Home

User manual, Bellman Alarm clock (GB) How to get started:

image

Contents

1. K 12 i 40 Ae ue User manual Bellman Alarm clock GB NC 3 Pi Bellman Visit Alarm clock model BE1345 is a table top clock with extra functions It signals when one of the transmitters in the Visit system is triggered when the door bell or telephone rings or the Baby cry or fire alarm is activated e Snooze function e Wake up alarm with a sound signal with increasing intensity and volume and or clear flashes e The number of flashes and their interval is automatically adjusted depending on the surrounding light e Two Bellman Visit Bed shakers accessory can be connected for wake up through vibrations e The clock face is illuminated and lights up for wake up and also when the snooze button is pressed e The alarm clock can be connected to a telephone outlet to signal for incoming calls and also to an external trigger e It has a built in rechargeable back up battery that is activated upon power failure or when the clock is not connected to the mains supply How to get started 1 Power supply Connect the power adapter to the inlet 13 marked DC IN 7 5V on the backside of the unit Let the unit be connected for 24 hours first time of usage to allow the back up battery to fully charge This will increase the life span of the battery Normally 16 hours is required to fully recharge an empty battery Please note Use only the attached power adapter type GO75040D25 The rechargeable battery NiMH steps in when the clock no longe
2. already have changed the radio channel in your transmitters see each manual you will need to change the channel in your clock too For safety reasons the Bellman Visit Fire alarm transmits on all channels How to change radio channel 1 Place the clock next to a transmitter 2 Hold the snooze button 5 pressed in for approx 5 seconds until the indicators for the door bell green and the telephone yellow flashes alternatively Release the snooze button 3 Press the test button of one of your transmitters As confirmation all the LED indicators 3 on the clock will start to flash alternatively Connection of Bellman Visit Bed shaker One or two Bellman Visit Bed shakers can be connected to the outlets 17 the back of the clock The vibration pattern during wake up is short vibrations with long pauses When indicating ring signal see Connection to telephone outlet below it is repeated short vibrations These vibrations continues until the snooze button 5 is pressed or for no more than 30 seconds when indicating ring signal Connection to telephone outlet On the back of the clock there is a modular outlet 16 for connection to the telephone line When there is an incoming call the alarm clock will signal with an acoustic ring signal and clear flashes The connecting cable is an accessory which can be obtained at your nearest Bellman amp Symfon retailer The sound and the flashes can each be turned On or Off using the
3. p the clock face is illuminated The snooze function which turns the alarm on again after about 3 5 minutes is activated when the snooze button 5 is pressed down The indicator inside the snooze button will then flash if the unit is connected to the mains supply Miscellaneous The flash There is a light sensor 4 mounted on the clock face which regulates the number of flashes and their interval to about 12 during the day and about 8 at night When indicating ring signal if the clock is connected to a telephone outlet the clock sends about 5 flashes day or night Extra knob for turning the alarm On Off There is an extra knob that can be mounted on the regular knob 6 for alarm On Off to increase usability Illumination of clock face The clock face can be illuminated at any time by pressing the snooze button 5 The clock face is automatically illuminated at wake up Signal indication from the Bellman Visit System There are 4 differently coloured LED indicators 3 on the clock face that indicates the following Orange baby Green door Yellow telephone Red Fire The indicators on the clock face shines for a while during the alarm Meanwhile the flash and Bed shaker outlet is activated The flash and the Bed shaker will stop when the snooze button 5 is pressed For safety reasons the fire alarm signal cannot be turned off Radio channel Upon delivery all units are set to the same radio channel If you need to change or
4. r is powered via the power adapter A fully charged battery lasts approximately one week of normal usage but it is recommended to always let the unit be connected to the adapter Power supply indicator 2 Shines with a constant green light during normal usage when the power adapter is connected flashes with green light during power failure or when the power adapter is not connected flashes with a red light when the back up battery is low and needs to be recharged 2 Adjusting time Use the knob 12 on the back of the unit to set the correct time 3 Adjusting time for wake up 1 Set the time for wake up using the knob 11 on the back of the unit 2 The wake up alarm is turned on or off using the knob 6 marked ALARM on the right side of the unit 3 When the alarm is on a red indicator inside the snooze button is lit Please note Only available when the unit is connected to the mains supply 4 Wake up can happen through sound and or flashes as well as through vibrations accessory The sound and the flashes are activated through the switches marked 8 and 10 on the back of the unit Set these in desired mode Wake up Wake up happens through a sound signal with increasing intensity and volume with clear and distinct flashes and through vibrations if the Bellman Visit Bed shaker model BE1270 accessory is connected If the alarm is not turned off within 30 minutes it will stop automatically Upon wake u
5. stment knob 12 Time adjustment knob 13 Inlet for power adapter 14 Inlet for external triggering 15 Programming socket 16 Modular connector for the telephone accessory 17 Outlet for 2 Bellman Visit Bed shaker accessory Address Our office hours are Telephone 46 31 682820 Bellman amp Symfon AB Mon Fri 08 00 12 00 12 45 16 30 Fax 46 31 682890 S dra L ngebergsgatan 30 Homepage www bellman com 421 32 V STRA FR LUNDA Sending us company e mail infoQbellman symfon se Sweden
6. switches marked 8 and 10 on the back of the clock Make sure they are set in the desired mode External triggering The alarm clock can be triggered by an external source via the inlet Ext trig 14 on the back of the clock The sound and the vibration patterns of connected bed shakers are set via the switches 1 4 9 marked EXT TRIG To reset or turn the signal off simply press the snooze button 5 See further technical information Trouble shooting Follow the troubleshooting instructions below before calling for service Symptom There is no flash There is no sound It doesn t receive any signals from the Bellman Visit system It indicates signals from the Visit system for no reason Procedure Check the switch 10 that turns the flash On Off Check that the power adapter is connected and or that the back up battery is charged see Power supply indicator Check the switch 8 that turns the sound On Off Check that the power adapter is connected and or that the back up battery is charged see Power supply indicator Make sure it uses the correct radio channel see Radio channel Change radio channel see Radio channel Product description 1 Power supply indicator 2 Alarm hand 3 Signal indicators 4 Light sensor 5 Snooze button 6 Alarm On Off 7 Stand 8 Sound signal On Off 9 Settings for signaling when for external triggering 10 Flash On Off 11 Alarm adju

Download Pdf Manuals

image

Related Search

Related Contents

G411350B アルミジャッキ1.35t  DEWALT DWE7480 Use and Care Manual  Manual de Usuario    

Copyright © All rights reserved.
Failed to retrieve file