1. gt TRUE SOURCE User Manual Alternating Air Mattress amp Pump System Model TS 105 A ATT C FE IPXO No AP APG UM 105 E V7 0 Copyright 2010 by TRUE SOURCE Technology Co Lid 10 11 12 13 14 Table of Contents Safety Criteria Warnings Product Functions Product Setup Contents Product Features Installation Initial Inflate Method Emergency CPR Deflate Power Unit Settings Contents Routine Maintenance and Cleaning Storage Troubleshooting Technical Specifications Warranty 10 I 1 Safety Criteria CE EN60601 EN60601 1 EN 60601 1 2 FCC Part 18 Class B Type BF Applied part Attention consult Accompanying documents Operating instructions C Fe No AP APG IPXO Medical Device Classification Class 2 Warnings The product is only intended to be used as an auxiliary device The manufacturer does not have the absolute responsibility and obligation to guarantee its full effects Power Unit Do not open the power unit without guidance to prevent danger Do not insert items into any opening of the power unit Do not drop the power unit Do not use the power unit in places exposed to water liquids oil smoke and flammable chemicals Use fuses as marked T1A 250V The product is contraindicated to anesthesia procedures and is only indicated for use by the user in normal conditions This the power unit is not AP APG protected Air Matt
2. Follow the national requirement to dispose the power unit 1 Pull down the CPR lid for instant quick deflation 2 Clean the mattress Caregivers must wear gloves and masks and protected with disinfection 3 Roll up the mattress and the connectors 4 Place in a dry place 12 Troubleshooting Inspection Procedure Possible Solution 1 Power unit 1 1 Check if the two ends of the 1 1 Confirm if the wall socket has does not power cable are safely connected to power supply operate the power unit and the socket 1 2 Check if the power switch on 1 2 If not switch to ON the side of the power unit is switched to ON 1 3 Check if the fuse has burnt out 1 3 Turn off the power and check or not properly installed the fuse 2 Power unit Is working but mattress is not inflating 2 1 Check if air comes out of the power unit and if the connector is properly connected 2 1 If the unit operates normally but no air comes out it is possible that the power unit has something wrong inside and needs repair 2 2 Check if the CPR lid falls off 2 2 Repair or replacement is needed if the lid is damaged 2 3 Check if the mattress 2 3 Repair or replacement is connector is bent or falls off needed if the connector is deformed and cannot be restored or the material is not in its normal state 2 4 Check if the air hose is 2 4 Repair or replacement is damaged needed if the air hose is damag
3. al resources Using the mattress replacement system can aid the prevention of pressure ulcers and effective treatment of patients The air mattress can be placed on the overlay of a standard medical bed The support surface can be alternately inflated and deflated with two or three rows of coupled air hoses that are connected to the power unit and activated in the Alternating Pressure Mode Theory of Alternating Pressure Mode This process allows effective arrangement in a way that a single area of the body remains in a completely pressure free and lifted state for a fixed period This allows body tissues to be temporarily relieved of pressure and blood to circulate smoothly around the tissues This in turn heals improves and prevents the occurrence of pressure ulcers 4 Product Setup Contents 1 One the power unit 2 One the air mattress Include coverlet 3 One power cord 4 One users manual 5 Product Features Enhanced Design Features of the Power Unit 1 For hanging the safest iron material is used for hanging hooks and its withstanding ability is far higher than plastic material 2 For shock absorption the deflation pump inside is equipped with a specially designed suspension shock absorption system and a foot mat is provided outside the unit in order to reduce the shock when the unit is in contact with the patient s bed 3 The compact size feature The system is of a compact size making it easy for placement and s
4. ed 2 5 Check if the air cotton filter is 2 5 Replace the filter if it is heavily soiled and the air is blocked heavily soiled 3 Bottom in Check weight setting Increase weight setting contact with the overlay 3 2 Check if air leaks from the 3 2 Replace the air cells if mattress damaged 3 3 Check if the air cotton filter is 3 3 Replace the filter if it is heavily soiled and the air is blocked heavily soiled 4 Others Problems other than the above Contact the local distributor for handling 13 Technical Specifications The Power Unit Specification Input AC220 240V 50 60Hz OR AC100 120V 50 60Hz Power Consumption 10W max Fuse Rating T1AL 250V Weight 1 3Kg approx Dimension L26cm W8cm H13cm Air flow rate 3 8 liter min Alternating cycle time 5 6 min pre Class Type BF The Air Mattress Specification Allow different setup for marketing Standard State D Air cells 21pcs totally Material Coverlet PU membrane Elastic Fabric Air Cells Nylon PU Base Nylon PVC lt gt Dimension L195cm W85cm H13cm O Weight 3 8Kg approx Temperature amp Humidity Limited Operating Temperature 5C to 45 C 41 F to 113 F A Transportation Temperature 10 C to 45 C 14 F to 113 F A Transportation Humidity 5 to 95 Storage Environment Storage Temperature 5 C 45 C Storage Humidity 10 to 80 10 14 Warranty The warranty peri
5. n air cells are completely deflated it is recommended to inflate the mattress by connecting an external pump with the hose for quick inflation When the air cells are inflated over 2 3 reconnect the hose to the power unit before the user is allowed to lie on the mattress The inflation tool maybe can be purchased from the dealer Emergency CPR Deflate A Emergency CPR Deflate Pull open the CPR lid When the patient lies down pull down hard on the plastic piece marked with CPR that drops from the chest position on the right side Then pull down the CPR lid for instant quick deflation B Remember to resume the CPR lid for the Resume Function otherwise it may lead to the danger of incomplete inflation C Pull open the CPR lid to deflate non alternating air cells for storage Patent design No M347104 amp ZL 200820136935 2 9 Power Unit Settings Contents Adjustment of the comfort range The adjustment range is based on the user s the bottom that can t contact with the overlay The softness and hardness of the air mattress can be selected from the number 1 to 10 to provide users comfortable Suggestion Normal setting in number 5 Users weight limit 30kg to 120kg 10 Routine Maintenance and Cleaning The Power Unit 1 Avoid using the unit when the air is poor Do not smoke especially to prevent nicotine and greasy tar like substance from entering the unit and resulting in the deterioration of i
6. nternal pipes and the need for frequent replacement of the air cotion filter 2 Thoroughly wipe down the dust or smear stuck on the exterior of the unit with a dry cloth and neutral detergent it is recommended to clean the pump once a week Caregivers must wear gloves and masks and protected with disinfection 3 An air purifier can also be used to maintain the air quality 4 Replacement of the air cotton filter it is recommended to replace the filter once a month Please purchase the filters from the dealer The Air Mattress 1 Thoroughly wipe down the coverlet air cells and base with a dry cloth and neutral detergent or the 70 medical alcohol Caregivers must wear gloves and masks and protected with disinfection 2 Keep the coverlet even to prevent the formation of horizontal shear resulted from crinkles and the tightened skin 3 Do not wash the air cell please wipe down it only Improper handle for cleaning and hygienic control for the system will cause cross infection Storage 1 It is necessary to turn off the power switch in side panel unplug the power cord 2 Disconnect the power unit and the power cord disconnect the power unit and the hose at the feet end of the mattress 3 Put the power unit and the power cord in the box and place in a dry place 4 When the power unit is put away and not in constant use it is necessary to switch it on for 3 hours at regular intervals to lengthen its life 5
7. od for the power unit is 12 months and the air mattress is 12 months as of the purchase date of the product provided that the product is used in normal conditions Repair outside the warranty period is subject to charge The maintenance service for the product is warranted for 5 years Upon the completion of maintenance outside the warranty period an additional 6 month warranty period is provided During this period the same general terms and conditions of warranty apply Only function failure repair is covered during the warranty period The warranty does not include general maintenance e g replacement of the cotton filter cleaning setting adjustment or component renewal The warranty does not cover maintenance conducted by opening the power unit without authorization careless dropping or use of the product other than for its intended purpose and repair of such is subject to charge Manufactured for TRUE SOURCE Technology Co Ltd 4F 523 Chung Chueng Road Hsin Tien City Taipei Hsien Taiwan Tel 886 2 8667 1780 Fax 886 2 8667 1782 http www truesource com tw air index_new asp 11
8. ress Do not shift to CPR mode during normal use Prevent the patient from placing his her head or neck between the mattress and the side rail Do not use sharp or pointed objects since this will damage the mattress or use high temperature objects since this may accidentally destroy the mattress Do not use the mattress in places exposed to water liquids oil smoke and flammable chemicals The product is contraindicated to anesthesia procedures and is only indicated for use by users in normal conditions This the air mattress is not AP APG protected 3 Product Functions Purpose The product is for the purpose of aiding the prevention of pressure ulcers and effective treatment of patients Pressure ulcers are commonly known as bedsores They occur when there is damage caused by pressure or shear or friction to the skin or even the underlying tissues muscles and bones Pressure ulcers are a common problem of patients suffering from long term physical immobility including those who are inflicted with spinal cord injury bedridden for a long term not clearly conscious inflicted with bladder or bowel incontinence diabetes skin fragility physical weakness or malnutrition It is an extremely complex task to treat pressure ulcers once they occur In a minor case the wounds take weeks to heal In a severe case sepsis amputation or death may occur This not only damages health but also is a burden to and waste of medic
9. ted areas because the fabric has the advantage of a proprietary medical fabric that is not easily crinkled It is not widely used mostly due to consideration of costs We use the fabric because functionality is taken into prior account 6 Installation Step 1 step 2 Step 3 Step 4 step 5 Step 6 step 7 Step 8 Step 9 Place the air mattress evenly on the overlay The end with a connector to the power unit is the feet end Check if the securing position of the air cells is centered Secure the overlay of the bed with the elastic bands on the four sides at the back of the base Hang the power unit on the panel at the feet end Connect the hose at the feet end of the mattress to the air outlet of the unit Connector the power cord to the AC Inlet of the power unit Plug the power cord of the power unit to a socket with power supply Turn ON the power switch on the side of the power unit and the green indicator turns on Air starts to enter the hose in a few seconds Comfort Range Knob select 1 to 10 See Power Unit Settings Contents Please wait until all the air cells are inflated by at least 2 3 of their volume approx 10mmHg or for 30 minutes before the user is allowed to lie on the mattress T Initial Inflate Method 1 Wait until the power unit slowly inflates the mattress However initial inflation takes at least 30 minutes before the user is allowed to lie on the mattress 2 Whe
10. torage and taking into account the streamlined system appearance and practicality 4 Ihe cotton air filter is to be replaced outside Therefore the replacement can be done without opening the unit 5 The use of the double external fuse holders allows the unit to provide better safety protection 6 The specialized power management with an independent power cord and a master power switch on the side can better ensure safety Design Features of the 5 air mattress standard state 5 Air cells 21pcs totally It narrow distance for air cell to next to increase the user s comfort and security Patent Design of CPR Quick Valve When it is necessary to perform CPR the chest part needs to be deflated extremely quickly Simply follow the standard simple operation by pulling down Head End 3 Hoses No Alternating Design Front 3 Hoses No Alternating Design ensures no alternation at the head end to increase the user s comfort and security Base Design The four sided standing base uses securing cells The positions of suitably provided binding cells make it easier to secure the mattress in the bed The wide elastic bands on the foam mattress are used to secure the existing overlay Coverlet Design The light moisture permeable elastic fabric with a costly PU lamination is the main surface in contact with the patient The purpose is to prevent shear and friction from damaging the patient s skin and inflic
Download Pdf Manuals
Related Search
Related Contents
Simpson Strong-Tie SP6 Installation Guide 台数限定 特別価格!! - ハーモネートショッピングクラブ EDITAL PREGÃO PRESENCIAL Nº 30/2012 User manual Rev. 1.2 (17/04/2015) 化学物質等安全データシート SPEX-PM_User Manual GUIDER+ GPSガイダー VRS-RTK簡易取扱説明書 NOX-ESNAP10PAC2-Technical Drawing.cdr Instruction Manual Spanish Copyright © All rights reserved.