Home
User manual of ZWP15 controller
Contents
1. User manual of ZWP15 controller Contents LDesGHpliOM an A O AAA AGA W A OE EA 2 2 Mmstallati n 0f ZWP15 ComtrOllet ss aoi W O W Aa wd aib W 3 3 Conttollerprogramming adni zlo sonra O nA PCO APO bis 4 3 1 Adding device to network INCLUDE function 5 3 2 Associating device with a pair of buttons on the controller ASSOCIATE function 3 3 Associating another controller with the network LEARN MODP wed 3 4 Deleting device from a pair of controller buttons on the controller DELETE function 8 3 5 Excluding device from the network EXCLUDE function 9 3 6 Restoring default settings in the controller DEFAULT function 10 3 7 Removing SECONDARY controller from the network su 10 3 8 Special function ASSAIN A ROUTE ssa oswoic EE 11 A Techical parameters zaa i Gai EA AO Rak 11 SAREMOLS COMMONS i ad Rai OSW A O R GIO NIA R AE ASO WGA 12 6 Battery replacement ccsocosuccsseesssecssveserseueotoueseetensexcnsucertycerescopensanunssinesodte TETEE ATEENSKE ENEE 13 ENV ATAY Semi Renan REP OE RADOWO GOA nn 14 12 06 01 NC811 GB 1 16 2012 FAKRO 1 Description The ZWP15 remote control enables remote control of electronic accessories compatible with the Z Wave system e g ZWS12 or ZWS30 motors for operating FAKRO roof windows The ZWP15 controller can operate up to 15 devices separately The single button in the upper section No 3 Figures 1 allows sele
2. Note When moving the device within the network it is recommended to delete it from the controller s memory first deleting from a pair of buttons section 3 4 an then deleting it from the network section 3 5 and re adding after installation in new workplace 12 06 01 NC811 GB 4 16 2012 FAKRO 3 1 Adding device to network INCLUDE function Adding a device to the Z Wave network is possible only via PRIMARY controller every single brand new controller is set as a primary controller by default In each network there is always only one primary controller and any other added to it is identified as SECONDARY The procedure of device adding to the network is presented in Figure 2 r FR SN 1 Press In Ex button once 2 The controller is signalizing its 3 Press P button on the device readiness for adding a new device and hold it for 0 5 sec see to the network external LEDs on Installation Manual for 10 sec 4 The controller is signalizing that 5 Programming error two external the device has been successfully diodes flashing for app 2 3 sec added to the network middle LEDs on for app 2 3sec Note In the new version of the controller stopping of each procedure is possible by pressing of IN EX buttons In the older version it is necessary to wait 10 sec until the moment of signalling the error by the controller or resetting it by removing batteri
3. www fakro com tel 48 18 444 0 444 fax 48 18 444 0 333 12 06 01 NC811 GB 16 16 2012 FAKRO
4. All devices taking part in the below procedure must belong to the same network must have the same HOME ID It is possible to use the controller ZWK1 ZWK15 ZWP15 to configure the device being outside the direct range of the network transferring NODE info of the device which is to be controlled to the controlling device memory controller to archieve that use ASSAIN A ROUTE Rysunek 8 1 Press the sequence of buttons on the controller t within 1 5sec i press the IN EX button and then 1 the SEL button 2 Readiness to transfer NODE INFO to other p SS controller diode 1 2 lights up for 10 sec I mena ain 3 Press the programming button on the controller 1 sec TX for 1 second 4 Admitting NODE INFO to the memory is signalled by the controller diode 3 4 5 Start the procedure of device adding to the group on the target controller Associate function Press the sequence ofbuttons on the controller within 1 sec press the IN EX button on the controller briefly and then one of the pair of buttons 6 Wait for confirmation of the execution trans fer NODE INFO 7 Confirmation of calling up the function on the main controller diodes 1 2 3 4 FAKR Note In the new version of the controller stopping of any procedure is possible by pressing of IN EX buttons In older version it is necessary to wait 10 sec until
5. distance between the primary controller and controller being added e controller already belonging to another network It is necessary to perform DEFAULT procedure with it and repeat associating with the network 12 06 01 NC811 GB 7 16 2012 FAKRO 3 4 Deleting device from a pair of controller buttons on the controller DELETE function This function deletes from controller s memory the device associated with a pair of buttons on a selected channel However it does not remove the device form the Z Wave network This function is accessible from PRIMARY and SECONDARY controllers The procedure of device deleting form a pair of controller buttons is presented in Figure 5 1 Select remote control channel 2 Within 1 5 sec press 3 The controller is signalismg through which the device to be In Ex 1 button twice and then readiness for device deleting three removed is operated the button from this pair of buttons LEDs on for 10 sec which operates the device to be removed e g 2 e Nes 4 Press P button on the device and hold 5 The controller is signalizing 6 Programming error it for 0 5 sec see Device Programming successful device deleting three LEDs flashing for app 2 3 Manual LEDs on for app 2 3 sec sec Note In the new version of the controller stopping of any procedure is possible by pressing of IN EX buttons In older version it is nece
6. cting one of the five channels No 2 Figures 1 with which devices can be associated The fifth channel is signalized by all 4 LEDs The ZWP15 controller is equipped with a two way Z Wave radio communication radio module For communication the Z Wave module exploits radio wave frequency of 868 42 MHz In Figure 1 there is presented a general view of the ZWP remote control with description of available buttons and signaling Dimension ZWP15 1 Functional button In Ex A 157 mm 2 Active channel signaling 3 SELECT button for changing channels B 38 mm 4 Operating buttons pair No C 19 mm 5 Operating buttons pair No Il 6 Operating buttons pair No Ill Figure 1 ZWP15 remote control 12 06 01 NC811 GB 2 16 2012 FAKRO 2 Installation of ZWP15 controller The holder of ZWP15 controller should be attached to the wall or other permanent building element by means of two screws driven into cylindrical plugs inserted into openings drilled in the wall 1 Screw the bottom section of the holder to the wall using the included screws which are driven into plugs inserted into the drilled openings LT 2 Mount the upper part of the holder 3 Place ZWP15 controller on the holder 12 06 01 NC811 GB 3 16 2012 FAKRO 3 Controller pr
7. er version it is necessary to wait 10 sec until the moment of signalling the error by the controller or resetting it by removing the batteries Figure 6 Excluding device from Z Wave network Programming error may be caused by e failure to press the programming button within 10 seconds from controller signaling its readiness for excluding the device from the network e long distance between the controller and device being excluded Note Each device physically deleted from the network e g damaged shall be deleted from the controller s memory PRIMARY SECONDARY that is first deleted from a pair of buttons section 3 4 and then deleted from the network 3 5 Appropriate implementation of procedures aims to provide optimal communication between devices Disconnecting the device without deleting it from the controller s memory will result in longer time of reaction of devices on commands and faster running out of batteries In case of necessity of deleting damaged device which deleting from the controller s memory is not possible it is recommended to re configurate the whole network all devices Configuration of the new network begins with restoring the controller to factory settings DEFAULT function and then EXCLUDE function is used and next we go further to the section 3 Controller programming Note When moving the device within the network it is recommended to delete it from the controller s memory first dele
8. es Figure 2 Adding device to Z Wave network Programming error can be caused by no button being pressed within 10 seconds from the controller signaling its readiness for adding a new device to the network e long distance between the controller and device being added e the device already belonging to other network It is necessary to use EXCLUDE function and repeat the procedure of device adding to the network 12 06 01 NC811 GB 5 16 2012 FAKRO 3 2 Associating device with a pair of buttons on the controller ASSOCIATE function Associating the device with a pair of buttons on the controller which has been already included in the Z Wave network according to section 3 1 makes it possible to operate the device This procedure can be carried out on the primary and secondary controllers The procedure of associating the device with buttons is presented in Figure 3 XS 1 Select channel on the 2 Within I sec press controller through which the In Ex 1 button once and readiness for associating the device will be operated then device with a pair of buttons on the button from this pair pf the controller three LEDs on for buttons which will operate the 10 sec device e g 2 4 Press P button on the device and 5 The controller is signalizing that the 6 Programming error hold it for 0 5 sec see Device device has been successfully associated LEDs flashing for app 2 3 P
9. first controller PRIMARY or performing LEARN MODE again on the SECONDARY controller already associated with the network Primary Secondary LJ IF n x3 1 Press In Ex button once on 2 Press In Ex button on the 3 The controller is signalling the PRIMARY controller controller LEARN MODE which assigning with the network two is to be added to the network three LEDs on as presented in the times within 1 5 sec picture for app 10 sec Primary Primary J 4 After few seconds the controller is signalizing that associating with the 5 Programming error two external network has been successfully completed two LEDs on as presented in LEDs flashing for app 2 3 sec the picture for app 2 3 sec Note In order to operate devices from the Secondary controller it is necessary to perform ASSOCIATE function look section 3 2 Note In the new version of the controller stopping of any procedure is possible by pressing of IN EX buttons In older version it is necessary to wait 10 sec until the moment of signalling the error by the controller or resetting it by removing the batteries Figure 4 Associating another controller to Z Wave network Programming error can be caused by e failure to enter LEARN MODE on the controller being associated with the network within 10 seconds from primary controller signaling its readiness for adding a new device to the network e long
10. ntrollers is activated after longer more than 0 5 sec holding of close button and causes the accessory launching into the closing direction until releasing of close button Start to open in ZWP ZWK controllers is activated after longer more than 0 5 sec holding of open button and causes the accessory launching into the opening direction until releasing of open button Stop closing opening in ZWP ZWK controllers is activated after releasing of open button or close button with earlier issued command Start closing Start opening In practice it means that in order to stop the roller shutter at any position it is necessary to press particular button and hold until reaching of the desired position or launching the roller shutter into desired direction by short pressing of appropriate button and then stopping it by pressing longer than 0 5 sec and then releasing of the same button 1 U SoS SRG i NU 25 god dad gd of Sea e265 CJ m 12 06 01 NC811 GB 12 16 2012 FAKRO 6 Battery replacement With standard controller use four times a day the battery should theoretically ensure correct device functioning for the period of 2 years assuming that the programming procedure has been performed only once Multiple device programming shortens the battery life 1 Remove the back
11. ogramming In order to operate FAKRO electronic accessories featuring the Z Wave system by means of the ZWP15 controllers it is necessary to 1 Add the device to the Z Wave network INCLUDE function see section 3 1 and 2 Associate the device with a selected pair of buttons on the controller with which user wishes to operate the device ASSOCIATE function see section 3 2 In one Z Wave network there can be included a maximum of 232 devices i e controllers electronic accessories for FAKRO roof windows as well as other electronic devices Note Each device physically deleted from the network e g damaged shall be deleted from the controller s memory PRIMARY SECONDARY that is first deleted from a pair of buttons section 3 4 and then deleted from the network 3 5 Appropriate implementation of procedures aims to provide optimal communication between devices Disconnecting the device without deleting it from the controller s memory will result in longer time of reaction of devices on commands and faster running out of batteries In case of necessity of deleting damaged device which deleting from the controller s memory is not possible it is recommended to re configurate the whole network all devices Configuration of the new network begins with restoring the controller to factory settings DEFAULT function and then EXCLUDE function is used and next we go further to the section 3 Controller programming
12. rogramming Manual LEDs on for app 2 3 sec sec Note In the new version of the controller stopping of any procedure is possible by pressing of IN EX buttons In older version it is necessary to wait 10 sec until the moment of signalling the error by the controller or resetting it by removing the batteries Figure 3 Device associating with selected pair of buttons on controller Programming error can be caused by no button being pressed within 10 seconds from the controller signaling its readiness for associating a new device with the network e long distance between the controller and device being added e device already belongs to another network or it has not been associated with any network It is necessary to perform EXCLUDE function on the device and repeat INCLUDE and ASSOCIATE functions 12 06 01 NC811 GB 6 16 2012 FAKRO 3 3 Associating another controller with the network LEARN MODE Associating further controllers with the network makes them being categorized as SECONDARY Associating a controller with the Z Wave network consists in sending data to it from the PRIMARY controller The procedure of controller associating is presented in Figure 4 In order to assure the best possible communication within the network and after each its modification including or removing a device associating another controller with the network should be performed after associating all devices with the
13. section of the casing 2 Replace the battery with a new on 3 Reinstall the back section of the casing and screw it down in 12 06 01 NC811 GB 13 16 2012 FAKRO 7 Warranty The manufacturer guarantees correct device functioning It also undertakes to repair or replace the device if its defects result from material or structural faults The warranty period is 24 months from the purchase date fulfilling the following conditions Installation has been performed by an authorised individual as per manufacturer recommendations Seals remain intact and no unauthorised structural changes have been made The device has been used in accordance with its intended use as per user manual Damage is not a result of improperly made electrical system or atmospheric phenomena The manufacturer is not liable for damage which occurred as a result of improper use or mechanical damage In case of failure the device must be submitted for repair with a Warranty Card Defects revealed within the warranty period will be removed free of charge no longer than 14 days after accepting the product for repair Warranty and post warranty repairs are performed by the manufacturer i e FAKRO PP Sp z 0 0 Quality Certificate Device Signature stamp of installing person 12 06 01 NC811 GB 14 16 2012 FAKRO 12 06 01 NC811 GB 15 16 2012 FAKRO FAKRO PP Sp z o o ul W gierska 144A 33 300 Nowy S cz Polska
14. ssary to wait 10 sec until the moment of signalling the error by the controller or resetting it by removing the batteries Fig 5 Deleting device from a pair of buttons on the controllers Programming error can be caused by e failure to press programming button within 10 seconds from controller signaling its readiness for deleting the device from selected pair of buttons e long distance between the controller and device 12 06 01 NC811 GB 8 16 2012 FAKRO 3 5 Excluding device from the network EXCLUDE function Excluding the device from the Z Wave network is possible only with the use of PRIMARY controller e g ZWP remote control In each network there is always only one primary controller and every other is categorized as SECONDARY The procedure of device excluding from the network is presented in Figure 6 x2 1 Press In Ex button twice 2 The controller is signalizing its 3 Press P button on the device and within 1 sec readiness for excluding the device hold it for 0 5 sec see Device from the network two middle Programming Manual LEDs on for 10 sec 4 The controller is signalizing that the 5 Programming error two device has been excluded successfully middle LEDs flashing for app 2 3 two external diodes on for app 2 3 sec sec Note In the new version of the controller stopping of any procedure is possible by pressing of IN EX buttons In old
15. the moment of signalling the error by the controller or resetting it by removing the batteries Note Information on how to call up the function ASSAIN A ROUTE by the use of devices of other manufacturers will be found in their instructions for the particular devices Figure 8 Function ASSAIN A ROUTE 4 Technical parameters Technical parameters Power supply CR2450 3V DC Working temperature 5 C to 40 C Working range Up to 40 m Working frequency 868 42 MHz 12 06 01 NC811 GB 11 16 2012 FAKRO 5 Remote control Note Each command sent from the remote control to the accessory is preceded by a period of accessory awakening This period usually lasts about 0 3 s In practice this manifest in delayed reaction lasting for about 0 5 s When the accessory remote controlling 5 commands can be used e Close in ZWP ZWK controllers is activated after short about 0 5 sec pressing of close button on the controller and causes the roller shutter launching into the closing direction until the motor reaches the end position which means that the accessory is completely closed Open in ZWP ZWK controllers is activated after short about 0 5 sec pressing of open button on the controller and causes the accessory launching into the opening direction until the motor reaches the end position which means that the accessory is completely open e Start to close in ZWP ZWK co
16. ting from a pair of buttons section 3 4 an then deleting it from the network section 3 5 and re adding after installation in new workplace 12 06 01 NC811 GB 9 16 2012 FAKRO 3 6 Restoring default settings in the controller DEFAULT function Restoring default settings of the controller leads to the following information being deleted from its memory e network to which SECONDARY controller has been added e devices in the network for PRIMARY controllers e devices associated with pairs of buttons for PRIMARY and SECONDARY controllers After performing DEFAULT procedure the SECONDARY controller will be set as PRIMARY 1 Within 1 5 sec press 2 The controller is signalizing restoring default In Ex button twice 1 and then settings alternate flashing of middle and SELECT button 2 once external LEDs for app 1 2 sec Note In the new version of the controller stopping of any procedure is possible by pressing of IN EX buttons In older version it is necessary to wait 10 sec until the moment of signalling the error by the controller or resetting it by removing the batteries Figure 7 Restoring default settings in controller 3 7 Removing SECONDARY controller from the network Removing this controller from the network consists in restoring default settings with the use of DEFAULT function 12 06 01 NC811 GB 10 16 2012 FAKRO 3 8 Special function ASSAIN A ROUTE Note