Home

User's Manual ICS-2100 ICS-2102 ICS-2102S15

image

Contents

1. PLANET ICS 2100 ICS 2102 y ICS 2102515 V ste Industrial RS 232 RS 422 RS 485 AOO o WIR over _ Na io A 100Base FX 10 100Ba T Media Converter un A User s Manual of ICS 210x Trademarks Copyright PLANET Technology Corp 2009 Contents subject to which revision without prior notice PLANET is a registered trademark of PLANET Technology Corp All other trademarks belong to their respective owners Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications and makes no warranty and representation either implied or expressed with respect to the quality performance merchantability or fitness for a particular purpose PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading
2. The ICS 210x can be set to TCP Server mode and connect the PLC The administrator can configure and set command settings through Fast Ethernet intranet to control the PLC the administrator and workstation There is no need to be always sets by the side of the I O machine Factroy Managed amp Control Center ICS 2100 RS 232 485 Converter internet TCP Server ICS 2100 RS 232 485 Converter TCP Server Figure 1 2 Industrial Serial Converter for Factory PLC Application RTU Data Collect UDP Mode Connect with RTU Remote Terminal Unit to collect and monitor the data of waves signal and power utilization 1ICS 210x can be used to set up UDP mode and send data over Fast Ethernet to Local server or over internet to remote server automatically Local Data Collect Server ICS 2100 Unit a sn RTU tg Remote Terminal r A Mise TA WF I Cce iS i IL Figure 1 3 Industrial Serial Converter for Factory RTU Application Surveillance Motion Control Pair Connection Mode User s Manual of ICS 210x Using pair connection along with fiber optical patch cord the ICS 210x extend RS 232 RS 485 interfaces distance from surveillance and scanner to the control keyboard joystick which is installed in the remote monitor center Lab Public Area _ Internet 15km CAR BS ICA 601 ICS 2102515 Client ICS 2102515 Master Figure 1 4 Industrial Serial Converter for
3. Distance Extend Application 1 5 Product Features One RS 232 and the other RS 422 485 port to one 10 100Base TX or 100Base FX Media Converter Cost effective solution for RS 232 RS 422 RS 485 to Ethernet application Supports RS 232 with DB9 interface 4 wire RS 422 or 2 wire RS 485 with terminal block operation Asynchronous serial data rates up to 230400bps Ethernet Interface Complies with IEEE 802 3 IEEE 802 3u 10 100Base TX 100Base FX standard Supports auto MDI MDI X function on RJ 45 Port for ICS 2100 Supports 100Base FX multi mode SC concocter up to 2km for ICS 2102 Supports 100Base FX single mode SC concocter up to 15km for ICS 2102815 Smart Functions Standard TCP IP interface and versatile operation modes Software Protocol Support ARP ICMP TCP IP UDP HTTP server DHCP client Telnet server client Built in IP Base Web interface for remote management Serial Operation mode selected via Web management Pair Connection mode for connecting two serial devices over a network PLANET Smart Discovery utility automatically finds client devices on the network Firmware upgrade via HTTP protocol Hardware LED indicators for easy network diagnose Reset Button at the front panel for reset to factory default 4 User s Manual of ICS 210x Industrial Case Installation n IP 30 Metal case Protection a DIN Rail and Wall Mount Design En 12 to 48V DC redundant power with polarity reverse protect function and connective remov
4. or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at whose own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately Revision PLANET Industrial RS 232 RS 422 RS 485 over 10 100Base TX 100Base FX Media Converter User s Manual FOR MODELS ICS 2100 ICS 2102 ICS 2102S15 REVISIO
5. provided Therefore this product will perfectly satisfy the diverse demands while providing reliable and efficient network solutions based on the distance and budgets of installation User s Manual of ICS 210x The ICS 210x make connected Serial equipment becomes IP based That also makes them be able to connect to a TCP IP networking immediately Each Web Smart converter is able to manage through the Web Interface The powerful Web Smart Media Converter supports Application mode Serial operation mode connect alarm and IP address etc Management function helps reduce the amount of valuable time that a network administrator spends detecting and locating network problems otherwise it requires visual inspection of cabling and equipment Multiple connection options for large networking environment are available as well The ICS 210x provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found on plant floors or in curb side traffic control cabinets The feature of operating temperature range of 10 to 60 Degree C coupled with hazardous location certification Class 1 Division 2 allows the ICS 210x to be placed in almost any location The ICS 210x equip with compact IP 30 standard metal case that allows either DIN rail or wall mounting for efficient use of cabinet space the ICS 210x provides an integrated power supply source with wide range of voltages 12 to 48V DC for worldwide oper
6. ATION vi AAA 24 4A OPERATION MODE sirier A A 25 E A O A 25 442 TOP liceali 31 User s Manual of ICS 210x 44 3 UDP Olient Mode iii E 32 444 VifualCOM Mode nai 33 AAS Te lMetoern er MOGE liacle lei 39 4 4 6 Pair Connection Local Mode accion a ta 44 4 42 Pail Connection Remote Modulada dad 45 4 5 SERIAL PORT CONFIGURATION ssa lalla 49 AO SM O n 51 5 SOFTWARE VC ON UTIL sra sms 54 91 INSTALLING THE MC O MU soos hd Sen farce li illa nl NR 54 52 SEARCH THE DEVICE cca 57 DE IR As ille 58 APPENDIX A iii aliados 61 AS PLANE E SWART DISCOVERY UTILITY alia aca Malalt 61 A 2 DEVICE S RJ 232 RS 422 RS 485 PIN ASSIGNMENTS ii 62 ASS DEVICE S RIAS PIN ASSIGNMENTS aria aa A 63 AA RISAS GABLE PIN ASSIONMEN Toni 63 A 5 FIBER OPTICAL CABLE CONNECTION PARAMETER ii 64 4 User s Manual of ICS 210x 1 INTRODUCTION Thank you for purchasing PLANET Industrial RS 232 RS 422 RS 485 over 10 100Base TX 100Base FX Media Converter ICS 210x series Terms of Industrial Serial Converter means the products mentioned titled in the cover page of this User s manual 1 1 Package Contents Open the box of the Industrial Serial Converter and carefully unpack it The box should contain the following items Check the contents of your package for following parts Industrial Serial Converter x1 CD ROM User s Manual x1 Quick Installation Guide x1 Wall Mount Kit x 1 If any of th
7. CC Class A CE Certification Class IEEE 802 3 10Base T Standards IEEE 802 3u 100Base TX 100Base FX EIA TIA RS 232 422 485 IEC60068 2 32 Free fall Stability Testing IEC60068 2 27 Shock IEC60068 2 6 Vibration Not Reset Button at the front panel for reset to factory default 6 User s Manual of ICS 210x 2 HARDWARE INSTALLATION This section describes the hardware features and installation of the ICS 210x s components on the desktop or shelf For easier management and control of the ICS 210x familiarize yourself with its display indicators and ports Front panel illustrations in this chapter display the unit LED indicators Before connecting any network device to the Industrial Serial Converter please read this chapter completely 2 1 Hardware Description 2 1 1 Product Layout Figure 2 1 to Figure 2 2 show front panel of ICS 210x ICS 2100 ICS 2102 ICS 2102515 RS 232 RS 422 RS 485 over 10 100Base TX RS 232 RS 422 RS 485 over 10 100Base FX FE PAULI DNW 8 Bi mm a pa LIE p pH LNE 1 ACT LAN Serial ACT LAN Serial Bande Mode 14100 ig FH ICS 2100 Figure 2 1 PLANET ICS 2100 Front Panel Figure 2 2 PLANET ICS 2102 2102S15 Front Panel 7 User s Manual of ICS 210x 2 1 2 LED Indicators Color Function P1 Green Lit Indicate the power 1 has power Green Lit Indicate the power 2 has power FAULT Green Lit Indicate the either power 1 or power 2 has no pow
8. N 1 0 APRIL 2009 Part No 2080 AA3600 003 User s Manual of ICS 210x TABLE OF CONTENTS INTRODUCTION silla 1 ALT PACKAGE CONTENTS tit tl 1 12 MON TO USE TES MANUAL alessia alibi 1 ISPRODDETDESCRIPTION aaa 1 VAART ON Spalla 2 to PRODUCT FEATURES vse iatale e eel do ad e roi a aes 4 126 PRODUCT SPECIFICATION cessitat ll ela 5 2 HARDWARE INSTALLA TIO Novus iaa 7 ZA MARDWAREDESCRIPTION al iaia T O cal as a TO AA a n Ber er titani Dent dat Set T AN A MIMO AON Saa a ra iaia 8 2 1 3 DB9 and Terminal Block Pin Define ii 8 2 1 4 Industrial Serial Converter Upper Panel ei 9 ZNO WINING he Porpora 9 2 1 6 Wiring the Fault Alarm Contact ei 10 2 2 MOUNTING INSTALLATION As 11 2 2 1 DIN Ral MOUNU o A LALA LILLE A EE 11 2 2 2 REMOVE DIN Rall VOUNITAG sidecar 12 2 2 3 Wal Mount Plate Mounmg ca aper Alceo 12 224A Stand alone Installationi s ie ls A E aaO E 13 3 INDUSTRIAL MEDIA CONVERTER MANAGEMENT 15 3 VOVER VIE adiacenti 15 SZ REQUIREMENTS hci cai e 15 S 3MANAGEMENTMETHOPS Liliaceae 16 E lara 16 s gt SZ Logintne Media COnveleks iridati 16 4 WEB MANAGEMENT usas 18 A NIMAIN MEN a E A desire A chu ott see A Dann Sosa etme Seance aie 18 4259 ira 19 4 2 SY Ste mt IO NAO ssaa laicale iatale 19 42 2 RaSSWOrd A A ee 20 AL UE FR CLAY AIM A A AAA A ad 20 ALAFWA UG ACS nt AOS 21 42 o Factory Deal isa 23 A 2 0 System Reboot at ec a EE pere E 23 4 3 NETWORK CONFIGUR
9. ability with high availability applications requiring dual or backup power inputs 1 4 Applications Access Control System Traditional Installation Most of the enterprise and government use access control plate and Mifare or RFID to authorize the entrance identity With traditional deploy access control machine use RS 232 or RS 485 serial interface and cables connect to login server With connection to ICS 210x Serial over Fast Ethernet Converter the access control machine is able to be extend over longer distances via fiber optical interface The distance can be up to 15km in a local range Or the ICS 210x can be linked to a xDSL router to get the internet access capability the access control can be set and monitored over the internet ae 7 ACCESS 100Base Fx i PTS Control ne KIM Adminstration Department 3 Account Authentication Server mi i po h p pl F E Control ACCESS Control ar KT b b bb ba s bb ba bb b b b E O Vera INF I I Vidas FX Arop ET Figure 1 1 Industrial Serial Converter for Access Control System Application De User s Manual of ICS 210x Process Control To monitor configure and manage the Robot conveyer including other machines in a manufacturing PLC Programmable Logical Control is required The PLC is used to drive above the manufacturing machines process
10. able terminal block for master and slave power a Supports EFT protection 6000 VDC for power line Supports 6000 VDC Ethernet ESD protection a 10 to 60 Degree C operation temperature 1 6 Product Specification Model ICS 2100 ICS 2102 ICS 2102S15 Serial Port RS 232 x 1 Interface RS 422 RS 485 x 1 DB9 for RS 232 Connector A oO block for RS 422 RS 485 Baud Rate Baud Rate Data Rate Rate 300bps to 230400bps to 230400bps Data Bits 5 6 7 8 Parity Type 1 1 5 2 Stop Bit Odd Even None Space Mark Flow Control H W None RS 232 DCD RxD TxD GND RI RS 422 Tx Tx Rx Rx RS 485 Data A Data B Fast Ethernet Port Standard 10 100Base TX 100Base FX Mos bo Mime singiemode Distance oom am pime Optical Wavelength 130mm fom 50 125um or 62 5 125um l 9 125um single mode cable multi mode fiber cable Hardware System Power 1 Power 2 Fault LED Indicators TP or Fiber Port Link Active Serial Port Serial port mode RS 232 RS 422 or RS 485 Web Management Management PLANET Smart Discovery Utility Operation Mode UDP Client 5 User s Manual of ICS 210x Virtual COM Telnet Server Pair Connection Remote Slave Pair Connection Local Master Weight Mess i e Mechanical Mei o Operating Temperature 10 60 Degree C Storage Temperature 20 75 Degree C Operating Humidity 10 90 RH Environment Storage Humidity 5 90 RH Emissions F
11. er Laia To indicate that the Fast Ethernet Port is successfully connecting to the ights TP or Fiber gt progr at 10Mbps or 100Mbps Blinks To indicate the Fast Ethernet Port is receiving or sending data Lights To indicate that the UART Port is connected successfully Blinks To indicate the UART Port is receiving or sending data 2 1 3 DB9 and Terminal Block Pin Define DB9 Pin Define for RS 232 DB9 PIN RS 232 1 Do 2 RD 8 De CS Ls ep e Ei i 8
12. ese are missing or damaged please contact your dealer immediately if possible retain the carton including the original packing material and use them against to repack the product in case there is a need to return it to us for repair 1 2 How to Use This Manual This Media Converter User Manual is structured as follows Section 2 Installation It explains the functions of ICS 210x and how to physically install the ICS 210x Section 3 Management The chapter explains how to manage the converter by Web interface Section 4 Web Configuration It contains information about the Smart function of ICS 210x Section 5 Software VCOM Utility It explains the software VCOM how to use with the operation Virtual COM Appendix A It contains cable and Smart Discovery utility information of ICS 210x 1 3 Product Description The Web Smart ICS 210x series Media Converter Device Server provide to converts Industrial Serial RS 232 RS 422 RS 485 communication interface over Fast Ethernet networking There are RJ 45 SC connectors and single mode multi mode media for your needs Ethernet signal that allows two types of segments to connect easily efficiently and inexpensively It s time saving expense for user and SI no need to replace the existing Serial equipment and software system It extends the distance of deploying Serial equipments and hosts The selectable fiber Optic wires on the basis of distance are flexibly