1. 1 5 Functions and Configuration 1 5 1 Function e This application will start after NC is started up using Startup service e This application allows MTConnect Agent provided by MTConnect to collect machine data e The system performs the following tasks routinely Send update data to connected Agents Note All error messages will be set as top mode and cover NC screen Operator will need to acknowledge the message by touching the application 1 6 Scope Current version of OKUMA MT Connect Adapter only supports OKUMA P200 controls or higher This adapter must be used with an agent developed by MTConnect org and can be download at https github com mtconnect cppagent 1 7 References 1 Installation Manual for THINC API 2 Installation Manual for Startup Service Okuma America Corporation 2012 Page 5 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 2 Installation 2 1 Installation of THINC API This application requires THINC API version 1 12 1 0 or greater to be installed on machine Refer to THINC API InstallationManual pdf provided on THINC API Installation disk for instructions Tip Try to run THINC API Demo Application and see if it runs normally to make sure THINC API is properly installed It is always best to install the latest version of THINC API on the machine if possible 2 2 Installation of Okuma MTConnect Adapter Software Run the Setup exe program from the Okuma MTConnect Adapter
2. DVD to install Okuma MTConnect Adapter software The setup program automatically checks if Microsoft NET framework 4 0 3 5 SP1 is installed If it is not installed continue to section 2 2 1 otherwise refer to section 2 2 3 OSP software should not be running during the installation of Okuma MTConnect Adapter or NET Framework 4 0 During the NET installation it will be necessary to reboot multiple times OSP software launch should be cancelled and the installation media should remain connected during the reboot 2 2 1 Installation of Microsoft NET Framework 4 0 The next dialog will be displayed if Microsoft NET framework 4 0 is not installed Okuma America Corporation 2012 Page 6 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 P OKUMA TMSA MA Setup E xi For the following components Microsoft NET Framework 4 x86 and x64 Please read the following license agreement Press the page down key to see the rest of the agreement MICROSOFT SOFTWARE SUPPLEMENTAL LICENSE TERMS MICROSOFT NET FRAMEWORK 4 FOR MTCROSOFT WINDOWS OPFRATING xi 6 View EULA for printing Do you accept the terms of the pending License Agreement If you choose Don t Accept install will close To install you must accept this agreement Figure NET framework 4 0 license agreement dialog Click Accept to install NET framework 4 0 5 OKUMA TAMSA MA Setup EE xi X Installing Microsoft Frame
3. Figure THINC startup settings add item destination dialog Click the Browse button to select file OkumaMTConnectAdapter exe in the Okuma MT Connect Adapter installation folder By default it is D Program Files Okuma Okuma MT Connect Adapter Click Next to proceed to next Startup Options dialog Okuma America Corporation 2012 Page 16 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 Option Included Enabled Launch Wait Sequence Select All Clear All Delay Argument Username M M MSEXEXI Password Figure THINC startup settings add item options dialog In the Startup Options dialog check Enabled Launch and Wait then click Next button to go to next step Okuma America Corporation 2012 Page 17 OKUMA MTConnect Adapter S5053 03 05 Date 03 29 2012 ll Add Item The following startup entry will be created Display OKUMA MTCONNECT ADAPTER Type Process Name Okuma TConnectAdapter File D Program files Okuma Okuma MT Connect Adapter OkumaMTCo Startup options Enabled Included Launch Included Wait Included Sequence Not Included Delay Not Included Argument Not Included Username Not Included Password Not Included Click Finish button to finish the setup for Okuma MTConnect Adapter Software Okuma America Corporation 2012 Page 18 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 La Thinc Start
4. MIConnect Adapter NEED x File View Help Configurations s Date 11 21 2011 Time 8 03 24 PM Information Initialization completed Date 11 21 2011 Time 8 03 24 PM Information System starts monitoring 8 Date 11 21 2011 Time 8 03 24 PM Information Loading application configuration OK sl Date 11 21 2011 Time 8 03 24 PM Information Finish initializing TCP Server OK s Date 11 21 2011 Time 8 03 24 PM Information Initializing TCP Server sl Date 11 21 2011 Time 8 03 24 PM Information Initialize Machining Center OK Date 11 21 2011 Time 8 03 07 PM Information Machine type is determined as machining center S Date 11 21 2011 Time 8 03 07 PM Information Finish reading configuration file DAProgram files Okuma OKUMA MT Connect Sampling Period 1000 msec Communication Status Figure Okuma MTConnect Adapter Software main user interface 5 2 Exit Okuma MTConnect Adapter Application When user shuts down the machine the software will be terminated automatically without user interaction Click the exit button x will also terminate the software In normal operation only user with administrative right can perform this operation 5 3 Main User Interface 5 3 1 Main Menu The main menu is at the top of main user interface including four submenus which are File View and Help submenu 5 3 2 File Menu The File menu has one submenu item which is Exit When t
5. Okuma MT Connect Adapter Machining Center This dialog provides custom setup for Okuma MTConnect Adapter 1 Device Information Device Name Name of machine as specified in Devices xml Note Device or Machine name must be matched with device name specified in the agent configuration file Agent cfg Device Serial Number Unique machine number Device Description A description of this machine 2 OK button The system will save current setting and update device configuration file accordingly 3 Cancel Button This will cancel current installation Click OK to move to next step Okuma America Corporation 2012 Page 12 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 ie OKUMA MT Connect Adapter Installation Complete OKUMA MT Connect Adapter has been successfully installed Click Close to exit Please use Windows Update to check for any critical updates to the NET Framework Close Figure Installation completed dialog Click Close to complete the installation 2 3 Installation of THINC Startup Service Run the Setup exe in the Okuma Startup Service System DVD to install THINC Startup Service Note User needs to restart the machine to make the startup service work properly 2 4 Setup Okuma MTConnect Adapter Software to Startup Automatically To enable the Okuma MTConnect Adapter Software run automatically when NC OSP system is started user needs to setup THINC Startup Service
6. properly Click Start gt Programs gt Okuma gt THINC Startup Service gt THINC Start Settings to activate the startup service setup dialog as follows Okuma America Corporation 2012 Page 13 OKUMA MTConnect Adapter S5053 03 05 Date 03 29 2012 Ni Thinc Startup Settings New Entry Delete Entry Figure 1 THINC startup settings dialog Click New Entry button at the lower left side of the dialog to add an entry for the Okuma MTConnect Adapter application CEEE Add Item CEEE Welcome to the Add Item Wizard This wizard will help add a new item to the startup list lt Back o Net coca Figure THINC startup settings add item welcome dialog Okuma America Corporation 2012 Page 14 OKUMA MTConnect Adapter S5053 03 05 Date 03 29 2012 Add Item I Type Process C Service lt Back Next gt Cancel Figure THINC startup settings add item name dialog In the Add Item welcome window click Next to enter the Startup Type selection dialog enter Okuma MTConnect Adapter as display name and select Process for the startup type then click Next button and a new dialog will pop up to allow user to browse which application to startup Okuma America Corporation 2012 Page 15 OKUMA MTConnect Adapter S5053 03 05 Date 03 29 2012 Add Item lt Back Next gt Cancel
7. Configuration Configuration OkumaM TConnectA dapter P Device has not been configured by the application yet The application must be able to connect to NC first to allow the application configure Devices xml File correctly Okuma America Corporation 2012 Page 28
8. Okuma America Corporation Okuma MTConnect Adapter Software User Manual Document No S5053 03 05 OKUMA MTConnect Adapter S5053 03 05 User Manual Date 03 29 2012 Revision History 02 10 2012 55053 03 03 Release 1 3 6 Update Linh Huynh a T 02 20 2012 S5053 03 04 Release 1 3 7 Update Linh Huynh a 02 29 2012 S5053 03 05 Release 1 3 8 Update Linh Huynh Ada 2 6 Installing MT Connect Agent Optional Revise 5 4 and 7 1 Okuma America Corporation 2012 Page 2 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 Okuma MTConnect Adapter 1 Document No 5053 03 05 1 Revision History 2 2 6 Installing MTConnect Agent Optional 2 1 Introduction 5 1 Purpose 5 1 2 Scope 5 1 3 Definitions Acronyms and Abbreviations 5 14 Overview 5 1 5 Functions and Configuration 5 1 5 1 Function 5 1 6 Scope 5 1 7 References 5 2 Installation 6 2 1 Installation of THINC API 6 2 2 Installation of Okuma MTConnect Adapter Software 6 2 2 1 Installation of Microsoft NET Framework 4 0 6 2 22 Installation of Microsoft NET Framework 3 5 SP1 7 2 2 3 Installation of Okuma MTConnect Adapter Software 8 2 3 Installation of THINC Startup Service 13 2 4 Setup Okuma MTConnect Adapter Software to Startup Automatically 13 2 5 Installing MTConnect Agent Optional 19 3 Repair Uninstall Okuma MTConnect Adapter Software 19 3 1 Un install Okuma MTConnect Adapter Software 19 4 Installation Files 20 4 1 Okuma MTConnec
9. date Devices xml accordingly In normal operation only user with administrative right can perform this operation 3 Cancel Button This will cancel current installation Note All current agents must connect to the OKUMA MTConnect Adapter again after system configuration 5 4 2 System Events By default the system will write event messages to the System Events tab in the descending order such that newest event message will be displayed on the top of the list If the Trace On menu is checked all messages will be displayed on the main user interface otherwise only pre selected event messages by the system will be displayed Event messages are categorized into different event types as following Okuma America Corporation 2012 Page 24 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 Information Indicate normal event messages It is in black color Tracing Indicate tracing event messages when Trace On mode is enabled from menu It is in blue color Warning Indicate warning event message It is in orange color Error Indicate error event messages when system encounters Error messages will be forced to display to main GUI and logged It is in red color Fatal Indicate critical error event messages when system encounters Error messages will be forced to display to main GUI and logged It is in violet color By double clicking on the event message in each row a message box will be displayed con
10. ent configuration for correct device name 7 1 3 Agent Port number MTConnect client application could not connect to agent Probable faulty locations e default agent is running on port 5000 Measure to take e Check client application to connect with agent on port 5000 e Check network configuration for allowing connection with current setting port in agent 7 1 4 Adapter Port number MTConnect agent could not connect to OKUMA MT Connect Adapter Probable faulty locations e By default OKUMA MT Connect Adapter is running on port 7878 Measure to take e Check agent configuration file to connect with adapter on port 7878 or current port setting e Check network configuration for allowing connection with current port number 7 1 5 Device Configuration In order to configure device the application must be able to connect to NC The adapter will configure generated and configure the Devices xml once it can connect to NC Probable faulty locations e Devices xml file is not available yet due to NC is not running yet Measure to take e Start Okuma MTConnect Adapter after NC is fully started e Registered Okuma MTConnect Adapter with Startup Service to allow the adapter to start after NC is fully started so it can generated and configure Devices xml file correctly Okuma America Corporation 2012 Page 27 OKUMA MTConnect Adapter S5053 03 05 User Manual Date 03 29 2012 System Events Configurations System Device
11. ge will be displayed in the system event There are schemas of MTConnect included in the installation folder if needed by client applications The OSP P control does not natively include a compatible HTTP application for capturing the agent xml stream 6 Event Log 6 1 Error Event Log The error information for the application is logged in the Windows event log which user can read from windows system Event Viewer The source for this event log is Okuma MT Connect Adapter To view the event log press Ctrl on the operation panel pop up Start Menu then click Settings gt Control Panel gt Administrative Tools gt Event Viewer to launch windows event viewer click OACMT Adapter under Event Viewer Local to see a list of events logged for Okuma MTConnect Adapter application To see the detail of each event Okuma America Corporation 2012 Page 25 OKUMA MTConnect Adapter S5053 03 05 Date 03 29 2012 double click the event item 7 Trouble Shooting By default the system will write event messages to the main user interface If the Trace On menu is checked all messages will be displayed on the main user interface otherwise only pre selected event messages by the system will be displayed Note When the Trace On menu is checked all process states monitored in the system will be displayed on the event message tab when the states are changed as shown BS Okuma MTCo
12. grams in control panel find the item Okuma MTConnect Adapter and click Remove to uninstall Okuma MTConnect Adapter Software Note Before performing un installing Okuma MTConnect Adapter application please shutdown the Okuma MT Connect Adapter application if it is running Okuma America Corporation 2012 Page 19 OKUMA MTConnect Adapter S5053 03 05 Date 03 29 2012 6 Add or Remove Programs EI Currently installed programs and updates Show updates Sort by Name v Change or ese 2126 1 950 UU Remove Programs NVIDIA nView Desktop Manager Size 17 00 15 Okuma Coolant Monitor Size 59 39 Okuma Freedom eLog Interface 2 57MB Add New ER OKUMA MT Connect Adapter size Programs aer Ize Click here For support information Used m To change this program or remove it From your computer click Change or Remove Add Remove Windows U okuma Tamsa 5 12 58MB die dado Okuma THINC Startup Service Size lim e mma Figure Uninstall Okuma MT Connect Adapter software dialog Add or Remove Programs 2 4re you sure you want to remove OKUMA MT Connect Adapter from your computer Figure Uninstall Okuma MT Connect Adapter software confirmation dialog Click Yes to confirm uninstalling Okuma MTConnect Adapter Software 4 Installation Files 4 1 Okuma MTConnect Adapter Software All the files are installed in the installati
13. gure Installation welcome dialog Okuma America Corporation 2012 Page 8 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 Click Next to continue ie OKUMA MT Connect Adapter Select Installation Folder The installer will install OKUMA MT Connect Adapter to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder D Program Files Okuma OKUMA MT Connect Adapter Install OKUMA MT Connect Adapter for yourself or for anyone who uses this computer Everyone O Just me Figure Installing Application folder Click Next to continue User can also select a different folder other than the default one to install Okuma MTConnect Adapter Software Okuma America Corporation 2012 Page 9 OKUMA MTConnect Adapter S5053 03 05 Date 03 29 2012 i OKUMA MT Connect Adapter Click Next to continue Okuma America Corporation 2012 Page 10 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 ie OKUMA MT Connect Adapter Installing OKUMA MT Connect Adapter DKLIMA MT Connect Adapter is being installed Please wait Cancel Application is installing Okuma America Corporation 2012 Page 11 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 Device Configuration Form Device Information Device Serial 123456 Device Name OKUMA Mach ini in gCe nter Device Description
14. he Exit submenu item is selected the application will be closed Okuma America Corporation 2012 Page 21 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 5 3 3 View Menu The View menu has four submenu items which are Clear Messages Trace On System Tray and Get Current When the Clear Messages submenu item is selected all the messages displayed in the client area of the main user interface are erased When the Trace On submenu item is checked a message is displayed when data item is changed if there is at least 1 client connecting to the system When the System Tray submenu is selected the main user interface is hidden and the icon for this application is shown in the system tray of windows task bar When the Get Current menu is clicked the system will display a message in the System Events tab The message contains all current values of all components currently supported by the device 5 3 4 Help Menu The Help menu has one submenu item About When the About submenu item is selected a dialog is displayed to show the information about this application EM Okuma MTConnect Adapter About Okuma MTConnect Adapter Version 1 2 0 0 CopyrightO 2011 OKUMA Figure Okuma MT Connect Adapter About box 5 4 Operations The OKUMA MTConnect Adapter application s main interface has 2 tabs which are System Configurations and System Events 5 4 1 Configu
15. nnect Adapter SUB si Date 7 21 2011 Time 4 04 39 PM Information Current Sampling 2011 07 21715 51 10 600 power ON avail UNAVAILABLE a Date 7 21 2011 Time 4 04 37 PM Information Trace on a Date 7 21 2011 Time 3 51 18 PM Information Initialization completed sj Date 7 21 2011 Time 3 51 18 PM Information System starts monitoring si Loading application configuration OK a Date 7 21 2011 Time 3 51 18 PM Information Initialize Machining Center OK sj Date 7 21 2011 Time 3 51 10 PM Information Machine type is determined as machining center sj Date 7 21 2011 Time 3 51 09 PM Information Finish reading configuration file DAProjectsiSoftwareiPCS 5053 MTConnect So OkumaM TConnectAdapter 1 Date 7 21 2011 Time 4 04 39 PM Information Current Sampling 2011 07 21T15 51 10 600 power ON avail UNAVAILABLE Sampling Period 1000 msec Communication Status OFF Monitoring 7 1 Common Errors 7 1 4 THINC API License Failed to start application correctly Probable faulty locations e Older version of THINC is installed on control Measure to take e Install the latest version of THINC API on control 7 1 2 Devices Name MTConnect Agent could not connect to OKUMA MTConnect Adapter Probable faulty locations Okuma America Corporation 2012 Page 26 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 e MTConnect device name is case sensitive Measure to take e Check ag
16. on folder unless otherwise noted by default which is D Program Files Okuma Okuma MT Connect Adapter The devices xml configuration file will be created and configured per machine type and specification by OKUMA MTConnect Adapter Once it is configured the device is available for communicating with an agent Note It is necessary to run OKUMA MTConnect Adapter application after NC is started completely to allow the application to configure the devices xml file correctly per machine configuration and specification Once it is configured MTConnect agent can connect to it Okuma America Corporation 2012 Page 20 OKUMA MTConnect Adapter S5053 03 05 Date 03 29 2012 5 Usage 5 1 Start Okuma MTConnect Adapter Application The Okuma MT Connect Adapter Software will be launched automatically by the Start Up service after NC is started completely If user exits the software and wants to launch it again press Ctrl on the operation panel to pop up Start Menu then click Programs gt Okuma gt Okuma MTConnect Adapter gt Okuma MTConnect Adapter Application to run After the application is launched without error it will be minimized in the system tray and shown as an icon U If user double clicks the icon or select Show from the pop up menu the main user interface will be displayed Note The detail messages displayed in the main user interface does depend on each machine configuration Okuma
17. pt new heartbeat time from client Note All current agents must connect to the OKUMA MT Connect Adapter again after system configuration In normal operation only user with administrative right can perform this operation 5 4 1 2 Device Configuration This operation allows user to set MTConnect device configuration for the application Upon completion of device configuration the system will try to re initialize completely with new configuration It requires an administrative level to perform The system will verify the input user name and password before allowing user to save the configuration Okuma America Corporation 2012 Page 23 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 Note The system configuration must have been configured first before Device Configuration is allowed It is based the current Devices xml configuration file of current machine specification Device Configuration Form Device Serial Device Name Device Description This dialog provides custom setup for Okuma MTConnect Adapter 1 Device Information Device Name Name of machine or device name as specified in device xml Note Device or Machine name must be matched with device name specified in the agent configuration file agent cfg and it is case sensitive Device Serial Number Unique machine number Device Description A description of this machine 2 OK button The system will save current setting and up
18. rations This tab provides configurations for the application Notes Any change in the System or Device Configuration might update the Devices xml file accordingly Okuma America Corporation 2012 Page 22 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 5 4 1 1 System Configuration This operation allows user to configure different configurations for the application Upon completion of configuration the system will try to re initialize completely with new configuration It requires an administrative level to perform The system will verify the input user name and password before allowing user to save the configuration Configuration Setting Dialog System Settings Polling Time msec Server Setting Max Client Connections TCP Server Listening Port Local Agents Only Heartbeat Time second Polling Time msec Polling interval is in msec Default value is 1000 msec It should not be less than 100 msec interval Max Client Connections Number of agents can connect to this Adapter Default value is 10 agents TCP Server Listening Port The port number where it is listening for incoming connection of agents Default value is 7878 Local Agents Only By checking it only accepts agents running on local machine Heartbeat Time The numbers of seconds the adapter will send a message back to the connected agent when it received a ping from the connected server Note Agent must be restarted to be able to acce
19. t Adapter Software 20 5 Usage 21 5 1 Start Okuma MTConnect Adapter Application 21 5 2 Exit Okuma MTConnect Adapter Application 21 5 3 User Interface 21 5 3 1 Main Menu 21 5 3 2 File Menu 21 5 3 3 View Menu 22 5 3 4 Help Menu 22 5 4 Operations 22 5 4 1 Configurations 22 5 4 2 System Events 24 5 4 3 Components Data Items 25 5 4 4 Agent amp Adapter Communication 25 6 Event Log 25 6 1 Error Event Log 25 Okuma America Corporation 2012 Page 3 OKUMA MTConnect Adapter S5053 03 05 Date 03 29 2012 7 Trouble Shooting 26 7 1 Errors 26 7 1 1 THINC API License 26 7 1 2 Devices Name 26 7 1 3 Agent Port number 27 7 1 4 Adapter Port number 27 7 1 5 Device Configuration 27 Okuma America Corporation 2012 Page 4 OKUMA MTConnect Adapter S5053 03 05 Date _03 29 2012 OKUMA MTConnect Adapter User Manual 1 Introduction 1 1 Purpose The purpose of this document is to provide the instruction of installing and operating Okuma MTConnect Adapter It also provides information on how to repair and uninstall this software 1 2 Scope This manual will cover the installation operation and trouble shooting for Okuma MTConnect Adapter running on OSP P200 controls 1 3 Definitions Acronyms and Abbreviations None 1 4 Overview The Okuma MTConnect Adapter is an application that is specifically designed to support the communication interfaces between MTConnect Agent and Okuma OSP P100 P200 controls
20. tained the message in the current selected row When the system encounters an error and the application is currently not visible the application will be displayed and will be on top of other applications current running in Windows including NC HMI This allows user to perceive the error currently active in the system If application is in Top Most mode it will be out of this mode when user clicks on the application Note Error happened during initializing or applying new system configuration must be resolved in System Configuration 5 4 3 Components Data Items The components and data items that can be supported by this adapter are described in the Devices xml configuration file 5 4 3 1 Data Items The system will monitor all data items listed in Devices xml per machine configuration and sends out only the data items having value being changed to the connected agents Any agent first connects to the system will receive all data items values 5 4 4 Agent amp Adapter Communication This adapter will send data to the connected MT Connect agents using socket in a pipe delimited stream according to the descriptions given in the adapter guide by MTConnect The agent can be run on the same PC where the adapter running or can be run on a remote PC It is up to the end user to configure the agent configuration file and adapter communication channel for local or network connection Each time an agent is connected or disconnected a messa
21. up Settings E 10 x FREEDOM ELOG okuma tamsa ma system OKUMA TAMSA MB E Read Only SETE File D Program files Okuma Okuma MT Conn SEY OL ER tin Name OkumaMTConnectAdapter Type Process E Read Wirte Enabled True Launch Once Wait True Name Proper Name Delete Save Cancel Apply Figure THINC startup settings add item completed dialog v Restart After Changes Applied Click Save to save the settings and exit the setup process The Okuma MTConnect Adapter Software should be launched automatically after the NC OSP system is started Note User needs to restart the machine to ensure that the startup service work properly 2 5 Installing MTConnect Agent Optional MTConnect Agent is installed into the same location of OKUMA MTConnect Adapter It is however up to user to decide to run agent on the same or different PC Please refer to the MTConnect Agent installation file named README pdf for further instruction how to configure it to connect to adapter Note It is important to update agent configuration setting when OKUMA MTConnect Adapter device information has been changed 3 Repair Uninstall Okuma MTConnect Adapter Software 3 1 Un install Okuma MTConnect Adapter Software Start the machine in Windows only mode Click Start gt Settings gt Control Panel to launch control panel Double click Add or Remove Pro
22. work 4 85 and x64 Figure NET framework 4 0 installation dialog If the NET installation requires rebooting then it needs to reboot the machine to continue the installation again 2 2 2 Installation of Microsoft NET Framework 3 5 SP1 The next dialog will be displayed if Microsoft NET framework 3 5 SP1 is not installed Okuma America Corporation 2012 Page 7 OKUMA MTConnect Adapter S5053 03 05 Date 03 29 2012 Figure NET framework 3 5 SP1 license agreement dialog Click Accept to install NET framework 3 5 SP1 Okuma Tool ID System Setup xj Y Installing NET Framework 3 5 5 1 Cancel Figure NET framework 3 5 SP1 installation dialog If the NET installation requires rebooting then it needs to reboot the machine to continue the installation again 2 2 3 Installation of Okuma MT Connect Adapter Software The following dialog will be displayed once all of the required NET frameworks are installed i OKUMA MT Connect Adapter Welcome to the OKUMA MT Connect Adapter Setup Wizard The installer will guide you through the steps required to install OKUMA MT Connect Adapter on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Cancel Fi