1. 50 Chapter 1 WARNINGS AND SAFETY The stoves produced in our factory are built with maximum dedication to the individual components so as to protect both the user and the installer from accidents Authorised personnel are therefore advised to pay special attention to the electrical connections above all after any servicing operation onthe product especially with regard tothe stripped part of the wires which must not protrude in any way from the terminal block to prevent possible contact with the live parts of the wire Installation must be carried out by authorised personnel who have to provide a declaration of conformityoftheapplianceforthe purchaser who will then be fully responsible for the permanent installation and consequent correct operation of the installed product It is necessary to bear in mind all the national regional provincial and municipal laws and regulations present in the country in which the appliance is installed Extraflame S p A may not be held responsible in the event of failure to observe these precautions This instruction manual constitutes an integral part of the product It must always accompany the appliance also when it is transferred to another owner or user or moved to another location If the manual gets damaged or lost ask your local service centre for another copy This stove must only be used for the applications for which it was expressly designed The manufacture
2. 26 CARAT TERIS TICHE GENERBDBEE iacit dotes erus Hte eec euet it hut und faceres 27 at 27 P QNO 27 Chapter 8 29 29 X 29 NORMAL 30 SHUTDOWN 30 Chapter 9 USER MENUS Y 31 SET TEMPERATURE MENU T 32 SET CLOCK MENU 32 MENU M 32 34 PELLE FELOAD MENU 35 LANGUAGE MENU 36 Chapter 10 ROOM THERMOSTAT 37 MECHANICAL THERMOSTAT van ia qan ERU NER Ine EE HEINE SR 37 IN
3. 21 N B The tank support only be fitted the right hand side of the insert Adjust the height and angle of the tank according to the fireplace to be built The insert must stand atleast 1 cm above the marble fire top of the facing EXTRACTING THE INSERT Extraction ofthe insert allows to feed the pellets into the tank and to perform routine maintenance cleaning the ash chute every year or extraordinary maintenance replacement of mechanical parts if the product should break These operations must be carried out by an authorised technician with the stove switched off and the plug disconnected To extract the insert proceed as follows 1 Open the fire door and use the socket wrench provided to turn the screw in the lower left hand corner anticlockwise 2 Using the pokers provided pull the insert towards you until it blocks automatically FITTING THE FRAMES Front frame Side frames Attach the front frame to the two side frames Fix the frames to the insert using self tapping screws N B Any wooden beams situated above the insert must be protected using fireproofing material Frame assembly is important as it allows correct air circulation in the insert and consequently the most efficient stove operation The 2 side frames are fitted to the upper H frame using 2 screws per side The remaining holes on the side frames are used for att
4. Inserto Comfort Mini Inserto Comfort P80 User Manual Read these instructions carefully before installation use and maintenance The instruction booklet is an integral part of the product OExtraflame Congratulations You now the owner of an EXTRAFLAME stove The Extraflame pellet stove is an ideal heating solution It utilises the most advanced technology and is manufactured to the highest standards with a contemporary design allowing you to enjoy the ambience and warmth of a natural flame in complete safety This manual tells you how to use your stove correctly Please read the entire manual carefully before using your stove IMPORTANT Make sure that the dealer completes the following box with the details of the authorised specialist who will help you if you have any problems in using your new pellet stove AUTHORISED SPECIALIST COMPANY NAME ADDRESS POST CODE TOWN CITY TEL FAX All Extraflame products are manufactured according to the following directives 89 106 CEE Construction products 89 366 CEE Directive 2004 108 EMC Directive 2006 95 CE Low Voltage Directive And the following standards EN 14785 EN 60335 1 EN 60335 2 102 EN 55014 2 te OExtraflame OExtraflame Index Chapter 1 WARNINGS AND SAFET isisissssistivcutinetisstintinwiiivcninaiiiimalnwiiincninuiiiiiwainudiivuatie 7 Chapter 2 T
5. 27 24 COMFORT MINI P80 INSTALLATION Chapter 6 OExtraflame Warm convection air It is necessary provide an outlet for the heat accumulated in the facing to prevent excessive overheating of the insert Forced ventilation The blower conveys the heat produced in the insert into the room Air inlet from the room To enable air circulation it is necessary to have an air inlet point preferably at d the lower part of the structure for better uc CELL 177777 convection The air must be drawn from the room where the stove is installed figure 28 To ensure the correct and safe operation of the insert when building the fireplace it is necessary to respect the clearances between the insert and the inner walls of the fireplace Considering the measurements given in the technical specifications you need to account for at least 50 mm of air space in the upper part and on the two sides NB The exhaust outlet pipe must always be at a minimum distance of 5 cm from flammable parts 25 COMFORT MINI P80 INSTALLATION REMOTE CONTROL OPERATION GENERAL DESCRIPTION The radio frequency remote control has two way communication with the electronic board sending commands and displaying the operating status of the stove N B Certain radio frequency devices e g mobile or cordless phones etc can interrupt the communication between the remote co
6. 1 button again gt the display will show CLOCK SET MENU 3 Press button 5 twice the display will show DAY NIGHT MENU 4 Confirm with the menu 2 button When you have entered the programming function the display will show the following parameters Parameter ut gt DAY NIGHT Use buttons 4 and 5 to enabling disenabling the day night temperature function To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button 34 USER MENUS Parameter ut b DAY START Use buttons 4 and 5 to set the day start night end To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter ut gt DAY END Use buttons 4 and 5 to set the day end night start To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter ut d gt MAX DAY TEMPERATURE Use buttons 4 and 5 to set maximum temperature for the day period To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter ut E MAX NIGHT TEMPERATURE Use buttons 4 and 5 to set maximum temperature for the night period To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button When the stove switches off because the m
7. have technical advantages While the heating power of wood is 4 4 kW kg with 1596 humidity after about 18 months seasoning the power of pellets is 5 3 kW kg The density of the pellet is 650kg m3 and the water content is 896 of its weight For this reason pellets do not need to be seasoned to obtain a sufficient heating yield The pellet used must conform to the characteristics of the following regulations Norm M 7135 DIN plus 51731 UNI CEN TS 14961 Extraflame recommends always using 6 mm pellets for its products PELLET STORAGE To guarantee problem free combustion the pellet must be stored in a dry place PELLET LOADING Pellets can either be loaded from the front by removing the insert or from the side by using the chute if equipped with the support and loading kit warnine THE USE OF POOR QUALITY PELLETS OR ANY OTHER MATERIAL MAY DAMAGE THE YOUR STOVE AND MAY LEAD TO THE INVALIDATION OF THE WARRANTY AND THE RELATED RESPONSIBILITIES OF THE MANUFACTURER WHAT ARE PELLETS 11 SAFETY DEVICES BREAKDOWN OF HOT AIR DISTRIBUTION FAN If the blower stops for any reason the stove automatically shuts down to prevent overheating FLUE GAS EXTRACTOR BREAKDOWN If the extractor stops the electronic unit immediately prevents pellet loading PELLET LOAD MOTOR BREAKDOWN If the motor stops the stove continues to operate until the minimum cooling level is reached FAILED IGNITION If no flame develops during the
8. ignition phase the appliance automatically attempts a new ignition this time though without loading pellets If after this attempt the stove still has no flame the stove display shows NO FLAME If you attempt to light the stove again the display shows CLEANING WAIT which means WAIT This function reminds you that before lighting the stove you must be sure that the brazier is free of dirt and debris TEMPORARY POWER CUT The appliance will re light automatically after a brief power failure When the power goes off the stove may emit a minute quantity of smoke inside the house for a period of 3 to 5 minutes THIS DOES NOT POSE ANY SAFETY RISK ELECTRICAL SAFETY DEVICE The stove is protected against violent changes in power by a master fuse on the rear of the stove 2A 250V delayed FLUE GAS EXHAUST SAFETY DEVICE If the exhaust system fails an electronic pressure switch stops the stove and an alarm is signalled PELLET TEMPERATURE SAFETY DEVICE In case of overheating inside the pellet tank this safety device blocks stove operation resetting is manual and must be performed by an authorised technician 12 SAFETY DEVICES Chapters QExtraflame ASSEMBLY AND INSTALLATION INSTRUCTIONS The installation must comply with UNI 10683 2005 heat generators fed with wood and other solid fuels installation The chimneys must comply with UNI 9731 1990 chimneys classification according to thermal resistanc
9. installation use and maintenance manual by qualified personnel 2 The warranty certificate has been filled in and signed by the customer and convalidated by an Extraflame S p A Technical Assistance Centre or by the vendor 3 The document which proves the warranty filled in and accompanied by the receipt is duly conserved and shown to Extraflame S p A personnel in the event of an intervention The warranty is not considered valid in the following cases 1 Warranty conditions have not been respected 2 Installation has not been carried out respecting all related norms or the information in this manual 3 Whenever the client is judged to have been negligent due to incorrect or absent maintenance of the stove 4 Presence of electrical and hydraulic systems not compliant with the current norms 5 Damage caused by atmospheric chemical or electrochemical agents improper use of the product modifications or tampering with the product unsuitability of the flue chimney and or any other causes not depending on the manufacture of the product 6 Damage caused by normal corrosion phenomena or deposits typical of heating systems condition valid for products using water 7 Damage caused by the use of non original spare parts or due to service performed by technical personnel not authorised by Extraflame S p A 8 Improper or negligent use of the stove 9 Any damage caused by transport We therefore recommend that you carefully inspect
10. nii iconem 15 CHIMNEY OR SINGEE Lisci etate 16 CONNECTION TO THE FLUE AND COMBUSTION PRODUCT EXHAUST VENTING 18 MW ings c 18 CONNEC TION TO EXTERNAL aaia 19 INSULATION TRIMS FACINGS AND SAFETY 5 19 NATIONAL REGIONAL PROVINCIAL AND MUNICIPAL LAWS 19 Chapter 6 COMFORT MINI PSO INSTALLATION ap Eo uin qvo YU n qun o Servo eoo peas ey peus Sess 20 BA bo drerit omg feno nis euni nds 20 INSTALLATION WITH PEDESTAL OPTIONAL rti queis eeu Pasce aac e S 21 INSTAEEATION WITH PEDES niii 21 EXTRACTING THE cb cU 22 FEIING TREFRAME X TE 22 AIR CIBCUEATIOIN DUCTS incipe Cat 23 Chapter 7 REMOTE CONTROL 26 GENERALE DESCRIPTION S eia etse aei ictu state Ren ies
11. the goods on receipt immediately notifying the vendor of any damage and making note of such on the shipping document and on the shipper s copy 48 WARRANTY Extraflame S p A is not liable eventual damage which may be caused either directly or indirectly to people things and pets as the result of not following the instructions indicated in this installation use and maintenance manual or the current norms related to installation and maintenance of this product The warranty excludes The gaskets all ceramic or tempered glass cast iron or lronker facings or grills painted chromium plated or gold plated components majolica handles and electrical cables Chromatic variations cracks and slight variation in size of the majolica pieces do not constitute a reason for contestation as they are natural characteristics of the materials themselves Building works Parts for the production of domestic hot water not supplied by Extraflame S p A only products using water The heat exchanger is excluded the warranty unless an anti condensation circuit is installed only products using water The warranty excludes any calibrations or adjustments of the product relating to the type of fuel or type of installation Other clauses Should any faulty or malfunctioning part be detected during normal use these parts will be replaced free of charge by the vendor or b
12. 1 1 111 1 11111 1 tt tt Serial number EE Vendor Date of purchase IMPORTANT accept do not accept Notice as per Law 196 2003 Your personal data is treated by our company with full respect for Italian Law 196 2003 for the entire duration of the contractual relationships established and also thereafter for the fulfilment of all legal obligations as well as to carry out effective management ofthe commercial relationships The data may be communicated to other external subjects only for the purpose of overseeing credit matters and for the protection of our rights regarding the single commercial relationship and may also be communicated to third parties for the fulfilment of specific legal obligations The interested party has the right to exercise his rights as per Art 7 of the above said law 50 QUALITY CONTROL QExtraflame Notes Stufe a Pellet EXTRAFLAME S p A Via Dell Artigianato 10 36030 MONTECCHIO PRECALCINO Vicenza ITALY Tel 0445 865911 Fax 0445 865912 www lanordica extraflame com E mail info extraflame com This document is at your disposal at www extraflame it support 004275115 REV 008 16 05 2008 Manuale utente Comfort Mini Comfort P80
13. ECHNICAL SPECIFICATIONS 54 445444 844544 444 444 844 QE GIG ME NE 8 Chapter 3 WHAT 11 PELLET STORA GE TRI PNE 11 11 Chapter 4 SAFETY DEVICES 12 BREAKDOWN OF AIR DISTRIBUTION 12 FLUE GAS EXTRACTOR BREAKDOWN 12 PELLET LOAD MOTOR BREAKDOWN 12 FAILED IGNIMION c C H 12 TEMPORARY POWER EV T C aD S EIE M 12 ELECTBICAE SAFETY DEVICE Ert Att Er 12 FEUE GAS EAHAUSESAFELY DEVICE ante aere 12 PELLET TEMPERATURE SAFETY DEVICE xir faces 12 Chapter 5 ASSEMBLY AND INSTALLATION INSTRUCTIONNSS eene eee ee eee eese eese eese sees esee eese e eese sees e esee seen 13 1 9 Histo cu nube Uns 13 INSSTALEATRODU diiit tinta tube net atu ii hito ted 14 ADMISSIBLE INSTALLATION S feti beni ette etae bete dean 14 PROHIBITED INSTALLATION 14 CONNECTION TO THE FLUE GAS VENTING SYSTEM 15 EXHAUST TPIPEORTII
14. ECTION TO EXTERNAL AIR INLETS To ensure correct operation the appliance must have sufficient air available by means of external air inlets which must meet the following requirements 1 They must have total free section of at least 80 2 They must be protected by a grate metal mesh or other suitable protection provided that it does not reduce the minimum section as per point a and that it is positioned in such a way as to prevent the intakes from being obstructed If the combustion air is collected directly from the outside by means of a pipe it is necessary to fit a downward bend or a wind hood on the outside In addition no grating or similar device should be positioned Extraflame S p A suggests creating an air inlet directly communicating with the installation room even if air is collected from outside by means of a pipe Air inflow can also be obtained from room adjacent to the installation room provided that flow can occur freely through permanent openings communicating with the outside The adjacent room must not be subject to depression with respect to the outside as a result of the opposing draught caused by the presence of another utility device or suction device in this room In the adjacent room the permanent openings must meet the requirements described above The adjacent room cannot be used as a garage storage area for combustible material or for activities involving fire hazards INSULATION TRIMS FACING
15. MABLE LIQUIDS FOR LIGHTING 2 WHEN FILLING DO NOT BRING THE SACK OF PELLETS INTO CONTACT WITH THE HOT STOVE N B In case of continued ignition failures contact an authorised technician PRODUCT FUNCTIONALITY 29 NORMAL OPERATION When the stove has been lit the user can adjust the heating power using buttons 4 and 5 By pressing 4 the heating power and the pellet consumption will decrease while by pressing 5 it will increase In addition to the feed rate the room temperature can be set directly from the control panel The stove adjusts itself automatically as far as warm air ventilation is concerned The contents of the tank should be monitored to prevent the stove going out because of a lack of fuel attention The cover of the pellet container must be kept closed except when loading fuel The sacks of pellets must be kept at least 1 5 metres away from the stove The pellet tank should always be kept half full The appliance should be switched off before filling with pellets SHUTDOWN Press button 1 for three seconds When the three seconds have elapsed the stove automatically starts the shutdown stage cutting off the pellet load the display will Show FINAL CLEANING Both the exhaust motor and warm air ventilation motor continue to run until the stove temperature has dropped sufficiently When the exhaust motor stops the display will show OFF 30 PRODUCT FUNCTIONALITY USER MENUS The table b
16. S AND SAFETY PRECAUTIONS The facings no matter what type of material they are made of must constitute a self bearing structure with reference to the heating assembly and not in contact with it The beam and the trims in wood or combustible materials must be positioned outside of the radiant area of the hearth or be properly insulated If the space above the heat generator has coverings made of combustible or heat sensitive material a protective membrane made of non combustible insulating material must be placed between it and the generator All elements made of combustible or flammable material such as wooden furnishings curtains etc which are directly exposed to the radiance of the hearth must be placed at a safe distance The installation of the appliance must guarantee easy access for cleaning the appliance itself of the exhaust gas pipes and the flue NATIONAL REGIONAL PROVINCIAL AND MUNICIPAL LAWS All the national regional provincial ad municipal laws of the country where the appliance has been installed must be taken into consideration ASSEMBLY AND INSTALLATION INSTRUCTIONS 19 COMFORT 80 INSTALLATION The insert is supplied with a sliding base in iron which allows it to be installed in a pre existing chimney The base allows you to slide out the insert easily for maintenance and cleaning at the end of the year If you do not already have a fireplace you can build one using the in
17. STALLING A MECHANICAL THERMOSTAT 37 MECHANICAL THERMOSTAT OP ERATION 37 MECHANICAL THERMOSTAT OPERATION IN STANDBY MODE BE USED ALSO FOR REMOTE ACTUATOR nese 37 Chapter 11 M 38 CLEANING THE BRAZIER c 38 SCRAPERS 38 CLEANING ASH COLLECTION COMPARTMENTS 38 CLEANING THE HEAT EXCHANGER MON THEY 38 DOOR ASH DRAWER AND BRAZIER tend eo tores testo 39 Mee cc 39 PH 40 Chapter 12 WIRING DIAGRAMS R HR A 41 COMFORT MIN p X 41 COMFORT PSO cc 43 Chapter 13 TABLE OF DISPLAY 55 5 ag nd ak ag ek da eden ag en Gd aa EF ar aaa 45 Chapter 14 WARRANTY 48 Chapter 15
18. aching the entire frame assembly to the sides of the insert using self tapping screws SECTION F F figure 21 22 Chapter 6 figure 19 figure 20 COMFORT MINI P80 INSTALLATION QExtraflame AIR CIRCULATION DUCTS For correct function air circulation must be created inside the structure that covers the insert in order to prevent the appliance overheating The following measurements must be respected 4 Lower part cold air inlet total minimum surface 550 Upper part hot air outlet gt total minimum surface 500 N This ventilation system is completely independent from the combustion air inlet To protect against overheating the comfort P80 is supplied with a probe that analyses the temperature inside the structure and intervenes by reducing the functioning power Comfort Mini Comfort P80 ___ figure 22 figure 23 COMFORT MINI P80 INSTALLATION 23 Comfort Mini Comfort P80 sez H H figure 26 figure 27 It is also important to guarantee the minimum distance of 5 cm on both sides as illustrated in figures 26
19. any modifications in order to improve the performance of the product 8 TECHNICAL SPECIFICATIONS Inserto Comfort Mini 2824 b 2523 2 3 398 w 1 558 Roo 1 _ 3 232 5 e 313 550 923 449 3 901 qo CVE 282 028 figure 1 TECHNICAL SPECIFICATIONS 9 Inserto Comfort P80 2223 8 2973 D 5 3 amp lt 5 2 5 5 Bm 8 2 z 2 2 YOO m uS S au 598503 oe gt 22 amp Om 582 figure 2 10 TECHNICAL SPECIFICATIONS WHAT PELLETS Pellets are made by applying very high pressure to sawdust i e the residue of raw timber without paint produced by sawmills carpentry works and other activities involved in processing wood This type of fuel is completely environmentally friendly as no binders of any kind are used to keep it compact In fact the compactness of the pellets over time is guaranteed by lignite a natural substance found in the wood itself As well as being an environmentally friendly fuel since wood residues are exploited to the maximum pellets also
20. as to prevent the penetration of rain snow and foreign bodies into the chimney as well as to assure the discharge of the combustion products also in the presence of winds coming from any direction and at any angle be positioned in such a way as to assure proper dispersion and dilution of the combustion products and in any case outside the reflux area in which the formation of counter pressure is most likely to occur This area has different sizes and shapes depending on the slope of the roof therefore it is necessary to use the minimum heights indicated in the figures below The chimney cap must not have any mechanical suction devices FLAT ROOF 50 cm 50 gt 5 lt 5 lt 5 Dx figure 11 LOPED ROOF SLOPED ROOF Distance A Distance A 50 cm beyond the ridge beam REFLUX AREA Reflux area height figure 12 18 ASSEMBLY AND INSTALLATION INSTRUCTIONS chapters Extraflame CHIMNEYS DISTANCES AND POSITIONING Roof pitch Minimum height of the chimney crown and the chimne measured from the outlet 1 85 0 50 m beyond the crown gt 1 85 1 00 m from the roof 1 50 0 50 m beyond the crown gt 1 50 1 30 m from the roof lt 1 30 0 50 m beyond the crown gt 1 30 2 00 m the roof 1 20 0 50 m beyond the crown 2 60 m from the roof CONN
21. ast iron levers 38 Chapter 11 figure 37 figure 38 CLEANING cw Once the heat exchanger chamber is accessible use the ash hook to remove the deposited residues and scrape off any encrustation Finally use a vacuum cleaner to complete the cleaning figure 42 After that proceed in reverse order to reposition the pull out cast iron Once the furnace wall is in position rotate the door latch by 180 to return it to its original position figure 41 figure 42 DOOR ASH DRAWER BRAZIER SEALS The seals ensure that the stove is hermetically sealed and consequently that it operates correctly The seals should be checked periodically and replaced immediately if worn or damaged These operations must be carried out by an authorised technician N B To ensure correct operation the stove should have general maintenance performed at least once a year by an authorised technician If the power cable is damaged it must only be replaced by the service centre or by a qualified technician in order to avoid any risks CHIMNEY CONNECTION Once a year or whenever needed vacuum and clean the duct that leads to the chimney If there are horizontal sections remove any ash residues before they can obstruct passage of the smoke FAILURE TO CLEAN jeopardises safety CLEANING 39 BRAZIER PARTITION The insert is supplied with a divider fixed to the brazier by a screw which allows to optim
22. aximum temperature has been reached the display shows doff The stove will switch on again automatically when the room temperature is 3 C lower than the maximum temperature set Ex Stove status gt doff Max temperature set gt 25 When the room temperature goes below 22 C 25 3 22 C the stove will automatically start again N B This only occurs when the stove is in doff status and not OFF status controls always have priority over the programming PELLET LOAD MENU If the stove has operating problems due to the quantity of pellets you can adjust the pellet load directly from the remote control Problems related to the quantity of pellets fall into one of two categories 1 LACK OF PELLETS b Atthe lowest speed the stove tends to almost burn out causing the stove to go into NO PELLET alarm status When NO PELLET is displayed there may still be some unburned pellets in the brazier USER MENUS 35 2 EXCESS PELLETS a The stove develops a very high flame even at low speeds b The flame tends to soil the stove window darkening it almost completely c The brazier tends to get incrusted blocking the air inlet holes due to the excessive pellet load that is only partially burned If this problem occurs just a few months after installation check to make sure that the user is correctly carrying out the regular cleaning schedule described in the instruction manual T
23. e EN 13384 1 2006 calculation method of the thermal and fluid dynamic features of the chimney UNI 7129 point 4 3 3 provisions local rules and prescriptions of the fire brigade UNI 1443 2005 chimneys general requirements UNI 1457 2004 chimneys internal ducts in terracotta and ceramics GLOSSARY CLOSED HEARTH DEVICE Heat generator that can only be opened to load fuel during use BIOMASS Material of organic origin excluding the material incorporated in geological formations and fossilised BIOFUEL Fuel produced directly or indirectly from biomass FLUE or CHIMNEY Vertical pipe for collecting and expelling combustion products from a single appliance at a suitable height from the floor EXHAUST PIPE or FITTING Pipe or connecting element between the heat generating device and the chimney for extracting the combustion products INSULATION The series of measures taken and materials used to prevent heat transmission through a wall dividing rooms at different temperatures CHIMNEY CAP Device located at the top of the chimney that facilitates dispersion of the combustion products in the atmosphere CONDENSATE Liquid products that form when the temperature of the combustion gas is lower than or equal to the dew point of the water HEAT GENERATOR Device that permits the production of thermal energy heat by the rapid transformation of the chemical energy of the fuel by means of combustion AIR LOCK Mechanism
24. e airtight for the operating conditions of the appliance as well as to limit the formation of condensates and prevent them from being conveyed towards the appliance The assembly of horizontal sections must be avoided where possible Where roof or wall exhaust outlets have to be reached that are not coaxial in relation to the exhaust outlet from the appliance the direction changes must be made using open elbows no greater than 45 see figures below Inspection N N NS L L V AV 2 2 ZZZ D 3 figure 4 For heat generating devices equipped with an electric exhaust fan i e all products made Extraflame it is necessary to observe the following instructions Horizontal sections must have a minimum slope of 396 upwards The length of the horizontal section must be as short as possible and in any case no greater than 3 metres No more than four direction changes may be used including the one resulting from the use ofthe T element When four bends are used use double wall piping with a 100 mm diameter e Oo any case exhaust pipes must be sealed in relation to combustion products condensates well as insulated if they pass outside the installation room It is forbidden to use elements in counter slope The exhaust channel must allow soot recovery and cleaning using a swab The exhaus
25. ed out this operation In this mode the stove no longer has a temperature level but works in manual mode with 5 powers To exit this mode press button 2 to lower the room temperature In this mode the stove only works exclusively at the 1st power level independently from the set power To exit this Mode press button 3 to increase the temperature To exclude an external thermostat simply disconnect it Other resetting operations must be carried out by an authorised technician In this mode the stove can be switched on off by using an external thermostat see Mechanical thermostat with energy saving To exclude this function increase the temperature by pressing button 3 To stop the stove from starting once more because of the Day Night Temperature Function press button 1 for three seconds turning the stove OFF To disable this function completely hold down button 4 and press button 5 at the same time Check the power supply of the stove Carry out the procedure Selecting the operating frequency described in the manual Remote control energy saving press button 4 or 5 to restore correct operation N B Certain radio frequency devices e g mobile and cordless phones etc may interrupt the communication between the remote control and the stove Other resetting operations must be carried out by an authorised technician room 45 ALARMS This indicator lights up when one of the alarms desc
26. ekly programmer see SET CLOCK menu ROOM TEMPERATURE Shows the current room temperature HEATING POWER Indicates the operating power It is set by the user during stove operation STOVE STATUS Shows whether the stove is off or on REMOTE CONTROL OPERATION 27 FAL HEATING POWER WORKING STOVE STATUS 28 REMOTE CONTROL OPERATION PRODUCT FUNCTIONALITY BASIC INSTRUCTIONS The stove you have purchased uses pellets as fuel This type of material is produced from natural waste from woodworking By means of a special process which does not require the use of any binders or additives the shavings are compressed in industrial machines under high pressure and become solid wooden pellets IT IS STRICTLY FORBIDDEN to burn any other material besides pellets in our stove Failure to respect these instructions will void all warranties and may jeopardise the safety of the appliance The first two or three times the stove is lit the following recommendations should be observed No children should be present as the vapours emitted can be harmful for health Adults too should not stay in the vicinity for very long Do not touch the surfaces as they could still be unstable Air the room thoroughly several times 9 The hardening of the surfaces is completed after several heating processes This stove must not be used as a waste incinerator IGNITION 1 Before proceeding check to make s
27. elow shows the various menus available to the user Menu Desmiptin 0 0 Menu for setting the temperature 2 Setclock Menu for setting the current day and time 3 Settimr Menu for setting the switch on off programmes Day Night Menu for day night temperature function Pellet load Menu for adjusting the pellet load 96 6 Set Language Menu for selecting the language The diagram below shows how the various user menus are accessed MAIN SCREEN menu 1 SET TEMPERATURE menu 2 SET CLOCK See Temperature Set Menu See Clock Set Menu See Timer Set Menu See Day Night Menu PELLET FEED See Pellet Adjustment Menu button 5 SET LANGUAGE menu gt see Language Menu USER MENUS 31 SET TEMPERATURE MENU The temperature value can be changed at any time by the user Press the menu 1 button the display shows ROOM TEMP SET Then use buttons 4 and 5 to select the desired temperature value the buttons enable the increase decrease of the room thermostat value from a minimum of 07 the display shows MIN to a maximum of 40 C the display shows MAX This value is shown on the first line of the display the third and fourth lines show ROOM TEMP SET When you have set the desired value confirm with button 1 SET CLOCK MENU This procedure is used for activating deactivating the weekly programmer and setting the current time The procedure can be carried out with the
28. ermostat in the various modes the day night temperature function is disabled in automatic mode ROOM THERMOSTAT 37 QExtraflame CLEANING CLEANING THE BRAZIER The brazier must be cleaned daily Remove the brazier from its container and clean the holes using the supplied relevant tool see figure 36 Remove the ash from the brazier using a vacuum Cleaner Suck up the ash deposited in the brazier compartment USE OF SCRAPERS Cleaning the heat exchangers guarantees a constant heat yield over time This type of maintenance must be carried out at least once a day To do this just use the appropriate scrapers positioned in the upper part of the stove performing the horizontal movement several times CLEANING OF ASH COLLECTION COMPARTMENTS The ash collection compartments indicated in figure 38 should be emptied as needed using a vacuum cleaner CLEANING THE HEAT EXCHANGER MONTHLY The heat exchanger chamber has to be cleaned once a month because the ash residue deposited on the back of the cast iron furnace wall obstructs the regular flue gas flow To be able to access the heat exchangers it is necessary to remove the central part of the furnace wall as described below Remove the brazier from its frame Rotate the door latch by 180 figure 40 Take the pull out cast iron and rotate it downwards lt Remove it from the combustion chamber pulling it towards you Pay attention to the two lateral c
29. for modifying the dynamic resistance of the combustion gases ASSEMBLY AND INSTALLATION INSTRUCTIONS 13 FLUE GAS VENTING SYSTEM A system for flue gas exhaust venting that is independent from the appliance composed of a pipe or channel chimney or single flue and chimney cap FORCED DRAUGHT Air circulation by means of a fan driven by an electric motor NATURAL DRAUGHT Draught resulting in a chimney flue due to the difference in the volume mass existing between the hot fumes and the surrounding atmospheric air without any mechanical suction aid installed inside or on top of it RADIANCE AREA Area immediately adjacent to the hearth in which the heat produced by combustion is diffused this area must not contain any objects made of combustible material REFLUX AREA Area in which the combustion products come out from the appliance towards the room in which it is installed INSTALLATION Before carrying out installation it is necessary to check the positioning of the chimneys flues or exhaust terminal ducts of the appliance bearing in mind the following Installation prohibitions Legal clearances Limitations set out by local administrative regulations or specific regulations of the authorities Common limitations deriving from building regulations and easement or contract regulations ADMISSIBLE INSTALLATIONS Intheroomin which the heat generatoristo beinstalled any existing orinstalled appliances must be airti
30. g operations must be carried out by an authorised technician authorised technician The pellet tanks empty Check the level in the pellet tank The spark plug is faulty or out of Check the procedures described in Ignition NO FLAME position Other resetting operations must be carried out Inadequate pellet load setting authorised technician NO FLAME Press button 1 to switch off the stove and repeat the procedure described in Ignition BLACKOUT Other resetting operations must be carried out authorised technician The pellet tank is empty Pellet feeding is insufficient The feed motor still has to settle in The geared motor is not loading pellets Check the level in the pellet tank Adjust the flow of pellets see Pellet Load Adjustment Other resetting operations must be carried out by an authorised technician Every time the stove visualises one of the above listed CLEANING WAIT alarms it will automatically switch off The stove will block any attempt to release the alarm during this phase visualising the alarm itself and COOLING WAIT alternately Release of the alarm using button 1 is only possible when the appliance is switched off When an alarm occurs the type of alarm detected and the telephone number of the service centre flash on the display in alternation If the number has not been entered the disp
31. ght to the room and must not cause depression in the room with respect to the external environment Appliances used for cooking foods and the related hoods without extractor can only be installed in rooms used as kitchens PROHIBITED INSTALLATIONS The room in which the heat generator is to be installed must not contain any of the following devices either pre existing or installed Hoods with or without extractor Ventilation ducts of the collective type Should these devices be located in adjacent rooms communicating with the installation room it is forbidden to use the heat generator simultaneously where there is the risk that one of the two rooms may be subject to depression with respect to the other 14 ASSEMBLY AND INSTALLATION INSTRUCTIONS CONNECTION TO THE FLUE GAS VENTING SYSTEM EXHAUST PIPE OR FITTING For the assembly of the exhaust pipes it is imperative to use non flammable materials that are resistant to combustion products and any condensates It is forbidden to use flexible metal pipes and asbestos cement for connecting the stove to the flue also for pre existing exhaust channels There must be continuity between the exhaust pipe and the flue so that the flue does not lean on the stove The exhaust pipes must not pass through rooms in which the installation of combustion devices is forbidden The assembly of the exhaust pipes must be carried out in such a way as to ensure that they ar
32. he adjustment is made on a percentage basis and therefore any change of this parameter leads to a proportional variation on all loading speeds of the stove To access the percentage adjustment of pellet loading proceed as follows 1 Press the menu 1 button gt the display will Show ROOM TEMP SET 2 Press the menu 1 button again gt sthe display will show CLOCK SET MENU 3 Press button 5 three times c the display will Show PELLET ADJUST MENU 4 Confirm with the menu 2 button When you have entered the programming function the display will show the following parameters Parameter ist PELLET LOAD Use buttons 4 and 5 to set the percentage increase decrease at 5 point intervals the parameter can be modified with a maximum scale from 50 to 50 When the adjustment has been made press menu 2 or 1 to confirm and exit Adjustment table Increase the percentage by 5 percent and try the stove with this new setting for at LACK OF least half an hour If the problem is reduced but not resolved increase by a further 5 PELLETS percent Repeat this process until the problem is resolved If the problem cannot be resolved contact the service centre Decrease the value by 5 percent and try the stove with this new setting for at least half an hour EXCESS If the problem is reduced but not resolved decrease by a further 5 percent Repeat this process PELLETS until the problem is resolved If the problem cannot be resolved contact the se
33. ht up N B Theinsert must stand atleast 1 cm above the marble fire top of the facing INSTALLATION WITH PEDESTAL OPTIONAL Description of components Comfort Mini P80 Pedestal adjustable in height Side feeding tank Adjustable tank support INSTALLATION WITH PEDESTAL Position the base in the desired point and adjust to the desired height using the feet the bolts are located on the four outer edges of the pedestal at the bottom Provide a power outlet on the rear of the pedestal that will be easy to reach once the installation is complete Fix the pedestal to the floor using strong steel screw anchors with an 8 mm diameter Fix the sliding base to the frame using the bolts Connect the exhaust outlet and air inlet as described in the previous section Then tilt the insert so that the wheels fit into the guide rails slide it until the exhaust auger coupling is completely inserted in the exhaust conveyor box Then use the socket wrench provided to turn the screw anticlockwise To check that the insert is correctly coupled with the base connect the plug to the power outlet the display should light up Fit the tank support as shown in Fig 10 Insert the support in the coupling provided N B When using our pedestal it is necessary to create an inspection window in the chimney that allows you to check the pellet level in the tank while filling it COMFORT MINI P80 INSTALLATION OExtraflame
34. ion of solid materials and any condensates located below the mouth of the exhaust pipe so that it is easy to open and inspect from the airtight hatch 16 ASSEMBLY AND INSTALLATION INSTRUCTIONS Windproof chimney cap N N lig lt 3m N N N N N N 3 5 N N Flue nspection N N N N Inspection N N N AS figure 7 figure 8 N N N N 747472929 gt gt gt N EM N 3m External insulated N Inspection 45 Inspection ZO Xy yy figure 9 figure 10 ASSEMBLY AND INSTALLATION INSTRUCTIONS 17 CONNECTION TO THE FLUE AND COMBUSTION PRODUCT EXHAUST VENTING The flue must receive exhaust from a single heat generator Direct discharge towards enclosed areas even when roofless is forbidden Direct discharge of combustion products must take place on the roof and the exhaust duct must have the features set forth in the section Chimney or single flue CHIMNEY CAP The chimney cap must meet the following requirements havean internal section equivalent to that of the chimney have a useful outlet section no less than twice the internal section of the chimney be constructed in such a way
35. ise stove combustion processes figure 43 attentions The removal of the partition jeopardises product safety and leads to the immediate invalidation of the warranty period In the event or wear or deterioration request a replacement from the assistance service the replacement does not come under the terms of the warranty as the part is particularly subject to wear and tear 40 CLEANING WIRING DIAGRAMS COMFORT MINI 24 2 21 mE 55 figure 44 WIRING DIAGRAMS 41 Numbering Description 00000000 6 Ignition electrode power supply terminal 8 Externalthermostat input terminal 9 Room probe input terminal 1 42 WIRING DIAGRAMS WExtraflame COMFORT 80 11 figure 45 WIRING DIAGRAMS 43 Numbering Description 6 ignition electrode power supply terminal ___8 External thermosta
36. lay shows a series of dashes Attempt to release alarm with stove still alarm cooling Display of the service centre telephone number 46 TABLE OF DISPLAY MESSAGES Chapter 13 OExtraflame INDICATOR LIGHTS Description Weekly Programmer function Room Thermostat function 1 Day Night temperature function Spark plug deactivation Flue gas motor operation Pellet load motor operation Cross flow fan operation Communication established between remote control and stove Not used TABLE OF DISPLAY MESSAGES This LED is on off when Weekly programmer is on off For all the settings regarding this function see the section Weekly programmer This LED is on off when the room temperature is lower higher than the temperature set To modify the temperature setting use buttons 2 and 3 during normal operation This LED is on off when the Day Night temperature function is on off To enable disable the Day Night temperature function simply hold down button 4 and press button 5 For all settings concerning this function see the Day Night temperature function paragraph This LED is on off when the spark plug is active inactive To reactivate the spark plug contact an authorised technician This LED is on off when the flue motor is running not running The LED is on off when the pellet loading motor is active deactivated During normal operation this LED flashes intermittent
37. ly The LED is on off when the cross flow fan is on off Each time you press a button on the remote control this LED should light up If it stays on it means that communication between the remote control and the stove is blocked To reset remote control operation contact an authorised technician Not used 47 WARRANTY EXTRAFLAME S p A reminds you that the manufacturer possesses the rights stated on Italian Decree no 24 from the 2 February 2002 and that the following warranty does not jeopardise these rights This warranty certificate by Extraflame S p A with headquarters in Montecchio Precalcino VI Via dell Artigianato 10 Italy extends to all components of the stove supplied by Extraflame S p A and includes free repair or replacement of any faulty part of the stove on condition that The defect is detected within 2 YEARS of the delivery date and is reported to an Extraflame S p A Technical Assistance Centre no longer than 2 months after its detection It is recognised as a defect by an Extraflame S p A Technical Assistance Centre The client will not be charged for any costs or expenses related to interventions carried out by the Extraflame S p A Technical Assistance Centre if these are covered by the warranty conditions WARRANTY CONDITIONS The warranty is considered valid on condition that 1 The stove is installed according to all related norms and to the information contained in the
38. ntrol and the stove Selecting the operating frequency During the first stove lighting it is necessary to establish a communication frequency between the remote control and the stove With this procedure it is possible to select one of 4 possible coding methods this also makes it possible to use more than one stove inside the same room without one interfering with the operation of the other The coding procedure is as follows 1 Disconnect the power supply from the stove Remove the batteries form the remote control Reposition the batteries in the remote control Press buttons 4 and 5 together for three seconds until CHOOSE UNIT appears on the display Use button 4 or 5 to select the desired coding from O to 3 Power up the stove The stove will emit two acoustic signals between the first and the second press button 1 for 1 second At this point the display will show EXTRAFLAME BW communication between remote control and the chimney is very disturbed or inaccurate the remote control can be directly connected to the device via cable as illustrated below Comfort Mini Comfort P80 figure 29 figure 30 figure 31 figure 32 figure 33 26 REMOTE CONTROL OPERATION GENERAL FEATURES The visual interface is given an LCD display with 24 characters on 4 lines
39. ollows a button 5 59 to scroll the days b button 4 to enable disenable ON OFF the first time period for that day To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter ut 5 gt START PROGRAM 2 Use buttons 4 and 5 to set the start of the second time period from 00 00 to 23 50 or to disable the function by setting it on off To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter ut 6 STOP PROGRAM 2 Use buttons 4 and 5 to set the end ofthe second time period from 00 00 to 23 50 or to disable the function by setting it on off To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter ut 7 gt DAYS 2 Used for setting which days of the week to enable disenable the time period set The procedure is as follows a button 5 59 to scroll the days USER MENUS 33 b button 4 to enable disenable ON OFF the first time period for that day To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter ut 8 gt START PROGRAM Use buttons 4 and 5 to set the start of the third time period from 00 00 to 23 50 or to disable the function by setting it on off To confirm and continue with programming p
40. ove using button 1 2 Set the desired heating power using buttons 4 and 5 3 Use the menu 1 button to go to the menu ROOM TEMP SET and set on MIN using button 4 4 Set the desired room temperature on the external thermostat e g 21 C At this point the external thermostat will control stove operation as follows Thermostat with closed contact gt the stove switches and operates at the power set and the display shows T ON Thermostat with open contact gt the stove goes to the minimum power even if the display shows the previously set value the display will then show MIN MECHANICAL THERMOSTAT OPERATION IN STANDBY MODE TO BE USED ALSO FOR REMOTE ACTUATOR The Standby function is used to further reduce pellet consumption by switching off the stove when the desired temperature has been reached As the temperature drops the stove will automatically switch on again 1 Set the desired temperature using buttons 4 and 5 2 Use the menu 1 button to go to the menu ROOM TEMP SET and set on MIN using button 4 3 Press button 1 for three seconds the display will show STBY At this point the thermostat will control the stove as described below Thermostat with closed contact gt the stove switches on and operates at the power set The display shows T Thermostat with open contact gt the stove switches off or stays off and the display shows STBY ATTENTION Using an external room th
41. plus 16 bars Transmission and reception capacity 4 metres in free air space Display of the operating status of the product Direct controls for switch on off power setting change LCD Display Button 4 Weekly programmer setting Button 1 Battery power supply two 1 5 AA batteries Dimensions 61 x 150x 120 Dx Lx W mm Button 5 KEYPAD Button 3 Button 1 ON OFF unblock Button 2 Pressing this button for two seconds enables the manual switch on off of the stove If the stove is in alarm status and therefore blocked the button is used for unblocking and subsequent passage to OFF status During the programming of the user parameters it is used to exit and return to the previous menu figure 34 Buttons 4 and 5 Parameter increase decrease On the main screen These buttons are used for regulating the operating power of the stove from a minimum setting of 1 to a maximum of 5 this value is shown on the upper display During modification of the user parameters the buttons are used for increasing decreasing the value of the parameter which is shown on the first line of the display Menu 1 3 and Menu 2 2 buttons These buttons are used for accessing and setting the user parameters DISPLAY The display message changes in relation to the status of the stove or the menu being display In resting status the display shows the following TIME The current time is shown The time is set within the we
42. r declines any responsibility contractually or extra contractually for any damage caused to persons animals or property by errors in installation adjustment and maintenance or by improper use After removing the packaging check to make sure that the contents are intact and complete If this is not the case contact the vendor from whom the appliance was purchased The electrical components of the stove to guarantee correct operation must only be replaced with original spare parts by an authorised service centre WARNINGS AND SAFETY OExtraflame General stove maintenance must be carried out at least once a year scheduled sufficiently in advance with the service centre The following safety precautions must be observed Do not allow the stove to be used by children or unassisted disabled persons Do not touch the stove if you are bare footed or if parts of your body are wet or damp Modifying the safety or adjustment devices without the manufacturers approval instructions is forbidden Never pull detach or twist the electrical cables coming out of the stove even if it is disconnected from the electrical power supply Avoid blocking up or reducing the size of the air vents of the room in which the stove is installed The air vents are critical for correct combustion Keep the packaging materials out of the reach of children and unassisted disabled persons During product operation the doo
43. r of the furnace must always be closed Avoid direct contact with parts of the appliance which tend to heat up during functioning Check for the presence of any obstructions before switching the appliance on following a long standstill period The stove has been designed to function in any climatic conditions even critical in particularly adverse conditions strong wind ice safety systems may intervene which switch the stove off If this happens contact the after sales service and under no circumstances disable the safety systems If the flue should catch fire use suitable systems to suffocate the flames or request help from the fire brigade TECHNICAL SPECIFICATIONS P80 550 789 Flue exhaust pipe diameter _ mm 80 outputpowertotheair outputpowertothewater kW 80 outputpowertothewater Recommended flue draught 10 10 Chimney draught at max useful heat output 12 12 Chimney draught at min useful heat output 10 10 Waterinle outletpipediameter Automaticdischargepipediameter Pumphead NN Nominal frequency Max accepted working water pressure _ EN SENI Tests carried out using wooden pellets as fuel with calorific value of 4 9 kW h kg The data stated above is a reference and not binding The manufacturer reserves the right to carry out
44. ress the menu 2 button To return to the previous parameter press the menu 1 button Parameter ut 9 gt STOP PROGRAM Use buttons 4 and 5 to set the end of the third time period from 00 00 to 23 50 or to disable the function by setting it on off To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter ut A gt DAYS ON Used for setting which days of the week to enable disenable the time period set The procedure is as follows a button 5 59 to scroll the days b button 4 to enable disenable ON OFF the first time period for that day To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button TO ENABLE DISENABLE the weekly programmer follow the procedure described at parameter 1 of the Set Clock Menu Note When the programmer is enabled the corresponding LED lights up on the display see Table of Display Messages Manual controls always have priority over the programming DAY NIGHT MENU The day night temperature function makes it possible to switch the stove on off automatically based on two selected temperatures This system enables you to select one temperature for daytime and one for night To access the parameters of the day night temperature function proceed as follows 1 Press the men 1 button gt the display will show ROOM TEMP SET 2 Press the men
45. ribed below is in progress and is accompanied by the corresponding indication on display D1 To reset the alarm press button 1 and hold for three seconds when the stove is Indicates the presence of an alarm completely cold If the light is flashing it indicates that the depression sensor is deactivated All resetting operations must be carried out by an authorised technician The flue gas motor is blocked The speed control probe is faulty No power supply to the flue gas motor The exhaust flue gas probe is broken 5 The exhaust flue gas probe is resetting operations must be carried out by an authorised technician disconnected from the board The cross flow fan is faulty Adjust the flow of pellets see Pellet Load Adjustment HIGH GAS TEMP Excessive pellet feed Other resetting operations must be carried out by an No power supply to the cross flow fan authorised technician 2 Check to make sure that the exhaust outlet and the The flue gas exhaust pipe is obstructed ia combustion chamber are clean The air inlet is blocked The combustion chamber isdiit Check that the air inlet is not blocked DEPRESSION y Check to see if the drawer is sealed properly The pressure sensor is faulty Check to see if the door is sealed properly The ash drawer is not closed properly Other resetting operations must be carried out The door is not closed properly All resettin
46. rvice centre When the adjustment has been made press button 1 to confirm and escape LANGUAGE MENU You can choose from the following languages available ITALIAN ENGLISH FRENCH GERMAN To access this menu proceeds as follows 1 Press the menu 1 button the display will Show ROOM TEMP SET 2 Press the menu 1 button again c the display will show CLOCK SET MENU 3 Press button 5 four times gt the display will show LANGUAGE 4 Confirm with the menu 2 button Use buttons 4 and 5 to select the desired language and confirm with the menu 2 button 36 USER MENUS ROOM THERMOSTAT MECHANICAL THERMOSTAT OPTIONAL N B Installation must be carried out by an authorised technician A thermostat can be placed in a room adjacent to the one in which the stove is installed Just connect a mechanical thermostat like those used for boilers following the procedure described below We recommend positioning the optional thermostat at a height of 1 50 m above floor level INSTALLING A MECHANICAL THERMOSTAT OPTIONAL N B Installation must be carried out by an authorised technician 1 Switch off the appliance using the master switch on the back of the stove 2 Disconnect the plug from the socket 3 Referring to the electrical wiring diagram connect the two thermostat wires to the respective terminals on the back side of the stove one red and one black MECHANICAL THERMOSTAT OPERATION 1 Light the st
47. sert support pedestal optional kit which is designed to secure the insert to the floor Description of the components Sliding base Guide rails Exhaust pipe Primary air inlet pipe Power outlet Adapter frame FITTING WITH SLIDING BASE Take the sliding base and place it in the existing fireplace Using chalk mark the base fixing holes on the floor of the fireplace Drill the holes for 8 mm steel screw anchors Drill a 60 mm hole in correspondence with the air inlet Theairinlet must be made outside the fireplace because it must not draw in overheated air Provide a power outlet on the rear of the insert so that the plug can be reached easily once the installation is complete Fix the base using the attachment screws Make the connection to the exhaust outlet and air inlet following the instructions previously described Then tilt the insert so that the wheels fit into the guide rails and slide it in until the exhaust auger coupling is completely inserted in the exhaust conveyor box 20 Chapter 6 Adaptation frame Sliding base with rails Primary air intake pipe figure 13 figure 15 COMFORT MINI P80 INSTALLATION Chapter 6 Finally open the fire door and use the socket wrench provided to turn the screw in the lower left hand corner clockwise To check that the insert is correctly coupled with the base connect the plug to the power outlet the display should lig
48. stove on or off as follows 1 Press the menu 1 button the display will show ROOM TEMP SET 2 Press the menu 1 button again c the display will show CLOCK SET MENU 3 Confirm with the menu 2 button When you have entered the programming function the display will show the following parameters Parameter 1 CLOCK DAY Used for setting the following values day1 day7 lt gt use buttons 4 and 5 to set the current day of the week When the current day has been set the weekly programmer function is automatically enabled To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter 2 gt CLOCK HOURS Use buttons 4 and 5 to set the current hour To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter 3 gt CLOCK MINUTES Use buttons 4 and 5 to set the current minutes To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button If you make an error in programming exit with button 1 and repeat the steps described above SET TIMER MENU The weekly programmer enables you to set three heating periods over the course of the day to be used for each day of the week The timetables for switch on off must be consecutive within the same day on a 24 hour basis from 0 to 24 and not straddling more
49. t channel must have a constant cross section Any changes in cross section are allowed only at the flue connection ASSEMBLY AND INSTALLATION INSTRUCTIONS 15 is forbidden to run other air feed channels or piping for utilities inside the exhaust channels even if they are oversized It is also forbidden to fit manual draught adjustment devices on the forced draught appliance CHIMNEY OR SINGLE FLUE The chimney or flue must meet the following requirements be sealed to combustion products waterproof and properly insulated according to the usage conditions be made of materials suitable to resist normal mechanical stress as well as heat and the action of combustion products and any condensates have a predominantly vertical layout with deviations from the axis no greater than 45 be situated at a proper distance from combustible or flammable materials by means of an air gap or suitable insulation material 20 cm Minimum 80 cm gt loor protection H figure 6 Flammable Non flammable objects objects preferably have a round internal section square or rectangular sections must have rounded edges with radius no less than 20 mm have a constant free and independent internal section have rectangular sections with a maximum ratio between sides of 1 5 The exhaust pipe should be equipped with a chamber for the collect
50. t input terminal ___ Roomprobeinputterminal Three pole network plug 44 WIRING DIAGRAMS Chapter 13 TABLE OF DISPLAY MESSAGES OExtraflame INDICATIONS Cause An attempt has been made to switch on a stove again when it has just been shut down normal shutdown or caused by an CLEANING WAIT Room Thermostat set at max value Room Thermostat set at min value An external thermostat has been connected The room thermostat probe disconnected from the board The room thermostat interrupted has probe is Stove is off and waiting to start again STBY COOLING No current on the general power supply hen the shutdown cycle is completed the stove BLACK OUT 9 PP will light again automatically The automatic cleaning of the brazier takes place at regular set intervals The automatic cleaning does not start if the stove is at the first power level DOOR OPEN The fire door is open Keep the door closed during normal operation Stove is off because of Day Night Temperature Function and waiting to start again Lack of communication between remote control and stove The automatic cleaning of the brazier is in progress BRAZIER CLEANING TABLE OF DISPLAY MESSAGES When the stove has just been shut down normal shutdown or caused by an alarm situation you have to wait until it is completely cold and then clean the brazier It is possible to re start the stove only after having carri
51. than one day Switch on 07 00 switch off 18 00 OK Switch on 22 00 switch off 05 00 ERROR 32 USER MENUS The programming procedure be carried out with the stove on or off and involves the following steps 4 Press menu 1 the display will show ROOM TEMP SET 5 Press menu 1 again gt the display will show MENU SET CLOCK 6 Press button 5 gt the display will Show CRONO SET MENU 7 Press menu 2 to confirm Once you enter the programming area the display will show the following Parameter ut 0 gt CRONO ON OFF Use buttons 4 and 5 to enable disable the weekly programmer To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter ut 1 gt START PROGRAM 1 Use buttons 4 and 5 to adjust switch on time for the first time period 00 00 to 23 50 or to disable it by pressing off To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter ut 2 gt STOP PROGRAM 1 Use buttons 4 and 5 to set the end of the first time period from 00 00 to 23 50 or to disable the function by setting it on off To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter ut 3 DAYS ON 1 Used for setting which days of the week to enable disenable the time period set The procedure is as f
52. ure that the tank is loaded with pellets the combustion chamber is clean the brazier is clean and free the fire door and the ash drawer are sealed the power cable is connected correctly the two way switch on the back of the stove is in position 1 2 Press button 1 for three seconds display D1 will show the message START During this stage the stove carries out an automatic check on the efficiency of each single electrical component When this cycle is completed display D1 shows the message IGNITION 15 the number of minutes for which the stove attempts the lighting stage decreasing by 1 every minute that passes NOTE The first time the stove is used even if the tank is loaded with pellets it is possible that the pellets are not distributed to the combustion chamber for the first 15 minutes because the worm screw for loading the pellets is empty If the stove has not developed a flame after the fifteen minutes have elapsed the display shows the message NO FLAME this case press button 1 for three seconds until D1 shows the message OFF Disconnect and reconnect the power supply using the rear master switch Then repeat steps 1 and 2 3 If points 1 and 2 are carried out correctly the stove will enter the START UP 07 stage 4 After the lighting phase the stove will enter the working phase and the display will show the room temperature heating power and stove status waRNINGI 1 NEVER USE FLAM
53. y our local Technical Assistance Centre This clause applies also to other countries with the exception of particular conditions agreed upon during the contract writing phase with the distribution agent abroad Replacement of parts does not result in warranty extension No compensation will be given for the period in which the product is out of use This is the only valid warranty and no one is authorised to supply other warranties either in the name of or on behalf of EXTRAFLAME S p A Recommended inspection extra charge Extraflame recommends having an operational inspection of the product by an Extraflame Authorised Technical Assistance Centre which will supply all the information regarding its correct use SERVICE UNDER WARRANTY The service request must be forwarded to the vendor RESPONSIBILITY EXTRAFLAME S p A shall not be liable for any direct or indirect damage caused by or depending on the product COMPETENT COURT For any controversy the competent court shall be the court of Vicenza Italy WARRANTY 49 QUALITY CONTROL Document that must be kept and produced if an intervention is requested under warranty Name Surname 1 1 Address Edad d 4 Postcode Eee 4121 12 24 0111 1411 City 1 1 Telephone 1 1 111 1 1

Download Pdf Manuals

image

Related Search

Related Contents

CELSIUS M4xx / R5xx / R6xx  Kenroy Home 32239ORB Installation Guide  Hiyoca 35 Operating Instructions  Honeywell COMMERCIALPRO TB7220 User's Manual  Instruction manual  FICHA DE PRODUCTO  Denon DN-X300 Musical Instrument User Manual  Considerações sobre preservação na  EFI PG170 Poster Glossy  Sensor y módulo ET para los programadores  