Home
Broan Elite EC62 Series Installation Manual (21240 rev.01).indd
Contents
1. 18 CONNECT WIRING ALL MODELS A WARNING Risk of electric shock Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally Position the power pack below the installed custom hood Insert the house wiring cable through the wire clamp previously installed in step 9 Tighten the wire clamp to secure the cable Connect cable using provided wire connectors Connect wires as follows BLACK to BLACK WHITE to WHITE and GREEN or BARE wire under ground screw DO NOT FORGET TO CONNECT THE GROUND 10 19 REINSTALL FILTERS CAUTION Remove protective plastic film covering filters before installing them 1 Using a Phillips no 2 screwdriver assemble the knob to each filter NOTE The screw MUST BE on filter tabs side See illustration at right 2 Rest rear filters edge on filter springs B in the power pack 3 Using knob tilt up the filters into position Make sure filter tabs C are securely engaged in power pack front edge after installation HD0373 20 LED LIGHTING The lighting of this hood is produced by two LED modules included A WARNING Do not touch lamps during or soon after operation Burns may occur Cannot be replaced by any other type of light bulb or LED module 21 USE AND CARE Filters
2. 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS IF THE FLAMES DO NOT GO OUT IMMEDIATELY EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels This could cause a violent steam explosion 4 Use an extinguisher ONLY if A You own a Class ABC extinguisher and you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION 1 For indoor use only 2 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 4 Your power pack motor s has a thermal overload which will automatically shut off the motor s if it overheats The motor s will restart when cooled down If the motor s continues to shut off and restart have the power pack serviced 5 The minimum hood distance above cooktop must not be less than 24 A maximum of 30 above cooktop is highly recommended for best capture of cooking impurities For a gas range the bottom of the hood MUST NOT BE LESS than 30 above cooktop 6 Two ins
3. 12 23 WIRING DIAGRAM BLK LINE NEUTRAL O 1 WHT GROUND E 120 VAC TRANSFORMER COLOR CODE BLACK BLUE BROWN GREY ORANGE RED 120 V Line WHITE YELLOW K1 nc K2 Nc K3 Nc BLOWER MOTOR K1 K2 No K3 No K4 No t ede OPTIONAL SECOND 3 1 BLOWER MOTOR 1 EA rr rr rr BLK 0162 BLK 24 WARRANTY ONE YEAR LIMITED WARRANTY FOR BROAN ELITE PRODUCTS Broan NuTone Canada Broan NuTone warrants to the original consumer purchaser of Broan Elite products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase LED modules and LED driver are also covered by this warranty for a period of one 1 year THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND INCANDESCENT BULBS FUSE FILTERS DUCTS ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to m
4. THE ADAPTER DAMPER ON BACK OF POWER PACK SINGLE BLOWER MODEL HORIZONTAL DISCHARGE ONLY From the outside of the wall using two no 8 x 3 8 Screws provided in parts bag secure the adapter damper to the back of the power pack Remove tape from damper flap Connect ducting to the adapter damper and seal the joint using metal foil duct tape HH0127A BACK VIEW SIDE VIEW The single blower power pack is factory shipped for a vertical F A u discharge installation For a horizontal discharge installation b AZE the blower must be flipped Using a 5 16 socket or a Phillips or 220075 7 RIGHT SIDE MOUNTING 12 77 t Robertson no 2 screwdriver secure the blower to the inner back 254107 74 SCREWS LOCATION of the power pack with all blower mounting screws previously removed in step 13 17 REINSTALL FRONT PANEL AND WIRING COVER CAUTION Take care not to pinch wiring when reinstalling the front panel and the wiring cover Carefully reassemble the front panel to the power pack by aligning the tabs with their corresponding slot Using a Robertson or a Phillips no 2 screwdriver secure the front panel to the power pack using its both retaining screws A previously removed in step 8 Reassemble the wiring cover using its both retaining screws B previously removed in step 8 Plug the motor s one or two depending on model to the front panel
5. Technical Support phone number listed on front cover To install see instruction packed with custom hood liner NOTE The liner must be installed before the insert NORMAL WIDTH 620085 624255 idth 30 nominal wid 0067 9 CUT THE HOLE IN CUSTOM HOOD BASE If it is not done yet cut a hole in the bottom of the custom hood using the dimensions shown at right NOTE Keep in mind that the unit exterior flange is 3 4 6 REMOVE FILTER Rest the power pack on a table Remove tapes on filters Lift filters from power pack by pushing e them towards the back and rotate then set filters aside 7 UNPLUG THE BLOWER S Unplug the blower s one or two depending on model from the front panel 8 REMOVE WIRING COVER AND FRONT PANEL Using a Robertson or a Phillips no 2 screwdriver remove both wiring cover retaining screws A Detach it from the power pack and set aside with its screws Then remove both sides screws B retaining the front panel to the power pack Carefully detach the front panel from the power pack and set aside with its screws 9 REMOVE THE ELECTRICAL KNOCKOUT From inside the power pack punch out the electrical knockout hole on top right side C OR on back right side D Install the wire clamp included in parts bag Remove the knockout opening on top vertical discharge installation or on back horizontal discharge instal
6. The filters should be cleaned frequently Use a warm detergent solution Wash more often if your cooking style generates more grease like frying foods or wok cooking Remove filter by pushing it towards the back of power pack and rotating filter downward Filters are dishwasher safe Allow filters to dry completely before reinstalling them in the power pack Clean all metal filters in the dishwasher using a non phosphate detergent Discoloration of the filters may occur if using phosphate de tergent or as a result of local water conditions but this will not affect filter performance This discoloration is not covered by the warranty Blower s Cleaning Remove the filters in order to access the blower s Use a shop vacuum to clean the blower s Do not immerse in water 11 21 USE AND CARE CONT D Power Pack Cleaning Stainless steel cleaning Do Don t Regularly wash with clean cloth or rag soaked with warm water Use any steel or stainless steel wool or any other scrapers to and mild soap or liquid dish detergent remove stubborn dirt Always clean in the direction of original polish lines Use any harsh or abrasive cleansers Always rinse well with clear water 2 or 3 times after cleaning Allow dirt to accumulate Wipe dry completely Let plaster dust or any other construction residues reach the You may also use a specialized household stainless steel power pack During construction or renovation cover the power clea
7. INSTALLATION INSTRUCTIONS BRGAN ze HB0091 EC62 SERIES A INTENDED FOR DOMESTIC COOKING ONLY A READ AND SAVE THESE INSTRUCTIONS INSTALLER LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 11 amp 12 Broan NuTone Canada ULC Mississauga Ontario www broan ca 1 877 896 1119 REGISTER YOUR PRODUCT ONLINE AT www broan ca 7 72371 3300 1 6 21240 Rev 01 ANWARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturers guidelines and safety standards such as those published by the Na
8. TER SUPPLIED AIT 1000 CFM DUAL BLOWER POWER PACK L6230SS L6236SS on L6242SS Custom Hoop LINER OPTIONAL EC6230TSSL POWER PACK Duat BLowER 1000 SUPPLIED WITH POWER PACK 1 PREPARE THE INSTALLATION A WARNING When performing installation servicing or cleaning the unit it is recommended to wear safety glasses and gloves NOTE Before proceeding to the installation check the contents of the box If items are missing or damaged contact the manufacturer Make sure that the following items are included Power Pack Accessories 2 Filters 2 Filter knobs with screws taped inside power pack 34 x 10 adapter damper supplied with 600 CFM single blower power pack 10 round in line vertical damper supplied with 1000 CFM dual blower power pack 10 round adapter supplied with 1000 CFM dual blower power pack Bag of parts including 1 wire clamp 2 wire connectors 4 no 8 x 3 8 screws 9 no 8 x 1 2 chrome plated screws 10 no 8 32 x 1 4 screws If need be discard extra hardware Parts sold separately Custom hood liner model L6230SS L6236SS or L6242SS optional Ducts elbows wall and roof caps Refer to page 3 for a complete list of venting options and model numbers NOTE During installation protect countertop and or cooktop 2 INSTALL DUCTWORK AND ELECTRICAL WIRING Plan where and how the ductwork will be installed Access to the top of the power pack is preferred for c
9. e chosen switch will light To turn off the blower press once more on the corresponding blower speed switch the switch light will shut off NOTE When blower is off pressing on blower speed 1 switch will cause the blower to start on high speed for a very short lapse of time and then resume on speed 1 C Master OFF FiLrER MAINTENANCE HEAT SENTRY TRIPLE FUNCTION Switch i To turn off the blower s and the light simultaneously press this switch once ii After 25 hours of operation this switch will light to indicate the filters and the blower wheel s need to be cleaned in order to maintain efficient operation of the unit The switch light will stay on until the function is reset by pressing this switch for 3 seconds iii The light indicator is used for the Heat Sentry function as well Heat Sentry The power pack is equipped with a protective device that activates when excessive heat is detected inside the power pack and when itis set on speed 4 This device takes control of the blower and deactivates speed 4 for a 10 minute period and sets it on speed 3 During the Heat Sentry activation only speed 3 can be used the Heat Sentry button will flash while the speed 3 button will light The power pack can also be turned OFF D Light Switcu This switch allows two different lighting levels according to your needs Press once for full intensity twice for nightlight To shut off the lights without turning off the blower press once more
10. eaks HJ0036A 13 REMOVE THE BLOWER SINGLE BLOWER MODEL HORIZONTAL DISCHARGE ONLY In order to ease the power pack alignment with horizontal ductwork disassemble the blower from the power pack before installing it in the custom hood 2 LEFT SIDE MOUNTING RiGHT SIDE MOUNTING SCREWS LOCATION SCREWS LOCATION Using a 5 16 socket or a Phillips no 2 or a Robertson no 2 screwdriver remove all blower mounting screws from the inner top of the power pack Set blower and screws aside 14 INSTALL THE POWER PACK CAUTION Take care not to kink ducting or pinch electrical cable when installing the power pack LASPING SPRINGS Insert the power pack in the custom hood until the bottom of the clasping springs 2 per side rests on the top of the custom hood base grey zone in illustration at right 14 INSTALL POWER PACK CONT D From inside the power pack using provided no 8 10 x 1 2 screws mount the power pack to the custom hood base To do so raise the front until its flange rests on the outer side of the custom hood base and use 2 screws to secure in place Do the same for the back then complete the installation with 2 additional screws on the front and back See figure at right for mounting screws locations VERTICAL ExHAusr INSTALLATION ONLY Ensure the adapter damper enters the ducting and the damper opens freely Wherever it is possible seal connections with metal foil duct tape 15 INSTALL
11. is warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone at the address or telephone number stated below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Broan NuTone Canada ULC 1140 Tristar Drive Mississauga ON L5T 1H9 www broan ca 1 877 896 1119 29 SERVICE PARTS EC6230SSL HL0234 Key No PART No 1 SV13296 ApaPrER DaMPER 314 X 10 SV08541 ApaPTER 10 RouND 62248 LED Driver AND CONNECTION HARNESS EC6230TSSL DESCRIPTION 21244 ELECTRONIC CoNTROL WiTH CHROMED Burrows AND BLuE LEDs 4 SCREWS NO 8 X 3 8 9 CHROMED PLATED SCREWS NO 8 10 X 1 27 10 MECHANICAL SCREWS NO 8 32 X 1 4 SV08545 PARTS BAG 2 WIRE CONNECTORS 1 WIRE CLAMP Not shown REPLACEMENT Parts AND REPAIRS In order to ensure your unit remains in good working condition you must use Broan NuTone genuine replacement parts only Broan NuTone genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety Any third party replacement part used may cause serious damage and drastically reduce the performance leve
12. isuse negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommended installation instructions Warranty service is to be completed by an authorized Service Center designated by Broan NuTone Where applicable in home service will be made available only in areas where a contracted service provider offers service If in home service is not available the product will be repaired or replaced at Broan NuTone s discretion by the nearest authorized service provider The unit removal and reinstallation works are under the customer responsibility and Broan NuTone cannot be charged for them The duration of any implied warranty is limited to the one year period as specified for the express warranty Some provinces do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from province to another Th
13. l of your unit which will result in premature failing Broan NuTone recommends to contact a certified service depot for all replacement parts and repairs 14
14. lation of the power pack VERTICAL DISCHARGE INSTALLATION Using 2 no 8 x 3 8 screws provided in parts bag secure the adapter damper to the top of the power pack Remove tape from damper flap Seal the adapter to the power pack using metal foil duct tape HORIZONTAL DISCHARGE INSTALLATION The adapter damper will be installed on the back of the power pack once the power pack is mounted in the custom hood Refer to step 15 12 INSTALL THE ADAPTER AND THE DAMPER DUAL BLOWER MODEL ONLY MOUNTING SCREWS LOCATION ee Using 2 no 8 x 3 8 screws from parts bag assemble the adapter on the top of the power pack 55 Seal all joints with metal foil duct tape to eliminate air leaks 12 INSTALL THE ADAPTER AND THE DAMPER DUAL BLOWER MODEL ONLY CONT D DAMPER HINGE Install 10 damper inside the VERTICAL ductwork that will be attached to power pack Do not install Gra in a horizontal ductwork or it will not open and close properly Remove shipping tape if present To optimize airflow and reduce noise position the damper at least 17 above the top of the double blower power pack or as far as the duct run will allow Also ensure the damper hinge will be parallel to power pack sides see figure at right Secure the damper to the duct with 3 no 8 sheet metal screws not provided Ensure damper opens and closes freely Seal all joints with metal foil duct tape to eliminate air l
15. ner pack to make sure no dust adheres to stainless steel surface Avoid when choosing a detergent Anycleaners that contain bleach will attack stainless steel Any products containing chloride fluoride iodide bromide will deteriorate surfaces rapidly Any combustible products used for cleaning such as acetone alcohol ether benzol etc are highly explosive and should never be used close to a range 22 OPERATION A WARNING When using a gas stove always turn the power pack blower s on prior to begin cooking In addition the blower s must be at least in third speed if three burners or more are turned on simultaneously Failure to do so may lead the surface of the power pack to become very hot Always turn your power pack on before you begin cooking to establish an air flow in the kitchen Let the blower run for a few minutes to clear the air after you turn off the range This will help keep the whole kitchen cleaner and brighter HC0023 A A DELAY SWITCH When a blower speed is selected press this switch to activate the delay function The corresponding blower speed switch will flash to indicate this function is activated The blower will continue to operate for 5 minutes and will stop automatically To cancel the delay function press the delay switch once again B Start Stop SPEED SELECTION SWITCHES Press the switch corresponding to the desired blower speed from 1 for low speed to 4 for high speed Th
16. onnection of ductwork Install proper sized ductwork elbows and roof or wall cap for the type of power pack you are installing If installing EC6230SSL single blower power pack use 3 x 10 ductwork If installing EC6230TSSL double blower power pack use 10 round ductwork Use 2 metal foil duct tape to seal duct joints We recommend to install the power pack at a minimum distance of 24 from an electric range and 30 from a gas range Distances over 30 are at the installer and users discretion Run 3 wire power supply cable to installation location Its length should extend at least 4 feet below the bottom of the custom hood Roof cap Ga e 10 round duct 122 10 in line V vertical damper img 5 10 round elbow a 3 x 10 10 round adapter adapter amp damper b Power pack E Power pack 24 minimum above 24 minimum above cooking surface cooking surface 30 for gas range 30 for gas range EC6230SSL EC6230TSSL SINGLE BLOWER Ductwork DUAL BLOWER TyPicaL Ductwork NOTE Although the horizontal discharge installation is feasible with EC6230SSL power pack model this installation type should be performed in specific situation only since it requires particular knowledge and technical skills from the installers 3 PREPARE CUSTOM HOOD A WARNING When building a custom hood always follow all applicable construction codes and standards The custom hood must be p
17. ositively secured to wall studs or other wooden framework behind the drywall Make sure it is capable of supporting its own weight and the weight of the power pack Failure to do so may cause personal injury or damage to countertop or cooktop The custom hood must be constructed to fit the shape and total weight of the EC62 power pack model The recommended minimum thickness for the custom hood base is 5 8 If an optional custom hood liner will be installed we recommend the sides and front of the custom hood to be 3 4 thick If the optional custom hood liner will not be installed the custom hood sides and front thickness are at the installer s discretion See chart and illustration for details Blower Power Pack TOP VIEW 10 1546 Ae HKO104A BACK VIEW DuaL BLower Power Pack NOTE The dual blower model has the same dimensions as the single blower model but does not have a horizontal discharge Refer to single blower power pack illustration for back and side views and disregard horizontal discharge measurements HKO114A TOP VIEW 4 INSTALL CUSTOM HOOD LINER OPTIONAL The liners are especially designed to protect the exterior base of the custom hood Refer to the table below to find the right liner model number according to the width of the custom hood nominal width To view specific model information including depths for each liner model visit www broan ca or contact
18. tallers are recommended because of the large size and weight of this unit To reduce the risk of fire and to properly exhaust air be sure to duct air outside Do not exhaust air into spaces within walls or ceiling or into attics crawl space or garage 8 Because of the high exhausting capacity of this unit you should make sure enough air is entering the house to replace exhausted air by opening a window close to or in the kitchen 9 To reduce the risk of fire and electrical shock the Broan Elite EC62 Series models must be installed only with their own built in blower s Other blowers cannot be substituted 10 Please read specification label on product for further information and requirements EC62 SERIES POWER PACK SYSTEM STANDARD 3 x 10 WaLL Nor INCLUDED STANDARD 3 x 10 Roor Cap Nor INCLUDED STANDARD 3 x 10 Duct Nor INCLUDED 3 x 10 ApaPTER DAMPER SUPPLIED WITH SINGLE BLOWER POWER PACK EC6230SSL POWER PACK HLO126 SINGLE BLowER 600 crm SUPPLIED WITH POWER PACK 441 10 MA Nor INCLUDED 437 HicH CaPacirv Roor Nor INCLUDED 418 10 Round ADJUSTABLE ELBOW Nor INCLUDED 410 10 Rounp Duct 2 FT SECTIONS Nor INCLUDED 10 RouNp VERTICAL IN LinE DAMPER SUPPLIED wrrH 1000 DUAL BLOWER POWER PACK 10 Rounp ADAP
19. tional Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented outdoors 7 To reduce the risk of fire or electric shock do not use this unit with any additional solid state speed control device 8 To reduce the risk of fire use only metal ductwork 9 This unit must be grounded 10 When applicable local regulations comprise more restrictive installation and or certification requirements the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses TO REDUCETHE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when flambeing food i e Cr pes Suzette Cherries Jubilee Peppercorn Beef Flamb c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan filters or in exhaust ducts d Use proper pan size Always use cookware appropriate for the size of the surface element ZS WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING
Download Pdf Manuals
Related Search
Related Contents
Philips Voice Tracer digital recorder DVT5000 R7FN 取扱説明書 少点数入出力ユニット - M Sony CMT-EP303 User's Manual Lago 0321 Regolatore riscaldamento MENU PROGRAMMING by KEYPAD APEX Serie Probensammelpumpen Benutzerhandbuch PROGRAMME DE TRAVAIL DE LA MTS 2013 -2017 Icecrypt STC6000HD PVR - TELE Manual de instalação DVIP 1000 - 231.29 KB Copyright © All rights reserved.