Home

EM3601-FX-SC Module User's Guide

image

Contents

1. a remote site Detailed information about configuring this module and advice about Fast Ethernet configuration rules can be found in the switch s user guide A Safety Warning Before installing or removing the EM3601 FX SC first disconnect the switch from the main power supply For full safety instructions please refer to the user guide that accompanies the switch A Warning Optical Safety for Fiber Optic Modules Under normal conditions the fiber optic transmit LED Light Emmitting Diode presents no hazard to your eyes CLASSI However we recommend that you do not directly view the fiber TX port or fiber cable ends when the unit is powered on Nor should you view the LED through a magnifying device when the unit is powered on Handling the Module Caution The EM3601 FX SC can easily be damaged by electrostatic discharge To prevent electrostatic damage observe the following guidelines Do not remove the EM3601 FX SC from its packaging until you are ready to install it Do not touch any of the module s pins connectors or components Hold the module only by its edges or front panel Wear an anti static wristband connected to a suitable earth ground whenever handling the module Store or transport these modules only in appropriate anti static packaging Installing the EM3601 FX SC 1 Ensure that the switch is disconnected from the main power supply and you are wearing an anti static wristband conn
2. CE Mark Declaration of Conformance for EMI and Safety EEC This is to certify that this product complies with ISO IEC Guide 22 and EN45014 It conforms to the following EMC specifications EN55022 1988 CISPR 22 1985 Class A EN60555 2 1995 Class A EN60555 3 IEC1000 4 2 1995 4kV CD 8kV AD IEC1000 4 3 1995 3V m IEC1000 4 4 1995 1kV power line 0 5kV signal line IEC 1000 4 6 1995 3Vrms This product complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC VCCI Class A Compliance Japan CORES HRRNRES SRS S Malis OV CCl OBE IEJ OS ZAWPRRNERTT CORB REE CHEATS Bik MBE FRITIEMHVET COMSICSPASOGHRE RT SLIBKINSCEMHIET Warranty Accton warrants to the original owner that the product delivered in this package will be free from defects in material and workmanship for a period of three 3 years from the date of purchase from Accton or it s Authorized reseller For the warranty to apply you must register your purchase by returning the registration card indicating the date of purchase and including proof of purchase There will be a minimal charge to replace consumable components such as fuses power transformers and mechanical cooling devices The warranty does not cover the product if it is damaged in the process of being installed Accton recommends that you have the company from whom you purchased this product install it THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WAR
3. RANTY WHETHER EXPRESS IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY FITNESS FORA PARTICULAR PURPOSE OR ANY WARRANTY ARISING OUT OF ANY PROPOSAL SPECIFICATION OR SAMPLE ACCTON SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ACCTON NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER LIABILITY Copyright Copyright 1999 by Accton Technology Corporation All rights reserved All trademarks or brand names mentioned herein are trademarks or registered trademarks of their respective companies Accton International Headquarters USA Headquarters No 1 Creation Road III 6 Hughes Science based Industrial Park Irvine CA 92618 Hsinchu 300 Taiwan R O C Phone Numbers Phone 886 3 5770 270 Sales 800 926 9288 FAX 886 3 5770 267 Support 888 398 4101 or 949 707 4847 Internet support accton com tw RMA 800 762 4968 EM3601 FX SC E0999 R01 150108 102 FAX 949 707 2460 Accton EM3601 FX SC Module User s Guide The EM3601 FX SC Slide in Module The EM3601 FX SC slide in module is designed for use in various Accton switch models At present suitable units include e CheetahSwitch Workgroup 3616 ES3616 Contact your distributor for advice on newly released switches which may be designed for use with these modules Caution Do not install this module in any other units The EM3601 FX SC includes 1 100BASE FX SC Type port which can be used to connect to
4. ected to a suitable earth ground Place the unit on a flat surface Using a flathead screwdriver remove the screws from the cover plate of an empty slot on the rear panel of the switch Keep the cover plate in a safe place If you remove the module replace the cover plate to prevent dust and debris from entering the unit and to maintain proper air flow Holding the module with the text on the front panel upright slide it into the unit ensuring that the edge connector is fully engaged Be sure the front panel of the module is flush against the switch and then attach it to the unit with the retainer screws attached to the face plate Making Fiber Optic Connections 1 Remove the cover from the fiber connector on the module Keep it in a safe place and place it back on the connector if you unplug the fiber cable from the module 2 Plug the fiber connector on the cable into the fiber optic socket on the module 3 Connect the other end of the cable to any device that has a standard 100BASE FX Fast Ethernet fiber interface Notes A fiber optic cable cannot exceed 2 km 1 24 miles at full duplex or 412 m 1351 ft at half duplex This maximum length may be less when connecting to a Fast Ethernet repeater Refer to the user s guide for the switch for more detailed information on cable length 4 Use the configuration method provided by your switch to match the communication mode of the attached device by setti
5. maximum Temperature 0 50 C 32 122 F Std Opr 40 70 C 40 158 F Storage Humidity 5 to 95 Non condensing Standards IEEE 802 3 IEEE 802 3u ISO IEC 8802 3 Certification CE Mark Emissions FCC Class A VCCI Class A CISPR Class A Immunity IEC 1000 4 2 3 4 6 EMI Certification FCC Class A USA This equipment has been tested with a Class A computing device and has been found to comply with part 15 of FCC Rules Operation in a residential area may cause unacceptable interference to radio and TV receptions requiring the operator to take whatever steps are necessary to correct the interference Class A Canada Department of Communications This digital apparatus does not exceed the Class Alimits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Department of Communications Cet appareil num rique respecte les limites de bruits radio lectriques applicables aux appareils num riques de Classe A prescrites dans la norme sur le mat riel brouilleur Appareils Num rques NMB 003 dict e par le minist re des Communications
6. ng the module to full or half duplex Putting the Switch Online 1 Power up the switch 2 Check the LED indicators on the switch to ensure that the module is operating correctly Refer to the switch s user guide for a description of the LED indications Troubleshooting If you experience any problems with the module check the following items before contacting your distributor Ensure the switch with the slide in module is powered up Ensure that the device attached to the module is powered up and operating correctly Ensure that the module is properly seated in the slot Verify that the ports are configured to match the communication mode used by the attached device full or half duplex Check all connectors on both ends of the cables to be sure they are properly engaged When inserting fiber cable into an SC type port be sure the plug clicks into place to ensure that it is properly seated e If you are using an SC ST converter try switching the TX and RX connections e Clean the cable plugs by wiping them gently with a clean tissue or cotton ball moistened with a little ethanol Dirty fiber terminators on the fiber optic cables will impair the quality of the light transmitted through the cable Specifications Ports 1 100BASE FX SC type Cable Type 50 125um 62 5 125um MMF Switching Method Store and forward Filtering Forwarding Full line speed Queue Buffer 256K bytes per port Power Compumption 3W

Download Pdf Manuals

image

Related Search

Related Contents

BPMN-‐Q installation manual  BdA frc150 dt+engl A6 5km RZ.FH10  User Manual  SECTION PAGE  teléfono celular zmcK885 manual de usuario en español  Mount heavy equipment in tight spaces.  Troubleshooting and maintaining Cisco IP networks (TSHOOT    Válvulas mezcladoras AllTemp™  Philips LED Bulb 8718291192947  