1. 7 LOC PG DESCRIPTION DEFAULT YOUR DATA 243 12 PROGRAMMING THE ZONES Seg1 Door Shunt Zone 0 Disabled Seg2 Request to Exit RTE 0 Disabled 244 13 READER TIMES Seg1 Scan Time 1 100 seconds 100 1 second Seg2 Relay Active Time seconds 10 10 seconds Seg 3 Door Fault Warning Time seconds 30 30 seconds Seg4 Door Fault Alarm Time seconds 0 0 seconds 245 13 RESET THE READER ADDRESS A Entering a 0 will reset and cause the reader to cease functioning 246 13 PROGRAMMING THE ACCESS OPTIONS Seg1 DOOR OPTIONS 1 On if locking mechanism is a Maglock or Drop Bolt 2 On if access is allowed regardless of Armed status of the system 3 On if the door is not to be latched unlocked during an open schedule 4 On if onboard open collector output only triggers during an open schedule 5 On if onboard open collector output only triggers during a close schedule 6 On if Forced Entry Alarm is logged 7 On if access allowed without an RTE 8 On if relay operates normally during off schedule Seg 2 SCHEDULES FOR ONBOARD OPEN COLLECTOR OUTPUT On if driver follows Schedule 1 On if driver follows Schedule 2 On if driver follows Schedule 3 On if driver follows Schedule 4 On if driver follows Schedule 5 On if driver follows Schedule 6 On if driver follows Schedule 7 On if driver follows Schedule 8 Seg 3 MORE DOOR OPTIONS 1 O
2. LED1 On if driver follows Schedule 1 LED2 On if driver follows Schedule 2 LEDS On if driver follows Schedule 3 LED4 On if driver follows Schedule 4 LED5 On if driver follows Schedule 5 LED6 On if driver follows Schedule 6 LED7 On if driver follows Schedule 7 LED8 On if driver follows Schedule 8 NX 1701E Installation manual Page 13 31 01 05 Networ Segment 3 More Door Options LED1 On if egress input is to be disabled LED2 Reserved LEDS Reserved LED4 Reserved LED5 Reserved LED6 Reserved LED7 Reserved LED8 Reserved Location 247 Programming the Opening Time for Schedule 1 2 segments of numerical data Segment 1 Program the hour of the opening time in 24 hour format Default is 8 8 00 AM Segment 2 Program the minutes after the hour of the opening time for Schedule 1 Default is 0 Location 248 Programming the Closing Time for Schedule 1 2 segments of numerical data Segment 1 Program the hour of the closing time in 24 hour format Default is 20 8 00 PM Segment 2 Program the minutes after the hour of the closing time for Schedule 1 Default is 0 Location 249 Programming the Days for Schedule 1 1 segment of binary data LED1 On if schedule is active on Sunday LED2 On if schedule is active on Monday LED3 On if schedule is active on Tuesday LED4 On if schedule is active on Wednesday LED5 On if schedule is active on Thursday LE
3. 8 segments of numerical data Program the day of the month in January that the Opening time in a schedule is suppressed For example if the opening should not occur on January 1 program a 1 in Segment 1 This feature can be repeated up to a maximum of 8 holidays per location month Default is No holidays Locations 272 282 Programming the Date of Holidays from February to December 8 segments of numerical data Locations 272 282 are used to program the day of each month from February to December in which the Opening time in a schedule is suppressed Each location will accommodate up to a maximum of 8 holidays and programmed with the same steps as Location 271 described previously Location 272 February holidays Location 273 March holidays Location 274 April holidays Location 275 May holidays Location 276 June holidays Location 277 July holidays Location 278 August holidays Location 279 September holidays Location 280 October holidays Location 281 November holidays Location 282 December holidays Location 283 Programming Activation Data for User Cards 1 through 120 15 segments of binary data This location is used to select which user cards 1 through 120 are activated If the LED is on the card is active Each segment has 8 LEDs corresponding to the 8 possible user cards Example Segment 4 LED 2 indicates that user card 26 is active LED1
4. On if schedule is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is active on Saturday 8 On if schedule is disabled on holidays 253 14 OPENING TIME FOR SCHEDULE 3 Seg1 Hour of Opening Time 24 hr format 8 8AM Seg2 Minutes after Hour of Opening 0 254 14 CLOSING TIME FOR SCHEDULE 3 Seg1 Hour of Closing Time 24 hr format 20 8 PM Seg2 Minutes after Hour of Closing 0 255 14 DAYS FOR SCHEDULE 3 1 On if schedule is active on Sunday 2 On if schedule is active on Monday 3 On if schedule is active on Tuesday 4 On if schedule is active on Wednesday 5 On if schedule is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is active on Saturday 8 On if schedule is disabled on holidays 256 14 OPENING TIME FOR SCHEDULE 4 Seg1 Hour of Opening Time 24 hr format 8 8AM Seg2 Minutes after Hour of Opening 0 257 14 CLOSING TIME FOR SCHEDULE 4 Seg1 Hour of Closing Time 24 hr format 20 8 PM Seg2 Minutes after Hour of Closing 0 NX 1701E Installation manual Page 19 31 01 05 RNietwo 9 LOC PG DESCRIPTION DEFAULT YOUR DATA 258 14 DAYS FOR SCHEDULE 4 1 On if schedule is active on Sunday 2 On if schedule is active on Monday 3 On if schedule is active on Tuesday 4 On if
5. Card 1 Segment 1 User Cards 1 8 Segment 9 User Cards 65 72 LED2 Card 2 Segment 2 User Cards 9 16 Segment 10 User Cards 73 80 LED3 Card 3 Segment 3 User Cards 17 24 Segment 11 User Cards 81 88 LED4 Card 4 Segment 4 User Cards 25 32 Segment 12 User Cards 89 96 LEDS Card 5 Segment 5 User Cards 33 40 Segment 13 User Cards 97 104 LEDE Card 6 Segment 6 User Cards 41 48 Segment 14 User Cards 105 112 LED Card 7 Segment 7 User Cards 49 56 Segment 15 User Cards 113 120 Er rer Segment 8 User Cards 57 64 Location 284 Programming Activation Data for User Cards 121 through 240 15 segments of binary data This location is used to select which user cards 121 through 240 are activated If the LED is on the card is active Each segment has 8 LEDs corresponding to the 8 possible user cards Example Segment 15 LED 8 indicates that user card 240 is active LED1 Card 1 Segment 1 User Cards 121 128 Segment 9 User Cards 185 192 LED2 Card 2 Segment 2 User Cards 129 136 Segment 10 User Cards 193 200 LED3 Card 3 Segment 3 User Cards 137 144 Segment 11 User Cards 201 208 LED4 Card 4 Segment 4 User Cards 145 152 Segment 12 User Cards 209 216 LEDS Card 5 Segment 5 User Cards 153 160 Segment 13 User Cards 217 224 LEDE Card 6 Segment 6 User Cards 161 168 Segment 14 User Cards 225 232 LED Card 7 Segment 7 User Cards 169 176 Seg
6. On gt Location 243 Segment 2 must be programmed with a valid zone number for the RTE to be sent Segment 2 Double Scan Function Double Beep Program the functions that are performed when a card is scanned twice within the 2 Scan Hold Time two beeps Location 244 Segment 1 programs the length of time between beeps The descriptions of the options are the same as for Single Beep Scan Function Default is 1 Segment 3 Single Scan Hold Function Triple Beep Program the functions that are performed when a card is scanned and held at the reader for the duration of the 2 Scan Hold Time three beeps Location 244 Segment 1 programs the length of time between beeps The descriptions of the options are the same as for Single Beep Scan Function Default is 1 Locations 1 240 Reserved Location 241 Programming the X 10 Address for the Scan Functions 5 segments of numerical data Segment 1 Program a number from 0 15 to represent the corresponding X 10 Module Number from the following table Default is 0 Module 1 2 3 4 5 6 7 8 9 10 11 12 15 segi_ 0 1 2 3 4 5 6 7 8 9 10 11 14 NX 1701E Installation manual Page 10 31 01 05 Networ G Segment 2 Program a number from 0 15 to represent the corresponding X 10 House code from the following table Default is 0 Segment 3 programmed if Location 0 Segment 1 Option 7 is set Use the following table Default is 2 7 Single Scan Function Single Beep Program t
7. SCAN HOLD FUNCTION 3 Beep 2 0 All units off 1 All lights on 2 On 3 Off 4 Dim 5 Bright 6 Alllights off 242 11 OPTIONS AND READER PARTITION Seg1 SYSTEM OPTIONS 3 5 6 1 On if enabled for User Card Programming 2 On if optical tamper enabled 3 On if buzzer follows keypad buzzing 4 On if ding dong chime enabled Opt 3 amp chime must be enabled 5 On if an RTE from a scanned card is to be logged as Code Entry 6 On if reader is in NX 1701E Legacy Mode 7 On if an RTE from a zone or the Egress input is to be logged as Code Entry 8 On if LEDs to extinguish after 2 minutes without a scan Seg 2 LED1 GREEN OPTIONS 1 2 1 On follows system Ready status 2 On to toggle with the Open Collector output 3 On if inverted 4 Reserved 5 Reserved 6 Reserved 7 Reserved 8 Reserved Seg3 LED2 RED OPTIONS 1 1 On follows system Armed status 2 On to toggle with the Open Collector output 3 On if inverted 4 Reserved 5 Reserved 6 Reserved 7 Reserved Reserved Seg4 READER PARTITION 1 2 3 4 5 6 7 8 1 On if reader is in Partition 1 2 On if reader is in Partition 2 3 On if reader is in Partition 3 4 On if reader is in Partition 4 5 On if reader is in Partition 5 6 On if reader is in Partition 6 7 On if reader is in Partition 7 8 On if reader is in Partition 8 NX 1701E Installation manual Page 17 31 01 05 Networ G
8. a aa erage n 25 NX 1701E Installation manual Page 3 31 01 05 Networ i GENERAL DESCRIPTION The Networx NX 1701E is a proximity card reader door control module used to expand the capabilities of the Networx control panels e Microprocessor controlled e Includes one 1 low current trigger output which can be used to control a door strike relay e Upto 15 card readers can be connected to the NX 8E and Nx 8 3 card readers can be connected to the NX 6 and 2 card readers can be connected to the Nx 4 Flash panels only e Can be programmed to control access in any or all partitions e LEDs can be programmed to follow the output and or the armed or ready status of the system e Has an optional optical tamper switch INSTALLATION AND WIRING To install the card reader simply wire it into the system Refer to the following wiring table for details DESCRIPTION GREEN Connect to the Networx control panel DATA terminal This wire is the data signaling BLACK Connect to the Networx control panel COMMON terminal Supplies the common side of RED Connect to Networx control panel AUX POWER terminal Supplies power to the card WHITE This is an optional EGRESS exit input To use this feature connect the normally open EGRESS 9 eSS switch between this terminal and COM If this feature is not used there is no need to connect this wire This is an optional open collector negative trigger OUTPUT It can be used to drive a relay To u
9. a card reader is similar to modifying user codes at a keypad MUST BE A MASTER USER IN ORDER TO MODIFY USER CARD INFORMATION ACTION RESULT CF K icra eae Accesses Code Programming lt master code rereset If the code is valid the Ready LED will flash Factory Default is 1 2 O User Number 2 is used to program user cards so oP my Trent AEs Unit is now ready for you to choose one of the User O iine control is an nx 8 Card Programming modes as if user code 2 da 2 if the control is an NX 8E 1 Add One User 2 Add Multiple Users w Auto Increment 3 Activate Single User 4 De activate One User 5 Delete Reset One User IMPORTANT NOTE Adding or de activating user cards from a reader will cause the code for User Number 2 to become invalid Therefore it will need to be re entered after all user cards are programmed into the readers NX 1701E Installation manual Page 7 31 01 05 Networ PO Adding One User ACTION RESULT stay 7 3 digit user number Example if 4 digit user code or O O if 6 digit user codes Scan the card designated for the user entered in the previous step Adding Multiple Users with Auto Increment Accesses Activation mode If a valid user number is entered LED1 on any enabled readers will begin to flash 1 If the user card is not already in the system it will be added and mapped to the entered user number 2 Ifthe card is already in the system
10. is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is active on Saturday 8 On if schedule is disabled on holidays 271 15 HOLIDAYS IN JANUARY 8 max No holidays gt 272 15 HOLIDAYS IN FEBRUARY 8 max No holidays _ _____ _ _ 273 15 HOLIDAYS IN MARCH 8 max Noholidays _ _ 274 15 HOLIDAYS IN APRIL 8 max No holidays gt 275 15 HOLIDAYS IN MAY 8 max No holidays _ ___ __ 276 15 HOLIDAYS IN JUNE 8 max No holidays _ ___ __ _ _ 277 15 HOLIDAYS IN JULY 8 max Noholidays _ ____ _ 278 15 HOLIDAYS IN AUGUST 8 max No holidays gt 279 15 HOLIDAYS IN SEPTEMBER 8 max No holidays _ ___ _ _ _ _ 280 15 HOLIDAYS IN OCTOBER 8 max No holidays _ ___ __ _ _ 281 15 HOLIDAYS IN NOVEMBER 8 max No holidays gt 282 15 HOLIDAYS IN DECEMBER 8 max No holidays _ _____ _ _ 283 15 ACTIVATION DATA FOR USER CARDS 1 120 1 User Cards 1 8 2 User Cards 9 16 3 User Cards 17 24 4 User Cards 25 32 5 User Cards 33 40 6 User Cards 41 48 7 User Cards 49 56 8 User Cards 57 64 9 User Cards 65 72 10 User Cards 73 80 11 User Cards 81 88 12 User Cards 89 96 13 User Cards 97 104 14 User Cards 105 112 15 User Cards 113 120 NX 1701E Installation manual Page 21 31 01 05 KG Networ LOC PG DESCRIPTION DEFAULT YOUR DATA 284 15 ACTI
11. is entered the desired function will be performed on the user associated with the card scanned NX 1701E Installation manual Page 9 31 01 05 Networ PO PROGRAMMING LOCATIONS SCAN METHODS Legacy mode is default Alternative mode is shown below in brackets Refer to Location 242 Segment 1 on page 11 and the Glossary on page 23 for explanation Location 0 Programming the Scan Functions 3 segments of binary data Location 0 is used to select the particular function s that are activated when a card is scanned More than one function may be selected If more than one function is selected they will execute in order from function 1 to function 8 Functions 1 6 will be performed based on the user s authority as programmed by the gt 6 function refer to keypad user manual Segment 1 Single Scan Function Single Beep Program the functions that are performed when a card is scanned one beep LED1 On to send Code Entry function to the control panel LED2 On to activate the Armed Away mode LEDS On to activate the Armed Stay mode LED4 On to send the Disarm function to the control panel LED5 On to send Auxiliary Function 1 to the control panel LED6 On to send Auxiliary Function 2 to the control panel LED7 On to broadcast an X 10 function see Location 241 for programming LED8 On to send a Request To Exit RTE and activate the onboard open collector output Default is
12. schedule is active on Wednesday 5 On if schedule is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is active on Saturday 8 On if schedule is disabled on holidays 259 14 OPENING TIME FOR SCHEDULE 5 Seg1 Hour of Opening Time 24 hr format 8 8AM Seg2 Minutes after Hour of Opening 0 260 14 CLOSING TIME FOR SCHEDULE 5 Seg1 Hour of Closing Time 24 hr format 20 8 PM Seg2 Minutes after Hour of Closing 0 261 14 DAYS FOR SCHEDULE 5 1 On if schedule is active on Sunday 2 On if schedule is active on Monday 3 On if schedule is active on Tuesday 4 On if schedule is active on Wednesday 5 On if schedule is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is active on Saturday 8 On if schedule is disabled on holidays 262 14 OPENING TIME FOR SCHEDULE 6 Seg1 Hour of Opening Time 24 hr format 8 8AM Seg2 Minutes after Hour of Opening 0 263 14 CLOSING TIME FOR SCHEDULE 6 Seg1 Hour of Closing Time 24 hr format 20 8 PM Seg2 Minutes after Hour of Closing 0 264 14 DAYS FOR SCHEDULE 6 1 On if schedule is active on Sunday 2 On if schedule is active on Monday 3 On if schedule is active on Tuesday 4 On if schedule is active on Wednesday 5 On if schedule is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is a
13. D6 On if schedule is active on Friday LED7 On if schedule is active on Saturday LED8 On if schedule is disabled on holidays Locations 250 270 Programming the Schedules 2 8 Locations 250 270 are used to program the opening times closing times and days for Schedules 2 8 Each schedule has three locations that are programmed with the same steps as Schedule 1 described previously Refer to Schedule 1 Locations 247 249 above for specific instructions Location 250 Opening Time for Schedule 2 Location 262 Opening Time for Schedule 6 Location 251 Closing Time for Schedule 2 Location 263 Closing Time for Schedule 6 Location 252 Days for Schedule 2 Location 264 Days for Schedule 6 Location 253 Opening Time for Schedule 3 Location 265 Opening Time for Schedule 7 Location 254 Closing Time for Schedule 3 Location 266 Closing Time for Schedule 7 Location 255 Days for Schedule 3 Location 267 Days for Schedule 7 Location 256 Opening Time for Schedule 4 Location 268 Opening Time for Schedule 8 Location 257 Closing Time for Schedule 4 Location 269 Closing Time for Schedule 8 Location 258 Days for Schedule 4 Location 270 Days for Schedule 8 Location 259 Opening Time for Schedule 5 Location 260 Closing Time for Schedule 5 Location 261 Days for Schedule 5 NX 1701E Installation manual Page 14 31 01 05 Networ Location 271 Programming the Date of Holidays in January
14. Networx Series NX 1701E Proximity Card Reader Installation manual imagination at work Networ These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to be met during installation operation and maintenance If further information is desired or if particular problems arise that are not covered sufficiently for the purchaser s purpose the matter should be referred to GE Security Gladewater Texas USA This document contains proprietary information of GE Security USA and is furnished to its customer solely to assist that customer in the installation testing operations and or maintenance of the equipment described This document shall not be reproduced in whole or in part nor shall its contents be disclosed to any third party without the written approval of GE Security Networx is a trademark of the GE Security companies Symbol Legend L Warning A Caution BS Note Tip co Enter NxX 1701E Installation manual Indicates a procedure practice condition or statement that if not strictly observed could result in personal injury This symbol indicates electrical warnings and cautions Indicates a procedure practice condition or statement that if not strictly observed could result in damage to or destruction of equipment or property This symbol indicates general warnings and cautions Indicates an essential or importa
15. ON 2 45 PFOGFAIMMING ENC ZOMCS si uuina r T Nr Mdicenbed et hs ctr Seo Location 244 Programming the Various Reader TiMers ccccsscsssssssssssssscsssssssssssssssscsssssssssssssssesssssssssssssseecsssssssssessseseessessusssesseeeees Location 245 Resetting the Reader Address ses Location 246 Programming the ACCESS OPtiOns vccecccssssssssssssssscsssssssssssssssssssssssssssssssessssssssssssssssesssssssssssssseesssssssssssessseessssssssssessseeees Location 247 Programming the Opening Time for Schedule 1 Location 248 Programming the Closing Time for Schedule 1 Location 249 Programming the Days for Schedule 1 eeccccssssssssssssssssssscssssssssssssssesssssssssssssssessssssssssssssssessssssssssssssssessssssusseesseesees Locations 250 270 Programming the Schedules 2 B ceccccsscssssssssssssssssssssssssssssssessssssssssssssssesssssssssssssssecsssssusssssssseesssessssssesseesees Location 271 Programming the Date of Holidays in JaNUAr yes Locations 272 282 Programming the Date of Holidays from February to December G Location 283 Programming Activation Data for User Cards 1 through 120 wkd Location 284 Programming Activation Data for User Cards 121 through 240 week Location 265 Code Emtrip T0 aiT PONI aaa E E N ATE oo rer ende 15 PROGRAMMING WORKSHEETS ssri ii o na a aaa n a a at aain 16 GEOSSARY AOE EA EE S E A SE 23 SPECIFICATIONS irena a ae te anne sony a a a a es a aa a E 24 DECLARATION OF CONFORMI Perinera a a a a een a eee
16. S MANUFACTURERS DECLARATION OF CONFORMITY For NX 1701E BOM revision level 11 June 2003 5157D Smart card reader GE Interlogix Caddx GE Interlogix PTY LTD 646 Whitehorse Road Mitcham 3132 Australia GE Interlogix B V Kelvinstraat 7 6003 DH Weert The Netherlands Concerning RTTE EMC Safety Radio A sample of the product has been tested by Underwriters Laboratories Inc Test report reference GE ILX CE_qualification_plan CEQP_NXCS 1700 Report NC4364 081403 BP9453 A2 Report NC4364 081403 Project No 03CA26086 Project No 03CA26086 Applied standards EN50130 4 1995 EN60950 2000 EN300330 2 v1 1 1 06 2001 A1 1998 IEC60950 1999 3 rd Ed Not Applicable Means of conformity Equipment class identifier RF products falling under the scope of R amp TTE None class 1 product X class 2 product We declare under our sole responsibility that this product is in conformity with Directive 93 68 EEC Marking and or complies to the essential requirements and all other relevant provisions of the 1999 5 EC R amp TTE based on test results using harmonized standards in accordance with the Directives mentioned NX 1701E Installation manual Page 25 31 01 05 Approved in Permis en Toegestaan in Permesso in Austria x Iceland x Norway x Belgium x Ireland Xx Portugal x Denmark x Italy x
17. Spain Xx Finland Liechtenstein x Sweden x France X Luxembourg Switzerland X Germany x Netherlands x United Kingdom Greece CE www gesecurity com EMEA Distribution is a division of GE Security EMEA bvba COPYRIGHT 2005 GE Security EMEA bvba All rights reserved GE Security EMEA bvba grants the right to reprint this manual for internal use only GE Security EMEA bvba reserves the right to change information without notice
18. VATION DATA FOR USER CARDS 121 240 User Cards 121 128 User Cards 129 136 User Cards 137 144 LEDI Card 1 User Cards 145 152 LED2 Card 2 User Cards 153 160 LED3 Card 3 User Cards 161 168 LED4 Card 4 User Cards 169 176 FR care z E Car User Cards 177 184 BEDE Cae 10 User Cards 193 200 11 User Cards 201 208 12 User Cards 209 216 13 User Cards 217 224 14 User Cards 225 232 15 User Cards 233 240 285 15 CODE ENTRY LOGGING PARTITION 0 NX 1701E Installation manual Page 22 31 01 05 Networ PO GLOSSARY TERM DESCRIPTION Alternative Mode Alternative mode is an optional scan method as opposed to the default Legacy mode see below The card is to be continuously held at the reader for a specified number of beeps Example Hold the card at the card reader s sensor for a total of 2 beeps This is a double beep in the alternative mode This method becomes available when Location 272 Segment 1 Option 6 is disabled Double Beep An audible indicator beep beep Double Beep Scan When a user card is scanned and held at the reader for 2 beeps the reader will perform the functions as programmed in Location 241 Segment 4 Legacy Mode Legacy mode is used to describe the default operation of the card reader s scanning method This mode uses the same scan methods as prior versions of the card reader modules Example Pass a user card by the reader
19. ame as the aforementioned LED keypad The LCD keypad display will prompt you for the data required While in the programming mode and not in a location the number in parenthesis is the location you were previously changing For example if the display reads Enter location then 5 it is reminding you that location 5 was the last location you programmed In feature selection data the numbers of the enabled features will be displayed The features not enabled will display a hyphen PROGRAMMING DATA TYPES Numerical Data Numerical data can take on values from 0 255 or 0 15 depending on the segment size Feature Selection Feature selection data is used to turn features on or off USER CARDS Adding and de activating users is done through a combination of entering information at the keypad and scanning cards Before a card can be entered one reader on the system must be programmed with User Card Programming enabled Location 242 Segment 1 Option 1 page 11 EN It is recommended that only one reader on the system be enabled to modify user cards and that this reader be located near a keypad This reader will transfer information to all other readers in the system once programming is finished Once a reader is enabled to modify users it must be placed into one of the following five modes 1 Add One User 2 Add Multiple Users w Auto Increment 3 Activate One User 4 De Activate One User 5 Delete Reset One User Modifying users on
20. ctive on Saturday 8 On if schedule is disabled on holidays 265 14 OPENING TIME FOR SCHEDULE 7 Seg1 Hour of Opening Time 24 hr format 8 8AM Seg2 Minutes after Hour of Opening 0 266 14 CLOSING TIME FOR SCHEDULE 7 Seg1 Hour of Closing Time 24 hr format 20 8 PM Seg2 Minutes after Hour of Closing 0 NX 1701E Installation manual Page 20 31 01 05 RNietwo ex rr X Kole PG DESCRIPTION DEFAULT YOUR DATA 267 14 DAYS FOR SCHEDULE 7 1 On if schedule is active on Sunday 2 On if schedule is active on Monday 3 On if schedule is active on Tuesday 4 On if schedule is active on Wednesday 5 On if schedule is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is active on Saturday 8 On if schedule is disabled on holidays 268 14 OPENING TIME FOR SCHEDULE 8 Seg1 Hour of Opening Time 24 hr format 8 8AM Seg2 Minutes after Hour of Opening 0 269 14 CLOSING TIME FOR SCHEDULE 8 Seg1 Hour of Closing Time 24 hr format 20 8 PM Seg2 Minutes after Hour of Closing 0 270 14 DAYS FOR SCHEDULE 8 1 On if schedule is active on Sunday 2 On if schedule is active on Monday 3 On if schedule is active on Tuesday 4 On if schedule is active on Wednesday 5 On if schedule
21. dy status of system Default is On LED2 On to toggle with the open collector output activation Default is On LED3 On if inverted LED4 Reserved LED5 Reserved LED6 Reserved LED7 Reserved LED8 Reserved Segment 3 LED2 Red Options LED1 On to follow Armed status of system Default is On LED2 On to toggle with the open collector output activation LED3 On if inverted LED4 Reserved LED5 Reserved LED6 Reserved LED7 Reserved LED8 Reserved Segment 4 Reader Partition LED1 On if reader is in Partition 1 Default is On LED2 On if reader is in Partition 2 Default is On LED3 On if reader is in Partition 3 Default is On LED4 On if reader is in Partition 4 Default is On LED5 On if reader is in Partition 5 Default is On LED6 On if reader is in Partition 6 Default is On LED7 On if reader is in Partition 7 Default is On LED8 On if reader is in Partition 8 Default is On Location 243 Programming the Zones 2 segments of numerical data Segment 1 Door Shunt Zone Program the zone that will be monitored as a door for access control This location must be programmed with a valid zone for monitored access control functions to work properly Default is 0 Additionally this zone must be configured in the control panel as an access control zone by programming an unused Zone Type C
22. h If the location is valid the Armed LED will extinguish the Ready LED will illuminate and the zone LED s will show the data for the first segment of this location To Change Location Data or changed data suet veers es The Ready LED will flash to indicate a data change in process and will continue until the data is saved CF pet in DRE The new data is saved The keypad will increment and display the next segment s data NOTE Repeat these steps until the last segment is reached To Exit a Location CP sees a Exits from this location The Ready LED will extinguish The Armed LED will illuminate waiting for a new programming location to be entered To Review The Data CP location HF j j etsers The Armed LED will flash If the location is valid the Armed LED will extinguish the Ready LED will illuminate and the zone LED s will show the data for the first segment of this location or Aa 2 Do not enter data The next segment is displayed Each time is pressed the data of the next segment will be displayed for review Shortcuts i s oe 9 Previous location CP sk same location CP S Next sequential location Exiting the Program Mode CF EXIT EXIT ree renee Exits this programming level NX 1701E Installation manual Page 6 31 01 05 Networ i USING THE LCD KEYPAD All steps required for programming are the s
23. haracteristic in locations 111 169 Seg 4 Opt 4 Segment 2 Request To Exit RTE Zone Program the zone that will be monitored to signal an RTE If this segment is programmed with a valid zone and the zone is faulted the reader will activate its onboard open collector output and send the RTE Default is 0 Additionally this zone must be configured in the control panel as an RTE zone by programming an unused Zone Type Characteristic in locations 111 169 Seg 4 Opt 3 NX 1701E Installation manual Page 12 31 01 05 Networ Location 244 Programming the Various Reader Timers 4 segment of numerical data Segment 1 Scan Time Enter the amount of time required to hold a card between beeps to activate the functions programmed in Location 0 Segments 2 and 3 This timer is timed in 1 100 second increments from 0 to 2 55 seconds Default is 100 1 second Segment 2 Relay Active Time Enter the amount of time the onboard open collector output is energized once activated This timer is timed in 1 second increments from 0 to 255 seconds Default is 10 10 seconds Segment 3 Door Fault Warning Time Enter the amount of time a monitored zone see Location 243 Segment 1 must be faulted before sounding a warning local buzzer The door fault warning is timed in 1 second increments from 0 to 255 seconds Default is 30 30 seconds Segment 4 Door Fault Alarm Time Enter the amount of time a monitored zone see Location 243 Seg
24. he Armed Away mode 3 On to activate the Armed Stay mode 4 On to send the Disarm function to the control panel 5 On to send Auxiliary Function 1 to the control panel 6 On to send Auxiliary Function 2 to the control panel 7 On to broadcast an X 10 function Loc 241 for programming 8 On to send an RTE and activate the onboard open collector output Seg3 SINGLE SCAN HOLD FUNCTION 3beep 1 1 On to send Code Entry function to the control panel 2 On to activate the Armed Away mode 3 On to activate the Armed Stay mode 4 On to send the Disarm function to the control panel 5 On to send Auxiliary Function 1 to the control panel 6 On to send Auxiliary Function 2 to the control panel 7 On to broadcast an X 10 function Loc 241 for programming 8 On to send an RTE and activate the onboard open collector output 1 240 10 RESERVED 241 10 X 10 ADDRESS Seg1 MODULE NUMBER 0 Seg 2 HOUSE CODE X 10 ADDRESS CODES 0 see chart 1 B S F 9 J 13 N Seg3 SINGLE SCAN FUNCTION 1Beep 2 0 All units off 1 All lights on 2 On 3 Off 4 Dim 5 Bright 6 All lights off NX 1701E Installation manual Page 16 31 01 05 Networ 7 LOC PG DESCRIPTION DEFAULT YOUR DATA 241 10 Seg4 DOUBLE SCAN FUNCTION 2 Beep 3 0 All units off 1 All lights on 2 On 3 Off 4 Dim 5 Bright 6 Alllights off Seg5 SINGLE
25. he X 10 function that is performed when a card is scanned one beep This location only needs to be Function Function performed Function Function performed 0 All units off 4 Dim 1 All lights on 5 Bright 2 On 6 All lights off 3 Off All others Reserved Segment 4 Double Scan Function Double Beep Program the X 10 function that is performed when a card is scanned twice within the 2 Scan Hold Time two beeps Location 244 Segment 1 programs the length of time between beeps The descriptions of the function codes are the same as for Single Beep Scan Function This location only needs to be programmed if Location 0 Segment 2 Option 7 is set Use the above table Default is 3 Segment 5 Single Scan Hold Function Triple Beep Program the X 10 function that is performed when a card is scanned and held at the reader for the duration of the 2 Scan Hold Time three beeps Location 244 Segment 1 programs the length of time between beeps The descriptions of the function codes are the same as for Single Beep Scan Function This location only needs to be programmed if Location 0 Segment 3 Option 7 is set Use the above table Default is 2 Location 242 Programming the Options and Reader Partition 4 segments of binary data Segment 1 System Options LED1 On if reader is enabled for User Card Programming LED2 On if optical tamper is enabled LED3 On if reader buzzer is to follow typical ke
26. iate addressing FOB within one short beep When completed 1 2 seconds the reader will beep back its address long beeps Refer to Table 0 1 that follows for possible addresses Table 0 1 114 11s sensing range of the card reader module Address PROGRAMMING USING THE LED KEYPAD Only NX 13xx keypad series allow to program user cards ACTION RESULT Entering the Program Mode FROE 000TH SE Factory Default is 7 1 Entering the Module Address Scan a card re FOGOH cree example only NX 1701E Installation manual Page 5 Go To Program Code eS Enters the Program Mode Stay Chime Exit Bypass amp Cancel LEDS will flash If the Go To Program Code is valid the Service LED will flash and the 5 function LEDs will illuminate steady You are now in the Program Mode and ready to select the module address The card reader will address itself Enters the module address Refer to Table 0 1 on page 5 for the address assigned by the card reader module itself The Armed LED will illuminate while it is waiting for a programming location to be entered 31 01 05 Networ Programming a Location JS Ifan attempt is made to program an invalid entry for a particular segment the keypad sounder will emit a triple error beep beep beep beep and remain in that segment awaiting a valid entry To Enter a Location CP location HF ERR The Armed LED will flas
27. igit user code o O if 6 digit user codes Scan any card De Activate One User ACTION Bypass 7 3 digit user number Example if 4 digit user code or O if 6 digit user codes Scan any card Delete Reset One User ACTION gt exit 7 3 digit user number Example if 4 digit user code or O if 6 digit user codes Scan any card Accesses Activation mode If a valid user number is entered LED1 on any enabled readers will begin to flash The card information for the user entered in the previous step will be activated and LED1 will stop flashing After about 30 seconds all the readers in the system will be updated RESULT Accesses De activation mode If a valid user number is entered LED1 on any enabled readers will begin to flash The card information for the user entered in the previous step will be cleared and LED1 will stop flashing After about 30 seconds all the readers in the system will be updated NSS If an individual keeps the card it can still be deleted RESULT Accesses De activation mode If a valid user number is entered LED1 on any enabled readers will begin to flash The card information for the user entered in the previous step will be cleared and LED1 will stop flashing After about 30 seconds all the readers in the system will be updated JS ACTIVATING DE ACTIVATING RESETTING USERS If User Number 0
28. ment 1 must be faulted before sending an alarm condition to the control panel The door fault alarm is timed in 1 second increments from 0 to 255 seconds Default is 0 0 seconds Location 245 Resetting the Reader Address 1 segment of numerical data If it is necessary to reset the address of the reader enter a 0 in this location This will cause the reader to cease functioning If a card is scanned with the system in Program Mode the reader will again find an available address and set itself beeping back to the user the address that was found as per the table on page 5 If the system is not in Program Mode and a card is scanned at a reader with a reset address then it will sound an error beep Location 246 Programming the Access Options 2 segments of binary data Segment 1 Door Options LED1 On if locking mechanism is a Maglock or Drop Bolt LED2 On if access is allowed regardless of Armed status of the system LEDS On if the door is not to be latched unlocked during an open schedule LED4 On if onboard open collector output only triggers during an open schedule LED5 On if onboard open collector output only triggers during a close schedule LED6 On if Forced Entry Alarm is logged LED7 On if access allowed without an RTE LED8 On if relay operates normally during off schedule outside of regular operating hours Segment 2 Enabling the Schedules for the Onboard Open Collector Output
29. ment 15 User Cards 233 240 EDS ade Segment 8 User Cards 177 184 Location 285 Code Entry Logging Partition 1 segment of numerical data This location programs the partition that is logged with the Code Entry message and sent when the following conditions are met gt An RTE scan function is selected Location 0 Segment 1 2 3 Option 8 and gt RTE from a scanned card is to be logged as Code Entry is enabled Location 242 Segment 1 Option 5 Entering a 0 zero will send the lowest valid partition of the reader Entering 1 16 will send the entered value as the partition Default is 0 NX 1701E Installation manual Page 15 31 01 05 Rietwo 9 PROGRAMMING WORKSHEETS Kole PG DESCRIPTION DEFAULT YOUR DATA 0 10 SCAN FUNCTIONS Seg1 SINGLE SCAN FUNCTION 1 Beep 8 1 On to send Code Entry function to the control panel 2 On to activate the Armed Away mode 3 On to activate the Armed Stay mode 4 On to send the Disarm function to the control panel 5 On to send Auxiliary Function 1 to the control panel 6 On to send Auxiliary Function 2 to the control panel 7 On to broadcast an X 10 function Loc 241 for programming 8 On to send an RTE and activate the onboard open collector output Seg 2 DOUBLE SCAN FUNCTION 2 Beep 1 1 On to send Code Entry function to the control panel On to activate t
30. n if egress input is to be disabled 2 Reserved 3 Reserved 4 Reserved 5 Reserved 6 Reserved 7 Reserved 8 Reserved 247 14 OPENING TIME FOR SCHEDULE 1 Seg1 Hour of Opening Time 24 hr format 8 8AM Seg2 Minutes after Hour of Opening 0 248 14 CLOSING TIME FOR SCHEDULE 1 Seg1 Hour of Closing Time 24 hr format 20 8 PM Seg2 Minutes after Hour of Closing 0 NX 1701E Installation manual Page 18 31 01 05 RNietwo 9 LOC PG DESCRIPTION DEFAULT YOUR DATA 249 14 DAYS FOR SCHEDULE 1 1 On if schedule is active on Sunday 2 On if schedule is active on Monday 3 On if schedule is active on Tuesday 4 On if schedule is active on Wednesday 5 On if schedule is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is active on Saturday 8 On if schedule is disabled on holidays 250 14 OPENING TIME FOR SCHEDULE 2 Seg1 Hour of Opening Time 24 hr format 8 8AM Seg2 Minutes after Hour of Opening 0 251 14 CLOSING TIME FOR SCHEDULE 2 Seg1 Hour of Closing Time 24 hr format 20 8 PM Seg2 Minutes after Hour of Closing 0 252 14 DAYS FOR SCHEDULE 2 1 On if schedule is active on Sunday 2 On if schedule is active on Monday 3 On if schedule is active on Tuesday 4 On if schedule is active on Wednesday 5
31. nt procedure instruction condition or statement Indicates a user tip Provides helpful information that is not normally defined in regular use but from an experienced user Indicates a key or button should be pressed to enter data Page 2 31 01 05 Networ g TABLE OF CONTENTS TABLE OF CONTENTS wa f2s nsiediid dele Ghat ee dle ANT ee ny Bk ete e Abe ed de heated as 3 GENERAL DESCRIPTION iriiri itt i te enes fee bes den ahead ese ad titer a a a 4 INSTALL ATIIONGAND WIRIIN Gns rart a karrene eae ii cae has aera cee a ys eke 4 ENROLLING Eritrea Bie Auta cotati ae NNER tN ON cette SEER etern Na a haan die 4 ADDRESSING re Sine atic locate eect a Gat nere enedes E A O aad dean 5 PROGRAMMING EEEE EEEE E E EASE SOD See RAE Sod a SED AN oe ET Sl BE cesta SAL Seen ak ERE ETE oe hts 5 USING THE LED KEYPAD Entering the Program Mode Entering the Module Address BYS Sten ist OME I Era a SNE TERE TRE Ea N E ERR ERE ES REE SEES E ON N g Delete Reset ONE USC snaedis ebdre dre o AE Rare e EISE EEEE AAEE ENEE 9 PROGRAMMING LOCATION Sora sssseacdereeccaivigen are niio ET EREE ATEEN NANREN EEO TE GORR 10 Location 0 Programme Te Scant Unc UIE aoreet e eE EE ENON 10 LOCATIONS 1 240 Reseed nisnin a r a a E A NEA Ei A E RA 10 Location 241 Programming the X 10 Address for the Scan FUNCtIONS sesssscssssssssssssssssssscsssssssssesssssscssssssssssssseseesssssssssessseeees 10 Location 242 Programming the Options and Reader Partition ue LOGQU
32. s sensor remove it from the field then pass the card by the reader s sensor once again during the time programmed in Location 244 Segment 1 This is a double scan in the legacy mode Request To Exit RTE Azone can be programmed to monitor an open door The RTE activates the onboard open collector output and sends a message on the buss Seah To present or pass a card or FOB within sensing range of the card reader module Single Beep An audible indicator beep Single Beep Scan When a user card is scanned and held at the reader for 1 beep the reader will perform the functions as programmed in Location 241 Segment 3 Triple Beep An audible indicator beep beep beep Triple Beep Scan When a user card is scanned and held at the reader for 3 beeps the reader will perform the functions as programmed in Location 241 Segment 5 NX 1701E Installation manual Page 23 31 01 05 Networ 7 SPECIFICATIONS DIMENSIONS Approx 38mm W x 114mm L x 25mm D with 150mm cable OPERATING POWER 12 VDC Supplied by panel or NX 320E CURRENT DRAW 40mA Standby with Green LED 110mA Maximum OPERATING TEMPERATURE 31 to 151 degrees F 35 to 66 degrees C NX 1701E Installation manual Page 24 31 01 05 RY Networ G DECLARATION OF CONFORMITY Product identification Model type Category description Brand Manufacturer EU Representative GE Interlogix SECURITY LIFESAFETY COMMUNICATION
33. se this feature connect the coil contacts of a relay between this terminal and BLUE AUX POWER Absolute maximum 14 volts 25mA OUTPUT This is a low current output and must not be used to directly energize high current door openers ENROLLING The Networx control panels have the ability to automatically find and store in memory the presence of all keypads zone expanders wireless receivers output modules and any other device on the keypad buss This allows these devices to be supervised by the control panel To enroll the devices enter the Program Mode using the procedure outlined in the control panel Installation Manual When the Program Mode is exited the NX 8 control will automatically enroll the devices The enrolling process takes about 12 seconds during which time the Service LED will illuminate User codes will not be accepted during the enrolling process Once a module is enrolled if it is not detected by the control the Service LED will illuminate NX 1701E Installation manual Page 4 31 01 05 Networ i ADDRESSING Once the reader is wired into the system the module needs to be addressed Unlike most Scan To Networx expanders the address of any particular reader is determined by itself after installation present or is complete Follow the procedures outlined under the section PROGRAMMING When prompted pass a card or to enter the module device number a card must be scanned at the reader to init
34. the reader will triple beep and LED1 will continue flashing the user number is not incremented in this case ACTION RESULT CP CAN CEL on NX 148E use NIGHT on NX 1248E 3 digit user number Example if 4 digit user code or O if 6 digit user codes Scan the card designated for the user tt tte entered in the previous step Continue scanning user cards until the desired number of cards has been added Accesses Activation mode If a valid user number is entered LED1 on any enabled readers will begin to flash 1 If the user card is not already in the system it will be added and mapped to the entered user number and LED1 will continue flashing indicating that the next user card can be scanned for the next user number 2 Ifthe card is already in the system the reader will triple beep and LED1 will continue flashing the user number is not incremented in this case After about 30 seconds without a card being scanned all the readers in the system will be updated with the new user card information By default user cards are added and activated In order to add a user card and de activate it at the same time scan and hold the card to be added until two beeps are sounded at the reader NX 1701E Installation manual Page 8 31 01 05 Networ MS Activate One User Single User ACTION RESULT CP CH M E not available on NX 1248E 7 3 digit user number Example if 4 d
35. ypad buzzing Default is On LED4 On if ding dong chime enabled dependent on both Option 3 and chime being enabled LED5 On if an RTE from a scanned card is to be logged as Code Entry Default is On LED6 On if reader is in NX 1701E Legacy Mode Default is On Refer to note below LED7 On if an RTE from a zone or the Egress input is to be logged as Code Entry LED8 On if LEDs to extinguish after 2 minutes without a scan Note This option doesn t disable the flashing green LED during card programming BS The card reader is defaulted to the Legacy mode This mode uses the same scan method as previous NX 1701E card readers However an alternative scan method is available by turning off LED6 in Location 242 Segment 1 Rather than passing the card scan within range of the card reader the card can be held at the reader for a specified number of beeps Example of Double Scan Legacy mode Pass the card by the reader s sensor remove it from the sensor area then pass the card by the reader s sensor once again Alternative mode Hold the card at the card reader for a total of 2 beeps Refer also to the Glossary on page 23 IMPORTANT If you have older models installed in the system without this enhanced feature it could result in two different methods of scanning at various readers NX 1701E Installation manual 31 01 05 Networ Segment 2 LED1 Green Options LED1 On to follow Rea