Z14/Z14R UseR ManUal

image

Contents

1. x PERA Negative Feed Positive Feed Negative Retum 3 Positive Return Pos BI POLAR s EARTH I Z14R Energiser configured for Bi polar operation www jva fence com e o U U m IVA Electric Fencing Products 5 4 Control Your JVA 714 security energiser has been designed for ease of opera tion Key Switch In its simplest form the energiser is controlled by the key switch on the side of the unit Keypad The energiser can be installed in a convenient location close to the fence while the keypad can be positioned in an easily accessible place The systems status information e g mains power energiser on off fence voltages fence alarm auxiliary alarm etc are displayed on the keypad If a keypad is connected the key switch and control input terminal may not be operational as they may have been disconnected by the installer If both the key switch and keypad are connected to the energiser then the last change will determine the result For example if the unit is armed via the keypad and then disarmed using the local key switch it will disarm If in doubt consult your installer For a full description of operating the Keypad see section 8 Arming the Fence Using the Keypad Enter your PIN number four digits long and push the
2. 37 76 10 11 38 7 611 Input 2 Function 12 38 7 6 12 Gate Entry Exit Delay 13 38 7 6 13 Chime Mode 14x eee ee 39 7 614 Binary Options 16 40 7 6 15 Anti Bridging threshold 17 41 7 6 16 Binary Options 2 18 41 7 6 17 Auto Re arm Time 20 42 7 6 18 Relay 44 Siren Off time 0Ox4 2505 cure S ERN xe 7 6 19 Group Mode 26d 46 8 JVAZ14LCD Keypad 48 8 1 KeypadstatusLEDs llle 48 8 1 1 Arming Disarming the Fence Using the Keypad 49 83 2 44 49 81 3 Keypad Status 49 8 1 4 Changing the Keypad Messages Address 50 8 2 To Exit Keypad 51 8 3 Connecting Multiple Keypads to a system 51 8 4 Notes Regarding Keypad 52 8 5 Calibrating the voltage 53 8 6 Summary of LCD Keypad Functions 55 Remote Control Unit 57 9 1 Fedtules audes a ec c hy hed dea ala edd era
3. Q gt U x a U st N lt gt ES IVA Electric Fencing Products Left value Right value Feed for 214 standard Z18 Feed for 214 standard Z18 Return2 for Z14 All live Z28 Return2 for Z14 All live Z28 8 Calculate the return calibration factor Actual Voltage Dis played voltage 100 100 For example If after clearing the calibration the Actual fence voltage is 7 1 but the display left value reads 6 0 as per the picture above the factor is 71 6 1 183 1 183 100 118 3 118 3 100 18 3 round up to 18 For the Left value the factor to enter is 18 an increase of 18 percent Using the same process for the Right value above picture shows 5 9kV For the right value the factor to enter would be 20 Entering new calibrations using the keypad for our example 9 Type Installer s Code 0 f Enter programming mode 10 91 8 1 8 Enter the Left calibration 11 9 9 2 0 Enter the Right calibration 12 Type Exit programming mode Note In version 7V80 the range of calibration was increased to 199 Page 54 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL 8 6 Summary of LCD Keypad Functions Use PIN SILENCE AN ALARM SINGLE ZONE SYS User PIN TEM ONLY START PROGRAMMING THE Z SERIES PIN 0 st ENERGISER Arm Zones MULTI ZONE User PIN 1 O Note 2 GROUPS User ARM Z
4. Contents Features And 8 2 1 Features 4 aux xa 64 be RAE ee RR EX EY a 8 2 2 Z14R Additional features 9 Specficatl nsces sonia a aA RRRAVEEEE ETATE a Ea a Eas 10 Description seek bok AA A k A 12 4 1 JVA ZTA see m o emo I Rm A 12 4 2 Front Panel Status 5 13 43 Front Panel LCD 13 4 4 Inputs 13 4 5 Status Codes seb GC ad Bow 13 4 6 Keypad 14 47 ZSeries 5 14 4 8 Keypad Optional 1 15 4 9 Internal Beeper Keypad 15 410 Programmable 15 411 Arm input control input 1 and Key 5 15 412 2 16 413 Low Power 16 414 Group Simultaneous Pulse 16 4 15 Remote Control Unit 16 AVG Cabling cO dn sk oi 17 417 Li
5. U LL U U A p 2 U 7a U U j U ce 7 JA Electric Fencing Products on the inner side of a window or skylight the physical barrier may be less than 1 5 m high where it covers the whole of the electric fence If the bottom of the window or skylight is within a distance of 1 5 m from the floor or access level then the physical barrier need only ex tend up to a height of 1 5 m above the floor or access level 10 4 3 Prohibited zone for pulsed conductors Pulsed conductors shall not be installed within the shaded zone shown in Figure 8 1 500mm Koy A Secure aroa B Public accoss Physkal Prohibited area 4 1 Electric socurity fonco Figure 8 Prohibited Area for Pulse Conductors Note 1 Where an electric security fence is planned to run close to a site boundary the relevant government authority should be consulted before installation begins Page 64 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL 1 920 mmmin 1 920 mmrmin 1500 mm mn Koy A Secure area B Public access aroa C Hamar whara raqured 1 Electric secunty fonco 2 Physical barrier et e o 22 D 3 D et un ot lt au D A ot M W Figure 9 Typical Constructions
6. l ad 26 6 2 Status Codes os sap ee tur E aw d RUPES 26 6 3 JUMPETS 5 55 TIT 27 64 Configuring Z14 to run in Bi Polar mode 28 6 5 Tamper Circuit Z14R 218 2 28 Installation Programming Options 29 7 1 Programming Mode 29 72 ToExit Programming 29 73 Changing the Installer PIN lt lt ee 29 74 Changing 30 7 5 Programming Options 30 76 Programming Options 32 7 6 1 Power Level 01x 2 ee ee eee 32 7 6 2 Low Power 02 33 7 6 3 Fence Alarm Voltage 03 33 7 6 4 Low Power Alarm Level 05 34 7 65 Missed Pulse Count O6x 34 7 66 Battery Alarm Voltage 07 35 7 6 7 Siren 08 36 7 6 8 Siren Off time 09 36 7 6 9 Siren Cycles 10x 37 7 6 10 11 38 9 7 6 6 Battery Alarm Voltage 07 35 7 6 7 Siren 08 36 76 8 Siren Off time 09b uuo EE 36 769 Siren Cycles 10x
7. 11x 7 6 11 Input 2 Function 12x This option is used to set the function for the Control Input Gate If set to 0 the gate alarm will trigger if the gate is opened for longer than the Gate Entry Exit Delay If set to 1 the energiser will go into Low Power Mode if this input is closed 1 Low Power Gate Input Function Low Power Mode 12x 7 6 12 Gate Entry Exit Delay 13x The gate switch must remain open for longer than the Gate Entry Exit Delay before the Gate Alarm is triggered If the switch closes within this time the Gate timer is reset to the Gate Entry Exit Delay Page 38 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL Value Notes 1 Setting 0 was changed from 10 seconds to 0 immediate in firmware version 7 77 2 From version 7 92 on Option 18 may be used to change this to a secu rity panel style entry exit delay 0 Seconds immediate me m Tm Gate Entry Exit Delay 13x ot 2 a a ze o y 3 z ET 5 W 7 6 13 Chime Mode 14x This option allows the energiser internal and keypad beeper to be used as a door chime for the gate switch When set to None the key pad beeper is used to indicate correct keypad operation only When set to Door Chime mode the beepers will sound when the gate switch opens even if the energiser is disarmed Note Gate must be selected in 7 6 11 Input 2 Function Option 12 If set to Siren the beepers
8. The bold panel in each table indicates the default value 7 6 1 Power Level 01x The power level option allows the shocking power of the fence to be adjusted For example To change the power level to maximum enter the following 019 0r0109 The keypad will beep twice to indicate that the new setting has been accepted The actual fence voltage depends on the amount of fence wire and fence conditions This setting may affect the average power drain and therefore back up battery time Power Level 01 Note In Bi Polar mode the voltage on each polarity output is 2 5kV to 4 75kV i e half conventional mode voltage Page 32 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL 7 6 2 Low Power Level 02x Same as above but for Low Power mode Low Power Level 02x ot a ct ze y zi 5 7 6 3 Fence Alarm Voltage 03 This option sets the voltage threshold below which the fence alarm will occur The default Fence Alarm Voltage is 4 kV in conventional mode and 3 KV in Bi Polar mode In Bi Polar mode this threshold is for both positive and negative fence wires www jva fence com 74 E Q m o L 42 74 lt Fence Alarm Voltage 03x 7 6 4 Low Power Alarm Level 05x This option sets the voltage threshold below which the fence alarm will occur The defa
9. code version 2 10 8 1 3 Keypad Status Display In normal operation the keypad shows a continuous summary of the system status For example if the system is disarmed the keypad will display Ready to Arm If the system is armed then the keypad will display the voltages for each zone in the system Since there can be many things to display the keypad automatically scrolls through all relevant detail Each screen is show for about 2 seconds If you wish to hold the display at a particular point simple press the key The auto scrolling will stop for about 20 seconds Pressing the key again will advance the display one step If a new trouble AC fail low battery etc or alarm occurs the keypad www jva fence com lt gt N I O A lt 0 Q TI D y et 7 TVA Electric Fencing Products screen will jump to the relevant zone the keypad will beep unless toggled off and auto scrolling will cease for about 3 minutes 8 1 4 Changing the Keypad Messages and Address You can change the messages and each of the zone labels The Dealer Message displays when the system is on standby Zone Labels displays after the i key is pressed during alarm memory or faults The programmable Service Message is displayed during AC failure communication failure or low battery 1 2 CuaRAC 3 Nor USED EMERGENCY TER UP NOT USED 4 CunsoR 5 6 Cursor FIRE NOT U
10. key Defaultis1234 sure the red ARM light comes on The keypad will beep twice to confirm that the system is armed The fence will power up and if all is well no faults the system will be ready to deter and detect o If there is a fault on the fence and it cannot achieve full volt age the LCD screen will indicate that there is a fault To disarm the system enter your PIN and press Page 22 JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL 5 5 Turning to Low Power Mode To switch to Low Power mode enter your PIN and press 41 In Low Power mode the fence will still be powered and any breach will be detected but the voltage will be much lower than normal operation The ARM light will flash in Low Power mode Enter your and press 42 to switch back to Full Power mode Alternatively the unit can be switched to Low Power mode using a switch connected to control input 2 gate if it has been programmed accordingly 5 6 When an Alarm Occurs If the system is armed and the fence is tampered with the Fence Light will flash and then remain on A siren or strobe connected to the unit will turn on If the energiser is connected to an alarm system for monitoring an alarm signal will be sent to the alarm company monitoring the alarm system An alarm will also sound if the gate input is opened and the entry exit delay time has elapsed 5 7 To Silence the Alarm Enter your and press Th
11. keypad address using one of the energisers Program each energiser with its reguired address Master address 1 Slave 1 address 2 Refer to note 4 below d Connect any control monitoring unit 12V GND and Data to the Group Master e Connect all the slaves Data and GND to the Group Master f Connect the battery and AC power of the Group Master but do not arm g Connect the battery and AC power of each slave Note Do not arm them until all the Energisers in the group are connected h Wait 5 minutes for all the Energisers to synchronise with the Master i If there are more than one keypad or control unit make sure they have a different ID then reset the group using keypad code user pin 6 8 or Perimeter Patrol Reset All this will allow both keypads to be recognised by all energisers in the group If using a PTEO210 keypad enter the key sequence 6 8 4 to automatically re scan the group and check what energisers are connected k Arm the group using keypad 1 2 3 4 1 0 4 or Page 70 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL Perimeter Patrol make sure all Energisers are activated Notes 1 Members of a group can be individually switched and off even the master can be turned off via input or key switch note that the Z14R does not have a key switch 2 slave will generate General alarm if the keypad bus is broken between it and the group master 3 Af
12. wires shall be constructed so as to ensure that these wires are positioned at a minimum distance of 150 mm from the vertical plane of the non electrified wires The barbed wire and razor wire shall be earthed at regular intervals 19 Where an electric animal fence crosses a public pathway a non electrified gate shall be incorporated in the electric fence at the point or a crossing by means of stiles shall be provided At any such crossing the adjacent electrified wires shall carry warning plates as described above 10 4 Installation of electric security fences 10 4 1 General An electric security fence should be installed so that under normal conditions of operation persons are protected against inadvertent contact with pulsed conductors Note 1 This requirement is primarily intended to establish that a desirable level of safety is present or is being maintained in the physical barrier Note 2 When selecting the type of physical barrier the likely presence of young children should be a factor in considering the size of openings 10 4 2 Location of electric security fence The electric fence should be separated from the public access area by means of a physical barrier Where an electric fence is installed in an elevated position such as www jva fence com W gt O 0 O JJ D D 3 D et W o D e et lt au D A H D gt W 7 U U
13. 11 Arm input control input 1 and Key Switch The JVA Z series energiser can be armed to energise the fence by closing a contact wired into the arm input On some models a key switch is fitted to the right hand side of the case for this purpose An external switch device for example a remote receiver or access control keypad can also be wired into the energiser to arm and dis arm the unit www jva fence com g M N 5 o U U m TVA Electric Fencing Products 4 12 Gate Input control input 2 The gate input may be wired to a gate switch to trigger an alarm when a gate is opened Alternatively it may be programmed as a control input for Low Power mode This is determined by the pro grammable option settings It is also possible to arm the gate alarm only See Section 7 6 12 for details 4 13 Low Power mode Z14 energisers can be switched into Low Power mode Low Power mode may be used in situations where the fence is not reguired to be a deterrent but is still reguired to actively detect intrusion In Low Power mode the fence live wires operate at a much lower voltage typically 500V peak See Section 8 1 1 for details on using the keypad to set Low Voltage mode 4 14 Group Simultaneous Pulse Feature In some installations it may be preferable to provide the ability to link multiple units into a group When linked the individual Z series energisers become a Group A
14. 4 hours a day 365 days a year your JVA electric security fence is monitored by an alert sober electronic watchman Once every second the JVA Z14 energiser produces a very short duration safe high voltage pulse and sends it down the fence live wires The JVA Z14 then monitors the voltage at the end of this live wire checking that the voltage is being maintained along the entire fence line In the event of a voltage drop caused by shorting cutting or poor fence maintenance the monitor will trigger an alarm alerting you to the problem Designed and manufactured to meet the most stringent international safety standards the JVA Z14 is in a class of its own when it comes to features and benefits at an affordable price JVA Technologies Pty Ltd Z14 Z14R MANUAL 2 2 2 et o A ct o 5 www jva fence com ne U U lt 17 U 2 2 U LL Features And Benefits AUSTRALIAN DESIGNED AND MANUFACTURED PROGRAMMABLE OPTIONS WALL MOUNTABLE ROBUST ENCLOSURE WITH EASILY DETACH ABLE CHASSIS INBUILT LCD VOLTAGE DISPLAY AND STATUS LIGHTS INTERNAL ZAH 12V RECHARGE ABLE BATTERY OPrioNAL LCD OPTIONAL PC AND INTERNET CONNECTIONS Low PowER MODE SWITCHED 12V OUTPUTS FOR SIREN AND STROBE EARTH MONITOR INPUT ENCLOSED FENCE TERMINALS More Features IVAN Electric Fencing Products HIGH RELIABILITY AND GREA
15. A Electric Fencing Products 8 JVAZ14LCD Keypad Features U gt U LL O gt 4 x e U st N lt gt 8 1 Keypad status LEDs The LCD keypad has two LEDs Power and Arm which act as follows e Power On with Mains power flashes on low battery Arm On When the energiser is armed pulsing flashes when in Low Power Mode Page 48 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL 8 1 1 Arming Disarming the Fence Using the Keypad Enter your User PIN Personal Identification Number four digits long and push the key Make sure the red ARM light comes on and the keypad beeps twice to confirm that the system is armed The fence will power up and if all is well no faults the system will be ready to deter and detect To disarm the system enter your User PIN and press Note If there is an alarm sounding you will need to enter your PIN twice once to silence the alarm and once more to disarm 8 1 2 Menus 7 series keypad has an optional menu driven interface The main menu is accessed by pressing the Menu Bypass key bottom right You will be asked to enter your PIN and then press Most functions are available via the menus Use the 2 key to go up and the 8 to step down through a menu The Enter key is used to select the current line The menu will time out after a few minutes and return to the normal status display The menu system was added in keypad
16. Bi Polar 8 Joule contains relays and IR Tamper circuit Z28 Dual Zone conventional 8 Joule 4 Joules per zone ZM1 Single zone start of fence monitor with Distant Fault Detec tion ZM20 Twenty sector loop monitor Note A Z14 configured for Bi polar may be referred to as a Z14A e o U U 14 JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL 4 8 Keypad Optional The Z series LCD keypad allows for easy remote control of your JVA energiser Arming and disarming responding to alarms or just check ing the fence voltage the LCD keypad makes this easy through a simple menu system or key sequences shortcuts Your security is protected by a user PIN number A keypad is also required to program the programmable options see Section 7 For information on how to control the Z14 via the keypad see Sec tion 8 1 1 4 9 Internal Beeper Keypad Beeper Depending on the chime setting the internal beeper and keypad beeper will sound when there is a fence alarm a gate alarm a door chime or a general alarm Should the battery voltage run low the keypad will beep 4 times before the energiser automatically enters Low Power mode to preserve the battery 4 10 Programmable Options The Z14 has many programmable options These are also known as setup parameters To alter these options a keypad must be used The options are explained in Section 7 6 Each parameter has a factory set default 4
17. E OUTPUTS TO AN ALARM PANEL 16VAc 3Way 16VAc 1 5A POWER INPUT PLUS EA THE EARTH IS ONLY REOUIRED WHERE ING CODES DEMAND IT THIS SHOULD CABINET OR MAINS EARTH NOT THE SHOULD USED RTH CONNECTION OF LOCAL SAFETY OR WIR BE CONNECTED TO THE FENCE EARTH 2Way 12V DC OR BATTERY CONNECTION V TABLE FUSE AND FLYING LEADS 6 1 Power Options The Z14 has 2 sources of power 16VAC and 12VDC Battery solar power and an external battery connect the battery to tery leads not the 16Vac input F1 3 RESET If using the bat A 24Vdc 1 5A supply can be used in place of the 16Vac supply The correct connection is 24V to the mid AC pin GND to the left AC pin Due to the stored energy in a 24Vdc plug pack an AC Fail may take up to 5 minutes to be reported NOTE Use only rechargeable batteries 6 2 Status Codes Status Codes Page 26 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL If a minor error occurs it will self clear if the error condition is re moved If the mains fail or the battery runs low it will not disarm the energiser However without mains power the battery will eventually be depleted and the energiser will attempt to maintain operation by entering Low Power mode after 4 warning beeps If the battery charge continues to fall the energiser will eventually stop Once mains power has been restored and the battery has recovered the energiser will rearm itself aut
18. ME THE AMOUNT OF TIME THE SIREN WILL BE OFF FOR AFTER THE ON TIME HAS EXPIRED 10 SIREN CYCLES THE NUMBER OF TIMES THE SIREN WILL SOUND FOR THE ON TIME FUNCTION ABOVE AFTER THIS MANY CYCLES THE SIREN WILL AUTOMATICALLY MUTE INPUT INVERSION CLOSED TO ARM OR OPEN TO ARM Gate INPUT FUNG GATE SWITCH MODE Low Power SwircH TION MODE Gare Exit DELAY TIME FROM GATE SWITCH OPENING TO ALARM 14 CHIME MODE ALLOWS THE KEYPAD AND INTERNAL BEEPER FUNCTION TO BE ALTERED Binary OPTIONS MISCELLANEOUS OPTIONS 17 ANTI BRIDGING IF THE VOLTAGE RISES OR FALLS QUICKLY BY MORE THAN THIS SETTING AS A PERCENTAGE OF THE AV ERAGE FENCE VOLTAGE THE ALARM WILL OCCUR Binary OPTIONS 2 MISCELLANEOUS OPTIONS Auto RE ARM TIME SETS THE TIME WHICH MUST ELAPSE AFTER AN ALARM HAS TIMED OUT COMPLETED THE SIREN CYCLES BEFORE THE UNIT WILL AUTOMATICALLY RE ARM READY FOR THE NEXT ALARM EVENT 21 OPTIONS PROGRAM THE RELAY OUTPUTS TO FOLLOW 25 CERTAIN CONDITIONS OF THE ENERGISER FOR EN HANCED MONITORING PURPOSES 26 Group ID ALLOWS THE ENERGISER TO BE SET AS A MAS TER OR SLAVE IN A SYNCHRONISED GROUP NOT AVAILABLE IN ALL MARKETS Programming Options ot 2 a et ze o y 3 3 5 Er 5 W www jva fence com 74 E Q S m o E ES 76 42 174 lt OVA Electric Fencing Products 7 6 Programming Options in Detail NOTE
19. ONE X WHERE X IS ANY ZONE User NUMBER UP TO 15 Use PN Disarm ZONE X WHERE X IS ANY ZONE User PIN 2 x 4 NUMBER UP TO 15 SWITCH TO LOW POWER MODE ALL User PIN 4 1 ZONES SWITCH TO HIGH POWER MODE ALL User PIN 4 2 ZONES PNA NOS TO CHANGE THE KEYPAD MESSAGES TO ENGLISH SPANISH lt gt N S O A D lt W TI ot m 1 www jva fence com JA Electric Fencing Products KEYPAD ALARM BEEPER CHIME ON 5 3 Orr BACKLIGHT MODE ON ON WITH KEYS 8 Orr 118 8 RESET AND DISPLAY FIRMWARE VER User PIN 6 8 Norte SION NUMBER FAULTS Notes 1 Operates while in programming mode only 2 The group arm and disarm codes were added in version 7 5 of the firware 3 Added in firmware version 7 69 Battery test will only operate while the Energisers is disarmed 4 Addedin firmware version 7 77 5 Addedversion 786 6 Added version 7 89 U gt m U LL Q A U x a U st N lt gt ES Page 56 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL 9 Remote Control Unit The Remote Control Unit provides the Z14 with the ability to arm or disarm the energiser via a compact key chain fob remote control Two remote controls are provided and are uniguely coupled to the
20. SED LEFT MESSAGE RIGHT 7 8 CuaRAC 9 PANIC NOT TER DOWN USED 0 LAST E BYPASS NOT MESSAGE USED Keys used for changing messages To activate the keypad programming mode enter the In staller s Code 0 1 Information may be entered into the key pad in the form of letters upper and lower case numbers 0 9 and 22 special symbols All characters are displayed in the order upper and lower case letters numbers and special symbols The Space character precedes the letter A U gt m U LL Q A U x a U s N lt gt enter a Label use the 2 key to scroll through the char acters until you reach the desired character If you scroll past the de sired character the 8 key may be used to scroll backwards NOTE The space character is before the A character When A is displayed press 8 to get a space Page 50 JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL When the desired character is displayed press the 6 key to move the cursor to the next character position The 4 key moves the cursor to the left When all characters have been entered press the key to enter the message and move to the next message position Use the 0 key to move backward through the messages NOTE If you move to the next message using 5 instead of the key you will lose any changes you made To change the keypad address s
21. T SERVICE CUSTOMISE THE ENERGISER TO UNIQUE FENCE CONDITIONS EASE OF INSTALLATION AND REPAIR SEE FENCE CONDITIONS AT A GLANCE ENSURE CONTINUED OPERATION OF YOUR SECURITY ELECTRIC FENCE IN THE EVENT OF A MAINS POWER FAILURE EASE OF CONTROL AND DISPLAY OF FENCE VOLTAGES INTEGRATION WITH SECURITY INFORMA TION MANAGEMENT SYSTEMS DETECTION TOGETHER WITH REDUCED VOLTAGE FOR DURING THE DAY LOCAL AUDIBLE AND VISUAL INDICATION ALERTING USER TO BREACH OF SECURITY ENSURES THAT ALL THE WIRES ON THE FENCE ARE MONITORED CONTINUALLY TAMPER RESISTANT AND PREVENTS ACCI DENTAL CONTACT WITH HIGH VOLTAGE Meets Safety EMC standards reports available on request Powerful 4 joules peak output energy High and low Power mode Page 8 O JVA Technologies Pty Ltd 2 2 JVA Z14 Z14R MANUAL High and low Power mode Built in charger and space for a 12V 7 2aH backup battery Alarms on fence short or open circuit Control and programming via LCD keypad Monitor via PC using Perimeter Patrol software Internal beeper AC fail Low Battery and Bad Battery detection Large number of keypad programmable options Adjustable fence voltage level Can be configured as conventional OR Bi Polar Two Control Inputs which can be configured to take NO or NC contacts Two 12V driven Outputs also referred to as Relays Z14R Additional features Three C Relays with dry contacts or switched voltage Output Relays
22. aller s code 0 4 4 Enter 26 followed by the required value e g 1 for master then 5 Enter to exit programming 6 Connect the group using the keypad bus as the Group Mode Linking diagram Note At this time groups are limited to a master and 14 slaves 15 zones total www jva fence com W gt O O 2 D j gt W o ot lt m A gt 7 U U U LL U U gt 2 U U Y U j U a as m 5 7 ME Electric Fencing Products Group linking via the Keypad bus The keypad terminals on all Energisers in the group are linked see Figure 16 Since only one Energiser needs to power the keypad 3 wires are linked from one Energiser preferably the Master to the keypad optional and 2 wires to every other Energiser in the group Do not connect the lines between Energisers as this could result in some strange behaviour and possibly damage Note the connections can be a star or daisy chain or any mixture It is possible for a PC to be added to the group using a keypad to RS232 adaptor PAE051 We recommend following these steps in the right order a Disarm all energisers in the group If energisers are not disarmed Step 10 may not work correctly b Program the
23. croll through the messages until the keypad displays Keypad address __ then change the value by pressing 2 up or 8 down Validate by pressing The message order is SERVICE MESSAGE Displayed under System Trouble Press ug DEALER MESSAGE Displayed under the standby message Ready to Arm ZONE NAMES BAUD RATE should be left at 2400 KEYPAD ADDRESS should be left at 1 8 2 To Exit Keypad Programming When you have finished programming press NOTE The keypad will also exit the programming mode if you do not press any key within a five minute period To return the Keypad to default settings press the emergency button during power up This feature was added in keypad firmware version 1 2 8 3 Connecting Multiple Keypads to a system Up to three keypads may be used to remotely monitor and control the Z series security energisers www jva fence com lt gt N I O A lt 0 o TI D y et 7 U U LL gt U x U N lt gt m TVA Electric Fencing Products To operate correctly each Keypad must be configured to use a unique KEYPAD ADDRESS This is best achieved by connecting one keypad at a time to the Master Energiser and updating the KEYPAD ADDRESS Once all Keypads have a different address all can be con nected to the system A recommendation is that one Keypa
24. d is kept at ADDRESS 1 The Energiser now needs to be introduced to all of these Keypads This is achieved by resetting the Energiser using the Keypad config ured to ADDRESS 1 by pressing USER PIN 68 Alternately the pow er can also be removed to reset the Energiser After a reset the En ergiser will determine what Keypads are connected and only these ADDRESSES will be used in the future This prevents un authorised Keypads being added to the system once it is running If the security system is to use a PC based interface such as Perimeter Patrol KEYPAD ADDRESS 2 should not be used by a keypad The PC software uses this address to control the Energisers 8 4 Notes Regarding Keypad Configuration Zone 1 the master must be connected to the group If it is not con nected the other energisers in the group will not send status packets to the keypad The status packets contain voltage and alarm infor mation which the keypad displays If Zone 1 is not connected the keypad will report a communications failure with all the zones A Slave Energiser disconnected from the Group will only talk to a Keypad if it has a KEYPAD ADDRESS of 1 When adding removing an energiser to from the group be sure to re analyse the group using the key sequence 68 Zone 1 the master must be connected to the group for this operation to work When re analysing a group ensure all energisers are disarmed If they are not this function will not work proper
25. ds eae 4 57 9 2 Installations z xz XAR y OUR EX X WES 58 93 Operation and 59 10 Standard Reguirements for Security Electric Fences 59 10 1 Definitions oz 20424 ko G4 884 454545 oe E Res 59 10 2 General requirements for electric fences 60 10 3 Particular requirements for electric animal fences in Australia 62 10 4 Installation of electric security fences 63 E U Ke lt TVA Electric Fencing Products 1 Page 6 Introduction Thank you for purchasing a JVA security electric fence energiser The growing use of non lethal electric security fences around the world is indicative of the confidence security professionals are placing in this form of perimeter security The reason for this popularity is simple monitored electric security fences are effective and they reduce false alarms when compared to other technologies DEMARCATION The JVA electric fence around your property shows you mean business DEFLECTION Intruders are deflected to softer targets DETERRENCE The safe powerful JVA shock is a strong deterrent to intruders DELAY The barrier will help delay an intruder giving you more time to react DETECTION JVA s voltage monitor warns you of any tampering with the fence DEPENDABLE 60 seconds a minute 60 minutes an hour 2
26. ef fectively insulated from the earthed structural parts of the building This may be achieved by using insulated high voltage cable 9 Connecting leads that are run underground shall be run in a conduit of insulating material or else insulated high voltage cable shall be used Care shall be taken to avoid damage to the connecting leads due to the effects of animal hooves or tractor wheels sinking into the ground 10 Connecting leads shall not be installed in the same conduit as the mains supply wiring communicating cables or data cables 11 Connecting leads and electric fence wires shall not cross above overhead power or communication lines 12 Crossings with overhead power lines shall be avoided wher ever possible If such a crossing cannot be avoided it shall be made underneath the power line and as nearly as possible at right angles to it www jva fence com W gt O 0 O JJ D D 3 D et W o D e et lt au D A H D gt W 7 U U en U LL U U gt p U c i U U as 7 OVA Electric Fencing Products 13 If connecting leads and electric fence wires are installed near an overhead power line the clearances shall be not less than those shown in table Minimum Clearances from Power Lines 14 If connect
27. ghtning 17 418 Earth Loop 0 17 419 17 420 PCCOntOl sac goce deere de heen ee RE 18 4 21 Web SEINE os aei m dede d ka eres abate eee oa ee 4 18 doe eo ARE CREE AER 18 5 1 Installation Steps RR RU Y ERR 18 52 JVAZ14 Interior 20 5 3 Examples of Fence High Voltage Wiring Diagrams 21 5 4 OME cree ca de me 422 22 5 6 7 5 1 Installation Steps 18 52 JVAZ14 Interior 20 5 3 Examples of Fence High Voltage Wiring Diagrams 21 54 Control des 22 5 5 Turning to Low Power 23 56 Whenan Alarm 23 5 7 ToSilence the 23 58 Changing the 24 5 9 Standby 24 510 Status 24 Technical Information 25 6 1 Power Options z z jod lp
28. gies Pty Ltd JVA Z14 Z14R MANUAL the inside of the Energiser lid needs to have a small piece of reflective material above the IR tamper circuit 7 Installation Programming Options The Z14 has a non volatile memory in which are held programming options setup parameters These are factory pre set but can be field programmed using a keypad 71 Programming Mode To enter Programming mode enter the 6 digit installer PIN followed by 0 keys The keypad will beep twice to indicate that the com mand was accepted If the PIN was incorrect the keypad will beep 3 times Pressing the key will cycle through all the options on the LCD NOTE Not all option numbers are used The default installer PIN is 0 12345 7 2 To Exit Programming Mode After programming press to exit If left unattended the unit will time out and auto exit Programming mode after approximately 5 minutes 7 3 Changing the Installer PIN The installer PIN may only be changed while in Programming mode To enter a new installer pin press 00 followed by the new 6 digit PIN then the key If you cannot remember your installer or user PIN return the unit s memory to default To do this remove power AC off and disconnect the battery open the energiser remove jumper J4 and reconnect the battery for about 10 seconds Re fit J4 www jva fence com 7 ect D o 5 g y 3 5 gt 7 TA Elect
29. his function is latched Strobe As per Siren but does not time out will remain On until both Zones are switched off This function is latched AC Fail Alarm on AC Fail Alarm on low or bad battery Alarm when the lid is up and J3 is not fitted Group wide Group relay functions are the collected status of the x whole group of Z energisers Group Armed for example is set only if all energisers in the group are armed Relay Options Explained 7 6 19 Group Mode 26x A group must have only one master The other Energisers in the group are slaves Group Voltage display energisers require each slave to have a different number Since the keypad bus is common among the group one keypad can be used to program all units for all options except this Group Mode for obvious reasons The procedure is Connect the keypad to each unit in turn before linking all Energisers into a group Set the option one unit as master the other as slaves NOTE At this time groups are limited to a master and 14 slaves In some markets Group Mode may not be available For details on group wiring and operation see APPENDIX A 2 Q m o LD 74 lt Page 46 JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL etc etc Slave 14 Group Mode 26 ot 2 D ct 5 ze o y 3 3 Et 5 www jva fence com J
30. ing leads and electric fence wires are installed near an overhead power line their height above the ground shall not exceed 2 m This height applies either side of the orthogonal projec tion of the outermost conductors of the power line on the ground surface for a distance of 2 m for power lines operating at a nominal voltage not ex ceeding 1 000 V 15 m for power lines operating at a nominal voltage exceed ing 1 000 V 10 3 Particular requirements for electric animal fences in Australia 15 A distance of at least 10 m shall be maintained between the energiser earth electrode and any other earthing system such as the power supply system protective earth or the telecommunication system earth 16 Electric fences intended for deterring birds household pet containment or training animals such as cows need only be supplied from low output energisers to obtain satisfactory and safe perfor mance 17 In electric fences intended for deterring birds from roosting on buildings no electric fence wire shall be connected to the en ergiser earth electrode A warning plate as described above shall be fitted to every point where persons may gain ready access to the Page 62 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL conductors 18 non electrified fence incorporating barbed wire or razor wire may be used to support one or more off set electrified wires of an electric animal fence The supporting devices for the electri fied
31. irements for Security Electric Fences 10 1 Definitions Connecting lead An electric conductor used to connect the energiser to the electric fence or the earth electrode Electric animal fence An electric fence used to contain animals within or exclude animals from a particular area Electric fence A barrier which includes one or more electric conductors insulated www jva fence com ot ry 5 o o 22 D 3 D et un c ot lt D A ot M W 7 U U U LL U U gt 2 U U Y U j U a as m 7a ME Electric Fencing Products from earth to which electric pulses are applied by an energiser Electric security fence A fence used for security purposes which comprises an electric fence and a physical barrier electrically isolated from the electric fence 10 2 General reguirements for electric fences 1 Electric fences shall be installed and operated so that they cause no electrical hazard to persons animals or their surroundings 2 Electric fence constructions which are likely to lead to the entanglement of animals or persons shall be avoided 3 INSTALLERS USERS SHOULD NOTE WARNING Avoid con tacting electric fence wires especially with the head neck or torso Do not climb over through or under a multi wi
32. iren Off Time has passed The default is 3 minutes This may be the subject of local regulations to stop an alarm causing undue disturbance to neighbours etc NOTE The Siren On Time will be cut short if the battery falls below the low bat tery level s Mmm E me Tome Siren On Time 08x 7 6 8 Siren Off time 09x This option sets the amount of time the siren will be Off for after the Siren On Time above has expired If an alarm is still present after this Off time the siren will sound again Page 36 JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL 10 Seconds 9 ome Siren Off Time 09x 7 6 9 Siren Cycles 10x This option sets the maximum number of times the siren will sound for the On time if the alarm continues This may be limited by local regulations to stop an alarm causing undue disturbance to neigh bours etc NOTE This is the maximum number of cycles for 1 continuous alarm intermit tent alarm events could cause more than this number of siren soundings et D 5 g o Ce 3 z 5 5 www jva fence com 74 E Q S o E ES 76 42 74 lt Siren Cycles 10 7 6 10 Input Type 11x The control inputs can be inverted Unless an input is used for a Gate switch in which case it is always NC 1 NC Normally Closed Input Type
33. is will silence the alarm but not disarm the system the Armed Light will still be on The sys tem will be ready for the next alarm Note that the following functions have an effect on alarm timing Siren On time Siren Off time Siren Cycles Auto Re arm time The siren and strobe are ready to respond again if triggered To disarm the system enter your PIN and press again This will also clear the fence alarm light Alternatively disarming using the key switch will reset the alarm e If you silence an alarm and the problem is still present when the unit is rearmed the siren will sound again off time after www jva fence com g M N 5 Q U 74 U o IVA Electric Fencing Products the programmed off time has elapsed 5 8 Changing the PIN Number Enter the old PIN and press 0 This enters User Program ming mode Enter your new PIN must be 4 digits and then Repeat to confirm PIN Press to exit User Programming mode Make sure your new PIN works by using it to arm the ener giser default PIN is 1 2 3 4 5 9 Standby Battery Should there be a loss of mains power the Power Light on the key pad will go off If the loss of power is prolonged the battery may discharge power and become ineffective The Power Light will start to flash indicating a battery low power problem If the battery is fully depleted the unit will not pul
34. ly Page 52 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL Note If the group ID has recently been changed you may need to reset PIN 68 before the new ID s will be properly reported to the keypad 8 5 Calibrating the voltage display The PCB s will be factory calibrated and should not require adjust ment for the life of the product If however certain components are replaced during repair the Energiser may need recalibration This in cludes the main processor chip Procedure 1 On the energiser connectors connect Return to Feed terminals and Earth Return to Earth Feed terminals 2 Plug in the keypad power the unit and turn on the energiser using the key switch Clearing old calibration using the keypad 3 Type Installer s Code 0 Enter programming mode 4 Type 9 8 0 0 Clear the calibration for the Left value Type 9 9 0 0 Clear the calibration for the Right value 6 Type Exit programming mode 7 Once the calibration is cleared run the energiser and record the actual voltages produced by the energiser using a fence meter Record the values displayed on the LCD The actual voltages must be higher than the values displayed on the LCD for calibration to work SS S S 5 5 5 5 5 5 5 5 5 0 5 0 55 5 5 L S SAN S A www jva fence com lt gt N I O O A lt 0 Q TI D y et 7 U x gt m U LL
35. may be assigned to any alarm function Infrared tamper beam disables the Energiser if the lid is removed Approved for sale in Australia and New Zealand Electrical Safety Approval www jva fence com 7 W 2 gt 5 O MD zh d W TA Electric Fencing Products 3 Specifications ENERGISER OurPUT VOLTAGE 9 5KV PEAK NO LOAD PEAK OurPur ENERGY 4 Joules 500 5 Purse RATE LockED AT 0 8 Hz 12 Dc Power CONSUMPTION ENERGISER ON 550MA AVERAGE 700MA PEAK ENERGISER OFF 28MA 40 WITH KEYPAD NOT INCLUDING KEYPAD OR AUXIL IARY POWER BaTTERY CHARGER OUTPUT Float VOLTAGE 14V 500MA SHORT CIRCUIT AND REVERSE POLAR ITY PROTECTION SIREN AND STROBE OuTPUTS SELF RESETTING FUSE PROTECTION SWITCHED 12V RATED AT 30W COMBINED SIZE 300mm HIGH 190MM WIDE 115 DEEP WEIGHT PACKED NO BATTERY 1 9 4 c rm U E U o V WARNING Page 10 JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL There are no user serviceable parts in this unit The installer is reminded that high voltages are retained for a while after switching off and to wait for at least 10 minutes before opening the case Before working on the high voltage wiring of an electric fence it is recommended that the energiser be turned off and an intentional short circuit be placed from the fence live wires to earth Electric fences are not toys do not let children play with
36. mimic the siren function Gate Beeps plus Siren will give 2 beeps on Gate open and 4 on close plus continuous for an alarm Beeps are on Keypad only not internal beeper www jva fence com 74 E Q S m o E 76 74 lt electric Fencino Products 0 Mne Gate beeps plus Siren Chime Mode 14x 7 6 14 Binary Options 16x Each option in this table can be turned on by adding the correspond ing value For option 1 set 16 to 01 for 1 and 2 set 16 to 03 1 Enable cross coupled alarm not used on Z series Energisers 2 Maximum power at all times Note turning this option on may remove IEC standards compliance Added in code version 7 80 4 Limits outputs to 2 5 Joules per Zone on a 728 Added in code version 7 84 Also limits a Z14 to 2 5J per zone in group mode Added 7 86 8 Enables the IR tamper detection under the lid J3 changes func tion to inhibit tamper 16 Stop slaves on E 16 Coms Fail if the communications from the group master is lost 32 Stops the energiser sending Alarm Memory to a PC relay PCB or keypad Set this to restore unlatched mode on a PAE201 relay PCB Note 8 and 16 added in code version 7 86 32 added in code ver sion 7 87 oo Too CEN Cross couple alarm 2 5 Joules Limit Page 40 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL IR Tamper enabled 16 Stop slave on co
37. ms fail 32 Do not send Alarm memory Binary Options 16x 7 6 15 Anti Bridging threshold 17x Anti bridging has been designed to detect a section of fence be ing bypassed and removed from circuit by an intruder bridging the feed to returns together and then cutting the live wires in between Setting this option to a value greater than 0 default is 0 off will en able Anti bridging however this feature will not operate in low pow er mode While Armed a Fence Alarm will trigger if the Fence Volt age rises OR falls quickly by more than the threshold A slow change to the voltage will not trigger a Fence Alarm until the Voltage is less than the Fence Alarm Voltage 03x The Anti bridging Threshold is a percentage value of the current Fence Voltage For Example setting option 17 to 10 1710 will set a 10 Anti bridging Threshold At this level a fence return volt age normally reading 7 5kV will trigger a Fence Alarm if the voltage quickly rises to over 8 3kV or falls to less than 6 7kV NOTES 1 Power Level Option 1 must be set higher than the normal fence run ning voltage otherwise if the load is released fence bridged voltage control will limit the voltage rise and the anti bridging alarm would not activate For the above example Option 1 must be set to 7 or greater to allow the un loaded fence to rise to 8 3kV or higher thus triggering the Alarm 2 A minimum of 5 was added in code version 7 92 7 6 16 Bi
38. nary Options 2 18x Each option in this table can be turned on by adding the correspond ing value www jva fence com ot 2 D a 5 ze o y 3 zi EC 5 W 74 Q S m o ES 76 74 lt TA Electric Fencing Products Each option in this table can be turned on by adding the correspond ing value For option 1 set 18 to 01 for 1 and 2 set to 03 1 Enable Siren Acknowledge The siren will chirp once for armed and twice for disarmed 2 Enables a home alarm style entry exit delay for the gate input See also option 13 4 Sets the keypad bus baud rate to 4800 default is 2400 all units in a group PC and Keypad must be set to the same baud rate The change will not take effect until after a reset 8 Sets the keypad bus baud rate to 9600 default is 2400 Note Z11 defaults to 1 Note 2 4 and 8 were added in code version 7v92 o ooo o ooe OO O O NE HEN E a Binary Options 2 18x 7 6 17 Auto Re arm Time 20x This option sets the time which must elapse before another alarm will sound after the first alarm has timed out gone completely through its cycles without being turned off If an event occurs such as a low fence voltage which triggers the si ren any other events which would otherwise trigger the siren such as a gate alarm will be ignored while the siren is so
39. not polarity sensitive Do not connect a live or neutral to the earth terminal Replace the front cover Turn AC power on Arm and disarm the energiser via the keyswitch or keypad if fitted The Status Light should stop blinking Arm the unit Check to ensure that a short anywhere on the fence triggers the alarm Ensure that the user understands how to change the user code PIN and is in possession of this Installer User Manual and the installer s contact details NOTE Keep high voltage and low voltage cables at least 30mm apart Do not run high and low voltage cables in the same conduit qualified technicians www jva fence com g M N 5 JAS Electric Fencing Products 5 22 JVAZ14 Interior Configuration 2O o anger High Vol tagel Lem RN gh Voltagel o U FENCE EARTH FENCE FEED EARTH a a id il el ET Low ass 20 JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL 5 3 Examples of Fence High Voltage Wiring Dia grams Return Feed 308088 qaad HYI g M ex e Nana Hlava 40 oe 99g bet m As CONVENTIONAL FENCE AX 1 Z14R Energiser configured for conventional fence operation E
40. omatically after 4 warning beeps A PCB fault will disarm the energiser If an error disarms the energiser the fence alarm will be activated If an error has momentarily caused the energiser to stop pulsing this can be corrected by disarming and rearming the unit Should the er ror recur return the unit for service 6 3 Jumpers www jva fence com e gt e a 3 ty ES 5 lt 76 de F electric Fencino Products 6 4 Configuring a Z14 to run in Bi Polar mode By default the Z14 is configured to run in standard mode This pro cedure explains how to modify the Z14 so that it will run in Bi Polar mode Step 1 On the back of the 7V42 Z14 PCB near the high voltage output ter minals there is a link Pictured below which needs to be cut Cut the link so that it is flush with the PCB at both points where it is soldered to prevent any arcing Step 2 Set Fence Mode programming option 15 to bipolar 214 Programming Option 15 6 5 Tamper Circuit 2146 218 Mk2 The tamper circuit serves two functions It protects service personnel from receiving a shock by disarming the energiser when the lid is re moved It also sounds alarm if the lid is removed while the energiser is running The tamper alarm can be inhibited by shorting the J3 pins together It should be noted that in order for this function to work Page 28 JVA Technolo
41. ontact with the pulsed conductors and to prevent them from becoming wedged between the electric fence and the physical barrier thereby being exposed to multiple shocks from the energiser Note 2 The separation is the perpendicular distance between the electric fence and the physical barrier 10 4 5 Prohibited mounting Electric fence conductors should not be mounted on a support used for any overhead power line 10 4 6 Operation of electric security fence The conductors of an electric fence should not be energized unless all authorized persons within or entering the secure area have been informed of its location Where there is a risk of persons being injured by a secondary cause appropriate additional safety precautions should be taken Note An example of a secondary cause is where a person may be expected to fall from a surface if contact is made with pulsed conductors www jva fence com W gt O 0 O JJ D D 3 D et W o D e et lt au D A H D gt W 7 U U U LL U U gt 5 U 7a c U j U a as pus 7 TVA Electric Fencing Products APPENDIX A GROUP SIMULTANEOUS PULSE FEATURE Group Simultaneous Pulse Feature In some Industrial Installations it may be preferable to provide the ability to link multiple Ene
42. ost terminals of the receiver Keep all connections away from any high voltage wiring specifically the Fence Feed connections coming from the left side of the ener giser Z11 Low Voltage Remote Control Reciever Connector Block Conenctor Block IN1 GATE KEYPAD SIREN STROBE 16Vac o ofo elo oje ole o GND 12V Remote Control Receiver Wiring Diagram Page 58 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL 9 3 Operation and configuration The remote controls come pre configured to work with the receiver Simply press the LOCK key to arm the energiser Press the UNLOCK key to disarm Should a remote control become lost or stolen it is possible to disas sociate the receiver with all remotes To do this press the button on the bottom right corner of the receiver unit and hold for approxi mately 10 seconds When the red light goes off the receiver has wiped all associated remote controls from its memory To associate a remote control press the button on the receiver once The light will come on momentarily Next press a button on the desired remote control The receiver light will begin flashing Press the button on the receiver and the light will stop flashing Test the remote control by pressing a button The receiver light will flash in dicating it has successfully associated with the remote control Re peat these steps for any remaining remote controls that reguire re association 10 Standard Regu
43. re electric fence Use a gate or a specially designed crossing point 4 An electric fence shall not be supplied from two different energisers or from independent fence circuits of the same energiser For any two different electric fences each supplied from a differ ent energiser independently timed the distance between the wires of the two electric fences shall be at least 2 5 m If this gap is to be closed this shall be affected by means of electrically non conductive material or an isolated metal barrier 5 Barbed wire or razor wire shall not be electrified by an ener giser 6 Any part of an electric fence which is installed along a pub lic road or pathway shall be identified at frequent intervals by warn ing plates securely fastened to the fence posts or firmly clamped to the fence wires 1 The size of the warning plates shall be at least 100 mm x 200 mm 2 The background colour of both sides of the warning plate shall be yellow The colour on the plate shall be black and shall be either Page 60 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL The symbol of figure 7 or The substance of Caution ELECTRIC FENCE 3 The inscription shall be indelible inscribed on both sides of the warning plate and have a height of at least 25 mm Figure 7 Warning plate symbol 7 energiser earth electrode shall penetrate the ground to a depth of at least 1 m 8 Connecting leads that are run inside buildings shall be
44. receiver using a rolling code algorithm to ensure security Should one or both remote controls lose synchronisation with the receiver it is a simple procedure to re associate the remotes The receiver controls the energiser by IN1 and receives power from the Keypad bus The output of the remote control receiver is a nor mally open NO contact The remote controls have a range of up to 100 metres They come fitted with a LR27A 12V battery that will provide up to 2 years service Remote Control Unit Receiver 9 1 Features Enables arm disarm of the energiser or a single zone by key chain fob remote control www jva fence com 2 ect 5 et a ro U U E U as IVA Electric Fencing Products 2 remote controls included Uses digital rolling code algorithm to uniquely and securely couple to remote controls Operates between 315 433 92MHz e 100 metres range Easily connected and configured Wire to keypad bus for power and input usually IN1 9 2 Installation The Remote control receiver unit requires 12V and OV GND from the keypad bus and its output is shown wired to INT Mount the receiver on the right hand side of the Z14 energiser Con nect 12V and OV GND from the KEYPAD terminals on the energiser to the right most terminals of the receiver as per the diagram above Connect the IN1 terminals to the left m
45. rgisers into a group When linked the individual Z Series Energisers become a Group Members of a group have simultaneous high voltage output pulses and act as is they are one energiser with multiple outputs This is designed so that no possible combination of individual outputs can be dangerous Group Mode Programming 26x A group MUST have only 1 master The other Energisers in the group are slaves For the Z14R Energisers if there is no Master a Slave will display Error 4 on the Status LED when Armed and it will not electrify the fence This is a requirement for Australian Standards For every other Z series Energisers if there is no Master each Slave will electrify the fence pulses when Armed However the simultaneous pulse feature will NOT be operating Note1 Do not interconnect the energisers via the keypad bus until after they are programmed Note2 If more than one keypad is used they will need different addresses see 8 1 4 Changing the keypad Messages and Address Note3 If Perimeter Patrol is used any keypad in the system should not have address 2 see 8 1 4 Changing the keypad Messages and Address For all Energisers that will be part of a group the procedure is as fol lows 1 Make sure the key switch is turned off and IN1 isn t shorted Page 68 JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL note that the Z14R does not have a key switch 2 Connect the battery 3 On the keypad enter Inst
46. ric Fencing Products This will return all options to the factory set defaults 7 44 Changing an Option Most of the options have possible values in the range of 0 to 9 To change any options the unit must be in Programming mode Check the option number see table below and then the table of values for that option Then press the option number followed by the required value When the programming is completed exit from Programming mode See above For example to change the power level to maximum press 019 and the keypad will beep twice to indicate that the command was suc cessful 7 5 Programming Options in Brief See Section 7 6 for more detail Power LEVEL SETS THE OUTPUT VOLTAGE LEVEL 02 Low Power SETS THE OUTPUT POWER LEVELS USED IN Low LEVEL POWER MODE 03 Fence ALARM SETS THE VOLTAGE THRESHOLD BELOW WHICH THE VOLTAGE FENCE ALARM WILL OCCUR 74 Q S m o ES 76 lt 05 Low Power SETS THE VOLTAGE THRESHOLD BELOW WHICH THE ALARM LEVEL FENCE ALARM WILL OCCUR IN Low POWER MODE MisseD PULSE SETS THE NUMBER OF PULSES WHICH MAY BE COUNT MISSED BEFORE THE ALARM IS ACTIVATED 07 BATTERY ALARM SETS THE BATTERY VOLTAGE THRESHOLD BELOW VOLTAGE WHICH THE GENERAL ALARM WILL ACTIVATE Page 30 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL SIREN ON SETS THE TIME THAT THE SIREN AND KEYPAD BEEPER WILL STAY ON AFTER AN ALARM SIREN OFF TI
47. rmed 1 Note Relay 4 is not physically fitted to PCB Relay 5 General Note Relay 5 is not physically fitted to PCB NOTE Optional extra relays can be retro fitted Contact your nearest JVA ser vice centre for details OO oo Page 44 JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL Fence Bi Polar sd o s Group Armed Note 2 Group General suorjdo Uonejjejsuj Notes 1 The siren and strobe switched 12V outputs can be used to drive external buffer relays 2 Group relay functions are only operable on the group mas ter FENCE X Fence x Alarm Zone x is Armed Pulsing AND the Fence Return Voltage has fallen below the Fence Alarm Voltage for more pulses than the Missed Pulse Count Not latched FENCE X ALARM Zone x is Off OR the Fence Return Voltage has fallen be OR OFF low the Fence Alarm Voltage for more pulses than the Missed Pulse Count Not Latched www jva fence com Page 45 JA Electric Fencing Products FENCE BI POLAR Energiser is Armed Pulsing AND the Fence Return Volt ages on either Bi polar return line has fallen below the Fence Alarm Voltage for more pulses than the Missed Pulse Count Not latched Zone x is Armed Pulsing General AC Fail OR Tamper OR Low Battery OR Gate Alarm OR In ternal Error Latched for internal errors only Siren Fence Alarm 1 OR Fence Alarm 2 OR Gate Or Tamper will time out after the Siren Time Out time T
48. s additional external lightning protection kits are recommended to further reduce light ning damage and thus reduce repair costs They are available from your local dealer 4 18 Earth Loop Monitoring The Z14 has two fence earth terminals If the earth monitoring facil ity is not reguired the Earth Out and Earth Return terminals must be joined with a wire bridge Directions on how to wire for earth loop monitoring are in Section 5 3 4 19 Noise and Interference The Z14 contains a microprocessor Extreme electrical noise can up set microprocessors The most likely cause of such noise is the high www jva fence com g M N 5 o U U m TVA Electric Fencing Products voltage output from the unit itself In the event of erratic behaviour check that the high voltage wiring is firmly connected to the termi nals and that no sparking is seen The Z14 is designed to self recover from interference Powering off both AC and battery should not be necessary 4 20 PC control A standard Windows PC may be used to control and monitor a group of Z series energisers Ask your JVA distributor for a demonstration of Perimeter Patrol software Z series energisers be connected to a PC using either a serial data adaptor such as the PAE223 or TCP IP using a PAE212 4 21 Web Server Another alternative to remotely controlling JVA Z series energisers is to use the PAE225 Webser
49. s many as fifteen energisers can be grouped Individual units in a Group have simultaneous high voltage output pulses and act as if they are one energiser with multiple out puts This is designed so that no possible combination of individual outputs can be dangerous 4 15 Remote Control Unit Optional The Remote Control Unit provides the Z14 with the ability to arm or disarm the energiser via a compact key chain fob remote control If using the remote control the siren can be used to acknowledge arm ing with 1 beep and disarm with 2 beeps see programming option 7613 Page 16 JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL The remote controls have a range of up to 100 metres They come fitted with a LR27A 12V battery that will provide up to 2 years service 4 16 Cabling High Voltage Cabling Fence Feed and Returns should be run using suitably rated cable Double insulated electric fence underground cable is suitable High Voltage Cables must never be run within the same conduit as Low Voltage Cables A minimum distance of 30mm should be kept between High Voltage and Low Voltages Cables To maintain the IPx4 rating of the enclosure and to ensure moisture does not enter the enclosure via the cable entry area a silicon sealant neutral cure must be used to seal all the cable passages 4 17 Lightning Protection Although the 214 contains internal lightning protection elements external lightning protection elements such a
50. se If the standby battery requires replacement the Power Light will flash and the Status Light will flash three times 5 10 Status Light The energiser status light indicates that the energiser requires at tention See Section 6 2 Page 24 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL 6 Technical Information www jva fence com 7 V V 2 27 NO RELAY 4 RELAY 5 SIREN STROBE 16Vac E ENERGISER CONTROL INPUT 1 DRY CONTACT NORMALLY OPEN INTERNALLY WIRED IN PARALLEL WITH THE KEY SWITCH CAN BE USED FOR A REMOTE SWITCH OR A RADIO RECEIVER THE RECEIVER MAY BE POWERED FROM THE KEYPAD 12V TERMINAL ENERGISER CONTROL INPUT 2 DRY CONTACT DEFAULT FUNCTION 15 GATE INPUT NORMALLY CLOSED WHEN THE UNIT IS ARMED AND THE GATE IS OPENED IT WILL TRIGGER THE GATE ALARM ALTERNATIVELY THIS INPUT CAN BE PRO GRAMMED TO MAKE THE ENERGISER ALTERNATE BETWEEN Low VOLTAGE AND HIGH VOLTAGE MODE SUPPLIES POWER AND DATA LINE FOR AN EXTERNAL KEYPAD THE 12 SOURCE ON THESE TERMINALS IS PROTECTED WITH 1A SELF RESETTING FUSE SwircHED 12V output Low SIDE SWITCHED 30W MAX INCLUDING SIREN A BUFFER RELAY SHOULD BE USED WHEN CONNECTING THESE OUTPUTS TO AN ALARM PANEL je Iuu 9 c 2 2 765 c de E JVA Electric Fencing Prod STROBE 2 Way SwitcHeD 12V output Low SIDE SWITCHED 30W INCLUDING STROBE BUFFER REL WHEN CONNECTING THES
51. ter programming the Keypad may be disconnected it is not required for group operation 4 As of energiser firmware 7v83 and keypad firmware 1v09 Z28 s should an empty ID between each Energiser This means if the 228 master ID 1 then the ID ofthe first slave should be 3 not 2 5 When connected to Perimeter Patrol the arm disarm function of a keypad is disabled Control of these functions is through the Perimeter Patrol interface 6 A Keypad that is connected to a Slave Energiser that is disconnected from the Group must have a KEYPAD ADDRESS set to 1 Otherwise the Energiser will not respond to commands www jva fence com W or gt O 0 O JJ D D 3 D et W o D e et lt au D A H D gt W JVA Technologies Pty Ltd electric Fencino Products IVA GROUP MODE LINKING Page 72 S92U942U 39 3 K1uno es sSJUaWAJINbay p1epuejS www jva fence com DEALER THE LOGO 15 TRADEMARK OF JVA TECHNOLOGIES PTY LTD JVA TECHNOLOGIES PTY LTD
52. them www jva fence com n qCIVAD Electric Fencing Products 4 Description 4 1 JVA Z14 Exterior Q U 7 U o Page 12 JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL 4 2 Front Panel Status Lights 4 3 Front Panel LCD Display The display on the JVA Z14 shows the voltage at the fence and return terminals The left is the return and the rightis the feed voltage Arrows at the top of the display indicate that the Energiser is in conventional mode When configured for Bi Polar operation the left side is the positive Return Voltage and the right is the negative Return Voltage The LCD also shows the programming option and current setting when in programming mode This allows the programming options settings to be checked easily 4 4 Inputs and Outputs See Section 6 4 5 Status Codes See Section 6 2 www jva fence com O D 7 e c lt 5 OVA Electric Fencing Products 4 6 Keypad Optional A keypad can be used to remotely monitor and control the 714 It is also used to set the programmable options for installer program ming options see Section 8 4 7 2 Series Models Z11 Single Zone conventional 1 5 Joule 713 Single Zone conventional 2 8 Joule Z14 Single Zone conventional or Bi Polar 4 Joule 7148 714 with relays and IR Tamper circuit 7188 Single Zone conventional or
53. ult Fence Alarm Voltage is 500 Volts O o wow 1100 VouTs Low Power Alarm Level 05x 7 6 5 Missed Pulse Count 06x This option enables the pulse count to be varied from the default 3 This is the number of bad or missing pulses that are counted before the alarm occurs NOTE The lower this option is set the more likely you are to get false alarms Page 34 JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL Missed Pulse Count 06x 7 6 6 Battery Alarm Voltage 07x This option sets the battery voltage threshold below which the alarm will activate The default Battery Alarm Voltage is 10 0 Volts and the unit will drop to low power at 9 0 Volts after beeping 4 times If the unit enters Low Power mode due to a flat battery the unit will automatically return to high voltage without warning when the mains voltage comes back on and the battery voltage rises Battery Alarm Voltage 07 www jva fence com et D 5 g o Ce 3 3 5 5 74 Q S m o US 76 74 lt TA Electric Fencing Products 7 6 7 Siren On Time 08x This option sets the duration of time that the siren will remain on after a fence alarm occurs After this time the siren will turn off for the Siren Off Time indicated in Table 7 6 8 The siren will sound again if the alarm is still present after this S
54. unding and until after the Auto Re arm time has passed Page 42 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL A setting of 0 will disable Auto Re arm If this time is set to less than the Siren Off Time the Energiser may re arm in the Off time and the number of Siren Cycles will be reduced Setting 0 was changed to immediate in version 7 77 pt p sees me nates Tm Disabled Do not auto rearm Auto Re Arm Time Values for Firmware 7 77 and above 20 et u D 5 g o 3 5 gt 5 o s www jva fence com 74 Q S m o 76 74 lt TA Electric Fencing Products TT me Auto Re Arm Time Values before Firmware 7 77 20 7 6 18 Relay Functions relays can be set to any of the available functions user assign able Relay 1 is 21x Relay 2 is 22x etc Even though the three additional relays are not fitted to the 714 Re lays 3 4 and 5 can still be programmed This means that if the relays are retro fitted to the circuit board they will function The modes are explained in the table opposite The defaults for the Z14 are Relay 1 Siren 12V switched output Relay 2 Strobe 12V switched output Relay 3 Fence 1 Note Relay 3 is not physically fitted to Relay 4 A
55. ver When suitable configured this al lows the energiser to be controlled and monitored via a web browser from any internet connected device anywhere in the world 5 Description JVA recommends installation by qualified technicians 5 1 Installation Steps 1 Read the entire manual first 2 Design and build the fence Beyond the scope of this manual Ask your distributor for help if reguired 3 Decide where the JVA Z14 is to be mounted If on an extenal wall it should be housed within a waterproof equipment box and definitely not in direct sunlight 4 Remove the JVA Z14 PCB chassis from the housing by remov ing the 2 screws Page 18 JVA Technologies Pty Ltd 10 11 12 13 14 15 16 17 18 19 JVA Z14 Z14R MANUAL Mount the housing by using 4 screws through the rear of the box Replace the PCB chassis If using a keypad remove the rear housing of the keypad and fix it to the wall Wire the low voltage cables to the PCB terminals See Sec tion 5 2 Wire the high voltage cable to the PCB terminals See Sec tion 5 2 If earth monitoring is not going to be used on the fence con nect a bridge wire from earth out to earth return Ensure that the key switch is off Fit the battery leads to the battery The Status Light should blink twice repetitively to show mains fail unless J3 is fitted Mount the 230 16V transformer and connect the 16V side to the Z14 16V input terminals AC is
56. where an Electric Security Fence is Exposed to the Public Note 2 Typical electric security fence installations are shown in Figure 9 and Figure 10 www jva fence com 7 U U U LL U U gt 5 U 7a c U U j U ce m 7a TVA Electric Fencing Products Koy A Becure Public amass araa G Hamar shar ramuirgd D Glass window pars E Skylight in mol 1 Electric security tanca Z Physical barriar Figure 10 Typical fence constructions where the electric security fence is installed in windows and skylights 10 4 4 Separation between electric fence and physical barrier Where a physical barrier is installed in compliance with 3 at least one dimension in any opening should be not greater than 130 mm and the separation between the electric fence and the physical barrier should be Page 66 O JVA Technologies Pty Ltd JVA Z14 Z14R MANUAL within the range of 100 mm to 200 mm or greater than 1 000 mm where at least one dimension in each opening in the physical barrier is not greater than 130 mm greater than 1 000 mm where any opening in the physical barrier has all dimensions greater than 50 mm less than 200 mm or greater than 1 000 mm where the physical barrier does not have any openings Note 1 These restrictions are intended to reduce the possibility of persons making inadvertent c