Home

Service manual and spare parts list

image

Contents

1. No Part No Description 1 TS 61080 Element 2000 W 2 E 150020 Fan motor 3 0110155 Temperature sensor 4 TS 61026 Over heat protection 120 C 5 TS 61027 Over heat protection 100 C 6 504142 Relay LC1 D12P7 230 V 7 TS 61082 Disturbance filter 8 0110154 Humidity sensor 9 TS 61083 Condenser 10 0110150 Main control board PODAB 2010 CD Electrical drawing 10 60 80 22 Si avdud ca 04 A TH vI PX TOLN Aas HS rio oNI oNY4 TOLN auda 1 91 NY4 43lv3H NIVW eV TV 69 TAX o 021 TLP 4e OT ev Ws ol eg LViLSOWdS NOILdO gt LVLSOWsS INAW3A14 SNILY aOLSINA3 AOSNIS ALIGI NOILdO gt NY3 1X3 AVI NV4 AV LHILI HLIMS OAIIN HILIMS OXIIW 1934 AV YOLOW N SOLOW N JA da JA v4 VA cu Ed E D SSOO0CHOHTLTZYEE OU 00 09 1 U a PODAB 2010 11 SERVICE SUPPORT Phone 46 31 752 01 00 Fax 46 31 752 01 50 E mail parts podab se www podab se Ww PODAB AB PODAB Ekonomivagen 9 436 33 Askim SWEDEN Tel 46 0 31 752 01 00 Fax 46 0 31 752 01 50 E post sales podab se www podab se OPODAB 2010 01 18
2. n kr a ean A PODAB E lt Service manual and spare parts list Drying cabinet TS 62 Ww PODAB Thank you for choosing our drying cabinet TS 62 We hope that it will be of great use for you PODAB 2010 2 Contents Dimensions and specifications Measurements Technical information Main control board Service menu Parameter list Explanation of parameters Error codes Spare parts list Cabinet Top Electrical drawing A HA 00 SI 0 01 GI 11 PODAB 2010 Dimensions and specifications Measurements mm 640 1200 N AA ry p s N e 0 2 Technical information Loading capacity kg up to 8 kg Evacuation connection mm 125 Drying capacity g minutes 78 Hanging length m 17 Drying time minutes 40 Maximum evacuated air m3 h 240 Electrical connection 3 N 400 V 50 Hz Element effect KW 6 0 Total effect kW 6 3 Energy consumption kg kWh 0 6 Weight kg 145 Part No 131025 For 6 kg dry weight cotton with 53 residual moisture The cabinet has a cool down phase of 15 minutes when the heating phase is completed OPODAB 2010 4 Main control board The drying cabinet TS 62 can be customized by adjusting the main control board s parameters The following parts describe how these parameters can be reached and the meani
3. 0 00 0 30 00 10 22 PAUSE TIME 0 00 0 30 00 10 23 COIN ON OFF OFF 24 SIGNAL TYPE PLS N 0 N 0 25 WORK TIME 000000 h 26 TEST LOOP ON OFF OFF 27 CLEAR E CODE YES OPODAB 2010 Explanation of parameters P 1 LANGUAGE TS 62 is delivered with English display text as standard Choose between Swedish English and French P 2 PRESET Choice of product in which the main control board is used Shall be in mode TS 62 or OFF OFF means that the main adjustments for the cabinet have been adjusted by some of the other parameters If the parameter is in mode TS 62 the cabinet goes back to the main adjustments P 3 DEGREE UNIT The degrees can be displayed in Celsius or Fahrenheit P 4 MIN TEMP Setting of minimum temperature level in manual mode means that the warmth is completely shut off Choose this al ternative if the customer wishes a pure airing program The in terval can be altered is affected of MED TEMP The highest possible degree to be chosen depends on which value param eter No 5 has Setting from the factory is 40 C P 5 MED TEMP Setting of medium temperature level in manual mode Choose temperature level depending on value for both MIN and MAX TEMP Setting from the factory is 60 C P 6 MAX TEMP Setting of maximum temperature level in manual mode Low est temperature level to choose is depending on which value parameter 5 has Setting
4. S PODAB 2010 Error codes Disp Reason Activity E T1 Control board gets no signal from the tempera ture sensor Control that the sensor is connected correctly on the main control board and that the cable from the sensor to the board is intact E T3 The control board s elec tronically overheat protec tion has been activated The error code is gener ated if the temperature is risen above 100 C twice within 30 minutes Control that the fan mo tors are working as they should Also control the temperature sensor and that the cable from the board is intact E H1 The control board gets no signal from the humidity sensor Control that the sensor is connected correctly on the main control board and that the cable from the sensor to the board is intact Spare parts list Cabinet No Part No Description 1 TS 61084 Door left 2 TS 61085 Door right 3 TS 61086 Handle 4 TS 61087 Service door left 5 TS 61088 Service door right 6 TS 61081 Lamp Bulb 7 70107001 Door switch 8 TS 61089 Magnet list 9 0110151 Display control board 10 TS 61090 Cover glass 11 0110152 Keypad 12 011053 Sticker user manual 13 TS 61091 Hanging frame 14 TS 61092 Hanging level 5 arms 15 TS 61093 Hanging level 4 arms 16 TS 61094 Foot Detailed view A PODAB 2010 Top
5. automatic will register the laundry as dry quicker If the K value is decreased the dry ing time is prolonged in automatic mode Parameter K VALUE PR1 affects automatic program CABIN DRY P 14 K VALUE PR2 Manage the K value for automatic program IRON DRY See explanation for P 13 P 15 HYST TEMP It controls the hysteresis TS 62 is preset on 10 C Means that when the working temperature is reached and the elements are turned off it will be a delay until the temperature has fallen to 10 C before the heating goes on again Shorter hysteresis in creases the energy consumption P 16 COOL DOWN After the heating phase the cabinet has a period of cool down to recondition the laundry and lower the temperature within the cabinet The time is set to 15 minutes Shorter time can give a better drying result but the energy consumption will also in crease PLEASE NOTE Without the cool down period the inner plates in the cabinet will be very hot when the user removes the laundry P 17 SHOW TEMP HU This parameter is for making it easier for service technicians to find out what is wrong If it is set in mode ON the cabinet will show current temperature and air humidity by respective sen sors When the automatic programs are on the parameter also shows information of humidity level when the drying process is stopped and when the cool down starts This information is shown in the display in the upper text fiel
6. d after about 1 minute drying P 18 SHOW LOGO Turns on and off the PODAB logo on the top of the LCD dis play P 19 SOUND This parameter controls if the sound shall be on or off In mode ON you can hear a distinct beep noise each time buttons to be chosen from are pressed or if a drying period is ended P 20 STANDBY In the mode ON the background light of the display is turned off automatically if no button is pressed for two minutes and no drying program is chosen The display light is turned on again when you push any button or the doors are opened In mode OFF the light is constantly off PODAB 2010 P 21 LIGHT TIME The lighting in the cabinet is turned on when you open the doors The parameter LIGHT TIME controls how long time the light is on if the doors are left opened When the time is ended the lamp is turned off automatically P 22 PAUSE TIME When the doors are opened during drying the drying program is paused If the doors are left opened for a longer time the cabinet will stop the program The time is adjustable from 0 30 minutes PLEASE NOTE If the parameter is set to 0 min ute the cabinet will stop the program as soon as the doors are opened P 23 COIN The cabinet TS 62 can be connected to a booking system To activate the function put the parameter in mode ON To start a program a connection over the control board s COIN contact is needed P 24 is
7. from the factory is 80 C P 7 DEF TEMP Sets the default temperature when the user goes to manual mode P 8 SHOW DEGREES In manual mode shows the chosen temperature in degrees for the three levels This function can be turned off so that only the symbol on the thermometer is shown P 9 MAX TIME Setting of time to choose in manual mode Maximum 9h 59 minutes P 10 DEF TIME This parameter controls the time which is default when the user goes into manual mode Standard is 40 minutes P 11 AUTOPROG When this parameter is set in mode OFF the automatic pro grams is inactivated If the user tries to go to automatic mode the display shows the text INACTIVATED P 12 14 is only displayed if P 11 is in mode ON P 12 TEMP AUTO PR Setting of the temperature to which the automatic program is working Preset to 80 C P 13 K VALUE PR1 TS 62 has a drying automatic function called HTS Humid ity Tracking System The cabinet dries the laundry to a certain humidity level When the humidity sensor measures that the humidity in the cabinet has reached a certain level the laundry is dry the cool down phase is activated The humidity level is adjusted to each new drying session and is not fixed The K value is part of the control function If the K value is increased the humidity level by which the cabi net stops for cool down will also increase A higher K value gives a shorter drying time as the
8. ng of them Service menu Activate the service menu To go to the service menu press both the left arrow buttons in about 5 seconds The LCD display shows SERVICE MENU Push the START button 5 times continuously to go in the pa rameter list Navigate in the service menu To browse in the parameter list use the two top buttons see picture eS i vAn A eC Ms O gt Change parameter values Depending on if the present parameter shows temperature time or ON OFF function the present value is shown on the left or the right hand side of the LCD To change the value use the arrow buttons Leave the service menu Push the start button PODAB 2010 Parameter list Parameter Alternative Factory position 1 LANGUAGE SWE ENG FRENCH ENG 2 PRESET OFF TS 62 T 196 TS 62 3 DEGREE UNIT C F c 4 MIN TEMP 25 gt MED 5 40 5 MED TEMP MIN 5 gt MAX 5 60 6 MAXTEMP MED 5 90 80 7 DEFTEMP MIN MED MAX MED 8 SHOW DEGREES ON OFF OFF 9 MAXTIME 1 00 09 59 02 00 10 DEFTIME 0 00 MAX TIME 00 40 11 AUTOPROG ON OFF ON 12 TEMP AUTO PR 25 90 80 13 K VALUE PR1 5 10 3 14 K VALUE PR2 35 50 40 15 HYST TEMP 0 20 10 16 COOL DOWN 0 00 0 20 00 15 17 SHOW TEMP HU ON OFF OFF 18 SHOW LOGO ON OFF ON 19 SOUND ON OFF ON 20 STANDBY ON OFF ON 21 LIGHT TIME
9. only shown if P 23 is set in mode ON P 24 SIGNAL TYPE This parameter is used when the cabinet is connected to a booking system Choose mode depending on which type of signal the booking system is sending PLS stands for pulse and means that the cabinet is booked per drying period One pulse gives one drying period N O is chosen when the signal is either on or off Usually the signal is set for a specific time during which the washing is booked for The current program will always be finished even if the signal is broken during the program P 25 WORK TIME The parameter shows total amount of hours the cabinet has been working Is also memorized if the electricity to the control board is broken P 26 TEST LOOP The testing program is started by changing the parameter val ues to ON The program can be used to control the compo nents in the cabinet Parts are activated as follows To jump to the next step press arrow button The program is automatically jumping over to the next level after 30 seconds Fans connected to FAN1 Fan connected to FAN2 also if you have an external fan Heating on All segments on LCD display are lit and the back ground light is flashing The temperature sensor shows current temperature 6 The humidity sensor shows current air humidity PO IN Ox P 27 CLEAR E CODE To be used to erase an e code in the display after it has been fixed Press button below YE