1. can also sound and electronic buzzer at the end of a printed receipt The POS 108 is ideal for restaurant kitchen or bar order printers and other service industries It uses the same RJ12 cash drawer port off the printer for its power The electronic buzzer is triggered by the cash drawer pulse function of the printer No cash drawer is required Two selectable options are available for the Printer Alarm Option 1 Alarm will sound for a selected amount of time 1 to 10 seconds when a receipt and then a drawer trigger option is printed This Alarm can be silenced by pressing the Push Button located on the top of the POS 108 See Figure 3 Another printer Alarm option is that an Alarm is sounded when a receipt and the drawer trigger option is printed This Alarm will stay on until the Push Button is pressed to silence the Alarm See Figure 4 for the Push Button Location Note that an External push button can be installed onto the POS108 if desired See Figure 5 and table 5 to find the location of the External Push Button connector inside the POS 108 This configuration is available on most IBM Star Epson Citizen and other compatible POS printers See Figure 2 for configuration Figure 2 POS108 connection illustration for Pinter Alarm to POS printer Compact and easy to mount these units are ideal for restaurants bars retail and other service industry applications Some of the features of POS108 include a dual RJ12 female connector status
2. in a Timing Loop INSTALLATION e Select Cash Drawer alarm or Printer Alarm using Dip switches 1 2 Table 1 e Select Time duration for the Selected Option Dip switches 2 3 Table 2 e Connect Cash Drawer only applies to Cash Drawer Alarm Option e Connect RJ12 to POS printer Cash Drawer port and power up Printer e Using Double sides adhesive Velcro mount POS108 where desired e Test Alarm function using your application software CONTENT INCLUDED 1 Pos 108 Device 2 Black Velcro double sided adhesive strip 3 CD Rom Manual WARRANTY 2 year limited warranty for parts and Labor Warranty is void if anyone other then the Manufacture s repair department or an authorized repair center services the POS 108 POS 108 USER MANUAL V2 1 Cash Drawer Alarm Until Drawer is closed Selectable modes Cash Drawer Alarm Until Drawer is closed or Max 1 Min On using Dip Switches Print Receipt Alarm Selectable 1 10 seconds On Print Receipt Alarm On until Push Button to Shut off rower Power from RJ12 cash drawer port on receipt printer current 10 100 mA typical current used by device only Drawer Connectors 2 x RJ12 Drawer 1 amp Drawer 2 80 x 45 x 28 5 mm WxDxH 150 gm RJ12 Cable Length 180 cm 6 Feet Humidity Temp 10 90 relative humidity 20C to 55C Star Epson Citizen IBM and compatible printers with RJ12 Printers Supported drawer port 2 Drawer function is limited to Printer options Piezo Electric Bu
3. led no external power supply required power is provided by the printer and a POS 108 USER MANUAL V2 1 Figure 3 POS108 Connection Panel Layout Figure 4 POS 108 Dimension Views Description dS Swit 2 Drawer Alarm option 1 Alarm will sound when cash drawer is left open for XX sec Alarm will sound for 60 seconds and shut off See Table 2 for value of XX DEFAULT Drawer Alarm option 2 Alarm will sound when cash drawer is left open for XX sec Alarm will sound until drawer is closed See Table 2 for value of XX Printer Alarm option 1 Alarm will sound for only XX second s when the trigger for any drawer is sensed no cash drawer is required Push Button to Silence Alarm See Table 3 for value of XX Printer Alarm option 2 Alarm will sound when the trigger for any drawer is sensed no cash drawer is required Push Button to Silence Alarm Table 1 POS108 Dip Switch 1 2 Definitions Description E SW 4 Drawer Alarm option 1 Wait 15 Seconds before Alarm D FF will sound DEFAULT Drawer Alarm option 1 Wait 20 Seconds before Alarm a will sound Drawer Alarm option 1 Wait 30 Seconds before Alarm S will sound Drawer Alarm option 1 Wait 40 Seconds before Alarm will sound Table 2 POSI08 Dip Switch 3 4 Cash Drawer Alarm Wait Timer for Option 1 POS 108 USER MANUAL V2 1 Description SW 3 SW 4 Printer Alarm option 1 Alarm will sound for 1 Second ON Table 3 POSI08 Dip Switch 3 4 Printer
4. Alarm ON Timer for Option 1 l Ground 2 Input i source pull up voltage source pull up voltage PU Power Power Input Open Drawer Status Open Drawer Status Switch Switch Input Table 4 RJ12 Drawer I and Drawer 2 pin out Epson Star Citizen Pin 1 2 Default IBM Printer Pin 2 3 Enable internal Buzzer Closed Default Disable internal Buzzer Open Connector for External Buzzer 24VDC Connector for External Push Button Table 5 Jumper location and description on the POS108 PCB Figure 5 POS108 PCB Panel Layout POS 108 USER MANUAL V2 1 The drawer solenoid is connected to 24 VDC and to the Drawer Sink Signal Typically pins 2 amp 4 is used for drawer 1 The Drawer Status Switch is connected to an Open Drawer Switch source pull up voltage and the switch is closed only when the cash drawer is OPEN typically pins 3 amp 6 Special Note The drawer trigger 2 for most POS Printers connects to the solenoid using Pin 4 amp 5 Since most cash drawers are wired to only use Pin 2 amp 4 The POS108 is designed to support the same type of cash drawer in both Cash drawer port 1 amp 2 See table 3 for pin out for both ports 1 6 iii TOP EE that Front ES 1 6 Looking into The connector Figure 9 RJ12 Connector Pin out for Drawer Cable and POS108 Connector 1 amp 2 Note The electronic Buzzer in the POS108 is powered POS printer RJ12 port A flashing LED indicates that an event is active Drawer is Open or
5. POS 108 USER MANUAL V2 1 POS 108 POS108 Cash Drawer Alarm option The POS108 provides Retailers peace of mind with their employees Thru selectable options the POS108 can notify employees with an electronic buzzer if a cash drawer 1s left open for more then a selectable amount of time 15 40 seconds The electronic buzzer can be selected to stay on for 60 second or stay on until all the drawers are closed Most IBM Star Epson Citizen and other compatible POS printers support two cash drawers but only provide one drawer connection The unique design of the POS108 provides the retailer the option of connecting two cash drawers to one POS printer without the use of special cables The POS108 also uses the same RJ12 cash drawer port off the POS printer for its power No external power adaptors is required See Figure 1 for the Connection illustration Note that Push Button on the POS108 has no effect on any Cash Drawer Alarm options The POS 108 also splits the cash drawer port of the POS printer to support 2 cash drawer port connections Only if the POS printer supports 2 cash drawers See required pin out for POS cash drawer port Figure 4 and Table 4 The POS108 has Built in Push Button and status LED See Figure 4 jopionall 2 cash drawer cash drawer fol a Figure 1 POS108 connection illustration for multiple cash drawers to one POS printer POS 108 USER MANUAL V2 1 POS108 Printer Alarm option The POS108
6. ss or merchantability for a particular purpose The Manufacture Shall not be liable for any special incidental or consequential damages nor damages due to use or misuse born from integration into any mechanical electrical or computer system The Manufacture Is not responsible for the accuracy of any device connected to the POS108 The Manufacture Reserves the right to make any changes to this manual or product s without obligation to notify any person of such changes Warranty is void if the case is opened by anyone other then The Manufacture s repair department or authorized repair center
7. zzer 4 5 kHz 90 dBA at 30 cm External Buzzer connection option The Drawers are triggered by the Cash Drawer pulse from the Drawer Triggers RJ12of Receipt Printer Cash Drawer port 2 Drawer function is limited to Printer options Alarm will sound if either drawers are left open manually or by the Drawer Alarm printer trigger Cash Drawer must have an RJ12 cable witha drawer normally open switch for the Drawer Alarm to function The printer alarm is triggered by the Cash Drawer pulse from the Printer Alarm RJ12 of Receipt Printer Cash Drawer port NO Drawer needed External Push Button Connection option Operating System Not dependent on any operating system or software Table 6 Technical Specifications Note This equipment has been tested and found to comply with the limit for a class A digital device pursuant to part 15 of the FCC rule These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Disclaimer The Manufacture Makes no claims or warranties with respect to the content or accuracy of this publication or the product is describes including warranties of fitne

Download Pdf Manuals

image

Related Search

Related Contents

Télécharger manuel et vues éclatées - Solano  VMWARE VSPHERE : TROUBLESHOOTING  Smart Office Suite 6.1  a <3 €?`1  Extron electronic PMK 350 User's Manual  SUP Air - Owner guide  Manuale d`installazione porta base ALU SF (tutti i tipi e misure)  Manuale utente  Thermac Simulator Software Operation Manual  EN / FECA-01 EtherCAT adapter module user`s manual  