Contents

1. 10V controller may be out of work D1 type port must connect DC by Power Transformer 4 Specifications TYPE Al A2 A6 D1 Rated charge current 5A 10A 15A 20A Rated load current 5A 10A 15A 20A 1 25 times of rated load current 60 sec 1 5 times of Load protection rated load current 5 sec overload protectionwill be triggered Over 3 times of rated load current short circuit protection will be triggered Quiescent current lt 5mA Work temperature 35C to 50 C Work voltage 12V 24V 36V 48V Over voltage protection T OV 34 OV 51 OV 68 OV Boost charge voltage 4 8V 29 6V 44 4V 59 2V Direct charge voltage 4 4V 28 8V 43 2V 57 6V Float charge voltage 3 7V 27 4V 41 1V 54 8V Lower voltage indicate 2 OV 24 OV 36 OV 48 OV Over discharge voltage AV 22 2V 33 3V 44 4V Over discharge return voltage 2 6V 25 2V 37 8V 50 4V Temp compensation 3mv C 2V Real clock Real clock Comunication Off Line Real Time Two Shunt Two Independent One load Load load output load output Direct current or preset frequency output Dimension 145 92 29mm Weight 1509 250g
2. SOLAR CHARGE CONTROLLER USER MANUAL Charge and discharge protection When the battery charge is full the System LED will be green and flash slowly When the voltage of the battery is undervoltage the System LED will glow orange If it continues to fall to over discharge status the System LED will glow red and simultaneously turn off output In case of short circuits or overload the controller will shut down output until the following sunrise The Load Led will flash fast if short circuits occur in case of overload the System LED will glow red and flash slowly When charging PV LED will flash When Output is on Load LED will be on Start Point setting Press button for ten seconds until PV State LED begins to flash and System State LED and Load State LED will be out Pressing button again will save current PV voltage as start point to memory Light on off control mode The load will work all night When PV output voltage drop under start point voltage load will be open after ten minute Closing load has ten minute delay also Light on time delay off mode The start process is the same as in the Light on off control mode but the load will be shut off at the set time see table to select time Common control mode Open or close load by pressing button Test mode Be used to test ON OFF of load easily Work mode will be switch to test mode when press button for 15 seconds until Load State LED begins to flash Pres
3. off when sunlight falls on Check if the solar panel s cables are PV panel connected properly System LED is green or yellow but no Check the load s cables are connected power output to the system properly Check output circuit of load for short System LED flashes red but there is no circuit or overload Re connect the Bat power output or LOAD LED flash fast again to reset the system or wait until the next day System LED is red but there is no The Bat is over discharged Wait until power output the system has recharged the battery 2 Features 1 Automatic boost recovery and float charging capacities for extended battery life use temperature compensation 2 Over discharging control voltage modified by the battery discharging rate curve 3 Protected against overload internal and external short circuits reverse connection thunder and lightning and PV panel reverse current 4 Clear LED display for reliable reporting of the system s condition 5 Industry standard production ensures durability and efficiency Comfortably operate within a wide temperature range 6 Uses EEPROM memory to save all work 7 Control point instead of adjustable resistance to protect the control work point from temperature and vibration fluctuations 8 PWM high efficiency charging is recommended for optimal operation 9 System parameter can be set by computer through serial comnication Installation 1 Prepare
4. s key again to exit test mode System Led Description LED Color System Status LED Color System Status Green Normal Orange Undervoltage Green Flash Battery Full Red Overdischarge Green Flash fast Battery overvoltage Red Flash Fast Overtemperature Red Flash Overload Orange Flash Fast Fuse fusing Parameter setting Press the key and hold for approx 5 seconds until three simultaneously Press the button again three LED will denote current work mode Continue to press the button three State LED wil below 1 LED begins to flash be shown as table Press the button and hold for approx 5 seconds will save setting into EEPROM No button press for 15 seconds will return normal status Press theif it is A2 light on off control mode is cancel A2 type if want to set time B firtly change woke mode to light on off control mode and save it then you can adjust second load on time OLED light OLED off OOO Light on time delay off mode Light on off control mode A2 Time B Setting Common control mode Time Timing mode Bat Cap Common control 4 Hours 17AH 5 Hours 40AH 6 Hours 80AH 8 Hours 150AH 0000 00 0500 e 0000 006 600 10 Hours 200AH Note use customized communication device to connect computer and use customized software to set parameter by friendly interface Problems amp Troubleshooting Problems Solutions The PV LED if
5. wire Choose a plastic coated copper wire Cut the wire to the shortest length possible then peel 5mm of plastic from end 2 Connect exposed end of wire to battery port of controller and then with the battery paying careful attention to the poles of the connection if the poles are reversed the controller won t be damaged but it won t work 3 Repeat wire preparation and connect wire to solar panel port of controller and then to solar panel If connection is correct and the PV panel is exposed to sunlight the charging indicator will glow green 4 Repeat wire preparation and connect the load to the load port of controller again taking care to correctly connect the poles Caution If the system voltage is above 24V avoid touching any conductor with bare hands during installation in case of electrical shock 133mm oO a 60mm e PV LED 4 _ BUTTON System LED Solar Charge Controller IN A O 9 a Load LED PEPPPPPRI COM PV BAT LOAD LOAD A1 LOAD B A2 Note A6 controller A and B port of RS485 interface must be connected by A A and B B A1 A2 controller can be connect to computer by COM port when controller is not installed COM port only receive TTL level x lf system voltage is 36V or 48V please connet PV to controller correctly reverse connect may break controller If bat voltage is lower than

Download Pdf Manuals

image

Related Search

Related Contents

Saeco Saeco HD8751/41 coffee maker  installations de gaz (dtu 61-1). - Jean  Page 1 Page 2 流量測定について 関連法規    Olympus VN-2100PC DVR User Manual  - WalkAide  La Lettre Bureau Veritas 25 - Page d`accueil  L`ISLE-JOURDAIN A ENFIN SA DÉCHETTERIE !  廃棄自転車の処理調査  Bedienungsanleitung Manuel d`instruction - Migros  