1. HUMLESS Safe Silent Power Power your day to day when others are power less Humless Sentinel User s Guide www humless com User s Guide Contents e Safety Instructions e Meet The Power e Charging Your Unit e Powering Your Devices e Troubleshooting e Technical Specifications page 6 page 7 page 12 page 13 page 14 page 15 About TOMICE Humless LLC gives you a seamless solution for challenging power outages Our technology is so advanced that we have no real competitors There may be other generators available but none can offer you all of the following lhumess Safe No emissions none No dangerous risks unlike fossil fuels and toxic lead acid batteries if you can t throw it away in your family s garbage can it s not good for your family Silent No more loud continuous sanity challenging generator noises Affordable The next competitor that compares in power 1000 watts continuous costs 3 times more Portable Easily carried by most weighing in at 40 Ibs 18 kg Renewable Powered and replenished by natural resources such as the sun wind and water as well as mechanical devices such as hand cranks Trademarks Humless products are a trademark of Humless LLC Other trademarks registered trademarks and product names are the property of their respective owners and are used herein for identification purposes only Notice of Copyri
2. There is no light indicator for these ports 12 V 25 A max 12V 10 A max com 11 Charging Your Unit User Instructions e Insert red key into keyhole Turn right for ON turn left for OFF Do not turn on unit first when charging with Input C Read instructions under To Charge e Push and hold green button for three seconds to check battery status e When not in use turn off all power including switches and remove key To Charge e Provide a minimum of 6 inches of clearance on all sides of the unit DO NOT cover or obstruct cooling fan vents otherwise overheating could occur Insert red key into ON OFF keyhole Turn right for ON turn left for OFF MAKE SURE VOLTAGE AND AMPERAGE OF BOTH CHARGING SOURCE AND UNIT ARE COMPATIBLE Instructions are the same for charging AC and DC options Connect AC plug into Input A 120 240 V and wall generator 1 Connect DC plug into Input B 12V 16 A or Input C 12V 10 A and also into the charging source o When using Input C make sure that you connect leads to the correct positive and negative terminals o On unit red is the positive side terminal black is the negative side terminal o WAIT TO TURN ON POWER WITH RED KEY UNTIL LEADS ARE CONNECTED When charging the charger light will be red Once fully charged the charger light will turn green When charging the charger light is red when charging or fully charged e
3. Store unit fully charged Consult with your power source manufacturer to verify proper voltage and amperage compatibility Power Your Device To Use e Provide a minimum of 6 inches of clearance on all sides of the unit DO NOT cover or obstruct cooling fan vents otherwise overheating could occur e Insert red key into ON OFF keyhole Turn right for ON turn left for ORR e MAKE SURE VOLTAGE AND AMPERAGE OF BOTH CHARGING SOURCE AND UNIT ARE COMPATIBLE e Instructions are the same for using AC USB and DC options AC Outputs e Connect AC plug into either Outlet A or Outlet B 120 V 1000 W max and turn on AC USB Outputs e If using a tablet pad or laptop connect USB plug into either Outlet C or Outlet D 2 1 A and turn on USB t e f using a cell phone or other device connect USB a into either Outlet E or Outlet F 1 A and turn on USB DC Outputs e Connect DC plug into either Outlet G 12 V 10 A max or Outlet H 12 V 25 A max depending on appliance or device e When not in use turn either or off and turn the red key to the left Consult with your appliance manufacturer to verify proper voltage and amperage compatibility lhumless Troubleshooting Your Unit 1 The Glenys Sp Indicator won t light up when I push the green button e Make sure red key is inserted into the Main Power keyhole and it is turned to the ON position e Battery is below cutoff voltage
4. al Inverter Output 120V AC Pure Sine Wave 1000W Continuous 2000W Peak Integrated AC Charger Output PWM 14 6V DC 5 0A Charging cycles CC CV Charge time 2 5 hrs Integrated Charge Controller BMS Input current 15 0A Output current 10 0A Low voltage cutoff 10 5V High voltage cutoff 15 0V Outputs 2 120V AC 1000W 2000W Continuous Peak 2 USB Outlets 5V DC 2100 mA Max 2 USB Outlets 5V DC 1000 mA Max 2 12V DC 10A Max 120W
5. al injury A caution Cautions are conditions and practices that could result in damage to the unit or other equipment Important Terms The following terms are helpful for you to know and are used in this guide TERM DEFINITION Ampere or Amp Alternating Current Direct Current Kilowatt one thousand Watts Light Emitting Diode Milliampere one thousandth of an ampere Photovoltaic Volts AC Volts DC Watts Additional Information You can find additional information about products and service at www humless com lhumess humless WARNING This Section provides important safety and operating instructions CAUTION Check with medical device manufacturer before powering any 2 life support systems or other medical devices or equipment to insure it is compatible with the power supplied by the Humless Sentinel See Technical Specifications on page 14 for the Humless Sentinel details CAUTION Check with tool and or equipment manufacturer before powering be any of their products to insure it is compatible with the power supplied by the Humless Sentinel See Technical Specifications on page 14 for the Humless Sentinel details Before using your unit read ALL instructions and information in this user s guide Although intended for indoor use it can be used outdoors if sheltered DO NOT expose the unit to rain snow or extreme environments To reduce risk of fire hazard DO NOT cover or ob
6. charge battery 2 The red light above Switch 1 on the 120V AC Outlet lights up and there is no power from outlet e Battery is low Check charge state and recharge battery e Load is too high Turn down appliance or make sure appliance power ratings are less than 1000W e Inverter overheating Create space around vents and allow inverter fan to cool the inverter 3 The Gheigjo SEM Indicator lights give different readings at different times without charging or using any stored power Geng SEM Indicator provides approximate charge status only e Battery pack voltage will settle after charging 4 DC Input charging light will not light up even though my charging source is plugged in e Make sure red key is inserted into the Main Power keyhole and it is turned to the ON position e Input polarity is reversed Reverse input polarity e Charging source voltage is less than your battery voltage try a different charging source 5 12V DC Outlet won t work e Make sure red key is inserted into the Main Power Switch and it is turned to the ON position e Battery is below cutoff voltage charge battery 14 Technical Specifications Product Specifications Dimensions L x W x H 18 x 10 x 12 Weight 40 Ibs Internal Lithium Battery Pack Voltage 12 8V Capacity 50Ah 600Wh Cycle life 2 000 cycles Minimum charge time lt 2 5 hrs Charge retention gt 12 months Intern
7. e to become familiar with the Safety Instructions on page 6 of this guide before operation If you still have any questions please contact our support team See Contact Information on page 4 Let s Get Started You should have received the following items in your Humless Sentinel kit Unit with carrying harness Shoulder Strap Zippered stow pack 1 AC wall outlet charging cord Red Key 2 USB Universal cell phone charger USB LED light Red Key for Main Power NOOR WD Things to remember e When not in use turn off all power including switches and remove key e Store unit fully charged com Interface Panel 4 j 2 A Z 6 Z 6 s lt I 0 a e Insert red key into main power keyhole Turn right for ON turn left for OFF Before charging Input C turn red key to OFF Read instructions under To Charge e Push and hold green Charge Status button for three seconds to check battery status Provide a minimum of 6 inches of clearance on all sides of the unit DO NOT cover or obstruct cooling fan vents otherwise overheating could occur e When not in use turn off all power including switches and remove key TO CHARGE Instructions are the same for charging AC and DC options fa Connect AC plug into Input A 120 240 V and wall or generator Connect DC plug into Input B 12V 16 A or Input C 12V 10 A and also into the charging source When usin
8. g Input C make sure that you connect leads to the correct positive and negative terminals 2 On unit red is the positive side terminal black is the negative side terminal Input B 12 V 16 A max When charging the charger light will be red Once fully charged the charger light will turn green When charging the charger light is red when charging or fully charged Store unit fully charged TO USE Instructions are the same for using AC USB and DC options Connect AC plug into either Outlet A or Outlet B 120 V 1000 W max and turn on AC Switch 1 If using a tablet pad or laptop connect USB plug into either Outlet E or Outlet F 2 1 A and turn on USB Switch 2 if using a cell phone or other device connect USB plug into either Outlet C or Outlet D 1 A and turn on USB Sto 2 Connect DC plug into either Outlet G 12V 10 A max or Input C Outlet H 12 V 25 A max depending on appliance or device 12 V10 A max POWER OUTPUT 12V 10 A max Outlet A 120 V 1000 W max Outlet B 120 V 1000 W max 1A Cell Phones 2 1 A Tablets Pads 12V 25 A max Charge Status Indicator a Press and hold green button three seconds to obtain an accurate reading com FULL CHARGE STATUS is indicated when all four LEDs are illuminated and AC and DC charge lights in Charging Inputs section show green AC Charging Input A N warnine Electrical Shock can occur if AC po
9. ght Humless User s Guide March 2012 Humless LLC All rights reserved Exclusion for Documentation UNLESS SPECIFICALLY AGREED TO IN WRITING HUMLESS LLC HUMLESS A MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OF OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION B ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES DAMAGES COSTS OR EXPENSES WHETHER SPECIAL DIRECT INDIRECT CONSEQUENTIAL OR COINCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK C REMINDS YOU THAT IF THIS MANUAL IS PRESENTED IN ANY LANGUAGE OTHER THAN ENGLISH ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION THE ACCURACY CANNOT BE GUARANTEED APPROVED HUMLESS CONTENT IS CONTAINED WITHIN THE ENGLISH LANGUAGE VERSION WHICH IS POSTED AT WWW HUMLESS COM Date and Revision March 2012 Revision A Product Number HSS50 120W Contact Information Telephone 1 800 313 4709 Technical Support helo humless com Sales and Customer Service sales humless com All other issues info humless com Website http Avww humless com Mailing address Humless LLC 4626 N 300 W Suite 350 Provo Utah 84604 U S A Please feel free to contact us at any time Symbols and erms The following symbols are used in this guide N Warnings are conditions and practices that could result in person
10. struct fan vents Provide a minimum of 6 inches of clearance on all sides of the unit otherwise overheating could occur You may connect as many as 3 DC power sources and 1 AC power source simultaneously To reduce risk of electrical shock disconnect all sources of AC and DC from the unit before attempting any cleaning or maintenance or before working on any circuits connected SWITCHING OFF ALL POWER DISCHARGE PORTS WILL NOT ELIMINATE RISK TURN OFF MAIN POWER AND REMOVE RED KEY Inspect all power cords before attempting to charge your unit and connecting devices to discharge ports If cords are frayed damaged or questionable DO NOT connect the device to your unit Doing so increases the risk of fire and electrical shock Use common sense DO NOT use if your unit has been dropped or damaged in any way If damaged see Contact Information on page 2 DO NOT attempt to disassemble the unit There is a high risk of unit damage as well as personal injury There are NO serviceable parts Repairs should ONLY be done by a qualified Humless repair technician Meet the Power Thank you for your purchase The pure sine wave AC inverter output makes your unit compatible for use with many of today s high tech electronic devices It also allows appliance motors to operate more efficiently and at cooler temperatures In order to get the most from your unit be sure to carefully read this user s guide It is important to take some tim
11. wer cord is damaged or frayed Never use a damaged or frayed AC power cord Replace with a new cord before proceeding with AC charging lt AC INPUT light is red while charging AC INPUT light is green when fully charged Input A 120 240 V 10 DC Charging Input B and Input C J N warning Electrical Shock can occur if DC power cord is damaged or frayed Never use a damaged or frayed DC power cord Replace with a new cord before proceeding with DC charging DC INPUT DC Charge light is red while charging DC Charge light is green when fully charged DC INPUT DC Charge light is red while charging DC Charge light is green when fully charged AC Usage Outlets J N warning Electrical Shock can occur if AC power cord is damaged or frayed Never use a damaged or frayed AC power cord Replace with a new cord before proceeding with AC charging Bue meek Outlot B A green light indicates power is present normal operation iog l m A red light indicates fault low Switchi 420 V 1000 W max 120v1000wmax PAttery or overload 4 USB Outlets Outlet A green light indicates power is m present normal operation Outlet D Outlet E Outlet F Switch 2 Check with your device manufacturer for proper power requirements and compatibility DC Outlets Outlet G Outlet H Check with your device manufacturer for proper power requirements and compatibility Kai Oy Ip K gt