1. and the On Off and temperature settings will all disappear e To clear all weekly timer settings at once hold down the Check Clear button 10 for two seconds or more The display will begin blinking indicating that all settings have been cleared e Note Your new entries will be cancelled if you press the Mode Return button 2 before pressing the Filter button 4 If you have set two or more different operations for exactly the same time only the operation with the highest Operation No will be carried out 9 Repeat Steps 3 to 8 as necessary to fill as many of the available cells as you wish 10 Press the mode Return button 2 to return to the standard control screen and complete the setting procedure 11 To activate the timer press the Timer On Off button 9 so that the Timer Off indication disappears from the screen Be sure that the Timer Off indication is no longer displayed f there are no timer settings the Timer Off indication will blink on the screen Page 14 of 23 How to View the Weekly Timer Settings 8 D Timer Settings 1 Be sure that the weekly timer indicator is visible on the screen at 1 2 Press the Timer Menu button 12 so that Monitor is indicated on the screen at 8 3 Press the Timer On Off Set Day button 9 as necessary to select the day you wish to View 4 Press the W or A Operation button 7 or 8 as necessary to change the timer op
2. 5 Operation 5 1 Turning ON OFF Seanom COLI s Pi x 9 2 D 5 lt To Start Operation gt Press the ON OFF button The ON lamp 1 and the display area will light up or come on Note When the unit is restarted initial settings are as follows re Remote Controller settings Temperature setting Last set temperature lt To Stop Operation gt Press the ON OFF button again e The ON lamp 1 and the display area go off Page 9 of 23 5 2 Mode select Press the operation mode CI4 0120 button and select the operation mode displays in 2 above r Dryigmode 0Q mode T pamte o Automatic cooling heating mode Only heat pump type Ventilation mode Only indicated on Wired remote controller when LOSSNAY connected 5 3 Temperature setting To decrease the room temperature Press button 3 to set the desired temperature The selected temperature 1s displayed 3 To increase the room temperature Press button 3 to set the desired temperature The selected temperature 1s displayed 3 Available temperature ranges are as follows Cooling Drying 19 30 C 67 87 F Heating 17 28 C 63 83 F Automatic 19 28 C 67 83 F The display blinks either 8 C 39 C 46 F 102 F to inform you if the room temperature 1s lower or higher than the displayed temperature 5 4 Fan speed setting Pressing the Fan Speed button will display the follow
3. NOT AVAILABLE message The ZUBA Central has fixed speeds for Heating and Cooling Page 10 of 23 6 Timer 6 1 For Wired Remote controller You can use Function Selection of remote controller to select which of three types of timer to use 1 Weekly timer 2 Simple timer or 3 Auto Off timer 6 1 1 Weekly Timer The weekly timer can be used to set up to eight operations for each day of the week Each operation may consist of any of the following ON OFF time together with a temperature setting or ON OFF time only or Temperature setting only When the current time matches a set time point the timer performs the set operation Time setting resolution for this timer 1s one minute Note Weekly Timer Simple Timer Auto Off Timer cannot be used at the same time 2 The weekly timer will not operate when any of the following conditions are in effect e The timer feature is off The system is in a malfunction state Test run 1s in progress Remote controller is in self check mode or remote controller check the user is in the process of setting a function or setting the timer the user is in the process of setting the current day of the week or time System is under central control Specifically the system will not carry out operations unit on unit off or temperature setting during these conditions Page 11 of 23 Operation No Day Setting How to Set the Weekly Timer 1 Be sure that you are at
4. Ahead Timer On Off button Set Day button Check button Clear button Airflow Up Down button Louver button N7 Operation button To return operation Opening the 7 number u iig Ventilation button UN A Operation button LJ Built in temperature sensor CA To go to next opera tion number Note e PLEASE WAIT message This message is displayed for approximately 3 minutes when power is supplied to the indoor unit or when the unit is recovering from a power fail ure e NOT AVAILABLE message This message is displayed if a button is pressed to operate a function that the indoor unit does not have Page 5 of 23 How to use the Zuba Central controller Screen Configuration Function Selection of remote controller Set Day Time CHANGE TME SET 0 ya LAH CUATE 1H EHTER Standard Control Screens ACRCDOL E mF Bu Sell d o 38 1 BLN MON TUE WED THU FRI BAT 3n rn 0 00 Demo o o FID Ig Page 6 of 23 Screen Types For details on setting the language for the remote controller display refer to section 8 Function Selection The initial language setting 1s English Jaw Function Selection of remote controller Set the functions and ranges available to the remote controller timer functions operating restrictions etc Set Day Time Set the current day of the week or time Standard Control Screens View and set the air conditioning system s operating st
5. a standard control screen and that the weekly timer indicator 1 1s shown in the display 2 Press the Timer Menu button 12 so that the Set Up appears on the screen at 2 Note that each press of the button toggles the display between Set Up and Monitor 3 Press the Timer On Off Set Day button 9 to set the day Each press advances the display at 3 to the next setting in the following sequence Sun Mon Tues Wed Thurs Fri Sat gt Sun gt gt Fri gt Sat gt Sun Mon Tues Wed Thurs Fri Sat 4 Press the v or A Operation button 7 or 8 as necessary to select the appropriate operation number 1 to 8 4 Your inputs at Steps 3 and 4 will select one of the cells from the matrix illustrated below The remote controller display at left Shows how the display would appear when setting Operation 1 for Sunday to the values indicated below Page 12 of 23 Setup Matrix Monday Saturday Monday Noo 10 00 10 00 10 00 10 00 e OFF OFF OFF OFF oo LL LL Ooo So LLL NENNEN Ne8 SS Operation 1 settings for Sunday Operation 2 settings for every day Start the air conditioner at 8 30 with Turn off the air conditioner at 10 00 the temperature set to 73 F Note By setting the day to Sun Mon Tues Wed Thurs Fri Sat you can set the same operation to be carried out at the same time every day Example Operati
6. or fire may result e This system is NOT intended for use by children or infirm persons without supervision e Young children must be supervised to ensure that they do not play with the air conditioner e If the refrigeration gas blows out or leaks stop the operation of the system thoroughly ventilate the room and contact your dealer Caution e Do not use any sharp object to push the buttons as this may damage the remote controller e Never block or cover the indoor or outdoor unit s intakes or outlets Disposing of the unit e When you need to dispose of the unit consult your dealer Page 4 of 23 Zuba Central controller Display Section Displayed when the remote controller sensor is used For purposes of this explanation Day of Week all parts of the display are shown Shows the current day of the week During actual operation only the relevant items will be displayed Time Timer Display Shows the current time unless the simple or Auto Off Locked indicator Indicates that remote controller but tons have been locked Clean The Filter indicator Comes on when it is time to clean the filter timer is set If the simple or Auto Off timer is set shows the time re Identifies the current operation maining Shows the operating mode etc Multi language display is sup ported E MITSUBISHI ELECTRIC TIME SUN MON TUE WED THU FRI SAT TIMER 4 4 f I l1 Hr ON AFTER P 4
7. 2 hours 3 hours NIB At 5 hours after timer start DF EL BoF Fal The air conditioner comes on and will con i i g 389 4 suns tinue to run until it is turned off This timer begins countdown when the air conditioner starts and shuts the air conditioner off when the set time has elapsed Available settings run from 30 minutes to 4 hours in 30 minute intervals Note 1 Weekly Timer Simple Timer Auto off Timer cannot be used at the same time 2 The Auto Off timer will not operate when any of the following conditions is in effect The timer is off the system is in malfunction state a test run is in progress the remote controller is undergoing self check or remote controller check the user is in the process of selecting a function the user is in the process of setting the timer the system is under central control Under these conditions On Off operation is prohibited How to Set the Auto Off Timer 1 Be sure that you are at a standard control screen and that the Auto Off timer indicator is visible in the display at 1 When something other than the Auto Off Timer is displayed set it to AUTO OFF TIMER using the function selection of remote controller see 8 4 3 3 timer function setting 2 Hold down the Timer Menu button 12 for 3 seconds so that the Set Up appears on the screen at 2 Note that each press of the button toggles the display between Set Up and Monitor 3 Press the approp
8. I AFTER OFF Timer indicators ERROR CODE e OO FC i The esie pum on if the corre Centrally Controlled indicator j li 1FC E LINLI Fe a sponding timer is set Indicates that operation of the re VIINI Es mote controller has been prohibited by a master controller Fan Speed indicator Shows the selected fan speed Room Temperature display Up Down Air Direction indi Shows the room temperature The room Ventilation indicator cator temperature display range is 8 39 C The indi X h the di 46 102 F e indicator um The display blinks if the temperature is tion of the outcoming airflow less than 8 C 46 F or 39 C 102 F or more Timer is Off indicator Indicates that the timer is off Appears when the unit is running in Ventilation mode One Hour Only indicator Displayed if the airflow is set to Louver display Low and downward during COOL Indicates the action of the swing louver or DRY mode Operation varies Does not appear if the louver is station according to model The indicator goes off after one hour when the airflow direction also changes Temperature Setting Shows the target temperature Operation Section Set Temperature buttons CZ Down CA up Timer Menu button Monitor Set button ON OFF button Fan Speed button Filter 4 button Mode button Return button lt Enter gt button Test Run button Set Time buttons CZ Back CAD
9. The timer value will appear at 7 QOUL 700 3 Pirie A 4 Page 21 of 23 7 Error Codes indication play during operation with automatic mode aa MITSUBISHI ELECTRIC Ah mind E H3 Tn MIN OWN lamp Blinking Indoor Unit s Refriger Error Code Indoor Unit No ant Address Altemating Display If you have entered contact number to be called in the event of a problem the screen displays this number You can set this up under Function Selection of remote controller If the ON lamp and error code are both blinking This means that the system is out of order and operation has been stopped and cannot resume Take note of the indicated unit number and error code then switch off the power to the system and call your dealer or service provider s MITSUBISHI ELECTRIC CALL XXXX KARNAK a MITSUBISHI ELECTRIC OU u s 0 E j 3 1 ON OFF og Error Code D ON OFF oC If only the error code 1s blinking while the ON lamp remains lit Operation is continuing but there may be a problem with the system In this case you should note down the error code and then call your dealer or servicer for advice Note If you have entered contact number to be called in the event of a problem push the Check button to display it on the screen Page 22 of 23 User maintena
10. atus Timer Monitor View the currently set timer weekly timer simple timer or Auto Off timer Timer Setup Set the operation of any of the timers weekly timer simple timer or Auto Off timer How to change the screen Hold down both the Mode button and the Timer On Off button for 2 seconds Press the Timer Menu button Press the Mode Return button Press either of the Set Time buttons Back or Ahead To return to main screen Hold down both the Mode button and the Timer On Off button for 2 seconds Page 7 of 23 4 Setting the Day of the Week and Time Day of the Week amp Time display 3 Note The day and time will not appear if clock use has been disabled at Function Selection of remote controller HNN EN 3 Day of the Week Setting Time Set IO HENTER 7 7707 LI eee om a Press the Vor A Set Time button 11 to show display 2 2 Press the Timer On Off Set Day button 9 to set the day Each press advances the day shown at 3 sun gt Mon gt Fri gt Sat Press the appropriate Set Time button 11 as necessary to set the time As you hold the button down the time display at 4 will increment first in one minute intervals then 1n ten minute intervals and then 1n one hour intervals After making the appropriate settings at Steps 2 and 3 press the Filter button 4 to lock 1n the values Press the Mode button 2 to exit Page 8 of 23
11. eration shown on the display at 9 Each press will advance to the next timer operation in order of time setting 5 To close the monitor and return to the standard control screen press the Mode Return button 2 To Turn Off the Weekly Timer Press the Timer On Off button 9 so that Timer Off appears at 10 COOOL 238 rir H MES if e To Turn On the Weekly Timer Press the Timer On Off button 9 so that the Timer Off indication at 10 goes dark 6 1 2 Simple Timer You can set the simple timer in any of three ways e Start time only The air conditioner starts when the set time has elapsed e Stop time only The air conditioner stops when the set time has elapsed e Start amp stop times The air conditioner starts and stops at the respective elapsed times The simple timer start and stop can be set only once within a 72 hour period Page 15 of 23 The time setting is made in hour increments Note 1 Weekly Timer Simple Timer Auto Off Timer cannot be used at the same time 2 The simple timer will not operate when any of the following conditions is in effect The timer is off the system is in malfunction state a test run is in progress the remote controller is undergoing self check or remote controller check the user is in the process of selecting a function the user is in the process of setting the timer the system is under central control Under these conditions On Of
12. f operation is prohibited sa MITSUBISHI ELECTRIC TIMER ET EHTER cre fi TEMP D ON OFF 1 CA o CD Coo owENU gowo Pal JF nu T back wea Day Bea oe CAD PE di V OPERATION A CLEAR ai E 2 qb How to Set the Simple Timer Timer Setting TIMER SET Tw Vin Action On or Off JHSIEMTER 0 a un js displayed if there is no setting 1 Be sure that you are at a standard control screen and that the simple timer indicator is visible in the display at 1 When something other than the Simple Timer is displayed set it to SIMPLE TIMER using the function selection of remote controller see 8 3 3 timer function setting Page 16 of 23 2 Press the Timer Menu button 12 so that the Set Up appears on the screen at 2 Note that each press of the button toggles the display between Set Up and Monitor 3 Press the ON OFF button 1 to display the current ON or OFF simple timer setting Press the button once to display the time remaining to ON and then again to display the time remaining to OFF The ON OFF indication appears at 3 e ON timer The air conditioner will start operation when the specified number of hours has elapsed e OFF timer The air conditioner will stop operation when the specified number of specified number of hours has elapsed 4 With ON or OFF showing at 3 Press the appropriate Set Time button 11 as necessary to set the ho
13. nce Clean or replace filter monthly during heating and cooling season Replace the filter annually Caution Before you start cleaning stop operation and turn OFF the power supply Cleaning the filters Clean the filters using a vacuum cleaner If you do not have a vacuum cleaner tap the filters against a solid object to knock off dirt and dust Page 23 of 23
14. on 2 above which is the same for all days of the week Page 13 of 23 Setting the Weekly Timer Shows the time setting 6 shows the selected operation OM or OFF Does not appear if operation is not set Shows the temperature setting Does not appear if temperature is not set 5 Press the appropriate Set Time button 11 as necessary to set the desired time at 5 As you hold the button down the time first increments in minute intervals then in ten minute intervals and then 1n one hour intervals 6 Press the ON OFF button 1 to select the desired operation ON or OFF at 6 Each press changes the next setting 1n the following sequence No display no setting ON lt gt OFF 7 Press the appropriate Set Temperature button 3 to set the desired temperature at 7 Each press changes the setting in the following sequence No display no setting 75 lt gt 77 84 lt gt 87 53 lt gt 73 No display Available range The range for the setting is 12 C 53 F to 30 C 87 F The actual range over which the temperature can be controlled however will vary according to the type of the connected unit 8 After making the appropriate settings at Steps 5 6 and 7 press the Filter button 4 to lock in the values To clear the currently set values for the selected operation press and quickly release the Check Clear button 10 once e The displayed time setting will change to
15. ort to or obtain necessary permits from Local Electrical authority before connection to the system Symbols used in the text Warning Describes precautions that should be observed to prevent danger of injury or death to the user Caution Describes precautions that should be observed to prevent damage to the unit Page 3 of 23 Warnings e For appliances when installed should not be accessible to the general public e Theunit must not be installed by the user Ask the dealer or an authorized company to install the unit If the unit 1s installed improperly water leakage electric shock or fire may result e Do not stand on or place any items on the unit e Do not splash water over the unit and do not touch the unit with wet hands An electric shock may result e Do not spray combustible gas close to the unit Fire may result e Do not place a gas heater or any other open flame appliance where it will be exposed to the air discharged from the unit Incomplete combustion may result e Do not remove the front panel or the fan guard from the outdoor unit or the panels from the indoor unit when it 1s running e When you notice exceptionally abnormal noise or vibration stop operation turn off the power switch and contact your dealer Never insert fingers sticks etc into the intakes or outlets e If you detect odd smells stop using the unit turn off the power switch and consult your dealer Otherwise a breakdown electric shock
16. pe ff SII ELECTRIC Zuba Central Heat Pump User Manual Page 1 of 23 Introduction The Zuba Central is a Heat Pump using Hyper Heat technology The Zuba Central consists of outdoor unit and multi position ducted air handling indoor unit which are connected together and controlled by a PAR 211MAA controller Application Constant energy price increases in Canada and around the globe is increasing the consumer s requirements to source more efficient ways to cool and heat their homes The Zuba Central Hyper Heat Pump can save energy and reduce greenhouse gas emissions due to its high seasonal operation efficiency in both cooling and heating seasons In addition to this the new two phases liquid gas injection technology allows high heating output at ambient temperatures below 30 C The system is available with auxiliary back up heating options of hydronic hot water electrical resistance heat or SCR ducted heater Emergency Auxiliary back up heat 1s also activated in case of system malfunction Page 2 of 23 Contents Safety Precautions 3 Zuba Central controller PAR21MAA 5 Screen Configuration 6 Setting the Day of the Week and Time 8 Operation 9 Timer 11 Error Codes indication 22 User maintenance 23 Safety Precautions Before installing the unit make sure you read all the Safety Precautions The Safety Precautions provide very important points regarding safety Make sure you follow them Please rep
17. riate Set Time button 11 as necessary to set the OFF time at 3 Page 19 of 23 4 Press the Filter button 4 to lock in the setting Note Your entry will be cancelled if you press the Mode Return button 2 before pressing the Filter button 4 5 Press the Mode Return button 2 to complete the setting procedure and return to the standard control screen 6 If the air conditioner is already running the timer starts countdown immediately Be sure to check that the timer setting appears correctly on the display Checking the Current Auto Off Timer Setting Timer Setting 1 Be sure that the Auto Off is visible on the screen at 1 2 Hold down the Timer Menu button 12 for 3 seconds so that Monitor is indicated on the screen at 4 e The timer remaining to shutdown appears at 5 3 To close the monitor and return to the standard control screen press the Mode Return button 2 To Turn off the Auto off Timer Hold down the Timer On Off button 9 for 3 seconds so that Timer Off appears at 6 and the timer value at 7 disappears Alternatively turn off the air conditioner itself The timer value at 7 will disappear from the screen Page 20 of 23 To Turn On the Auto Off Timer Hold down the Timer On Off button 9 for 3 seconds The Timer Off indication disappears at 6 and the timer setting comes on the display at 7 Alternatively turn on the air conditioner
18. the Mode Return button 2 to close the monitor display and return to the standard control screen Page 17 of 23 To Turn Off the Simple Timer Press the Timer On Off button 9 so that the timer setting no longer appears on the screen at 7 To Turn On the Simple Timer Press the Timer On Off button 9 so that the timer setting becomes visible at 7 Examples When ON and OFF times have both been set at the simple timer then operation and display are as indicated below Example 1 Start the timer with ON time set earlier than OFF time ON Setting 3 hours OFF Setting 7 hours COOL rwy F BU Page 18 of 23 At Timer Start Display shows the timer s ON setting hours remaining to ON Display changes to show the timers OFF set ting hours remaining to OFF The time displayed is OFF setting 7 hours ON setting 3 hours 4 hours At 7 hours after timer start The air conditioner goes off and will remain off until it is restarted Example 2 Start the timer with OFF time set earlier than ON time ON Setting 5 hours OFF Setting 2 hours e BIB T mn on ESS At Timer Start p S 80 add j hour NE 1 T ae Display shows the timer s OFF setting hours e 5a remaining to OFF A At 2 hours after timer start J Display changes to show the timers ON set ting hours remaining to ON The time displayed is ON setting 5 hours OFF setting
19. urs to ON if ON is displayed or the hours to OFF if OFF is displayed at 4 Available Range 1 to 72 hours 5 To set both the ON and OFF times repeat Steps 3 and 4 Note that ON and OFF times cannot be set to the same value 6 To clear the current ON or OFF setting Display the ON or OFF setting see step 3 and then press the Check Clear button 10 so that the time setting clears to at 4 If you want to use only an ON setting or only an OFF setting be sure that the setting you do not wish to use is shown as 7 After completing steps 3 to 6 above press the Filter button 4 to lock in the value Note Your new settings will be cancelled if you press the Mode Return button before pressing the Filter 4 button 8 Press the Mode Return button 2 to return to the standard control screen 9 Press the Timer On Off button 9 to start the timer countdown When the timer is running the timer value is visible on the display Be sure that the timer value is visible and appropriate Viewing the Current Simple Timer Settings 6 Timer Setting msll ma mm 1 Be sure that the simple timer indicator is visible on the screen at 1 2 Press the Timer Menu button 9 so that the Monitor appears on the screen at 5 e f the ON or OFF simple timer is running the current timer value will appear at 6 e f ON and OFF values have both been set the two values appear alternately 3 Press