Home

User guide

image

Contents

1. 2007 0004 issue 6 ro I I Operator Chair Carl Foot and Heel Table of content 1 2 3 4 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 5 5 1 6 6 1 6 2 7 7 1 8 Operator chair Gafla ass ad ann au d e Ulja casa de ase d na ase do o 3 Important Before USE ssssssssssssssrssrssrsnrrsnn nns zdes n RR SH eas RR ARR ARR RR RA 3 MVS TAN AU ON mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmaHaHHH ii 5 Funchon and USE sisisi a 6 Produc IGENNNCANOMJADEJ M O 7 Wheels and stand cccccccsecccseeeceececeececeuseceuceseusessusessusessusensaees 8 Lift Stand ana WMA GO CVIC mm 8 Multi functional Safety Armrests kakaa kakaa kakaa 10 Foot brake 0220020000000 ena see K ee n nn 12 Important Before and during surgery eee 12 Charging the battery kaaa kaaa kaaa kaaa 13 MEDIACINJ IE BANENE mm 14 Cleaning and maintenance aaa 15 Maintenance and service aa kavana kakaa kaaa 16 ilija ee ie o Sana as ai o e ora 16 Warmngana other laDelS os anog sosa st kyadae dass sa 17 Statement of CE conformity 00aaava aka kakaa kaaa kaaa 17 Technical specificatiOns aaa anna anna 17 Disposal and recycling sssssessrssressrerrerrrsrrrrrrrrrr rerna rer r rr rr rn rann rn rn nan 18 Cini mmm me epova 18 ad cini 1 Operator chair Carl Thank you for choosing a Rini Operator chair Operator Chair Carl Foo
2. Relative air damp Atmospheric pressure Transport and storage Environment transport Temperature Relative humidity Air pressure Environment storage Temperature Relative humidity Air pressure w xh mm 350 x 300 460 x 420 130 x 360 530mm excluding brake pedal 580mm excluding brake pedal 500 800mm 370 N 37kg 12lbs 1200 N 120kg 265lbs 1100 kN 110kg 243lbs 24 V 2 9 Ah chargeable led accumulator charging time 12 hours Input 100 240 V 250 mA Output 24 V max 12 VA IP 40 5 C to 40 C 20 to 90 at 30 C 700 to 1060 hPa 10 C to 502C 20 to 90 at 30 C 700 to 1060 hPa 10 C to 502C 20 to 90 at 30 C 700 to 1060 hPa Operator Chair Carl Foot and Heel 7 1 INI Disposal and recycling Rini Operator chairs are manufactured using environmentally friendly materials mainly stainless steel aluminium PVC and plastics Rini recommends that the equipment is demounted as far as possible for recycling purposes Battery X The battery contains lead and must be disposed of as a car battery in accordance with local legislation X Electronic parts and cables are to be disposed of as electronic waste In accordance with local legislation Guarantee In accordance with Rini s general terms and conditions the warranty on the equipment is one year from date of purchase INI Jote F gels ngsv gen 3B SE 186 42 Vallentuna SWEDEN Phone 46 8 594 771 70
3. Fax 46 8 92 92 79 info rini se www rini se
4. handle The armrest should not be loaded by a weight exceeding 20kg or 44Ibs Foot brake The foot brake is situated on the right hand side of chair Activate the foot brake by pressing down on the pedal Release the brake by pulling up the pedal with your foot Important Before and during surgery This chapter describes the order in which the 120 00102 00 01 Operator chair should be adjusted to achieve the best level of efficiency and ergonomic use of the chair 1 Whilst seated in the chair adjust the height of the chair to achieve a 90 angle of the legs The feet shall have the whole sole against the ground during the adjustment See image at next page 2 Adjust the seat and backrest to a comfortable position 3 If necessary fine tune the height of the seat 4 Adjust the armrests to a comfortable surgical position rini Operator Chair Carl Foot and Heel o Move the chair against the operating table to achieve optimal access to the patient and foot pedals 6 l necessary fine tune the position of the armrests to achieve a satisfactory surgical position 7 Lock the wheels using the foot brake 8 Adjust the height of ihe operating table to achieve optimal access to the patient F Always activate the foot brake in order to avoid unintentional movement of the chair Charging the battery The battery comes fully charged The charging socket is located on the top of the contr
5. ini distributor Operator Chair Carl Foot and Heel 120 00102 00 01 e The column is mounted at the wheel base and all cables are already connected e Place the seat at the cone which is located at the top of the column i e Put the back at the seat Adjustment control Armrest bracket e Put the armrest into the armrest bracket and tighten NOTE The adjustment controls shall point out from the chair Before use for the highest security of personal and equipment Read this manual or gain required education from Rini INI Operator Chair Carl Foot and Heel 4 Function and use Adjustable armrests Aside from the battery charger no other accessories are available for i echa ballery or can be used with the Operator Foot brake chair 120 00102 00 01 Height adjustment controls See chapter 7 for technical specification 4 1 Operator Chair Carl Foot and Heel Product identification label The label is placed at the stand under the seat Ad rini KA F gels ngsv gen 3B SE 186 42 Sollentuna Phone 46 8 594 771 70 Fax 46 8 92 92 79 Product Code 120 00102 00 Serial number 000 01 External charger FW7218M 24 Protective Class IP24 SWL 1100N Mode of operation 5 Max 3min 57min Standard EN 60601 2 46 Made in Sweden 2006 0072 Issue 1 7 Label description severe danger to the patient personnel or the system i The
6. ni 4 3 2 4 3 3 Operator Chair Carl Foot and Heel Adjusting the height of the chair Carl Heel The height of the Operator chair Carl Heel can be adjusted by pushing with the heel at the control buttons which are located at the base between the front wheels When seated in the chair push with the heel backwards at the left button to move the seat position up and the right button to move it down If both buttons are pushed simultaneously there will be no movement The standard seat height range of the 120 00102 00 01 chair is 500 800mm or 19 7 31 5in Other ranges are available The chair should not be used by people exceeding a weight of 110kg or 243lbs Adjusting the seating position The chair is equipped with a one hand grip adjustment for seat and backrest positions The adjusting handle is situated just below the seat on the right hand side of the chair The adjustment should be done whilst seated in the chair Turn the handle in a counter clockwise direction to release the seat and back rest Adjust the seat and back rest to a comfortable position before tightening the handle by turning it clockwise Operator Chair Carl Foot and Heel 4 4 INI The backrest height adjustment locking clip is placed on the backrest bar Adjust the backrest by pressing the locking clip to the right The backrest can now be adjusted by hand to a suitable position The backrest locks to i
7. o avoid damage from self discharge New batteries can be ordered from your local distributor or Rini Please make sure that the new battery pack is fully charged before use Used batteries are recycled as car batteries Cleaning and maintenance No part of the equipment is normally in contact with the patient and the armrests are draped during surgery Recommended disinfectants Part Product Other information Seating and Virkon 1 concentration other parts of art including most leather or nylon disinfectants without alcohol Disinfectants containing alcohol cannot be used due possible to dehydration of the leather Foot control and Noedischer Dekonta 1 3 concentration other electronic CCOTRADE RW 0 5 concentration parts Including most disinfectants Operator Chair Carl Foot and Heel 2 1 Bd rini Recommended cleaning agents Part Product Other information Padding wheels and Water and soap Use damp cloth frame Parts of metal and lacquered surfaces Electronic parts Water Use damp cloth hand control control box and battery Battery charger Water Use damp cloth Maintenance and service Periodic maintenance Monthly Hinges and joints Use non corrosive standard instrument spray Armrest locking Use non corrosive standard lubrication spray system Accessories Please contact your local distributor or Rini for information about accessories available for
8. ol box at the rear of the chair A fully charged battery will operate the chair for approximately five days during normal working conditions To guarantee the battery is fully charged it should be allowed to charge for 12 hours When the battery has reached full capacity charging automatically turn to trickle charge to avoid overcharging ini Operator Chair Carl Foot and Heel 4 8 Replacing the batteries The batteries are mounted inside the control box at the rear of the chair To replace the batteries unplug the control box connectors and remove the four screws These can be reached underneath the chair 1 Unplug the connectors N Carefully place the chair on its side gt Remove the four screws holding the control box 4 Use a small screwdriver to open the cover o Open the cover by hand BA rini 4 8 1 A 99 Operator Chair Carl Foot and Heel 6 Remove the batteries and unplug the connectors Insert the new batteries and reconnect them accordingly Batteries exposed to impact must be checked by your distributor or Rini Maintenance of the batteries Batteries have a limited lifecycle and have to be replaced after approximately four years of use under good operating conditions Frequent and heavy discharges will reduce the batteries lifecycle For optimum performance the batteries should be charged weekly and must be charged at least every third month t
9. ons before use Please read this manual carefully and understand how to use the product before you start Before you unpack the product check the packaging e Make sure that the packaging has not been damaged during transport Report any damage immediately to the transport company and your local Rini representative Remove the packaging e Lift the parts out of the packaging o 1 pc base o 1 pc seat o 1 pc backrest o 2 pc armrests Bd rini Warning Be careful when lifting the chair off the pallet The JAN chair is heavy and may cause injury Avoid bumping it This can cause material damage Operator Chair Carl Foot and Heel e Remove all the packing material such as plastic tape etc from the chair Warning Do not use sharp tools when removing the packaging material This can cause damage e Make sure that the delivery includes all ordered parts Contact your Rini sales representative if you find any discrepancies Before using the product please check the following e The product has not been damaged in transport e All cables are connected and the chair installed as described in this manual e The battery is fully charged see chapter 4 7 Please contact your local Rini sales representative if you have any concerns 3 Installation When you get the operator chair delivered it is not ready to be used It has to be mounted accordingly to this manual or according to agreement with your R
10. t and Heel The operator chair offers the highest level of comfort ergonomic design and efficiency for daily patient work Our chair has been designed to optimise on outstanding ergonomics quality and durability for surgeons and similar professionals The chair is delivered with Rinis unique safety armrests Rilis which makes it possible to adjust the required position with high precision By safety reasons are the armrests requiring a two handed movement to be adjusted They are easily adjusted in height and angle The plate is able to slide and rotate can manage heavy loads The backrests load angle at the Carl chairs are self correcting Angle at seat and backrest can be adjusted simultaneously with a simple hand grip The stable wheel base in Rinis design is a robust construction based on a rigid H stand with four large wheels accurate electrical height adjustments and a foot brake All vouch for a safe workplace with long durability The operator chairs are specially designed for micro surgery and developed in cooperation with operators and surgeons in Sweden and international Rini is constantly improving existing products and developing new ones Consequently we value the professional user s point of view so don t hesitate to let us know your opinion about any of our product lines 2 Important Before use To ensure patient safety and the life of the product it is M important to observe the following instructi
11. ts current position when the locking clip is released Multi functional Safety Armrests The unique Rini safety armrests which are a feature of Rinis Operating Chairs have multiple height positions in order to accommodate an optimal ergonomic working position The armrests have five different adjustment functions e The armrest is equipped with a rail making it possible to slide the armrest back and forth in any direction Loosen the black locking wheel to enable the arm plate to slide back and forth Tighten when correct position is set It can also rotate around the black locking wheel allowing maximum flexibility and ergonomic relief It facilitates when the operator is about to sit or rise from the chair and simultaneously maintain sterile hands FIN Operator Chair Carl Foot and Heel By pushing buttons the armrest can be adjusted to an optimal working position To release the armrest you need a two handed grip one hand to move the armrest plate up and down while simultaneously pushing one of the buttons with the other hand Then move the armrest to the desired position or angle and release the button Use the locking handle to set the appropriate armrest height The width between the armrests can be set using the handles under the seat Operator Chair Carl Foot and Heel 4 6 INI e There are two handles on each side under the seat Normally the armrests are set in front
12. warning sign is used when there is a risk of K Type B equipment as per EN 60601 1 Degree of protection against electric shock SWL Safe Work Load the chair should not be used by people exceeding the label specified weight Mode of The electrical height adjustment shall only be operation used totally 3 minutes within each 1 hour Standard EN 60601 2 The product is made for the operating theatres 46 environments Operator Chair Carl Foot and Heel 4 2 4 3 4 3 1 CINI Wheels and stand The stand is designed as a robust H shaped construction to guarantee high stability and long term durability The chair is equipped with four large wheels for mobility The rear wheels are lockable by a foot controlled brake Lift stand and lifting device The lifting device is a battery powered motor unit consisting of a motor a control unit and a battery pack Foot controls are used to adjust the height of the chair Adjusting the height of the chair Carl Foot The height of the Operator chair Carl Foot can be adjusted by pushing the foot control buttons on the stand above each front wheel When seated in the chair push the left button to move the seat position up and the right button to move it down If both buttons are pushed simultaneously there will be no movement The standard seat height range of the 120 00102 00 01 chair is 500 800mm or 19 7 31 5in Other ranges are available BA ri
13. your equipment Spare parts Please contact your local distributor or Rini for information on spare parts available for your equipment Repairs The equipment should only be repaired by Rini or a Rini authorised service centre or engineer Systems to be repaired under warranty must be sent to an authorised Rini service centre Warning Any unauthorised repairs or modifications to the equipment may result in equipment malfunction Furthermore this will render the warranty null and void Safety The Operator chair must only be used in accordance with its intended purpose as described in this manual Incorrect use or deviation from the safety instructions could lead to damage of the equipment and or personal injury This manual should always be available near the Operator chair Please observe the warning labels on the equipment BA cini 6 1 6 2 Operator Chair Carl Foot and Heel Warning and other labels A The warning sign is used when there is a risk of severe danger to the patient personnel or the system Statement of CE conformity The Operator chair 120 00102 00 01 conforms to CE according to MDD 93 42 EEG Approved according to standard EN 60601 2 46 and EN 60601 1 Technical specitications Dimensions Back support Seat Armrests Total width Total length Seat height Weight Maximal load Safe working load Battery Battery charger Working Environment Temperature range