 mode 1 the fewer channel
4. minutes after power is on In the meantime please restart about 10 minutes after power is off 6 When power is on the equipment will undertake self examination and can undertake operation after the self examination is finished e Please don t shake the equipment during operation e Please do not use the light continuously for over 8 hours USER MANUAL E LINE ELECTRA LIGHT o Control Channel 57 5Moving Head Light adopts international standard DMX512 signal There are 12 control channels and the detailed information of control is as follow e Table of 12 control channels 6 7 9 Prism Prismrotation 0 255 Prism onirotaing prism Appendix2 The transformation between 3 core and 5 core XLR control outlet plug The following figure is the connecting method of 3 core and 5 core XLR control outlet plug 3 core plug 0 3 core plug Pin 1 nla EEN 9 Pin 1 6 ND SCREEN Pin 2 8ignal 0 0 0 Pin 2 8ignal Pin 3 8ignal Pin 3 1gnal 7 3 core plug Pin 1 GNO SCREEN Pin 2 Signal Pin 3 8ignal 3 core plug Pin 1G NO SCREEN 1 sional Pin 2 Signil Pin 4 NIC Pin SIgnal NIC 5 DMX9512 signal circuit Pin 1 screen Pin 2 signal Pin 3 signal The Instruction Manual for Computer Lightings The menu of control display
5. ELECTRA LIGHT E LINE USER MANUAL USER MANUAL E LINE ELECTRA LIGHT o Product instruction Thank you for choosing our professional 575W moving head This user guide includes very important information to guarantee the safe and proper use of the light please read carefully and operate according to the instruction This moving head light applied advanced design and processing technique adopted new type high intensity high temperature resistant engineering injected plastics With modern streamlined and beautiful outlook The product used super translucent lens and HMI575W lamp being able to create accurate bright and sharp beam with 8 rotating gobos and 8 colors stream effect plus rainbow effect performing the completely new lighting effect LED display can control DMX code and function selection built in disturbance resistant circuit and over heat protection perfect and compact construction scan angle pan 540 degree and tilt 270 degree high speed shutter flash uninterruptedly 1 11 times per second with console reset and self correction function especially suitable for TV station stage disco and nightclub 575 Moving Head light is a high tech product with perfect function It combines mechanism electron and optics and adopted international standard DMX 512 signal o Technology Parameter e Voltage AC220V 6 Frequency 50HZ 6 Power 575W HMI575 lamp Channel 12 channels e Applied modern ABS eng
6. ineer plastic housing e Digital display can be reversed 180 degree suitable for different installation 6 16Bit super smooth scan pan 540 tilt 270 8Bit or16Bit selectable scanning speed adjustable light adopted halls location realised precise location and super quiet reset overcomes noise during reset e With advanced photo electricity reset system when disturbed incidentally the light can reset automatically that is with scanning location memory function 6 Two blades strobe flash speed can reach 15Hz e Motorized focus super smooth focus adjustment 6 5 100 linear dimmer reset via controller e Can realise reset via controller e With built in program can set up program via digital display and make the light run automatically e Built in microphone music activated can realise master and slave control Directional reverse or obverse direction of x axis and y axis selectable Double gobo wheel 9 self rotating gobo blank shake e Double color wheel 9 co lour white with streamline effect e With 3 facet prism and prism rotation function e Size 48 44 x 57 cm 6 Net Weight 37Kg USER MANUAL E LINE ELECTRA LIGHT o Safety instruction Avoid the electric shock The lamp 15 high hot Please consult eligible persons before maintenance Please make sure the power supply has been cut off during installation maintenance and transportation Please do not use power supp
7. ly and lamps of different specifications During operation the high temperature the light creates might lead to danger therefore please don t put any inflammable and explosive things around the light and please don t touch the light body during operation Make sure there is more than 1 meter between the light and the irradiated objects In order to avoid harming your eyes please do not look at the light beam directly o Packing List 6 5 75 light body 2PCS 6 user manual 1PCS 0 Installation Instruction e product is suitable for indoor use only operation temperature is below 35 degree e The installation operation and maintenance persons must get familiar with the light performance before operation so that to avoid damage to the machine e Please check if there is any damage during transportation before first usage e Before changing the bulb please make sure the electric power is cut off and the lamp is cooled off Bulb temperature can reach above 200 degree e Push the maintenance cover open the small bulb lid encase the bulb please note to put the air bulb side up and please don t touch the bulb by hand e Cover the small lid e Install the product in well ventilated places and please note to check whether the fan and the fan net are unimpeded or not Connect the bicolor line yellow and green to the ground 6 5 75 moving head uses 5A 250V fuse please use the fuse of same specification
8. value controlling 3 To accept the mainframe synchronous from the models you have to pre set the DMX as nod 1 Testing Procedures This function allows you to take inner demonstration procedures without external connector This setting will be kept up If you don t exit the testing procedure you will automatically enter the testing procedure once you start up it every time Press UP or DOWN keys to browse other menus press ENTER to enter 1 nod 1 testing mode 1 Press UP or DOWN to select other modes press ENTER to enter showing RUN testing work If you need to exit please press ESC 2 NAst mainframe controlling This function allows you to test directly which don t require mainframe to send DMX synchronous singal to deputy plane Press UP or DOWN to select other modes press ENTER to enter appear ON as mainframe sending out singal the DMX singal light on Appear OFF as mainframe don t sending out singal the DMX singal light crush out press ENTER to save and exit press ESC to exit directly After setting ON you have to cut off external DMX controller which don t allow two or more mainframes with same setting in the same connecting road USER MANUAL E LINE ELECTRA LIGHT Audi Sound controlled Stimulating This function allows you to use sound stimulated testing prosecutor 1 Press UP or

Download Pdf Manuals

image

Related Search

Related Contents

Mode d`emploi - bMi  Classic 2100 manual 29/10/04dw  Assa high security lock User's Manual  タイヤ・チューブ取扱説明書  2009-2011 XRT 950 Illustrated Parts List  艦補処公示第3号 平成19年 1月19日 12V25/25S型機関  高電圧プローブ取扱説明書(PDF)    Maxima (Asiento trasero abatible)  『アメリカ EPEAT (電気製品環境評価ツール)の 最新動向について』  

Copyright © All rights reserved.
Failed to retrieve file