Home

OPERATING INSTRUCTIONS

image

Contents

1. 7 0 bar as required check the tank pressure of the compressor amp adjust the start stop limits check the air recommended use fewer tools simultaneously do not exceed the capacity of the compressor or of the delivery system drain water from the compressor delivery system a 3 8 hose is SECOND CHECK FOR AIR LEAKS At rest this tool should not have any air leaks Before attempting to repair the tool and replace parts check the following Check all seals in head valve and cylinder assemblies replace if necessary Check the top edge of main cylinder for burrs or dents Clean amp lubricate the head and valve assemblies re assemble the head assembly carefully Check the interior of the head for scratches TOOL DOES NOT DRIVE FASTENERS Check for fasteners in the feeder channel Check that the proper type of fasteners is used 16GA amp 18GA nails are not interchangeable Make sure the feeder clip is engaged behind the fasteners Check the front end of the feeder channel for burrs or damages Check the safety mechanism Check if the driver is stuck in down position see note below Check for obstruction in the fastener ejection area P250 amp Q550 PRIMPACT tools only Remove the head assembly Make sure the cylinder is fully screwed onto it Re insert the head assembly in place and insure that it is fully screwed in place using moderate effort Lock in place with the head lock Check regularly that the head is always
2. MERCHANTABILITY FITNESS OR OTHERWISE EXCEPT AS STATED ABOVE and Primatech s liability AS STATED ABOVE AND AS ASSUMED ABOVE is in lieu of all other warranties arising out of or in connection with the use and performance of the tool except to the extent otherwise provided for by applicable law PRIMATECH SHALL IN NO EVENT BE LIABLE FOR ANY DIRECT INDIRECT OR CONSEQUENTIAL DAMAGES WHICH MAY ARISE FROM LOSS OF ANTICIPATED PROFITS OR PRODUCTION SPOILAGE OF MATERIALS INCREASED COST OF OPERATION OR OTHERWISE Any liability if any connected with the use of the tool shall terminate upon the expiration of the warranty period specified above
3. efficiency TO PREVENT ACCIDENTAL DAMAGE TO THE FINISHED SURFACE OF THE INSTALLED FLOOR REST THE TOOL ONTO THE SUBFLOORING WHEN CONNECTING AIR LOADING TOOL OR PERFORMING ANY MAINTENANCE TO THE TOOL LOADING THE TOOL For P245 nailer e Insert a row of flooring nails inside the magazine e Pull back the pusher until it engages behind the nails e To remove nails from the magazine simply squeeze the pusher with your thumb and finger and allow the spring to recoil slowly For the P245 stapler e Pull the pusher completely in the rear position and apply downward pressure to engage it into the locking position e Insert strips of staples through the opening on top of magazine Do not overfeed e While pulling back and applying upward pressure to release the pusher from its locking position Then move the pusher slowly until it engages behind the staples For maximum performance always use PRIMATECH nails or staples Always operate the tool with fasteners in magazine Damage may occur if the tool is operated without fasteners USE ONLY THE TYPE OF FASTENERS IDENTIFIED ON THE MAGAZINE THE USE OF ANY OTHER TYPE OF FASTENERS WILL DAMAGE THE TOOL OPERATION Unload tool and rest it onto the subflooring Connect the hose and cycle tool once or twice without fasteners After loading the tool the PNEUMATIC TOOL model P245 is ready for use Use only the 2 5 lbs 1 1 kg hammer supplied with the tool The use of other type o
4. such as Primatech P 090 A few drops of oil weekly in the air inlet is sufficient Other Pi types of lubricant may degrade the seals Check periodically to make sure that all screws are tight If screws are loosening up the use of a medium strength adhesive sealant is recommended CLEANING THE VALVE If the tool becomes sluggish or does not set the fastener correctly it may indicate excessive dirt dust other particles or even water in the tool The first step in troubleshooting is to clean up the head assembly Disassemble the head assembly as described in previous section Perform a visual inspection of the valve assembly Ensure that the actuator is sliding easily Clean and lubricate lightly Do not attempt to take apart the actuator assembly Clean the inside wall of the head and lubricate lightly with a non detergent oil Insert the valve assembly into the head and ensure that it is sliding easily Ensure the piston assembly is sliding easily into the cylinder It should offer some resistance but if it moves too easily it may be required to replace the piston wear ring Head with cap Valve assembly Cylinder Piston assembly Bumper Seal bushing ASSEMBLING THE VALVE This section describes how to re assemble the tool after maintenance The following procedure assumes that the gate foot assembly along with the resting block are already installed 1 Insert the seal bushing in the lowe
5. d and should be worn by the operator and others in working area Accidental ejection of fasteners or wood debris could cause severe eye injury In some environments ear protection might be required as working conditions may include exposure to high noise levels which lead to hearing damage Wearing safety boots and a safety hat is also highly recommended NOTE All the personal protection equipment must meet national standards CONNECTION amp AIR SUPPLY SYSTEM To ensure maximum performance and efficiency and also a minimum of care the PRIMATECH pneumatic tool requires clean dry air It is necessary to use a filter and a pressure regulator This tool needs a detachable male coupler with 3 8 NPT male threads The use of a 3 8 1 cm diameter air supply hose is recommended A smaller hose or a hose longer than 50 15 m could cause a pressure drop when the tool is activated repeatedly AN A Ax ALWAYS USE A FREE FLOW CONNECTION FOR THE COMPRESSED AIR SUPPLY TO PREVENT THAT THE TOOL STAYS CHARGED AFTER DISCONNECTING THE AIR SUPPLY HOSE UNLOAD TOOL BEFORE CONNECTING AIR TO PREVENT ACCIDENTAL DISCHARGE AFTER MOVING TOOL TO A DIFFERENT WORK AREA OR AFTER ANY MAINTENANCE TO THE TOOL ALWAYS ENSURE PROPER OPERATION BY ACTUATING TOOL SEVERAL TIMES WITHOUT FASTENERS OVER THE SUBFLOORING Dirt dust and other particles in the air supply can cause sluggish operation or premature wear of many components of the t
6. ech ca web http support primatech ca SAFETY MEASURES These important guidelines should always be followed to work safely with the PRIMATECH pneumatic tool model P245 Read these instructions thoroughly before using this tool and keep it handy for reference if necessary Always keep hands feet or other body parts away from the fastener ejection area Never aim the tool in any direction other than the working area Always carry or manipulate the tool by its handle while the air supply hose is connected Never hit the head cap of the actuator if the plastic base is not sitting perfectly on the working surface Never leave the tool laying down on its side while the air supply hose is connected the tool should always be left on the floor standing on its plastic base Always disconnect the air supply hose when the tool is not in use or when moving to another work area Never service or repair the tool clear obstructions or make adjustments while the air supply hose is connected Only compressed air should be used to power this tool do not exceed 110 psi 7 6 bar Never use oxygen or any other compressed gas as a power source for this tool Explosion may occur e Always wear OSHA required Z 87 safety glasses with side shields e Always wear proper ear and foot protection while the air supply hose is connected e Always remove fasteners from the magazine before servicing tool Eye protection is recommende
7. eriod shown below after the date of purchase by the original user as evidenced by a valid purchase invoice ONE YEAR LIMITED WARRANTY will apply to all parts except those subjected to normal wear SEVEN YEAR EXTENDED LIMITED WARRANTY covers tool casing WARRANTY STATEMENT Primatech s sole liability hereunder will be to replace any part or accessory which proves to be defective within the specific time period Any replacement part or accessories provided in accordance with this warranty will carry a warranty for the remainder of the period of warranty applicable to the part it replaces When repair or replacement of part or tool is required the complete tool or part s must be returned to Primatech or at such authorized warranty service point of Primatech transportation prepaid with a copy of proof of purchase evidencing that the part or tool is within the warranty period Serial must be intact and legible for warranty to apply This warranty is void as to any tool which has been subjected to misuse abuse accidental or intentional damage used with fasteners not meeting Primatech specifications size or quality improperly maintained repaired with other than genuine Primatech replacement parts damaged in transit or handling or which in Primatech s sole opinion has been altered modified or repaired in a way that affects or detracts from the performance of the tool PRIMATECH MAKES NO WARRANTY EXPRESSED OR IMPLIED RELATING TO
8. f hammers may affect performance The rubber face of the hammer can be used with care to help position the boards With the flooring firmly in place position the tool onto the flooring and apply downward pressure to ensure proper seating of the fastener Strike the head cap Q 001 with the hammer to activate the tool Use only the RUBBER FACE of the hammer to activate the tool Using the steel end will damage the tool and void the warranty If wood is slightly twisted hitting the tool with more force will assist in pulling the board up snugly NEVER strike the head cap when the tool is not sitting on the working surface Be it raw factory finished or engineered hardwood is a natural material subject to various factors such as humidity subflooring installation procedure type of tools fasteners etc Installer should always ensure optimal surface preparation comply with all manufacturers recommendations and conduct a pre installation test prior to beginning any installation A BEFORE STARTING AN INSTALLATION FASTEN DOWN FEW BOARDS TO ASCERTAIN THAT YOU ARE USING THE RIGHT FASTENER AND THAT THE TOOL IS PROPERLY ADJUSTED MAINTENANCE amp REPAIR Most adjustments to the tool can be made with the 3 16 Allen wrench supplied with the tool Disassembly of the tool must be done in a clean environment Some parts can be easily damaged if disassembled with improper tools or by inadequate methods Maintenance should only be perfo
9. fully screwed FASTENERS ARE NOT SET COMPLETELY First check air supply see first note Clean and lubricate tool particularly the head assembly Increase air pressure when working with harder woods do not exceed 110 psi 7 6 bar Check the driving blade for broken end Check piston wear ring replace if piston is sliding too easily Check seal bushing Check the adjustment of the base and ensure the tool is well seated on the floor while ejecting TOOL DOES NOT ACTIVATE Check air supply Inspect the head assembly and check all seals reassemble carefully DRIVING BLADE DOES NOT RETURN Check for jammed fastener or obstruction Check gate foot and end of feeder channel for damages or burrs Check the driving blade Inspect the head assembly and check all seals clean amp lubricate Check band valve on cylinder Check that the bumper and seal bushing are in place severe damages will occur if missing BROKEN OR WORN DRIVING BLADE Replace the driving blade failure to follow the instructions carefully will result in repeated breakage of the driving blade OTHER PROBLEMS Contact technical support by phone 1 800 363 1962 1 418 522 7744 by email support primatech ca on line http support primatech ca M rimatech TOOL WARRANTY AND LIMITATIONS Primatech warrants that newly purchased fastening tools parts and accessories will be free from defects in material and workmanship excluding wear parts for the p
10. hh rimatech P245 PNEUMATIC FLOORING TOOL OPERATING INSTRUCTIONS Read these instructions thoroughly before using this tool and keep it handy for reference Printed in Canada v140 08 15 PRIMATECH PNEUMATIC TOOL P245 The pneumatic flooring tool P245 is a professional precision tool specially developed for the installation standard 3 4 solid hardwood flooring It has been designed for easy maintenance where major components can be easily accessed Weighting less than 10 pounds 4 5 kg this ergonomically designed tool makes the installation of hardwood floor very easy allowing the operator to set and fasten the boards in the standing position It is offered in 3 different configurations e nailer P245L takes standard L type 16GA nails in lengths of 1 38 mm 1 44 mm or 2 50 mm e nailer P245T takes T type 16GA nails in lengths of 11 38 mm or 2 50 mm e stapler P245S takes 12 crown 152GA staples in lengths of 1 38 mm 1 44 mm or 2 50 mm For best results only PRIMATECH fasteners should be used Read these instructions carefully before operating the tool It is important to understand warnings cautions and the safety measures to ensure safe use of the tool Additional information is available directly from the manufac turer hh rimatech 1135 J r mie Fortin Qu bec QC Canada GiJ 1R8 Phone 1 800 363 1962 or 1 418 522 7744 Fax 1 418 522 7466 email support primat
11. ool Drain water from the compressor tank regularly The compressor start stop limits should be set to deliver an air pressure of at least 100 psi 7 bar at all times Consult the compressor manual or dealer for instructions on how to make this adjustment At 80 psi 5 5 bar and 40 hits per minute this tool consumes approximately 1 9 cu ft 50 R of air per minute at 70EF 21EC Higher air pressure will increase the consumption of compressed air This tool is designed to be operated with a compressed air pressure of 80 to 100 psi 5 5 7 0 bar Air pressure of 90 psi 6 2 bar is adequate for most situations although occasionally a higher pressure could be necessary For example to use the tool with different species of harder wood Always use the tool at minimum operating pressure in order to avoid unnecessary high noise level In these more difficult cases the compressed air pressure can be increased up to 110 psi 7 0 bar It is very important not to exceed this maximum pressure to prevent leaks premature wear or damage to the tool Check the compressed air supply hose before connecting to ensure that it is free from dirt or particles that can alter the performance of the tool Pay special attention to any air leaks Do not use a compressed air pressure higher than 110 psi 7 6 bar Higher pressure can cause premature wear or damage to certain components After assembly check all the connections to prevent leaks and to have maximum
12. r section of main body and engage it onto the upper portion of the gate foot assembly A flat screwdriver can help locate it correctly Use the wooden handle of the hammer to tap the seal bushing completely in place Note select the appropriate replacement part 2 3 4 5 6 use P 525B for the L or T nailers use P 525C for staplers With the tool in the upright position push the bumper in place indexed onto the seal bushing Insert the piston assembly into the tool and engage the driving blade thru the opening of the seal bushing and engage itdown completely into gate foot assembly guiding channel Insert the cylinder into the tool engaging the piston assembly into it Check that the band valve on the cylinder is properly installed Pull up the actuator and insert valve assembly into the top opening of the cylinder Push down the valve to sit onto it Screw the head on body AFTER REASSEMBLY ALWAYS ACTUATE THE TOOL FEW TIMES WITHOUT FASTENERS AGAINST A PIECE OF WOOD TO INSURE PROPER OPERATION Head with cap Valve assembly Cylinder Piston assembly Bumper Seal bushing REPLACING THE DRIVING BLADE The driving blade is sold separately or supplied as a complete subassembly with the piston P 622A Pull out the piston assembly as described in the previous sections Remove any debris and assess condition of cylinder If marked or gouged use fine sand paper to smooth o
13. rmed by trained personnel Use only genuine PRIMATECH replacement parts TO PREVENT INJURY ALWAYS DISCONNECT THE AIR SUPPLY HOSE WHEN SERVICING OR DISASSEMBLING THE TOOL When servicing the tool do not twist or force any parts Damage may result from such abuse If parts do not come loose easily contact your PRIMATECH distributor for more information When opening the tool for maintenance always clean all components of dirt grit or particles Inspect the tool carefully for broken parts or excessive wear and replace if necessary When ordering parts be sure to specify the right part number as well as the tool serial number AFTER ANY MAINTENANCE TO THE TOOL REMOVE ALL FASTENERS BEFORE CONNECTING AIR AND ACTUATE THE TOOL REPEATEDLY OVER A PIECE OF WOOD OR SUBFLOORING TO INSURE PROPER OPERATION DISASSEMBLING THE TOOL All pneumatic components can be easily accessed with the use of an Allen key This section describes how to disassemble the tool to access its internal components 1 Remove the 4 screw and take off the head 2 Pull out the valve assembly Inspect wear ring amp lubricate Do not attempt to disassemble the valve assembly 3 Pull out the cylinder 4 Pull out the piston assembly Inspect wear ring and lubricate It is usually not necessary to pull out the bumper and the seal bushing for maintenance PREVENTIVE MAINTENANCE This tool requires minimal lubrication Use only ON detergent free oil
14. ut walls The piston must be allowed to move without restriction P 423 P 237 Lock the piston in a vise using a rag to prevent scoring Always use the top and bottom faces to secure the piston in place Remove the broken driver using a 1 2 wrench Put one drop of medium strength adhesive sealant onto the threads of the piston Insert the P 622C lock washer and screw the new driving blade onto the piston Tighten very hard 140 IbAn minimum Make sure that the lock washer is completely flattened Note select the appropriate driving blade use P 423 driving blade for the L or T nailers use P 237 driving blade for staplers Remove the bumper inspect amp remove debris Reassemble tool following instructions in previous section TROUBLESHOOTING PRIMPACT PNEUMATIC NAILERS STAPLERS HEAD ASSEMBLY LOOSENS UP DURING OPERATION This technical note will help to diagnose common problems and will give suggestions to solve them Consult our on line Technical Support site at support primatech ca for updated documents and more tips TO PREVENT INJURY ALWAYS DISCONNECT THE AIR SUPPLY HOSE WHEN ADJUSTING SERVICING OR DISASSEMBLING THE TOOL FIRST CHECK THE COMPRESSED AIR SUPPLY Many of problems come from a faulty or inadequate compressed air supply system Before attempting to repair the tool the following points should be checked check the pressure at the output of the compressor adjust to 80 100 psi 5 5

Download Pdf Manuals