TROUBLESHOOTING LIVESTOCK AND POULTRY VENTILATION

image

Contents

1. TROUBLESHOOTING LIVESTOCK AND POULTRY VENTILATION PROBLEMS EU IKSTRUGTIUNS NEW 87 11 H E Huffman This environment should provide comfort for the animals not just for the operator The behavior and productivity of animals The ventilation system is one of the most important yet least are the best clues to ventilation performance if they are understood components in a livestock or poultry barn Its main comfortable they will look and act comfortable For example functions are to remove respired moisture excess heat gases huddling and panting are common animal reactions to odors and dust while maintaining a comfortable draft free temperature extremes too cold or too hot respectively environment The Canada Plan Service prepares detailed plans showing how to construct modern farm buildings livestock housing systems storages and equipment for Canadian Agriculture PL AN SERVICE To obtain another copy of this leaflet contact your local provincial agricultural engineer or extensionadvisor The troubleshooting tables in this leaflet describe some of the problems that occur in livestock and poultry buildings list the possible causes and suggest remedies One must also appreciate that ventilation problems tend to be interrelated one problem often causes another For example consider the situation where a crossflow air inlet is open too wide The main problem will be poor air distribution within the barn but several
2. Install corrugated metal ceiling in direction of airflow during construction Preheat incoming air in hallway Move soffit intake farther out from wall towards fascia board Restrict close down external air intake for winter period using a hinged door or sliding panel Draw air from attic during winter if continuous ventilation is certain Seal excess cracks and holes Cover summer exhaust fans Consult the manufacturer s literature or contact representative for assistance TABLE 2 TROUBLESHOOTING SUMMER VENTILATION PROBLEMS Problem Air too hot throughout building compared to outside temperature Building air too hot in specific areas Building air hotter than desirable for the animals birds Excessive daily building temperature changes and or draft problems Possible causes Insufficient air movement fan s not operating fan blades not set properly in orifice insufficient fan capacity fan hoods too small or obstructed opening to grouped fans too small for total air flow Restricted airflow from outside intake to inlets air intake not large enough warmed attic air drawn in because of insufficient air intake area Excess attic heat load to building insufficient attic insulation and or ventilation dark nonreflective roof surface Excess animal density Air inlets open too far causing short circuiting to exhaust fans or concentrated air inlet Lack of fresh air Ambi
3. VALUATION FORM FARMER TEL NO amp AREA CODE ADDRESS _ 0 LOT ___ CONC TWP 00000000 COUNTY On the reverse draw a sketch of the barn or room Show length width and layout of room s location of doors windows air inlet fans identify fans by number orientation of barn show direction of north Use of a scale of 1 square 1 2 or more units ft or m for small medium or large rooms respec tively Ceiling height Livestock Type _____ ____Number ____________ AvWt List of existing fans No of Fan No Size Speeds Manufacturer Air Inlet description intake source of fresh air control mechanism Other information that may affect the ventilation
4. ent temperature too hot for animal or bird comfort Birds animals showing signs of heat stress panting lethargy poor appetite Thermostatic control settings too low Remedies Replace defective controls or motor Adjust fan on shaft for one third protrusion Add high capacity fans or open building completely by opening doors and windows Increase fan hood size to at least two times fan area Increase wall opening or move a fan from group to other wall Increase air intake area on outside of building Increase air intake area on outside of building and ensure vertical blocking is placed between trusses Reinsulate attic and ensure adequate eave inlet and ridge or gable opening areas Consider either painting the roof white to reflect the sunlight or installing a new roof that has a solar reflective surface Reduce animal bird density during summer if practical Reduce air inlet opening to cause jetting in all areas close doors Add continuous air inlet or air recirculation system Install intermittent spray cooling system rather than increase fan capacity above normal rates thus permitting evaporative cooling from body surfaces Use evaporative air cooling systems if summer relative humidity is usually low Do not insulate under concrete floors where mature animals are being housed Raise thermostat temperature settings to reflect a higher acceptable room temperature during warm weather VENTILATION E
5. in building This might take the form of recirculation equipment In older buildings seal oversized cracks or holes wherever air is good TABLE 1 TROUBLESHOOTING WINTER VENTILATION PROBLEMS CONT D Problem Condensation on walls or ceiling of building Large building temperature fluctuations e g 5C every 10 minutes or so Building too cold air quality good Possible causes Insufficient insulation Insufficient heat to provide moisture control at desired building temperature Nearly saturated air migrating to cooler building area Excess ventilation exhaust fan capacity steps too large too much fan capacity per thermostat faulty insensitive thermostat thermostatic control not located to sense average room temperature Oversized heater Excess ventilation thermostatic control set too low exhaust rates too high Lack of insulation or heat over ventilation is used to control condensation insufficient heat Remedies Add or replace insulation Lower building temperature and humidity by increasing exhaust rate if animals can tolerate cooler conditions Add supplemental heat particularly for young animals and poultry Relocate some mature animals to cooler area to raise the temperature Recirculate inside air to eliminate the temperature differential Isolate the problem area except when in use e g cow holding area at milking parlor Install lower capacity fans Install addit
6. ional thermostatic control or switch off one fan during very cold weather Clean or replace thermostatic control Move thermostatic control away from draft or heat source affecting sensor Reduce firing rate or replace with smaller heater Readjust clean or replace thermostatic controls Install one or more lower capacity exhaust fans Switch off one of two fans connected to one thermostatic control Calibrate thermostatic control with an accurate thermometer Step the thermostat settings to prevent over ventilation in cold weather Insulate building to permit higher relative humidity without condensation Increase stocking density Consider conventional supplemental heating heat exchangers solar walls etc TABLE 1 TROUBLESHOOTING WINTER VENTILATION PROBLEMS CONT D Drafts Problem Possible causes Air inlet opening too wide causing cold air to fall Obstruction on ceiling causing cold air to fall greatest effect in low airflow applications e g furrowing and calf units Soffit air intake not hooded or protected from wind Leaky older building poor fitting doors and windows Mechanical air recirculation distribution systems that are oversized misplaced or misdirected Remedies Reduce inlet opening to create air jetting and mixing above animals birds Remove obstruction or reduce effect provide at least 1 m of smooth ceiling surface in front of air inlet Suspend conduit farther from ceiling
7. other related problems will develop Colder incoming air will fall to the floor very quickly creating drafts Temperatures may not be uniform throughout the barn and the air will become damp because the respired moisture is not being adequately mixed and exhausted through the fans By reducing the size of the air inlet the incoming air is jetted into the barn creating better mixing and a good air circulation pattern Not only has the air distribution problem been solved but there is no longer a floor draft or uneven temperatures and more water vapor is being carried to the exhaust fan by the better mixed air Sometimes such interrelationships can make the analysis of ventilation problems more difficult Often you must make several changes to completely solve a problem WHO CAN HELP Ventilation is not a simple exact science Obviously problem identification and problem solving became easier with time and experience If you have difficulty in solving a problem contact someone with ventilation expertise First try the equipment supplier who should be able to correct any equipment malfunctions Often the equipment is installed and or wired incorrectly contact your building contractor and or electrician for these types of problems Agricultural extension engineers and power company personnel can also help This leaflet also contains a Ventilation Evaluation Form Use it to record the details of the barn and its ventilation problem Thi
8. s information will be essential for evaluating a particular case especially if the ventilation consultant is not able to make an on site inspection You can cut this form from the leaflet and mail it to your ventilation consultant ADDITIONAL INFORMATION can be found in other Canada Plan Service plans in the 9700 series and in Agriculture Canada Publication 1799 E Good Energy Management in Farm Livestock Housing TABLE 1 TROUBLESHOOTING WINTER VENTILATION PROBLEMS Problem Possible causes Bad air throughout building ventilation Insufficient or intermittent Remedies Check fan louvres for free movement Install smaller step 1 exhaust fans to allow continuous minimum ventilation If animals can tolerate cold reduce thermostat setpoints to increase ventilation rate Bad air in localized areas within building Thermostatic controls of continuous fans not located set or wired properly Insufficient heat to force continuous ventilation while maintaining building temperature Exhaust fans not protected from outside wind pressure Fresh air not well distributed within building space Check control location for drafts or dead air pocket Check calibration setting using a thermometer Check that two speed fans are switching to low speed not high when temperature falls Add supplemental heat to maintain temperature Install proper fan hoods to maintain an output in spite of headwinds Adjust or add air inlet

Download Pdf Manuals

image

Related Search

Related Contents

金属材料引張試験機マニュアル(PDF 294kB)  Air Tempo manuel du propriétaire  TechniSat DigiPal 2 User's Manual  USER`S MANUAL  室外関連部品  

Copyright © All rights reserved.
Failed to retrieve file