Home

User Manual

image

Contents

1. 6 Hold one rail assembly and install in the front left side of rack To install align and insert the 2 latches of the rail into the 2 holes on the rack post Use the Lock Lever to lock the rail assembly in the left rack post View from Front Side of Front Left Rack Post Lock Lever is Not Locked User Manual 35 64 Bays SAS to SAS SATA JBOD Subsystem View from Front Side of Front Left Rack Post Lock Lever is Locked ik A 2 Latches View from Rear Side of Front Left Rack Post 2 Latches are inserted in the 4 and 6 holes from bottom M5 nut 36 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 7 Install the other end of rail assembly to the left rear side Align and insert the 2 latches on the 2 holes on the rear rack post and then push the rail a little towards the rear side and lock the lock lever on the rack post Latches Latches View from Rear Side of Rear Left Rack Post User Manual 37 64 Bays SAS to SAS SATA JBOD Subsystem 8 Repeat step 6 to install the other rail assembly into the right front side 2ll Lock Lever i ke a Lower Wath af ia View from Front Side of Front Right Rack Post Lock Lever is Not Locked i i 4 r View from Front Side of Front Right Rack Post Lock Lever is Locked 38 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 2 Latches View from Rear Side of Front Right Rack Post 2 Latches are inserted
2. IMPORTANT When powering off the JBOD subsystem turn off first the Main Switch and allow at least 3 minutes during which each disk slot starting from slot 1 until slot 64 will be powered down for the subsystem to shutdown properly Then turn off the switches of the 2 Power Supply Fan Modules BET User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 2 1 1 1 LCD Display Panel LED m la ralrt Power LED Green indicates power is ON i Indicates that the power cords are inserted and or Flashing Blue ler i indicates the 2 power supply switches are turn on Light Blue Indicates that the sytem is on No Light Indicates that the whole system is power off User Manual T 64 Bays SAS to SAS SATA JBOD Subsystem 2 1 1 2 HDD Status LEDs The Front Panel shows the disk drives status Activity LED Power On Fail LED Indicates the disk drive in this slot is On Fail LED defective or failed Indicates there is no disk drive in this slot 012 User Manual 2 1 2 Rear View Single JBOD Controller Power Supply 01 1 JBOD Controller Fan 06 1 CG 1 C L24434 E f Expander 1 1 Dual JBOD Controller Power Supply 01 1 JBOD Controller 1 Fan 06 1 64 Bays SAS to SAS SATA JBOD Subsystem Power Supply 01 2 Expander 1 2 Power Supply 01 2 JBOD Controller 2 Expander 1 1 Expander 2 1 hardware monitoring Expander 2 2 Expander 1 2 NOTE Each Power Supply Module has 1 Power Su
3. modules from the rear of Disk Array If disk drives are already installed in the disk trays remove also the disk trays Refer to appropriate sections on how to remove the power supply modules and how to remove the disk trays disk drives NOTE The sample model used in the following installation might not be the actual model for this manual NOTE The Disk Array must be installed near the Disk Array or host system where it will be connected A Phillips screwdriver is needed in installation 64 bay Disk Array because the total weight will not be supported by the rails WARNING It is prohibited to put other enclosures on top of the Steps 1 Open the rail box 2 Remove the 2 rail assemblies and the screws accessories from the box Check its contents User Manual 33 64 Bays SAS to SAS SATA JBOD Subsystem 3 Insert three 3 M5 nuts on the 2 holes of the front left side of the rack post Position of M5 nuts on the 3 holes of left rack post Rack Post Front Left Side 4 Insert three 3 M5 nuts on the 2 holes of the front right side of the rack post Position of M5 nuts on the 3 holes of right rack post Rack Post Front Right Side 34 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 5 Prepare the 2 rail assemblies A Ad gt HR 2 o gt A U o e ere a gam jae 3 Ce be Ey E Front Side of Rail Assembly
4. Transfer gt Send File gt Browse 3 Open and select the rom file for example 8018 mfgdat12 20140822 rom firmware folder location Select Xmodem Protocol to send firmware file Only need about 60 seconds to finish sending firmware file If not please repeat steps E again Note If won t to transfer CFG data rom file Press Q or q to quit Download before starting data transfer g CLI gt fdl code Please Use XModem Protocol for File Transmission Use Q or q to quit Download before starting XModem h Select Functon menu to transfer firmware file Function Transfer 3 Send File gt Browse 3 Open and select the fw file for example 8018 03 B0 00 1F 20140822 fw from firmware folder location Select Xmodem Protocol to send firmware file Only need about 60 seconds to finish sending firmware file If not please repeat steps G again Note If won t to transfer firmware data fw file Press Q or q to quit Download before starting data transfer Use reset command to Restart JBOD or power cycle j Re login to JBOD CLI k Use sys command to verify JBOD firmware version CLI gt sys If needed the reset command can also be used to restart the JBOD controller Normally used in single JBOD Controller mode If already to connect to Controller CLI gt reset User Manual 53
5. Modules All PSFM are inserted at the rear of the chassis Front Panel Rear Side NOTE Each PSFM delivers Full Range 100V 240V 10 voltage AC electricity Each PSFM consists of 1 power supply and 5 fans Two Fans are located at the panel side and three fans are located in rear side of the PSFM BET User Manual 64 Bays SAS to SAS SATA JBOD Subsystem Power Supply 01 1 Power Supply 01 2 Fan 01 1 Fan0O2 1 Fan 01 2 Fan 02 2 Fan 04 1 Fan 03 1 m Fan 05 1 Ly A Rear Side 7 Fan 01 1 Front Panel Fan 02 1 fans Fan 01 1 and Fan 02 1 on the front panel and Fan 03 1 Fan 04 1 and Fan 05 1 on the rear side NOTE The first PSFM 01 1 on the left side of enclosure has five The second PSFM 01 2 on the right side has five fans also Fan 01 2 and Fan 02 2 on the front panel and Fan 03 2 Fan 04 2 and Fan 05 2 on the rear side NS NOTE 1 means enclosure 1 and 2 means enclosure 2 User Manual ETA 64 Bays SAS to SAS SATA JBOD Subsystem 2 3 1 PSFM Panel Power On Off Switch AC Power Input Socket Power Status LED Fan Fail LED Part Description O AC Power Input Socket Use to connect the power cord from power source Power On Off Switch Use to power on or power off the PSFM Indicator Color __ Description Indi h i i Power Status Green ndicates the power supply module is good LED Indicates the power supply module is faulty Fan Fail LED rea e
6. SAS to SAS SATA JBOD Subsystem Unpacking the Shipping Carton The shipping carton contains the following JBOD Subsystem Unit 64 pairs of HDD side brackets Two 2 Power cords One 1 external SAS cable mini SAS HD to mini SAS Note Two 2 SAS cables for dual JBOD controllers One 1 external serial cable RJ11 to DB9 for single JBOD controller Note Two 2 serial cables for dual JBOD controllers One 1 Disk Tool Key of Top Cover User Manual 64 Bays SAS to SAS SATA JBOD Subsystem Screws User Manual _ NOTE If any damage is found contact the dealer or vendor for assistance ser Manual DE 64 Bays SAS to SAS SATA JBOD Subsystem Chapter 1 Product Introduction The 64 bays JBOD Subsystem The JBOD subsystem is a 19 inch 4U rackmount JBOD unit It is a versatile SAS2 SATA3 disk expansion system ideal for high capacity and scalability storage in IT demands It offers high density storage hardware redundancy and easily integrates into versatile applications that request high performance and high scalability This JBOD subsystem comes with either dual or single JBOD controller configuration for options It features a modular architecture for all key components which ease system maintenance and management Highest Density Available 4U chassis with 64 bays carriers Support the 2 5 3 5 enterprise class SAS2 SATA3 HDD drives High Availability Single or dual SAS J
7. can put down the two rear handles but support in the bottom part of the enclosure is still needed so that the enclosure will not drop down o 42 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem a3 i i i e i i i i i i View from Rear Side 12 Press outwards the blue locks on both sides of the inner rail members at the same time Then push the enclosure inwards or backwards until it goes inside the rack Blue Lock of Inner Rail View from Right Side of Enclosure Blue Lock of Inner Rail is Pushed a Little Outwards and Enclosure is Pushed Inwards User Manual PER 64 Bays SAS to SAS SATA JBOD Subsystem B amp E i E L E E E B US im Ei i B d EH mi ms tw at View from Rear Side of Rack Cabinet Enclosure is Pushed Inwards 13 Insert the power supply modules 5 EEEH 7 erry 9 o 44 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 14 Use six 6 M5 screws to lock the enclosure into the rack post one screw in each corner Note that the screw driver will need to pass through the corner hole of front panel for the two upper corner holes on both sides Front Left Side Front Right Side 15 Open the top cover and re insert the disk drives disk trays if disk drives disk trays were previously removed Then close the top cover User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 3 2 Removing the Disk Array from the Rack 1
8. side brackets DISK SLOT NUMBERS Rear side 57 37 17 Front Side User Manual 23 64 Bays SAS to SAS SATA JBOD Subsystem IMPORTANT In dual controller mode the installation of SATA disk drive in a disk tray is done differently In single controller mode the installation of SATA disk in a disk tray is the same with SAS disk H Single Controller Dual Controller SAA No need dongle board Need dongle board No need dongle board No need dongle board NS NOTE In this model it is recommended to use 6Gb hard drive disks 2 6 1 To install a SATA disk drive Dual Controller Mode in a disk tray A HDD side brackets without dongle boards 1 Prepare the HDD side brackets Remove them from the dummy disk by pushing the upper sides of the dummy disk as shown below 24 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem a a a a a a a a a q a a Connect the dongle board into the SATA disk drive User Manual 25 64 Bays SAS to SAS SATA JBOD Subsystem 4 Place the brackets on both sides of the disk drive and secure them with screws a Jr amp aaan a uae a e nann a ma mmm oy 7 2 screws JE 6 32 UNC L 5 0mm i 6 32 L 4 0mm for dongle board metal bracket on renen ene ane smst fore Tl ee 6 32 L 4 0mm 2 screws for dongle board metal bracket 6 32 UNC L 5 0mm 26 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem B HDD s
9. the enclosure Turbo Fan LED Status LED NOTE The status of Turbo Fan Fan 06 1 is monitored by Expander Module 1 User Manual 21 64 Bays SAS to SAS SATA JBOD Subsystem 2 5 Expander Module The Expander Module contains the SAS expander It can be used to upgrade the SAS expander firmware It also contains the SES module SCSI Enclosure Services SES is the protocol used for enclosure environmental control The SES module monitors the following enclosure conditions temperature power supply voltage and fan speed 2 5 1 Expander Module Panel Activity LED RS 232 Port Oo y el Fault LED S OO Use to upgrade the firmware of the expander module Connect the serial cable RJ11 to DB9 to your system s serial port Activity LED Blinking Indicates the expander module is busy or Green active Fault LED Binking Indicates the expander module is faulty or Blue has failed 22 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 2 6 Disk Drive Installation into the Disk Slot This section describes the physical locations of the hard drives supported by the Subsystem and give instructions on installing a hard drive NOTE When the Disk Array is shipped the disk trays are not X placed in the disk slots If all disk trays will be used to install all 64 disk drives for quicker and easier installation of disk drives in the Disk Array it is recommended to attach first each disk drive with HDD
10. 64 Bays SAS to SAS SATA JBOD Subsystem User Manual 64 Bays SAS to SAS SATA JBOD Subsystem Table of Contents Prela oe nee ee er rere ere 4 Before You BGO ie cscccceccececcccnscesccncecorececeasteserecesecececatenecessssesencutececenssvecaunnecnscesateneaeaeees 5 STEN AV ae G01 AE A vO oon EA enn A ee nn ee oP E 5 Controller Config ratiONS s sorsi onain aa Tona ai Sesa Taa da aad o a E a Ea E aE ai io 5 Packaging Shipment and Delivery nu cceecessssessesesessecsesessessesessessesussessecucsessesucsessecussessesucsessecnssesseeueseeseencsesseenesesseenes 5 Unpacking the Shipping Carton cecccsessessesessessesesssssesssessessssessesessessssussessessssessessssessessssesseenssesssenssesseeneseeseenes 6 Chapter 1 Product INtroduction scccsssssccccsssssscccssssscccessssscccessssecsesssssseeeees 8 LT o er es perea ON ene enone mee ene nee nT Her on ern ge SP RCN nO een nee EET EDR ENTRE 9 Chapter 2 Identifying Parts of the JBOD Subsystem M WuuWu ssssvesseevsseeeeseeees 10 AL Man og g ERE SS ener ene ee reer eee E A eee ree eee eee eer 10 edL FROME VION oeer E ce ee eee 10 ELEL LCP pay PR REED SE nn tr nen ene ere 11 PA AVD Shas LED src ate erent eee eee ee 12 Zid IRCA WW E E rr 13 22 JBOD Controller Mod le 2 cedar eter eds case ccaeeped aa seenen nS censors ees etseas eae ENA GSK ceric ees 15 2 3 Power Supply Fan Module PSFM seaescaseceectecaactectcccecesccaactest re err senere ner er
11. BOD controller module Each SAS JBOD controller module consist of three 4x mini SAS HD ports Power Supply Power supply and cooling system contained in 1 module for efficient cooling Two 1100W redundant hot swappable power supplies Enclosure Incorporates a cableless design for maximum signal integrity Utilizes industry standard SCSI enclosure services SES to monitor enclosure and disk environmental conditions Enclosure monitoring S E S support for standard enclosure management System LED indications Fan speed monitoring Power supply monitoring System voltage monitoring System temperature monitoring System alarm BES User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 1 1 Technical Specifications JBOD Controller Single Redundant Host Interface One 4x mini SAS HD 12Gb s Two 4x mini SAS HD 12Gb s Disk Interface 6Gb s SAS 6Gb s SATA SAS expansion Two 4x mini SAS HD 12Gb s Four 4x mini SAS HD 12Gb s Form Factor Tray Lock Disk Status Indicator Access Fail LED Backplane SAS SATA Single BP of PS Fan Modules 1100W x 2 w PFC of Fans Power requirements AC 90V 254V Full Range 50Hz 60Hz Specification is subject to change without notice User Manual 9 64 Bays SAS to SAS SATA JBOD Subsystem Chapter 2 Identifying Parts of the JBOD Subsystem 2 1 Main Components 2 1 1 Front View ee ee Ba e 00e os a Main Switch Display Panel HDD Status Indicator
12. M1 Port or change to other COM Port as necessary 2 Open Windows HyperTerminal Program Connect using COM1 COM Port used in Step1 Baud Rate 115200 n 8 1 Flow Control None 3 Press the Enter key and the password prompt will be displayed 4 Key in the password Default password 00000000 to login to CLI 5 At CLI prompt input the command to update firmware a CLI gt mo Operation Mode Master CLI Dual M Sensor I2C Operation Mode Backup Operation Mode Single NOTE If Operation Mode is Master CLI Dual M Sensor I2C it means you are connected to Master Expander and you can continue with next steps If Operation Mode is Backup it means you are connected to Backup Expander Remove RS232 serial cable and insert to other JBOD RS232 Port If Operation Mode is Single it means this JBOD subsystem has only one controller please skip to step D b CLI gt mo fdl both c CLI gt mo Operation Mode Master CLI Dual M Sensor I2C fdl both 52 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem d CLI gt NOTE fdl code is the command to update flash firmware code fw file fdl mfgb is the command to update CFG data code rom file Make sure you have both files before updating e CLI gt fdl mfgb Please Use XModem Protocol for File Transmission Use Q or q to quit Download before starting XModem f Select Function menu to transfer CFG data rom file Function 3
13. Remove the six screws in the front corner Front Left Side Front Right Side 2 Remove the power supplies in the rear and the disk drives from the disk slots SE Ce a 2 SOREL Ee TR eT ae eT ee 46 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 3 Carefully pull the subsystem J53 i i i t i i i i i i 4 Push the white lock to release the subsystem from the rail User Manual 47 64 Bays SAS to SAS SATA JBOD Subsystem 3 3 Preparing the JBOD and Connecting to RAID Subsystem 1 Install the disk drives if not yet installed Refer to Section 2 6 Disk Drive Installation for detailed information 2 Connect one end of SAS cable to the SAS In Port of the JBOD subsystem enclosure and the other end to the SAS Expansion Port of the RAID subsystem enclosure 3 4 Preparing the JBOD and Connecting to SAS HBA in Host System 1 Install the disk drives if not yet installed Refer to Section 2 6 Disk Drive Installation for detailed information 2 Connect one end of SAS cable to the SAS In Port of the JBOD subsystem enclosure and the other end to the SAS HBA on the Host system 48 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 3 5 Powering On 1 Plug in all the power cords into the AC Power Input Socket located at the PSFM x a NOTE The subsystem is equipped with redundant full range power supplies with PFC power factor correction The system will automa
14. a one or more fans in the PSFM has When the power cord connected from main power source is inserted to the AC Power Input Socket the Power Status LED becomes RED When the switch of the PSFM is turned on the LED still shows RED After the main switch in front panel is turned on the LED turns GREEN which means it is functioning normally The PSFM has a 5V standby DC voltage When the power cord s is are connected to the AC Power Input Socket after 1 second all Activity LEDs will flash once When the power cord s is are disconnected from AC Power Input Socket after 3 seconds all Activity LEDs will flash twice 18 use vera 64 Bays SAS to SAS SATA JBOD Subsystem 2 4 Fan Module The 64bay RAID subsystem contains 15 fans Power Supply 01 1 Power Supply 01 2 Turbo Fan 06 1 Fan O1 1 Fan0O2 1 Fan 01 2 Fan 02 2 Fan 04 1 Fan 03 1 p Fan 05 1 A Ly Fan 01 1 Fan 02 1 mk NOTE 1 means enclosure 1 and 2 means enclosure 2 User Manual 19 64 Bays SAS to SAS SATA JBOD Subsystem Rear Side aa Power Supply 2 Power Supply 1 Fan 03 2 Fan 05 1 Fan 04 2 i Fan 04 1 Fan 05 2 Fan 03 1 Fan Fault LED Fan 07 2 Fan 07 1 Fan 06 2 Fan 08 1 Front Side No rignt Indicates the fan is normal Fan Fault LED rea Indicates the turbo fail is faulty User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 2 4 1 Turbo Fan The turbo fan Fan 06 1 provides additional airflow inside
15. ere 51 FE User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 4 1 Upgrading the JBOD Controller Firmware u ccecccsessssesssssssesesssssessssessssesssssssessesseesssesssssssesseesesesseeseasaes 51 User Manual 3 64 Bays SAS to SAS SATA JBOD Subsystem Preface About this manual This manual provides information regarding the hardware features and installation of the 64Bay JBOD subsystem Information contained in the manual has been reviewed for accuracy but not for product warranty because of the various environment OS settings Information and specifications will be changed without further notice This manual uses section numbering for every topic being discussed for easy and convenient way of finding information in accordance with the user s needs The following icons are being used for some details and information to be considered in going through with this manual NOTES X These are notes that contain useful information and tips that the user must give attention to in going through with the subsystem operation IMPORTANT These are the important information that the user must remember WARNING A These are the warnings that the user must follow to avoid unnecessary errors and bodily injury during hardware and software operation of the subsystem CAUTION These are the cautions that user must be aware of to prevent damage to the subsystem and or its components Copyright No part of this publicat
16. f first the Main Switch in the front panel and allow at least 3 minutes for the subsystem to shutdown properly During this time each disk slot starting from slot 1 until slot 64 will be powered down The main switch button in the front panel will flash blue When JBOD subsystem has totally powered down turn off the switches of the 2 Power Supply Fan Modules at the rear The main switch button in the front panel will still flash blue until the power cords are pulled out from the sockets 50 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem Chapter 4 Maintenance 4 1 Upgrading the JBOD Controller Firmware oa NOTE The JBOD firmware upgrade procedure must be done three times First is on the JBOD Controller next is on the Expander Module 1 1 then last on the Expander Module 1 2 NOTE There must be no I O in the disk drives in the JBOD subsystem RAID volumes should not be accessed during firmware upgrade Power Supply 01 1 JBOD Module 2 JBOD Module 1 Power Supply 01 2 Expander 2 2 Expander 1 1 Expander 2 1 Expander 1 2 Fan 06 1 User Manual ERE 64 Bays SAS to SAS SATA JBOD Subsystem NS NOTE It is important to stop I O access to JBOD subsystem during firmware upgrade NOTE Upgrading the firmware must be done from Master JBOD Controller if the JBOD Subsystem has redundant JBOD Controllers 1 Please use the RS232 cable RJ11 to DB9 to JBOD Controller 1 and to connect JBOD RS232 Port and PC CO
17. ide brackets with dongle boards 1 Prepare the HDD side brackets Remove them from the dummy disk by pushing the upper sides of the dummy disk as shown below User Manual 27 64 Bays SAS to SAS SATA JBOD Subsystem 2 Place the brackets on both sides of the disk drive and secure them with screws 2 screws 6 32 L 4 0mm 2 screws for dongle board metal bracket 6 32 UNC L 5 0mm 28 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 2 6 2 To install a SAS disk drive Single or Dual Controller Mode or SATA disk drive Single Controller Mode in a disk tray 1 Prepare the HDD side brackets Remove them from the dummy disk by pushing the upper sides of the dummy disk as shown below User Manual 29 64 Bays SAS to SAS SATA JBOD Subsystem 2 Place the brackets on both sides of the disk drive and secure them with screws 2 screws Ba 6 32 UNC L 5 0mm N 2 screws 6 32 UNC L 5 0mm 30 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 3 Place the drive carefully in the disk slot User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 4 Fix the disk drive using the disk tool that is included in the package 64 Bays SAS to SAS SATA JBOD Subsystem Chapter 3 Getting Started with the Subsystem 3 1 Installing the Rails and Mounting into Rack NOTE At least two persons are needed to lift the Disk Array To Y reduce the weight of the Disk Array remove the power supply
18. in the 4 and 6 holes from bottom M5 nut 9 Repeat step 7 to install the other end of rail assembly to the rack post of rear right side View from Rear Side of Rear Right Rack Post User Manual 39 64 Bays SAS to SAS SATA JBOD Subsystem Latches i a 19U View from Rear Side of Rear Right Rack Post 40 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 10 Pull the 2 middle rail members out from the rail assembly Front Left Side TAMA R EEsERE Rear Left Side Middle Rail Member of Rail Assembly on Left Side of Rack Front Side Right Front View from Rear Side User Manual aoo 64 Bays SAS to SAS SATA JBOD Subsystem 11 With at least 4 persons carrying the enclosure insert the 2 inner rails attached to the sides of the enclosure into the middle rails Slide the enclosure until it stops or about half way through NOTE Be careful when inserting the 2 inner rails into the middle rails The 2 inner rails must be parallel with the 2 middle rails so that 2 inner rails will insert and slide easily Use hands to guide the inner rails when inserted into the middle rails Inner Rail Inner Rail Aligned with and Inserted into the Middle Rail Important Make sure to hold the enclosure firmly in level position 1 while inserting the enclosure in the rail Keep holding the enclosure moved inside the rack When the half rear side is inside the rack you
19. ion may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent Trademarks All products and trade names used in this document are trademarks or registered trademarks of their respective owners Changes The material in this document is for information only and is subject to change without notice 4 User Manual 64 Bays SAS to SAS SATA JBOD Subsystem Before You Begin Before going through with this manual you should read and focus on the following Safety guidelines Notes about the subsystem s controller configuration and the product packaging and delivery are also included here Safety Guidelines To provide reasonable protection against any harm on the part of the user and to obtain maximum performance user is advised to be aware of the following safety guidelines particularly in handling hardware components Upon receiving of the product Place the product in its proper location Do not try to lift it by yourself alone Two or more persons are needed to remove or lift the product to its packaging To avoid unnecessary dropping out make Sure that somebody is around for immediate assistance It should be handled with care to avoid dropping that may cause damage to the product Always use the correct lifting procedures Upon installing of the product Ambient temperature is ve
20. ne etter treerne retn rer rss enn neg 16 Dede POPNE PIRO heats caesar E E AEAEE E EEEE ERE ENE 18 2A Fan MOUE aeee EEE EAIA AEE E E OA AA 19 2AL TODO F A E E EEEE E E E A E 21 P S gt 0 late lt a Module aoea E E A EE E 22 251 Expander Module Panel ssssesreiseseissereseienienesdee aiie eee ee ee 22 2 6 Disk Drive Installation into the Disk SlOt ec sssssssessssssssssesssssssssssssssssssessecsssessssssssssssssesesseeseeseesseses 23 2 6 1 To install a SATA disk drive Dual Controller Mode in a disk tray uXuXuu u nndssssccesesrrtsrsrreeee 24 2 6 2 To install a SAS disk drive Single or Dual Controller Mode or SATA disk drive Single Controller Mode in a disk tray ccececsesessessecsssssesscsessessssessesscsesseescsessessesesseesesussessesussessessseesessseeseeesseeseeesseenee 29 Chapter 3 Getting Started with the Subsystem ooeessoooeessooeesssooeesssoesessoo 33 3 1 Installing the Rails and MOUNTING into RACK wo ccssessesessessessesessesseseesessssesseesesesseeseseseeseeesseeseeneees 33 3 2 Removing the Disk Array from the Rack u cccccccssessssessessessessesscsssessessessesssssessssessesseesessessesseeneseeseeseeseenee 46 3 3 Preparing the JBOD and Connecting to RAID Subsystem 0 ce cesesesteseesessesesseesesesseesestsseeseeeses 48 3 4 Preparing the JBOD and Connecting to SAS HBA in Host System uu cceeseseseesesseeteseeseeeeee 48 Ja FONINI EEEE noe ve REE 49 BO CV TIN EET A 50 Chapter 4 Ye LU 01 6 ee eee eee eee eee
21. pply and 5 Fans The JBOD subsystem is logically divided into two enclosures for User Manual a3 64 Bays SAS to SAS SATA JBOD Subsystem The functions of the Expander Modules are as follows Monitors Enclosure 1 Disk slots 1 to 32 Power Supply 01 1 Fans Expander Module 1 1 01 1 02 1 03 1 04 1 and 05 1 07 1 08 1 and Turbo Fan 06 1 Note 1 means enclosure 1 Expander Module 2 1 Same function as Expander 1 1 for Controller 2 Monitors Enclosure 2 Disk slots 33 to 64 Power Supply 01 2 Expander Module 1 2 Fans 01 2 02 2 03 2 04 2 05 2 06 2 and 07 2 Note 2 means enclosure 2 Expander Module 2 2 Same function as Expander 1 2 for Controller 2 ery User Manual 64 Bays SAS to SAS SATA JBOD Subsystem 2 2 JBOD Controller Module SAS In Port Reserved Link LED SAS Expansion Port RS 232 Port Use to connect to SAS HBA or to RAID subsystem s SAS Expansion Port SAS Expansion Port Use to connect to the SAS In Port of another P JBOD subsystem Use to upgrade the firmware of the JBOD controller Connect the RJ11 to DB9 serial cable to your system s serial port Kr Link LED Green Indicates expander has connected or linked Activity LED Blinking Indicated the expander is busy and being Blue accessed User Manual a5 64 Bays SAS to SAS SATA JBOD Subsystem 2 3 Power Supply Fan Module PSFM The 64bay RAID subsystem contains two 1100W Power Supply Fan
22. ry important for the installation site It must not exceed 30C Due to seasonal climate changes regulate the installation site temperature making it not to exceed the allowed ambient temperature Before plugging in any power cords cables and connectors make sure that the power switches are turned off Disconnect first any power connection if the power supply module is being removed from the enclosure Outlets must be accessible to the equipment All external connections should be made using shielded cables and as much as possible should not be performed by bare hand Using anti static hand gloves is recommended In installing each component secure all the mounting screws and locks Make sure that all screws are fully tightened Follow correctly all the listed procedures in this manual for reliable performance Controller Configurations This JBOD subsystem supports single JBOD controller configurations Packaging Shipment and Delivery Before removing the subsystem from the shipping carton you should visually inspect the physical condition of the shipping carton Unpack and verify that the contents of the shipping carton are complete and in good condition Exterior damage to the shipping carton may indicate that the contents of the carton are damaged If any damage is found do not remove the components contact the dealer where you purchased the subsystem for further instructions User Manual ERE 64 Bays
23. tically select voltage a NOTE The PSFM has a 5V standby DC voltage When the power N cord s is are connected to the AC Power Input Socket after 1 second all Activity LEDs will flash once When the power cord s is are disconnected from AC Power Input Socket after 3 seconds all Activity LEDs will flash twice 2 Turn on each Power On Off Switch of the PSFM The main switch button in the front panel will still flashing blue NOTE When the power cord connected from main power source is inserted to the AC Power Input Socket the Power Status LED becomes RED When the switch of the PSFM is turned on the LED still shows RED After the main switch in front panel is turned on the LED turns GREEN which means it is functioning normally e Power Supply 01 1 Power Supply 01 2 gt 4 ers aes User Manual a9 64 Bays SAS to SAS SATA JBOD Subsystem 3 Push the main switch button in the front panel to power on Main Switch 4 Allow the machine a few moments to initialize before using it The main switch button will continue flashing blue until the system is finished checking each disk Slot NOTE The system will initialize after turning on the Main Switch Each disk slot will be checked during subsystem initialization 5 Configure JBOD subsystem using the utility options described in the next chapter 3 6 Powering Off IMPORTANT When powering off the JBOD subsystem turn of

Download Pdf Manuals