Home

Remote Power Supply Unit Installation Manual

image

Contents

1. 24 hours or When mains fail Battery pack damaged If the unit still doesn t work after checking these possible causes contact Thomas amp Betts Service in Australia on 1300 666 595 Monday to Friday 8 30am to 4 30pm AEST and ask for help Our trained service personnel will usually be able to take your call immediately and assist you in resolving your difficulty Thomas amp Betts is committed to providing valuable Through Life Support for its products Red LED is lit only applicable where used but lamp doesn t come on when test switch is pressed Copyright 2013 Thomas amp Betts Australasia ABN 062 074 810 898 Rev 3 0 26 July 2013 4 Complete Solutions in Emergency Lighting Doc No 29 01072 Thomas 8etts A Member of the ABB Group Thomas amp Betts Australasia ABN 062 074 810 898 Head Office Unit D3 3 29 Birnie Avenue Lidcombe NSW 2141 Australia Manufacturing 23a Nyrang Street Lidcombe NSW 2141 Australia Telephone 61 1300 666 595 Facsimile 61 1300 666 594 Remote Power Supply Unit Installation Manual tem Electrical Safety Warning Installation Instructions Wiring Connections Removal Method Trouble Shooting Guide Warranty Information Included GREETINGS Congratulations on choosing to use this Thomas amp Betts product covered by our unique Through Life Support system This document is designed to assist you during the installation of the product to ensure the safety of
2. yourself and others The Remote Power Supply Unit is designed to be installed quickly and easily however Thomas amp Betts recommends that you read this document thoroughly before commencing installation This device has been manufactured to provide trouble free operation for many years when treated with due care and maintained through regular and appropriate servicing SAFETY WARNING In Australia and New Zealand only licensed electricians are permitted by law to work with 240 Volt electrical installations Do not attempt to install or connect this product unless you are a licensed electrician Turn off and isolate the electrical supply before connecting this fitting to the building wires Do not touch the terminals of the terminal block when the light fitting is energised The only user serviceable parts are the lamp and battery pack Do not tamper with the fitting or the warranty will be void As the installer it is your responsibility to ensure compliance with all relevant building and safety codes ie AS3000 AS NZS2293 Refer to the applicable standards for data and mains cabling installation procedures and requirements Copyright 2013 Thomas amp Betts Australasia ABN 062 074 810 898 Rev 3 0 26 July 2013 1 Complete Solutions in Emergency Lighting INSTALLATION INSTRUCTIONS To install the emergency backup power supplies follow these steps STANILITE 1 Remove the unit from the packing box and inspect it fo
3. STANILITE STANILITE Complete Solutions in Emergency Lighting PS702M 12V maintained unit designed to be used remotely to provide escape lighting for large areas or to provide backup supply for the lighting up of difficult or hostile environments The maximum load limit is 35W if used in a lift The maximum load can be 70W if using as backup supply to comply with AS NZS2293 Output to load max 70W Mains 240Vac 50Hz For switched illumination Connect incoming switched active unswitched active neutral and earth to terminal marked S A A N and E respectively For permanent illumination Connect incoming unswitched active neutral and earth to terminal marked A N and E respectively Note Loop link between S A and A Battery 6 Lamp operation Maintained Once powered up in a maintained fitting the normal AC lamp if present should light up and stay on until the power supply to the unit fails The emergency function of the unit should only operate when the unswitched active power supply fails or when somebody presses the manual test button located on the fitting Non maintained Once powered up in a non maintained fitting the present lamp stays off The emergency function of the unit should only operate when the unswitched active power supply fails or when somebody presses the manual test button located on the fitting TO REMOVE INSTALLED UNIT Switch off the mains supplies to the unit Remove the fuse from fuse ho
4. lder and then unscrew the mounting screws of the unit When the unit is reconnected to the supply it will need time to recharge its battery before it will be capable of a full length discharge again CONSTRUCTION SITES Continuously switching on and off the mains supply to the fittings during the installation process due to building works or for some other reason could cause the fittings to discharge and charge their batteries many times over a short period which may shorten the life of the battery Thomas amp Betts does not recommend such practices and may not honour any warranty on the life of the batteries or the lamp when subjected to such harsh operating conditions In order to prevent damage to the battery leave the unswitched active circuit turned off at the circuit breaker until the emergency lighting is required on the site TROUBLE SHOOTING GUIDE If you ve installed and connected the unit as per the instructions listed earlier and it doesn t work properly use the following table as a guide to fixing the problem Look up the type of fault in the left column and check the possible causes from the right column 1 Red LED not lit AC supply not connected or only applicable where used AC supply turned off or Battery not connected or Fuse missing or Test switch damaged Lamp damaged or Battery pack damaged or Test switch damaged 3 Lamp is lit momentarily when test switch is pressed or Battery not fully charged allow up to
5. ly to comply with AS NZS2293 PS404M 12V maintained unit specifically designed for lift to run 2x20 watt down lights PS702 NB 12V non maintained unit designed to be used remotely to provide escape lighting for large areas or to provide backup supply for the lighting up of difficult or hostile environments The maximum load limit is 35W if used in a lift The maximum load can be 70W if using as backup supply to comply with AS NZS2293 Output 12V DC Output to load max 40W run up to 4 hours Mains 240Vac 50Hz Connect incoming unswitched active neutral and earth to terminal marked US A N and E respectively 12V input from external transformer to run as a maintained unit _ a a Transformer Output to load max 40W run up to 4 hours Mains 240Vac 50Hz For switched illumination Connect incoming switched active unswitched active neutral and earth to terminal marked S A A N and E respectively For permanent illumination Connect incoming unswitched active neutral and earth to terminal marked A N and E respectively Note Loop link between S A and A Output to load max 70W Mains 240Vac 50Hz Connect incoming unswitched active neutral and earth to terminal marked US A N and E respectively 12V input from external transformer to run as a maintained unit Copyright 2013 Thomas amp Betts Australasia ABN 062 074 810 898 Rev 3 0 26 July 2013 3 STANILITE
6. r damage or imperfections If any damage is found do not install replace it carefully into the packing box and notify the Thomas amp Betts Product Support Hotline in Australia on 1300 666 595 2 Ifall looks okay proceed with the installation use a pencil to mark the position of the mounting screw holes for the unit O gt Depending on the wiring configuration determine the cable entry or exit and remove the appropriate cable knockout s 4 Secure the unit to the wall ceiling using appropriate fixings not supplied depending on the type of building construction material used WIRING CONNECTIONS 5 Following below are the wiring connections of various models of remote power supplies Ensure that the stripped wire ends are completely inserted into the terminal block and no bare conductors are exposed to the metal Place the fuse into fuse holder before connecting unit to mains fuse is placed inside the box and normally secure with the tape PS504 12V non maintained unit specifically designed for lift to run 2x50 watt down lights The output power on emergency is 50 of the rated power PS504M 12V maintained unit specifically designed for lift to run 2x50 watt down lights The output power on emergency is 50 of the rated power Battery PS124 12V non maintained unit designed for lift but can also be used remotely to provide escape lighting for large areas or to provide backup supply for the lighting up of difficult o
7. r hostile environments The maximum load limit is 12W if used in a lift The maximum load can be 24W if using as backup supply to comply with AS NZS2293 Bell Connection if used Output to Lamp 1 Output to Lamp 2 Mains 240Vac 50Hz Connect incoming unswitched active neutral and earth to terminal marked US A N and E respectively 12V input from external transformer to run as a maintained unit Bell Connection if used Output to Lamp 1 Output to Lamp 2 Mains 240Vac 50Hz For switched illumination Connect incoming switched active unswitched active neutral and earth to terminal marked S A A N and E respectively For permanent illumination Connect incoming unswitched active neutral and earth to terminal marked A N and E respectively Battery Note Loop link between S A and A Connect incoming unswitched active neutral and earth to terminal marked US A N and E respectively Bell Connection if used Output to load max 12W Mains 240Vac 50Hz Copyright 2013 Thomas amp Betts Australasia ABN 062 074 810 898 Rev 3 0 26 July 2013 2 Complete Solutions in Emergency Lighting PS404 NB 12V non maintained unit designed for lift but can also be used remotely to provide escape lighting for large areas or to provide backup supply for the lighting up of difficult or hostile environments The maximum load limit is 40W if used in a lift The maximum load can be 80W if using as backup supp

Download Pdf Manuals

image

Related Search

Related Contents

Belgafax™ 700 - Aide et support  TMS Web Operator Confirmation User Manual  Premier Mounts Universal Flat Mount for 37-63" Displays (XUF-3760)  Philips 46677229993 halogen lamp  Windows - Pronova  Windsor Installation & User Manual  2 - SCHOOLアプリ管理者画面  Metra 99-2001 mounting kit  MULTÍMETRO DIGITAL DIGITAL MULTIMETER ET-2053  Micro Innovations USB740R 2-Port Hi-Speed USB Cardbus  