TCWS.54CE3 INSTALLATION AND OPERATING INSTRUCTIONS

image

Contents

1. Lighting Instructions ws FOR YOUR SAFETY READ BEFORE LIGHTING Ww Do nottouch any electric switch do not use any phone in your WARNING If you do not follow these instructions building exactly a fire or explosion may result causing Immediately call your gas supplier from neighbour s phone property damage personal injury or loss of life Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department A This appliance is equipped with an ignition device which auto Use only your hand to push in or turn the gas control knob Never matically lights the pilot Do not try to light the pilot by hand use tools If the knob will not push in or turn by hand don t try B BEFORE LIGHTING smell all around the appliance area for gas to repair it call a qualified service technician Force or at Be sure to smell next to the floor because some gas is heavier tempted repair may result in a fire or explosion than air and will settle on the floor D Do not use this appliance if any part has been under water WHAT TO DO IF YOU SMELL GAS Immediately call a qualified service technician to inspect the Do not try to light any appliance appliance 8 to replace any part of the control system amp any gas control which has been under water RS cc STOP Read the safety information above on this label 6 Push the On Off switch to turn the fireplace on Set wall switch hand held r
2. Fig 46 This fireplace is supplied with a wall control and hand held remote control Please note only genuine Town 8 Country Fireplace wall controls and hand held remote controls can be used on this fireplace TONS s 1 Initial set up of the hand held remote is FIREPLACES required A learn button is located on the lower left hand side of the wall switch This should be depressed with a paperclip pencil or other thin object Fig 46 2 Once this has been pressed press the center button on the hand held remote Fig 47 The fireplace will then turn on 3 Turn off the fireplace by pressing the center button again The handset is now synchronized with the fireplace Initial Settings STANDING Time and temperature LEARN BUTTON PILOT BUTTON 1 Press and hold the 1 and A2 buttons ON OFF BUTTON at the same time until the temperature symbol flashes Fig 48 2 Use the up and down arrows to set pre ferred temperature units F or C 3 Press OK and the hour value will start to flash FLASHES 4 Use the up and down arrows to set the hour value 5 Press OK and the minute value will flash 6 Use the up and down arrows to set the minute value 7 Press OK and the day value will flash 8 Use the up and down arrows to set the day value 9 Press OK to end initial set up Y TOWN a COUNTRY TCWS 54CE3 2 0313 44 28 Chil
3. determine the vent height determine the vent horizontal length from the chart determine the restrictor position Refer to the chart in Fig 39 for the correct position of restrictor for the vent configuration of your installation Restrictor positions are based upon lab tests The ideal position may vary slightly with installation Restrictor position is too closed if the flame has the following characteristics e Flame is excessively tall and lifting Flame lacks movement e Flame soots Restrictor position is too open if the flame has the following characteristics e Flame height is low Flame has excessive movement To adjust the restrictor Loosen the screw holding the restrictor Move the restrictor to its intended opening e Re tighten the screw CAUTION The vent restrictor must be fully open when using the TCVT PVB2 or TCVT FMPV power OPENING vent kit to vent this fireplace VENT RESTRICTOR Y TOWN a COUNTRY TCWS 54CE3 2 0313 44 LUXURY FIREPLACES Firebox Panels Installation 1 Remove the 2 inner screws from the upper heat shield Fig 41 2 Slip the top porcelain panel into the lip at the front of the firebox and tip the panel up to align with the screw holes Secure with the previously removed screws Fig 42 3 Insert the back panel into the firebox by tilting the panel and rest the panel on the seat tabs at the back of the firebox Fig 43 NOTE
4. E 27 Maestro Control System 28 Remote Control Initial Sub 28 Maestro Control System Operation 29 O A 32 TCWS 54CE3 Replacement Parts 33 Replacement Parts Maestro Control 34 Wining Dias 35 Roof Termination Kit rancia 36 vent Pipe DIMENSIONS sesionar 37 Vent Offset Ra do 38 Quick Panel Removal for Valve Service 39 Safety 43 TCWS 54CE3 2 0313 44 FOR YOUR SAFETY Do not install or operate your Town amp Country fireplace without first reading and understanding this manual Any installation or operational deviation from the following instructions voids the Town amp Country Fireplaces Warranty and may prove hazardous This appliance and its individual shut off valve must be disconnected from gas supply pip ing system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Note When lit for the first time the appliance will emit a slight odo
5. P1 weekday ON time Fig 54 2 Use the up and down buttons to change the time to the desired ON time 3 Bypressing the OK button the P1 weekday OFF time will flash Fig 54 WALLY MT WTE 1 4 Use the up and down buttons to set the desired OFF time 5 Press the OK button and the P2 weekday ON time will flash 6 Repeatthe process to set the P2 weekday P1 weekend and P2 weekend programs 7 When the P2 OFF time is set and the OK button is pressed the display will stop flashing and the remote will be in program mode The program settings are now stored in the remote handset and will not change unless the above process is repeated or the batteries are removed from the handset To switch out of program mode simply press one of the manual timer or thermostat mode buttons Please note that if the manual button is pressed it will turn the fireplace off Y TOWN a COUNTRY TCWS 54CE3 2 0313 44 LUXURY FIREPLACES 30 THERMOSTATIC MODE BUTTON 000 THERMOSTAT SYMBOL TCWS 54CE3 270313 44 Thermostatic Mode Only for use where permitted Operates the fireplace within a set tem perature range The fireplace is shipped with thermostatic mode function deactivated If this function is permitted for use in your area it can be acti vated by depressing the recessed button on the back of the hand held remote Fig 55 Once activated the thermostat s
6. 1 Connect the gas supply to the valve Fig 29 2 Turn on the gas supply and check that all connections are tight and leak free WARNING Use EXTREME CAUTION when using soap and water to do a leak test on the valve fittings There are electronics around and below the valve that can will be damaged if they come in contact with water WARNING The access panel including gasket must be reinstalled after conversion installation or servicing has been completed Failure to do so will cause overheating and premature failure of the control system Gas Pressure Check Note To test the gas pressure turn off the gas supply before removing the plug from the supply pressure test port or manifold pressure test port Verify gas pressures with the fireplace lit and on the highest setting SUPPLY Please refer to the Burner Installation Manual for gas pressure testing procedure PRESSURE MANIFOLD PRESSURE Correct gas pressure requirement Natural Gas Propane Min Pressure 5 0 WC 12 5 WC For purpose of input adjustment Max Pressure 13 9 WC 13 9 WC Manifold Pressure Maximum 3 8 WC 11 WC Minimum 2 1 WC 5 5 WC TCWS 54CE3 270313 44 GAS VALVE INLET TOWN amp COUNTRY LUXURY FIREPLACES 17 Y lt Before installing venting for this unit the installer should read these instructions to insure that the proper vent configuration has been selected Use only Town and Country Termin
7. Certified for Certifi pour Canada and U S A WH This Appliance is Equipped For Use With Cet Appareil est Equip Pour Utilise Avec NATURAL GAS GAZ NATUREL LP GAS LP GAZ FOR USE WITH EN CASE D EMPLOI AVEC NATURAL GAS DU GAZ NATUREL LP GAS DU GAZ LP Minimum supply pressure Pression minimum d alimentation For the purpose of input adjustment dans le but de r gler l alimenation Maximum supply pressure Pression maximum d alimentation Manifold pressure Pression de la tuyauterie Maximum 5 0 ee 0 po c e 1 25 kPa 13 9 9 3 45 3 8 in wc 3 8 po c e 125 inwe 4 12 5 po c e 3 11 13 9 113 9 po c e 3 45 kPa 11 0 in wc 11 0 po c e 95 kPa 2 74 kPa Orifice Size Diametre de l injectuer 7 64 2 78 mm 1 65 mm SERIES C2 SERIE MADE IN CANADA FABRIQUE AU CANADA Optional components Power Vent El ments facultatifs Par Soufflierie TCVT WSPVB1 TCVT PVB2 TCVT FMPV TCVT FMPV3 TCVT PVC1 TCVT PVC2 TCVT PVC3 Blower electrical rating 115v 60hz 1 1 A Normes electriques du ventilateur 115v 60hz 1 1 A This appliance equipped for altitudes 0 4500 ft 0 1372 Cet unit est concu pour des altitudes variant entre 0 4500 pieds 0 1372 m In Canada also certified for installation in a bedroom or a bedsitting room Aussi certifi pour installation dans une chambre coucher ou une salle de s
8. MODULAR DIRECT VENT 270313 44 TCWS 54CE3 5056 425215 TOWN amp COUNTRY LUXURY FIREPLACES Table of Contents O A A A 3 o A y 3 Important Note for the Commonwealth of Massachusetts 4 Fireplace Dimensions 5 Minimum Clearances to Combustible 5 Installation Requirements ss 6 Manufactured Mobile Home 6 Window Frame ASIMOV all conionioma psp 6 Locating 7 O 7 Framing and Finishing ta aaa 8 Steel Stud Framing Kitu uu uu lin 10 Adjustable Linte same ae 13 14 Plumbing and Electrical nas nu 14 Gas S pp V eat 17 Gas Pressure na 17 A O 18 Wall Termination 18 Roof Termination Venting Chart 19 Vent Terminal Clearance 22 Vent a tn 23 Vent Restrictor Adjustment 24 Firebox Panels Instalando 25 Finishing Touch Trim Kit Instructions 26 27
9. 5019 013 SHOWN KIT CONTENTS 1 TCWS BODY ASSEMBLY la SPRING LATCH ASSEMBLY 2 16 CONTROL BOX 2 GLASS ASSEMBLY c w gasket FRAMING KIT 3a STEEL STUDS 3b NON COMBUSTIBLE BOARD SETS PANEL FRONT BASE PANEL LEFT SIDE PANEL UPPER PANEL REAR PANEL RIGHT SIDE TCWS 54CE3 270313 44 33 A TOWN amp COUNTRY lt LUXURY FIREPLACES Replacement Parts Maestro Control System WHEN ORDERING INCLUDE PART NUMBER WITH DESCRIPTION ITEM DESCRIPTION PART NO ITEM DESCRIPTION u PART NO 1 CONTROL ASSEMBLY TCRP 9271A 5 COMMUNICATION CABLE KIT 5005 06 2 BULKHEAD ASSEMBLY KIT TCRP 9284 6 CONTROL BOX KIT TCRP 8270 7 REMOTE HAND SET 5005 05 4 WALL SWITCH ASSEMBLY KIT TCRP 5005043 8 TEST FITTING 5019 104 KIT CONTENTS 1 CONTROL ASSEMBLY KIT BULKHEAD ASSEMBLY KIT COMMUNICATION CABLE KIT VALVE c w FITTINGS 2a INLET PLATE 1 4 FLEX TUBE 2b INLET PLATE GASKET 1 2 FLEX TUBE 2d 1 2 BULKHEAD FITTING CONTROL BOX KIT CONTROL MOUNTING BRACKET 2e 1 4 BULKHEAD FITTING IGNITION MODULE WIRI
10. COUNTRY TCWS 54CE3 2 0313 44 36 Vent Pipe Dimensions TCWS 54CE3 270313 44 TCVT 811X12ADJ 10 15 16 _ TCVT 811X _ 12 9 16 13 1 8 TCVT 811XLB45 37 12 PIPE 10 1 4 18 PIPE 16 1 4 24 PIPE 22 1 4 48 PIPE 46 1 4 TOWN COUNTRY 6 LUXURY FIREPLACES Vent Offset Chart A B 12 PIPE 18 5 8 18 18 PIPE 22 7 8 22 3 8 24 PIPE 27 1 8 26 1 2 48 PIPE 44 1 16 43 1 2 TOWN amp COUNTRY LUXURY FIREPLACES ADDING AN ADJUSTABLE SECTION TO PIPE WILL INCREASE OFFSET BY 2 1 8 TO 6 3 4 1 1 4 A B 12 PIPE 137 16 23 1 4 18 PIPE 179 16 27 5 8 24 PIPE 21 7 8 31 3 4 48 PIPE 38 3 4 44 7 8 ADDING AN ADJUSTABLE SECTION TO PIPE WILL INCREASE OFFSET BY 2 1 8 TO 6 3 4 de 1 1 4 gt L L 2 TCWS 54CE3 2 0313 44 38 Quick Panel Removal for Valve Service 1 Remove front panel base Also remove rear panel base if Black Diamond Burner is FRONT PANEL BASE fitted Fig 64 2 Push up on the heat shield at the right end of the unit near the middle enough to clear the securing tab Fig 65 3 Pull the top of the right panel toward the center of the unit using caution not to scratch the back panel Fig 66 4 Once the right panel i
11. EXAMPLES OF COMMON LOCATIONS O SEE FIG 11 FOR DIMENSIONS TCWS 54CE3 270313 44 TOWN amp COUNTRY lt LUXURY FIREPLACES Framing and Finishing Note The fireplace should be in place and venting installed before framing in or building an enclosure around the unit The Town amp Country fireplace must be framed in as described below or totally enclosed with non combustible material such as facing brick Determine the total thickness of facing material to be used A thickness of 3 4 will allow the finishing surface to be flush with the front of the unit If preferred additional masonry type non combustible material can be installed above and to the sides up to 6 inches forward of the appliance The finishing material must not interfere with glass frame access A Steel Stud Framing Kit is supplied with the fireplace and must be used unless the fireplace is totally enclosed with non combustible material Assemble the framing kit as per the instructions on pages 10 13 of this manual Attach the steel frame to the fireplace once the fireplace is in its final NON COMBUSTIBLE ZONE DO NOT INSTALL ANY position Secure the steel frame to the framing brackets on each side of the unit Ensure that the studs are set back far enough to allow for thickness of finishing surface The sid
12. amp COUNTRY FIREPLACES Fig 28 TOWN amp COUNTRY FIREPLACES TOWN amp COUNTRY LUXURY FIREPLACES 15 Pre Purge Mode For use with a power vent only Follow these instructions to activate the power vent pre purge feature This feature must be activated for the safe operation of an appliance equipped with a power vent Switching to the power vent pre purge mode To turn feature ON OFF press and hold the STANDING PILOT button on the wallswitch for 10 seconds Fig 28a When the feature is activated the green LED should flash 0 5 seconds ON 0 5 seconds OFF 5 times When the feature is deactivated the red LED should flash 0 5 seconds ON 0 5 seconds OFF 5 times When the pre purge feature is ON The low battery backup warning feature will be disabled and the LED will not flash to indicate low battery The battery backup must be removed when using a power vent The Standing Pilot feature will be de activated feature not available when Power Vent Pre Purge Mode is active Upon receiving any ON command the power vent output will close immediately butthe ignition cycle will NOT begin for 10 seconds pre purge This means that the moduleWILL NOT emita spark and WILL NOT energize the pilot operator and the 60 second ignition trial period WILL NOT begin until the 10 second pre purge delay is complete Upon receiving any ON command the green LED will flash 0 5 secon
13. building Shingle roof example shown Fig 34 2 Place the storm collar down over the vent pipe until it is level Tighten storm collar for a snug fit Apply a thick horizontal ring of mastic around the pipe at top of the storm collar Fig 34 3 Lower the roof vent terminal cap over the vent pipe and secure in place with screws provided Fig 34 Seal screw heads and joint with caulking to prevent any moisture entering the venting system Fig 34 VERTICAL TERMINATION CAP TCVT 9365 VENT PIPE STORM COLLAR SSK TC42 90665 FLASHING NOTE ADJUSTABLE FOR VARIOUS ROOF PITCHES FROM FLAT ROOF TO 12 12 PITCH ROOF Y TCWS 54CE3 270313 44 TOWN a COUNTRY lt 21 Vent Terminal Clearance ini i intaj i Fig 35 Minimum clearances to the vent terminal must be maintained as shown VENT TERMINAL MINIMUM CLEARANCES TO ADJACENT STRUCTURES figure 35 Measure clearances to the nearest edge of termination hood NOTE Vent terminal must not be recessed NOTE LOCAL CODES OR REGULATIONS MAY REQUIRE DIFFERENT CLEARANCES emi Terminal to Sloped Roof itch Table minimum ft m Flat to 6 12 1 00 0 30 Over 6 12 to 7 12 1 25 0 38 Over 7 12 to 8 12 1 50 0 46 Over 8 12 to 9 12 2 00 0 61 Over 9 12 to 10 12 2 50 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 00 1 22 36 91 5 cm A _ See Fig 36 24 61 Vent System Components 12 Pip
14. by a licensed or qualified service person Do not strike or otherwise impact the glass in anyway that may cause it to break If the glass becomes cracked or broken it must be replaced before using the fireplace Replacement glass can be obtained from your nearest Town amp Country Fireplaces dealer The size required is 52 x 16 x 5mm Use ceramic glass only Do not substitute with any other type To remove broken glass remove window frame as noted in Window Frame Removal section Unclip the Glass Retainer Clips located at the top and sides of the Window Frame Pull the top edge of the glass out of the frame first then lift it up and out of the bottom edge Install the new piece of glass with the gasket into the frame so that the thicker bead of gasket faces the fireplace Re install glass retaining clips Annual Inspection a Remove glass panel and pebble assemblies Inspect pebble and burner assemblies for soot buildup If excessive buildup of soot is present have a qualified service person inspect and adjust unit for proper combustion Clean logs and burner with a brush or vacuum cleaner paying close attention to burner ports b Check the pilot system for proper flame size and operation Clean pilot free of soot dust or any other deposits See Fig 59 c Check that the vent pipe and vent terminal are open and free from blockage or debris If the venting is disassembled for cleaning it must be properly assembled and r
15. jour This appliance must be installed in accordance with local codes if any if none follow the current CAN CGA B149 Canada or ANSI Z223 1 USA Installation Codes Installer l appareil selon les codes ou r glements locaux ou en de tels r glements selon les codes d installation CAN CGA B149 Canada ANSI 2223 1 USA en vigeur Input BTU hr kW Entree BTU h kW Max Min Max Min 54 900 16 1 46 200 13 5 54 900 16 1 46 200 13 5 MANUFACTURED MOBILE HOME This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes See owners manual for details FABRIQUEZ MOBILE MAISON Cet appareil doit tre utilis uniquement avec le type de gaz indiqu sur la plaque signal tique et peut tre install dans une maison pr fabriqu e mobile install e a demeure si les reglements locaux le permettent Voir la notice du propri taire pour plus de d tails Cet appareil ne peut tre converti d autres gaz sauf si une trousse de conversion certifi e est utilis e Install in accordance with the current standard Mobile Homes CAN CSA Z240 MH in CANADA and the Manufacturer s Home Construction and Safety Standard Title 24 CFR Part 3280 or the current Standard for Fire Safety Criteria for Manufactured Home Installations Sites and Commun
16. up and out to disengage from its bottom track Place the window frame in a safe place to avoid damage Re assemble reverse order Latch handle should snap into place and be flush with window frame when engaged correctly TIP To ensure glass is propery latched grasp the top left and right sides of the glass frame under moderate pressure it should pull forward and return to original position evenly on both sides 6 Reinstall Trim Kit if required Y TOWN a COUNTRY TCWS 54CE3 2 0313 44 LUXURY FIREPLACES The standoffs are shipped loose inside the fireplace and must be installed on the top and the side of the fireplace as shown in Fig t6 Do this once the fireplace is on site and in position TOP STANDOFFS SIDE STANDOFF THIS SIDE ONLY CONTROL BOX HANDLE Locating The Fireplace In planning the installation for the fireplace it is necessary to determine where the unit is to be installed location of vent system and where gas supply piping may be plumbed Various installations are possible such as into an existing wall a corner a built in wall or a wall projection Fig 7 Due to high temperatures do not locate this fireplace in areas of high traffic or near furniture or draperies The minimum clearances from the fireplace to combustible surfaces must be adhered to and are shown in Fig 2 and Fig 3
17. 7 Press the center button on the wall control Fig 26 The igniter will start to spark After a short time the pilot will light followed by the main burner 18 Press the up button on the wall control and hold it for 5 seconds or until a clicking sound is heard from the gas control Fig 27 Release the button check manifold pressure and ensure that it s correct Refer to Burner installation manual OWN amp COUNTRY FIREPLACES 19 Pressthe center button ofthe wall control The fireplace will shut off 20 Installthe remaining screws the access panel and tighten 21 Remove the pressure gauge and the extension test fitting and thread the pressure test port plug into the pressure test port Thread sealant is required on the threads Refer to Burner installation manual 22 Turn the fireplace on and verify that the connections are tight Standing Pilot Function Only for use where permitted The control system on this fireplace is set to operate as electronic ignition If required the system can be converted to a standing pilot by depressing a recessed button located on the lower right hand side of the wall control Fig 28 This should be depressed with a paperclip pencil or other thin object Once activated the pilot will run continuously Please check with your local inspector to ensure that this is permitted in your area LEARN BUTTON STANDING PILOT BUTTON TCWS 54CE3 270313 44 Fig 24 TOWN
18. 8 to install the non combustible bo 8 This fireplace may be recessed up to a maximum depth of 6 this recess must be constructed from non combustible material The space between the outside lintels and the firebox must be completely free of any obstructions or debris and the window with trim fitted must be able to move freely No build ing material is permitted to protrude past the lintel bars attached to the fire place under ANY circumstance NON COMBUSTIBLE FINISH MATERIAL TOWN amp COUNTRY LUXURY FIREPLACES TCWS 54CE3 2 0313 44 12 Adjustable Lintel 1 The adjustable lintel assembly has two orientations for desired finishing A flanged edge and a hemmed edge The lintel comes factory installed with the flange edge out If the desired edge is different from the factory setting use the following steps to change it Fig 21 2 Remove the window trim Fig 22 3 Loosen the securing bolts in the upper and lower corners on each side of the lintel and remove the lintel Rotate the assembly to have the desired edge away from the fireplace Fig 23 4 The lintel assembly has a maximum range FLANGED EDGE of adjustability of 1 to accommodate varying facing material thicknesses The maximum depth is 6 Fig 25 5 The lintel assembly can then be adjusted to align flush with your facing material by sliding in or out approximately 1 6 Tighten the securing bolts
19. Fig 23 Z Re attach the window trim Fig 18 TCWS 54CE3 270313 44 TOWN amp COUNTRY Y 13 Maestro Control Plumbing and Electrical The gas control system is located on the right hand side of the firebox behind an access panel and the decorative firebox panel if installed The fireplace is operated via a wall switch and a hand held remote control unit The wall control is connected to the fireplace by a 25 ft communication cable supplied with the fireplace The communication cable can be extended with an optional 25 ft extension kit Installation ACCESS PANEL Fig 21 1 Place the fireplace in the desired location 2 Remove the window from the fireplace 3 Remove access panel from right hand side of the firebox Fig 20 4 Lift the control box heat shield from the bottom opening to clear the location tabs and pull inwards Lower the heat shield to clear the top tab Lift the heat shield and locate on the screw above the opening Fig 21 amp 22 NOTE The flex lines may have to be pushed down to allow the shield to be lowered enough to clear the top tab 5 Connect an unswitched 110 V AC electrical supply to the outlet installed inside the control box The supply should be wired to the latest version of National codes CSA 22 1 70 and or local codes Fig 23A The electrical wires can be accessed from both inside and outside the control box by remo
20. I UL 2034 listed as IAS certified 3 SIGNAGE metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5 089 2 a 1 through 4 b EXEMPTIONS The following equipment is exempt from 248 CMR 5 089 2 a 1 through 4 1 The equipment listed in Chapter 10 entitled Equipment Not Required To Be Vented in the most current edition of NFPA 54 as adopted by the Board and 2 Product Approved side wall horizontal vented gas fuelled equipment installed in a room or structure separate from the dwelling building or struc ture used in whole or in part for residential purposes MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment the instructions p
21. INSTALLER Leave this manual with the appliance A CONSUMER Retain this manual for future reference WARNING I the information in these TOWN amp NTRY instructions is not followed exactly a fire or LUXURY FIREPLACES explosion may result causing property damage personal injury or death FOR YOUR SAFETY Installation and service must be performed by a qualified installer service agency or the gas supplier SERIAL WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch L Do not use any phone in your building e immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions TCWS 54 If you cannot reach your gas supplier call the fire department INSTALLATION Donotstore or use gasoline or other flammable AND PERATIN G vapors and liquids in the vicinity of this or any other appliance INSTRU CTIONS This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used This appliance is suitable for installation in a bedroom or bed sitting room MODEL TCWS 54CE3 5 SERIES
22. LL ANY COMBUSTIBLE MATE FINISH WALL ABOVE STANDOFFS RIAL ELECTRICAL WIRING OR GAS PLUMBING STANDOFFS IN THIS AREA MAY USE COMBUSTIBLE FACING MATERIAL IN THIS AREA 2 Y NON COMBUSTIBLE sS FINISH MATERIAL SEE FIG 8 amp 9 i i e TOP OF LINTEL BAR L DEPTH 12 6 3 4 1 1 2 Z SS MANTEL CLEARANCE 9 6 3 FIREPLACE FRONT Minimum Clearances Side Eai 0 CEILING Back 0 WALL 0 mm Bottom Of appliance iia 0 mm Adjacent side 4 in 102 mm Ceiling to applla ee u uuu u uuu 24 in 610 mm Mantel to appliance See Figure 2 LE HEARTH Maximum Mantel extension See Figure 2 Mantel SUPDOM a a a sm astana su Tauka 4 in 102 mm raso wie Vertical vent pipe 1 3 4 in 45 NONCOMBUSTIBLE MASONRY TYPE MATERIAL TCWS 54CE3 270313 44 TOWN amp COUNTRY 4 Installation Requirements The Town amp Country Fireplace installation and venting must conform to the current CAN CGA B149 installation code in Canada or the current National Fuel Gas Code ANSI 2223 1 in the USA and approved per local codes Only qualified licensed trained
23. NG HARNESS UTILITY BOX ASSEMBLY REMOTE HAND SET IGNITION SENSOR WIRES 3a UTILITY BOX PRESSURE TEST ASSEMBLY 3b ELECTRICAL RECEPTACLE AC ADAPTOR 3c COVER PLATE TEST FITTING PLATE A PLATE B WALL SWITCH ASSEMBLY WING NUTS 2 4 BATTERY HOLDER MINIMUM SCREW NG 4b WALL SWITCH COVER PLATE 4c WALL SWITCH Y TOWN a COUNTRY TCWS 54CE3 2 0313 44 34 YMS SHUN m ing Diagram Ir Jojp uuoo Jojp uuoo SIEN aJeWway Jojp uuoo Jojp uuoo 891 1199 3 UM Jolo uuooO Jolo uuoo SEW 7 ajeuay asm YOUMS 1 5 JOJdepy OV apis aunssald LON YO 2 7 OMV 18 9 Aq 18M04 ou Jamod 0 J98UU09 pede ve ZH 09 HOA SLL Y TOWN amp COUNTRY q LUXURY FIREPLACES TCWS 54CE3 270313 44 35 Roof Termination Kit TCVT RTA VERTICAL TERMINATION CAP TCVT 9365 STORM COLLAR ROOF SUPPORT CEILING FIRESTOP BRACKET TCVT THIMA TCVT 93915 Y TOWN a
24. Seat tabs can be lowered if the rear panel is tight NOTE Centering tabs on the panel should be located at the outside of the seat tabs 4 While supporting the back panel insert the left side panel into the firebox Position the top of the panel against the side of the unit inserting the top panel tab into the slot at the top of the side panel and slide the bottom into position Fig 44 NOTE Notch at bottom of side panel faces to front of unit 5 Repeat step 4 for the other side panel NOTE Install burner now 6 Place the front panel on the front lip of the firebox wide flange facing the front Fig 45 Proceed to step 7 if you are installing TCWS 54NG03 C2 Black Diamond burner with this unit 7 Place the other front panel piece at the rear of the firebox with the wide flange facing to the rear against the back panel 77 TCWS 54CE3 270313 44 TOWN amp COUNTRY LUXURY FIREPLACES 25 Finishing Touch Trim Kit Instructions 1 Place two smaller magnets on back of each side rail 2 Place two larger magnets on back of the top and bottom rails 3 Attach the side rails Even the ends up with the door frame 4 Attach the top and bottom rails and adjust so mitres are even at the corners 5 Place TC magnetic logo in bottom right corner Larger Magnets Top or bottom rail 9 Side rails 7 TOWN amp COUNTRY Lu s XURY FIREPLACE TCWS 54CE3 2 0313 44 26
25. Supplied with fireplace ALL OTHER FRAMING CAN BE DONE WITH CONVENTIONAL LUMBER TCWS 54CE3 2 0313 44 NON COMBUSTIBLE BOARD DETAIL NON COMBUSTIBLE BOARD NON COMBUSTIBLE MATERIAL MUST EXTEND 12 ABOVE 9 5 8 TO THE SIDES AND 12 BELOW THE FRAMING EDGES Fig 10 NON COMBUSTIBLE RECESSED INSTALLATION DETAIL NON COMBUSTIBLE BOARD STEEL STUDS NON COMBUSTIBLE MASONRY TYPE MATERIAL MAXIMUM FACING DEPTH MINIMUM COMBUSTIBLE 80 5 8 FRAMING DIMENSIONS INCLUDING SHEETROCK 22 1 16 11 5 16 NOTE FIREPLACE SHOULD BE IN ITS FINAL LOCATION BEFORE FRAMING TCWS 54CE3 270313 44 IT IS RECOMMENDED TO USE FULL SHEETS OF CALCIUM SILICATE BOARD OR ITS EQUIVALENT AND FULL LENGTH METAL STUDS TO AND FRAME AROUND THE FOLLOW THE MANUFACTURERS MOUNTING AND FINISHING IN STRUCTIONS CLOSELY NON COMBUSTIBLE BOARD LUXURY FIREPLACES Steel Stud Framing Kit Each Kit Contains 20022200 TOWN amp COUNTRY LUXURY FIREPLACES TCWS 54FRKIT 10 Pent Description 1 5049 9912 SCREW WAFER 8 x 1 2 Pkg 40 8293 4 STUD SIDES 55 L 8293 2 STUD OUTER SIDES 55 L 4 8293 STUD UPPER LOWER 75 1 4 5 8293 6 INNER CROSS BRACE 1 56 5 8 L STUD CENTER 25 L LOWER CROSS BRACE 56 5 8 L SCREW DRYWALL 1 1 4 Pkg 30 TCWS 54CE3 2 0313 44 NOTE Sheet metal parts have sharp e
26. ation kits TCVT RTA Roof Termination Kit Vent system components approved for use with the Town and Country Fireplace are shown in Fig 31 NOTE Optional Power Vents TCVT PVB2 TVCT PVC1 TCVTPVC2 and TCVT PVC3 require different venting Please refer to Power Vent manuals Various combinations of vent runs may be used Refer to Fig 31 for details For optimum performance and flame appearance keep the vent length to a minimum and limit the number of elbows Connections between each vent system component must be tightly joined secured with sheet metal screws and sealed with high temperature self adhesive tape VENT SUPPORTS A minimum of 1 support every 4 must be used CAUTION UNDER NO CONDITION SHOULD COMBUSTIBLE MATERIAL BE CLOSER THAN 1 3 4 INCHES FROM ANY PART OF THE VENT PIPE Wall Termination Venting This fireplace can only be wall terminated using the TCVT PVOC1 TCVT PVOC2 or TCVT PVOC3 power vent kit Please see the instructions supplied with the kit for installation details Y TOWN a COUNTRY TCWS 54CE3 2 0313 44 18 Roof Termination Venting Chart Various combinations of vent runs may be used Refer to Fig 31 for details For optimum performance and flame appearance keep the vent length toa minimum and limitthe number of elbows Connections between each vent system component must be tightly joined secured with sheet metal screws and sealed CAUTION Under no condition should
27. clean It is our policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable inadequate or unsafe condition which is the result either directly or indirectly of any improper operation or installation procedures This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance TCWS 54CE3 270313 44 NATIONAL FIREPLACE INSTITUTE A CERTIFICATION AGENCY We recommend that our gas hearth products be installed and serviced by professionals who are certified in the United States by the National Fireplace Institute NFI as NFI Gas Specialists HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS Y TOWN amp COUNTRY q LUXURY FIREPLACES Important Note for the Commonwealth of Massachusetts From Massachusetts Rules and Regulations 248 CMR 5 08 a For all side wall horizontally vented gas fuelled equipment installed in every dwelling building or structure used in whole or in part for residential purposes including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven 7 feet above finished grade in the area of the venting including but not limited to decks and porches the following requirements shall be satisfied 1 INSTALLATION OF CARBON MONOXIDE DETECTORS At the ti
28. combustible material be closer than 1 3 4 inches from any part of the vent pipe Only 45 elbows can be used in this vent system Maximum number of elbows is 2 MINIMUM VENT HEIGHT 18 MIN BEFORE ELBOW TCWS 54CE3 270313 44 48 MAX 40 10 2 gt TOWN COUNTRY lt LUXURY FIREPLACES 19 Ceiling Opening 1 Determine the exact position of the fireplace so that the vent pipe is centered if possible between two building framing members Lay out the vent system path minimizing the number of elbows and length of vent Consult your local building codes prior to proceed ing 2 Cut and frame a 14 1 2 opening in the floor ceiling or roof where the vent system will pass Size of the opening in the roof may need to be increased as the pitch of the roof increases Avoid cutting rafters Ceiling Firestop Where a vent pipe passes through a floor or ceiling a ceiling firestop TCVT THIMA must be used to retain insulation and maintain proper clearances Size of the opening will have to From below push the ceiling firestop through the opening and secure in place If the firestop increase with the pitch of the is used to penetrate a floor the outer shield may be trimmed in length If the firestop pen roof to ensure a 1 3 4 inch air etrates into an attic leave the shield full len
29. dges use caution when handling 1 Frame Assembly Place 2 of 4 together a top Place 1 of 6 into the joint with the long edge facing up Align the 3 holes and screw together with wafer screw 1 Attach the remaining the same manner at holes to the left and right of the center Attach 2 with wide edge face up Attach 5 to 6 and 2 Attach 7 to 2 using 1 screw through the top and 1 screw through the side at each end Attach 3 1 each side with bend out tabs to the front Place 2 remaining pieces of 4 together at the bottom of the framing kit in the same manner as the top screw them together and attach to the inner steel studs e Turn the framing kit over and secure all studs from the back FRONT VIEW slightly angled BEND OUT FRAMING TABS TO FRONT WIDE FACE FORWARD SLOTS UP SCREW INTO TOWN amp COUNTRY E LUXURY FIREPLACES 11 TCWS 54CE3 270313 44 2 Attach the Assembled Frame to the Unit Align the assembled frame to the unit framing brackets Fig 13 Attach at the fastening points through the access holes in the outer side studs 3 3 Secure to Existing Framing e Bend out the tabs 90 degrees before inserting the unit into its framed housing Fig 14 e Secure the frame assembly to the wood frame through the tabs 4 Install Non Combustible Board not supplied e Use drywall screws
30. dproof Lock An additional feature of this remote control is the childproof lock To activate this system press and hold the timer and thermostat buttons for approx 5 seconds until the lock symbol ap pears on the remote display Fig 49 The remote control hand set buttons are now locked and the lock symbol will reappear every time a button is pressed on the remote control until the timer and thermostat buttons are pressed and held again Note The fireplace can still be operated normally using the wall control even with the remote control buttons locked Maestro Control System Operation Each Town 8 Country Maestro Control system comes equipped with a manual mode on the wall control and hand held remote and three programmable modes accessible with the hand remote Manual Mode On remote and wall control Basic operation of the fireplace can be performed with the wall control or remote hand set ON OFF as well as flame modulation UP DOWN The center button on the remote control can be used to turn the fireplace ON and OFF With the fireplace off press the center button to turn it on The MAN and flame icons will be displayed on the screen A second push will turn it off The MAN and flame icons will disappear from the screen When the fireplace is on the up and down buttons located above and below the center but ton are used to modulate the flame height Fig 50 Countdown Timer Mode Operates the fi
31. ds ON 0 5 seconds OFF for 10 seconds so the user will know that the fireplace is operating TOWN amp COUNTRY LUXURY FIREPLACES Fig 28 TOWN COUNTRY FIREPLACES STANDING PILOT BUTTON NOTE The pre purge feature must be activated for the safe operation of an appliance equipped with a power vent TCWS 54CE3 2 0313 44 16 Gas Supply Caution The gas line should be installed by a qualified service person in accordance with all building codes This section is intended as a guide for qualified technicians installing this appliance Consult local and or national building codes before proceeding e Gas supply line access holes are located at the top and left sides of the Control Box Gas valve inlet accepts 3 8 fitting Correct gas line diameter must be used to assure proper operation and pressure e fireplace has an input rate of 54 900 BTU HR on both Natural Gas and Propane e NOTE A sediment trap as per national fuel gas code must be installed in the gas supply line no more than 6 feet from the gas control valve to minimize the possibility of any loose scale or dirt within the gas supply line from entering the control valve DO NOT HARD PIPE GAS LINE TO VALVE A method of disconnecting the valve from the gas line such as a union or flare fitting must be provided to allow for repair or replacement of the gas valve Check local codes for additional requirements
32. e Length 18 Pipe Length 24 Pipe Length 48 Pipe Length 12 Adjustable Pipe Length Wall Offset Support A minimum of 1 support every 4 must be used Roof Termination Kit Wall Shield Ceiling Firestop Roof Flashing Adjustable Roof Flashing Flat Roof Flashing Steep TOWN amp COUNTRY LUXURY FIREPLACES Town amp Country TCVT 811X12 TCVT 811X18 TCVT 811X24 TCVT 811X48 TCVT 811X12ADJ TCVT 811XLB45 811 5 TCVT RTA TCVT THIMA TCVT 811FLADJ TCVT 811FLFLT TCVT 811FLSTP or any flashing that fits 11 pipe TCWS 54CE3 2 0313 44 22 Vent Pipe Sealant APPROVED HIGH TEMP VENT PIBE SELF ADHESIVE TAPE SUPPLIED outer joints of the vent pipe must be sealed with the approved High Temperature self adhesive aluminium tape provided Wrap the tape completely around the joint and press firmly in place Inner pipe does not need to be sealed TCWS 54CE3 270313 44 23 7 TOWN amp COUNTRY lt LUXURY FIREPLACES Vent Restrictor Adjustment The vent restrictor is located on the underside of the firebox top The unit leaves the fac tory with the vent restrictor open The restrictor is built into the appliance for secondary air flow adjustment Adjustment enables tuning the airflow for optimum flame appearance and WALL AND ROOF performance for a wide variety of vent configurations TERMINATION RESTRICTOR POSITION Setting
33. e sealed Refer to VENTING section for proper procedure FLAME SENSOR PILOT FLAME d Check glass panel gasket replace if necessary It is important that the glass seal be maintained in good condition e Check and replace batteries as needed ELECTRODE Note The appliance area must be kept clear and free from combustible materials gasoline and other flammable vapours and liquids Periodically a Viewing glass may be cleaned as necessary with fireplace glass cleaner b Exterior finish may be cleaned with mild soap and water CAUTION Do not use abrasive cleaners on glass or any other part of the fireplace Do not clean glass when hot Y TOWN a COUNTRY TCWS 54CE3 2 0313 44 LUXURY FIREPLACES TCWS 54CE3 Replacement Parts WHEN ORDERING INCLUDE PART NUMBER WITH DESCRIPTION ITEM DESCRIPTION PART NO ITEM DESCRIPTION PART NO 1 2 3 4 TCWS BODY TCWS 54CE3 GLASS ASSEMBLY c w gasket GLAS 2062ASSY FRAMING TCWS 54FRKIT PANEL SETS BLACK PORCELAIN TCPN 775 C BROWN PORCELAIN TCPN 775CB C 5 TOUCH TRIM KIT TCRP 54WSTRIMKIT 6 ORIFICE 2 5 5022 87 7 MAIN GAS SUPPLY TUBES 3pcs 5019 223 8 BURNER SUPPORT ses 9498 9 PILOT ASSEMBLY TCRP 5005025G ies
34. emote to lowest setting If the burner does not light repeat steps 4 through 6 This appliance is equipped with an ignition device which If the burner will not light or stay lit after several automatically lights the pilot Do not try to light the pilot by tries push the On Off switch to the fireplace off and hand call your service technician or gas supplier Push the On Off switch to the fireplace Off Note Sufficient time must be allowed for air to escape Allow sufficient length of time minimum 5 minutes for any from lines if the unit is being lit for the first time gas in the combustion chamber to escape If you still smell Set fireplace to desired setting by using either the wall gas STOP Follow in the safety information above on switch or hand held remote this label If you don t smell gas go to the next step Set wall switch hand held remote to lowest setting 3 Turn off all electric power to the appliance and remove Push the on off switch to the Off position backup batteries if service is to be performed or for extended shutdown Due to high surface temperatures keep children clothing and furniture away Keep burner and control compartment clean See installation and operating instructions accompanying the appliance A cause de la temperature elevee des parios tenir eloignes les enfants les vetements et les meubles Maintenir propres le bruleur et le compartiment de commande Voir les instructions re
35. es back and top of the fireplace can be framed in up to the steel studs and the fireplace standoffs using conventional lumber Consult local building codes for specific requirements Due to high temperatures non combustible backer board such as cement board or its equivalent must be used to sheet in the front of the fireplace extending 12 below 12 above and 9 5 8 to the side of the framing edge bars Fig 9 Standard sheetrock dry wall may be used beyond this If the backer board is not to be finished with other non combustible material such as tiles it is recommended that the instructions in Fig 9a be followed closely COMBUSTIBLE MATERIAL ELECTRICAL WIRING INSULATION PLASTIC VAPOR BARRIER OR GAS PLUMBING WITHIN THE STEEL STUD FRAMING TOWN amp COUNTRY LUXURY FIREPLACES Chase Insulation When installing this fireplace against anon insulated exterior wall or chase it is recommended that the outer walls be insulated to the same degree as other exterior walls Do not place fireplace directly against the insulation Cover the insulation and plastic vapour barrier with a solid surface such as dry wall sheetrock Consult local codes Do not insulate or use plastic vapour barrier within the framing kit CAUTION SEE FIGURE 9a BEFORE PROCEEDING NOTE The chase must be properly sealed at the ceiling level or between floors in a multilevel installation STEEL STUD FRAMING KIT DIMENSIONS
36. gth to keep insulation away from the vent pipe space clearance between vent Additionally after the vent pipe is in place install a storm collar on top of the shield This will pipe and combustibles prevent loose insulation from falling into the area between the vent pipe and the shield Roof Pitch A B 0 12 14 1 2 7 1 4 4 12 16 1 2 8 3 4 6 12 18 10 8 12 19 3 4 11 12 12 24 13 3 4 Vent Pipe VENT PIPE 1 Install the first section of vent pipe into the collar on top of the fireplace Secure in place with screws and seal with ap proved High Temperature self adhesive aluminium tape provided 2 Continue adding vent pipe lengths up and through the firestop s and through the roof The vent pipe must extend above the roof according to the sloped roof table in Fig 36 Seal the vent pipe as per Vent Pipe Sealant section Roof Support Bracket Slip the roof support bracket down over the vent pipe Rotate the 90 brackets to accom modate roof pitch Attach the brackets to the roof joists with nails or building screws Tighten the band around the vent pipe and secure in place with screws ROOF SUPPORT BRACKET TCVT 93915 TOWN amp COUNTRY LUXURY FIREPLACES TCWS 54CE3 2 0313 44 20 Roof Vent Terminal 1 Place the roof flashing over top of the vent pipe seal it to the roof using the meth ods and materials appropriate for the type of roof on the
37. ities ANSI NFPA in the U S A Cet appareil diot tre install conformem nt aux exigences de la norme CAN CSA 2240 vigueur de Installations de gaz dans les Constructions Mobiles FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFI ES AVEC LAPPAREIL Pacific Energy Fireplace Products Ltd Duncan British Columbia Canada MINIMUM CLEARANCES TO COMBUSTIBLES CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE Left and Right side are determined when facing the front of the appliance Les c t s droit et gauche se d terminent en se mettant devant et en lui faisant face 0 in 0 po 4 in 4 po 9 in 9 po 12 in 12 po 0 mm 102 mm 229 mm 305 mm Top Back and Side Standoffs Sommet Arri re et C t But e Sidewall to Appliance Du mur lat ral a l appareil Mantel to Appliance Du manteau al appareil Maximum Mantel Extension Allongement maximum du manteau See Installation Manual for more detail Voyez des Directive de I Installation pour plus d taux Mantel Supports Supports du manteau Vent Pipe D chargez le Tuyau DDV TECHNOLOGY Accepted for Use City of New York Department of Buildings MEA 116 08 E Pacific Energy Fireplace Products Ltd 2 in 2 po 1 75 in 1 75 po 51 mm 45 mm WARNING Improper installation adjustment alteration service
38. latives a l installation et au fonctionnement qui accompagnent l appareil CAUTION Hot while in operation Do not touch Severe burns may result Keep children clothing furniture gasoline and other liquids having flammable vapours away Keep burner and control compartment clean See installation and operating instructions accompanying the appliance ATTENTION L appareil est chaud lorsqu il fonctionne Ne pas toucher l appareil Risque de br lures graves Serveiller les enfants Garder les v tements le meubles l essence ou autres liquides produisant des vapeurs inflammables loin de l appareil S assurer que le br leur et le compartiment des commandes sont propres Voir les instructions d installation et d utilisation qui accompagnent l appareil 310106 5051 173 5 TC30 When lit for the first time the fireplace will emit a slight odour for a couple of hours This is due to the curing of paints sealants and lubricants used in the manufacturing process This condition is temporary Open doors and windows to ventilate area Odour caused by the curing process may cause discomfort to some individuals It is normal for fireplaces fabricated of steel to give off some expansion and or contraction noises during the start up or cool down cycle Similar noises are found with your furnace exchanger or cook stove oven 74 TCWS 54CE3 270313 44 TOWN COUNTRY 6 27 Maestro Control System Remote Control Initial Setup
39. me of installation of the side wall horizontal vented gas fuelled equipment the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back up is installed on the floor level where the gas equipment is to be installed in addition the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling building or structure served by the side wall horizontal vented gas fuelled equipment It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors a In the event that the side wall horizontally vented gas fuelled equipment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level b In the event that the requirements of this subdivision cannot be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detec tor with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANS
40. or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or the gas supplier AVERTISSEMENT Une installation un r glage une modification une r paration ou un entretien mal effectu peut causer des dommages mat riels ou des blessures Voir la notice de Putilisateur qui accompgne l appareil Pour de l aide ou des renseignements suppl mentaires consultez un installateur un technicien agr ou le fournisseur de gaz 291012 5050 720378 CE3 1 TCWS 54CE3 Y TOWN amp COUNTRY q LUXURY FIREPLACES TCWS 54CE3 270313 44 43 Y TOWN amp COUNTRY LUXURY FIREPLACES Technical support 1 250 748 1184 Web site www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada
41. personnel should install this product In the state of Massachusetts only a licensed Plumber and Gas Fitter may install this product Manufactured Mobile Home In some jurisdictions the Town amp Country Fireplace may be installed in Manufactured Homes after the first sale Consult local codes for approval The fireplace must be fastened in place Install in accordance with the current standard Mobile Homes CAN CSA Z240 MH in CANADA and the Manufacturer s Home Construction and Safety Standard Title 24 CFR Part 3280 or the current Standard for Fire Safety Criteria for Manufactured Home Installa tions Sites and Communities ANSI NFPA 501A in the USA Window Frame Removal Warning Turn off the fireplace and allow ample time for the unit to cool before proceeding Caution The ceramic glass is very fragile and should be handled with care The window frame is held in place by two spring loaded latches that are operated by a one piece latch handle Remove the TC Finishing Touch Trim Kit from the window frame If installed D Using a screwdriver or other similar object push against the notch in the top of the latch and grab the bottom of the latch handle as it protrudes Lift handle until latch hook disengages Repeat for other side while holding glass so it does not tip out Fig 4 5 amp 5a Tilt the top of the window frame out to clear the top edge of the unit Grasp the sides of the frame and lift
42. replace for a preset length of time 1 Press the timer button and the time will flash on the lower center of the display Fig 51 2 When display is flashing use the up and down arrows to set the length of time you would like the fireplace to run The range is 10 minutes minimum to 180 minutes maximum Fig 52 3 Press the OK button and the timer is set and the control is in countdown timer mode 4 To exit the timer mode press the Program Manual or Thermostat buttons Please note that the first press of the Manual button will turn the fireplace off TCWS 54CE3 270313 44 Fig 50 FLAME DOWN TOWN amp COUNTRY lt LUXURY FIREPLACES 29 Program Mode To preset up to two on and off periods per day The program mode has two settings for weekdays and two for weekends The hand held remote comes with the following pre programmed settings Weekday Program Monday through Friday Program one P1 turns ON at 7 00am and turns OFF at 8 00am Program two P2 turns ON at 5 00pm and turns OFF at 7 00pm Weekend Program Saturday and Sunday Program one P1 turns ON at 9 00am and turns OFF at 10 00am Program two P2 turns ON at 6 00pm and turns OFF at 9 00pm PROGRAM Activate the programs by pressing the program button on the lower left hand side of the remote hand set Fig 53 To customize these settings 1 Hold the program button down until the display flashes
43. rovided by the manufacturer for installation of the equipment and the venting system shall include 1 Detailed instructions for the installation of the venting system design or the venting system components and 2 A complete parts list for the venting system design or venting system 9 MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED When the manufacturer of a Product Approved side wall horizontally vented gas fuelled equipment does not provide the parts for venting the fuel gases but identifies special venting systems the fol lowing requirements shall be satisfied by the manufacturer 1 The referenced special venting system instructions shall be included with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that system shall include a parts list and detailed installation instructions e A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment all venting instructions all parts lists for venting instructions and or all venting design instructions shall remain with the appliance or equipment at the completion of the installation Y TOWN a COUNTRY TCWS 54CE3 2 0313 44 LUXURY FIREPLACES Fireplace Dimensions 737 8 737 8 NON COMBUSTIBLE ZONE COMBUSTIBLE FRAMING AND STEEL FRAMING DO NOT INSTA
44. s tilted inwards it can be lifted clear of the burner tray and removed Fig 65 NOTE The right hand side rock cluster may need to be removed to prevent damage while working through the access hole Covering the sand with paper or cardboard will also minimize disturbance during the servicing process 5 The access panel is now visible Fig 67 and can be removed as described on Pg 13 6 Reassemble in reverse order WARNING The control box shield access panel and gasket must be replaced Failure Fig 66 to do so will overheat and cause premature failure of the control TCWS 54CE3 270313 44 TOWN amp COUNTRY 39 Y TOWN COUNTRY TCWS 54CE3 2 0313 44 LUXURY FIREPLACES Y TCWS 54CE3 270313 44 TOWN amp COUNTRY 41 Y TOWN COUNTRY TCWS 54CE3 2 0313 44 LUXURY FIREPLACES Safety Label Location NOTE The Safety Label is located on a plate found in a slot between the left hand side lintel and the left hand side window frame This plate is attached to the side casing with a cable J us Intertek Intertek WN 16399 ETL 4001507 TOWN amp COUNTRY FIREPLACES MODELE TCWS54 VENTED GAS FIREPLACE NOT FOR USE WITH SOLID FUEL FOYER AU GAZ A EVACUATION NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE ANSI Z21 50b 2009 CSA 2 22b 2009 Vented Gas Fireplaces CAN CGA 2 17 M91 Gas Fired Appliance For Use At High Altitudes
45. ur for a couple of hours This is due to the curing of paints sealants and lubricants used inthe manufacturing process This condition is temporary Open doors and windows to ventilate area Smoke and fumes caused by the curing process may cause discomfort to some individuals Do not use the fireplace if any part has been under water Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water Due to high temperatures this gas appliance should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Clothing or other flammable material should not be placed on or near the appliance Any grill panel or door removed for servicing the unit must be replaced prior to operating Failure to do so may create a hazardous condition Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept
46. ving one of the two small access panels Fig 23B The wires from inside the outlet box are connected to the 110 V AC supply Fig 23C 6 Connect the gas supply to the valve Fig 19 HEAT SHIELD 7 Plug the A C adaptor into the outlet Fig 23 8 Attach the electrical box for the supplied wall control to the framing in the desired location up to 50 ft away 25 ft is supplied with fireplace An additional 25 ft can be achieved by using the optional kit Part 5005 064 available from your Fig 23A dealer WARNING The control box heat shield and access panel must be replaced Failure to do so will overheat and cause premature failure of the control OUTLET A CADAPTER GAS CONNECTION gt TOWN a COUNTRY TCWS 54CE3 2 0313 44 LUXURY FIREPLACES 14 9 Route the communication cable as required to the wall control electrical box 10 Attach the communication cable to the wall control Fig 24 11 Insert the 4 supplied AA batteries into the battery pack and connect to wall control Fig 25 DO NOT INSTALL BATTERIES IF FIREPLACE IS CONNECTED TO A POWER VENT 12 Fasten the wall switch to the electrical box 13 Fasten the faceplate to switch 14 If not already installed install the burner and media set using the instructions supplied with the burner kit 15 Turn on the gas supply and check that all connections are tight and leak free 16 Turn on gas and electrical supplies 1
47. ymbol Fig 56 will be displayed when the thermostat button is pressed To activate a set point temperature 1 Press the thermostat button to activate the thermostat mode The temperature and thermostat symbols will appear 2 Press and hold the thermostat button on the lower right hand side of the hand held remote for 5 seconds Fig 57 The temperature icon on the display will flash Fig 58 3 While the temperature icon is flashing use the up and down arrows to set the temperature to the desired setting 4 Once the desired setting is reached press the OK button If the OK button is not pressed the icon will continue to flash for 5 seconds and then set itself to the temperature displayed 5 Thefireplaceisnowinthermostatic mode To exit the thermostatic mode press the program manual or timer buttons Please note that the first press of the manual button will turn the fireplace off Fig 58 THERMOSTATIC BUTTON TEMPERATURE SETTING gt TOWN COUNTRY lt LUXURY FIREPLACES 31 APPENDIX CAUTION Turn off gas and electrical power supply if applicable and allow ample time for unit to cool before servicing appliance It is recommended that the fireplace and its venting should be inspected at least once a year by a qualified service person Glass Panel Warning Do not operate fireplace with glass panel removed cracked or broken Replace ment of the glass panel should be done