E1 - AD-net Technology Co., Ltd.

image

Contents

1. AD NET TEHCNOLOGY CO LTD 10 100 1 Converter MODEL AN E1 ETH USER MANUAL 1 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO LTD TABLE OF CONTENTS GENERAL INFORMATION PRODUCT CHARACTERISTIC ENVIRONMENT REQUIREMENT 3 1 Power 3 2 Power consumption 3 3 E1 Interface 3 4 10 100Base T Interface DIMENSIONS CONFIGURATION AND OPERATION 5 1 Display of the front panel 5 2 Button switch 5 3 Display of the rear panel 5 4 Dial code in the panel 5 5 Description of E1 connector PACKING 6 1 Packing pattern 6 2 Power Installation NETWORK APPLICATION MALFUNCTION DIAGNOSES AND ELIMINATION 2 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO LTD To Customer Thanks for using AD NET TECHNOLOGY product This manual provides most of the information please do read up the technical setup and safe keep the manual for future usage 3 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO LTD 1 GENERAL INFORMATION Model E1 F is a single port E1 with Ethernet Bridging that provides high speed LAN to WAN connectivity Plugging directly into the 10 100Base T port of a hub or LAN switch the E1 F provides E1 access at connection data rates of 2 048 Mbps The E1 F is an excellent choice for internet access as well as LAN to LAN services 2 PRODUCT CHARACTE
2. E d 4 x Loop 1 Loop 2 When testing one of above loop back must be on Push the PATT button when loop circuit 1 is on If PTOK is on indicates device works well loop circuit 1 off and loop circuit 2 on indicates that fiber transmission circuit and both side device work well Note B when the test LED on the normal communication will be terminated During the PATT model testing the circuit should be cycle by itself otherwise the PATT code can t come back 5 4 Display of the rear panel PHRRAQQJ 12345678 6703 el a 120 hore EX HUB HREERBEHERBH TX E1 750 unbalance Transmit BNC Interface 9 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO LTD RX E1 750 unbalance Receive BNC Interface 10 100Base T 10 100Base T Interface RJ45 120Q E1 E1 1200 Balance Interface RJ45 5 5 Dial code in the panel On the panel there are 8 digital dial code switches to set E1 clk 1 E1 CLK SET 2 LAN MODE SET 12345678 3 ETHERNET RESET 4 8 REMAIN 1 clk1 E1 master clk and line clk set E1 clk set Clk1 Master master clk OFF Slave line clk ON Note pls during communicating one master and one slave is necessary and the rate of the slave will follow the master 10 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO
3. 2 Power consumption Total power consumption lt 5W 5 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO LTD 3 3 E1 Interface Line Rate 2 048Mbps 50ppm Line Code HDB3 Interface Standard ITU T G 703 1 Impedance 75Q unbalance and 120Q balance Connections dual coax and 120 ohm twisted pair RJ45 Jitter tolerance finer than G742 and G 823 3 4 10 100Base T Interface Rate 10 100M full duplex auto negotiation Protocol Support IEEE 802 3 IEEE 802 1Q VLAN MAC Address Entiries 4096 Entiries Total Memory Sizes 64MBits SDRAM Physical interface RJ45 support AUTO MDIX 4 DIMENSIONS 210 W x 140 L x 30 H mm 5 CONFIGURATION AND OPERATION 6 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO LTD 5 1 Display of the front panel BIG EMTA DATA LINK LOS LOF TEST PTOK PWR OOOO ooooooo L on oF J 5 2 LED Indicator DATA Yellow wink signifying data receive or transmit in LAN LINK Active Green signifying a valid 10 100BaseT connection LOS Active Red signifying E1 signal Lost LOF Active Red signifying E1 Frame lost PTOK Active Green signifying PBRS check OK TEST Active Yellow signifying Device is on test status PWR Have two status Green Power is on Salmon pink signifying device is control by Netman DIP and Push Switch is unused Caution there may be some mi
4. LTD 2 clk2 LAN set 2 10 100M full duplex auto negotiation OFF 10M full duplex auto negotiation ON NOTE B f clk mode is salve rate of the device will follow the master 5 6 Description of E1 connector E1 connector 75Q RX 750 unbalance receive 75Q TX 750 unbalance transmit out 1200 1 1200 balance receive and transmit 2 TX E1 TXD 3 TX E1 TXD 6 RX E1 RXD 7 RX E1 RXD 12345678 14 58 is NC E1 Interface impedance set The push button sets E1 impedance 11 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO LTD impedance Button 1200 Push UP 750 Push Down LAN Interface In the back panel there are two RJ45 jack one is for DTE mode MDI the other is for DCE mode MDIX easy for you to use it PC Net Card or HUB or SWITCH Ww MDI MDIX 12345678 S Se To Node To HUB 12345678 2 Www MDI MDIX Converter LAN RJ45 45278 4 1 3 6 PACKING 6 1 Packing pattern The following are things listed in each package E1 10 100BT Converter 1 Power Line 220AC 1 User s manual 1 12 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO LTD BNC 2 6 2 Power Installing Power of AC220V DC 48V is suitable for the device If the power of DC 48V is used the positive and negative terminal can
5. into the ON Produce and transmit the PBRS codes into the input connector the LAN and confirm whether the output signal from the LAN accords the PATT standard by this way it can test the periphery circuit setting and device 2 1 PATT button set into ON and ask for the data loop back from opposite side to this side If the light of PTOK is off it means the fiber circuit has some problems 2 2 PATT button set into ON the light of PTOK off and ANA button set into ON at that time if the light of PTOK on it means that the Converter work well 2 3 PATT button set into on PTOK light off and press the REM or set the DIG button of the remote device on at that time if the PTOK light on it means that the both of the device and E1 Line circuit work well 14 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1
6. RISTIC Based on self copyright IC Ethernet port 10 100M half full duplex self adaptable supporting VLAN RJ45 interface supports AUTO MDIX Provides 2 clock types E1 master clock E1 line clock Provide LAN auto reset function run more stably Has the function of pseudo random code testing convenient for opening of the circuit and can be used as an error code instrument Have three LoopBack Modes E1 interface LoopBack ANA LAN interface LoopBack 016 command the remote LAN interface LoopBack REM 75 ohm dual coax and 120 ohm twisted pair G 703 connections provided only push the switch at the back panel of the device to adjust it 4 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO LTD With abundant presentation function of Ethernet data can detect real time data communication status B Can realize SNMP management 3 ENVIRONMENT REQUIREMENT The temperature requirement is not very strict the device can be working well under terrible environment working temperature 0 C 50 C relative humidity 95 without coagulation No erosive and impregnant gas no rising dust no strong magnetic field disturbing 3 1 Power Adapting module power voltage range can be wide with strong ant jamming function With good insulation stable working status is available B power 48V type input voltage 36 72 B power 220V type input voltage 175V 250V 3
7. be optional because there is the self test circuit for the polarity inside the optical modem 7 MALFUNCTION DIAGNOSES AND ELIMINATION When the device works well the light of PWR and LINK should be on and DATA should be wink and others should be off Serial Phenomena Causation Solution of the malfunction Light of PWR Check power supply line connection off normal or not Light of LOS E1 signal missing on Check the E1 signal Line connector on the E1 RX terminal clean or not Line break or not opposite device power on or off loopback from the E1 input and output conncetor with the E1 line connecting the light off means the device work well then please check the opposite device and E1 line 13 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO LTD Light of LINK check Ethernet line connection 3 off correct or not the light work maybe the problem Press the PATT and REM buttons correctly but lies in the E1 or make the opposite device loop 4 no data channel back the LAN data if the PTOK light off it means the E1 transmission channel has problem there is data maybe the device Confirm all devices set into the salve but also there clock has problem if yes make one or two of them into 5 is missing of maybe The LAN has the master clock data a great lot COL check the LAN network occur Remark 1 PATT the button set
8. stakes when all indicating lights winks except for the PWR light B both of the device are on the status of line clock both of the device on the status of master clock while the rate setting is different 7 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO LTD the test key connecting are incorrect which cause into the dead cycle 5 3 Button switch There are four button switchers on the front panel they are as following from the left to right ANA E1 Interface local loop to check whether local device and its connecting circuit correct El Interface LAN Interface C3 CONVERT DIG 10 100BASE T Local loop to check the opposite device and optical circuit LAN 1 10 5 El Interface C gt CONVERT Interface REM E1 interface loopback outward to test E1 line 5 E1 LINE C LAN Interface 1901 IH V 54 testing To produce and transmit the PBRS to the 10 100 5 8 5 AD NET Technologies Co Ltd All Rights Reserved V2 0 02 1 AD NET TEHCNOLOGY CO LTD input connector and to check whether the output signal of the 10 100BASE accord with PBRS standard If according the PTOK light on otherwise off By this way the status of E1 Line can be tested PBRS Code El Interfa REC amp CHK ce LINE y KK