USER'S GUIDE
Contents
1. During an adjustment session all parameters may be reset to their factory values as following PARAMETERS OPERATIONS DEFAULT Press the SETUP key 19 then press the NUMBER key 9 All the parameters are reset to the factory values see next table VALUES i DEFAULT VALUES x Factory Values Table Parameter Sensitivity Hold time Detection field Pulse frequency Output configuration Door control Maximum duration of presence detection The detection pattern is made of 15 independent spots organized in 3 ranges of 5 spots parallel to the door DETECTION FIELDS Each spot can be individually switched on or off in order to produce the most adapted detection field Ex a deep and thin field if the RS 15 is facing the sitting passengers or a wide and deep field if the RS 15 is covering the platform Furthermore each spot can be set to detect either motion see grey spots bellow or presence see black spots bellow Given the many options a pre selection of 9 typical sensing fields is programmed into the sensor These fields can be selected via the remote control or the push buttons as explained hereafter TROUBLESHOOTING SYMPTOMS PROBABLE CAUSES CORRECTIVE ACTION The sensor will not power up Faulty power supply Assure a correct power supply Door keeps opening and closing The sensor is disturbed by the door motion because 1 the detection field is crossed by the door 1 Incr
2. 2 2009 Designed to be flush mounted Dimensions 140mm L x 38mm W x 55mm D Weight 0 1kg Material PC Color of housing Black smoked Length of cable 1 m total compliant with DIN5510 Manual adjustments e Sensitivity by push buttons e Input voltage 10V 24V DC e Shape of detection field by push buttons e Input current lt 10mA at 24V e Tilt angle mechanically Hold time 0 5s to 10s adjustable Remote control adjustments LED Red and orange LED e Sensitivity 4 levels Degree of protection IP41 e Hold time From 0 5s to 10s in 10 steps Temperature range 25 C to 55 C e Shape of detection field Choice of 9 pre programmed fields e Max presence time e Security 20s to 25min in 10 steps 4 digit entry code Wiring GREY Relay NC YELLOW Relay NO DESCRIPTION WHITE Relay COM GREEN Power Supply BROWN Power Supply After power on the sensor launches a setup for a few seconds It is advisable to stay out of the field to finish the setup successfully LED Tilt angle adjustment Push button B IR Receiver Push button A To adjust the tilt angle of the optical bloc use the small pin delivered with the product see figure above insert it into the tilt angle adjustment slit see figure above and adjust the angle from 0 to 20 in steps of 5 At 2m high with all the 15 spots on the sensing fields are as follows Angle 0 Sensing field 100cm W x 100c
3. If no button has been pressed within 1 minute the adjustment session is automatically closed y HALMA COMPANY 1 4 CONFIGURATION 1 INSERTION OF BATTERIES WITH REMOTE e Open the battery compartment e Insert two AAA batteries as shown e Close the battery compartment CONTROL 2 REMOTE CONTROL OPERATION 10 Monitoring 0 9 Number keys 1 11 Detection field configuration 12 Not used Not used 2 13 Pulse frequency 14 Door control le 15 Check Values Unlock 4 16 Lock Minus 5 Holdtime 6 17 Not used 7 18 Not used 8 19 Not used 9 20 Remark For optimum results point the remote control vertically to the front of the sensor before pressing its buttons The sensor can be adjusted with its cover from a distance up to 2m 3 CONFIGURATION OF THE SENSOR Every adjustment session using the infrared remote control must start with unlocking and end in locking The table below lists the parameters able to be adjusted by remote control and the operations required in order to adjust these parameters PARAMETERS OPERATIONS LED SIGNAL UNLOCK Press the UNLOCK key 4 The red LED flashes quickly waiting for the access Enter your 4 digit access code using NUMBER keys 0 9 1 code Press only the UNLOCK key 4 no code required After entering the correct code or if no code is e during the first sensor adjustment required the red LED flashes slowly to indicate that e if the access code i
4. RS 15 SENSORIO sensors and more USER S GUIDE UNIVERSAL MOTION AND PRESENCE SENSOR FOR AUTOMATIC DOORS The RS 15 is a sensor developed to equip automatic inner doors in high speed trains The RS 15 has two functions it detects motion to give an Opening signal and presence to prevent the door from closing on a stationary person within the presence detection zone It has been designed to be flush mounted TECHNICAL SPECIFICATIONS Focused active infrared with microprocessor 15 independent IR spots producing a square shaped detection field Mounting height max 25m Tilt angles 0 to 20 step 5 Detection area mounting i 2m angle 20 im W x 4 2 m D 130 mm diameter Motion and presence Technology Optical features Spot dimension typical Detection mode Reaction time lt 100ms Supply voltage 12V to 30V AC 10 12V to 45V DC 10 Mains frequency 50 to 60 Hz Power consumption lt 3W VA Output relay free of potential change over contact e Max contact voltage 42V AC 60V DC e Max contact current 1A resistive e Max switching power 30W DC 60VA AC Monitoring input optocoupled Nee of potential Connections e Presence sensor side Integrated 7 pin connector on sensor side unpluggable Mounting Norms and conformity e Presence sensor without cable o EMC 2004 108 EEC o EN 50155 DIN 5510 2 2009 NF F16 102 1992 CEN TS 45545 2 2009 e Presence sensor cable DIN 5510
5. d to avoid interferences aa select the desired frequency between sensors if their respective sensing fields are overlapping In that case choose different frequencies for 1 Low the sensors 2 Mid 3 High PULSE FREQUENCY E Press the OUTPUT CONFIGURATION key 17 Use the NUMBER keys 1 2 to select the required output configuration Active Passive c Hn a KO a thd 4 Detection dinka COND No Detection COMBI co Mae DOOR CONTROL Press the DOOR CONTROL key 14 Use the NUMBER keys 1 3 to select IN door permanently open mode the sensor is OUTPUT CONFIGURATION the required door operating mode continuously detecting The red LED is continuously ON 1 door automatic mode In door permanently closed mode the sensor is in 2 door permanently open standby It detects nothing anymore and the LED is 3 door permanently closed continuously OFF DOOR CONTROL MAXIMUM Press the MAXIMUM DURATION OF PRESENCE DETECTION key 18 The sensor will integrate the new environment and return DURATION OF Use the NUMBER keys 0 9 to select the required duration to no detection State if detection has exceeded the PRESENCE selected time DETECTION 0 20 seconds minutes 12 1 minute minutes 2 2 minutes minutes 3 3 minutes minutes 4 5 minutes minutes MAXIMUM DURATION Ua Press the SETUP key 19 followed by the NUMBER key 0 to launch a 0 setup of the sensor SETUP o 3 4
6. ease the tilt angle of the sensor L leave s 8 2 of the vibrations caused by the door 2 Ensure the sensor is fastened correctly E movement Two sensors in close proximity are The sensing fields are overlapping Choose a different pulse frequency for the sensors ex D disturbing each other sensor 1 LOW sensor 2 MID x The sensor does not respond to the 1 Batteries in remote control are dead or 1 Check to insure that the batteries are installed 3 remote control installed improperly correctly eventually replace batteries 53 2 Remote control is badly pointed 2 Point the remote control vertically to the sensor 3 The sensor is doing a setup 3 Cut and restore power supply and wait outside of the E detection field until the setup is finished few seconds E The sensor does not unlock when the Improper code being entered Cut and restore power supply No code is required to lS access code is entered unlock during the first minute after powering Press on ies unlock then on lock and introduce a new access fore O og code i S The red LED flashes quickly Sensor goes into a security mode afteran Replace sensor lt 2 flashes sec internal sensor test failed t SENSORIO a division of BEA SA LIEGE Science Park all e des Noisetiers 5 4031 Angleur BELGIUM g 5 T 32 4 361 65 89 F 32 4 361 28 58 info sensorio be www sensorio be 4 4
7. m D Angle 20 Sensing field 100cm W x 120cm D TILT ANGLE ADJUSTMENT Without remote control you can set two parameters using the push buttons the sensitivity from 1 to 4 and the detection field from CONFIGURATION 1 to 9 See figure above for the location of the push buttons and the pin to activate the buttons WITH To set the sensitivity PUSH BUTTONS 1 Press button A once to enter into an adjustment session for the parameter sensitivity The RED LED now flashes The number of flashes indicates the current sensitivity setting 2 Press button A again to increment the sensitivity The RED LED indicates the current sensitivity setting If you reach the value 4 and press button A again the sensitivity will be 1 rolling value system 3 If you reached the required sensitivity value press button B to close the adjustment session To set the detection field 1 Press button B once to enter into an adjustment session for the parameter detection field The ORANGE LED now flashes The number of flashes indicates the currently selected detection field see page 2 2 Press button B again to go to the next detection field The ORANGE LED indicates the currently selected field If you reach the value 9 and press button B again you will go back to detection field number 1 rolling value system 3 If you reached the required detection field press button A to close the adjustment session
8. of the LED the sensitivity is set to the value 4 CHECK VALUES c PLUS MINUS Press the key corresponding to the parameter to be modified SENSITIVITY or HOLD TIME and then press the PLUS key 2 or MINUS key 4 to increase reduce the value by 1 unit PLUS MINUS amp or Mal Note about LED signal The LED flashes quickly waiting for the value Once this has been entered it flashes slowly again PARAMETERS OPERATIONS Definitions Advices AAS A Press the SENSITIVITY key 20 Use the NUMBER keys 1 4 to enter the required sensitivity motion and safety SENSITIVITY Press the HOLD TIME key 6 Use the NUMBER keys 0 9 to enter the The hold time allows extended output activation time after required hold time 0 5s to 9 s detection has stopped It is recommended to use this ATN parameter instead of the operator s one with the same HOLD TIME x O function interferences with the sensor DETECTION Press the DETECTION FIELD key 11 Use the NUMBER keys 1 9 to The detection pattern is made of 15 independent spots FIELD select the desired detection field according to the table on the next page Organized in 3 ranges of 5 spots parallel to the door Each spot can be individually switched on or off set to DETECTION FIELD x detect either motion or presence See next page field detection PULSE Press the PULSE FREQUENCY key 13 Use the NUMBER keys 1 3to The pulse frequency is use
9. s reset to the 0000 value factory setting the unlock was successful and the adjustment e during the first minute after the power on session has begun UNLOCK with code E o 9 Note lt Adjustment session ON UNLOCK without code The red LED stops flashing and returns to its normal function LOCK When all the parameters have been set press the LOCK key 10 If you wish to enter a new access code use NUMBER keys 0 9 1 to enter the new 4 digit code within 1 minute If no access code is entered or if you want to keep the current access code press the LOCK key 16 once more If no remote control key is pressed within 1 minute the adjustment session is automatically locked LOCK with code change e o o 0 9 LOCK without code or code change 2 4 Note amp All parameters or functions listed in the following tables are only accessible if the sensor is in adjustment session The red LED is then slowly flashing During an adjustment session each parameter may be checked or changed at any time in the following way PARAMETERS OPERATIONS CHECK VALUES Press the key corresponding to the parameter to be checked and then press the CHECK VALUES key al Count the number of times the LED flashes which corresponds to the value of the checked parameter No LED flash corresponds to the value 0 Repeat this operation to check the value of the other parameters if required i Example SENSITIVITY key 4 flashes