1. So the shell shall not be opened otherwise such dangers as electric shock will be caused If any internal overhaul or replacement of the battery is required please contact the distributor The internal short circuiting of the UPS will lead to dangers such as electric shock or fire therefore no water containers such as a water glass shall be placed on the top of the UPS so as to avoid such dangers as electric shock Do not dispose of battery or batteries in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic onthe rating label stands for phase symbol A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hand 2 Use tools with insulated handles Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same type and number of the sealed lead acid batteries The maximum ambient temperature rating is 40 C This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen During the installation of this equipment it should be assured that the sum of
2. shown Incoming Internet Line ku a A gt amp ad p ar 6 Turn On Off Press the switch of the UPS continuously for 1 second and the UPS turns into its normal state the green light is on and the beeper is off after it performs a self diagnosis the beeper and the red and green indicator lights are on for several seconds At this time user may turn on the PC and other loads Press the switch of the UPS continuously for 1 second to turn off the UPS Note 1 For the convenience of maintenance please turn on the UPS first before turning on the PC and the other loads and turn off the UPS after the loads are turned off 2 At ordinary times we recommend to remain the UPS on with the battery charging even if the loads are turned off which is benefit to the maintenance of the battery 3 Trouble Shooting Possible Cause type of battery pressed connection load more 3 Battery defect due to high 3 Replace with the same temperature operation type of battery environment or improper operation to battery fuse properly If any abnormal situations occur that are not listed above please call service people immediately 4 Specification MODEL po MaxPower 1000 CAPACITY INPUT OUTPUT Voltage Regulation Batt 10 Mode 50Hz or 60Hz F Regulation Batt requency Regulation Batt if aus Mode Output Waveform Batt Mode Modified Sinewave BATTERY Battery Type amp Number
3. the leakage currents of the UPS and the connected loads does not exceed 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible In case smoke is found coming out from the device please cut off the power supply quickly and contact the distributor Do not keep or use this product in any of the following environments v Any area with combustible gas corrosive substance or heavy dust Y Any area with extraordinarily high or low temperature above 40 C or below 0 C and humidity of more than 90 Y Any area exposed to direct sunshine or near any heating apparatus v Any area with serious vibrations Outdoor In the event that there is fire occurring in the vicinity please use dry power extinguishers The use of liquid extinguishers may give rise to the danger of electric shock 1 System Description Front panel Power Switch 1 UPS status Indicator AC Mode Green lighting Battery Mode Green flashing 3 Fault LED Red flashing Back Panel 1 Output receptacles 2 Fuse 3 AC Input with AC fuse 4 AC Input 5 Modem Phon
4. 12V 7 2Ah x 2pcs Back up Time at a PC load with 15 monitor Recharge Time 10 hours to 90 after complete discharge Typical 2 6ms 15ms max 30 minutes typical TRANSFER TIME INDICATOR Battery weak Vbat lt 24V at AC Mode AUDIBLE ALARM Fault Continuously sounding Battery weak Vbat lt 24V at AC Mode Battery Fault at AC Mode Sounding three times every 2 seconds Sounding twice every second PROTECTION Full Protection Discharge overcharge and overload protection Red LED flashing every 2 seconds for 30 seconds Sounding every 2 seconds for 30 seconds PHYSICAL Dimension DXWXH mm 280x90 6x237 7 Net Weight kgs 6 5 ENVIRONMENT Operating Environment 0 40 C 20 90 relative humidity non condensing Less than 45dB
5. USER S MANUAL MaxPower 1000 UPS Uninterruptible Power System 28 2MAXPO0019 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for the model MaxPower 1000 that should be followed during installation and maintenance of the UPS and batteries Safety CAUTION This product is specially designed for PCs and it is not recommended for use in any life supporting system and other specific important equipment This equipment can be operated by any individual with no previous training Do not plug household appliances such as hair dryers to UPS receptacles This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity CAUTION Risk of electric shock do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel The utility power outlet shall be near the equipment and easily accessible To isolate UPS from AC input remove the plug from the utility power outlet If UPS is to be stored for a long time it is recommended to recharge the batteries by connecting the utility power to UPS switch ON once a month for 24 hours to avoid a full battery discharge Please do not use the UPS in excess of the rated load capacity The UPS contains one two large capacity batteries
6. e Line Surge Protection Option Installation and operation 1 Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping If any damage is discovered repack the unit and return it to the place of purchase 2 Charging This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 10 hours with no load no electrical devices such as computers monitors etc connected 10 hours 3 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high 4 Computer Connection Plug the UPS into a 2 pole 3 wire grounded receptacle Then connect one computer related device into each of the power receptacles supplied on the back of the UPS 5 Modem Phone Line Connection Plug incoming internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end to the modem input socket as