1. water adjustment knob completely flow If the fluid is still insufficient remove the tip and inspect if fluid comes out of the handpiece If yes replace the tip The handpiece is Check that the fluid flow is sufficient recommended 20 ml min overheated If problems cannot be resolved according to this troubleshooting guide please contact your dealer for further service support 18 Amdent 6 Technical data Input voltage different models 24 Vac 50 60 Hz or 24 32 Vdc Ambient temperature Transport amp storage 40 C to 70 C 40 F to 158 F Operation 10 C to 40 C 50 F to 104 F Relative humidity Transport amp storage 10 to 100 Operation 10 to 95 Water consumption 10 ml min 50 ml min Further technical descriptions on request The manufacturer provides the qualified technical staff of the dealer or distributor with necessary informa tion for service of the equipment limdent 7 Warranty and Declaration of conformity 7 1 Warranty The manufacturer hereby warrants that the Amdent Scaler will be free from defects arising from faulty materials or workmanship Limited Warranty This Limited Warranty does not cover the ultrasonic scaling tips This Limit ed Warranty applies only if the Amdent scaler and or the Amdent ultrasonic scaling tips are installed and used by the customer according to the instruc tion furnished herein is connected to a proper power supply is not misused or a
2. your application please contact your local dealer or place of purchase General requirements Installation and service of the product is only to be performed by authorized service personnel The product must be connected to electricity supply and water supply meeting the requirements specified in the Technical data section on page 19 Contraindications Do not use the scaler on patients with cardiac pacemakers The scaler may disturb the function of the pacemaker General precautions e The product is not suitable for use in the presence of flammable gases e Systemic antibiotics must be used appropriately and with the advice of a medical doctor e Only use the product in combination with Amdent scaler tips e Ifthe handpiece tubing is damaged or worn out it must immediately be replaced to avoid exposing the user or the patient to electric hazard RAlmdent Safety notices in this manual Warning indicates a potentially dangerous N situation Non observance may lead to death or injury WARNING Caution indicates a potentially harmful situation Non observance may damage the equipment gt Caution Note indicates a situation where special notice should be observed Note limdent 1 Unpacking 1 1 1 2 3 General content of delivery Handpiece incl tubing Electronic unit installed inside the unit ErgoGrips type and quantity depending on what was ordered Tip wrenches type and quantity depen
3. at the ErgoGrip as this can make the removal difficult 3 Clean and sterilize the equipment according to the General cleaning procedure section on page 15 3 2 Built in endo additional instructions Endodontic treatment Activate the endodontic mode The power is reduced over the entire setting range to approximately half the power used in the scaling mode 4 Cleaning and maintenance 4 1 General cleaning procedure After each treatment I Wipe off the handpiece and the hose with a soft cloth Use a 45 isopropanol and detergent solution 2 Wash the ErgoGrip the tip and the tip wrench and autoclave according to the clinic s routines WARNING Do not use nickel tita nium files since they easily break at high frequencies The operator should be aware of that ultrasonic instruments with small diameters are subject to breakage at any time If not used correctly or with too much power or force the instrument WILL break Caution Do not sterilize any scaler accessories using dry heat or chemical autoclaves This may damage the material Do not immerse the handpiece in any fluid Moisture may permeate into it and damage the ultrasonic generator limdent 4 2 Autoclave temperatures 135 C 275 F 121 C 248 F Q Tip LJ ErgoGrip Basic LI Endo file LI ErgoGrip Ultra Q Tip wrench UL ErgoGrip UltraLight 4 3 Maintenance Handpiece Inspect the handpiece hose daily to insure that the equ
4. bused and there 1s no evidence of tampering mishandling neglect acciden tal or wilful damage or modifications The customer must contact the authorized dealer from whom the Amdent Scaler and or ultrasonic scaling tips were purchased to request repair or replacement under this Limited Warranty This Limited Warranty is void if service or repair 1s performed by persons not authorized by the manufacturer Normal wear and tear is specifically exclud ed from this Limited Warranty Manufacturer disclaims any express warranty not provided herein and any implied warranty guarantee or representation as to suitability for any particular purpose performance quality and absence of hidden defects and any remedy for breach of contract which but for this pro vision might arise by implication operation of law custom of trade or cour se of dealing including implied warranties of merchantability and fitness for a particular purpose except as provided in this limited warranty The manufac turer further disclaims any responsibility for losses expenses inconveniences special indirect secondary or consequential damages arising from ownership or use of the product 20 RAlmdent 7 2 Declaration of conformity The manufacturer hereby declares that the Piezo Ultrasonic Scaler Built in all models Class I type B according to EN60601 1 conform to the essential requirements of the Medical Device Directive 93 42 EEC with reference to t
5. ding on what was ordered Tips type and quantity depending on what was ordered Note This chapter describes the components of the delivery and can be used as a check list when unpacking Contact your place of purchase if anything is missing For a description of the fea tures of the equipment read the Equipment description section on page 7 RAlmdent 2 Equipment description 2 1 General description The Amdent Built in series is a range of piezo ultrasonic scalers that are sup posed to be mounted on a dental unit The ultrasonic power can be regulated to provide a wide range of settings The Built in is equipped with one of the handpieces Ergo Basic Ergo Ultra or Ergo UltraLight The tips can easily be changed during the treatment and can also be cleaned and autoclaved together with the individual ErgoGrips in the same procedure 2 2 Built in endo additional description The model Built in endo is equipped with an endo switch and has a special low power range available when performing endodontic treatments 2 3 Handpiece Ergo UltraLight additional description The light will illuminate when the foot control is depressed limdent 2 4 Symbols Conforms to CI UL Std 2601 1 Sec ed N us Cert to CANICSA C22 2 ISTES NO 601 1 M90 9800163 C Eon Attention Consult accompanying documents Medical electrical equipment classified by ETL with re spect to electric shock fire mechanical and oth
6. er speci fied hazards in accordance with UL 2601 1 second edition and the Canadian Standard CAN CSA C22 2 No 601 1 M90 Compliance label indicating compliance with the Medical Device Directive 93 42 EEC Withstands autoclave temperature 135 C 275 F Withstands autoclave temperature 121 C 248 F Amdent Type B equipment according to the degree of protection against electrical shock Fuse Input Output Please do not throw the equipment into the domestic refuse Please use the return and collection systems available in your country for the disposal of this product limdent 3 Operating instructions 3 1 General Mode of operation Note With cooling fluid the scaler can be operated These instructions are valid for the Ergo Basic continuously Ergo Ultra and Ergo UltraLight handpiece Without cooling fluid the scaler may only be operated for shorter periods and the maximum operating time is 2 minutes followed by a cooling down period of 8 minutes Operating without cool N ing fluid is recommended only for special clinical treatments for example crown removal and thixo Caution Without cooling fluid the tropic cementing when cooling of the treated sur maximum operating time is 2 minutes followed by face is not necessary When performing root canal A A treatments the canal must be filled with fluid of 8 minutes Operating the scaler for more than 2 minutes may cause Before treat
7. gs there will be no spray Amdent How to use the scaler The side of the tip end shall be applied to the tooth so that the movement of the tip is parallel to the surface of the tooth The first 2 mm of the tip are the most efficient Place the tip on the tooth surface before activating the foot switch Normal scaling rarely requires more than 50 power level However hard to remove calculus might require a higher power setting Ensure that contact between the tip and the tooth sur face is maintained during scaling Keep moving the tip slowly back and forth and let the instrument do the work Use short and long strokes so that the whole sur face of each tooth is scaled The tip is normally aimed towards the toothpocket To keep the tip working parallel to the surface of each tooth it is important to follow the anatomy of the tooth With the correct power setting appropriate pressure against the tooth approximately 20 grams but not ex ceeding 50 and the tip operating parallel to the surface treatment will be gentle quiet and efficient If during the treatment a squeaking sound is heard loud and dominating the pressure against the tooth might be too low or the tip not parallel to the surface of the tooth limdent After treatment 1 Screw off the tip counter clockwise with the tip wrench 2 Squeeze the ErgoGrip gently at the top and at the same time slide it off the handpiece Do not squeeze too hard
8. he following harmonized standards EN 60601 1 1990 with Al and A12 1993 A2 1995 and A13 1996 Classification Medical products Class Ia C Eons 21 limdent NOTES 22 NOTES lAmdent 23 aimdent Good Vibrations Box 1009 SE 149 25 Nyn shamn Sweden Tel 46 8 520 131 20 Fax 46 8 520 185 74 E mail info amdent com www amdent com 1 gt oO m N N oO N N oOo
9. ipment is in good condi tion without mechanical damage Amdent Tips When a tip is bent altered scratched or worn more than 2 mm it will lose per formance and must be exchanged Check the tip length weekly by com paring the tip to the template below a STARNE WARNING A tip that is bent altered scratched or worn more than 2 mm will lose per fo formance and must be 2mm exchanged Prolonged use may cause tip breakage and injury to the patient 37 2mm The operator should be aware of that ultrasonic 33 instruments with small diameters are subject to breakage at any time If not used correctly or 2mm with too much power or force the instrument WILL break 38 2mm Le limdent 5 Troubleshooting The tip does not Check that the tip is firmly tightened vibrate properly Check that the tip is not worn more than acceptable according to the tip template in the Maintenance section on page 17 If the problem is not resolved try another tip preferably unused Built in endo additional information Check that the scaling mode is activated The tip threads If the tip threads are damaged blow off the handpiece threads with don t fit smoothly compressed air and try another tip preferably unused Throw away the onto the handpiece damaged tip If the problem still remains contact your dealer for service instructions because the handpiece threads might be damaged Insufficient fluid Open the
10. la mdent Good Vibrations User s Manual Bullin PIEZO ULTRASONIC SCALER Amdent Important Read this manual carefully before using the product How to read this manual This manual contains instructions for several models of scalers Each chapter starts with a section with general instructions for all models which is followed by sections with additional information concerning each model First read the ge neral section and then proceed to the section that applies to your model of scaler If there are any questions regarding the contents of this manual please contact Amdent AB Trademarks Amdent is a trademark owned by Amdent AB Manufacturer Copyright Amdent AB Copyright 2005 Amdent AB All rights Box 1009 reserved The contents of this manual SE 149 25 Nyn shamn Sweden may be changed without notice No part Telephone 46 8 520 131 20 of this manual may be reproduced in Fax 46 520 8 185 74 any form or by any means without per E mail info amdent com mission in writing from Amdent AB Internet www amdent com Printed in Sweden October 2005 C E0413 Contents SOO acco s cera EE EEE 4 1 UNPGCK INO criin anaE E E AEAEE 6 1 1 General content Of delivery minessmsesssressrrersrrsssrrrsrsrsrrrrnrrrrnrrrrnr rr r rr en rr rr nan 6 2 Equipment description ssss ssssssssrsarsrss rsarssrn nn nn rnn rn RAR ARR ARR RARE RA 7 2 1 General description c msssssessressressrrsrrsrrrerrenrrrsrrrnr ers nns rr rr rr inr r
11. ment overheating and damage to the handpiece 1 To rinse the water line hold the handpiece over the bowl Depress the foot switch and allow the water to flow for 30 seconds 2 Gently slide the ErgoGrip on to the handpiece 2 4 Carefully align the tip and screw it clockwise into the handpiece Use the tip wrench to firmly tighten the tip to the handpiece WARNING A tip that is bent altered scratched or worn more than 2 mm will lose per formance and must be exchanged Prolonged use may cause tip breakage and injury to the patient The operator should be aware of that ultrasonic instruments with small diameters are subject to breakage at any time If not used correctly or with too much power or force the instrument WILL break 11 limdent Scaling 1 Set the ultrasonic power to maximum position 2 Keep the handpiece over the bowl and depress the foot control to activate the scaler 3 Adjust the ultrasonic power according to the specific tip requirement 4 Keep the patient s lips cheeks and tongue out of 12 the way of the tip and perform treatment accord ing to the following instructions A WARNING New tips are not sterile upon delivery Sterilize before use according to the clinic s routines Keep the patient s lips cheeks and tongue out of the way of the acti vated tip since contact may cause burns Note At low power settin
12. r r rr RR ARR RA nro n 7 2 2 Built in endo additional description immmsssessresrsersrsresrrrrrrrrrrrrnrrn rer rer r innan 7 2 3 Handpiece Ergo UltraLight additional description smmsmssrssessresrerrrsrrnr ees 7 2A OVI ONS segnor rii ena mesar bs LEN NN ON bitna 8 3 Operating instructions ussssssssssssssrrssrrrnrrrrnrrrrn nns RAR RARE R RARE RR RAR iene 10 STN EE E A E EEE ETE 10 3 2 Built in endo additional instructions nssnsssessressrersrsrrrsrresrrrrrrerrrrrrrnr erna nn 15 4 Cleaning and maintenance cccccseeeeeseeeeeeeeeeeeeeeeeeeeeeeeeeseeeeeneesees 15 4 1 General cleaning procedure cccccsssceceeececceseeeceeseeseeeesseseesseeeeeees 15 4 2 Autoclave temperatures ccccccecccsccceeeceseeceeeceeceueecseesaeesseeseueeneeess 16 4 3 Maintenance mososseseesrsessesserrenrrenrrssrer rar rrrr rss rer ran rar rr RAR R KRK RR KKR KKR RKS KKR RR RR nn 16 9 Tr ubleSNOOUNOG sssini a aE SRK a aa 18 6 CHIC AN CAG senmana E E 19 7 Warranty and Declaration of conformity ccsceeeseseeeeeeeeeeeeenees 20 L WN a nestor ni sen 20 7 2 Declaration of conformity eiisccice sats cxncnndecsnandateccnonedacesaunndadaiesnenedsencennisact 21 limdent Safety Intended use This scaler is designed for dental purposes It is designed for removal of tar tar or calculus on teeth and other dental work where the ultrasonic vibration is beneficial Do not use it for applications where it is not intended If you are unsure about