1. Cancel Figure 5 43 Consistency Check Status Box The Consistency Check Status box Figure 5 43 displays the progress of a logical drive consistency check Click Cancel to stop the consistency check You may need to check the Views menu to see if Consistency Check Status is still enabled If so you may need to cancel other consistency checks as well Click Close to close the Consistency Check Status box at any time 5 46 GAM Client v2 30 and WSAM User s Manual Monitoring Expand Capacity Status If an expand array also called expand capacity process is currently underway open the Expand Capacity Status box as shown in Figure 5 44 to monitor the progress of this process Expand Capac Figure 5 44 Select Expand Capacity Status Expand Capacity Status Controller 2 Figure 5 45 Expand Capacity Status Box The Expand Capacity Status box Figure 5 45 displays the progress of a disk array capacity expansion WARNING You should not attempt to cancel an Expand Array Expand Capacity process data loss will result Click Close to close the Expand Capacity Status box at any time Manual No 771961 5 47 Battery Backup Unit Monitoring and Maintenance Battery Backup Unit Monitoring and Maintenance If your controller is equipped with an Intelligent Battery Backup Unit BBU you will be able to open the BBU dialog box as shown in Figure 5 46 Sign On Define Serve
2. Manual No 771961 G 3 Glossary External RAID Operation External RAID Controllers use their host ports to connect to one or more Host Bus Adapters in one or more host computer systems Depending on the model and configuration of the controller there may be from one to four host ports Each configured logical drive consumes a particular bus target ID LUN on the host system Multiple sets of disk drives are connected to the controller via its drive channels There may be as many as six drive channels depending on the controller model and configuration In duplex or Active Active mode two identical External RAID Controllers are connected to the same hosts via their host ports to the same drives via their drive channels and to each other via a special hardware link for heartbeat sensing This forms a redundant controller system The two controllers work together handling data traffic and mirror their write data in each other s cache memory If one of the controllers fails or otherwise becomes non operational the surviving controller takes over its responsibilities with no loss of data External RAID Controller The controller acts as a bridge between host channels and drive channels and implements the RAID function On the drive channels the controller acts as an initiator The host channel ports are implemented as target IDs with logical drives presented as LUNs under the target IDs Host to LUN Mapping The host to LUN ma
3. Intelligent BBU Scan Devices Advanced Functions Settings Figure 5 19 Select Enclosure Information The Enclosure Information dialog box is displayed with the Information page active Enclosure Information x Information Details Enclosure Status Type WWN ING OCritical SES 5757 4e 2d 2d 2d2d31 MYLEX DACS6OFF V1 1 12 MM i Failed SAF TE 57574e2d2d2d2d32 MYLEX DACQBOFF 22 12 2 Critical SES 2d 2d 2d 2d 2d 2d 2d 2d WW WWW WwW 12 Figure 5 20 SES Enclosure Information Information Page Manual No 771961 5 21 Enclosure Monitoring and Management Information Page Enclosure Information Figure 5 20 displays the following about the currently available Fibre enclosures The status of each enclosure identified by an icon and an enclosure number 1 32 as well as one of the following expressed in text e OK All components are optimal e Critical Some component has failed one more failure may result in data loss e Failed A failure has occurred that may result in data loss The enclosure type SES SAF TE The World Wide Name or Inquiry WWN INQ for the enclosure e For SES The World Wide Name as 8 hex bytes e For SAF TE The first 8 bytes of the Inquiry command s data The vendor identification The product identification The product revision level The number of drive slots in the enclosure cabinet 5 22 1 An undetermined enclosure shows as a question m
4. 389 393 399 Error Codes Misc error found Temperature is above 50 degrees Celsius StorageWorks enclosure reported critical state Internal log structures getting full PLEASE SHUTDOWN AND RESET THE SYSTEM IN THE NEAR FUTURE Controller has been reset Battery Power Low Controller s partner is gone controller is in failover mode now Information Level 4 oOo N NN NY 128 129 130 A hard disk in array changed status A hard disk been added as hot spare An automatic rebuild has started A manual rebuild has started Rebuild is over Rebuild is cancelled A new physical device has been found A physical device has been removed A previously configured device is now available Expand Capacity Started Expand Capacity Completed SCSI command timeout on physical device SCSI command abort on physical device SCSI command retried on physical device SCSI device reset Request Sense Data available A Consistency check is started Consistency check is finished Consistency check is cancelled Manual No 771961 A 3 Information Level 4 133 136 137 138 139 140 144 145 146 148 149 150 151 153 154 155 257 259 273 275 290 292 306 384 390 392 394 396 397 A 4 No Message A logical drive has been placed online An automatic rebuild has started on logical drive A manual rebuild has started on logical drive Rebuild on logical drive is over Rebuild on logical drive is c
5. Define Server Groups Select Current Server Group Ctri G Select Current Controller Ctrl C Raid Assist Initialize Logical Drives Controller Information Enclosure Information Controller Options Intelligent BBU Scan Devices Advanced Functions Settings Figure 4 3 Select Define Server Groups Define Server Groups 71 x Server Groups Servers 192 192 1921 Add Remove Cancel Figure 4 4 Define Server Groups Dialog Box In the Define Server Groups dialog box Figure 4 4 do the following 1 Click the Add button under the Server Groups section of the dialog box 2 Inthe Adding Item dialog box enter a name for the server group that you are adding 4 4 GAM Client v2 30 and WSAM User s Manual Configuration 3 Click OK The Define Server Groups dialog box will reappear with the newly defined server group added Adding a Server to the Servers List With the Define Server Groups dialog box open Figure 4 4 do the following 1 Click the Add button under the Servers section of the dialog box 2 In the Adding Item dialog box enter the IP address of the server that you are adding If you re running GAM Client under Windows NT you may instead enter the name of the server 3 Click OK The Define Server Groups dialog box will reappear with the newly defined server added 4 To add more servers to the gr
6. Welcome Dialog Box In the RAID Assist Welcome dialog box Figure 4 29 do one of the following e Click the Automatic Configuration button if you want to provide only minimal input and allow RAID Assist to set up an optimal configuration automatically or e Click the Assisted Configuration button if you want RAID Assist to lead you step by step through the configuration or e Click the Manual Configuration button if you want full control over your configuration setup or e Click Cancel if you want to exit RAID Assist without any changes 4 34 GAM Client v2 30 and WSAM User s Manual Configuration Automatic Configuration Automatic Configuration provides three options e New Configuration Sets up a new configuration on the controller deleting the previous configuration and data if any e Add Logical Drive Sets up additional arrays logical drives leaving the existing array s intact At least one array must be configured on this controller and unconfigured drive space must remain e Expand Array Restripes data in your array across additional unconfigured drives to expand the capacity of the array Open New Configuration for example as shown in Figure 4 30 Automatic Configuration 2 x m Data Overwrite Method Create a new configuration If there is an existing configuration it New Configuration will be overwritten and all data will be lost m Data Retain Method Utilize the remai
7. When you open Statistics View the Settings page is displayed Here you will define the controllers channels and target physical devices or logical drives to include for statistical analysis You select an operation to analyze define a color and line segment to differentiate this analysis from others used for comparison and optionally save your settings and capture data to a file Figure 5 23 shows the Settings page Statistics 204 32 130 200 x Settings Line Graph Pie Graph Bar Graph m Device Selection el Device type Controller Physical C Logical 1 DAC960PD Operation Reas Color COC Ccm TaT E OjO ns E Lee Add To Delete Delete All Sample Period fi sec Display Data Capture Data Save Settings Open Settings Close Device CO Chn Tatl Tat2 T at a Figure 5 23 Statistics View Settings You build a string which defines a line of data on a line graph a section of a pie graph or a bar on a bar graph Each string consists of one or more controllers channels and physical devices or logical drives to include in the analysis an operation to be analyzed and a color and line style for line graphs to represent this string graphically To build an analysis string 1 In Device type select either physical devices or logical drives for the analysis string you re building Manual No 771961 5 27 Performance Moni
8. 3 aan ia o CHOChn Tat0 Tatt CommandFinis Read Add To Delete Delete All Display Data Capture Data Save Settings Open Settings Close Figure 5 32 Performance Analysis Settings You build a string which defines a line of data on a line graph a section of a pie graph or a bar on a bar graph Each string consists of one or more controllers channels and physical devices or logical drives to include in the analysis an item and operation to be analyzed and a color and line style for line graphs to represent this string graphically To build an analysis string 1 In Device type select either physical devices or logical drives for the analysis string you re building In Device Selection do the following 2 Select one or more controllers to include in the analysis string Click All for all controllers For individual controllers make sure All is not highlighted 3 Select one or more channels to include in the analysis string Click All for all channels For individual channels make sure All is not Manual No 771961 5 37 Performance Monitoring highlighted If you chose Physical under Device type select one or more targets to include in the analysis string Click All for all targets For individual targets make sure All is not highlighted If you chose Logical under Device type select one or more logical drives to include in the analysis string Click All for a
9. Mylex External RAID Controllers Figure 5 11 shows the Controller Information window for an External RAID Controller Controller 0 Information Model Firmware Version Cache Size Intelligent BBU Host Ports Drive Channels Bus Type Bus Width Bus Speed Physical Devices Logical Drives r Host Connection Information OS Controller 2 DACSB6OFF 599 10 32MB DRAM No mre ae gt FC AL cal 100 MB Sec AT baat p Dual Controller Status Partner Status Ok Fault Tolerant Yes Kill Partner Relinguish Partner r Controller Specific Slot Number 0 Port Number 0 PotID 2 World Wide Name XX XX 00 80 e5 11 01 af Channel 0 Target 2 Controller Options l Figure 5 11 Controller Information External RAID Controllers Manual No 771961 5 11 Controller Monitoring The following information is displayed e The controller model e The firmware version residing on the controller e The cache size e Whether an Intelligent Battery Backup Unit is installed N A for not supported on the current controller e The number of host ports on this controller e The number of drive channels on the controller e The front end bus type SCSI FC AL of the controller e The front end bus width for data transfers and front end bus speed MB sec e The number of physical devices detected e The number of logical drives configured on this controller e Ho
10. standby disk drive of identical or larger size is found attached to the same controller e All of the system drives that are dependent on the failed disk are redundant system drives e g RAID 1 RAID 3 RAID 5 RAID 0 1 Note The automatic rebuild will only happen on the SAME controller never across controllers A Hot Spare disk can be created in one of two ways 1 When configuring via a Mylex configuration utility all disks attached to the controller that are NOT configured into any disk array will be automatically labeled as hot spare drives 2 A disk drive may also be added attached at a later time to a running system and labeled as a hot spare 3 The controller creates the hot spare During the automatic rebuild process system activity continues as normal System performance may degrade slightly during the rebuild process Manual No 771961 G 11 Glossary To use the automatic rebuild feature you should always maintain a hot spare drive in your system When a drive fails the hot spare will automatically replace the failed drive and the data will be rebuilt The system administrator can disconnect and remove the bad drive and replace it with a new drive The administrator can then make this new drive a hot spare Stripe Order The order in which disk drives appear within a drive group This order must be maintained to access the data correctly and is critical to the controller s ability to Reb
11. E Eal M Controller 0 Port 1 lt i lz M Controller 1 Port 0 R 5 M Controller 1 Port 1 0 125 fro 4 E Cancel Figure 4 26 Fibre Controller Options Dialog Box In the Fibre Controller Options dialog box Figure 4 26 you have the option to do any of the following Enable Disable Node Name Retention When enabled each controller shares its node name with its partner controller and those names are used through all phases of failover and failback e Set Hard Loop IDs for each controller and port combination Enable a controller port combination by checking its check box Values allow use of the same Loop IDs all the time Some Fibre HBAs work better with this 4 30 GAM Client v2 30 and WSAM User s Manual Configuration e Set PCI Latency Control Controls the amount of data each Front end Fibre Protocol Processor can burst across the primary PCI bus before relinquishing bus ownership Settings are Short Medium Long A setting of Long is recommended e Set Frame Control Allows adjustment of the FC chip s frame size Recording Your Changes Click OK in the Advanced Controller Options Expert Controller Options and or Fibre Controller Options dialog boxes to accept the changes or the Cancel button to delete them SCSI Host Bus Adapters Controller Options 7 1x SCSI Device Parameters SCSIID fo x k Asynchronous C SMHz a 10 MHz C 20 MHz V Enable Di
12. Figure 4 1 Sign On 2 x Server 204 32 130 202 Username gamroot Password IV Remember password for this session Cancel Figure 4 1 Sign On Dialog Box 4 2 GAM Client v2 30 and WSAM User s Manual Configuration Open Sign On at any time as shown in Figure 4 2 Define Server Groups Select Current Server Group Ctri G Select Current Controller Ctrl C Raid Assist Initialize Logical Drives Controller Information Enclosure Information Controller Options Intelligent BBU Scan Devices Advanced Functions Settings Figure 4 2 Select Sign On Do the following 1 Type the password previously enabled on the server that corresponds with username gamroot This should provide Administrator access privileges 2 Check the box labeled Remember password for this session if you want GAM to refrain from Sign On messages each time you select a server during this session which uses the same password This amounts to automatic sign on on additional servers and should be used with caution Uncheck the box if you want to retain the option of signing on to each server you wish to access individually 3 Click the Sign On button Manual No 771961 4 3 Setting Up Server Groups and Servers Setting Up Server Groups and Servers Adding a Server Group to the Server Group List Open Define Server Groups as shown in Figure 4 3
13. Running RAID Assist Manual Configuration New Configuration 204 32 130 202 Controller 2 aD DekteDive Coal Figure 4 45 Sample Manual Configuration Just Before Apply Note In Manual Configuration Add Logical Drive and Expand Array function very similarly to what was shown above In each of these two cases however RAID Assist shows you the disk arrays and logical drives and allows you to add to the configuration without risking existing data 4520 GAM Client v2 30 and WSAM User s Manual Configuration External RAID Controller Operation Overview External RAID Controllers use their host ports to connect to one or more Host Bus Adapters in one or more host computer systems Depending on the model and configuration of the controller there may be from one to four host ports Each configured logical drive consumes a particular bus target ID LUN on the host system Multiple sets of disk drives are connected to the controller via its drive channels There may be as many as six drive channels depending on the controller model and configuration In duplex or Active Active mode two identical External RAID Controllers are connected to the same hosts via their host ports to the same drives via their drive channels and to each other via a special hardware link for heartbeat sensing This forms a redundant controller system The two controllers work together handling data traffic and mirror their write dat
14. e Coalesce Device Queues Joins data from adjacent I Os into a single T O to improve performance e Super Read Ahead SRA Extends the Read Ahead process by always reading an extra cache line on a read request and reading an additional cache line when a cache hit occurs Most useful for applications where read sequential data is high e True Verification Of Data Performs a true verify with data comparison e Write Through Verify During error handling this turns on Force Unit Access for reads and writes e Operational Fault Management Allows the controller to take autonomous actions when a failure occurs Do not disable this function unless specifically instructed to do so as part of a troubleshooting diagnostic activity e Disable by checking or enable by unchecking the following option e Wide Transfer On Host When disabled the controller will negotiate only narrow data transfers Doing this unnecessarily will result in slower performance 4 26 GAM Client v2 30 and WSAM User s Manual Configuration Expert Controller Options All External RAID Controllers Click the Expert button in the Advanced Controller Options dialog box to inspect and or change expert level External RAID Controller Options These options should remain at their defaults unless you have a high degree of expertise with External RAID Controller Options Expert Controller Options 2 x r General m Host Bus Reset Delay I Enable Simplex No RS
15. 2 13 Installation of Global Array Manager Client or Workstation Array Manager The Setup Complete dialog box displays Figure 2 19 Setup Complete Figure 2 19 Setup Complete Restart the Computer 8 You must restart the computer before using Workstation Array Manager Make sure that the Yes I want to restart my computer now option is selected then click Finish to complete Setup and reboot Note If you have other tasks to perform before rebooting the system you may instead select the No I will restart my computer later option However for Workstation Array Manager to function properly you must implement a reboot before running WSAM for the first time 2 14 GAM Client v2 30 and WSAM User s Manual Chapter 3 Startup amp Navigation Starting Global Array Manager or Workstation Array Manager Server Component Note Installation and startup of the Global Array Manager Server component is covered in the Disk Array Controller Software Kit Installation Guide and User Manual Mylex Part Number 771929 The software for GAM Server is provided on the installation CD ROM Refer to the appropriate sections in the above mentioned manual for instructions on starting the Global Array Manager Server component under any of the following network operating systems e NetWare 4 11 4 2 or 5 0 e Windows NT 4 0 e SCO OpenServer 5 0 4 e UnixWare 2 1 x or 7 0 Client Component Note Install a
16. 5 18 Enclosure Monitoring and Management s src 5 20 SCSI Enclosures scien wk cniteal ee hen ahead 5 20 SES and SAF TE Fibre Enclosures n 5 21 Performance Monitoring scceeeseeeeeseeeeeneeeeeneeeseeeeeeneeeesneeereaeees 5 26 slatistics View 2 23 Gash ie ie dice dati T 5 26 Performance Analysis cccceeesseeeeeeeeeneeeeeseeteneeeeneeeeeeeeee 5 36 Process Status Monitoring eeceeecceeseeeeeeeeeeeeeeeeeeeeeeeeaeeeeeeeeeeeeas 5 43 Initialization Status oo cece eeeeeeseeeeeeeeeeecneeeeaeeeeesseeseaeeeeeeeeas 5 43 Rebuild Status 2 2 E E EN 5 45 Consistency Check Status 00 eecececeeeeeeeeseeeeeeeeeeeeteeeeneeeeaees 5 46 Expand Capacity Status 0 0 ceccecceseeeeeeneeeeeeeeeeeneeeeeeenneeaees 5 47 Battery Backup Unit Monitoring and Maintenance seese 5 48 Mylex PCI RAID Controllers 0 0 00 eee ete eee teeter reeeeees 5 48 Mylex External RAID Controllers 0 0c eee eerste 5 50 Chapter 6 Maintenance Processes Wnt GUCHONy keperitan a a a a gee 6 1 Running a Logical Drive Consistency Check cceeceeeeeeeeeeeeeeeeee 6 1 Running a Device Rebuild ee eeeeeeseeeeeneeeeeneeeeeneeeeenneeeeneeeeenaeeees 6 3 Using the Flash Utility eee eeeeeeneeeeeeneeeeseeeeeseeeeeeaeeeeneeeeesaeeeeea 6 5 Mylex PCI RAID Controllers 0 0ece eee eet ee eee tee eeeeteeeeees 6 5 Mylex External RAID Controllers 0 00 0 eee eee eee 6 8 Performing a Controller Shutdown eceeeceeeeeeeteeteeeeeee
17. 771929 For information on defining and setting RAID Redundant Array of Independent Disks levels and the configuration of disk arrays and controllers consult the RAID EzAssist Configuration Utility v1 00 User Reference Guide Mylex Part Number 775029 Conventions Throughout the manual the following conventions are used to describe user interaction with the product bold The user must enter the bold text exactly as shown al Press the Enter key or Enter Press the key labeled Enter or Delete etc File Run Select the Run option from the pull down menu activated when the File menu pad is selected Note Supplementary information that can have an effect on system performance A Caution Notification that a proscribed action has the potential to adversely affect equipment operation system performance or data integrity WARNING Notification that a proscribed action will definitely result in equipment damage data loss or personal injury Contents Chapter 1 Introduction OVENVICW 2s Se ei ei ete i eae ee 1 1 Global Array Manager Components cceceeeeeneeeeeeeeeeaes 1 2 Configuration Functions ceeeeeeeeeeeeeeeeeeeeeeeeaeeeeeseaeeeeeeneetaas 1 3 Monitoring Functions 000 eeceeeeeeeeeeeeeeseeeeeeneeeeseeeesaeeeeeneeeeeaes 1 3 Maintenance Functions ccceeesceeeeseeeeneeeeeneeeesseeeeseeeseeeeeeaes 1 3 What s New In GAM Version 2 30 cceeeseceeseeeeeeeeeeeeeeneeteee
18. Array Controller firmware e Performing a safe controller shutdown External Controllers only Running a Logical Drive Consistency Check From time to time it is prudent to run a consistency check on each of your fault tolerant logical drives This check scans the logical drive to determine whether consistency data has become corrupted and needs to be restored If you have reason to believe that logical drive consistency data is corrupted or if you wish to run a consistency check for maintenance reasons perform the following procedure 1 Double click a logical drive in Controller View right side of a Controller View window 2 Click the Consistency Check button in the Logical Drive Information dialog box to begin A message is displayed asking if you would like consistency to be restored in the event of errors Figure 6 1 Manual No 771961 6 1 Running a Logical Drive Consistency Check Consistency Check 7 Restore consistency if errors are found during the consistency check Figure 6 1 Restore Consistency If Errors Are Found 3 Click Yes to restore consistency during the process A Caution If consistency data is badly corrupted on a logical drive attempting to restore consistency may result in corrupted real data Use the Yes option with caution Click No if you just want to carry out the consistency check There is no risk of data loss Errors will still be reported to the Error Table but no attempt will b
19. Background Initialization is Supported 8 If this message appears click Yes to request a full foreground initialization of logical drives once the new configuration is applied OR Click No to take advantage of the background initialization support Once you ve applied your configuration your logical drives will be available for immediate use 4 44 GAM Client v2 30 and WSAM User s Manual Configuration Optimization Tab Figure 4 39 9 Choose between e write cache enabled write back or e write cache disabled write through 10 Select Stripe Size valid options are in the list 11 Select Cache line size see below Valid cache line size values depend on the stripe size setting and are listed appropriately once you ve selected a stripe size Assisted Configuration New Configuration 204 32 130 202 Controller 2 Fault Tolerance Raid Level Logical Drives Optimization Finish Figure 4 39 Assisted Configuration Optimization ManalNo 771991ss lt is sSSSSSSSSSS 5 Running RAID Assist Assisted Configuration New Configuration 204 32 130 202 Controller 2 1 Welcome 2 Fault Tolerance 3 RAID Level 4 Logical Drives 5 Optimization 6 Finish RAID Assist has completed the configuration i You can view details of the configuration by clicking Details button If you are satisfied with the configuration as defined below click the Apply Fault Tolerance button to implement the con
20. Bits Narrovw Enclosure Status Power B Temperature B Figure 5 18 Processor Device Enclosure Information SCSI Processor Device Information Figure 5 18 displays the following about the currently selected enclosure processor Processor Enclosure Information SCSI e Device Inquiry Data information such as vendor product product revision bus width etc e Device State information such as transfer speed and bus width e Enclosure Status information for power temperature and fan where Green is OK Yellow is Critical and Red X is Failed Click the Close button to close the dialog box 5 20 GAM Client v2 30 and WSAM User s Manual Monitoring SES and SAF TE Fibre Enclosures The Controller View window for Mylex External Fibre Channel Controllers contains an Enclosure button with a status light Green indicates OK Yellow indicates Critical status and a Red X indicates failed status You can monitor information status and additional details about SES and SAF TE enclosures used with Fibre Channel controllers by clicking the Enclosure button in Controller View Alternatively you can select Enclosure Information from the Administration menu as shown in Figure 5 19 Sign On Define Server Groups Select Current Server Group Ctri G Select Current Controller Ctrl C Baid Assist Initialize Logical Drives Controller Information Enclosure Information Controller Options
21. E ELD Em Y Ek g Eil Enable AllHosts m Host To Logical Drive Mapping Lun Selection E H 2 000000000000 MX xx 0 Raid 130MB 0 00 00mm x XX 1 Raid0 230MB 0 X XX 2 Raid0 300MB XXX 3 Raid0 430MB 3 X XxX 4 Raid FNM 4 XX 5 Raid0 33212M8 5 x XxX O0a0a0a0a0a0a Da0 X X X flick xX xX B NatComectec Connected Found Set Sequential Clear ll Restore Apply Zance n Figure 4 46 A Host to LUN Mapping Scenario Selecting the Topology Host to LUN mapping provides the user with four possible dual active controller configuration topologies e Inactive Port Controller 0 port 0 and controller 1 port 1 are active During failover the inactive port on the partner takes over for the active port on the failed controller Supported on all products with two host Fibre ports e Master Slave Both ports on controller 0 are active During failover controller 1 assumes control Manual No 771961 4 55 External RAID Controller Operation Overview e MultiPort All ports are active This topology is supported on all Fibre attached products running Firmware v6 0 or above Note that this topology does not provide transparent failover failback and requires an alternate path driver in the host e Multi TID AII ports are active This topology is supported on all Fibre products with ISP2200 hardware FFx MFF etc and Firmware v6 0 or above This topology p
22. Manager Files c program files mylex workstation array manager mfc42 dll Figure 2 16 Installation Progress Display 4 After installation completes the following message appears Figure 2 17 Question Q Do you want to enable Mylex External RAID Controller Support Figure 2 17 Enable External RAID Controller Support e If you will be using Mylex External RAID Controllers click Yes OR e If you will be using only Mylex PCI RAID Controllers click No If you click Yes Setup makes some minor adjustments in the GAM configuration file to facilitate External RAID Controller operation 2 12 GAM Client v2 30 and WSAM User s Manual Installation The following display appears Figure 2 18 View Readme Files Figure 2 18 View ReadMe File 5 To view changes and updates to the program or installation guide check the box which reads Read the Workstation Array Manager readme file now then click Next 6 If you chose to view the ReadMe file the Notepad accessory will open and the file will be presented Read the contents of this file for the most up to date information about Workstation Array Manager Much of this information may not appear in this installation guide as sometimes last minute modifications to the software are done after completion of the guide You may also wish to print the contents of this file 7 Close the Notepad accessory after reading and or printing Manual No 771961
23. Mapping configuration to the mapping that was assigned at the time RAID Assist was entered If editing an existing configuration the original mapping is read from the firmware A new configuration reverts to the default mapping Enable All Hosts Cancel The Cancel button cancels the entire configuration including what was set up under the Disk Arrays Logical Drives and LUN Mapping tabs If you want to cancel only your LUN Mapping changes use the Restore button Apply The Apply button applies the entire External RAID Controller configuration including what was set up under the Disk Arrays Logical Drives and LUN Mapping tabs Click Apply when you are ready to accept the entire External RAID Controller configuration you ve specified across all Manual Configuration tabs There will be a confirmation message followed by a Do You Want To Reset message Reset will take a couple of minutes Manual No 771961 4 59 External RAID Controller Operation Overview 4 60 GAM Client v2 30 and WSAM User s Manual Chapter 5 Monitoring Introduction Monitoring activities involve the following e Monitoring events messages sent by various servers to the client workstation s e Monitoring controller activity reviewing controller configuration and other information e Reviewing physical device and logical drive information e Viewing Error Table information and Request Sense Data e Monitoring and managing SCSI and Fibre
24. Monitoring To save all your settings to a file for future use 1 Click Save Settings A Save As dialog box is displayed Figure 5 33 Save As 1 1x Save in 5 3 Floppy A f E a setting gst File name Jpertsetd Save as type cam Settings Files gsf z Cancel Figure 5 33 Save Settings to a File 2 Enter a destination and filename for your settings file 3 Click Save To use previously saved settings 1 Click Open Settings An Open dialog box is displayed Figure 5 34 Open MEI Look in 5 3 Floppy A z al f Er File name perfsett gsf Files of type cam Settings Files gsf 7 Cancel Figure 5 34 Open Previously Saved Settings 2 Enter a destination and select the settings file you wish to open 3 Click Open Manual No 771961 5 39 Performance Monitoring The data generated by your analysis strings can be captured to a file This file can be opened later for examination or analysis To capture data to a file 1 Click Capture Data A Capture Data dialog box is displayed Figure 5 35 Capture Data 24 x File Name pertdata Browse Capture Type Save Butter Start Capture cme Figure 5 35 Capture Data to a File 2 With Start Capture selected type a filename for the data file to be saved or click Browse to find an existing data file and append to it 3 Click OK Data defined by your analysis strings will be ge
25. Monitoring and Management on page 5 20 for more details Manual No 771961 5 7 Controller Monitoring SCSI Host Bus Adapters Channel 0 Figure 5 7 SCSI HBA Controller View With Multiple LUN Device Figure 5 7 above shows the Controller View for a typical SCSI Host Bus Adapter The special icon appearing on Channel 0 Target ID 0 indicates that a multiple LUN device is present at that location Supported multiple LUN devices in GAM are External RAID Controllers such as a Mylex DAC960SX Viewing the configuration from the SCSI HBA s point of view in this way you can actually see the logical units connected to the External RAID Controller by double clicking the special controller icon When you do a Target ID View emerges showing basic information about the LUNs configured on that External RAID controller Figure 5 8 5 8 GAM Client v2 30 and WSAM User s Manual Monitoring Target ID View Channel 0 P Eg Logical Units MB Target 0 Figure 5 8 LUNs on Target 0 a Multiple LUN Device Four LUNs are available in the example above LUN 0 through LUN 3 Note In order to configure devices on an External RAID Controller you must select the RAID controller directly in the controller selection box then run RAID Assist SCSI HBA and Target ID views only allow you to see what s connected to the External RAID Controller For additional details about the devices LUNs you must also access the RAID con
26. O1 07 199R__ 17 17 1998 327RA Fa 4 gt Start Flash Close Figure 6 6 Additional Flash File Information 4 Compare the information for the new IMG with the current information to confirm that a flash is warranted for example that the IMG contains a newer version of code 5 Click Start Flash Because flashing new code to the controller erases what was there previously two levels of confirmation are required to proceed with the flash 6 Click OK at the first confirmation message 7 Type YES then click OK at the second confirmation message The controller will be updated with the new code contained in the IMG file Manual No 771961 6 7 Using the Flash Utility Mylex External RAID Controllers The Flash Utility is used to upgrade firmware by flashing the new code stored in an identified IMA file to the on board flash memory As maintenance releases of this code become available this utility allows you to keep your controller current using GAM or WSAM The Flash Utility dialog box appears as shown in Figure 6 7 Flash Utility x m Flash file selection Figure 6 7 Flash Utility Dialog Box The Flash Utility dialog box comes up with no information specified To do a flash upgrade 1 Type the name of the appropriate image file IMA in the Flash file selection box or click the Browse button to locate the file If you select Browse the Open Image
27. an external Fibre Channel controller may not be displayed in the stack of physical devices in the Controller View window The controller device information is available through the controller information window described on page 5 11 A physical device icon representing an enclosure processor may not be displayed in the stack of physical devices in the Controller View window The enclosure information is available through the Enclosure button in Controller View or the Enclosure menu item in the Administration menu Host Device Information Channel 0 Target 7 Lun 0 r Device Inquiry Data Vendor MYLEX Product DACSBOSK 55T1 Revision 4419 Bus Width 16 Bits Vvide Sync Yes Soft Reset No ANSI Version SCSI 2 Linked No CmdQue Yes p Device State Transfer Speed 20 MB Sec BusvVVidth 16 Bits V Vide Figure 5 12 Host Device Information RAID Controller Manual No 771961 5 13 Physical Device and Logical Drive Monitoring Disk Device Information Channel Target Lun 0 m Device Inquiry Data Vendor SEAGATE Product T118202FC Revision 0007 Bus Width 1 Sync No Soft Reset No ANSI Version SCSI 2 Linked Yes CmdQue Yes Serial LK426771 m Device State Nego Transfer Speed 100MB Sec Capacity 17366MB Status Dead ER Failure Indicator Nego Bus Width H Sector Size 512 Bytes 20 StartDev01 m Device Errors Soft Errors 0 Parity Errors 0 Hard E
28. configuration has been applied Assisted Configuration New Configuration 204 32 130 202 Controller 2 1 Welcome 2 Fault Tolerance 3 RAID Level 4 Logical Drives Optimization 6 Finish Assisted configuration will create logical drives from the capacity and number of logical drives you specify Fault Tolerance afl Raid Level How many logical drives do you want to create fi 4 Logical Drive How much capacity do you want to use fioo 112408 MB Optimization Finish Selecting initialize will initialize all logical drives Do you want to initialize logical drives Yes C No lt Back Next gt Cancel Figure 4 37 Assisted Configuration Logical Drives Certain Mylex PCI RAID Controllers allow Immediate RAID Availability of logical drives after configuration For these controllers initialization can take place in the background without the need to wait for full foreground initialization If you selected Yes to the question above and the controller supports background initialization the following screen will appear Figure 4 38 Manual No 771961 4 43 Running RAID Assist Global Array Manager 9 Background initialization is supported by the controller By selecting No the drives will be automatically initialized in the background By selecting Yes foreground initialization will be done Are you sure you want to do foreground initialization Figure 4 38
29. enclosure information e Monitoring the performance of drives and controllers reviewing historical performance data Statistics View and Performance Analysis e Monitoring the status of ongoing processes such as initialization rebuild consistency check and expanding capacity of an array e Monitoring the status of an Intelligent Battery Backup Unit BBU and recharging reconditioning the battery if needed External only Event Monitoring Global Array Manager Server and the Workstation Array Manager driver subcomponent monitor activity and performance of all devices and controllers attached to the server When an identified activity occurs which results in an event whether severe such as a hard disk failure or informational such as assignment of a drive to hot spare status the event is sent to selected workstations running GAM Client WSAM Events are displayed in the Log Information Viewer An event can be any of the following e Server attach and detach Guest User and Administrator e Error or warning condition in a RAID subsystem such as a power fan or drive failure Manual No 771961 5 1 Event Monitoring e Any administrative activity taking a drive off line killing or rebuilding a drive Note It is recommended that the Global Array Manager Client or Workstation Array Manager be kept active continuously as a minimized Windows application Opening the Log Information Viewer The Lo
30. logical drive Logical Drive 0 Information 71 x RAID Level 5 Fault Tolerant Yes Optimized for Speed Yes Optimized for Capacity Yes Logical Size 500 MB Physical Size 600 MB Stripe Size BKB Cache Line Size BKB Write Cache Enabled Status OFFLINE Used Array Capacity AO Used 600 MB Total 104198 MB Used Capacity CJ Unused Capacity Force On Line Show Bad Data Blocks sone teneI CHECK Disable Vite Cache Figure 5 17 Logical Drive Information for a RAID Controller Logical Drive Information Figure 5 17 displays the following about the currently selected logical drive 5 18 The logical drive number in the window s titlebar The RAID level at which the logical drive is configured Whether the logical drive s configuration is optimized for speed optimized for capacity and fault tolerant Yes No The logical and physical size of the logical drive The stripe size and cache line size in use by the logical drive Whether write back cache is enabled or disabled The operational status of the logical drive Out of the total amount of capacity configured on the controller the amount of capacity held by this logical drive shown in a bar graph GAM Client v2 30 and WSAM User s Manual Monitoring If write back cache is disabled click the Enable Write Cache button to enable the cache If write back cache is enabled click the Disable Write Cache button to disable the cac
31. you want a Hot Spare Yes No Assisted Configuration New Configuration 204 32 130 202 Controller 2 Fault Tolerance Raid Level Logical Drives Optimization Finish Figure 4 34 Assisted Configuration Fault Tolerance 440 GAM Client v2 30 and WSAM User s Manual Configuration RAID Level Tab If Fault Tolerance Was Yes Figure 4 35 3 Choose between e Parity error correction RAID 5 RAID 3 or e Fully redundant drives RAID 1 RAID 0 1 Assisted Configuration New Configuration 192 9 10 201 Controller 0 Fault Tolerance Raid Level Logical Drives Optimization Finish Figure 4 35 Assisted Configuration RAID Level With Fault Tolerance Manual No 771961 4 41 Running RAID Assist RAID Level Tab If Fault Tolerance Was No Figure 4 36 4 Choose between Striping RAID 0 or e Stand alone drive JBOD Assisted Configuration New Configuration 204 32 130 202 Controller 2 Fault Tolerance Raid Level Logical Drives Optimization Finish Figure 4 36 Assisted Configuration RAID Level With No Fault Tolerance 4420 GAM Client v2 30 and WSAM User s Manual Configuration Logical Drives Tab Figure 4 37 5 How many logical drives do you want to create 1 32 for PCT 1 8 for External 6 How much capacity do you want to use default 100 available space or equivalent in MB 7 Do you want to initialize logical drives Yes No This is done after the
32. 2 30 and WSAM User s Manual Configuration 4 Check the Init Drive box if you want this logical drive to be fully initialized at the conclusion of the configuration It is recommended that you check this option if available unless the controller is capable of background initialization If so and you check the box you ll see a message when you apply the configuration indicating that you can make use of the background initialization support 5 If this is your first logical drive select a stripe size This setting will apply to all logical drives on this controller 6 If this is your first logical drive select a cache line size Available settings will depend on the selected stripe size Not available for External RAID Controllers 7 Click the Add Drive button to register your new logical drive 8 If you are configuring a Mylex PCI RAID Controller click Apply to save the configuration if you are finished setting up logical drives OR Repeat the process above to set up additional logical drives then click Apply when you re done If you are configuring a Mylex External RAID Controller click the LUN Mapping tab to continue with configuration see Host to LUN Mapping in Global Array Manager on page 4 55 OR Repeat the process above to set up additional logical drives then click the LUN Mapping tab when you re done An example of a completed Manual configuration is shown in Figure 4 45 Manual No 771961 4 51
33. 8 Installation of the Workstation Array Manager component requires the Windows NT 4 0 operating system Note You may install either Global Array Manager Client OR Workstation Array Manager during an installation session but not both at the same time This chapter assumes that the network administrator for this site will be performing these installation procedures If you are installing GAM Client you may also choose to install GAM Server and its subcomponents at the same time on the same system When installing GAM Server dialog boxes for the server component appear and require a computer restart before launching the GAM Client software Refer to the Disk Array Controller Software Kit Installation Guide and User Manual P N 771929 for GAM Server installation instructions Manual No 771961 2 1 Installation of Global Array Manager Client or Workstation Array Manager Installation of Global Array Manager Client or Workstation Array Manager File List Global Array Manager and Workstation Array Manager software are shipped on an accompanying distribution CD ROM The file list and path is as follows where X represents the drive letter of your CD ROM drive X AGAM NTI _INST321 EX_ DATA TAG SETUP EXE _ISDEL EXE DATA1 CAB SETUP INI _SETUP DLL LANG DAT SETUP INS _SYS1 CAB LAYOUT BIN SETUP LID _USER1 CAB OS DAT Beginning the Installation and Selecting Components 1 If you intend to install GAM Server or GAM Cli
34. 9 Setting and Modifying User Preferences M Enabled Modem Setup String fat amp F amp C1 amp D2L1 r Phone Prefix fatoT ts Number 555 234 Sufix Delay LY Modem Hangup String p ATHO m Pager Type Numeric Alphanumeric Advanced Test Cancel Figure 4 11 Pager Setup Dialog Box 3 In the Pager box Enable or disable this Pager entry using the Enabled check box Enter the Modem Setup String or keep the default Enter a Pager Prefix or keep the default Enter the phone number of someone who will receive a page Enter a Pager Suffix if needed Enter a Pager Delay interval The value of each comma is 1 second Enter the Modem Hangup String or keep the default Note Please consult your modem manufacturer or modem documentation for the specific string which works best with your modem Select the appropriate button for a Numeric or Alphanumeric pager 4 Ifyou need to enter a Message Prefix Suffix or Delay interval click Advanced Enter the desired information and click OK to return to the Pager setup box 4 10 GAM Client v2 30 and WSAM User s Manual Configuration 5 To test the pager using the settings you ve input click Test 6 When you are satisfied with the Pager you ve set up click OK Your new Pager entry appears in the lower window of the Alarm Setup dialog box Refer back to Figure 4 10 for an example Remove a Pager 1 Select t
35. 9 00 23 1997 14 otl 4 logdry 0 00055500 Thu Sep 25 19 00 23 1997 13 otl 4 logdry 0 00055400 Thu Sep 25 19 00 23 1997 12 otl 4 logdry 0 00055300 Thu Sep 25 19 00 23 1997 1 otl 4 logdry 0 00055000 Thu Sep 25 19 00 23 1997 10 otl 4 logdry 0 00055100 Thu Sep 25 19 00 23 1997 4 otl 4 logdry 0 00055380 Thu Sep 25 19 00 23 1997 8 otl 4 logdry 0 00055280 Thu Sep 25 19 00 23 1997 7 otl 4 logdry 0 00055100 Thu Sep 25 19 00 23 1997 6 otl 4 logdry 0 00055080 Thu Sep 25 19 00 23 1997 5 otl 4 logdry 0 00055980 Thu Sep 25 19 00 23 1997 4 otl 4 logdry 0 00055880 Thu Sep 25 19 00 23 1997 Figure 5 15 Bad Block Table This table contains information about bad unusable areas on currently configured logical drives and the date and time when the errors were discovered A large number of bad blocks may signal a corrupted or failing disk 5 16 GAM Client v2 30 and WSAM User s Manual Monitoring e Click Save File to record the bad block information for later inspection If you click the Request Sense Data tab the following type of information appears Figure 5 16 Error Table 12 xi Bad Block Table Request Sense Data Device Address Sense Message Sense Data Tin 11 otk 2chn 1 tgt 3 lun 0 Unit Attention 700006 0000000004 00 00 00 0029000000 Fri 10 oth 2 chn 1 tgt 1 lun 0 Unit Attention 70 00 06 00 00 00 00 QA 00 00 00 0029000000 Fri 9 otl 2 chn 1 tgt 0 lun 0 Unit Attentio
36. 999 ctl O chn Otgt 6 Power on reset or bus device reset o i Thu Mar 18 15 46 17 1999 ctl O chn Otgt 5 Power on reset or bus device reset o For Help press F1 ZA Figure 3 2 Opening WSAM Screen Components of the Workstation Array Manager Window The major components of the Workstation Array Manager window Figure 3 2 are described below 1 Item 1 is the WSAM menubar There are five menus with several selections each The contents of the menus and the functionality of several of the most important selections will be described throughout this guide 2 Item 2 is the WSAM toolbar There are eight toolbar icons representing eight of the most useful functions available in WSAM The identity of each toolbar icon and an explanation of the purpose of each will be described in later sections of this chapter 3 6 GAM Client v2 30 and WSAM User s Manual Startup amp Navigation 3 Item 3 is the server selection box Workstation Array Manager does not allow access to remote servers so this box is read only and contains the entry LOCAL_SERVER The server selection box is used only in GAM Client 4 Item 4 is the WSAM controller selection box When selected the box displays the controller ID C 0 C 1 etc and controller type BT 952 DAC960PJ etc of each SCSI HBA and PCI SCSI or External RAID Controller connected to the local server For External RAID Controller duplex pairs a double pointed white arrow connect
37. All button which deselects all drives for cancellation Click Close to close the Initialize Status box at any time 5 44 GAM Client v2 30 and WSAM User s Manual Monitoring Rebuild Status If a rebuild process is currently underway open the Rebuild Status box as shown in Figure 5 40 to monitor the progress of or cancel the process Figure 5 40 Select Rebuild Status Rebuild Status Controller 2 Figure 5 41 Rebuild Status Box The Rebuild Status box Figure 5 41 displays the progress of a physical drive rebuild The command rebuilds all logical drives that occupy any portion of the targeted physical drive Click Cancel to stop the rebuild You may need to check the Views menu to see if Rebuild Status is still enabled If so you may need to cancel other rebuilds as well Click Close to close the Rebuild Status box at any time Manual No 771961 5 45 Process Status Monitoring Consistency Check Status If a consistency check process is currently underway open the Consistency Check Status box as shown in Figure 5 42 to monitor the progress of or cancel the process Global Status View Controller View Statistics View v Log Information Viewer Initialize Status Rebuild Status Error Table Figure 5 42 Select Consistency Check Status Consistency Check Status Controller 3 24 x Current Logical Drive 0 m 28 Completed ST lll s S SS
38. Click Open The data generated by your analysis strings can be captured to a file This file can be opened later for examination or analysis To capture data to a file 1 Click Capture Data A Capture Data dialog box is displayed Figure 5 26 Capture Data 2 x File Name data1 Browse Capture Type l Save Buffer Start Capture ome Figure 5 26 Capture Data to a File 2 With Start Capture selected type a filename for the data file to be saved or click Browse to find an existing data file and append to it 3 Click OK Data defined by your analysis strings will be generated You can see the data as a line graph pie graph or bar graph Data will be collected until you click the Stop Capture button You may wish to save the contents of the data buffer to a file for later examination To save the data buffer to a file 1 Click Capture Data 2 Select Save Buffer and type a filename for the data file to be saved or click Browse to find an existing data file and append the buffer to it 3 Click OK 5 30 GAM Client v2 30 and WSAM User s Manual Monitoring To display previously saved data 1 Click Display Data A display Data dialog box opens Figure 5 27 Display Data 2 x Data Source f204 32 130 200 Browse data1 sdf Cancel Figure 5 27 Display Data 2 Select a data file to display or click Browse to locate a data file in a different directory
39. Controller Status click Cancel to exit the dialog box The user may now power off the controller The battery will remain charged and will not supply power to the cache To abort a shutdown or return a controller to normal operation 1 Click Return to Normal Operation 2 Click Cancel to close the dialog box then continue normal use of the controller through GAM WSAM To update status information from the controller during shutdown e Click Refresh 6 12 GAM Client v2 30 and WSAM User s Manual Appendix A Error Codes Overview Global Array Manager provides information about drive and controller failures as well as maintaining an event log Global Array Manager classifies the events it records into five severity levels described in Table A 1 Table A 1 Severity Level Priorities and Descriptions Severity Description 0 Controller failure 1 Serious The failure of a major component within the array enclosure For example a power supply fan or physical drive 2 Error A consistency check fails or a rebuild on a drive stopped because of errors 3 Warning Global Array Manager has failed to kill a drive or failed to start a rebuild 4 Informational Messages such as sign ons and system startups When a consistency check or a rebuild has finished for example or a physical drive has been put on standby Critical Level 0 388 Controller is dead System is disconnecting from this controller 391 Controller is go
40. N Selection field and the Enable All Hosts check box become active If a LUN assignment exists for the logical drive it is displayed in the LUN Selection field If no assignment exists for the logical drive None is displayed The LUN assignment drop down box displays all valid LUNs that may be assigned to the selected logical drive Enable All Hosts allows a logical drive LUN assignment that is enabled for all hosts on the loop This allows all hosts on the loop access to the logical drive through the LUN without having to redefine the mapping as new hosts are added to the loop Enable All Hosts mapping is the default mapping for all new configurations and old configurations that are converted to new configurations Note Enable All Hosts can generate an error if another logical drive is sharing a LUN with the logical drive being enabled and hosts have been assigned to the logical drive The operation is not allowed Host to Logical Drive Mapping Host to logical drive mapping associates hosts on the fibre channel loop to logical drives The hosts are displayed on the left side of the list including the state of the host and the host s identity either WWN or IP address Note The host identity is the WWN World Wide Name of a Host Bus Adapter HBA of a server computer on the IP network on the fibre channel loop An attempt is made to find the server Servers with multiple HBAs have an ordinal number in parentheses after t
41. NINYLEX MOVING DATA gt SMARTER Global Array Manager Client Software v2 30 with Workstation Array Manager Installation Guide and User Manual P N 771961 07 MINVLEX Global Array Manager Client Software v2 30 with Workstation Array Manager Installation Guide and User Manual Part Number 771961 07 Copyright 1999 Mylex Corporation All Rights Reserved All contents of this manual are copyrighted by Mylex Corporation The information contained herein is the exclusive property of Mylex Corporation and shall not be copied transferred photocopied translated on paper film electronic media or computer readable form or otherwise reproduced in any way without the express written permission of Mylex Corporation Greetings Thank you for purchasing the Mylex Global Array Manager Client Software v2 30 with Workstation Array Manager Requests for technical information about this and other Mylex Corporation products should be made to your Mylex authorized reseller or Mylex marketing representative Please Notice Mylex is a registered trademark of Mylex Corporation Global Array Manager Workstation Array Manager RAID Assist and DAC960 are trademarks of Mylex Corporation Novell and NetWare are registered trademarks of Novell Inc SCO SCO UNIX and UnixWare are registered trademarks of The Santa Cruz Operation Ltd Windows Windows NT Windows 95 Windows 98 Microsoft Exchange and Microsoft At Work F
42. Note Selecting the IP Address in the Data source box indicates that you wish to view data currently being generated by that server Only the currently selected server will be displayed 3 Click OK to open the data file for display or the server currently generating data You view saved data by clicking the Line Graph tab and choosing Past in the Graph Data box You view current data by clicking the Line Graph tab and choosing Present in the Graph Data box or by clicking the Pie Graph or Bar Graph tab Manual No 771961 5 31 Performance Monitoring Line Graph Click the Line Graph tab to open the Line Graph data page Figure 5 28 Statistics 204 32 130 200 x Settings Line Graph Pie Graph Bar Graph o 1 2 3 4 6 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 26 Visible Y multiplier Y offset Y autoscale Value Yes 1 0 0 Yes 63 66 Yes 1 0 0 Yes 7 65 Device Operation 0 CtlO Chn Tgt0 Tote Reads CtO Chn Tatl Tat Reads Time Scale Unit H Graph Data g sec Apoy C Past Present Pause Graph Wpticns Figure 5 28 Statistics View Line Graph Display The Line Graph page displays data for the analysis strings specified in the display window in the form of lines generated on a grid with time units along the horizontal axis and percentage along the vertical axis To set the Time Scale Unit 1 Enter a number of seconds in the tex
43. TCOM 10 Jo Enable Lett Sommetic REDE Alacrithm H gt T Enable On Q Full Give Busy T Enable Vendor Unique Test Unit Ready Stat Controller Present Fault Signals I Enable No Pause On Controller Not Ready I Enable Gea Sete I Disable CC For Invalid LUN I Enable Auto Restore m Debug Port Usage I Enable Force Simplex SLP VT100 Speed je I Enable Reset Propagation Debug T Enable Multi port Reset Figure 4 25 Expert Controller Options Dialog Box In the Expert Controller Options dialog box Figure 4 25 you have the option to do any of the following e Enable by checking or disable by unchecking any of the following options e Simplex No RSTCOM Allows a controller not to assert a reset signal to its partner controller Simplex environments only Left Symmetric RAID5 Algorithm Changes a Right Symmetric RAID 5 parity scheme to Left Symmetric This item is available only when there are no logical drives defined e On Q Full Give Busy When a command is received and the controller detects a full queue it will return a busy status rather than Queue Full This helps hosts that do not accurately deal with Manual No 771961 4 27 Setting and Modifying Controller Options Queue Full status e Vendor Unique Test Unit Ready Status Enables a vendor unique TUR effect A TUR sent to an offline LUN will get a hard error status returned e No Pause On Controller Not Ready Wh
44. The Pie Graph page displays data for the analysis strings specified in the display window in the form of a pie chart Note Because of the nature of a pie chart the Operation selected for your analysis strings should be the same If it is not the data may or may not be useful To update the data in the pie graph to the most current data e Click Refresh Display To exit e Click Close to exit from Statistics View OR Click another Statistics View tab 5 34 GAM Client v2 30 and WSAM User s Manual Monitoring Bar Graph Click the Bar Graph tab to open the Bar Graph data page Figure 5 30 Statistics 204 32 130 200 x Settings Line Graph Pie Graph Bar Graph Device Scale CtlO Chn Tat0 T gt2 T gt4 Reads S 100 88 1 CHlO Chn T gt T ot5 T ot6 Reads ssc 100 84 Reset Max Close Figure 5 30 Statistics View Bar Graph Display The Bar Graph page displays data each of the analysis strings specified in the display window as a separate bar To reset the maximum value if values consistency go off the scale e Click Reset Max The gray portion of the bars displayed in the upper window gives an indication of a maximum value that was hit relative to the current data in the colored bars In the example in Figure 5 30 both data bars are currently performing under their previous maximum values To exit e Click Close to exit from Statistics View OR Click another Statistics Vi
45. Write recovery failed Write recovery failed Write recovery failed Write recovery failed Write recovery failed Write recovery failed Write recovery failed Write recovery failed Write recovery failed Write recovery failed Write recovery failed Write recovery failed Write recovery failed New drive state is DEAD Standby rebuild bit set State is DEAD Error Codes A 5 Physical Disk Drive Failure Codes 23 StartDev04 30 BusReset01 31 BusReset02 40 MaxConsecBusy 41 DoubleCc 42 MaxSelTimeout 43 CcDeferred 44 MaxPerr 45 MaxResCnflct 46 MaxCcUatten 47 MaxCmdTmout 50 DevStatus01 51 DevStatus02 60 Restart01 61 Restart02 62 Restart03 63 NewCfigFail 70 ScanSelTmo 71 ScanMaxCc 72 DevInsertFail 73 DevInsertOffl 74 UncfigDev01 75 UncfigDev02 76 UncfigDev03 77 BadCodId01 78 BadCodId02 79 DevRoamDead A 6 Failed Bus reset did not clear dead channel Bus reset did not clear Max consecutive busy status count exceeded Check condition status on request sense command Max consecutive selection timeout count exceeded Check condition with sense data deferred error Max consecutive accumulated parity error count exceeded Max consecutive reservation conflict status count exceeded Max consecutive unit attention count exceeded Max Accumulated command timeout count exceeded New state is DEAD Start device failed Failed restart Failed restart Faile
46. WriteThrough Verify Expert Uk Figure 4 24 Advanced Controller Options Dialog Box In the Advanced Controller Options dialog box Figure 4 24 you have the option to do any of the following e Set the following limits e Queue Limit Maximum allowed queue depth for tagged commands to each attached drive Settings are from no tags to 230 e MAXIOPs Limit Sets maximum number of IOP structures allowed for controller command operations limiting the number of simultaneous commands Settings are from 64 to 244 e Enable by checking or disable by unchecking any of the following options e Conservative Cache Mode Turns off write cache while a failover condition persists allowing an extra degree of data safety e SAF TE Use of UPS Enables monitoring of uninterruptable power supply if it is also supported by the system enclosure e Restrict Reassign to One Block Restricts a reassign to the failing block If disabled reassigns will be for the entire current I O blocks Manual No 771961 4 25 Setting and Modifying Controller Options not all of them failing e Smart Large Host Transfers For transfers larger than the stripe size allows selection of Coalesce fewer disconnects on host data transfers e Elevator Ordering Of Device Queues Attempts to keep the drive heads moving in the same direction as long as possible to improve performance Assumes LBAs are physically sequentially ordered
47. a in each other s cache memory If one of the controllers fails or otherwise becomes non operational the surviving controller takes over its responsibilities with no loss of data Note This section presents only a brief introduction to External RAID Controller operation For additional details consult the hardware installation guide for the particular controller of interest LUN Mapping Overview External RAID Controller LUN Mapping allows logical drives or system drives to be made available or unavailable on one or more host ports The mapping is performed by assigning Logical Unit Numbers LUNs to logical drives The LUN assignments are per host port and are independent of the assignments on other host ports Logical drives may be assigned only one LUN per host port By not assigning a LUN to a logical drive on a particular host port that logical drive is made inaccessible to that host port Manual No 771961 4 53 External RAID Controller Operation Overview Host to LUN Mapping Overview The Host to LUN Mapping feature restricts host access to configured logical drives Access to a configured logical drive is granted only to a single host or group of hosts providing limited security control of data in a Storage Area Network SAN environment where multiple hosts are connected to the controller The Host to LUN mapping feature is intended for use in configurations in which multiple host computers attach to one or more My
48. able identifies a host and each column identifies a logical drive An X in the table connects a host with a logical drive A means the host is not connected The connections are toggled by left clicking the mouse on the entry As entries change in the Host to Logical Drive Mapping list the Logical Drive to LUN Mapping information is updated The following rules are enforced e Logical drives may share LUNs as long as the same host does not access both logical drives e The host to logical drive mapping can be made before assigning a LUN to the logical drive A LUN assignment can be made at any time Only valid LUN assignments are displayed in the LUN selection field 4 58 GAM Client v2 30 and WSAM User s Manual Configuration e Host to logical drive mapping may be done without assigning any hosts Hosts may be assigned at any time Set Sequential The Set Sequential button sets all logical drives to LUN assignments sequentially and all host to logical drive mapping to Enable All Hosts For example logical drive 0 to LUN 0 logical drive 1 to LUN 1 etc Clear All The Clear All button sets all LUN assignments to None You can then select individual assignments more closely while allowing several assignments of inaccessible WARNING DO NOT leave all assignments at None This indicates that no logical drives are accessible to any port on any controller Restore The Restore button resets the Host to LUN
49. an be in one of five states READY ONLINE STANDBY DEAD or REBUILD The controller stores the state of the attached drives in its non volatile memory This information is retained even after power off Hence if a disk drive is labeled DEAD in one session it will stay in the DEAD state until a change is made either by using a system level utility or after a rebuild Each of the states is described below Ready A disk drive is in a ready state if it Is powered on and Is available to be configured during the current session but remains unconfigured Manual No 771961 G 7 Glossary Note Ready State does not apply for Mylex External RAID Controllers Online A disk drive is in an online state if it Is powered on and Has been defined as a member of a drive group and Is operating properly Standby A disk drive is in a standby state if it Is powered on and Is able to operate properly and Was NOT defined as part of any drive group Dead A disk drive is in a dead state if it Is not present or If it is present but not powered on or If it failed to operate properly and was killed by the controller When the controller detects a failure on a disk it kills that disk by changing its state to dead A drive in a dead state does not participate in any I O activity No commands are issued to dead drives Rebuild A disk drive is in a rebuild state Whil
50. ancelled Logical drive initialization started Logical drive initialization done Logical drive initialization cancelled A new logical drive has been created A logical drive has been deleted Expand Capacity Started Expand Capacity Completed Bad Blocks found System drive size changed System drive type changed Fan has been restored No Message Power supply has been restored No Message Normal temperature has been restored No Message StorageWorks enclosure reported normal state GAM Server Software Started Successfully Controller is found Battery Backup Unit Present Battery Power OK Controller powered on Controller is online GAM Client v2 30 and WSAM User s Manual 400 A BBU reconditioning is started 401 BBU reconditioning is finished 402 BBU reconditioning is canceled 516 Server alive Physical Disk Drive Failure Codes 00 NoCause 01 WrtRecov01 02 WrtRecov02 03 WrtRecov03 04 WrtRecov04 05 WrtRecov05 06 WrtRecov06 07 WrtRecov07 08 WrtRecov08 09 WrtRecov09 0A WrtRecov 10 O0B WrtRecov11 0C WrtRecov12 0D WrtRecov13 OE WrtRecov14 OF WrtRecov15 10 WrtRecov16 11 WrtRecov17 12 WrtRecov18 13 WrtRecov19 20 StartDev01 21 StartDev02 22 StartDev03 Manual No 771961 No error code or drive not DEAD Write recovery failed Write recovery failed Write recovery failed Write recovery failed Write recovery failed Write recovery failed
51. ark In this case all information is presented as if there is a single enclosure with all the fans power supplies etc GAM Client v2 30 and WSAM User s Manual Monitoring Details Page Information Details Enclosure Status Acc Fans Power_ Temperature Alarm UPS Enor l ECER 0 Critical Critical OOKHigh OOK OOK235C0 T OOK OOKAC 1OKHigh 10K 2Absent 2 Absent RER 1 Failed Lost Absent OAbsent O Absent Absent O Absent 1OKLow 10K 1 Failed 10K 10K 2Faled 2Failed 20K 9C 2Failed 2 Failed 3 OK Low 3OKAC 40K DC 5 OK Low Fa gt Figure 5 21 SES Enclosure Information Details Page Enclosure Information Details page Figure 5 21 displays the following about the currently available Fibre enclosures e The status of each enclosure identified by an icon and an enclosure number as well as one of the following expressed in text e OK All components are optimal e Critical Some component has failed one more failure may result in data loss e Failed A failure has occurred that may result in data loss e The access status of each enclosure which indicates the controller s ability to communicate with the enclosure The status values are e OK Access is optimal e Critical Only one access path remains of the several that were detected previously If the last access path is lost the controller will take steps to protect the data e Lost The enclosure is unreachable by th
52. ation Since the problem has been resolved no error is reported to the system When a disk reports a media error during a write the controller issues a reassign command to the disk and writes the data out to a new location on the disk Drive Groups or Drive Packs A drive group is a group of individual disk drives preferably identical that are logically tied to each other and are addressed as a single unit In some cases this may be called a drive pack when referring to just the physical devices Up to eight 8 drives can be configured together as one drive group All the physical devices in a drive group should have the same size otherwise each of the disks in the group will effectively have the capacity of the smallest member The total size of the drive group will be the size of the smallest disk in the group multiplied by the number of disks in the group For example if you have 4 disks of 400MB each and 1 disk of 200MB ina pack the effective capacity available for use is only 1OOOMB 4 200 not 1800MB Dual Active Duplex Mode A method of interconnecting multiple RAID controllers that share a common set of drives In addition to increasing overall performance this method allows a surviving controller to take over resources of a failed controller This failover process is transparent to the host Duplex Mode See Dual Active Duplex Mode Error Table See Bad Block Table or Bad Data Table
53. ax are registered trademarks of Microsoft Corp Other names that are trademarks may be used herein for the purpose of identifying the products or services of their respective owners Unless otherwise noted companies names and data used in examples herein are fictitious Our Policy Although reasonable efforts have been made to assure the accuracy of the information contained herein this publication could include technical inaccuracies or typographical errors Mylex Corporation expressly disclaims liability for any error in this information and for damages whether direct indirect special exemplary consequential or otherwise that may result from such error including but not limited to loss of profits resulting from the use or misuse of the manual or information contained therein even if Mylex Corporation has been advised of the possibility of such damages Any questions or comments regarding this document or its contents should be addressed to Mylex Corporation at the address shown on the cover The following paragraph does not apply to the United Kingdom or any country where such provisions are inconsistent with local law MYLEX CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties or the limitation or
54. ch GAM Client e If you want to launch Global Array Manager Client right after Setup click the box to check the Launch Global Array Manager Client now option e Click Finish to complete Setup Manual No 771961 2 9 Installation of Global Array Manager Client or Workstation Array Manager Workstation Array Manager Installation The Choose Destination Folder dialog box is displayed Figure 2 13 Choose Destination Folder Ea Setup will install Workstation Array Manager in the following folder To install to this folder click Next To install to a different folder click Browse and select another folder You can choose not to install Workstation Array Manager by clicking Cancel to exit Setup Destination Folder C Mylex Workstation Array Manager Browse Figure 2 13 Destination Folder for Workstation Array Manager 1 In the Destination Folder area in Figure 2 13 the suggested directory path for installation of WSAM reads C Program Files Mylex Workstation Array Manager e To select a different destination folder click Browse navigate to the folder you wish to select then accept it e To proceed with the installation click Next If Setup detects a previous installation of Workstation Array Manager in the folder you specified you will see the following message Figure 2 14 2 10 GAM Client v2 30 and WSAM User s Manual Installation Question Setup has detected a prev
55. che policy write through WT or write back WB e Desired usable logical drive size in MB e Number of hot spare drives Multipliers can be added as part of the logical drive configuration to indicate replication of the logical drive definition on the same set of drives If the autoconfig dat file is not found the Global Array Manager will notify the administrator with an error window and then ask if the administrator would like the Global Array Manger to create an example file The example file will be the default file created at the time of the client installation 4 36 GAM Client v2 30 and WSAM User s Manual Configuration Automatic Configuration New Configuration flick Controller O 1 Welcome 2Finish RAID Assist has completed the configuration You can view details of the configuration by clicking the Details button IF you are satisfied with the configuration as defined below click the Apply button to implement the configuration If you wish to redefine the configuration go to the Welcome page and select Manual Configuration Configuration Summary Physical drives Bes Logical drives 1 Physical capacity 121450MB Logical capacity 86750MB Hot spares el Figure 4 31 Automatic Configuration gt New Configuration gt Finish The Finish screen appears Figure 4 31 Do the following 1 Examine the Configuration Summary for details about the conf
56. controller deleting the previous configuration and data if any e Add Logical Drive Sets up additional arrays logical drives leaving the existing array s intact At least one array must be configured on this controller and unconfigured drive space must remain e Expand Array Restripes data in your array across additional unconfigured drives to expand the capacity of the array Open New Configuration for example as shown in Figure 4 33 Assisted Configuration 2 x m Data Overwrite Method Create a new configuration If there is an existing configuration it New Configuration will be overwritten and all data will be lost m Data Retain Method Utilize the remaining available space in an existing array or create a new array using unconfigured disk drives Existing data will not be affected by this process Expand the capacity of an existing array Existing data will not be affected by this process Expand Aray Cancel Figure 4 33 Select New Configuration Manual No 771961 4 39 Running RAID Assist Assisted Configuration walks you step by step through a new configuration Figure 4 34 Each tab in the Assisted Configuration dialog box collects information about an important aspect of the configuration you wish to set up During this process you provide answers to several questions Fault Tolerance Tab Figure 4 34 1 Do you want Fault Tolerance Yes No 2 Do
57. d block and request sense data generated as a result of finding areas of damage or data unavailability on a storage device Data for all storage devices on the selected controller are presented in the same tables GAM Client v2 30 and WSAM User s Manual Startup amp Navigation Administration Menu Administration Sign On Define Server Groups Select Current Server Group Ctrl G Select Current Controller Ctrl C Raid Assist Initialize Logical Drives Controller Information Enclosure Information Controller Options Intelligent BBU Scan Devices Advanced Functions Settings Figure 3 6 Administration Menu The Administration menu Figure 3 6 contains the following options e Sign On Enables use of GAM s or WSAM s configuration and administration functions to Administrators gamroot password Enables only monitoring functions to Users Define Server Groups GAM Client only Sets up server groups and individual server names or IP addresses within each group e Select Current Server Group Ctrl G GAM Client only Displays the current contents of the server selection box located in the Global Array Manager window Functions in the same way as directly selecting the server selection box e Select Current Controller Ctrl C Displays the current contents of the controller selection box located in the Global Array Manager or Workstation Array Manag
58. d restart Failed to start after writing new configuration Bus scan selection timeout Bus scan max check conditions exceeded Device insertion failed to spin device Device insertion system drive went offline Unconfigured device failed inquiry Unconfigured device found Unconfigured device found Device COD ID does not match selected COD ID Device COD ID does not match selected COD ID Drive roaming dead device moved GAM Client v2 30 and WSAM User s Manual 7A DevRoamFail 7B DevRaomRplcd 7C ScanIngFail 80 RbIdOffline 81 RbldTooSmall 82 RbldFailed 83 RbldTerminated 84 RbldOffline02 AO NoSpareTrack Manual No 771961 Error Codes Drive roaming failed Drive roaming replaced drive Bus scan inquiry failed System drive went offline during rebuild start Drive too small for rebuilding Rebuild failed and drive not already marked DEAD Rebuild terminated move rebuilding drive to DEAD System drive went offline during rebuild start Drive reported 04 32 00 sense no spares available A 7 Physical Disk Drive Failure Codes GAM Client v2 30 and WSAM User s Manual Glossary Active Active Mode See Dual Active Duplex Mode BBU See Battery Backup Unit Bad Block Table or Bad Data Table There are two bad block tables that the controller automatically maintains The Rebuild Bad Block Table stores information on bad blocks encountered during a rebuild or consiste
59. desire OR If you want to add to an already built string select the string in the display box select additional devices under Device Selection and click the Add To button If you change the Operation Color or Line and click Add To the new selection replaces the previous one To delete analysis strings e Select a string in the display box and click Delete OR 5 28 GAM Client v2 30 and WSAM User s Manual Monitoring Click Delete All to delete all defined analysis strings To set the Sample Period e Type a number of seconds in the Sample Period box A data point will be created for display each Sample Period number of seconds To save all your settings to a file for future use 1 Click Save Settings A Save As dialog box is displayed Figure 5 24 Save As 1 1x Savei 5 34 Floppy A q4 E a E File name settingi Save as type GAM Settings Files gsf z Cancel Figure 5 24 Save Settings to a File 2 Enter a destination and filename for your settings file 3 Click Save To use previously saved settings 1 Click Open Settings An Open dialog box is displayed Figure 5 25 Open i 1x Lookin 9 3 Floppy A gt amp el File name settingl gsf Files of type cam Settings Files gsf x Cancel Figure 5 25 Open Previously Saved Settings Manual No 771961 5 29 Performance Monitoring 2 Enter a destination and select the settings file you wish to open 3
60. ding the code that is currently stored in the BIOS of your selected controller This information is helpful for diagnostic and troubleshooting purposes as well as to determine whether you need to upgrade some aspect of the firmware BIOS etc To do a flash upgrade 1 Type the name of the appropriate image file IMG in the Flash file selection box or click the Browse button to locate the file If you select Browse the Open Image file dialog box is displayed as shown in Figure 6 5 Lookin 2 34 Floppy A 1 6 aE a File name Bouima Files of type Controller firmware image files ima 7 Cancel Figure 6 5 Open Image File Dialog Box 2 Select the image filename using the file selection dialog box 3 Click Open Once you ve specified an appropriate image file the Start Flash button becomes available in the Flash Utility dialog box and the Flash file selection area displays details regarding the IMG file Figure 6 6 6 6 GAM Client v2 30 and WSAM User s Manual Maintenance Processes Flash Utility 24 x m Flash file selection Jane cu img ImageType BCU File Info Ver 4 78 08 Released on Aug 04 1998 EncodingFormat Zipped MajorVersion 4 MinorVersion 78 TurnNumber 0 BuildNumber 8 Current RAM information Record Type Version Build Time Flash Time Image Size BootBlock 4 04 28 02 30 1998 02 31 1998 16384 Firmware 4 05 27 04 01 1998 04 04 1998 229376 Rins 41n n
61. ds are Asynchronous 5 MHz 8 MHz 10 MHz 20 MHz and 40 MHz LVD only SCSI Tag Queuing Enable in order to queue up commands to be executed by the target e Enable by checking or disable by unchecking the following Clustering Parameter Clustering Under Windows NT 4 0 allows redundancy among controllers in various servers If a controller or server fails another controller can take over the disk drives and disk arrays that were formerly handled by the failed controller This mechanism imparts a fault tolerance among controllers and servers e Change the following Clustering Parameter Controller Host ID Change if you want to set this controller s target ID to something other than 7 Click the OK button to accept the changes or the Cancel button to delete them 4 22 GAM Client v2 30 and WSAM User s Manual Configuration Mylex External RAID Controllers Controller Options 121 x Global Parameters _____ SCS Parameters Channel jo 7 C 165i 8Bt C Asynchronous 5MHz omnts eommand C 8 MHz C 10 MHz D Enable Backoraund Intelizetion C 20 MHz C 40 MHz Rebuild Rate sp 4 r men a an Transfer Speed 5 MB s m Startup Parameters genan automatic z Devices Between Spins eo H Clustering Parameters Initial Delay 6 sec Je Enable Clustering Sequential Delay 10 sec Controller Hast Fibre Advanced Cancel Figure 4 23 Controll
62. e 2 Disk Arrays 3 Logical Drives Drive Logical RAID Capacity MB Capacity Write Init Stripe Cache No Drives Level Logical Physical Utilization Cache Drive Size Size New Rese Pano m fez fezos fie oF e peg fee o B frans z 4136 6204 jez V Fr j2 7 2e Delete Drive Clear All Apply Cancel Figure 4 44 Manual Configuration Logical Drives The Logical Drives tab in Manual Configuration is where you configure your disk arrays into logical drives Your first logical drive will set the stripe size and cache line size for all logical drives on this controller Do the following 1 Select a RAID level for your first logical drive Supported RAID levels are RAID 0 RAID 1 RAID 3 RAID 5 RAID 0 1 and stand alone drive JBOD Only RAID levels compatible with the current configuration will be available in the list 2 Enter the amount of available logical or physical capacity for this logical drive If your total configuration will have only one logical drive which uses all available capacity the default sizes should not be changed If you intend to create additional logical drives now or later enter a smaller number to reserve the desired amount of capacity 3 Check the Write Cache box if you want this logical drive to use Write Back caching This improves performance but puts data at risk You should have a battery backup unit or uninterruptable power supply if selecting this feature 4 50 GAM Client v
63. e Inquiry Data Vendor SEAGATE Product ST118202FC Revision 0007 Bus Width 1 Sync No Soft Reset No ANSI Version SCSI 2 Linked Yes CmdQue Yes Serial LK426771 r Device State Nego Transfer Speed 100 MB Sec Capacity 17366 MB Status Dead p Failure Indicator Nego Bus Width a Sector Size 512 Bytes 20 StartDev01 p Device Errors Soft Errors 0 Parity Errors 0 Hard Errors 0 Misc Errors 0 Rebuild Make Online Make Offline Close Figure 6 2 Rebuild Button Available for This Disk Device Manual No 771961 6 3 Running a Device Rebuild 3 Click the Rebuild button in the Disk Device Information dialog box Rebuild runs and the Rebuild Status box appears see the previous chapter Close the box and continue or leave the box open until Rebuild has completed When rebuild has completed the selected physical device AND the logical drive s of which it is a part are returned to operational status If you cancel rebuild the device returns to its offline dead status red X and the logical drives that occupy this physical device all go to critical status yellow exclamation point You must complete a future rebuild to return the physical device and logical drive s to operational status 1 Mylex External RAID Controllers perform rebuilds automati cally You need only click the Rebuild button to restart a stopped rebuild and only on slot 0 if duplex 6 4 GAM Client v2 30 and WSAM Use
64. e Monitor the power remaining in the Intelligent BBU e Request reconditioning of the Intelligent BBU External Controller BBUs e Set the low power threshold The Intelligent BBU s features and functionality are described in detail elsewhere GAM WSAM simply offer a way of keeping up to date as to the condition and charge in the battery GAM Client v2 30 and WSAM User s Manual Startup amp Navigation e Scan Devices Scans for new devices that have recently been added and are not currently identified within GAM Client or WSAM Advanced Functions Opens a submenu Figure 3 7 from which you can select the following options e Performance Analysis PCI Controllers Only Allows detailed analysis of disk level performance along several parameters Flash Utility Provides the ability to upgrade controller firmware as new firmware maintenance releases become available Shutdown External Controllers Only Enables clean shutdown of the controller system leaving the battery charged Scan Devices Advanced Functions Performance Analysis Settings Flash Utility Shutdown Figure 3 7 Advanced Functions Submenu e Settings Opens a tabbed dialog box in which you can specify the Alert Alarm Communication and Event Editor settings that you desire Examples of such settings include type of alarm such as pager fax email etc modem baud rate COM port stop bits data bits parity event severity level eve
65. e appears click OK then deselect Workstation Array Manager and click Next Manual No 771961 2 5 Installation of Global Array Manager Client or Workstation Array Manager Global Array Manager Client Installation If you ve selected Workstation Array Manager skip ahead to Workstation Array Manager Installation on page 2 10 The Choose Destination Folder dialog box is displayed Figure 2 7 Choose Destination Folder x oe will install Global Array Manager Client in the following older To install to this folder click Next To install to a different folder click Browse and select another folder You can choose not to install Global Array Manager Client by clicking Cancel to exit Setup Destination Folder C Mylex Global Array Manager Client Browse Figure 2 7 Destination Folder for Global Array Manager Client 1 In the Destination Folder area in Figure 2 7 the suggested directory path for installation of GAM Client reads C Program Files Mylex Global Array Manager Client e To select a different destination folder click Browse navigate to the folder you wish to select then accept it e To proceed with the installation click Next If Setup detects a previous installation of Global Array Manager Client in the folder you specified you will see the following message Figure 2 8 2 6 GAM Client v2 30 and WSAM User s Manual Installation Question Q Setu
66. e controller Any failures in the enclosure while this state exists will not be sensed by the controller Manual No 771961 5 23 Enclosure Monitoring and Management 5 24 The speed of the fans in the enclosure not shown for SAF TE enclosures Each fan is designated with a number The values are e Absent The fan is not installed or has failed in an undetectable way e OK The fan is optimal Fan speed is shown as either Stopped Low or High e Failed The fan is installed but has failed The status of the power supplies in the enclosure Each power supply is designated with a number The status values are e Absent The power supply is not installed or has failed in an undetectable way e OK The power supply is optimal e Failed The power supply is installed but has failed The status of the temperature sensors in the enclosure Each temperature sensor is designated with a number The status values are e Absent The temperature sensor is not installed or has failed in an undetectable way e OK The temperature sensor is optimal Two additional items are displayed with this state Celsius Temperature range for SES is 19 to 235 range for SAF TE is 10 to 245 Over Temperature Warning OT e Failed The temperature sensor is installed but has failed The status of the alarms or speakers in the enclosure Each alarm is designated with a number The status values are e Absent The alarm is
67. e it is in the process of being rebuilt During this process data is regenerated and written to the disk drive This state is sometimes referred to as Write Only WRO RAID RAID stands for Redundant Array of Independent Disks Several different forms of RAID implementation have been defined Each form is usually referred to as a RAID level The basic RAID levels supported by Mylex Disk Array Controllers are shown below G 8 GAM Client v2 30 and WSAM User s Manual Glossary The appropriate RAID level for a system is selected by the system manager or integrator This decision will be based on which of the following are to be emphasized Disk Capacity Data Availability redundancy or fault tolerance Disk Performance RAID Levels Mylex supports four RAID Advisory Board approved RAID levels RAID 0 RAID 1 RAID 3 RAID 5 and several special RAID levels RAID 0 1 RAID 00 RAID 10 RAID 30 RAID 50 and JBOD Level 0 Block striping across multiple drives is provided yielding higher performance than is possible with individual drives This level does not provide any redundancy Level 1 Drives are paired and mirrored All data is 100 duplicated on a drive of equivalent size Level 3 Data is striped across several physical drives Maintains parity information which can be used for data recovery Level 5 Data is striped across several physical drives For data redundancy drives are encoded
68. e made to correct them Consistency Check runs and the Consistency Check Status box appears see the previous chapter Close the box and continue or leave the box open until Consistency Check has completed 6 2 GAM Client v2 30 and WSAM User s Manual Maintenance Processes Running a Device Rebuild If a single device in a fault tolerant system fails the system is spared data loss by virtue of the striping with parity present across the logical drive RAID 3 RAID 5 or the total redundancy of data RAID 1 RAID 0 1 The failed drive needs to be replaced and the failed drive s data must be rebuilt on a new drive to restore the system to fault tolerance once again The device rebuild function performs this task A failed drive s data can be rebuilt to e The original drive if this drive happens to be still functional e A hot spare standby drive present for just this purpose or e A drive inserted in place of the failed drive If you need to carry out a device rebuild perform the following procedure 1 Reinsert the removed drive that caused the failure if it is still a good drive or replace the failed drive with a new drive of equal or greater capacity 2 Double click the relevant physical device in the Controller View window The Disk Device Information dialog box will open and the Rebuild button should be available Figure 6 2 Disk Device Information Channel Target Lun 0 r Devic
69. e satisfied with the Fax you ve set up click OK Your new Fax entry appears in the lower window of the Alarm Setup dialog box Refer back to Figure 4 13 for an example Remove a Fax 1 Select the Fax alarm type in the upper window of Alarm Setup 2 Select the Fax entry to remove in the lower window of Alarm Setup 3 Click Remove 4 At the confirmation message click Yes to remove the Fax entry or click Cancel to keep the entry Manual No 771961 4 13 Setting and Modifying User Preferences Add Email 1 Select the Email alarm type in the upper window of the Alarm Setup dialog box Figure 4 15 Bl address myserver com Launch Application Remove RIGBETIES Figure 4 15 Email Alarm Setup 2 Click Add The Email setup box is displayed as shown in Figure 4 16 Figure 4 16 Email Setup Dialog Box 3 In the Email box Enable or disable this Email entry using the Enabled check box e Enter the email address of someone who will receive an email 414 GAM Client v2 30 and WSAM User s Manual 4 Ds Configuration e Enter the subject of the email To test the email using the settings you ve input click Test When you are satisfied with the Email you ve set up click OK Your new Email entry appears in the lower window of the Alarm Setup dialog box Refer back to Figure 4 15 for an example Remove Email 1 2 3 4 Select the Email alarm type in the upper
70. e threshold to this new setting select Set Low Power Threshold then click Apply Recondition Battery To initiate a battery recondition sequence select Recondition Battery then click Apply The controller cache is placed in conservative cache mode Write Through while the battery s capacity remains below the determined threshold Discharge Battery Currently inactive Reserved for future use Fast Charge To initiate a fast charge on the battery select Fast Charge then click Apply A fast charge also occurs when the controller is powered on Stop Recondition Only enabled when a recondition process is underway To stop the recondition process select Stop Recondition then click Apply Apply Applies and saves the changes made in the BBU dialog box Cancel Exits the dialog box but does not stop the current action GAM Client v2 30 and WSAM User s Manual Chapter 6 Maintenance Processes Introduction Maintenance processes include the following activities which you may need to perform from time to time on arrays that use redundancy and or fault tolerance or to maintain the most up to date firmware maintenance releases e Running a consistency check on a logical drive to examine and optionally restore consistency parity Encountered errors may be written to the Error Table e Running a data rebuild on a physical drive that replaces a drive that went dead or offline e Upgrading Mylex PCI and External RAID Disk
71. ea taare aaaeeeaa aaea aa aa EE eaae OaE 4 33 Entering RAID ASSISt sigirning ir a aeai ariani 4 33 Automatic Configuration cceeceesceeeeeeeeeeeeeeeeeeeneeteeeeeeeeneeeee 4 35 Assisted Configuration eceesceeeceeeeeeeeeeseeeeeaeeeneetsaeeeeeeneeees 4 39 Manual Configuration ccceeceesceeeeeeeeeeeeeeeeeeseeeseeeeteeeneeeeaees 4 47 External RAID Controller Operation Overview s 4 53 LUN Mapping Overview cecceecceeeeeeeeeeeeeeeneeeeeeeeeesteeeeneeeaees 4 53 Host to LUN Mapping Overview ssssseeseeseeseeseeeriesesrrerrerreees 4 54 Host to LUN Mapping in Global Array Manager cee 4 55 Chapter 5 Monitoring IntrOdUCHION nieas i eee ec 5 1 Event Monitoring is ipea aeaa ea aaaea E pa raaa aitas 5 1 Opening the Log Information Viewer ssseseeeeeseeeereereeereeeen 5 2 Opening an Event Information WindOW ssssseeseeseeseeeeeeeeeeeeeeeeee 5 4 Controller Monitoring eeeeeeceeeeeeeeeeeseeteaeeeeeeenaeeeaeeseeeseaeeeeeeneeeeaeen 5 5 Opening the Controller View sssesseeeesseeseseeeieeieerneeeeneereeeneeneee 5 5 Displaying Controller Information eeeeeceeseeeeeeeeeeeeeeeeeeaees 5 10 Physical Device and Logical Drive Monitoring seee 5 13 vi GAM Client v2 30 and WSAM User s Manual Displaying Device Information eeeeseeeeseeeeeeneeteneeeeeneeeee 5 13 Viewing the Bad Block Table and Request Sense Data 5 16 Displaying Logical Drive Information 0 eee eerie
72. eeneeeaes 1 4 Requirements iing acl adeeb ead ere 1 5 GAM ar aa Me eee Bae ea ene te 1 5 TEST E E A eaten teaee ehcp seleeisnctaaies 1 5 Client and Workstation Hardware and Software ceee 1 5 Chapter 2 Installation Installation Overview eeeeceeeceseseeeeeeeseeteaeeeeeeteaeesaeeeeeteaeetsaeeeaeeeneee 2 1 Installation of Global Array Manager Client or Workstation Array Mana gofon ni ne satire h wid atte eee te eed 2 2 Files ISK esate eee et ah ie eA wei a Ad i as 2 2 Beginning the Installation and Selecting Components 2 2 Global Array Manager Client Installation 0 eeeeeeeeeeeeeeeeee 2 6 Workstation Array Manager Installation o e 2 10 Chapter 3 Startup amp Navigation Starting Global Array Manager or Workstation Array Manager 3 1 Server Component eeeeeceeeeeceeeeeeeeeseeeeaeeeaeeeneeeaeessaeeeaeeeeetaas 3 1 Client Component rsisi aineina o eiiiai sE Riata 3 1 Workstation Array Manager Component sessesseeseeseeeeeeeeeeeeeee 3 2 Navigating Global Array Manager Client or Workstation Array Manager ieira ast tink eit willed 3 2 Button Controls nnne ree e e eii a 3 2 Components of the GAM Opening Screen ssssssseeeeeeeeeeeeeeee 3 3 Components of the WSAM Opening Screen cceseeeeee 3 6 Menubar and Menus cceseececeeeceeseeceeseeeeeeseeeeesseeneneneneneees 3 8 Toolbar and Toolbar ICONS eeeeesseeeeseeeeeeeeeeeeeeeseneeeesnneereaes 3 14 Exiting Global A
73. eeteeeneeeeeeeeas 6 11 Appendix A Error Codes OVEIVieW Seismiskar aiseid alot ania ay A 1 Critical Level O 22 iahesi ca dainki ws bie aie All ediieinclae A 1 Serious Level i j e cccnes hatin cette ania A 1 Errors Level 2 rinier an teva Meh ain dari tated oa Sore dk A 2 Wanrnings Level 3 is ccc teeta tie iinet A 2 Information Level 4 i eeeeeecessceseeeeseeteaeeeaeeceeeeaeesseetsaeeneeeneeeeaees A 3 Physical Disk Drive Failure Codes ecceeseeeseeeeeeeeeeeeneeteeeeeeeneeteaee A 5 Glossary Manual No 771961 vii viii GAM Client v2 30 and WSAM User s Manual Chapter 1 Introduction Global Array Manager ofi x File View Administration Window Help al FE el a Pw Global Status View 204 32 130 202 192 9 10 55 NT EventID Severity Source Source Time DeviceAddress Description Seg Local Time For Help press F1 7 Figure 1 1 Global Array Manager Client Overview Global Array Manager Client software v2 30 GAM Client 2 30 is used in order to e Monitor manage maintain and configure Mylex Disk Array Controllers and the physical and logical drives that are connected to these controllers even across remote servers e Monitor and manage SCSI Host Bus Adapters and the physical devices that are connected to these adapters even across remote servers Manual No 771961 1 1 Overview Workstation Array Manager functions very similarly to Global Array Manager Client excep
74. en Global Array Manager Client starts Controller View Toggles the Controller View window showing channel ID target information and physical device logical drive configurations for the controller selected in the controller selection box Statistics View Toggles the Statistics View window display for the controller selected in the controller selection box Log Information Viewer Toggles the Log Information Viewer a window showing a log of recent system error and status event messages The Log Information Viewer opens by default when Global Array Manager Client or Workstation Array Manager starts Initialize Status Displays the progress percent complete of an ongoing full initialization of one or more drives Manual No 771961 3 9 Navigating Global Array Manager Client or Workstation Array Manager 3 10 Rebuild Status Displays the progress percent complete of an ongoing device rebuild Consistency Check Status Displays the progress percent complete of an ongoing logical drive consistency check Expand Capacity Status Displays the progress percent complete of an ongoing data restriping process across the target RAID group A Caution Once the Expand Array Expand Capacity process has begun you should not attempt to interrupt that process before completion Data loss will result You may however monitor the progress by choosing the Expand Capacity Status option Error Table PCI Only Displays a table of ba
75. en click OK at the confirmation message The Flash Utility writes the image data to RAM and resets the controller Because resetting the controller will suspend all I O activity currently underway on that controller a pop up is displayed which reads Initiating controller system reset Reset will take 30 seconds 6 10 GAM Client v2 30 and WSAM User s Manual Maintenance Processes Performing a Controller Shutdown Controller Shutdown is only performed with Mylex External RAID Controllers The purpose of this activity is to cleanly shut down the controller system leaving the BBU charged Open the Shutdown option as shown in Figure 6 11 Administration Shutdown Figure 6 11 Select Shutdown The Shutdown dialog box is displayed as shown in Figure 6 12 Shutdown Beton tolls otra Westie Figure 6 12 The Shutdown Dialog Box Manual No 771961 6 11 Performing a Controller Shutdown To perform a shutdown 1 Click Prepare for Shutdown Steps are taken to prepare for a clean controller shutdown including the following e switching to write through cache e draining the cache e electrically disconnecting the BBU e sending instructions to the partner controller to carry out the same actions Under Controller Status Preparing for Shutdown will be checked while the above steps are taking place 2 Click Refresh periodically to update status 3 When Ready to Power Off is checked under
76. en the controller is not fully started certain commands encounter a pause This turns off the pause Auto Restore Automatic Failback Default Disabled When enabled in a dual active controller system Automatic Failback allows automatic recovery of a partner controller when a replacement is inserted If you enable this option you must also enable the Controller Present Fault Signals option e Force Simplex Allows duplex firmware to work in a simplex environment by skipping some Active Active operations e Reset Propagation Allows a port that executes an internal reset to cause a reset event to occur on its attached interface e Multi port Reset Allows execution of an internal reset on a port only if a logical drive has been reserved through that port e Controller Present Fault Select DAC960SX only Default A Allows the user to select between two sets of backplane signals A or B to use when detecting the presence of a partner controller This option has no effect in a simplex environment e Controller Present Fault Signals Default Enabled Enables the use of backplane signals for sensing the presence of or possible fault in the partner controller in a dual active controller configuration If you have enabled Auto Restore Automatic Failback enable this function also This parameter is necessary for hot plugging controllers and automatic failback This parameter is not available through the LCD VT100 configuration utilit
77. ent make sure TCP IP is installed and functioning properly by running Ping software 2 Insert the distribution CD ROM into your CD ROM drive AutoRun will cause the CD ROM to display the Mylex RAID Management Software Installation menu Figure 2 1 Mylex Solutions xi x RAID Management Software Installation MOVING DATA SMARTER gt Read Documentation gt Install Global Array Manager gt Explore the CD gt Install Adobe Acrobat Reader Figure 2 1 Mylex RAID Management Software Installation Menu 2 2 GAM Client v2 30 and WSAM User s Manual Installation 3 Click on the option called Install Global Array Manager This option is used to install GAM Server GAM Client or WSAM Mylex RAID Management Software Setup loads the installation wizard Figure 2 2 Setup InstallShield Wizard which will guide you through the rest of the setup process Please wait E Mylex RAID Management Software Setup is preparing the Figure 2 2 Loading the Installation Wizard 4 After a few moments the Welcome dialog box appears Figure 2 3 Click Next to proceed with the installation or click Cancel to end the installation procedure and return to the menu Welcome x Welcome to the Mylex RAID Management Software Setup program This program will install Mylex RAID Management Software on your computer It is strongly recommended that you exit all Windows programs before running thi
78. er Options Dialog Box For External DAC In the Controller Options dialog box Figure 4 23 you have the option to do any of the following e Enable by checking or disable by unchecking any of the following Global Parameters e Automatic Rebuild Management Works in conjunction with SAF TE disk array enclosures to detect removal of a failed drive and perform an automatic rebuild after installation of a replacement drive Do not disable this unless you are sure of the consequences e Active Negation Not available for External RAID Controllers e Read Ahead Not available for External RAID Controllers e Disconnect On First Command Not available for External RAID Controllers e Background Initialization Not used on External RAID Controllers e Change the default Rebuild Rate to less than or equal to 50 A rate of 50 devotes the maximum allowable resources to a drive rebuild or array expansion allowing the Rebuild or Expand to proceed Manual No 771961 4 23 Setting and Modifying Controller Options at its fastest Lowering the number devotes more resources to I Os and consequently slows the Rebuild or Expand Array process e Change any of the following Startup Parameters e Spin up Change if you do not want automatic drive spin up Other choices are to spin up at power on or to wait for a command and then do an automatic drive spin up e Devices Between Spins Number of devices to spin up at one time A low number l
79. er window Functions in the same way as directly selecting the controller selection box Manual No 771961 3 11 Navigating Global Array Manager Client or Workstation Array Manager 3 12 RAID Assist Mylex s built in RAID Controller configuration utility Facilitates configuration tasks using either one step automatic configuration a configuration wizard assistant or a manual advanced level configuration option allowing more control over configuration parameters Initialize Logical Drives Offers the ability to run a full initialization of logical drives at a time of your choice NOT just immediately following a new configuration If it s inconvenient to follow a configuration immediately with a logical drive initialization you can decline the initialization and use this menu item to start the process at a later time Controller Information Displays key information about the currently selected controller Enclosure Information Displays SES and SAF TE Enclosure Management information for Mylex External Fibre Channel Controllers such as the DAC960FF Controller Options Sets various parameters for the selected Disk Array Controller or SCSI HBA Unlike Controller Information user definable controller parameters are modified in Controller Options Intelligent BBU Only enabled if the selected controller has an Intelligent Battery Backup Unit installed Displays a dialog box from which you can do the following
80. ere along the event line or double click in the Event ID field An event information window for your selected event is displayed An example is shown in Figure 5 3 EventID E 135 Severity 2 x SOURCE 204 32 130 202 DEVICE ADDRESS ctl 3logdrv 0 DESCRIPTION logical drive is critical CAUSE Could be one or more of the following One physical device failed REQUIRED ACTION eplace the physical device tart the rebuild if required Figure 5 3 Event Information Window A variety of information about the event is displayed to aid in your troubleshooting The Event ID and Severity Level are displayed in the window s titlebar SOURCE DEVICE ADDRESS and DESCRIPTION redisplay information available on the original event line 5 4 GAM Client v2 30 and WSAM User s Manual Monitoring The most useful fields are CAUSE Possible reasons that the event occurred and REQUIRED ACTION What you should do in response to this message Informational messages will most likely have no required actions Critical Serious Error and Warning messages may specify useful required actions 3 Click OK to close the event information window Controller Monitoring For GAM Client after a client and server connection is made through sign on the GAM Client opens a window for each RAID controller SCSI HBA and their drives operating in that file server These controller windows are the Global Array Manager Client s Contr
81. ers to the Boolean Exclusive OR operator In any RAID 3 or RAID 5 array the capacity allocated to redundancy is the equivalent of one drive SCSI Drive A disk drive equipped with a SCSI interface sometimes referred to as a SCSI Disk Each disk drive will be assigned a SCSI address or SCSI ID which is a number from 0 to 7 0 to 15 under Wide or Ultra SCSI The SCSI address uniquely identifies the drive on the SCSI bus or channel Session Refers to the period of time between any two consecutive system shutdowns System shutdown may be either a power off on or a hardware reset Simplex Mode See Single Controller Simplex Mode G 10 GAM Client v2 30 and WSAM User s Manual Glossary Single Controller Simplex Mode A single controller attached to a set of drives that offers RAID functionality without the controller fault tolerance inherent in dual active mode Standard Disk Drive This term refers to a hard disk drive with SCSI IDE or other interface that is attached to the host system through a standard disk controller Standby Replacement of Disks Hot Spare The Standby Replacement or Hot Spare is one of the most important features the controller provides to achieve automatic non stop service with a high degree of fault tolerance The rebuild operation will be carried out by the controller automatically when a disk drive fails and both of the following conditions are true e A
82. es mylex global array manager client gam2cl exe 22 Figure 2 10 Installation Progress Display Shortly after the installation completes the following display appears Figure 2 11 View Readme Files Eg You may now view additional information for the installed components to learn of any last minute additions or changes Figure 2 11 View ReadMe File s If you also installed Global Array Manager Server your screen will display the names of both readme files 2 8 GAM Client v2 30 and WSAM User s Manual Installation e To view changes and updates to the program or installation guide check the box which reads Read the Global Array Manager Client readme file now then click Next 4 If you chose to view the ReadMe file the Notepad accessory will open and the file will be presented Read the contents of this file for the most up to date information about Global Array Manager Client Much of this information may not appear in this installation guide as sometimes last minute modifications to the software are done after completion of the guide You may also wish to print the contents of this file 5 Close the Notepad accessory after reading and or printing 6 The Setup Complete dialog box displays Figure 2 12 Setup Complete Setup has finished installing the components and or sub components that you have requested Click Finish to complete Setup Figure 2 12 Setup Complete Laun
83. essens the likelihood of a power drain e Initial Delay Number of seconds to wait before spinning up the first disk set e Sequential Delay Number of seconds between consecutive device spin up cycles e Change any of the following SCSI Parameters note that Transfer Speed is not changeable e Channel selects the channel to be viewed for the current data e Whether the channel will negotiate 8 bit or 16 bit transfers e Maximum data transfer rate of the disk side channels Speeds are Asynchronous 5 MHz 8 MHz 10 MHz 20 MHz and 40 MHz LVD only Note SCSI Parameters are disabled for Fibre back end products such as the DAC960FF Note Clustering Parameters are not used on External RAID Controllers 4 24 GAM Client v2 30 and WSAM User s Manual Configuration Advanced Controller Options All External RAID Controllers Click the Advanced button in the Controller Options dialog box to inspect and or change additional External RAID Controller Options Advanced Controller Options 21x 1 230 64 244 Queue Limit feo ia g MAX IOPs Limit fi 50 Sm im I Enable Conservative Cache Mode V Enable Super Read Ahead SRA I Enable SAF TE Use OF UPS I Enable Restrict Reassign To One Block I Enable Smart Large Host Transfers IV Enable Elevator Ordering Of Device Queue T Enable Operational Fault Management M Enable Coalesce Device Queues M Disable Wide Transfer On Host M Enable True Verification Of Data M Enable
84. est users can monitor Global status and the Log Information Viewer They cannot make changes to any parameters or configurations User A User has ordinary system privileges A User signs on with his or her username and a password that has been assigned by the Administrator of that server A User can alter parameters of anything that is not controller or drive related and also monitor the status of any selected controller and RAID Manual No 771961 4 1 Signing On to a Server subsystem but has no administrative capability The User cannot set up or modify configurations kill drives rebuild drives or change their on line status In essence Users can look but they can t touch Administrator Individuals with Administrator security access have the capabilities of Guests and Users plus the ability to manipulate controllers and RAID subsystems These additional abilities include configuration drive kill drive rebuild and drive state changes An Administrator initially signs on as gamroot and secures his or her access with a password Under Windows NT the Global Array Manager uses security features built into Windows NT Signing On To gain access capabilities beyond Guest level you must sign on to a server If you double click a server from the Global Status View window when you are not already signed on then click on any option that requires Administrator rights the Sign On dialog box appears automatically
85. ew Toggles the Statistics View window for the currently selected DAC or HBA Error Table Displays a table of bad block and request sense data Sign On Enables configuration and administration functions to Administrators and monitoring functions to Users Settings Opens a dialog box for specifying the Alert Alarm Communication and Event Editor settings that you desire Help Displays the on line help contents page Exiting Global Array Manager or Workstation Array Manager Exiting GAM Client or WSAM Exit Global Array Manager Client or Workstation Array Manager as shown in Figure 3 11 Note Open Configuration Ctrl 0 Save Configuration Ctrl S Clear Configuration Ctrl Q Figure 3 11 Select Exit We recommend leaving the GAM Client running as long as there are servers you wish to monitor or configure If you do exit you will be unable to receive events from GAM Server and you will not be informed of errors or status unless you restart GAM Client and reconnect to the server s Manual No 771961 3 15 For More Information Exiting GAM Server Some operating systems such as NetWare allow you to unload the GAM Server component while the file server remains running Other operating systems may require you to down the file server in order to exit from or remove the GAM Server component A Caution Be aware that downing a file server may result in data loss i
86. ew tab Manual No 771961 5 35 Performance Monitoring Performance Analysis Note Performance Analysis is available only for Mylex PCI Disk Array Controllers Open the Performance Analysis as shown in Figure 5 31 Sign On Define Server Groups Select Current Server Group Ctri G Select Current Controller Ctrl C Raid Assist Initialize Logical Drives Controller Information Enclosure Information Controller Options Intelligent BBU Scan Devices ced Functions Perfo Flash Utility Shutdown Settings Figure 5 31 Select Performance Analysis Settings When you open Performance Analysis the Settings page is displayed Here you will define the controllers channels and target physical devices or logical drives to include for performance analysis You select an item and operation to analyze define a color and line segment to differentiate this analysis from others used for comparison and optionally save your settings and capture data to a file Figure 5 32 shows the Settings page 5 36 GAM Client v2 30 and WSAM User s Manual Monitoring Performance Analysis 204 32 130 200 x Settings History m Device Selection Device type Controller Channel Logical Drive e Physical Logical All 0 1 DAC960PD 1 Item CommandFinish s x Operation Read 7 T j Coo m fet Chr TotO Tatt Line gt Device
87. exclusion of liability for indirect special exemplary incidental or consequential damages in certain transactions therefore this statement may not apply to you Also you may have other rights which vary from jurisdiction to jurisdiction Information in this publication is subject to change without notice and does not represent a commitment on the part of Mylex Corporation Changes may be made periodically to the information herein these changes will be incorporated in new editions of the publication Mylex Corporation reserves the right to make improvements and or changes at any time in the product s and or program s described in this publication It is possible that this publication may contain reference to or information about Mylex Corporation products machines and programs programming or services that are not announced in your country Such references or information must not be construed to mean that Mylex Corporation intends to announce provide or make available such Mylex products programming or services in your jurisdiction About This Manual This installation guide covers the steps involved to install and use the client component of Mylex Corporation s Global Array Manager Version 2 30 or the Workstation Array Manager For information on installing and running the server component of Global Array Manager version 2 30 consult the Disk Array Controller Software Kit Installation Guide and User Manual Mylex Part Number
88. f I Os are in progress along the network Exit the GAM Server component only if necessary For More Information This concludes the Startup amp Navigation chapter For additional information on Global Array Manager or Workstation Array Manager options and functionality refer to other chapters in this installation guide AND to the context sensitive online help file available from the Help menu by pressing F1 or by right mouse clicking an item on which you require help 3 16 GAM Client v2 30 and WSAM User s Manual Chapter 4 Configuration Introduction Configuration activities involve the following e Setting up server groups and servers GAM Client only e Loading a configuration from disk and saving it to the controller e Setting or modifying user preferences such as alarms alerts event message editing and communications parameters e Setting or modifying controller options to suit your application needs e Creating modifying or deleting Mylex RAID Controller configurations e Mapping LUNs External RAID operation only Signing On to a Server Security Access Levels The ability to perform certain actions within the Global Array Manager Client depends on your security access level There are three levels of security access Guest no sign on User and Administrator Guest By attaching to a file server through the Global Array Manager Client a user is automatically assigned Guest no sign on status Gu
89. f a power failure or system crash during the time the data is only in the cache Write Through Cache Refers to a caching strategy whereby data is written to the drive before completion status is returned to the host OS This caching strategy is considered more secure since a power failure is less likely to cause loss of data However a write through cache results in a slightly lower performance Manual No 771961 G 13 Glossary G 14 GAM Client v2 30 and WSAM User s Manual fINYLEX MOVING DATA gt SMARTER Corporate Offices e 34551 Ardenwood Blvd Fremont CA 94555 3607 USA Tel 510 796 6100 e Sales Fax 510 745 8016 e www mylex com European Sales e P O Box 513 Great Missenden Bucks HP 16 OPG United Kingdom Tel 44 1344 302200 e Fax 44 1344 301100 e www mylex com
90. figuration If you wish to redefine the configuration go to Welcome page and select Manual Configuration Optimization Configuration Summary oe Physical dives 4 Logical dives 1 Physical capacity 12408MB Logicalcapacity 8272MB Hot spares Het RAID level RAIDS Stripe size BKB Cache line size 8KB Enable write cache No Initialize No lt Back Apply Cancel Figure 4 40 Assisted Configuration gt New Configuration gt Finish When you get to the Finish screen Figure 4 40 do the following 1 Examine the Configuration Summary for details about the configuration that RAID Assist will set up 2 If you want to start over click the Welcome tab or Cancel button OR If you want to change your answers to any of the questions you were asked click the appropriate tab to return to that screen OR If you want to view the configuration before it is applied to the controller click the Details button You will be taken to an equivalent of the Disk Arrays page as shown in Manual Configuration except that you can only view and close the details window 3 If you accept the configuration as presented click the Apply button at the Finish page to apply the new configuration to the controller A warning confirmation box appears as shown in Figure 4 41 4 46 GAM Client v2 30 and WSAM User s Manual Configuration WARNING x This process is data destructive If you want to p
91. file dialog box is displayed as shown in Figure 6 8 6 8 GAM Client v2 30 and WSAM User s Manual Maintenance Processes Lookin 2 34 Floppy amp gt amp el k E 3 41924hp ima Filename 41924hp ima Files of type Controler Firmware Image ima 7 Cancel Figure 6 8 Open Image File Dialog Box 2 Navigate to and select the image filename 3 Click Open Once you ve specified an appropriate image file the Apply button becomes available in the Flash Utility dialog box and the Flash file selection area displays details regarding the MA file Figure 6 9 Flash Utility x m Flash file selection fa 441924hp ima Firmware Image Information Target Controller SX Type 0 Version 4 19 Build 24 Misc 0x00000000 Debug 0x00000000 Date 073198 Time 142235 Apply Figure 6 9 Additional Flash File Information 4 Compare the information for the new MA with the current information to confirm that a flash is warranted for example that the IMA contains a newer version of code Manual No 771961 6 9 Using the Flash Utility 5 Click Apply Because flashing new code to the controller erases what was there previously confirmation is required to proceed with the flash Figure 6 10 WARNING x This process is data destructive If you want to proceed confirm by typing the word YES a ee Figure 6 10 WARNING Message for Flash 6 Type YES th
92. g Information Viewer is opened when the program is started and one or more controllers are detected as connected to the server s The viewer displays the contents of GAM2CL LOG an ASCII text file This file contains a chronological log of all the events that occur while this session of the program is executing GAM2CL LOG is the default name It may be changed in the INI file Should you need to open the Log Information Viewer manually do so as shown in Figure 5 1 v Global Status View Controller View Statistics View Log Information Viewer Initialize Status Rebuild Status Consistency Check Status Expand Capacity Status Error Table Figure 5 1 Select Log Information Viewer 5 2 GAM Client v2 30 and WSAM User s Manual Monitoring Log Information Viewer 0 Severity Source Source Time Device Address Description Seq Fri Sep 26 12 14 431 ctl 4 logdrw 1 System drive type changed Fri Sep 26 12 14 Fri Sep 26 12 13 14 1 ctl 4 logdry 1 Consistency check is finished Fri Sep 26 12 13 Fri Sep 26 12 12 46 1 ctl 4 logdrv 1 A Consistency check is started Fri Sep 26 12 12 Fri Sep 26 11 58 211 ctl 4logdryv 3 A new logical drive has been cre Fri Sep 26 11 58 Fri Sep 26 11 58 211 ctl 4 logdrv 2 A new logical drive has been cre Fri Sep 26 11 58 Fri Sep 26 11 58 211 ctl 4 logdrv 1 A new logical drive has been cre Fri Sep 26 11 58 H Figure 5 2 Log Inf
93. gical drive configured RAID level and logical drive status Note Dual active controllers External RAID Controller operation will show at target ID 6 AND 7 in each channel column This only appears if the selected controller is operating in duplex 5 6 GAM Client v2 30 and WSAM User s Manual Monitoring Fibre to Fibre RAID Controllers EJ Controller View 192 9 10 170 Controller 0 administrator Physical Devices MB Logical Drives MB Channel 0 Channel 1 Channel 2 Channel 3 994 RAID 5 E 994 RAIDS 994 RAID 1000 RAIDS o 1 2 3 4 1000 RAIDS 5 6 1000 RAID3 1000 RAIDS E 1000 RAID Total Logical Capacity 7982 MB Total Physical Capacity 138928 MB E Enclosure Figure 5 6 Controller View Window Fibre RAID Controller The Controller View window Figure 5 6 displays the following information about the controller currently selected in the controller selection box The number of channels on this controller each channel depicted as a tower The physical devices present on each channel specifying the target ID capacity of the device device type and device status The logical drives configured on the controller specifying the logical drive number capacity of the logical drive configured RAID level and logical drive status An Enclosure button which is used to monitor SES SAF TE data pertinent to the Fibre Channel RAID Controller enclosure See Enclosure
94. hat the data on both drives of the mirrored pair is exactly the same For RAID Level 5 redundancy a consistency connect is a function that allows a target device typically a disk drive that received a request to perform a relatively long I O operation to release the bus so that the controller can send commands to other devices When the operation is complete and the bus is needed by the disconnected target again it is reconnected Disk Failure Detection The controller automatically detects disk failures A monitoring process running on the controller checks among other things elapsed time on all commands issued to disks A time out causes the disk to be reset and the command to be retried If the command times out again the disk could be killed taken offline by the controller its state changed to dead Disk Media Error Management Mylex Disk Array Controllers transparently manage disk media errors Disks are programmed to report errors even ECC recoverable errors When a disk reports a media error during a read the controller reads the data from the mirror RAID 1 or 0 1 or computes the data from the other blocks RAID 3 RAID 5 and writes the data back to the disk that encountered the G 2 GAM Client v2 30 and WSAM User s Manual Glossary error If the write fails media error on write the controller issues a reassign command to the disk and then writes the data to a new loc
95. he and use write through caching If the Consistency Check button is enabled you may manually run a consistency check on this logical drive as discussed in the next chapter Click Show Bad Data Blocks to display a window of all bad data blocks found on this logical drive If the logical drive has been placed offline due to some external cause such as a power failure effecting an enclosure click on the Force On Line button to return the logical drive to an active state A warning window appears asking for confirmation of the force on line procedure A Caution Forcing a logical drive on line should only be done in a power failure recovery situation Doing so at any other time may result in data loss Click the Close button to close the dialog box Manual No 771961 5 19 Enclosure Monitoring and Management Enclosure Monitoring and Management SCSI Enclosures Among the stack of drives displayed in a channel tower of the Controller View window you may find a cabinet processor depicted Its icon looks something like this am Double click the cabinet processor icon to display enclosure information about the cabinet processor Processor Device Information Channel 0 Target 6 Lun 0 Device Inquiry Data Vendor SDI Product RAIDPro Revision 1 04 Bus idth 8 Bits Narrow Syne No Soft Reset No ANSI Version SCSI 2 Linked No CmdQue No Device State Transfer Speed ASYNC BusVVidth 8
96. he name IP address identifying the HBA A right mouse click on the server will toggle through the name IP address and WWN of the HBA The host states are defined as e Not Connected This is a valid host not logged on to the loop e Connected tThe host is logged on to the fibre channel loop The host cannot be found on the IP network The WWN of the host HBA is displayed on the network Manual No 771961 4 57 External RAID Controller Operation Overview e Found tThe lost is logged on and found The IP address or host name is displayed A server may have more than one Available hosts on the network are determined from the following e The list of servers defined in the server groups for the client All duplicates are eliminated Note For a server to be found on the network it must be defined in a server group on the GAM client The server must be running the GAM server driver software e A connection to the server is attempted e For each controller on this server send the magic command The WWN of the host the controller and partner controller are returned e An association between the IP address and the host WWN is made This information is used to construct the host list Note This determination process can take a long time This operation is performed the first time the Host to LUN Mapping page is entered This operation is not repeated unless the Refresh Hosts button is activated Each row in the t
97. he Pager alarm type in the upper window of Alarm Setup 2 Select the Pager entry to remove in the lower window of Alarm Setup 3 Click Remove A confirmation message is displayed as shown in Figure 4 12 Global Array Manager G 555 1234 will be deleted Do you want to proceed Yes Figure 4 12 Remove Pager Entry Message 4 Click Yes to remove the Pager entry or click Cancel to keep the entry Manual No 771961 4 11 Setting and Modifying User Preferences Add a Fax 1 Select the Fax alarm type in the upper window of the Alarm Setup dialog box Figure 4 13 Launch Application Microsoft At Work Fax Figure 4 13 Fax Alarm Setup 2 Click Add The Fax setup box is displayed as shown in Figure 4 14 Figure 4 14 Fax Setup Dialog Box 3 In the Fax box e Enable or disable this Fax entry using the Enabled check box 4120 GAM Client v2 30 and WSAM User s Manual Configuration e Enter the fax phone number of someone who will receive a fax e Enter a fax header if desired Note For fax notification Microsoft Exchange and Microsoft At Work Fax software must be installed on your system GAM supports only Microsoft At Work Fax under Windows 95 The Software field is not selectable The required fax software components should already be available as part of the normal Windows 95 installation 4 To test the fax using the settings you ve input click Test 5 When you ar
98. iguration that RAID Assist will set up 2 If you want to start over click the Back or Cancel button or the Welcome tab OR If you want to view the configuration before it is applied to the controller click the Details button You will be taken to an equivalent of the Disk Arrays page as shown in Manual Configuration except that you can only view and close the details window 3 If you accept the configuration as presented click the Apply button at the Finish page to apply the new configuration to the controller A warning confirmation box appears as shown in Figure 4 32 Manual No 771961 4 37 Running RAID Assist WARNING x This process is data destructive If you want to proceed confirm by typing the word YES a ee Figure 4 32 WARNING Before Applying the Configuration 4 Type YES and click OK if you are sure you want to apply the new configuration and overwrite the old If you re not sure click Cancel Note In Automatic Configuration Add Logical Drive and Expand Array function very similarly to the New Configuration option except that they do not use the autoconfig dat file In each case RAID Assist prepares an optimal configuration without user input based on characteristics of the available devices 4 38 GAM Client v2 30 and WSAM User s Manual Configuration Assisted Configuration Assisted Configuration provides three options e New Configuration Sets up a new configuration on the
99. ine Graph Pie Graph Bar Graph o 1 2 3 4 6 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 26 Visible Y multiplier Y offset Y autoscale Value Yes 1 0 0 Yes 63 66 Yes 1 0 0 Yes 7 65 Device Operation 0 CtlO Chn Tgt0 Tote Reads CtO Chn Tatl Tat Reads Time Scale Unit H Graph Data g sec Apply C Past Present Pause Graph Wptiors Figure 5 37 Performance Analysis History Display The History page displays data for the analysis strings specified in the display window in the form of lines generated on a grid with time units along the horizontal axis and percentage along the vertical axis To set the Time Scale Unit 1 Enter a number of milliseconds in the text box 2 Click Apply Each horizontal grid mark s value for example from 0 to 1 1 to 2 etc will equal the number of milliseconds you ve specified The Graph Data box allows you to see currently generated data from the selected server Present or previously saved data Past from the buffer or from a data file selected within the Settings page 5 42 GAM Client v2 30 and WSAM User s Manual Monitoring To change Graph Options for a particular analysis string 1 Select the analysis string of interest in the display window 2 Click Graph Options You can change whether this string s data will be visible whether the data will autoscale along the Y axis the Y axis mul
100. ined parameters and asks the user questions to gather the key information necessary to build the array If configuration needs go beyond what Auto or Assisted Configuration offers the Manual Configuration option allows additional control over logical drive setup parameters including LUN Mapping for External RAID Controllers Entering RAID Assist Open RAID Assist as shown in Figure 4 28 Sign On Define Server Groups Select Current Server Group Ctr G Select Current Controller Ctrl C Raid Assist Initialize Logical Drives Controller Information Enclosure Information Controller Options Intelligent BBU Scan Devices Advanced Functions gt Settings Figure 4 28 Select RAID Assist Manual No 771961 4 33 Running RAID Assist Raid Assist 204 32 130 202 Controller 2 1 Welcome Welcome to RAID Assist RAID Assist allows you to set up new configurations add logical drives to existing configurations and expand the capacity of existing arrays To get started with RAID Assist choose a configuration method below Creates an optimal configuration using all available drives with minimal user input Creates or modifies a configuration using a 5 step by step question and answer format Assisted Configuration Creates or modifies a configuration using only z infomation provided by the user Manal Conran Cancel Figure 4 29 RAID Assist
101. ins the following e Low Power Threshold A preset or modifiable power level expressed as hours or minutes of charge used to trigger an alarm when the battery power level drops below the set value Set a threshold select Set Low Power Threshold under Actions then click Apply to set the new value e Current Power The current power level of the battery expressed as hours or minutes of charge This value will change as the battery is discharged or charged 5 50 GAM Client v2 30 and WSAM User s Manual Monitoring e Maximum Power The highest level the battery has been charged up to expressed as hours or minutes of charge This value will change as the battery ages and is reconditioned The older the battery gets the less charge it can contain e 9 Charge Level The battery s charge level where 100 means the battery has been charged up to its maximum level e Display Minutes Displays power values in minutes e Display Hours Displays power values in hours and tenths of hours e Refresh Updates the Power Levels and Battery Status groups It is useful during a lengthy operation such as a recondition to update the dialog without leaving it and re entering Battery Status The Battery Status area of the Intelligent Battery Backup Unit dialog box contains the following e Battery Type The battery pack type Available options are Ni Cad or Unknown e Version Version number for the controller Version selection numbers a
102. ious installation of this product in the specified folder Do you want to overwrite the previous installation Figure 2 14 Existing WSAM Detected Overwrite e If this message appears click Yes to overwrite the existing WSAM installation OR e Click No to retain the existing WSAM and select a new destination folder for the new WSAM then click Next to proceed 2 The Installation Summary screen Figure 2 15 summarizes the components and subcomponents you ve selected for installation Click Next to continue or Back to change selected components Installation Summary When you click Next the following actions will be taken Global Array Manager Client Program Files lt Will not be installed gt Global Array Manager Server Program Files lt Will not be installed gt Driver lt Will not be installed gt DMI Files lt Will not be copied gt SNMP Files lt Wwill not be installed gt Workstation Array Manager Program Files Will be installed into folder C Program Files Mylex Workstation Array Manager Driver Will be installed into folder A Cancel CAWINNTASystem32 DRIVERS gamdry sys Figure 2 15 Installation Summary Manual No 771961 Installation of Global Array Manager Client or Workstation Array Manager 3 During installation files are decompressed and copied from the installation CD ROM to the destination folder Figure 2 16 Copying Workstation Array
103. l Array Manager Client or Workstation Array Manager Components of the Global Array Manager Window The major components of the Global Array Manager window Figure 3 1 are described below 1 Item 1 is the GAM Client menubar There are five menus with several selections each The contents of the menus and the functionality of several of the most important selections will be described throughout this guide Item 2 is the GAM Client toolbar There are eight toolbar icons representing eight of the most useful functions available in GAM Client The identity of each toolbar icon and an explanation of the purpose of each will be described in later sections of this chapter Item 3 is the GAM Client server selection box When selected the box displays the names of each server group that is in contact with the current client workstation Each group may consist of multiple servers You may select a specific server group to view or select All Servers if you want to view all the servers that are connected to this workstation Item 4 is the GAM Client controller selection box When selected the box displays the controller ID C 0 C 1 etc and controller type BT 952 DAC960PJ etc of each SCSI HBA and PCI SCSI or External RAID Controller connected to the currently selected server For External RAID Controller duplex pairs a double pointed white arrow connects the controller pair selections Components of the Global Status View Wi
104. lex Default All e Click the Default All button to reset all events of all severity levels back to their Mylex defaults Finish by doing one of the following e Click OK to accept the event settings and exit the Settings dialog box or Click Cancel to leave original settings unchanged or Click another Settings tab to set additional user preferences Manual No 771961 4 19 Setting and Modifying Controller Options Setting and Modifying Controller Options Open Controller Options as shown in Figure 4 21 Controller Options Figure 4 21 Select Controller Options Mylex PCI RAID Controllers Controller Options kal k m m m EE T ay conch Figure 4 22 Controller Options Dialog Box For PCI DAC 4 20 GAM Client v2 30 and WSAM User s Manual Configuration Note You can not change controller options if the controller is running Mylex PCI firmware version 3 x or below In the Controller Options dialog box Figure 4 22 you have the option to do any of the following e Enable by checking or disable by unchecking any of the following Global Parameters Automatic Rebuild Management Works in conjunction with SAF TE disk array enclosures to detect removal of a failed drive and perform an automatic rebuild after installation of a replacement drive Active Negation Recommended for cleaner SCSI signal transitions Read Ahead Reads data to the next stripe boundary based on st
105. lex controllers This is also referred to as a Storage Area Network SAN configuration The host computers are attached to the controller s through a fibre channel arbitrated loop or through a switch making the logical drive accessible to all host computers By utilizing host to LUN mapping each logical drive can be configured to be visible to a single host computer only The controller uses the World Wide Name WWN to uniquely identify host computers that have logged into the controller A list of valid hosts and their corresponding WWNs is provided to GAM in order to configure the host to LUN mapping Once logical drives are configured the controller maintains a table of WWNs for each logical drive This table defines the hosts that are granted access to each logical drive and the controller port and the LUN number 4 54 GAM Client v2 30 and WSAM User s Manual Configuration Host to LUN Mapping in Global Array Manager Global Array Manager implements Host to LUN Mapping by allowing the user to select the topology used by the controller s the port to be used the Host to Logical Drive Mapping for each logical drive and the Logical Drive to LUN Mapping for each logical drive Figure 4 46 shows an example of Host to LUN mapping Manual Configuralion Edit Configuration 192 9 10 156 Controller 0 1 Weleome 2 Disk Arrays 3 Logical Drives 4 un Wapping r Topology Por Selection Logical Drive to LUN Mapping finactive Fort
106. ll logical drives For individual logical drives make sure All is not highlighted At the bottom of the Device Selection box a field displays the analysis string being constructed The symbol refers to All Next do the following 3 10 In the Item drop down list box select an item to monitor for this analysis string Examples of items include Command Finished Minimum Maximum Average I O Size Minimum Maximum Average Response Time Errors etc In the Operation drop down list box select an operation to monitor for this analysis string Operations include Read Write Read Write Read and Write In the Color drop down list box select a color to represent this analysis string graphically In the Line drop down list box select a line style to represent this analysis string in a line graph Your string is built Click New to add this string to the display box Repeat steps 1 through 9 to create additional analysis strings if you so desire OR If you want to add to an already built string select the string in the display box select additional devices under Device Selection and click the Add To button If you change the Item Operation Color or Line and click Add To the new selection replaces the previous one To delete analysis strings e Select a string in the display box and click Delete OR 5 38 Click Delete All to delete all defined analysis strings GAM Client v2 30 and WSAM User s Manual
107. lose the Intelligent Battery Backup Unit window without saving any changes Manual No 771961 5 49 Battery Backup Unit Monitoring and Maintenance Mylex External RAID Controllers Figure 5 48 shows the Intelligent BBU window for an External RAID Controller Intelligent Battery Backup Unit 24 x m Power Levels p Battery Status m Actions fi 0 0 Low Power Threshold unknown Battery Type C Set Low Power Threshold C Recondition Battery ao ferent Ene fe Version Discharge Batter 2 aa Fast Charge joo Maum Power Low Power Alarm Stop Recondition I Never Reconditioned fe Charge Level I Reconditioning Needed Apply I Reconditioning Active I Fast Charging Active I Discharging Active Refresh aaa Display C Minutes Hours Figure 5 48 Intelligent BBU External Controllers The Intelligent Battery Backup Unit BBU dialog box is used to monitor and charge or recharge the backup battery pack on the controller This battery pack maintains the controller s data in RAM in case AC power is lost to the disk storage system When a new battery is needed the BBU dialog indicates this by showing the battery can no longer take or hold a charge This dialog box is also used after an old battery pack is replaced with a new one The new battery must be fully discharged before it can be charged up Power Levels The Power Levels area of the Intelligent Battery Backup Unit dialog box conta
108. n 70 00 06 00 00 00 00 QA 00 00 00 0029000000 Fri 8 otl 2 chn tgt 6 lun 0 Unit Attention 7000 06 00 00 00 00 18FF FF FF FF 29020000 Fri 7 otl 2 chn 0 tgt 5 lun 0 Unit Attention 70 00 06 00 00 00 00 18 FF FF FF FF 29020000 Fri 6 otl 2 chn O tgt 0 lun 0 Unit Attention 70 00 06 00 00 00 00 18FF FF FF FF 29020000 Fri 5 otl 2 chn 1 tgt 3 lun 0 Unit Attention 70 00 06 00 00 00 00 QA 00 00 00 00 29000000 Th 4 otl 2 chn 1 tgt 1 lun 0 Unit Attention 70 00 06 0000000004 00 00 00 0029000000 Th 3 otl 2 chn 1 tgt 0 lun 0 Unit Attention 70 00 06 00 00 00 00 OA 00 00 00 0029000000 Th 2 etl 2 chn O tgt 6 lun 0 Unit Attention 70 00 06 00000000 18FFFFFFFF 29020000 Th 1 etl 2 chn 0 tgt 5 lun 0 Unit Attention 700006 00000000 18FFFFFFFF 29020000 Th 0 ctl 2 chn 0 tgt 0 lun 0 Unit Attention 70 00 06 00 00 00 00 18 FF FF FF FF 29020000 Th x Figure 5 16 Request Sense Data This information may be useful for troubleshooting or later analysis 1 Click Save File to record the request sense data for later use 2 Click Close to close the Error Table Manual No 771961 5 17 Physical Device and Logical Drive Monitoring Displaying Logical Drive Information The icons on the right side of the Controller View window represent the logical drives also known as logical units or system drives created by the controller out of the available physical drives Double click a logical drive icon to display information about a particular
109. n sessions 1 1 5 2 Data Bits e Select the number of data bits required for communication sessions 4 5 6 7 8 Finish by doing one of the following e Click OK to accept the communication settings and exit the Settings dialog box or Click Cancel to leave original settings unchanged or Click another Settings tab to set additional user preferences Event Editor al Ragen DEE Figure 4 20 Settings Dialog Box Event Editor 418 GAM Client v2 30 and WSAM User s Manual Configuration In the Settings dialog box under the Event Editor tab Figure 4 20 you have the option to do any of the following GAM ID User Evenit Severity Default e Select a GAM event ID to edit from the GAM ID list box e Enter your own number for this event in the User Event list box or keep the default equal to the GAM ID number e Enter your own event severity level in the Severity list box or keep the default set by Mylex e Click the Default button to return all settings for this particular event to their Mylex defaults Alarm for the Event e When all Global boxes are checked you are seeing the alarms that will activate when this particular event occurs these are based on the settings in Alert Preferences Check or uncheck specific boxes if you wish to override these defaults and change the alarms for this event Event Message Text e Enter new text for this event or keep the default text set by My
110. ncy check process The Write Back Bad Block Table stores information on all irrecoverable write back errors that occur GAM provides an Error Table in which you can see Bad Block Data and Request Sense Data Battery Backup Unit A Battery Backup Unit is an add on module that provides power to a Mylex Disk Array Controller cache memory in the event of a power failure The battery backup module monitors the write back cache on the controller and provides power to the cache if it contains data not yet written to the drives when power is lost Cache Controller memory used to speed up data transfer to and from a disk Cache Flush Refers to an operation where all unwritten blocks in a Write Back Cache are written to the target disk This operation is necessary before powering down the system Manual No 771961 G 1 Glossary Cache Line Size The Cache Line Size function available in Controller Options or Manual Configuration is set in conjunction with stripe size and represents the size of the data chunk that will be read or written at one time The cache line size should be based on the stripe size you selected Channel Refers to one bus on a Mylex Disk Array Controller Each controller provides at least one channel and additional channels with optional upgrades Consistency Check Refers to a process where the integrity of redundant data is verified For example a consistency check of a mirrored drive will make sure t
111. nd start the GAM Server component before you attempt to run the GAM Client component Under Windows NT 4 0 or Windows 95 98 you are ready to start up the Global Array Manager Client once you have installed the client on your workstation see the previous chapter Manual No 771961 3 1 Navigating Global Array Manager Client or Workstation Array Manager e Start the GAM Client software Start gt Programs gt Mylex Global Array Manager Client If at least one server group and file server are defined the opening screen appears If not the Define Server Groups dialog box appears see Setting Up Server Groups and Servers on page 4 4 Note After starting the Global Array Manager Client minimize the utility and let it run in the background at all times unless you re doing a configuration or setting up a maintenance process If Global Array Manager detects a logical drive in a critical state or a physical drive failing it prompts you with windows describing the location and nature of the problem Maximize the utility to display more detailed information In order for event notification to occur the Global Array Manager Server and Client must be running at all times Workstation Array Manager Component Under Windows NT 4 0 you are ready to start up the Workstation Array Manager once you have installed this component on your workstation see the previous chapter e Start the WSAM software Start gt Programs gt Myle
112. ndow The major components of the Global Status View window Figure 3 1 are described below 5 Item 5 is an icon that represents the currently selected file server 3 4 running the GAM Server component The icon identifies e the IP address e g 192 192 200 5 or name e g ide40 of the server e the network operating system running on the server e g SCO SCO OpenServer NT Windows NT NW Novell NetWare etc e the operational status of the server green functioning yellow critical red X down or nonfunctional GAM Client v2 30 and WSAM User s Manual Startup amp Navigation the number of DAC PCI SCSI or External RAID controllers and or SCSI HBA controllers connected on the server with a controller operational status light green functioning yellow critical red X down or nonfunctional 6 Item 6 is an icon that represents a currently unselected file server running the GAM Server component The icon identifies the same information described above under currently selected file server Components of the Log Information Viewer 7 Item 7 in Figure 3 1 is the GAM Client Log Information Viewer Each line in the Log Information Viewer identifies a single event error status warning etc which was noted during monitoring by a file server running GAM Server and was transmitted by that server to this client workstation Relevant details accompany the event Event ID Displays an icon sho
113. ne System is disconnecting from this controller 395 Controller is gone System is disconnecting from this controller 398 Controller is gone System is disconnecting from this controller Serious Level 1 12 A hard disk has failed 134 A logical drive has been made offline 156 Bad data blocks found Possible data loss Manual No 771961 A 1 Errors Level 2 256 258 272 274 288 291 304 517 Fan failure Fan failure Power supply failure Power supply failure Over temperature Temperature is above 70 degrees Celsius Over temperature StorageWorks enclosure reported failure state Lost connection to server or server is down Errors Level 2 9 10 11 18 131 132 135 141 142 143 147 152 385 Rebuild stopped with error Rebuild stopped with error New device failed Rebuild stopped because logical drive failed Expand Capacity Stopped with error Consistency check on logical drive error Consistency check on logical drive failed A logical drive is critical Rebuild stopped with error Rebuild stopped with error New device failed Rebuild stopped because logical drive failed Logical drive initialization failed Expand Capacity stopped with error Write back error Warnings Level 3 3 4 22 23 Hard drive error found Hard drive PFA condition found this drive may fail soon Parity error found Soft error found GAM Client v2 30 and WSAM User s Manual 24 289 305 386
114. necessary to check the Global Array Manager Client option OR To select Workstation Array Manager for installation click the box to check the Workstation Array Manager option Note If you check Global Array Manager Client you may also choose to install Global Array Manager Server at this time Instructions for GAM Server installation are described in the Software Kit documentation 2 4 GAM Client v2 30 and WSAM User s Manual Installation 7 Click Next to continue with the installation once you ve selected your component s If you selected BOTH Global Array Manager Client AND Workstation Array Manager you will see the following message Figure 2 5 Warning N The Global Array Manager Client and Workstation Array Manager may not be installed at the same time Please deselect one of the selected components Figure 2 5 Error Must Choose GAM Client OR WSAM e If this message appears click OK then deselect either Global Array Manager Client or Workstation Array Manager and click Next If you are attempting to install Workstation Array Manager under Windows 95 or Windows 98 you will see the following message Figure 2 6 Warning You are attempting to install Workstation Array Manager on Windows 95 Workstation Array Manager can only be installed on Windows NT Please deselect the Workstation Array Manager component Figure 2 6 Error WSAM Must Be Installed Under Windows NT e If this messag
115. nerated You can see the data as a line graph on the History page Data will be collected until you click the Stop Capture button You may wish to save the contents of the data buffer to a file for later examination To save the data buffer to a file 1 Click Capture Data 2 Select Save Buffer and type a filename for the data file to be saved or click Browse to find an existing data file and append the buffer to it 3 Click OK 5 40 GAM Client v2 30 and WSAM User s Manual Monitoring To display previously saved data 1 Click Display Data A display Data dialog box opens Figure 5 36 Display Data 2 x Data Source f204 32 130 200 Browse perfdata paf Figure 5 36 Display Data 2 Select a data file to display or click Browse to locate a data file in a different directory Note Selecting the IP Address in the Data source box indicates that you wish to view data currently being generated by that server Only the currently selected server will be displayed 3 Click OK to open the data file for display or the server currently generating data You view saved data by clicking the History tab and choosing Past in the Graph Data box You view current data by clicking the History tab and choosing Present in the Graph Data box Manual No 771961 5 41 Performance Monitoring History Click the History tab to open the History data page Figure 5 37 Statistics 204 32 130 200 x Settings L
116. ning available space in an existing array or create a new array using unconfigured disk drives Existing data will not be affected by this process Expand the capacity of an existing array Existing data will not be affected by this process Expand Aray Cancel Figure 4 30 Select New Configuration The New Configuration option of the Automatic Configuration feature provides the administrator with the option of customizing the automatic configuration Global Array Manager Client creates an autoconfig dat file that can be edited by the administrator The autoconfig dat file can be opened and edited through notepad or another text editing application The new configuration created by the autoconfig dat file is based on the total number of drives discovered by the Global Array Manager The automatic configuration feature uses the maximum number of drives provides a fault Manual No 771961 4 35 Running RAID Assist tolerant RAID level when able and creates a hot spare drive for drive failure protection The number of logical drives created is dependent on the total number of physical drives discovered The administrator can edit the following parameters within the autoconfig dat file e Total number of physical disk drives available e Number of physical disk drives in each logical drive e RAID level valid levels are RAID 0 RAID 1 RAID 3 RAID 5 RAID 0 1 and JBOD e Write ca
117. not installed or has failed in an undetectable way e OK The alarm is optimal One additional item is displayed with this state ON the alarm is currently on or sounding e Failed The alarm is installed but has failed The status of the enclosure s connection to one or more Uninterruptable Power Supplies UPS Each UPS is designated with a number The status values are e Absent The UPS is not installed or has failed in an undetectable GAM Client v2 30 and WSAM User s Manual Monitoring way e OK The UPS is optimal Three additional items are displayed with this state AC Pwr the UPS is reporting an AC power failure DC Pwr the UPS is reporting a DC power failure Low Bat the UPS can power the system for only 2 to 5 more minutes e Failed The UPS is installed but has failed e Error status for troubleshooting purposes Error status for an enclosure is reported in a format similar to the following example 0 Addressing 25 02 03 04 05 e is the error number e Addressing is the error type e 25 is the ALPA Arbitrated Loop Port Address of the drive in question e 02 03 is the first known channel and target to which the ALPA is mapped e 04 05 is the second known channel and target to which the ALPA is mapped e An information field may need to scroll not visible in Figure 5 21 above which contains most of the items listed on the Information page for easier cross reference Click the Close but
118. nt message editing and so on Window Menu Tile Cascade 1 Global Status View 2 Log Information Viewer 3 Controller View 204 32 130 202 Controller2 gamroot Figure 3 8 Window Menu Manual No 771961 3 13 Navigating Global Array Manager Client or Workstation Array Manager The Window menu Figure 3 8 is a standard feature of Windows 95 and Windows NT It is implemented as such in GAM WSAM Help Menu Contents FI About Global Aray Manager Figure 3 9 Help Menu The Help menu Figure 3 9 identifies the on line help options available within the Global Array Manager Client or Workstation Array Manager e Contents Displays a list of available help topics e About Global Array Manager or About Workstation Array Manager Displays the Windows standard About box Toolbar and Toolbar Icons GAM Client and WSAM contain a toolbar Figure 3 10 in the Global Array Manager or Workstation Array Manager window Figure 3 10 Toolbar Each toolbar button corresponds to a function available from the menu bar RAID Assist Brings up the Raid Assist dialog box for RAID controller configuration Scan Devices Scans for new devices recently added and not currently identified within GAM WSAM Display Controller Information Displays key information about the currently selected DAC or HBA 3 14 GAM Client v2 30 and WSAM User s Manual Hi 2 Startup amp Navigation Statistics Vi
119. nubar and Menus GAM Client and WSAM contain a menubar Figure 3 3 in the Global Array Manager or Workstation Array Manager window File Menu Open Configuration Ctrl 0 Save Configuration Ctrl S Clear Configuration Exit Ctrl Q Figure 3 4 File Menu The File menu Figure 3 4 contains the following options e Open Configuration Ctrl O Loads a configuration from disk and saves it to the controller See Loading a Configuration from Disk on page 4 5 e Save Configuration Ctrl S Saves a configuration file to a new filename disk and or directory e Clear Configuration Removes configuration information for the selected controller A Caution Although there are confirmation checkpoints and warnings following selection of this option remember that all existing configuration and file data on all drives connected to the controller will be deleted Exit Ctrl Q Exits the GAM Client or WSAM 3 8 GAM Client v2 30 and WSAM User s Manual Startup amp Navigation View Menu w Global Status View Controller View Statistics View 7 Log Information Viewer Initialize Status Rebuild Status Consistency Check Status Expand Capacity Status Error Table Figure 3 5 View Menu The View menu Figure 3 5 contains the following options Global Status View Toggles the Global Status View window GAM Client only The Global Status View window opens by default wh
120. oller View For WSAM Controller View opens for the C 0 controller on the local server at startup Opening the Controller View Open the Controller View by double clicking any server icon in the Global Status View or as shown in Figure 5 4 v Global Status View Statistics View Log Information Viewer Initialize Status Rebuild Status Consistency Check Status Expand Capacity Status Error Table Figure 5 4 Select Controller View For WSAM you can only access controllers on the local server Open a controller view from the controller selection box Manual No 771961 5 5 Controller Monitoring All RAID Controllers Except Fibre to Fibre Controller View 192 192 192 1 Controller 2 gamroot Physical Drives MB Logical Drives MB Channel 0 0 4096 RAID 3 1 4092 RAIDS Total Logical Capacity 8188 MB Total Physical Capacity 10240 MB Figure 5 5 Controller View Window Non Fibre RAID Controller The Controller View window Figure 5 5 displays the following information about the controller currently selected in the controller selection box e The number of channels on this controller each channel depicted as a tower e The physical devices present on each channel specifying the target ID capacity of the device device type and device status e The logical drives configured on the controller specifying the logical drive number capacity of the lo
121. on for more control over drive group setup or individual configuration parameters Monitoring Functions The Global Array Manager Server component collects and disseminates information on disk array or HBA subsystem status and resource utilization The Global Array Manager Client component organizes this information through an intuitive graphical display Errors and events are recorded in a log and if a problem is serious enough to warrant immediate attention operators can be alerted via popup windows pagers fax or email if so desired Maintenance Functions The Global Array Manager Client or Workstation Array Manager manages or performs maintenance on individual disk arrays and drives with the appropriate authentication again by means of the graphical user interface This includes removing physical devices from operation in a functioning disk array also known as killing or off lining a drive rebuilding drives selecting hot spares and initiating a check of consistency or parity information on arrays that are configured to support redundancy The Global Array Manager Server executes the management instructions specified by the Global Array Manager Client Manual No 771961 1 3 What s New In GAM Version 2 30 What s New In GAM Version 2 30 Global Array Manager Version 2 30 contains new features enhancements and modifications not available in earlier versions of Global Array Manager Support for the Mylex SANAr
122. ormation Viewer The Log Information Viewer Figure 5 2 displays the following information about events Event ID Displays an icon showing whether the event is informational cautionary a warning etc plus the identification number assigned to this event Severity The severity level of this event Source The IP address or name of the file server that is the sender source of this event blank for WSAM Source Time Day of the week month day of the month time of day and year at the source file server s location when this event occurred Device Address Relevant channel target activity and other data pertaining to why this event posted Description Text of the message describing what occurred Sequence Seq Number representing where this event fell in a sequence of possibly related events Local Time Day of the week month day of the month time of day and year at the local client workstation s location when this event arrived Manual No 771961 5 3 Event Monitoring Opening an Event Information Window If you wish to obtain additional information about any event displayed in the Log Information Viewer the program allows you to open an event information window To open the event information window for a particular event 1 Be sure the Log Information Viewer is displayed 2 Determine which event you would like more information about scroll the Log Information Viewer if necessary and single click anywh
123. oup repeat steps through 3 5 Click OK in the Define Server Groups dialog box when you are finished After adding servers Global Array Manager returns to the Global Status window Note Select All Servers to see all servers in the Global Status view Loading a Configuration from Disk Load a previously saved configuration from disk as shown in Figure 4 5 Open Configuration Ctrl 0 Save Configuration Ctrl S Clear Configuration Exit Ctrl Q Figure 4 5 Select Open Configuration Manual No 771961 4 5 Loading a Configuration from Disk 1 In the Open Configuration dialog box Figure 4 6 select the configuration file you wish to open to save to the controller Open Configuration easier AE sconfig qct Ircornct Coroico Cael Figure 4 6 Open Configuration Dialog Box 2 Click Open to access the configuration file A window displays key elements of the configuration you are about to open Figure 4 7 Open Configuration 204 32 130 200 Controller 0 C Program Files Mylex GAM Client myconfig gcf Ea aes Ye le Tl le a Figure 4 7 Stored Configuration Information to be Opened 46 GAM Client v2 30 and WSAM User s Manual Configuration 3 Click Apply to apply the configuration to the controller or click Cancel to stop without applying the saved configuration If you click apply you will be asked to confirm your decision to
124. overwrite the existing configuration Setting and Modifying User Preferences Open Settings as shown in Figure 4 8 Sign On Define Server Groups Select Current Server Group Ctrl G Select Current Controller Ctrl C Raid Assist Initialize Logical Drives Controller Information Enclosure Information Controller Options Intelligent BBU Scan Devices Advanced Functions gt Settings Figure 4 8 Select Settings Manual No 771961 4 7 Setting and Modifying User Preferences Alert Preferences Settings BE Alert Preferences Alarm Setup Communication Event Editor r Event Log Append to log file I Enable event logging Replace loa file faam2ctlog Browse r Enable Global Alerts for Severity Level s Email p Pager gq gd gw wt gj ss ss ss m Fax m Launch Application v di gt gt gg gf gd ww Mo Wi f2 13 Lia a Sound Figure 4 9 Settings Dialog Box Alert Preferences In the Settings dialog box under the Alert Preferences tab Figure 4 9 you have the option to do any of the following Event Log e Append events to your current log file or e Replace the log file overwrite it e Rename the log file e Enable or disable the event logging function Enable Global Alerts for Severity Level s e For each type of alarm Email Pager Fax Launch Application and Alarm Sound check the box es cor
125. p has detected a previous installation of this product in the specified folder Do you want to overwrite the previous installation Figure 2 8 Existing GAM Client Detected Overwrite e Ifthis message appears click Yes to overwrite the existing GAM Client installation OR e Click No to retain the existing GAM Client and select a new destination folder for the new GAM Client then click Next to proceed 2 The Installation Summary screen Figure 2 9 summarizes the components and subcomponents you ve selected for installation Click Next to continue or Back to change selected components Installation Summary When you click Next the following actions will be taken Global Array Manager Client Program Files Will be installed into folder C Program Files Mylex Global Array Manager Client Global Array Manager Server Program Files lt Will not be installed gt Driver lt Will not be installed gt DMI Files lt Will not be copied gt SNMP Files lt Will not be installed gt Workstation Array Manager Program Files lt Will not be installed gt Driver lt Will not be installed gt Figure 2 9 Installation Summary Manual No 771961 2 7 Installation of Global Array Manager Client or Workstation Array Manager 3 During installation files are decompressed and copied from the installation CD ROM to the destination folder Figure 2 10 Copying Global Array Manager Client Files c program fil
126. pping feature is intended for use in configurations in which multiple host computers attach to one or more Mylex controllers This is also referred to as a Storage Area Network SAN configuration The host to LUN mapping feature restricts host access to configured system drives Access to a configured system drive is granted only to a single host or group of hosts Hot Replacement of Disks Hot Swap The design of Mylex RAID controllers allows for the replacement of failed hard disk drives without interruption of system service In the event of a drive failure on a properly configured system where the data G 4 GAM Client v2 30 and WSAM User s Manual Glossary redundancy features of the controller are used system service continues without interruption A message is generated by the system to alert the system operator When a replacement drive becomes available the system operator can remove the failed disk drive install a new disk drive and instruct the controller to rebuild the data on the new drive all without interrupting system operations Once the rebuild is complete the controller will be brought back into a fault tolerant state IBBU See Intelligent Battery Backup Unit Intelligent Battery Backup Unit The Intelligent Battery Backup Unit IBBU is an add on module that provides power to a compatible PCI to Ultra SCSI or External RAID Controller cache memory in the event of a power failure The bat
127. r s Manual Maintenance Processes Using the Flash Utility Open the Flash Utility as shown in Figure 6 3 Sign On Define Server Groups Select Current Server Group Ctri G Select Current Controller Ctrl C Raid Assist Initialize Logical Drives Controller Information Enclosure Information Controller Options Intelligent BBU Scan Devices Advanced Functions Performance Analysis Flash Utility Shutdown Settings Figure 6 3 Select Flash Utility Mylex PCI RAID Controllers The Flash Utility is used to upgrade firmware BIOS and BIOS Configuration Utility software by flashing the new code stored in an identified IMG file to the on board BIOS of the Mylex PCI Disk Array Controller As maintenance releases of this code become available this utility allows you to keep your controller current using GAM or WSAM The Flash Utility dialog box appears as shown in Figure 6 4 Flash Utility 21x r Flash file selection E Browse r Current RAM information Record Type Version Tum No Build Time Flash Time Image Size BootBlock 4 04 28 02 30 1998 02 31 1998 16384 4 05 27 04 01 1998 04 04 1998 229376 4 M1 N7 199R_ 17 17 1998 _377AR of Start Flash Figure 6 4 Flash Utility Dialog Box Manual No 771961 6 5 Using the Flash Utility Under Current RAM Information you see displayed the key information regar
128. r Groups Select Current Server Group Ctl G Select Current Controller Ctrl C Raid Assist Initialize Logical Drives Controller Information Enclosure Information Controller Options Intelligent BBU Scan Devices Advanced Functions gt Settings Figure 5 46 Select Intelligent BBU Mylex PCI RAID Controllers Figure 5 47 shows the Intelligent Battery Backup Unit window for a PCI RAID Controller Intelligent Battery Backup Unit Battery Power Hours __ Charge Level Current 90 0 Max 90 0 Charge Level 100 Threshold 2 j Hours OK Figure 5 47 Intelligent BBU PCI Controllers 5 48 GAM Client v2 30 and WSAM User s Manual Monitoring Mylex PCI RAID Controller BBUs can only be monitored through GAM Client or WSAM BBUs cannot be reconditioned or recharged at this time The only user interactive setting is low power threshold The following information is displayed in the dialog box e A gauge and text showing the current battery power remaining in hours as well as a maximum value e A gauge and text showing the current charge level in percentage points e The low power threshold for the battery in hours When battery power sinks below this threshold an alarm or message will alert the user to a low battery power state Click OK if you changed the threshold value This will accept the change OR Click Cancel to c
129. ray and SANArray Pro External RAID Controllers In addition to support for earlier External SCSI RAID Controllers such as the DAC960SX and External Fibre Channel RAID Controllers such as the DACSF and DACFL GAM Version 2 30 adds full support including controller options for the SANArray e g FFx and SANArray Pro e g DACFF Fibre Channel to Fibre Channel Series of Mylex External RAID Controllers Support for Disk Array Controllers Using External Firmware 6 x Version 2 30 of GAM supports Mylex External Disk Array Controllers which run Mylex External Firmware up to and including Version 6 x Simplified Global Array Manager Component and Subcomponent Installation under Windows NT 95 98 Version 2 30 of GAM includes an enhanced installation wizard which simplifies and combines installation of all GAM components and subcomponents from the distribution CD ROM when running under Windows NT 95 98 Under Windows NT the user can choose to install GAM Server GAM Client or WSAM WSAM by itself or both GAM Server and GAM Client together In addition subcomponents of GAM Server such as DMI and SNMP can be individually selected or deselected for installation New Host to LUN Mapping Dialog Box with Improved Functionality Version 2 30 of GAM includes a new scheme for Host to LUN mapping not available prior to External Firmware Version 6 x This new dialog box and its functionality are fully described in Chapter 4 Physical Disk Drive Fail
130. re from 0 to 255 The version number used for the first release is 1 for the controller production release The following are read only checkbox items which indicate the battery status e Low Power Alarm A low power condition exists as defined when the Current Power value drops below the Low Power Threshold value e Never Reconditioned Battery has not been fully discharged before it was charged up A new battery will have this checked until it has been fully discharged and then charged by the Recondition Battery selection under Actions e Reconditioning Needed Battery has not been reconditioned within 30 discharge charge cycles Select Recondition Battery under Actions then click Apply e Reconditioning Active Process of discharging recharging the battery is underway Allow the process to complete or it will have to be repeated If you do need to interrupt reconditioning select Stop Manual No 771961 5 51 Battery Backup Unit Monitoring and Maintenance Recondition under Actions then click Apply Fast Charging Active Battery is being charged A fast charge also occurs when the controller is powered on Discharging Active Battery is currently discharging which is the first stage of a Recondition Battery action Actions The Actions area of the Intelligent Battery Backup Unit dialog box contains the following 5 52 Set Low Power Threshold First edit the Low Power Threshold field under Power Levels To change th
131. responding to the event severity level s for which you would like to enable this type of alarm globally For example in Figure 4 9 all Level 0 and Level 1 messages events will result in an alarm sound locally and email page Level 0 only and fax to those individuals identified in Alarm Setup 4 8 GAM Client v2 30 and WSAM User s Manual Configuration Events are numbered from 0 for most severe to 4 for least severe and can be edited by the user Finish by doing one of the following e Click OK to accept the global alert settings and exit the Settings dialog box or Click Cancel to leave original settings unchanged or Click another Settings tab to set additional user preferences Alarm Setup Settings x Alert Preferences Alarm Setup Communication Event Editor 2 Pager 555 1234 Modem setup string _Hangup stri AT amp F amp C1 amp D2L1 ATHO w Add Remove Properties Figure 4 10 Settings Dialog Box Alarm Setup The top half of the Alarm Setup dialog box lists the types of alarms that can be used Pager Fax Email Launch Application The lower half of the Alarm Setup dialog box lists the currently defined destinations recipients applications for the alarm type selected in the upper window Figure 4 10 Add a Pager 1 Select the Pager alarm type in the upper window 2 Click Add The Pager setup box is displayed as shown in Figure 4 11 Manual No 771961 4
132. ripe size and retains in cache any data beyond the size of the actual read request Disconnect On First Command Allows target to disconnect from initiator Background Initialization Allows logical drive initialization to take place behind the scenes so that the logical drive is immediately available for use If you disable this option logical drives will need to complete their initialization process before they can be used e Change the default Rebuild Rate to less than or equal to 50 A rate of 50 devotes the maximum allowable resources to a drive rebuild or array expansion allowing the Rebuild or Expand to proceed at its fastest Lowering the number devotes more resources to I Os and consequently slows the Rebuild or Expand Array process e Change any of the following Startup Parameters Spin up Change if you do not want automatic drive spin up Devices Between Spins Number of devices to spin up at one time A low number lessens the likelihood of a power drain Initial Delay Number of seconds between physical device start ups Manual No 771961 4 21 Setting and Modifying Controller Options Sequential Delay Number of seconds between consecutive device spin up cycles e Change any of the following SCSI Parameters note that Transfer Speed is read only Channel for this controller Whether the controller will handle data at 8 bit or 16 bit transfers Maximum data transfer rate of the disk side channels Spee
133. rives may result in a loss of data Note T O operation can only be performed with logical drives that are online or critical Offline A Logical Drive is in an offline state if No data can be read from it or written to it System commands issued to offline logical drives are returned with an error status no operations can be performed on offline logical drives A logical drive can be offline under one of two situations described below e Itis configured with a redundant RAID level 1 3 5 or 0 1 and two or more of its member drives are not online or e Itis configured at RAID level 0 JBOD or in a spanned set PCI only and one or more of its member drives are not online G 6 GAM Client v2 30 and WSAM User s Manual Glossary Logical Drives A logical drive is equivalent to a system drive Logical drives are presented to the operating system as available disk drives each with a capacity specified by the Mylex Disk Array Controller Logical Unit Number LUN A SCSI representation of a system drive logical drive on a given channel and target ID Mirroring Refers to the 100 duplication of data on one disk drive to another disk drive Each disk will be the mirror image of the other Pack See Drive Groups or Drive Packs Parity See Rotated XOR Redundancy Physical Drive States Refers to a drive s current operational status At any given time a drive c
134. roceed confirm by typing the word YES el Eos Figure 4 41 WARNING Before Applying the Configuration 4 Type YES and click OK if you are sure you want to apply the new configuration and overwrite the old If you re not sure click Cancel Note In Assisted Configuration Add Logical Drive and Expand Array function very similarly to the New Configuration option In each case RAID Assist leads you step by step through the relevant questions for the task Manual Configuration Manual Configuration provides four options e Edit Configuration Displays the current configuration disk arrays and logical drives and allows you to make any changes that you require e New Configuration Sets up a new configuration on the controller deleting the previous configuration and data if any e Add Logical Drive Sets up additional arrays logical drives leaving the existing array s intact At least one array must be configured on this controller and unconfigured drive space must remain e Expand Array Restripes data in your array across additional unconfigured drives to expand the capacity of the array Manual No 771961 4 47 Running RAID Assist Open New Configuration for example as shown in Figure 4 42 Manual Configuration Figure 4 42 Select New Configuration Manual Configuration New Configuration 204 32 130 202 Controller 2 Seale Soe ns Figure 4 43 Manual Configuration Disk A
135. rovides transparent failover failback and should not be used in conjunction with an alternate path driver Required for FFx controllers Topologies may be changed with some side effects e When changing from inactive port to master slave mapping logical drives associated with controller 1 port 1 will be reassigned to controller 0 port 1 e When changing from master slave to inactive port port mapping associated with controller 0 port 1 will be reassigned to controller 1 port 1 e When changing from master slave or inactive port to multi TID or MultiPort the inactive ports will be enabled and all port mapping will remain unchanged e When changing from multi TID or multiPort to master slave or inactive all mapping on the inactive ports will be lost Selecting the Port Selection of the active port being configured is determined by the topology selected Inactive ports for the given topology are disabled and not available for selection The host to logical drive list and logical drive to LUN list are displayed for the selected port Logical Drive to LUN Mapping Logical Drive to LUN Mapping associates a logical drive defined in the configuration with a LUN The main list control displays the logical drive LD RAID level and size and LUN assignment If no LUN is associated with the logical drive the LUN field is blank 4 56 GAM Client v2 30 and WSAM User s Manual Configuration When a logical drive is selected the LU
136. rray Manager or Workstation Array Manager 3 15 Exiting GAM Client or WSAM eceesceeeceeseeeeeeeeeeeteaeeeneeeneeeeas 3 15 Manual No 771961 v Exiting GAM Servet T 3 16 For More Information ceeescceesseeeeeneeeeeeeeeeneeeeeeeeeeesneeessnneeeseeees 3 16 Chapter 4 Configuration INTODUCHON ect ht hatte eet Aas ee eve 4 1 Signing ON to a Servet sesei ia a 4 1 Security Access Levels eceeeeeceteeeeeeeeeeeeteeeeeeteaeeeeeeseeeteatens 4 1 SIQNING ONisti5 teehee Sees ee te ee een Se 4 2 Setting Up Server Groups and Servers ceeceeseeeeeeeeeeneeteteeeneeeneees 4 4 Adding a Server Group to the Server Group List 4 4 Adding a Server to the Servers List cesceeseeseeeeeeeeeeeeneereaes 4 5 Loading a Configuration from Disk ccceeceeeseeeeeeeeeeeteeeeeeeeeeeeaeeees 4 5 Setting and Modifying User Preferences eccccseeeeseeeteeeneeeneees 4 7 Alert Preferences esecccceecceeseceeseeeeeeeeneesneneesesesensseeenseneeeesees 4 8 Alarm Setup sis hiatal a a eN E achat 4 9 Communication sessen a a a 4 17 Event Editor sonantia es in ial 4 18 Setting and Modifying Controller Options c cceseeeeeeseeeeteeeeeeeees 4 20 Mylex PCI RAID Controllers eeceeceeeceeeeeeeeeeeeeeeeeeteneeeneeenaees 4 20 Mylex External RAID Controllers ccceecceeeceeeeeeeeeeeeeeeeeeeeaees 4 23 SCSI Host Bus Adapters 00 eeeeeeeceeeeeeeeeeteaeeeeeeseeeeeeeenenaes 4 31 Running RAID ASSISt i i e darr
137. rrays 448 GAM Client v2 30 and WSAM User s Manual Configuration The Disk Arrays tab in Manual Configuration is where you begin to configure your unused disk drives lower left Figure 4 43 Each disk array is represented by one line in the Disk Arrays area of the screen upper left Figure 4 43 Logical drives if any have already been configured appear on the right side Note For External RAID Controllers there will be a fourth tab called 4 LUN Mapping The Apply button for External RAID Controller configuration resides on the LUN Mapping page See Host to LUN Mapping in Global Array Manager on page 4 55 for more information Do the following 1 Select an unused drive and drag it to the Disk Array AO section The drive will be part of a disk array referred to as A0 2 Select other unused drives and drag them to Disk Array AO OR click the Add Array button to create a row for Disk Array A1 then A2 A3 etc then drag unused drives to A1 if you so desire 3 If you want to manually configure a hot spare click an unused drive then click the Make Spare button 4 If you want to start over click the Clear All button and start again Manual No 771961 4 49 Running RAID Assist 5 Once you ve assembled the disk array groups click the Logical Drives tab to continue on to logical drive setup Figure 4 44 Manual Configuration New Configuration 204 32 130 202 Controller 2 1 Welcom
138. rrors 0 Misc Errors 0 Meke HotSpare Make Offline Rebuild Make Online Figure 5 13 Disk Device Information Device Information Figure 5 12 Figure 5 13 displays the following about the currently selected physical device Device Information RAID Controller e The vendor or source of the controller e The controller s product identification such as DAC960SX e The revision level of the hardware e The back end bus width in bits e Whether the following parameters are set to Yes or No Synch Soft Reset Linked Command Queuing e ANSI Version supported e Back end transfer speed and bus width device state Device Information Disk Drive e The vendor or source of the drive e The drive s product identification such as ST118202FC e The revision level of the firmware in the drive e The back end bus width in bits 5 14 GAM Client v2 30 and WSAM User s Manual Monitoring Whether the following parameters are set to Yes or No Synch Soft Reset Linked Command Queuing ANSI Version supported Disk drive serial number The back end negotiated transfer speed MB sec and back end negotiated bus width The physical capacity of the disk device in MB Sector size usually 512 bytes The current status of the disk online offline etc and a failure indicator if the disk drive has failed refer to Appendix A for a list of error codes The number of soft hard parity and miscellaneous erro
139. rs registered In the disk drive Device Information dialog box Click the Reset Errors button to return all error tallies to 0 If the disk drive s status is Rebuild the Rebuild button may be available so that you can initiate a physical device rebuild If the physical device is unconfigured the Make Hot Spare button may be available to set this device as a hot spare Make Online and Make Offline buttons should be used with great caution Refer to the online help file or call Mylex for support on these options In any Device Information dialog box Click the Close button to close the dialog box Manual No 771961 5 15 Physical Device and Logical Drive Monitoring Viewing the Bad Block Table and Request Sense Data Open the Error Table as shown in Figure 5 14 v Global Status View Controller View Statistics View Log Information Viewer Initialize Status Rebuild Status Consistency Check Status Expand Capacity Status Figure 5 14 Select Error Table A screen of the following type appears Figure 5 15 Error Table 2 x Bad Block Table Request Sense Data Seq _ Device Address Bad Block Number Time 19 otl 4 logdry 0 00055200 Thu Sep 25 19 00 23 1997 18 otl 4 logdry 0 00055900 Thu Sep 25 19 00 23 1997 7 otl 4 logdry 0 00055800 Thu Sep 25 19 00 23 1997 16 otl 4 logdry 0 00055700 Thu Sep 25 19 00 23 1997 15 otl 4 logdry 0 00055600 Thu Sep 25 1
140. s Setup program Click Cancel to quit Setup and then close any programs you have running Click Next to continue with the Setup program WARNING This program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under law Cancel Figure 2 3 Welcome Dialog Box Manual No 771961 2 3 Installation of Global Array Manager Client or Workstation Array Manager 5 Click Yes to accept the Mylex Software License Agreement Note If you click No you will not be allowed to continue with software installation The Select Components dialog box is displayed as shown in Figure 2 4 At this point you will select the component s you wish to install Select Components x Select the components you want to install clear the components you do not want to install Components Global Array Manager Client Global Aray Manager Server OK Workstation Array Manager 0K Description Requires that the Global Array Manager mie Server component be installed on this or some other network attached computer Space Required 2913K Space Available 35824 K lt Back Next gt Cancel Figure 2 4 Select Components to Install 6 To select Global Array Manager Client for installation click the box if
141. s the controller pair selections The Controller View Window 5 Item 5 in Figure 3 2 is the Controller View for the controller selected in the controller selection box WSAM opens with the controller view of controller C 0 displayed by default The controller view displays controller channels physical devices and logical drives See Chapter 5 for additional information Components of the Log Information Viewer 6 Item 6 in Figure 3 2 is the WSAM Log Information Viewer Each line in the Log Information Viewer identifies a single event error status warning etc which was noted during monitoring by the local server and was transmitted to WSAM Relevant details accompany the event Event ID Displays an icon showing whether the event is informational cautionary a warning etc plus the identification number assigned to this event Severity The severity level of this event e Source The source is always the local server This column is blank Source Time Day of the week month day of the month time of day and year on the local server when this event occurred e Device Address Relevant channel target activity and other data pertaining to why this event posted e Description Text of the message describing what occurred e Sequence Seq Number representing where this event fell in a sequence of possibly related events Manual No 771961 3 7 Navigating Global Array Manager Client or Workstation Array Manager Me
142. sconnect m Startup Parameters Spin up no Spin up x Delay 4 Sec oe Figure 4 27 Controller Options Dialog Box For SCSI HBA In the Controller Options dialog box Figure 4 27 you have the option to do any of the following Manual No 771961 4 31 Setting and Modifying Controller Options e Enable by checking or disable by unchecking the following SCSI Device Parameters e Wide Negotiation Allows the controller to negotiate at wide data transfer rates e Disconnect Allows the target to disconnect from the initiator e Change the SCSI ID of this HBA e Change either of the following Startup Parameters e Spin up No Spin up Controller spin up e Delay Number of seconds before physical device startup e Change the following SCSI Device Parameter e Maximum data transfer rate of the disk side channels Speeds are Asynchronous 5 MHz 10 MHz and 20 MHz Click the OK button to accept the changes or the Cancel button to delete them 4 32 GAM Client v2 30 and WSAM User s Manual Configuration Running RAID Assist RAID Assist is the Global Array Manager Client s wizard for the setup and configuration of new logical drives and disk arrays In its simplest form RAID Assist provides an Auto Configuration option which immediately configures all available drives into an optimal RAID 5 configuration RAID Assist s Assisted Configuration sets up a new array according to predef
143. st Connection Information HBA number channel ID and target ID e The status of a partner controller in a dual active pair e Whether the controller is set up to operate as part of a dual active fault tolerant pair e The slot number port number port ID and World Wide Name if any of this specific controller Click the Kill Partner button to cause this controller s partner controller to be placed in reset The controller must be in duplex This is required before Expand Array Click the Relinquish Partner button to cause this controller s partner controller to return to an operating state This is required after Expand Array completes Click the Controller Options button to view a dialog box of user definable controller parameters see Setting and Modifying Controller Options on page 4 20 Click the Close button to close the Controller Information window 5 12 GAM Client v2 30 and WSAM User s Manual Monitoring Physical Device and Logical Drive Monitoring Displaying Device Information The Controller View window details which physical devices are associated with each controller channel Each stack of drives represents the physical drives connected to a single channel on the controller A physical device can be a host controller a CD ROM drive disk drive tape drive etc Double click a physical device icon to display information about a particular physical device Note A physical device icon representing
144. stallation or 31 2 inch disk drive for diskette installation e Fixed disk with at least 8 MB available free space 16 MB recommended e Mouse or other pointing device e GAM Only Appropriate network drivers for the installed network interface card e GAM Only For proper client component connectivity installed and functioning GAM Server software component on the server under any of the supported operating systems NetWare 4 11 4 2 or 5 0 Windows NT 4 0 SCO UNIX OpenServer 5 0 4 UnixWare 2 1 x or 7 0 Manual No 771961 1 5 Requirements e For GAM component installation and operation Microsoft Windows NT 4 0 Microsoft Windows 95 or Windows 98 installed on a local hard disk e For WSAM component installation and operation Microsoft Windows NT 4 0 installed on a local hard disk e GAM Only TCP IP stack installed Optional e Modem or Fax Modem Hayes compatible e MAPI compliant messaging client e g Microsoft Mail Required for Windows NT Microsoft Exchange and Microsoft At Work Fax for fax notification of events Windows 95 only Refer to your server documentation and to the Windows documentation for more information on hardware and operating system requirements 1 6 GAM Client v2 30 and WSAM User s Manual Chapter 2 Installation Installation Overview Installation of the Global Array Manager Client component requires one of the following operating systems e Windows NT 4 0 e Windows 95 e Windows 9
145. t box 2 Click Apply Each horizontal grid mark s value for example from 0 to 1 1 to 2 etc will equal the number of seconds you ve specified The Graph Data box allows you to see currently generated data from the selected server Present or previously saved data Past from the buffer or from a data file selected within the Settings page 5 32 GAM Client v2 30 and WSAM User s Manual Monitoring To pause or resume the data display e Click Pause or Resume if previously paused To change Graph Options for a particular analysis string 1 Select the analysis string of interest in the display window 2 Click Graph Options You can change whether this string s data will be visible whether the data will autoscale along the Y axis the Y axis multiplier and Y offset Note If you want to compare data from different analysis strings their Y multiplier and Y offset settings should be the same To exit e Click Close to exit from Statistics View OR Click another Statistics View tab Manual No 771961 5 33 Performance Monitoring Pie Graph Click the Pie Graph tab to open the Pie Graph data page Figure 5 29 Statistics 204 32 130 200 x Settings Line Graph Pie Graph Bar Graph Device Operation Color Value Value THO Chn Tat0 T gt2 T td Heads l 504 iChat atate Heads 436 Close Figure 5 29 Statistics View Pie Graph Display
146. t for the following e Workstation Array Manager WSAM is used to monitor manage maintain and configure only Mylex Disk Array Controllers physical devices and logical drives that reside on the individual workstation where WSAM is running WSAM cannot access remote servers and work with controllers or devices connected to those servers e WSAM runs only under Windows NT while GAM Client can run under Windows NT Windows 95 or Windows 98 e Workstation Array Manager has no Global Status View and does not include any of the network related components available through Global Array Manager Client Most functions of GAM Client 2 30 however are available in WSAM so this manual applies to both versions Global Array Manager Components Global Array Manager has three components e Global Array Manager Server component which is part of the Mylex Disk Array Controller Software Kit e Global Array Manager Client component e Workstation Array Manager component Each component handles specific tasks based upon the selected function 1 2 GAM Client v2 30 and WSAM User s Manual Introduction Configuration Functions Configuration functions are easily performed using RAID Assist an intuitive wizard like utility in the GAM Client and WSAM components that simplifies the process of setting up or reconfiguring a disk array Just answer a few brief questions and RAID Assist automatically does the rest Use Manual Configurati
147. tery backup module monitors the write back cache on the controller and provides power to the cache if it contains data not yet written to the drives when power is lost A PCI to Ultra SCSI RAID controller with the IBBU installed together occupy only one PCI slot on the host backplane LUN See Logical Unit Number LUN LUN Mapping External RAID Controller LUN Mapping allows logical drives or system drives to be made available or unavailable on one or more host ports The mapping is performed by assigning Logical Unit Numbers LUNs to logical drives The LUN assignments are per host port and are independent of the assignments on other host ports Logical drives may be assigned only one LUN per host port Manual No 771961 G 5 Glossary By not assigning a LUN to a logical drive on a particular host port that logical drive is made inaccessible to that host port Logical Drive States The state of a logical system drive can be either ONLINE CRITICAL or OFFLINE Notice that the same term online is used for both physical and logical drives Online A Logical Drive is in an online state if All of its member drives are online Critical A Logical Drive is in a critical state if It has been configured at RAID level 1 3 5 or 0 1 and One and only one of its member drives is not online A logical drive is considered critical because any failure of another of its member d
148. tion launch using the settings you ve input click Test 5 When you are satisfied with the application you ve set up click OK Your new application entry appears in the lower window of the Alarm Setup dialog box Refer back to Figure 4 17 for an example Remove an Application to Launch 1 Select the Launch Application alarm type in the upper window of Alarm Setup 2 Select the Launch Application entry to remove in the lower window of Alarm Setup 3 Click Remove 4 16 GAM Client v2 30 and WSAM User s Manual Configuration 4 At the confirmation message click Yes to remove the application entry or click Cancel to keep the entry Properties For any of the four alarm types Pager Fax Email Application you may view a particular entry s settings by selecting an entry in the lower window of Alarm Setup and clicking Properties Communication Figure 4 19 Settings Dialog Box Communication In the Settings dialog box under the Communication tab Figure 4 19 you have the option to change any of the following Baud Rate e Select the baud rate appropriate to your communication hardware Port e Select the COM port at which your communication hardware resides Manual No 771961 4 17 Setting and Modifying User Preferences Parity e Select the type of parity for communication sessions None Even Odd Mark Space Stop Bits e Select the number of stop bits required for communicatio
149. tiplier and Y offset Note If you want to compare data from different analysis strings their Y multiplier and Y offset settings should be the same To exit e Click Close to exit from Statistics View OR Click the Settings tab Process Status Monitoring Initialization Status If logical drives are currently being initialized open the Initialize Status box as shown in Figure 5 38 to monitor the progress of or cancel the process Global Status View Controller View Statistics View v Log Information Viewer Initialize Status Rebuild Status Consistency Check Status Expand Capacity Status Error Table Figure 5 38 Select Initialize Status Manual No 771961 5 43 Process Status Monitoring Initialize Status Controller 2 BBE Drive Cancel Done O MA y Select All Clear 4 Figure 5 39 Initialization Status Box The Initialize Status box Figure 5 39 displays the progress of one or more full logical drive initializations To cancel ALL drive initializations at the same time e Click the Select All button which selects all drives for cancellation then click Cancel to stop all the initializations To cancel individual drive initializations e Check the box es of the drive s to cancel then click Cancel to stop only those initializations If all drives are selected for cancellation and you wish to reverse that e Click the Clear
150. ton to close the dialog box Manual No 771961 5 25 Performance Monitoring Performance Monitoring Performance can be monitored in two ways Statistics View This measures RAID controller performance using operations such as Reads Writes Reads Writes Cache Hits etc A flexible settings page lets you choose which controllers targets and operations to monitor Past and present data can be viewed as a line graph pie graph or bar graph Settings can be saved and opened and statistics data can be captured saved and displayed Performance Analysis AVAILABLE WITH MYLEX PCI RAID CONTROLLERS ONLY This focuses on disk level performance as often used in a TPC C environment This system side tool uses items such as Command Completion Time Retries etc to monitor and analyze performance A flexible settings page lets you choose which controllers targets and operations to monitor Past and present data can be viewed as a line graph in a History window Settings can be saved and opened and performance data can be captured saved and displayed Statistics View Open the Statistics View as shown in Figure 5 22 5 26 Global Status View Controller View Log Information Viewer Initialize Status Rebuild Status Consistency Check Status Expand Capacity Status Error Table Figure 5 22 Select Statistics View GAM Client v2 30 and WSAM User s Manual Monitoring Settings
151. toring In Device Selection do the following 2 Select one or more controllers to include in the analysis string Click All for all controllers For individual controllers make sure All is not highlighted Select one or more channels to include in the analysis string Click All for all channels For individual channels make sure All is not highlighted If you chose Physical under Device type select one or more targets to include in the analysis string Click All for all targets For individual targets make sure All is not highlighted If you chose Logical under Device type select one or more logical drives to include in the analysis string Click All for all logical drives For individual logical drives make sure All is not highlighted At the bottom of the Device Selection box a field displays the analysis string being constructed The symbol refers to All Next do the following 5 In the Operation drop down list box select an operation to monitor for this analysis string Examples of operations include Reads ReadKB Writes WritesKB Read Write Read Write etc In the Color drop down list box select a color to represent this analysis string graphically In the Line drop down list box select a line style to represent this analysis string in a line graph Your string is built Click New to add this string to the display box Repeat steps 1 through 8 to create additional analysis strings if you so
152. troller directly Manual No 771961 5 9 Controller Monitoring Displaying Controller Information Open Controller Information as shown in Figure 5 9 Administration Controller Information Figure 5 9 Select Controller Information Mylex PCI RAID Controllers Figure 5 10 shows the Controller Information window for a PCI RAID Controller 204 32 130 200 Controller O gamroot Figure 5 10 Controller Information PCI Controllers The following information is displayed e The controller model e Whether an Intelligent Battery Backup Unit is installed N A for not 5 10 GAM Client v2 30 and WSAM User s Manual supported on the current controller e The firmware and BIOS versions residing on the controller e The cache size and FlashROM size e The bus width for data transfers and bus speed MB sec e The bus type PCI and number of channels on the controller Monitoring e The number of physical devices detected and the maximum number of physical devices that this controller can hold e The number of logical drives configured on this controller and the maximum number of logical drives that can be configured e Host information bus number slot number and IRQ Click the Controller Options button to view a dialog box of user definable controller parameters see Setting and Modifying Controller Options on page 4 20 Click the Close button to close the Controller Information window
153. uild failed drives Stripe Size The stripe size is defined as the size in kilobytes 1024 bytes of a single I O operation A stripe of data data residing in actual physical disk sectors which are logically ordered first to last is divided over all drive group disks Stripe Width The number of striped drives within a drive group Striping Refers to the storing of a sequential block of incoming data across multiple drives in a group For example if there are 3 drives in a group the data will be separated into blocks and block 1 of the data will be stored on drive 1 block 2 on drive 2 block 3 on drive 3 block 4 on drive 1 block 5 on drive 2 and so on This storage method increases the disk system throughput by ensuring a balanced load among all drives System Drive Affinity See LUN Mapping System Drives See Logical Drives G 12 GAM Client v2 30 and WSAM User s Manual Glossary Target ID A target ID is the ID of a device attached to a controller Write Back Cache Refers to a caching strategy whereby write operations result in a completion signal being sent to the host operating system as soon as the cache not the disk drive receives the data to be written The target drive will receive the data at a more appropriate time in order to increase controller performance An optional cache battery backup or an Uninterruptable Power Supply UPS can be used to protect against data loss as a result o
154. ure Codes Version 2 30 of GAM adds physical disk drive failure codes to help pinpoint the cause of a disk drive error These codes if called for will be displayed in the Failure Indicator area of the Disk Device Information dialog box The failure codes are defined in Appendix A and in the GAM Online Help 1 4 GAM Client v2 30 and WSAM User s Manual Introduction Requirements GAM Because Global Array Manager is a client server application the GAM Server software component provided in the Mylex Disk Array Controller Software Kit must be installed in one or more file servers in order for the GAM Client software component to operate Hardware and software requirements for installation and operation of the GAM Server component are described for each supported network operating system in the Mylex Disk Array Controller Software Kit Installation Guide and User Manual WSAM If remote server access is not required Workstation Array Manager can be installed instead of GAM Client on a Windows NT workstation WSAM requires only that Windows NT be running it does not require installation of GAM Server or GAM Client on any system Client and Workstation Hardware and Software e PC compatible computer with an 80486 or higher class processor and at least 4 MB of system memory Pentium processor and 16 MB of system memory are recommended e GAM Only Network interface card connected to a functioning network e CD ROM drive for CD ROM in
155. window of Alarm Setup Select the Email entry to remove in the lower window of Alarm Setup Click Remove At the confirmation message click Yes to remove the Email entry or click Cancel to keep the entry Add an Application to Launch 1 Select the Launch Application alarm type in the upper window of the Alarm Setup dialog box Figure 4 17 Settings BE Alert Preferences Alarm Setup Communication Event Editor Pager amp Fax H E Email amp Launch Application E C Program Files MyApps Notify exe Application Name Launch Once VEL C Program Files MyApps Notify exe Yes Froperies Figure 4 17 Launch Application Alarm Setup 2 Click Add Manual No 771961 4 15 Setting and Modifying User Preferences The Launch Application setup box is displayed as shown in Figure 4 18 Launch Application 24 x M Enabled Launch Only Once r Application Name e Browse Test Cancel Figure 4 18 Launch Application Setup Dialog Box 3 In the Launch Application box e Enable or disable this Application entry using the Enabled check box e Enable Launch Only Once if you want to prevent the application from launching again if GAM detects that it is already running e Enter the name of an application to launch should certain events or messages require it e If you don t remember the name or path of the application click the Browse button 4 To test the applica
156. wing whether the event is informational cautionary a warning etc plus the identification number assigned to this event Severity The severity level of this event Source The IP address or name of the file server that is the sender source of this event Source Time Day of the week month day of the month time of day and year at the source file server s location when this event occurred Device Address Relevant channel target activity and other data pertaining to why this event posted Description Text of the message describing what occurred Sequence Seq Number representing where this event fell in a sequence of possibly related events Local Time Day of the week month day of the month time of day and year at the local client workstation s location when this event arrived Manual No 771961 3 5 Navigating Global Array Manager Client or Workstation Array Manager Components of the WSAM Opening Screen Upon startup Workstation Array Manager displays the opening screen consisting of the Workstation Array Manager window the Controller View window and the Log Information Viewer Figure 3 2 Workstation Array Manager Jof x File View Administration Window Help 1 v ME DAC1164P ol bite SE Solal HAQCAL SERVER al Controller View Controller 0 ogical Drives MB H 2 0 ESS 658 RAIDS Physical Devices MB 5 Description Thu Mar 18 15 46 17 1
157. with rotated XOR redundancy Level 0 1 Combines RAID 0 striping and RAID 1 mirroring This level provides redundancy through mirroring Mylex RAID 6 Levels 00 10 30 and 50 Multi layer RAID levels which span RAID levels 0 1 3 and 5 by striping data across drive groups RAID Drives JBOD Sometimes referred to as Just a Bunch of Drives Each drive is operated independently like a normal disk drive or drives may be spanned and seen as a single drive This level does not provide data redundancy Mylex RAID 7 Manual No 771961 G 9 Glossary Note The host operating system drivers and software utilities remain unchanged regardless of the level of RAID installed The controller makes the physical configuration and RAID level implementation transparent to the host operating system Replacement Table A replacement table contains information regarding which devices have been replaced by others through standby replacement Rotated XOR Redundancy This term also known as parity or consistency data refers to a method of providing complete data redundancy while requiring only a fraction of the storage capacity of mirroring In a system configured under RAID 3 or RAID 5 which require at least three drives all data and parity blocks are divided between the drives in such a way that if any single drive is removed or fails the data on it can be reconstructed using the data on the remaining drives XOR ref
158. x Workstation Array Manager Navigating Global Array Manager Client or Workstation Array Manager Button Controls Dialog boxes throughout the Global Array Manager Client and Workstation Array Manager have a series of control buttons Some examples of these include 3 2 GAM Client v2 30 and WSAM User s Manual Startup amp Navigation Click this button to apply the settings made in the dialog box Click this button to cancel the settings made in the dialog box Yes Click this button to confirm the action identified in the dialog box Click this button to cancel the action identified in the dialog box Close Click this button to close the active dialog box Apply Click this button to apply your configuration changes Components of the GAM Opening Screen Upon startup with defined servers Global Array Manager Client displays the opening screen consisting of the Global Array Manager window the Global Status View window and the Log Information Viewer Figure 3 1 Global Array Manager ioli File View Administration Window Help 1 sl ai Servers gt imme DAcseosx z Global Status View 204 32 130 202 192 9 10 55 5 me _NT maces Ml mace 5 Sil E Log Information Viewer EventID Severity Source Source Time DeviceAddress Description Seq Local Time For Help press F1 7 Figure 3 1 Opening GAM Screen Manual No 771961 3 3 Navigating Globa
159. y e Disable by checking or enable by unchecking the following option e CC For Invalid LUN Disables the check condition affecting the handling of the Inquiry command when the referenced LUN is invalid 4 28 GAM Client v2 30 and WSAM User s Manual Configuration e Set the Host Bus Reset Delay Allows the controller to reset the host in failover and failback situations When Disabled no SCSI bus reset is generated on the host 4 generates reset this many seconds after the failover or failback occurs Immediate generates immediate reset with no delay This is host SCSI only e Set Debug Port Usage Select SLP VT100 emulation or Debug mode e Set Debug Port Speed Sets the baud rate for the serial port from 2400 to 19200 baud Manual No 771961 4 29 Setting and Modifying Controller Options Fibre Controller Options External Fibre Controllers Only The Fibre button only displays in the Controller Options dialog box when a Mylex Fibre Channel RAID Controller is currently selected Click the Fibre button in the Controller Options dialog box to inspect and or change Fibre options for External Fibre RAID Controllers These options should remain at their defaults unless you have a high degree of expertise with External Fibre RAID Controllers Fibre Controller Options 2 x m Hard Loop IDs IM Enable Node Name Retention PCI Latency Control Long d Frame Control 2KB ne M Controller 0 Port 0 l