Home

User's manual Primor 2000 / Level 15

image

Contents

1. 9 Power supply and battery change The lock is power supplied by one 9 V block battery alkaline no rechargeable batteries When battery voltage is insufficient after entering the code a warning tone occurs repeatedly and the red LED flashes alternately Change the battery as quickly as possible The programmed codes stay valid during battery change Always dispose used batteries in an environmentally friendly way Fig 1 Input unit Primor RO 8 04 05 2012
2. Ce WITTKOPP User s manual Primor 2000 Level 15 Content 1 General instructions 1 1 Liability notes 1 2 Operating notes 1 3 Notes on safety 2 Visual and acoustic signals 3 Input unit 4 Operating the lock 4 1 Opening 4 2 Locking 5 Programming the lock 5 1 Master and user codes 5 1 1 Programming a user code programme 1 5 1 2 Changing the master or user code programme 0 5 1 3 Deleting a user programme 3 5 2 Time delay and opening window 5 2 1 Adjusting the time delay and opening window programme 9 5 2 2 Opening with activated time delay and opening window 5 2 3 Deleting the time delay programme 9 5 2 4 Opening with the instant opening code 6 Operation blocking programme 2 7 Overview users programme 7 8 Testing the system programme 5 9 Power supply and battery change co CO NN N OBO Oo Oo fF HR KR BR FBP Ww Ww WB WwW NY NY NY NY WN Carl Wittkopp GmbH Errors and omissions excepted User s manual no 9999 116 1 CeWITTKO PP Primor 2000 Level 15 1 General instructions e Please read the operating instructions carefully before activating the lock 1 1 Liability notes e We don t assume liability for malfunctions due to incorrect operation use of force or inappropriate handling In cases of damage to property or valuables which are due to incorrect locking of the safe we also do
3. n t assume liability e If your safe however does not open correctly with the following instructions please contact the manufacturer of the safe 1 2 Operating notes e Assess a person to administer the lock This person will be the master Up to 9 users can be programmed They receive PIN 1 9 PIN Personal identification number The code of the user 9 is also the instant opening code when a time delay is activated e When programming the electronic lock has to be opened e If the lock is not opened or closed within 3 seconds after entering the code the electronics switch off Re enter the code and repeat the process e When the time between touching keys exceeds 10 seconds the process of programming and entering is deleted The old code or programmes stay valid e Every correct input while entering the code is confirmed by an acoustic signal and flashing of the red LED These signals will not be considered in this instruction e The red LED flashes during the whole process of programming These signal will not be considered in this instruction e Never use force e Do not open the lock case otherwise you compromise the function of the lock and warranty will be void 1 3 Notes on safety e For your security change the factory code 1 2 3 4 5 6 7 immediately e For your new code do not use any personal data like birthdays or any other data which could be known by knowledge of your person e After entering the new code the elect
4. ndow e g AJi2J s 4J s sj 7 Input unit Primor RO The lock is opened Turn the input unit clockwise within 3 seconds into opening position e An active time delay can be interrupted by pressing any key 5 2 3 Deleting the time delay programme 9 The time delay can only be deleted within the opening window The opening window runs after deleting the time delay for the last time 1 Enter your 7 digit code e g mastercode Gangoor 2 Wait until the end of the time delay 3 Opening window starts 4 Press and hold the key 9 until the red LED flashes permanently EE a 5 Enter your 7 digit master code e g aesae EE 6 Delete the time delay ofo 7 Delete the opening window og EE l 8 Delete the time delay again o o 9 Delete the opening window again oj EE D 04 05 2012 Primor 2000 Level 15 CeWITTKO PP 5 2 4 Opening with the instant opening code The instant opening code is meant to bypass the time delay The instant opening code is assigned to user 9 A corresponding user code has to be activated The code that is entered first must not be identical to the code of user 9 vA X 1 Enter your 7 digit code e g mastercode Cejas EE 2 Time delay starts xy 3 Enter your 7 digit instant opening code e g eje joj ojo ejo EE Input u
5. nit Primor RO Turn the input unit clockwise within 3 seconds into opening position The lock is opened 6 Operation blocking programme 2 Only the master can enable or disable all user codes at the same time Have user codes been disabled the lock can be opened only with the master code id xX 1 Press and hold the key 2 until the red LED flashes permanently 2 EE m 2 Enter your 7 digit master code e g Jiejia EE m 7 Overview users programme 7 This function provides an overview of the number of free or already occupied users Only the master can perform this function Z x 1 Press and hold the key 7 until the red LED flashes permanently 7 EE 2 Enter your 7 digit master code e g aesae EE a 3 Enter the user PIN that has to be checked e g users 3 5 6 3 5 ion ee ocoupied 4 End the query o LE 04 05 2012 7 CeWITTKO PP Primor 2000 Level 15 8 Testing the system programme 5 Press every number once A functional key will be confirmed by a double signal A key that was not identi fied is confirmed by a long signal and the functional test is aborted The system has to be checked Ya bd 1 Press and hold the key 5 until the red LEDs flash permanently 5 EE 2 Press every key in its order of appearance Oefa J o an
6. rogramme 1 ral x The master is able to program a user code but not vice versa 1 Press and hold the key 1 until the red LED flashes permanently J EE 2 Enter your 7 digit master code e g Haagen an 3 Enter the user PIN e g user 3 3 EE D 4 Enter the new 7 digit user code e g Wooo ES E ED is 5 Re enter the new 7 digit user code e g ooo ES ET E EE e A new user code will be allowed only if the code is differing in two places by a single digit from an existing code e Should the new code be denied restart the process of programming 5 1 2 Changing the master or user code programme 0 Z 1 Press and hold the key O until the red LED flashes permanently o an 2 Enter your old 7 digit code e g user code ojo ES ES E E an 3 Enter your new 7 digit code e g 5 6 7 8 oJ iJ 3 an 4 Re enter your new 7 digit code e g s 6j7J 8 oJ ij 3 an i e A new user code will be allowed only if the code is differing in two places by a single digit from an existing code e Should the new code be denied restart the process of programming 5 1 3 Deleting a user programme 3 s x The master is able to delete a user but not vice versa 1 Press and hold the key 3 until the red LED flashes permanently 3 an 2 Enter your 7 digit master code e g OJ EE 3 Enter
7. ronic lock should be opened and locked several times with the safe door opened e After each locking doublecheck if the safe is closed 2 Visual and acoustic signals Signal Explanation Comment S Right code xX Wrong code or code denied a Short signal Es Long signal LED flashes every 10 seconds Blocking time is active i LED flashes every 2 seconds Time delay is active ELL Battery warning Battery should be changed soon 2 04 05 2012 Primor 2000 Level 15 CeWITTKO PP 3 Input unit Primor RO 2 5 118 0 WITTKopp 4 Operating the lock 4 1 Openin p g ei x 1 Enter the 7 digit code e g master code CJs EE m Input unit Primor RO Turn the input unit clockwise within 3 seconds into opening position The lock is opened e After 4 consecutive wrong code inputs a blocking time of 5 minutes occurs During this blocking time the red LED flashes every 10 seconds and every input is accompanied by a long signal tone After the blocking time has passed 2 further incor rect inputs will restart the blocking time 4 2 Locking Input unit Primor RO Close the door at the safe and turn the input unit counterclockwise into locking position The lock is closed 04 05 2012 CeWITTKO PP Primor 2000 Level 15 5 Programming the lock 5 1 Master and user codes 5 1 1 Programming a user code p
8. the user PIN of the user who has to be deleted e g user 1 OJ EE 4 04 05 2012 Primor 2000 Level 15 CeWITTKO PP 5 2 Time delay and opening window Only the master can program or delete the time delay Time delay 01 99 minutes time to wait until the lock can be opened Opening window 01 19 minutes within this time window the master or the user can open the lock with his code Code input beginning of the time delay Wait during the time delay Opening window re enter code 5 2 1 Adjusting the time delay and opening window programme 9 p M 1 Press and hold the key 9 until the red LED flashes permanently EE acest 2 Enter your 7 digit master code e g ulej sjaje EE E 3 Enter the time delay e g 20 minutes 2Jo 4 Enter the opening window e g 10 minutes Ujio EE D 5 Re enter the time delay e g 20 minutes 2Jo 6 Re enter the opening window e g 10 minutes Ujio EE e The time delay can be increased at any time It can be reduced only during the opening window 04 05 2012 5 Ce WITTKOPP Primor 2000 Level 15 5 2 2 Opening with activated time delay and opening window 1 Enter your 7 digit code e g mastercode AJ2Js 4J s 6J7 2 Wait until the end of the time delay 3 Opening window starts 4 Re enter your 7 digit code within the opening wi

Download Pdf Manuals