CRO 4040-1 - Sapphire Water
Contents
1. Date Purchased Voltage Other Features Standard Auto Flush Permeate Flush 8 x 5 box size 8 x 6 8 x 10 10 x 12 Red Dot Blue Dot Yellow Dot No Dot Refers to the colored dot on the main computer chip in the Electrical Box 5700 Electrical Box 750 Electrical Box L Other Specific Problem Use a second sheet if needed SAPPHIRE WATER 105 1 Ave SW Watson SK SOK 4V0 Tel 306 287 3633 Toll Free 800 205 3633 Fax 306 287 3795 12 GENERAL OPERATION amp INSTALLATION MANUAL sap0060517 002 SAPPHIRE WATER CRO 4040 1 CRO 4040 5 Warranty SAPPHIRE warrants its equipment against defects in workmanship and materials for a period of one 1 year from date of purchase of equipment by the customer Such equipment must be used strictly in accordance with instructions furnished by manufacturer and for the purposes disclosed at the time of purchase Liability of the company shall be limited to the replacement or repair F O B Watson Saskatchewan Canada of any defective equipment or part which having been inspected by the manufacturer and determined in the company s sole judgment as requiring replacement or repair because of defects in original workmanship and or materials Should membrane material or workmanship prove faulty it will be covered by the watranty of the membrane manufacturer No other warranties are expressed or impli
2. 100 F Feed Water pH Range 3 0 10 0 Maximum Feed Water Turbidity 5 NTU Maximum Feed Water S D I 15 min 4 0 Feed water Chlorine Concentration lt 0 1 ppm Maximum Ratio of Concentrate to Permeate Flow 5 1 Mechanical Installation Pre treatment requirements vary A complete water analysis should be conducted before installation and pre treatment recommendations made by your SAPPHIRE dealer Note Chlorine must be removed prior to water reaching the RO system Mount system on the floor or a secure stand 1 Connect a ball valve 1 2 min to the inlet side of the pre filter Connect feed water line to the ball valve Provide piping from the concentrate outlet to drain Drain must be equipped with a P trap or air gap Do not install a shut off valve downstream of the Concentrate control valve Provide piping from the product outlet to the storage tank Product water should enter the storage tank in through the top of the tank An air gap should be provided from the water level to product outlet See Diagram Storage tank should have a liquid level control provided to operate the Reverse Osmosis unit When the control goes down with the water level 3 GENERAL OPERATION amp INSTALLATION MANUAL sap0060504 002 SAPPHIRE WATER CRO 4040 1 CRO 4040 5 it will turn the power to the RO unit on When the water level is up to the desired setting the liquid level switch will cut the power to the RO unit To Star
3. Specialties Controller Manual for Specific Settings on S 100 S 150 and the S 250 Manuals can be located on the R amp D website at rdspec ca under the tech support section Pick the manual that refers to your specific unit 5 GENERAL OPERATION amp INSTALLATION MANUAL sap0060517 002 SAPPHIRE WATER CRO 4040 1 CRO 4040 5 Reverse Osmosis Data Sheet DATE WATER TEMP FEED PRESSURE MEMBRANE PRESSURE PERMEATE FLOW CONCENTRATE FLOW 6 GENERAL OPERATION amp INSTALLATION MANUAL sap0060517 002 Typical Reverse Osmosis Installation SAPPHIRE WATER CRO 4040 1 CRO 4040 5 CRO 4040 1 Flow Chart PRODUCT WATER 1 FEED SUPPLY 8 CONCENTRATE VALVE 2 INLET SOLENOID VALVE 9 PRODUCT PERMEA TE WATER 3 BOOSTER PUMP 10 WASTE CONCENTRATE WA TE 4 MEMBRANE PRESSURE GAUGE 5 FEED WATER PRESSURE GA UGE 6 MEMBRANE AND HOUSING 7 WASTE WATER RECYCLE VALVE 8 GENERAL OPERATION amp INSTALLATION MANUAL sap0060517 002 SAPPHIRE WATER CRO 4040 1 CRO 4040 5 CRO 4040 2 Flow Chart aaa sann aaa PRODUCT WATER 1 FEED SUPPLY 8 CONCENTRATE VALVE 2 INLET SOLENOID VALVE 9 PRODUCT PERMEA TE WATER 3 BOOSTER PUMP 10 WASTE CONCEN
4. SAPPHIRE WATER CRO 4040 1 CRO 4040 5 Commercial Reverse Osmosis Units General Operation amp Installation Manual SAPPHIRE Commercial Reverse Osmosis Units If you need to call in for Technical support Please reference the following information for future reference Also please see the technical acquisition form at the back of this manual for further assistance Model Serial Date of Putchase Note The serial number is located in the front center of the RO panel SAPPHIRE WATER 105 1 Ave SW Watson SK SOK 4VO Phone 306 287 3633 Toll Free 800 205 3633 Fax 306 287 3795 SAPPHIRE WATER CRO 4040 1 CRO4040 5 General Operation and Specifications Congratulations for purchasing a SAPPHIRE Commercial Reverse Osmosis System This unit was specifically designed with you our customer in mind Top quality products and years of research and testing have gone into each SAPPHIRE unit to give you years of trouble free operation SAPPHIRE products include a whole family of water treatment equipment including softeners iron filters residential and commercial reverse osmosis equipment carbon sand and multi media filters and many more products SAPPHIRE CRO 4040 1 4040 5 units are floor mounted for ease of installation It is complete and ready for operation when the feed water supply and electrical connections are completed SEE CONTROLLER MANUAL Operation The SAPPHIRE Reverse Osm
5. TRATE WATER 4 MEMBRANE PRES SURE GAUGE 5 FEED WATER PRESSURE GAUGE 6 MEMBRANE AND HOUSING 7 WASTE WATER RECYCLE VALVE 9 GENERAL OPERATION amp INSTALLATION MANUAL sap0060517 002 SAPPHIRE WATER CRO 4040 1 CRO 4040 5 CRO 4040 3 Flow Chart 10 WASTE CONCENTRATE WATER 5 FEED WATER PRESSURE GAUGE 7 WASTE WATER RECYCLE VALVE 10 GENERAL OPERATION amp INSTALLATION MANUAL sap0060517 002 SAPPHIRE WATER CRO 4040 1 CRO 4040 5 CRO 4040 4 Flow Chart L H 8 CONCENTRATE VALVE LLL PRODUCT WATER 1 FEED SUPPLY 9 PRODUCT FLOWMETER 2 INLET SOLENOID VALVE 3 BOOSTER PUMP d 10 WASTE CONCENTRATE WATER 4 MEMBRANE PRESSURE GAUGE 5 FEED WATER PRESSURE GAUGE 6 MEMBRANE AND HOUSING IDEE CATRITDWUETER 7 WASTE WATER RECYCLE VALVE 11 AUTO FLUSH VALVE 11 GENERAL OPERATION amp INSTALLATION MANUAL sap0060517 002 SAPPHIRE WATER CRO 4040 1 CRO 4040 5 Technical Support TECHNICAL SUPPORT ACQUISITION Fax this form to your Dealer Technical Support Calls will be made ASAP Please Keep in mind any time Difference Please Print Clearly Date Company Name Contact Name Dealer Name Dealer Contact Phone Fax Model Serial
6. ed The purchaser is urged to keep accurate records of the operation of the unit This will serve to protect his her interests and greatly expedite replacement should it be required 13 GENERAL OPERATION amp INSTALLATION MANUAL sap0060517 002 14
7. low rate and pressure If you have your desired pressure but the concentrate flow is too high simply open the Recycle valve until the membrane pressure drops 10 psi Close the Concentrate valve until the concentrate flow drops to the desired setting or the membrane pressure rises 10 psi If the desired setting is still not achieved repeat the above steps until your unit is set Note It is recommended that the concentrate permeate ratio be 2 1 The ratio can be set down to 1 1 by your SAPPHIRE dealer only with permission from the factory Failure to comply with these ratios could void your warranty 4 Check entire system for leaks 4 GENERAL OPERATION amp INSTALLATION MANUAL sap0060517 002 SAPPHIRE WATER CRO 4040 1 CRO 4040 5 Maintenance 1 Check membrane pressure gauge regularly to see that the system pressure is operating according to factory specs 2 Itis good practice to Fast Flush the membrane s once per week by opening the Concentrate valve fully for 15 minutes to rinse built up scale and solids from the membrane surface 3 Itis good practice to log as much data as possible at least on a weekly basis e g feed pressure membrane pressure permeate flow concentrate flow feed water temp For your convenience an initial data log is included with this manual Troubleshooting Refer to the R amp D Manual that was included with your unit for the troubleshooting guide Refer to R amp D
8. osis system is fully automatic when used with a storage tank and level control see diagram The system requires little attention and maintenance The SAPPHIRE Reverse Osmosis system operates by the principle of reverse osmosis The feed water passes through a 5 micron pre filter which removes suspended particles larger than 5 microns in size The feed water is then fed into a booster pump that boosts the water pressure from the line pressure up to 150 to 200 psi The pressurized water enters the membrane s The membrane s separate the water into two streams product permeate and waste concentrate water The product water has passed through the membrane s leaving behind 99 of any attached ions The wastewater is a concentrated solution that carries the ions left behind by the product water When the wastewater leaves the membrane s a portion of it goes through a recycle valve and goes across the membrane s again The remaining wastewater goes through a concentrate valve and then to drain Some SAPPHIRE units are equipped with a recycle valve for maximum water savings If there is no recycle valve on a Reverse Osmosis unit the waste to product ratio would be 5 1 The recycle valve enables the ratio to be 1 1 2 GENERAL OPERATION amp INSTALLATION MANUAL sap0060504 002 SAPPHIRE WATER CRO 4040 1 CRO 4040 5 Specifications Maximum Applied Pressure 225 psi Normal Operating Pressure 150 200 psi Maximum Operating Temperature
9. t Unit Open the water supply valve to the unit Make sure that both the Recycle valve and Concentrate valve are fully open Proper electrical connections should be done Plug the unit in OFF should read on display If a float switch is being used proper connections should be done by connecting black and white wires to the wires marked tank full Unit will start and have three while purging delayed start This is a delayed start to allow water to get to the pump before pump start up Some units will show FLS and have a limited flush Note Units equipped with 2005 computer chip on the circuit board will w have a delayed start solenoid valve will open and unit will purge for 5seconds The Unit will then start and some units will display FLS Unit will flush for 5 minutes and run for 2 hours and flush again continuously No adjustments can be made regarding time on flush or run Units equipped with a 2004 chip Standard will purge for 5 seconds and show TDS reading three chips are available with permeate or auto flush boxes Refer to R amp D Specialties controller manual for flush modes or types 3 After the unit has run for at least 1 minute turn the Concentrate valve slowly clockwise until your concentrate flow rate is 2 1 with the permeate flow rate Then turn the Recycle valve slowly clockwise until the membrane pressure is at factory operating specs See chart These two valves adjust the f
Download Pdf Manuals
Related Search
Related Contents
CSRレポート2010 PDF形式データ (7.8MB) User`s Manual Template Philips BTM2310 User Guide Manual サニ太くん シリーズ NMP-1000 Network Multimedia Player User Manual (Version: 1.1.2) External Operational and Invoicing ConQuest User Guide Mode d`emploi Meule d`affûtage pour couteaux Samsung 23" SyncMaster SB550V LS23B550VS/EN Bruksanvisning Ericsson BS120 User's Manual Copyright © All rights reserved.