Home
80 Bays SAS to SAS/SATA JBOD Subsystem User Manual
Contents
1. rrrmrsnsrssssrserersesrrerserrsrserseresesrnnns 47 3 4 Preparing the JBOD and Connecting to SAS HBA in Host System mserensrvenrrvrnersrserersrsrrserersenns 47 0 EEE EE 48 PN Oia oa 49 Chapter 4 Maintenance seessnnnvvnernnnvnnnennnnnnnvsnnnnnnnvsennnnnnvernnnnnnsennnnnnneennnnnnsennnnnnnnseee 50 E User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 4 1 Upgrading the JBOD Controller Firmware srarrsrvnvsnssrrnssssnssessnesesnensssesrenssssees 50 4 2 Replacing JBOD Subsystem ComponentS r mssnsrssrsesrvrrsrseveversrsrnensrsrnenensrsrnenenersrnsrsrserenersenenersrserersrsrsene 54 4 2 1 Replacing JBOD Controller MOdUle cc ccsssessssssssesssessesssessesessscsseseecssesssessssesesessesesesssseseaeeeesees 54 4 2 2 Replacing Power Supply Fan Module mrrvrvevrsensrserseserervessrsesesrrreserserseressrsesssseressrsessssenessnne 55 User Manual El 80 Bays SAS to SAS SATA BOD Subsystem Preface About this manual This manual provides information regarding the hardware features and installation of the 80Bay JBOD subsystem Information contained in the manual has been reviewed for accuracy but not for product warranty because of the various environment OS settings Information and specifications will be changed without further notice This manual uses section numbering for every topic being discussed for easy and convenient way of finding information in accordance with the user s needs The foll
2. N NOTE Be careful when inserting the 2 inner rails into the middle Rail Inner Rail Aligned with and Inserted into the Middle Rail User Manual 39 80 Bays SAS to SAS SATA J BOD Subsystem Important Make sure to hold the enclosure firmly in level position while inserting the enclosure in the rail Keep holding the enclosure moved inside the rack When the half rear side is inside the rack you can put down the two rear handles but support in the bottom part of the enclosure is still needed so that the enclosure will not drop down Rear handle ee SS se O s b s TE m a st E q Fw r eee Support in the bottom part of the enclosure 40 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 12 Press outwards the blue locks on both sides of the inner rail members at the same time Then push the enclosure inwards or backwards until it goes inside the rack Blue Lock of Inner Rail View from Right Side of Enclosure Blue Lock of Inner Rail is Pushed a Little Outwards and Enclosure is Pushed Inwards gt YT ALLL str LIL TT e View from Rear Side of Rack Cabinet Enclosure is Pushed I nwards User Manual PS 80 Bays SAS to SAS SATA BOD Subsystem 13 Use six 6 M5 screws to lock the enclosure into the rack post one screw in each corner Note that the screw driver will need to pass through the corner hole of front panel fo
3. Y COM1 115200baud Tera Term YT iol gt File Edit Setup Control Window Resize Help cm system upgrade Please Use XModem Protocol for File Transmission Use Q Or q to quit Download before starting XModem Expander ExpanderA ExpanderA Check Sum Success ExpanderA download fw success ExpanderB L ExpanderB ExpanderB Check Sum Success ExpanderB download fw success ExpanderC L ExpanderC ExpanderC Check Sum Success ExpanderC download fw success ExpanderD L ExpanderD ExpanderD Check Sum Success ExpanderD download fw success Received 364160Bytes Buffer Download Coria cmd gt 52 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 5 In command line type system info you can see the Expander firmware version W COM1 115200baud Tera Term YT File Edit Setup Control Window Resize Help cmd gt system info Expamder Expander Expander Expander Expander S L7Z2A S L7Z2A 5S 17Z2A MCU Date 2013 03 12 JOJO Expander ID PRO_MASTER Dual Control MASTER VendorID Proware Model EP 48 6JD S6S6 Build time Jul 3 2013 16 54 43 cmd Off User Manual 53 80 Bays SAS to SAS SATA BOD Subsystem 4 2 Replacing JBOD Subsystem Components 4 2 1 Replacing JBOD Controller Module When replacing a failed BOD Controller Module please follow these steps 1 Loosen the thumbscrews on the sides of the JBOD Controller Module drawer 2 Use t
4. SAS o ooo No need dongle board No need dongle board NOTE In this model it is recommended to use 6Gb s hard drive disks 2 6 1 To install a SATA disk drive Dual Controller Mode in a disk tray A HDD side brackets without dongle boards 1 Prepare the HDD side brackets Remove them from the dummy disk by pushing the upper sides of the dummy disk as shown below NE User Manual 80 Bays SAS to SAS SATA JBOD Subsystem a a a a a a 3 Connect the dongle board into the SATA disk drive User Manual 23 80 Bays SAS to SAS SATA BOD Subsystem 4 Place the brackets on both sides of the disk drive and secure them with screws 3 screws Or F6 32 UNC L 5 0mm F6 32 L 4 0mm for dongle board metal bracket 46 32 L 4 0mm for dongle board metal bracket 2 screws 6 32 UNC L 5 0mm 24 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem B HDD side brackets with dongle boards 1 Prepare the HDD side brackets Remove them from the dummy disk by pushing the upper sides of the dummy disk as shown below Hold the HDD side bracket and Pull outward to release side push the upper sides of the bracket from the dummy disk dummy disk 2 Place the brackets on both sides of the disk drive and secure them with screws User Manual 25 80 Bays SAS to SAS SATA BOD Subsystem K 4 4 4 3 screws Or H6 32 UNC L 5 0mm F6 32 L 4 0mm for dongle board metal bracket
5. SATA JBOD Subsystem 2 1 1 4 HDD Status LEDs The Front Panel shows the disk drives status Activity LED Power On Fail LED On Fail LED User Manual FE 80 Bays SAS to SAS SATA BOD Subsystem 2 1 2 Rear View Single Controller Power Supply 2 Power Supply 3 Power Supply 1 Power Supply 4 JBOD Controller FAN Module FAN Module Fan 9 Fan 10 Fan 11 Fan 12 Dual Controller Power Supply 2 Power Supply 3 Power Supply 1 Power Supply 4 JBOD Controller 1 JBOD Controller 2 Slave Expander 1 Slave Expander 2 14 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 2 2 JBOD Controller Module SAS IN Port Access LED System Ready LED Link LED Fault LED RS232 Port Mute SAS In Expansion Port R Link Port SAS In Expansion Port SAS In Expansion Port SAS IN Port SAS cable must be connected to this port and to the SAS HBA or other Expansion Chassis s SAS Expansion Port if this chassis is connected in daisy chain System Ready LED Green indicates Expansion Chassis is Powered On and Ready Fault LED Red LED is on indicates there is problem within the Expansion Chassis If LED is off the Expansion Chassis Is in normal condition RS 232 Port Used for upgrading the Firmware of BOD controller in the Expansion Chassis Mute Use this button to silence the alarm beeper If another failure event happens the alarm beeper will sound again and this button c
6. 1 Front View Main Switch Display Panel HDD Status Indicator IMPORTANT When powering off the J BOD subsystem turn off first the Main Switch last for more than 4 seconds and allow at least 4 minutes for the subsystem to shutdown properly Then turn off the switches of the 4 Power Supply Fan Modules NOTES The hot swap design allows for the replacement of front bezel without interrupting system operation User Manual og 80 Bays SAS to SAS SATA BOD Subsystem 2 1 1 1 LCD Panel Function Buttons Up and Down Use the Up or Down arrow keys to go through the information on the LCD screen This is also used to Arrow buttons move between each menu Select button w This is used to enter the option you have selected Press this button to return to the previous menu NOTE This button can also be used to silence the i alarm beeper when in main menu If you are in Exit button submenu and a failure event happens press the EXIT button few times as necessary to go back to main menu and press again to silence the alarm 10 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 2 1 1 2 LCD Display Panel LED Power LED Power Fail LED Fan Fail LED Over Temperature LED Voltage Warning LED Main Switch Reserved Parts Function Power LED Green indicates power is ON a If one of the redundant power supply unit fails Power FANER this LED will turn to RED and alarm will sound Turn RED when fan fa
7. 6 32 L 4 0mm for dongle board metal bracket 2screws 6 32 UNC L 5 0mm 26 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 2 6 2 To install a SAS disk drive Single or Dual Controller Mode or SATA disk drive Single Controller Mode in a disk tray 1 Prepare the HDD side brackets Remove them from the dummy disk by pushing the upper sides of the dummy disk as shown below User Manual Fl 80 Bays SAS to SAS SATA BOD Subsystem 2 Place the brackets on both sides of the disk drive and secure them with screws 3 screws 6 32 UNC L 5 0mm 4 2 screws 46 32 UNC L 5 0mm 3 Place the drive carefully in the disk slot ETS User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 4 Tighten the thumbscrews on the sides of the disk drive 5 L D N gt 80 Bays SAS to SAS SATA BOD Subsystem 5 Repeat the same steps for the rest of the disks Note The slot Number labels are included in the package Itis recommended to paste these labels on the hard disks to identify drives Slot 76 Note When installing the first column disks Slot 1 46 11 16 21 26 31 436 41 46 51 456 61 66 71 76 you need to release the subsystem from the rail by pushing white locks on both sides of the inner rail members at the same time 30 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem View from Right Side of Enclosure White
8. 80 Bays SAS to SAS SAT J BOD Subsystem User Manual 80 Bays SAS to SAS SATA BOD Subsystem Table of Contents Pee oe 4 Before You BEN 5 SES EET 1 E S EE EEE EE 5 Controller TN 5 Packaging Shipment ana DENN Laverne 5 Unpacking the Shipping Cart EEE 6 Chapter 1 Product IntroductiOn sseesnnvvvvvrrnnvvvverrnnnvnnvernnnnnnvennnnnnnnennnnnnsennnnnnseeenne 7 LL FONN 8 Chapter 2 Identifying Parts of the JBOD SubsystemM occconnnccoononccoconcccnnnnos 9 AE 260110 1 EE tai 9 12 VNR 9 2111 LCD VNR 10 2 LED Display PEN eier elit eres En Ene R 11 ALLS NTN 12 114 AMOD SINUS LEDS re aa e E E 13 12 PN 14 22 JBOD Controller MOGUIG EE EEE 15 23 Power Supply Fan Module PS EM arenaen 16 MN 18 EE EEE 19 EP 20 2 6 Disk Drive Installation into the Disk Slot sersrversrsrorrrsrversrsersrsersrsserersrnersrssrsrsersenserersrssrsersessensssenenenn 21 2 6 1 To install a SATA disk drive Dual Controller Mode in a disk tray cece 22 2 6 2 To install a SAS disk drive Single or Dual Controller Mode or SATA disk drive Single Controller Mode ma disk Tre 27 Chapter 3 Getting Started with the Subsystem ocooococcooconncnccnconnccnonconooss 33 3 1 Installing the Rails and MOUNTING into Rack m mmnvrvrnrrvrrrversrnrsrrrrserrnersrserenersrsenenerersenenessrsessesenenensrsennn 33 52 Removing the Disk Array from NE RACK enmascara 44 3 3 Preparing the JBOD and Connecting to RAID Subsystem
9. Lock of Inner Rail is Pushed a Little Outwards and Enclosure is Pushed Outwards Fe AA GE TIE Fs L 5 wa ra MEAE fee 5 feig ls I lg ETELA ee de z FOT ja im Ja in J User Manual E 80 Bays SAS to SAS SATA BOD Subsystem 6 Close the top cover by pressing the black locks 7 Then push the enclosure inwards or backwards until it goes inside the rack le ly User Manual dl N Lal pa 80 Bays SAS to SAS SATA JBOD Subsystem Chapter 3 Getting Started with the Subsystem 3 1 Installing the Rails and Mounting into Rack gt a NOTE At least two persons are needed to lift the Disk Array To reduce the weight of the Disk Array remove the power supply modules from the rear of Disk Array If disk drives are already installed in the disk trays remove also the disk trays Refer to appropriate sections on how to remove the power supply modules and how to remove the disk trays disk drives NOTE The sample model used in the following installation might not be the actual model for this manual NOTE The Disk Array must be installed near the Disk Array or host system where it will be connected A screwdriver is needed in installation 80 bay Disk Array because the total weight will not be supported by the rails N WARNI NG It is prohibited to put other enclosures on top of the Steps 1 Open the rail box 2 Remove the 2 rail assemblies and the s
10. PSFM is turned on the LED still shows RED After the main switch in front panel is turned on the LED turns GREEN which means it is functioning normally User Manual 17 80 Bays SAS to SAS SATA BOD Subsystem 2 4 Fan Module The 80bay JBOD subsystem contains 12 fans Fan 3 Fan 2 Fan 4 Fan 1 o i a 0606060 N EE EE EE ee ee eT o a 8 1440250 000500000000 0 0 aa LO Ce er F 1 a 13 ata es mr aa Lu a a fa ET aa 1 x E y 7 3 ee g ag a Fan 12 Fan 11 18 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 2 4 1 FAN Panel Fan 3 Fan 2 Fan 4 Fan 1 Fan 4 Fail LED Fan 1 Fail LED Fan 3 Fail LED Fan 2 Fail LED Fan 6 Fan 7 Fail LED Fan 6 Fail LED Fan 7 SN R Fan 8 Fail LED Fan 5 Fail LED ed FG MAT Fan 8 Fan 9 Fan 12 Fail LED Fan 10 Fan 11 Fail LED Fan 9 Fail LED Fan 12 Fan 10 Fail LED Fan 11 Indicates the fan is normal Fan Fail LED Indicates the turbo fail is faulty User Manual 80 Bays SAS to SAS SATA BOD Subsystem 2 5 Expander Module The 80bay JBOD subsystem contains Master and Slave Expander Modules The Expander Module contains the SAS expander It can be used to upgrade the SAS expander firmware It also contains the SES module SCSI Enclosure Services SES is the protocol used for enclosure environmental control The master expander module monito
11. an be pressed again to silence alarm R Link Port Use to connect to Telnet for upgrading the Firmware of BOD controller Link LED SAS IN and SAS Exp Green indicates SAS In Exp Port has connected or linked Access LED SAS IN and SAS Exp Blue indicates SAS In Exp Port is being accessed SAS Expansion Ports SAS cable must be connected to these ports and to other SAS IN Port of other expansion chassis for daisy chaining User Manual 15 80 Bays SAS to SAS SATA J BOD Subsystem 2 3 Power Supply Fan Module PSFM The 80bay JBOD subsystem contains four 650W Power Supply Fan Modules All PSFM are inserted at the rear of the chassis Power Supply 2 Power Supply 3 Power Supply 1 Power Supply 4 i o ETT in E ai magen n sere EE NOTE Each PSFM delivers Full Range 100V 240V 10 voltage AC electricity Each PSFM consists of 1 power supply and 1 fan 16 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem Power Status LED Fan Fail LED Power On Off Switch AC Power Input Socket Use to connect the power cord from power source Power On Off Switch Use to power on or power off the PSFM AC Power I nput Socket Power Status LED Red I ndicates the power supply module is faulty Fan Fa LED Red Indicates fan in the PSFM has failed When the power cord connected from main power source is inserted to the AC Power Input Socket the Power Status LED becomes RED When the switch of the
12. crews accessories from the box Check its contents i ED I of User Manual ES 80 Bays SAS to SAS SATA BOD Subsystem 3 Insert three 3 M5 nuts on the 2 holes of the front left side of the rack post Rack Post Front Left Side 4 Insert three 3 M5 nuts on the 2 holes of the front right side of the rack post Rack Post Front Right Side User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 5 Prepare the 2 rail assemblies Front Side of Rail Assembly Rear Side of Rail Assembly 6 Hold one rail assembly and install in the rear left side of rack Align and insert the 2 latches on the 2 holes on the rear rack post and then push the rail a little towards the rear side and lock the lock lever on the rack post 2 Latches are inserted in the 4 and 6 holes from bottom View from Rear Side of View from Rear Side of Rear Left Rack Post Rear Left Rack Post Lock Lever is Not Locked Lock Lever is Locked User Manual 35 80 Bays SAS to SAS SATA BOD Subsystem 7 Install the other end of rail assembly to the left front side To install align and insert the 2 latches of the rail into the 2 holes on the rack post Use the Lock Lever to lock the rail assembly in the left rack post View from Front Side of View from Front Side of Front Left Rack Post Front Left Rack Post Lock Lever is Not Locked Lock Lever is Locked 2 Latches View from Rear Side
13. ed on the LED still shows RED After the main switch in front panel is turned on the LED turns GREEN which means it is functioning normally Power Supply 2 Power Supply 3 Power Supply 1 Power Supply 4 AT TA OA 0E iT H Tila _ cm Soe 3 Push the main switch button in the front panel to power on Main Switch 48 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 3 6 Powering Off IMPORTANT When powering off the J BOD subsystem turn off first the Main Switch last for more than 4 seconds and allow at least 4 minutes for the subsystem to shutdown properly When J BOD subsystem has totally powered down turn off the switches of the 4 Power Supply Fan Modules at the rear User Manual 49 80 Bays SAS to SAS SATA BOD Subsystem Chapter 4 Maintenance 4 1 Upgrading the J BOD Controller Firmware IMPORTANT Before upgrade the J BOD firmware please shut down server first or make sure no array setting on the JBOD disks The new Firmware will effective after BOD power cycle NOTE Upgrading the firmware must be done from Master J BOD 5 Controller J BOD Controller 1 if the J BOD Subsystem has redundant J BOD Controllers The J BOD subsystem s factory default password is set to 00000000 Steps 1 Used RS 232 Port Phone jack to DB9 link SAS BOD in command line please type system upgrade than press Enter W COM1 115200baud Tera Term YT File Edit Setup Control Windo
14. harm on the part of the user and to obtain maximum performance user is advised to be aware of the following safety guidelines particularly in handling hardware components Upon receiving of the product Place the product in its proper location Do not try to lift it by yourself alone Two or more persons are needed to remove or lift the product to its packaging To avoid unnecessary dropping out make sure that somebody is around for immediate assistance It should be handled with care to avoid dropping that may cause damage to the product Always use the correct lifting procedures Upon installing of the product Ambient temperature is very important for the installation site It must not exceed 30 C Due to seasonal climate changes regulate the installation site temperature making it not to exceed the allowed ambient temperature Before plugging in any power cords cables and connectors make sure that the power switches are turned off Disconnect first any power connection if the power supply module is being removed from the enclosure Outlets must be accessible to the equipment All external connections should be made using shielded cables and as much as possible should not be performed by bare hand Using anti static hand gloves is recommended In installing each component secure all the mounting screws and locks Make sure that all screws are fully tightened Follow correctly all the listed procedures in this
15. he Controller handle to pull out the defective BOD Controller Module drawer 3 Insert and slide the new JBOD Controller Module in Note that it may be necessary to remove the old defective JBOD Controller Module from the drawer case and install the new one IMPORTANT When replacing a failed component online it is not OD recommended to remove the failed component for a long period of s time proper air flow within the enclosure might fail causing high controller disk drive temperature 4 Tighten the thumbscrews on the sides of the BOD Controller Module case 54 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 4 2 2 Replacing Power Supply Fan Module When replacing a failed power supply fan module PSFM please follow these steps Turn off the Power On Off Switch of the failed PSFM Disconnect the power cord from the AC Inlet Plug of PSFM Loosen thumbscrews of the PSFM Use the handle to pull out the defective PSFM Before inserting the new PSFM make sure the Power On Off Switch is on Off state eS IN YE 6 Insert and slide the new PSFM in until it clicks into place When replacing a failed component online it is not recommended to remove the failed component for a long period of time proper air flow within the enclosure might fail causing high controller disk drive temperature 7 Connect the power cord to the AC Inlet Plug of PSFM 8 Tighten the thumbscrews of the PSFM 9 Turn on the Po
16. hole of front panel for the two upper corner holes on both sides 6 Release the subsystem from the rail 46 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 3 3 Preparing the J BOD and Connecting to RAI D Subsystem 1 Install the disk drives if not yet installed Refer to Section 2 6 Disk Drive Installation for detailed information 2 Connect one end of SAS cable to the SAS In Port of the BOD subsystem enclosure and the other end to the SAS Expansion Port of the RAID subsystem enclosure 3 4 Preparing the J BOD and Connecting to SAS HBA in Host System 1 Install the disk drives if not yet installed Refer to Section 2 6 Disk Drive Installation for detailed information 2 Connect one end of SAS cable to the SAS In Port of the BOD subsystem enclosure and the other end to the SAS HBA on the Host system User Manual 47 80 Bays SAS to SAS SATA BOD Subsystem 3 5 Powering On 1 Plug in all the power cords into the AC Power Input Socket located at the PSFM GS NOTE The subsystem is equipped with redundant full range power supplies with PFC power factor correction The system will automatically select voltage 2 Turn on each Power On Off Switch of the PSFM The main switch button in the front panel will still flashing blue Lema NOTE When the power cord connected from main power source is inserted to the AC Power Input Socket the Power Status LED becomes RED When the switch of the PSFM is turn
17. ils or speed is lower than Fan Fail LED 3000 RPM If system backplane temperature is over 85 C or BP and disk temperatures exceed 55 C the Over Over Temperature LEDE Temperature LED will turn RED and alarm will sound Voltage Warning LED Indicates that the system is powering off The Flashing Blue main switch button will flash blue at least 4 minutes for the subsystem to shutdown properly Light Blue Indicates that the system is on No Light Indicates that the whole system is power off User Manual al 80 Bays SAS to SAS SATA BOD Subsystem 2 1 1 3 Menu Diagram Model Name F WVx x xx Temperature Power Status Good FAN Status Good Voltage Status Good Status Disabled 12 User Manual Temp01 30 C Temp10 30 C BP 30 C JBOD 30 C MA CPU 30 C MB CPU 30 C MC CPU 30 C MD CPU 30 C SA CPU 30 C SB CPU 30 C SC CPU 30 C SD CPU 30 C power 1 Good power 2 Good power 3 Good power 4 Good FANO1 3970rpm FAN12 3970 RPM BP 5V BP 3 3V BP 12V JBOD BP 5V J BOD BP 3 3V JBOD BP 12V M AB BP 5V M AB BP 3 3V M AB BP 12V M CD BP 5V M CD BP 3 3V M CD BP 12V S AB BP 5V S AB BP 3 3V S CD BP 5V S CD BP 3 3V 4 94V 3 2V 12 48V 4 94V 3 2V 12 48V 4 94V 3 2V 12 48V 4 94 V 3 2V 12 48V 4 94V 3 2V 4 94V 3 2V Disable Buzzer Enable Buzzer Only for dual JBOD controller Only for dual JBOD controller 80 Bays SAS to SAS
18. manual for reliable performance Controller Configurations This JBOD subsystem supports dual JBOD controller configurations Packaging Shipment and Delivery Before removing the subsystem from the shipping carton you should visually inspect the physical condition of the shipping carton Unpack and verify that the contents of the shipping carton are complete and in good condition Exterior damage to the shipping carton may indicate that the contents of the carton are damaged If any damage is found do not remove the components contact the dealer where you purchased the subsystem for further instructions User Manual so 80 Bays SAS to SAS SATA BOD Subsystem Unpacking the Shipping Carton The shipping carton contains the following JBOD Subsystem Unit 80 pairs of HDD side brackets Four 4 Power cords One 1 external SAS cable for single JBOD controller Note Two SAS cables for dual BOD controllers One 1 external serial cable for single JBOD controller Note Two serial cables for dual JBOD controllers Key of Top Cover Screws User Manual NOTE If any damage is found contact the dealer or vendor for assistance 6 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem Chapter 1 Product I ntroduction The 80 bays J BOD Subsystem The JBOD subsystem features the latest SAS2 6Gb s interface and designed to fit in with the environments which needed highly reliable a
19. nd relentless data growth It is also a versatile SAS2 SATA3 Disk Expansion system ideal for high capacity and scalability storage in IT demands Based on the 6G SAS2 0 technology it supporting the choice of SAS2 and SATA3 drive configurations to deliver the best cost performance index with higher bandwidth Features 80 hot swappable drive bays in a rackmount 4U chassis Simultaneously support SAS2 or SATA3 disk Single or dual SAS2 J BOD controller module Each SAS2 JBOD controller module consist of four mini SAS 4X port Modulize design of JBOD controller power supply and cooling system Four 650W high efficiency redundant hot swappable power supplies Incorporates a cableless design for maximum signal integrity Utilizes industry standard SCSI Enclosure Services to monitor enclosure and disk environmental conditions Enclosure monitoring User Manual ES S E S support for standard enclosure management System LED indications Fan speed monitoring Power supply monitoring System voltage monitoring System temperature monitoring System alarm 80 Bays SAS to SAS SATA J BOD Subsystem 1 1 Technical Specifications of Hot Swap Trays Disk Status Indicator 12 of Fans AC 90V 254V Full Range Power requirements 50Hz 60Hz Specification is subject to change without notice 8 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem Chapter 2 Identifying Parts of the J BOD Subsystem 2 1 Main Components 2 1
20. of Front Left Rack Post 2 Latches are inserted in the 4 and 6 holes from bottom M5 nut 36 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 8 Repeat step 6 to install the other rail assembly to the rack post of rear right side View from Rear Side of Rear Right Rack Post 9 Repeat step 7 to install the other rail assembly into the right front side Lower M5 nut View from Front Side of View from Front Side of Front Right Rack Post Front Right Rack Post Lock Lever is Not Locked Lock Lever is Locked User Manual 37 80 Bays SAS to SAS SATA BOD Subsystem 2 Latches Lower M5 nut View from Rear Side of Front Right Rack Post 2 Latches are inserted in the 4 and 6 holes from bottom M5 nut 10 Pull the 2 middle rail members out from the rail assembly Rear Right Side Front Right Side Middle Rail Member of Rail Assembly on Right Side of Rack 38 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem Front Side Right Front Side Left Front Side gt y SPORE ee a View from Rear Side 11 With at least 4 persons carrying the enclosure insert the 2 inner rails attached to the sides of the enclosure into the middle rails Slide the enclosure until it stops or about half way through rails The 2 inner rails must be parallel with the 2 middle rails so that 2 inner rails will insert and slide easily Use hands to guide the inner rails when inserted into the middle rails
21. owing icons are being used for some details and information to be considered in going through with this manual NOTES These are notes that contain useful information and tips that the user must give attention to in going through with the subsystem operation IMPORTANT These are the important information that the user must remember WARNING These are the warnings that the user must follow to avoid unnecessary errors and bodily injury during hardware and software operation of the subsystem CAUTI ON These are the cautions that user must be aware of to prevent damage to the subsystem and or its combonents Copyright No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent Trademarks All products and trade names used in this document are trademarks or registered trademarks of their respective owners Changes The material in this document is for information only and is subject to change without notice 4 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem Before You Begin Before going through with this manual you should read and focus on the following safety guidelines Notes about the subsystem s controller configuration and the product packaging and delivery are also included here Safety Guidelines To provide reasonable protection against any
22. r the two upper corner holes on both sides Front Left Side Front Right Side Y lp 8 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 14 Insert the power supply modules sg 4 Wes A Pa STE e aan M lhi 15 Open the top cover and re insert the disk drives disk trays if disk drives disk trays were previously removed Please refer to Section 2 6 Disk Drive Installation into the Disk Slot User Manual PES 80 Bays SAS to SAS SATA BOD Subsystem 3 2 Removing the Disk Array from the Rack 1 Remove the power supplies in the rear a Lu a E a El lt L 2 Remove the four screws in the front corner had a ME A EH i Front Left Side Front Right Side 44 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 3 Carefully pull the subsystem rr 4 Remove the disk drives from the disk slots Note When removing the first column disks Slot 1 6 11 16 21 26 31 36 41 46 51 56 61 66 71 76 you need to release the subsystem from the rail by pushing white locks on both sides of the inner rail members at the same time View from Right Side of Enclosure White Lock of Inner Rail is Pushed a Little Outwards and Enclosure is Pushed Outwards User Manual 45 80 Bays SAS to SAS SATA BOD Subsystem 5 Remove the two screws in the front corner Note that the screw driver will need to pass through the corner
23. rs the following enclosure conditions temperature power supply voltage and fan speed The slave expander module monitors the temperature and power supply voltage conditions Only for dual BOD controller oponi o Do Sao Pu A Slave Expander 1 Slave Expander 2 20 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 2 6 Disk Drive I nstallation into the Disk Slot This section describes the physical locations of the hard drives supported by the subsystem and give instructions on installing a hard drive NOTE When the Disk Array is shipped the disk trays are not placed in the disk slots If all disk trays will be used to install all 80 disk drives for quicker and easier installation of disk drives in the Disk Array it is recommended to attach first each disk drive with HDD side brackets and paste the slot number labels DISK SLOT NUMBERS Rear side peaje fan ee a a2 roo oe n gt a Lad al an sa ba an an ea ae 00 ha ha dl ba had ll dn ll ld Front Side NOTE The actual slot numbers according to the RAID Card or RAID Controller detection User Manual 21 80 Bays SAS to SAS SATA BOD Subsystem IMPORTANT In dual controller mode the installation of SATA disk drive in a disk tray is done differently In single controller mode the installation of SATA disk in a disk tray is the same with SAS disk CES Single Controller Dual Controller SATA No need dongle board Need dongle board
24. w Resize Help Password xXxxxxxxx cmd gt system upgrade Please Use XModem Protocol for File Transmission Use Q Or q to quit Download before starting XModem 50 User Manual 80 Bays SAS to SAS SATA JBOD Subsystem 2 Select Transfer amp Send File Select your firmware file path and select Xmodem in the communication protocol and click transfer button You must finish within 25 seconds JE File Edit Setup Control Window Resize Help New connection Alt N Duplicate session Alt D KKK Cygwin connection Alt G grade em Protocol for File Transmission Esmmenttoktoan quit Download before starting XModem View bog Show Log dlaleg s Send file Transfer Kermit SSH SCP XMODEM Change directory ZMODEM gt Replay Log B Plus A OA Y E Receive LogMeTT TTY Record TTY Replay Print Alt P Disconnect Exit Tera Term xMODEM send ea Look in fo S0bay 0 020 f GT gt f misas 0 020 80bay fu File name sas2afr 0 020 8Obay fw Open Files of type JAIN v Cancel Option fe Checksum cre C ik User Manual 51 80 Bays SAS to SAS SATA BOD Subsystem 3 Wait for the transfer of file to complete Tera Term XMDDEM Send xl Filename sasextw 0 020 80ba Protocol MODEM checksum Packet 492 Bytes transfered 62976 17 3 4 When the transfer and firmware update is complete please power cycle the J BOD
25. wer On Off Switch of the PSFM NOTE After replacing the Power Supply Fan Module and turning on a the Power On Off Switch of the PSFM the Power Supply will not power on immediately The Fans in the PSFM will spin up until the RPM becomes stable When Fan RPM is already stable the J BOD controller will then power on the Power Supply This process takes more or less 30 seconds This safety measure helps prevent possible Power Supply overheating when the Fans cannot work User Manual 55
Download Pdf Manuals
Related Search
Related Contents
Notice d`instruction Notice - Agence TDA MANUAL DE USUARIO SECRETARÍAS JR Direct XP8103 Satellite Radio User Manual Live Backup Manuel de déploiement 医療機器の添付文書の記載要領については Using the DeepSee Architect - InterSystems Documentation ProCAL User Manual Páginas Preliminares. Copyright © All rights reserved.
Failed to retrieve file