Home
Visio-PCR120_MFR120 USER MANUAL.vsd
Contents
1. Operate Keypad Chain Sling Hole RFID Card Scan Area 9 1 Battery Box L OPEN RFID Card Scan Area Scan the RFID card to reader 9 Operation LED Indicator When encountering erroneous input defective card misread bad memory or incorrectly encoded data and so on the device will turn on the ERROR indicator LCD Main Screen Indicating the device is ready for use low battery in operational mode Connector For connection to host computer and external Power Battery Box Put the battery in box and hold battery Operate Keypad Turn the PCR120 MFR120 on off power and Operate Chain Sling Hole Connect to chain sling Technical And Operational Description LCD Display Status Function Area Main Display Area Keypad Guidance Area Status Function Area 1 Power Status 5 Decode Status Battery Power Supply Card Decoded Low Battery Power Supply IK Mifare IK Card Decoded a External Power Supply AK Mifare 4K Card Decoded DS Mifare DESFire Card Decoded 2 Scan Status UT Mifare Ultralight Card Decoded N Scaning FL Felica Card Decoded 3 Buzzer Status 6 Guidance Number Buzzer ON XXXXXX Current Record Number When Scanning or Vi
2. DSUB 9P POWER DSUB FEIVALE PIN DSUBSPFEMAEPN FUNCTION WC PLA 2 O _ ___ Connect to PC RS 232 PORT oh Personal Computer External power DC 5V Note 1 When PCR120 MFR120 is connected disconnected with an external power adapter it would be turned On Off automatically 2 When PCR120 MFR120 is not connected with an external power adaptor the corresponding key for power on PCR120 MFR120 needs to be pressed all the time during the communications with the PC 13 Connections WAS 1571 USB interface cable Connect to PC USB SE E y PCR12
3. Date Year 4 Calendar Default Month Date Year Set Date Year Month Date Set Time 4 2 Set Date Time Week Hour Minute Second 5 Information 5 1 Product Name Product Description Firmware Version Technical and Operational Description B Display Information Exceptional Indication Check RTC The 15 malfunctioning After scan card set Date and Time The record already is full Download Records FLASH Full After scan card and Erase Records The record can t write into the FLASH memory Check FLASH Contect Agent Scan Card can t decode Scah Card again Decode Error After scan card or Change Card No Record in FLASH memory No Record Enter Database View function Swipe Card The FLASH memory not empty Download Records Enter Calendar function and Erase Records ISP MODE Enter PMM de Update New Firmware By communication command LED Indicator Status Green LED Red LED Read Card Take turns blink Auto Power Off pun Beep Beep 2 times Record not empty Read OK Off Beep 1 time Blink Read Error Off 1 time Beep Beep Beep Firmware Management Mode Off x 10 Technical and Operational Description Operational Description 1 Powered by Battery For normal use the unit is powered by battery Push the Power Switch Button for about 2 seconds to turn on the unit Also
4. 20 4 1 ABCDEFGHI ay Database is empty 20 Communication Protocol ERASE ALL RECORD STX E CR Erase Duration lt 60 seconds T or sx R STX Database is recovery O zb 2 TC si i I nvalid command 21 Communication Protocol GET PRODUCT VERSION sx F A Row No T VERSION ROM ROM Txxxx xxxx Rom serial number Vx xxRm Vx xx Firmware version x xx Rm Modify m times VERSI ON STX ROM serial number ROM TO571 Firmware version 1 03 Modify times 0 SET DATE AND TIME YYYYMMDDhhmmssw STX YYYY Year 2000 20xx MM Month 01 12 DD Date 01 31 hh Hour 00 23 mm Minute 00 59 SS Second 00 59 Ww Week 0 6 EXAMPLE Set Date 2000 5 6 Set Time 12 30 00 Saturday Invalid Date Time Set Date Time is not executed 22 Communication Protocol GET DATE AND TIME STX STX Get Date 2000 5 6 Get Time 12 30 00 Saturday sm J 9 55 T STX Set Machine ID is not executed 23 Communication Protocol GET MACHINE Get Identification is not set or otherwise invalid ENTER FIRMWARE MANAGEMENT MODE Enter firmware management mode 24 Communication Protocol SET REGI STER REGISTER PARAM CHKSUM PARAM Set P
5. manual may cause harmful interference to radio communication Operation of this equipment in a residential area 1s likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Information PCR120 Series 125KHz RFID Reader MACHINE TYPE FUNCTION ce E 65 232 8192 PCRI20 RS232 Interface e x USB Ver 1 1 8192 PCR120U USB Interface Read the instructions on your device before installing batteries Insert batteries into your device properly with the and terminals aligned correctly Discharged batteries should be removed from equipment to prevent possible damage Store the batteries in a cool and dry place Batteries should be stored at temperatures between 50 10 C and 77 25 with relative humidity not exceeding 65 percent Refrigeration of alkaline batteries 15 not necessary because of their very good capacity retention Excessive temperature cycling and storage at temperatures greater than 77 F 25 should be avoided to maximize shelf life Remove batteries from the electrical device if the device 15 not going to be used for a long time Keep battery contact surfaces and battery compartment contacts clean by rubbing them with a clean pencil eraser or a rough cloth each time you replace batteries Keep batteries away from children If swallowed contact a physician at once Don
6. push the Power Switch Button for about 2 seconds to turn off the unit at Switch Mode After the unit is turned on the power would be turned off automatically if there is no scanning a card on the unit in 30 seconds default at Auto Power Off Mode This means the unit would be turned off if no scanning a card again in every 30 seconds default after every card scanning It would have Low Battery Detect Warning indication when the unit is powered by battery 2 Powered by Cable When PCR120 MFR120 is connected disconnected to external power adapter by the WAS T0017 RS232 cable or USB port by the WAS 1571 USB cable it would be turned On Off automatically When the unit is connected with the PC through the communication Cable 5 0017 WAS 1571 and the PC is running 20 120 software and the unit is turned on Then you can do the unit Setting Configuration or data downloading When the device is powered by cable from PC the Power Switch would have no function and the unit would have no Low Battery Detect Warning function 3 Real Time Clock Setting Before start using the unit you must set the Real Time Clock RTC inside the unit to your local time If there 15 battery for quite a while or it is powered by cable for quite a while this would cause Real Time clock RTC malfunctioned due to no power supply When put on the battery to turn on the unit and the Red Green LED take turns to blinks this means
7. t recharge a battery unless it 15 specifically marked rechargeable Attempts to recharge an alkaline battery may cause an imbalance within the cell leading to gassing and possibly explosion on either charge or discharge cycles Don t dispose of batteries in a fire they may rupture or leak Don t carry loose batteries 1 a pocket or purse with metal objects like coins paper clips etc This will short circuit the battery generating high heat Information B MFR120 Series 13 56MHz RFID Reader MFR120 RS232 Interface e USB Ver 1 1 8192 MFR120U USB Interface Read the instructions on your device before installing batteries Insert batteries into your device properly with the and terminals aligned correctly 2 Discharged batteries should be removed from equipment to prevent possible damage 3 Store the batteries in cool and dry place Batteries should be stored at temperatures between 50 F 10 and 77 25 C with relative humidity not exceeding 65 percent Refrigeration of alkaline batteries is not necessary because of their very good capacity retention Excessive temperature cycling and storage at temperatures greater than 77 25 C should be avoided to maximize shelf life 4 Remove batteries from the electrical device if the device 15 not going to be used for a long time 5 Keep battery contact surfaces and battery compartment contacts clean by rubbing them
8. with a clean pencil eraser or a rough cloth each time you replace batteries 6 Keep batteries away from children If swallowed contact a physician at once 7 Don t recharge a battery unless it is specifically marked rechargeable Attempts to recharge an alkaline battery may cause an imbalance within the cell leading to gassing and possibly explosion on either charge or discharge cycles 8 Don t dispose of batteries in a fire they may rupture or leak 9 Don t carry loose batteries in a pocket or purse with metal objects like coins paper clips etc This will short circuit the battery generating high heat Information Standard Package Main unit PCR120 MFR120 x J NN i aS Se Yeas YV RS232 Cable for PCR120 MFR120 series WAS T0017 se LRO3 AAA ALKALINE 1 5V Battery BAT T0010 Chain Sling TMO9F1001 USB Cable for PCR120U MFR120U series WAS 1571 Technical and Operational Description Front Panel and Operations LCD Main Screen Operation LED Indicator f TAE A Cy Connector e 17
9. 0 MFR120 Personal Computer Note 1 When PCR120 MFR120 is connected disconnected with USB port it would be turned On Off automatically 14 Card Data Format CARD DATA STRING p gt DATE amp TIME DATE TME SP Cwwwwwoo WWwwss SP W _ WWwwss SP W SP W 1 Date have 3 formats YYYY MM DD MM DD YYYY DD MM YYYY 2 SP is the SPACE characters 20h 3 TIME is 24hrs WEEK amp CARD TYPE WEEK CARD TYPE SUN 0 Mifare 1k 1 MON 1 Mifare 4k 2 TUE 2 Mifare Ultrlight 3 WED 3 Mifare DESFire 4 THU 4 EM 125K 5 FRI 5 Felica 6 SAT 6 EVENT EVENT CODE EVENT 0 1 2 3 4 USER DEFINE 5 EVENT 6 7 8 9 5 g 29 e a NM 4 8 Ea Specifications 125KHz RFID Card for PCR120 EM compatible64 bits ASK Manchester coding Reading distance 10 50mm depends on 13 56MHz RFID Card for MFR120 Compatible ISO 14443A ISO 18092 Reading distance 10 40mm depends on card RS232 Interface RS232 Half Duplex 8N1 19200 bps USB Interface Full compliance with the USB Specification V 1 1 The device uses a Virtual Serial Port Driver making it appear to have the software like a standard RS232 Serial Port LCD Display LCD type FSTN Dot arrangement 101 x 67 Dots M
10. PCR 120IMFR120 Series RFID Card Reader with LCD User s Manual Manual Part Number TM951183 Rev 02 JAN 2008 REGISTERED TO ISO 9001 2000 8F No 31 Lane 169 Kang Ning St Hsi Chih Taipei Hsien 221 Taiwan hone 886 2 2695 4214 FAX 886 2 2695 4213 www gigatms com tw Copyrighto GIGA TMS INC Printed in Taiwan Information in this document is subject to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of GIGA TMS INC REVISIONS March 07 Initial Release JAN 08 Add RFID Scan Time Register Contents incite EM DRM RR NEL E ADI NEM 4 Technical and Operational Description entrent 7 Connectiole ananena 13 Card Data Format 15 Specifications 16 Communication Protocol e e ee eo eo eo eee rero o eoe e ee ee ee e 17 FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment 1s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction
11. arameters of Register CHKSUM REGISTER PARAM GET REGISTER Sx REGSTER CR REGISTER Register Address 2 Bytes Width 00h FFh PARAM Set Parameters of Register REGI STER TABLE Register Function Description 10h Auto Off Duration Low byte 00 FFh 0 255 second 11 Auto Off Duration High byte OOh Auto Power Off 12h Power Mode FFh Switch 13 14h i 15h RTC cal value 00 FFh 16h n 17h 18h Back Light Duration OO FFh 0 255 second OOh Off 19h Buzzer On 00h mm dd yyyy LAh Date Format yyyy mm dd other dd mm yyyy 1Bh Display Mode ID Number 1 m O5 FEh 5 254 second 1Dh RFID scan time FFh 10 second 0 1 only 0 event 2h 0 1 event Option of event nh O n 1 event n 10 10 FFh 0 9 event OOh continuous Mode scan Mode other Button Mode 20 2Fh User Name 16 Characters 30 1FBh lFC 1FFh Password 4 Characters 23
12. atrix LCD Module Viewing direction 6 O clock Communication Protocol Version 1 2 GNET V1 2 CLOCK Real Time Clock RTC module and back up capacitor Memory Size for Storing Data CMOS Serial Flash Memory 512K bytes Up to 8192 records 32 Bytes Record Battery Power Single cell alkaline nickel cadmium NiCd or nickel metal hydride NiMH battery Power Supply from Cable DC 5V 200mA for RS 232 or USB Powered Dimensions 58x W 20x HA7 mm Environment Operating Temp 0 55 Storage Temp 10 60 C Humidity 10 90 relative Mounting Portable or Any surface 16 Communication Protocol Handshaking NACK NACK TIME OUT TIME OUT LT TX1 TX2 TX3 TX3 TX4 PACKET STX CONTENTS CR TX CR 5 REPLY CONTENTS Dec Hex Control Key Function STX CONTENTS CHKSUM 13 od M cemageReun REPLY 17 Communication Protocol 20 120 Terminal has an extensive list of Commands that allow manipulating its internal database setting functional parameters and getting data on its current status There are 2 levels of access to the PCR120 MFR120 User and Supervisor Supervisor level is protected by a Password Sensitive data can be downloaded or altered only on the Supervisor level General Terminal data is available on the User level as well Command I nd
13. ewing Database 4 Event Status x Main Menu Item When Operating Menu 1 9 Event X X Sub Menu Item When Operating Submenu Main Display Area Display Date amp Week amp Time Menu Item Record Data Parameter Setting Other Information Keypad Guidance Area 1 Corresponding Key Power Exit Back Cancel No Key Function 2 Corresponding Key Up Up scroll Decrease Scan Key Function ing Key 3 Corresponding Key Menu Enter Save Next Yes Key Function 8 Technical And Operational Description Function Menu Display Machine ID 1 1 Machine ID 2 Characters Default 00 Display User Name 1 2 User Name 16 Characters Max Display Mode 1 Profiles Epp ID Number Set View Mode 1 4 View Mode Big or Small Default Big Set Scan Mode Button or Continuous Default Button Set Back Light Duration 03 255 Seconds Default 15 Seconds Set Auto Power Off Duration 2 2 Auto Power Off 03 255 Seconds Default 30 Seconds Set Power Mode Switch Mode or Auto Power Off Mode Default Switch Mode Set Operate Sound Default ON Reset Default BackLight 15 seconds 2 5 Reset Auto Power Off 30 seconds Power Mode Switch Mode Sound ON Display Memory Status oaks pauls Used Space Unused Space Total Space 3 Database Display all records in memory Set Date Format Select Year Month Date 4 1 Date Format Date Month Year Month
14. ex Table Topic Command Contents Description Access Security Command u L Characters for Login 0000 access New four characters Set Password password Database Commands Number of Record 5 Number Read Record by Number DATABASE S E _ EraseAll Record S R Rollback Record 5 M J All Record General Commands UJ Get Product Version 5 5 Date Time Week 5 Date Time and Week UJ T 4 JJ JGeteeandTim 5 J X J JjeMehielD et Machine ID UJ X S Enter Firmware Management Mode S B eet Register PS J Jg St register Reply Index Table Reply Contents Reply Information Checksum Error Command Execution Failed Database is Empty Invalid Command or Data Communication Protocol Access Security Commands LOGIN for Supervisor Access Level STX PASSWORD STX PASSWORD 4 Characters for Login 0000 Initial value Invalid password LOGOUT SET PASSWORD TSX PASSWORD PASSWORD New four characters password Communication Protocol EXAMPLE GET NUMBER OF RECORD NUMBERD Record Count 4 Bytes Width 0000h 0800h 04 six Je oR SIXT A DATE SP_ WEEK EVENT CR SIXT ForDorF Foz A 20070531 103923
15. r 9 Firmware Management Mode FMM FMM allows you to quickly upgrade your PCR120 MFR120 internal firmware via com port and also check validity of currently loaded firmware Contact your dealer for most recent firmware upgrade files 10 Database in memory The PCR120 MFR120 allows you to manage database by software The Logical Erase Database will logically clean the database The Recovery Database will recover the previous erase and not yet covered database The record pointer will return to the top of the database after any erase 11 Technical and Operational Description Replace Battery Note 1 Read the instructions on your device before replace new battery 2 PCR120 MFR120 can used Single cell alkaline nickel cadmium NiCd or nickel metal hydride NiMH Battery 1 Power turn off 4 Take new battery OPEN 3 Take the battery away 6 Fix the battery cover 12 WAS T0017 RS232 interface cable
16. the RTC 15 malfunctioning and you must do the RTC time setting before you use the unit 4 Low Battery Detect When the device is powered by battery it would have Low Battery Detect function When the battery goes low the LCD would display __ and you must change battery immediately otherwise the unit would shut down any time without pre warning 5 Scan RFID Card When PCR120 MFR120 is showing the status of any function on the screen after presenting a RFID card to PCR120 120 reader 20 120 15 displaying card ID and record s information on the screen immediately When 120 120 is not working for next card scan PCR120 MFR120 reader will back to default screen automatically 6 Operate for Calendar Before setting calendar function please delete remaining records from PCR120 MFR120 reader if there are records in the memory of PCR120 MFR120 your operate setting for Calendar PCR120 MFR120 reader will display Record no empty on the screen 7 Memory Full Warning Log database memory is full You are not able to add any new records Free the log database memory by uploading the data to the PC 8 Communication by WAS T0017 RS232 cable You must use external power when the PC connect to PCR120 MFR120 by WAS T0017 RS232 cable or else the communication is not action You should press key PCR120 MFR120 until the communication is finished if you don t use external powe
Download Pdf Manuals
Related Search
Related Contents
GALVANIC BODY SPA Zanussi ZEE6140FXA hob Bella Morocco - Embroidery Online User Manual - Grandbeing User Manual Manual de instalación y mantenimiento Módulo de entrada Leaflet SC1991_00 Released Portugal (Portuguese) High DVC-250IP Hoja Informativa 4 México, D.F., a 20 de Enero de 2014 Copyright © All rights reserved.