1. with utility power 3 Hi level battery charger to prolong battery s life and fully charge the battery 4 With actual overload protection both in line and battery mode 1 1 Front and rear view 1 1 Power Switch 1 2 USB Port option 1 3 Phone Jack option 1 4 AC Input 1 5 UPS Outlets 1 6 AC Fuse Breaker 1 7 Convenience Outlet For models of FS600 2 Installation 2 1 Inspection Inspect the UPS upon receipt The packaging is recyclable save it for reuse or dispose of it properly 2 2 Utility Power The input power cord on the rear panel needs to plug into a socket on the wall Please notice the voltage of utility power should match with the UPS For example the UPS is 220V the input utility power should be 220V as well 2 3 Connection The employed equipment s power cords such as computer are plugged into the sockets on the rear panel 3 Operation 3 1 Switch on When utility input is connected to the UPS press power button and keep pressing until the buzzer sound stop After that connect the electrical cords of the equipments that will be used such as desktop computer and LCD monitor to the rear panel of UPS ATTENTION At backup mode UPS can be automatically turned off if none of the connected loads is operating Green mode No Load shut down function CAUTION Never connect a laser printer or plotter to the UPS with other computer equipment A laser printer or plotter period
2. working under overload condition the connected loads exceed the maximum rated capacity the UPS will emit continuous alarm to warn an overload condition In order to protect the unit and the loads the UPS will be automatically turn off Please disconnect nonessential devices from UPS to eliminate the overload alarm 5 Software and Interface Port Option 5 1 Power Monitoring Software The OPTI SAFE Sentinel software or the other power monitoring software is applied standard RS 232 or USB interface to perform monitoring functions It certainly provides graceful shutdown of computer in the event of power failure Moreover it simultaneously monitors the UPS and displays all the diagnostic symptoms on the monitor such as voltage frequency and battery level and so on For UPS with RS 232 communication port the software is compatible with Windows 95 NT4 0 98 ME 2000 XP 2003 Server Novell Netware Linux and others For UPS with USB communication port the software is compatible with Windows 98SE ME 2000 XP 2003 Server Call your dealer for more information about the solutions of others operating system 5 2 Interface Kits A series of interface kits is available for operation systems that provide UPS monitoring Each interface kit includes the special interface cable required to convert status signals from the UPS into signals which individual operating system recognizes The interface cable at UPS side must be connected to REMOTE PO
3. MAS5 15R 1x0V IEC320 female appliance coupler 2x0V Battery Back Up Slow beeping sound about 0 47Hz Alarm Battery Low Rapid beeping sound about 1 824Hz Continuously beeping sound Ambient 3 500 meters max elevation 0 95 humidity non condensing Operation 0 40 C Environment Audible Noise lt 40dBA 1 meter from surface Storage Condition 15 000 meters max
4. RT at computer side can be either series port or USB port The other installation instructions and powerful features please refer to READ ME file 5 3 The characteristics of computer interface port The computer interface port has the following characteristics The communication port on the back of the UPS may be connected to host computer This port allows the computer to monitor the status of the UPS and control the operation of the UPS in some cases Its major functions normally include some or all of the following To pop up a warning message when power fails To back up opened files before operating system shutdown To turn off the UPS Some computers are equipped with a special connector to link with the communication port In addition special plug in cord may be needed Some computers may need special UPS monitoring software Contact your dealer for the details on the various interface Kits ATTENTION Sentinel software and interface port function just available for model name with P affix The standard RS 232 cable or USB depend on communication port on UPS can be connected between UPS REMOTE PORT and computer COM port for the Sentinels software Appendix A Troubleshooting push time too short second UPS can not tur on LED notlignt Load less than 30W at battery Normal condition No load shutdown mode function is active See 3 2 Plug in the power cord AC fuse burn out Replace the AC fuse UPS alway
5. User Guide Fighter Series Model 600 600B Important Safety Instructions IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries The unit is intended for installation in a controlled environment Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing battery replace with the same number and type CAUTION Do not dispose of battery or batteries in a fire the battery may explode CAUTION Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles Wear rubber gloves and boots Do not lay tools or metal parts on top of batteries Disconnect charging source prior to connecting or disconnecting battery terminals LELIKE al cal t IMPORTANT SAFETY INSTRUCTIONS 2 00ceeeseeeeeeeseeeeeeeseeeseseseeeeesesnenseseeeenens 1 TABLECOR CONTENTS amaren aerae naaie aaae anaa Aaaa aaa aia aa a a Aaaa aaa 2 INTRODUCTION wocvvssatsces
6. ically draws significantly more power than when its idle status and may overload the UPS 3 2 Switch off Press the power switch and keep pressing more than 3 seconds to turn off the UPS when UPS is in line or backup mode 3 3 Silence When UPS is under BACKUP mode press power switch more than 1 second to silence the audible alarm The function is disable when UPS is under condition of LOW BATTERY or OVERLOAD 3 4 Self test function Press power switch while utility power is connected UPS will perform self test procedure automatically 4 1 BACKUP slow alarm When the UPS is working under BACKUP mode the UPS would emit audible alarm The alarm stops when the UPS is return to LINE mode operation ATTENTION The alarm of BACKUP is going to beep every 2 seconds Slow speed beep ATTENTION The UPS provides mute function for the warning When the beeping sound occurs press ON to stop it and press ON again to regain the sound 4 2 LOW BATTERY rapid alarm In the BACKUP mode when the energy of battery becomes to lower level about 20 30 The UPS beeps rapidly until the UPS shuts down from battery exhaustion or returns to LINE mode operation ATTENTION The alarm of the batteries caused by low voltage beeps every 0 5 second ATTENTION The rapid alarm under LOW BATTERY condition cannot be muted 4 3 OVER LOAD continuous alarm When the UPS is
7. s at battery P Line voltage too high too low J mode Normal condition or black out PCB failure Call for service Battery is not fully charged Recharge the UPS at least 6 hours Back up time too short y y g 9 PCB failure Replace PCB call for service Buzzer continuous Overload Remove some loads beeping Appendix B Specifications Capacity 600VA 300W 100V 110V 20 120V 20 15 220V 230V 240V 166V 280V at line input Frequency 50 or 60Hz 10 auto sensing Voltage Backup Simulated sine wave at 100V 110V 115V 120V 220V 230V mode 240V 5 FS600 only 220V 240V Output Frequency Backup Mode Transfer Time 4 milliseconds Typical Spike Protection 460 Joules 2ms Unit Input Fuse or circuit breaker for overload amp short circuit protection Input Voltage 50 or 60Hz 1Hz Overload UPS automatic power off if overload exceeds 110 of nominal Protection s and Filtering Protection at 10s and 130 at 3s 10 Base T Cable Port Short Circuit UPS output cut off immediately or input fuse protection Sealed maintenance free lead acid batteries with 3 6 years typical lifetime NO YES Type Spe 6 hours to 90 of full capacity Batter J Auto discharge protection Back up Time PC with 17 LCD 10 min monitor Net ES Kg Physical Dimension mm 90 x 254 x 126 90 x 254 x 146 WxDxH 3 5 x 10 x 5 3 5 x 10 x 5 7 Input Inlet IEC 320 power inlet NE
8. vestewceviaccwtvesuncee a E EAA EE 2 Le PRESENTATION iscccscccnnesceedesentescute ince cesdeboceuesbdeedennbesduuitusnceteccreetues daa aaa 2 2 INSTALLATION sssrinin a aaa 4 Bi OPERATION visicaseeeasicesiied E aAA R A E 4 A ALARM eaan a E e A A EE EE 5 5 SOFTWARE AND INTERFACE PORT OPTION s secceeseeeeeeenseeeeeenseeneeenees 5 APPENDIX A TROUBLESHOOTING ccessesceeeseeeceenseaeeeenseaeeeenseaeeeenseaeeeensenenennes 6 APPENDIX B SPECIFICATIONS sssececssscesseeenseeeenseeeceeenseanenseeeenseeeseansensanenseaenes 7 Introduction Please read and save this manual Thank you for selecting this uninterruptible power system UPS It provides you with a perfect protection for connected equipment The manual is a guide to install and use the UPS It includes important safety instructions for operation and correct installation of the UPS If you should have any problems with the UPS please refer to this manual before calling customer service 1 Presentation The UPS is a OFF line uninterruptible power system UPS When utility input is normal the UPS provides surge protection and energy to charge the internal battery If the utility input is abnormal the UPS can supply AC power to the load immediately 1 Utilizes microprocessor based controls it will minimizes the dependency on hardware Beside this it maximizes system flexibility and optimizes the assurance of reliability 2 Automatic frequency selection to match

Download Pdf Manuals

image

Related Search

Related Contents

光リモコン解読器 AO−2600A 取扱説明書  AXIS 262+ Installation Guide  Guide du tri sélectif - La Communauté de Communes du Pays de  Tripp Lite WEXT3-SU10K  Z1 PLUS IP65 DMX-512 LED CONTROLLER User Manual Rel 2.0  Débitmètres électromagnétiques Rosemount série 8700  Manual del Usuario - Gervasoni Ingeniería SRL  Little Disk 2.5 USB N Datasheet  Mark-it.com User Guide  USER MANUAL  