Installation manual KIMA ZONE 50

image

Contents

1. Installation manual KIMA ZONE 50 a ae ee Version 3 LCD Display Red increase temperature Programming button Blue decrease On Off temperature switch ZONE 50 is an electronic thermostat for electric underfloor heating system with external floor sensor ZONE 50 can be installed in standard wall box or flush mounted on the wall with an external frame box ZONE 50 controls and regulate the floor temperature to achieve the best room comfort ZONE 50 is using the adaptive PWM and PI technics to to give the best performance and to extend ZONE 50s lifetime ZONE 50 should not be used to eliminate over temperatures in the floor construction The only way to eliminate overtemperatures is to design the floor construction with the right W m and compensate for the floor constructions thermal insulation and the Wattage per linear meter Warm Floor Heating Cable or Wattage per square meter Warm Floor Mat If the buildings insulation properties is poor it can be compensated with another external heat source If ventilation heat pump air condition are chosen as the external heat source it is important that the temperature setting for this heat sources will not be lower than the floor temperature this will save energy The under floor heating construction should never be exposed to high temperatures to elimi nate the risk of fire The worst situation will be when the construction have a high power output per sqm floor and the floor construction i
2. T0104010 Rev 111121 Technical specifications ZONE 50 Voltage 230 VAC 15 50 60 Hz Users manual ZONE 50 with a floor sensor are the best and an easy way to control and regulate the Max output resistance load 3600 W underfloor heating system and to achieve the best comfort Underfloor Heating system are Max current 16 Amp always slow reacting system and that depends on the thickness of the floor construction Relay Normally open Thicker cement based floor constructions gives also a possibility to accumulate heat Energy consumption lt 1W If the building have poor insulation value and the heat losses are considerable is it pos Switch 2 pole 16 Amp sible to lower the energy consumption by using the Economy function with an external Control range 0 50 C switch or external timer see technical specifications Preset temp floor sensor Economy function fixed value Economy function control signal Frost protection fixed limittemp Frost protection control signal Housing Classification Category overvoltage Min Max surrounding temp turned on Min Max storage temp Limit surrounding airpollution Length sensor cable Max extension sensor cable Floor sensor resistance Dimensions 25 C 5 0 in the display 5 C LCD display minus 5 C 230 VAC 10 C 230 VDC rectified serial connected diode IP21 Class II III Pulse voltage 4kV acc to IEC 60664 1 0 40 C 20 50 C Class 2 normal aircirculation domestic hom
3. atures If their will be no heat see fault finding list BR949A15a BRO49A 16a es ce p mi Fig 1 Fig 2 Documentation Installations manual Users manuals and any other documents for the floor construction should be filed near by the switchboard together with Warranty documents that can prove that it has been an authorized installer that are responsible for the installation Environmental disposal ZONE 50 is an electronic product and should therefor be returned to any envi ronmental approved depo stations Products marked with this symbol can t be disposed together with the normal household waste It should be delivered to a waste collection centre in accordance with the local regulations Faultfinding ZONE 50 Fault tracing should be done by KIMA authorized fault finder The floor will not be warm A Check that the cables have been connected in the right way and the terminal screws are tight B Check the voltage on terminal 1 and 2 C Check that the switch on ZONE 50 is switched on Check the voltage on terminal 3 and 4 when the Heating Cable Heating Mat is on and the LED light is lit as said in paragraph 5 Measure the electric current with a clamp meter and compare it with the technical specifications for the Heating Cable Heating Mat D Disconnect the Heating Cable Heating Mat and check the total resistance and the insulation propertie
4. e 3 0 m 50 m with min 1 5 mm conductor se separate table below H 82 W 82 d 38 mm ZONE 50 can only operate with a resistive load such as a heating cable or a heating mat an external contactor should be used if the load is larger than 3600 W or a 3 phase construction Sensor resistance at diffrent temperatures ZONE 50 factory set value are 5 0 LCD display 25 0 C floor temperature ZONE 50 LCD display controls between 0 10 To change setting press blue or red button and the LCD display will change 0 1 up or down It is possible to change the LCD display to degree C operating mode see Programming With ZONE 50 their is also the possibility to change the temperature reading in the LCD display Offset compared with the actual floor temperature to match measured room temperature maximum offset 8 C up or down This will only work when ZONE 50 is opera ting in the degree C mode ZONE 50 is maintenance free Programming To program parameter values press and hold the programming button for 3 seconds In the LCD diplay Lcd nU will be displayed At first Lcd for 1 second then nU ready to be changed To continue with the programming with the next parameter press the programming button If no button is being pressed within 30 seconds it will return to it s operating mode Temperature Sensor ohm Pos Parameter Mode eee Factory setting Possible to select call
5. e a j LED display 0 10 Leda a Hone 0 C 38000 or degree C peice j ee 10 C 23300 2 Offset oFF 0 8 20 C 14800 30 C 9700 Warranty Name property VY escent Stns tc cepted toes tose d inches ceeecea lps aceetcta ad tecestoeneth gland eee eet nintendo Installation Company name aiccccccacccscssees lt innscscsctosccecntnccobetebesvbens devtensssensesiassededsndsasnsdestaondousadsla deabseectawnisietnnniehecdtie Tnstallatiom Adresi epsona atcha ac aac i r S a EEE Installation Company adresinin ae niis EA EE E AE E E E ceed ene ee eet Installer Company tph no sec ssscescccsee i ctucscaceccccceatutendetencedeccinedteaateaehsiaicandideloaissapueldbiaay dusvpiadieiiawisbeenlba ied Installed in type of room Se ee eee ae eae eee ae ee Semen ene Ce eee a one Purchasing place Company Mamie sa ccccccccsivecssstevecconssatcszescussolantaleccecvescacecvaciniainaracatilacoinisssaadnndausicnessodanseecaononbsen Installed date ae omaniecnmiaen vasa ascueagenutansaes angen E EO Purchasing date atrccs cee tosecee sessed neato uesn my edemdniaeamnudenucuaaainE Installed WS a tccthseceh cesta ll ca cheered crnecvslncech i r E oN Watt Installed floor SMA SS icin tNaerceis sakeethcdeices onthe uerianniiah anes trciubaawacede sqm Installed Wattage per sqm floor ceeeccccccsssssssssssssssssssssssssssssssssssssssssssssssissiiinnueenees Watt sqm Where Documents are filed ccccccccssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssnsssssssssssss
6. m from the wall It is important that the sensor will not be placed in an area were the heat can be thermally blocked with fixed or movable furniture wardrobes kitchen cupboards etc If needed the floor sensor cable can be extended with a separate ordinary 1 5 mm instal lation cable maximum length see technical specifications The floor sensor should not be installed in the same electrical conduit pipe as the heatingcables heatingmats cold tail or any other electrical cables If the floor sensor is connected to a cable with metallic sheath Don t earth the metallic sheath Economy function Day or Night setback Lowering the floor temperature with a preset value see Technical specifications with an ex ternal signal This function doesn t need to be used if not needed The external timer should be installed on a suitable place for example at the switchboard or a manual switch that could be installed next to ZONE 50 The timer or switch can control more than one thermostat at the same time Important to use the right control signal see technical specifications LED light will be green when the economy signal is active and red when the heatingcable heatingmat is energized see Fig 1 Frost protection Frost protection will maintain the floor room temperature at a low temperature see techni cal specifications This function doesn t need to be used if not needed The external timer should be installed on a suitable place for example a
7. s and compare them with the recorded values from the installation that should be filed near the switchboard and compare it with the technical specifications E If the measured electrical values are correct according to the technical specifications and the construction doesn t get warm enough the problem could be that the heat losses are greater than the input power and the reasons could be cold spots PS Do not increase the power out put that will instead increase the risk of fire and also shorten the ageing properties of the Heating Cable Heating Mat Analyze the total building constructions insulation properties and try to find any cold spot that can cause the problem If the floor construction is a concrete slab on the ground check the moisture that could be a great problem due to better heat conductivity Another problem could be that their is a could area under the floor construction and that s why it important to insulate the construction well F Disconnect the floor sensor on terminal 5 6 and there will be an error code in the LCD display E1 the LED light will flash red once The same will happened if terminal 5 6 are shortened G Check the floor sensors resistance and compare it with the technical specifications The reading should only change with the temperature H If ZONE 50 are turned on and the surrounding temperature are lower than 20 C ZONE 50 will turn the relay off and when the temperature increase over 20 C it
8. s thin with a good thermal insulation and the floor surface will be covered with a carpet or any other good thermal insulating material The maximum allowed temperatures is depending on the surrounding material and regulated by the electrical standards regulations and directives Maximum temperature in a floor construction according to electrical standards is 80 C The general maximum temperature for combustible material is 80 C Maximum operating temperature for Heating Cable or Heating Mat see the products technical specifications The maximum temperature for water membrane are quite low 50 C see the producers technical specifications ZONE 50 complies with the directives for electrical safety and EMC compatibility ZONE 50 are CE marked and complies with the following standards EN 61000 6 2 EN 61000 6 3 EN 60730 1 and 60320 2 9 ZONE 50 should only be used when the whole installation complies with electrical standards regulations directives and KIMAs installation manuals ZONE 50 should only be installed by authorized installers If ZONE 50 have been exposed to violence or got damaged it should be carefully controlled by qualified personnel before it will be connected to the mains Installation floor sensor It makes it easier if the floor sensor is installed in an end sealed electric conduit pipe if it needs to be replaced The floor sensor should be installed in an open floor area between two heating cables about 0 5
9. ssssssssssscessscssessssceceeseeeeeeeeees Functional test Thermostat is operating when the temperature settings are changed up and down Yes No Measured current when energizedC oou cccccccssssssssssssssesssssscescsssssssssusssessssseeeessnsssssssnsuessssseecssessssssssnseesesseeeees Amp Drawing or photo showing thermostat and floor sensors with measurement distance from wall location Signature property owner nnna aaa anan Signature installeri www kima com
10. t the switchboard or a manual switch that could be installed next to ZONE 50 The timer or switch can control more than one thermostat at the same time Important to use the right control signal the signal should be connected via a rectifier diode see technical specifications See Fig 2 Installing ZONE 50 1 Open the plastic front cover and unscrew the screw The thermostat should not be opened in any other way 2 Connecting cables see fig Terminal 1 Live L Terminal 2 Neutral N Terminal 3 4 Heaingcable Heatingmat Maximum Load 3600W 16Amp Terminal 5 6 Floor sensor Terminal S Control signal from external timer or switch to operate Economy function Day or Night setback or Frost protection if decided to use PS Before the Heating Cable or Heating Mat is connected to ZONE 50 the resistance and insulation properties should be checked See Heating Cable or Heating Mat installation manual 3 Install ZONE 50 with the frame against the wall or over a wall box and fix it with screws Fit the covers www kima com 4 Don t turn the heating on to early before concrete or liquid concrete have cured enough See manufactures specifications 5 LED light will be red when the Heating Cable Heating Mat is energized Depending on the thickness of the floor construction and how low surrounding temperature are it will take longer time to achieve set temperatures If the heat losses are high it could be a problem to achieve set temper
11. will turn on again I If the temperature in the thermostat will be greater than 70 C it will turn the relay of for 10 minutes so the temperature will decrease and the LED light will flash red five times and a error code E5 will be presented in the LCD display J Contact the distributor ZONE 50 has been purchased from The floor is energized all the time a Check that the cables have been connected in the right way and the terminal screws are tight b Disconnect the floor sensor on terminal 5 6 and there will be an error code in the LCD display E1 the LED light will flash red once The same will happened if terminal 5 6 are shortened c Check the floor sensors resistance and compare it with the technical specifications The reading should only change with the temperature d Contact the distributor ZONE 50 has been purchased from Problem programing ZONE 50 see Users manual Error codes in the LCD display E1 Sensor fault The sensor are shortened or disconnected The LED light will flash red once E5 Overheating The temperature will be higher than 70degree C in the thermostat and the relay will be switch off for 10 minutes so the temperature will decrease and the LED light will flash red five times Programing ZONE 50 See Users manual Warranty Installation should be done by an authorized installer according to regulations directives and KIMAs installation manual Time of Warranty see KIMA Warranty INS

Download Pdf Manuals

image

Related Search

Related Contents

User Manual - E&P Hydraulics  Retrouvez toutes les informations en cliquant ici  Samsung E2202 1.77" Black  Installation Manual  BIOS User`s Manual  el manual de instalación  Gunnar Optiks Anime  Westinghouse 52-Inch Specification Sheet  PAL User Manual Installation and Operation GC PAL PAL GC-xt  Benq LCD Monitor FP91E  