1. 866 701 0041 120 VAC Wiring Legend G Ground EP L1 White Ld LoudMouth L2 Black M LoudMouth 240 VAC Wiring Legend G Ground EF L1 Blue LT L2 Black M Use minimum 18 gauge wire to make short jumper wires Schematic showing how to connect two Schematic showing how to connect three heating heating mats or cables to the LoudMouth for mats or cables to the LoudMouth for monitoring monitoring during installation during installation Call Premier Underfloor Heating at 866 701 0040 if damage or problems occur Refer also to the installation manual or installation guidelines specific to the heating product being installed for additional instructions Premier Underfloor Heating Phone 866 701 0040 Fax 866 701 0041 Copyright 2006 2009 Premier Underfloor Heating Premier LoudMouth Instructions LIT PREMLMINSTO709 Effective 07 21 2009
2. LoudMoutn Operatin Instructions 9 volt battery PREPARATION 1 Open the battery compartment cover and connect the 9 volt battery included 2 Replace the battery compartment cover and switch the unit ON 3 The alarm should sound and the red light should be lit when there are no connec tions to a mat or cable If these things do not occur inspect the battery connec tion or replace the battery 4 During normal use the green light indicates that the LoudMouth is monitoring the mat or cable for damage Should the green light go out replace the battery before continuing work OPERATION Make sure the mats and or cables to be monitored are not connected to a power source The LoudMouth is designed to monitor the mats or cables individually However by making a temporary series con nection of multiple mats or cables it can monitor up to three products at one time 1 FOR A SINGLE MAT OR CABLE Insert each lead wire from the mat or cable into the L1 and L2 terminals no polarity with the ground wire inserted into the G ter minal Tighten the terminal screws onto the wires FOR UP TO THREE MATS OR CABLES Connect one Connect the leads to the LoudMouth Swith the unit ON The green light non green lead wire from one mat or cable into the L1 should be lit terminal Connect one non green lead wire from a DIFFERENT mat or cable into the L2 terminal Now 6 Press the TEST button to simulate a
3. damage condition connect the remaining lead wires so that the mats or before beginning work and anytime during installation if cables are in series with one another If this is not done desired to confirm LoudMouth operation properly the LoudMouth may not correctly monitor the mats Lastly connect all ground wires from the mats or cables together to the G terminal using a jumper wire See schematics on reverse side Call Premier Underfloor Heating at 866 701 0040 if damage or problems occur Refer to the heating product installation manual for detailed installation instruction for proper connection to the LoudMouth NOTE The LoudMouth is designed to assist in electrically monitoring Premier Underfloor Heating electric floor warming products for potential damage during prod 2 Set the switch to the ON position uct installation and floor covering installation Premier Underfloor Heating in no way ensures that the potential damage will be found by the LoudMouth and is not liable 3 A green light indicates the LoudMouth is operating for damage or location repair labor or any other costs associated with damage that is found or not found by the LoudMouth 4 Hang or place the LoudMouth where it can be seen and heard during heating product installation Premier 5 A red light and alarm indicate lead wires have come loose aA Bea from terminals or damage has occurred to the heating product Phone 866 701 0040 Fax

Download Pdf Manuals

image

Related Search

Related Contents

Manual de Instruções de Consulta à AMEDINAL  WebSphere Application Server Enterprise Edition 4.0  Manuale d`uso delle ruote Alcoa  Samsung SGH-L878E 用户手册  Pour le lire cliquez ici  Guide « L`éCO-ROuTE - Conseil Général du Bas-Rhin  Manuale programmazione  HP Mobile Thin Client 4320t Mobile Thin Client  Samsung HT-D330K Manual de Usuario  HYDRO C PROTECTOR PULPAR RADIOPACO A BASE  

Copyright © All rights reserved.
Failed to retrieve file