Home
3777 - F - Radiant Heat Pump Owners Manual - LR
Contents
1. a small particle of foreign matter and rectify the fault Steady Flow PTR This may be caused by excessive water supply pressure a faulty PTR Valve or a faulty thermostat Turn off the electricity supply turn off the water and contact your Radiant agent No Hot Water e ls the Pressure amp Temperature Relief Valve discharging too much water e Do you have the correct size water heater for your requirements Sizing details are available from your Radiant supplier e Is one outlet such as the shower using more hot water than you think e Carefully review the family s hot water usage and if necessary check the shower flow rates with a bucket measuring the amount of water used over that period of time If it is not possible to adjust water usage patterns an inexpensive flow control valve can easily be fitted to the shower outlet e Consider that during night time heating the time taken to heat the tank can take longer because there is less energy in the air so you may find that the tank has not fully recovered from a period of heavy usage during the previous evening e Consider that often the hot water usage of showers washing machines and dishwashers can be under estimated Review these appliances to determine if your daily usage is greater than the storage volume of your water heater If for example you have a 315 litre storage tank and you are using 450 litres of water it is possible that there wil
2. allow water to escape through the hose To flush the heater carry out steps i to iv above Disconnect the hot water inlet union and attach a water supply hose to the heater Turn on the water supply vi Flush the heater until clear water appears then reconnect all fittings fill the heater and restore the electricity supply vii Draining the Water Heater To drain the water heater follow steps i to v above until no more water escapes from the appliance H3777 3777 Rev F 21 Owners Manual Radiant Heat Pump RADIANT HOT WATER Warranty Radiant Hot Water Unit Manufactured by Dux Manufactur ing Limited Dux Terms of Warranty and Replace ment Guarantee All Radiant water heaters manufactured and sold after 1 January 2011 are backed by a comprehensive one 1 year full parts and labour warranty conditions apply see below Furthermore the Radiant tank includes a guarantee to replace your hot water unit if the inner cylinder fails within five 5 years conditions apply see below The terms of the Warranty and replacement guarantee are set out below 1 Year Comprehensive Warranty Your Radiant hot water system and its components are covered by a one 1 year parts and labour warranty against defective factory materials or workmanship from the date your hot water unit is installed or two 2 years from date of manufacture whichever occurs first 2 Year Refr
3. as causing potential damage to other components Filling the system with water Once the system plumbing is completed for the household and the Radiant Heat Pump has also been connected the tank can be filled with water and pressurised Caution The water heater must be filled with water before turning on the electricity supply Caution If the water heater is left in an operating condition and unused for two weeks or more a quantity of hydrogen which is highly flammable may accumulate in the top of the water cylinder To dissipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not a dishwasher clothes washer or other appliance During this procedure there must be no smoking no open flame or any other electrical appliance operating nearby If hydrogen is discharged through the tap it will probably make an unusual sound similar to that of air escaping H3777 3777 Rev F RADIANT Owner s Manual Radiant Heat Pump HOT WATER Electrical Connection Electrical Connection The unit is designed for connection to CONTINUOUS TARIFF single phase 240 volt AC supply Tariff 33 QLD only single phase 240 volt AC supply The electrical connection must comply with local supply authority regulations and AS3000 For the Electrician the access cover may be removed by undoing the two screws on the cover and sliding the cover downward to disengag
4. RADIANT HOT WATER Owner s Manual RADIANT Heat Pump Water Heater Model R2FHG1000C Installation Details Owner s Information Warranty For advice repairs and service call 1300 365 115 Australia 0800 729 389 New Zealand Carefully remove all packaging and ay transit protection from the heater before te installation Dispose of the packaging responsibly using re cycling facilities where they exist Specifications and materials may change without notice Effective for Radiant Heat Pump water heaters manufactured and sold after 1st Jan 2009 H3777 3777 Rev F RADIANT Owner s Manual Radiant Heat Pump HOT WATER Contents Welcome To Radiant Hot Water Installation Details Plumbing Connections Electrical Connection Installation Checklist Commissioning The System Operational Diagrams Commissioning Checklist Owner s Instructions Troubleshooting System Maintenance Safety Information Service Information Warranty Warranty Card Radiant is a registered trademark of Dux Manufacturing Limited Dux Manufacturing Limited 2011 All rights reserved 20 21 22 25 H3777 3777 Rev F Owners Manual Radiant Heat Pump RADIANT HOT WATER Welcome To Radiant Hot Water Your decision to purchase a Radiant Hot Water system will reward you for many years to come Since 1915 the Dux range has seen continuous research and development resulting in many breakthroughs in the ef
5. ana ana H3777 3777 Rev F 25 RADIANT Owners Manual Radiant Heat Pump HOT WATER RADIANT Heat Pump Water Heater RADIANT For advice repairs and service call 1300 365 115 Australia 0800 729 389 New Zealand GWA Smarter Solutions H3777 3777 Rev F G
6. arranty claims can be made at the point of sale or by posting or faxing a warranty claim to Dux contact details listed below within one 1 month of the appearance of a defect Warranty claims under this extended warranty must include the following details e Date of Purchase e Location of Purchase e Proof of Purchase e Contact Details e Product Serial Number Contact details Dux contact details are as follows Postal Address Dux Manufacturing Limited PO Box 209 Moss Vale NSW 2577 Australia Telephone 1300 365 115 Australia 0800 729 389 New Zealand Facsimile 61 2 4868 0257 Web http dux com au Note If the Unit is located in a position that does not comply with the installation instructions or relevant statutory requirements then this extended warranty does not cover major dismantling or removal of cupboards doors walls or special equipment and or excessive labour at the determination of Dux to make the Unit accessible for repair or replacement As required by legislation including under the ACL any claims for damage to furniture carpets walls foundations or any other consequential loss either directly or indirectly due to defects of any kind in a Unit will only be met by Dux where the damage could be considered reasonably foreseeable Our goods come with guarantees that cannot be excluded under the ACL You are entitled to a replacement or refund for a major failure and fo
7. ation Details Preferred Location If possible the location selected for the heat pump should be on the warm side of the home The selected location must have free ambient air flow to prevent cooler discharged air being drawn back into the heat pump Allow sufficient clear space so as not to impede this air flow Allow 700 mm clearance above the Radiant Heat Pump and allow 150mm clearance to either side of the Radiant Heat Pump as a general rule 700mm 150mm 150mm i lt lt gt gt _ H3777 3777 Rev F RADIANT Owner s Manual Radiant Heat Pump HOT WATER Noise Considerations The selected location must consider noise impact on living areas especially bedrooms inside the house Although the running noise level is very low 51 dB A it can be expected that the heat pump will run during the night The installer can assist in choosing the appropriate location for the Radiant Heat Pump Air Flow Ensure the unit is placed in an area were debris such as leaves and paper etc will not collect and block the air outlet on the top of the unit Important Do not put any objects on top of the Radiant Heat Pump unit Installation Details Transportation Ensure the Radiant Heat Pump is always stored and transported in an upright position Note All warranty is voided if the unit is laid on its side for storage or transport It must be stored and transport
8. e it from the case Note This water heater is fitted with a thermostat and over pressure cut out switch Under no circumstances should the water heater be operated without both these devices being in the circuit Replacement must be carried out only by a qualified electrician or the manufacturer Danger The operation of the thermal cut out indicates a possibly dangerous situation Do NOT reset the thermal cutout until the water heater has been serviced by a qualified person Caution Water heater must be filled with water before turning on the electricity supply Electrician Press the reset button on thermostat to ensure over temperature cut out is set H3777 3777 Rev F RADIANT Owners Manual Radiant Heat Pump HOT WATER Electrical Connection Hotlogic Operational Codes Red light Status Green light Power LED Status LED VEN ELON Green Red Alternating Power on initialisation LEDs blink alternately On off Power on On On Fan on compressor on off Flashing off Ambient sensor error possible tank sensor error off Flashing Tank sensor error Flashing Flashing Over Pressure Switch tripped H3777 3777 Rev F 9 HOT WATER RADIANT Owner s Manual Radiant Heat Pump Always transport the Radiant Heat Pump in the upright position if you lay it on its side the refrigeration system may be compromised and the system may fail Avoid installing the unit near a bedroom window The Rad
9. ed in a near vertical position at all times with no exceptions No more than 45 from vertical H3777 3777 Rev F RADIANT Owner s Manual Radiant Heat Pump HOT WATER Plumbing Connections Installation Dimensions Table mm 250 Litre Tank Diameter 635 sn l Height from base of heater Hot Water Outlets B 1231 Cold Water Inlets 215 A Minimum top clearances Sides 150 Top 700 All measurements approximate only Specifications and material are subject to change without notice Cold Water Connection An approved isolating valve non return valve line strainer optional but recommended and union must be fitted between the supply main and the RP34 20 socket in the water heater All fittings must be approved by the relevant installation Authority Storage Tank Installation Install and connect the storage tank to the household water reticulation system as per local plumbing regulations and codes Install a condensation drain line in a continuous fall away from the heat pump to a safe and legal point of discharge Usually this would be a garden bed or similar location H3777 3777 Rev F Owners Manual Radiant Heat Pump RADIANT HOT WATER Plumbing Connections Note for S A and W A It is a state requirement that a pressure relief valve be fitted on the cold water supply line between the non return valve and the water heater Hot Water Connection The
10. ficiency reliability and longevity of hot water systems Radiant water heaters are manufactured in Australia in a state of the art facility using a Quality Endorsed Company production system This is your assurance that you have purchased the highest quality water heater available one that will provide continuous hot water for all your needs safely economically and for many years to come To be upfront about it we want Radiant to be your brand of choice So you can depend on us to provide more than just a hot water system You can rely on Radiant products and choose them with confidence We ll make sure you have the information the quality and the innovation you re looking for including the latest energy saving alternatives If you should ever have a problem and we ll bet you won t you ll find that we re easy to get hold of friendly to talk to and quick to act Our service is all about providing anything you need as soon as you need it Go with Radiant and you ll have a dependable economical efficient hot water system designed to perform well year after year And that s a promise H3777 3777 Rev F Owners Manual Radiant Heat Pump RADIANT HOT WATER This water heater must be installed by a licensed tradesperson and in accordance with e AS NZS3500 4 2 National Plumbing and Drainage Code Hot Water Supply Systems Acceptable Solutions e AS NZS38000 e Local autho
11. h as pressure limiting valve tempering valve line strainer stop cocks non return valve electrical switches pumps or fuses or faulty installation The Unit must be installed by a licensed plumber in accordance with information set out in the Owner s Manual and or Installer s Guide supplied with the Unit and or any relevant statutory requirements In addition to this extended warranty certain legislation including the ACL may give you rights which cannot be excluded restricted or modified This extended warranty must be read subject to such legislation and nothing in this warranty has the effect of excluding restricting or modifying those rights If Dux fails to meet a guarantee implied by the ACL your remedy for such failure may be limited to any one or more of the following e replacement of the Unit e repair of the Unit e refunding the cost of the Unit e payment of reasonable costs of having the Unit repaired e payment in respect of the reduced value of the Unit Any defective part of the Unit must be returned to the point of sale before replacement can be considered under the terms of this warranty If the costs H3777 3777 Rev F 23 RADIANT Owner s Manual Radiant Heat Pump HOT WATER Warranty of returning any defective parts are unreasonable please contact Dux on 1300 365 115 Australia or 0800 729 389 New Zealand so that we can arrange a collection if appropriate W
12. hot water line should be connected to the RP84 20 socket as shown on the Installation diagram For the most economical operation of the water heater it is recommended that all hot water lines are insulated with high temperature UV resistant 18mm closed cell insulation Please check local regulations regarding the use of hot water supply pipe work that are not made of copper Pressure amp Temperature Relief Valve The Pressure amp Temperature Relief Valve is Supplied loose with the water heater The valve rating is 250L Model 1000kPa The relief valve must be installed directly into the top socket marked RELIEF VALVE The drain line from this valve must run in a continuously downward direction with the discharge end left permanently open to atmosphere The Pressure amp Temperature Relief Valve supplied with the water heater is not intended to enable connection of the water heater to supplementary energy sources such as solar panels or slow combustion stoves refer AS NZS 3500 4 2 for guidance on these types of installations Warning A separate drain line must be run for this relief valve It is not permitted to couple drain lines from relief valves into a single common drain line Water Quality Your Radiant water heater has been manufactured to suit all water conditions in All Water Areas present in Australia Please note that harsh water supplies can have a detrimental effect on a water heater and i
13. iant Heat Pump produces water condensation So make sure the unit is installed on a flat surface and that a drain line is installed from the condensation drain port so as to conduct the water to a suitable drainage point Tempering Valves are a requirement ensure they are commissioned correctly Incorrect commissioning can lead to a lack of hot water delivery The use of a Reliance brand tempering valve is recommended It is recommended that all hot water lines are insulated with high temperature UV resistant 18mm closed cell insulation 6 Installation Checklist Ensure there is no obstruction on top of the Radiant Heat Pump that will block the air outlet When the system is turned on check the Hotlogic s status lights inside the top cover to help you determine operational status If it is not displaying the green power LED refer to the table of Hotlogic Operational Codes on page 9 to determine the best course of action The Radiant Heat Pump is designed for connection to CONTINUOUS TARIFF single phase 240 volt AC supply Tariff 33 QLD only single phase 240 volt AC supply H3777 3777 Rev F Owners Manual Radiant Heat Pump RADIANT HOT WATER Commissioning The System When both the plumbing and electrical connections have been completed the system is ready to run Before applying power to the system ensure that the system is full of water and pressurised Turn on the powe
14. igerant Components Replacement Guarantee If a refrigerant component fails on a Radiant hot water unit within a further one 1 year after the end of the initial warranty period Dux will provide a full refrigerant parts replacement guarantee for these components at the nearest approved Dux agent or Dux office to the owner s home Under this replacement guarantee the transport installation and labour costs of delivering the replacement components will be responsibility of the owner of the existing water heater 5 Year Replacement Guarantee If an inner cylinder fails on a Radiant hot water unit within a further four 4 years after the end of the initial one 1 year warranty period Dux will provide a free replacement hot water unit at the nearest approved Dux agent or Dux office to the owner s home Under this replacement guarantee the transport installation and labour costs of delivering the replacement hot water unit and removing and replacing the existing hot water unit with the replacement hot water unit will be the responsibility of the owner of the existing hot water unit Scope of Warranty and Replace ment Guarantee In addition to the guarantees implied by the Australian Consumer Law ACL Dux provides a warranty for the periods of time set out above 1 year plus a further 4 years after the date of installation or manufacture of the hot water heater the Unit that the Unit is free from al
15. l be certain times of the day where there is insufficient hot water It is also advisable to inspect tap washers etc for leakage and replace if necessary High Electricity Bills e ls the Pressure amp Temperature Relief Valve discharging too much water e Is one outlet Such as the shower using more hot water than you think Is there a leaking hot water pipe or H3777 3777 Rev F 17 RADI ANT Owner s Manual Radiant Heat Pump HOT WATER Troubleshooting dripping hot water tap A small leak can waste a large quantity of hot water e Replace faulty tap washers and have your plumber rectify any leaking pipe work Condensation Is Dripping From Inside The Unit Check that the discharge location of the condensate drain has not been blocked thereby restricting the condensation flow away from the heat pump The Radiant Heat Pump Does Not Run Check that the power supply is turned on and that the house circuit breakers or fuses are on and operational 18 H3777 3777 Rev F RADIANT Owner s Manual Radiant Heat Pump HOT WATER System Maintenance The heat pump water heater is designed to eliminate system maintenance other than that detailed in this Owner s Manual Personally inspecting or servicing any part of the system is not recommended Should you decide to personally inspect the system it is essential that you observe all normal safety practices Most importantly the electricity suppl
16. l defects in factory materials or workmanship under normal use 22 H3777 3777 Rev F RADIANT Owner s Manual Radiant Heat Pump HOT WATER Warranty If the Unit fails to conform to this warranty during the applicable period Dux will replace any failed component or where necessary in the absolute discretion of Dux replace the Unit free of charge including reasonable labour costs incurred in normal business working hours Note Where the date of completion of installation is not known then this warranty will commence one 1 month after the date of manufacture refer to the data label on the Unit This warranty only applies to defects which have arisen solely from faulty materials or workmanship in the Unit and does not apply to other defects which may have arisen as a result of without limitation the following accidental damage abuse misuse maltreatment abnormal stress or strain harsh or adverse water conditions including excessive water pressure or temperature or neglect of any kind of the Unit Alterations or repair of the Unit other than by an accredited and licensed service agent or technician are not covered Attachment of accessories or use of non genuine replacement parts other than those manufactured or approved by Dux are not covered by this extended warranty This warranty applies only to the Unit and does not cover any ancillary plumbing or electrical parts supplied by the installer suc
17. n the water heater To dissipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not a dishwasher clothes washer or other appliance During this procedure there must be no smoking open flame or any other electrical appliance operating nearby If hydrogen is discharged through the tap it will probably make an unusual noise similar to air escaping What Should I Check Before Mak ing A Service Call If after checking the troubleshooting points in the following section the problem has not been identified please contact the distributor from whom you purchased the system Note It is important to know that there are no user serviceable components in the system and as such it is recommended that no covers be removed and no adjustments made to the system settings by anyone other than an authorised representative 16 H3777 3777 Rev F RADI ANT Owner s Manual Radiant Heat Pump HOT WATER Troubleshooting Pressure amp Temperature Relief Valve PTR It is not unusual for the PTR Valve to allow a small quantity of water to escape during the heating cycle The amount of discharge will depend on hot water usage Continuous Trickle PTR This is most likely due to a build up of foreign matter In this case try gently raising the easing lever on the Pressure amp Temperature Relief Valve for a few seconds then release gently This may dislodge
18. ncerning use of the appliance by a person responsible for their safety Children and animals should be supervised to ensure that they do not interfere with the appliance How Does The Heat Pump Module Work A heat pump uses complex thermodynamic principles to extract energy from ambient air and transfer this energy to water that is in contact with the unit s immersed heat exchanger The heat pump s operational principles are similar to those used in a normal domestic refrigerator except in reverse In a refrigerator heat energy is drawn from inside the refrigerator making things cold concentrated by the compressor then dissipated to the atmosphere via the condenser coil located on the back of the refrigerator cabinet In a Radiant Heat Pump system outside air is drawn into the unit and across an evaporator coil by a fan The evaporator coil captures the energy in the air and transfers that to cold liquid refrigerant contained inside the evaporator causing the refrigerant to increase in temperature and evaporate into a warm gas The warm gas on exiting the evaporator passes into a compressor where compression causes the temperature of the gas to increase further becoming a superheated hot gas The superheated gas is pumped from the compressor to a water immersed condenser coil where it gives up its heat energy to the water When the superheated gas gives up energy it condenses back to a liquid and on exi
19. ndensation will vary with the humidity of the location so the amount of condensate that flows from the module will also vary see the section on condensate drain page 18 H3777 3777 Rev F 15 Owners Manual Radiant Heat Pump RADIANT HOT WATER Owner s Instructions Does The Heat Pump Need Sun light To Operate Heat pump water heaters extract their energy from the surrounding air and not from sunlight For this reason they can efficiently produce hot water any time day or night and even on cloudy or overcast days It is not uncommon for your system to operate during the night Caution All water heaters have the ability to produce hot water in a surprisingly short time To reduce the risk of scald injury it is mandatory under the requirements of Australian Standards AS3500 that an Australian Standards approved temperature control valve be fitted to the hot water supply pipe work This valve should be checked at regular intervals to ensure its operation and settings remain correct What Should I Do During Holi days If you are going to be away for a week or more it is advisable to turn off the electricity supply to the system While there is no damage likely if the electricity is left on you will consume energy through storage tank heat losses which can be avoided Warning If the hot water system is not used for two weeks or more a quantity of hydrogen gas which is highly flammable may accumulate i
20. ng lever at least once every six 6 months may result in a problem with the water heater and in some cases the tank may explode 20 H3777 3777 Rev F RADIANT Owner s Manual Radiant Heat Pump HOT WATER Service Information Six Monthly Service By Owner Operate the Pressure amp Temperature Relief Valve for approximately 10 seconds by operating the easing lever on the valve to ensure water is relieved to waste through the relief drain pipe Check to ensure the valve closes correctly Five Year Service By Authorised Personnel Only The five yearly services should be carried out by a licensed tradesperson where it is recommended that this service be carried out by your local service agent The service should include the following e Replace the Pressure amp Temperature Relief Valve e Replace the anodes in areas of harsh or adverse water conditions it is recommended that you carry out a more frequent check of your anodes condition e Flush the water heater by doing the following i Turn off the power ii Turn off the cold water supply to the water heater at the isolating valve iii Gently operate the easing lever on the Pressure amp Temperature Relief Valve to release the pressure in the water heater iv Disconnect the cold water inlet union to the heater and attach a drain hose v Gently operate the Pressure amp Temperature Relief Valve to let air into the heater and
21. r compensation for any other loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure 24 H3777 3777 Rev F RADI ANT Owner s Manual Radiant Heat Pump HOT WATER Warranty Card Inside the water heater carton you will find a warranty card please fill in the details and return immediately This will ensure prompt service under warranty if required Product Warranty is applicable only in Australia and New Zealand See page 22 for terms of warranty Privacy Act Amendment 2000 If and whenever warranty service is required your personal details will be given to an Authorised Dux Service Agent only for the express purpose of carrying out the arranged warranty service work agreed by you the client and Dux Manufacturing Limited Your Details For future convenience fill in the following details and retain with your original invoice for your own records SUPMAMOH ss innne Saedadans caneaetaas teens Given Name S rinaire AJGrES Sinira ne e eae ern EAn ATANAN EAA DANENA Ea RAAE TOWS UDUM nnna odie ana TE a eN aaa EAE ONA aaa N EOG State Territory seeeeeeeee POSTCOQE iiini iiciin Date of PUrChaSe eee PurchaSed Fr i siira sssini aana IMOGISL Es csncuatanstatacesetescananes Serial NUMBSH astearen aaa a iah Date of MAMUTACTUIE fincanspyieuershernecenovarcdiiipsanensedvviesianiassbprnsednssarensethaagy a
22. r supply The Hotlogic control system will then check the unit s operating parameters If conditions are suitable and there is enough energy available in the surrounding air the fan and compressor will turn on The Radiant Heat Pump is self regulating so there are no internal adjustments to be made during commissioning The Radiant Heat Pump has a 30 second delay built in after the power is switched on before the compressor and fan come on Conditioning cycle When the Radiant Heat Pump is operated for the first time it runs through what is known as a conditioning cycle Once this has occurred it is important to conduct a draw off of hot water and allow the unit to re heat prior to testing water temperature Do the following 1 After filling the tank with water allow time for the initial heat up cycle 2 Once its first heat up cycle is complete empty approximately 60 litres of hot water from the tank through the PTR valve outlet 3 Then allow the water in the tank to re heat 4 Once the re heat cycle is complete measure the water temperature at the PTR outlet again 5 The temperature will be approximately 60 C If for any reason the Radiant Heat Pump does not start the water is cold or the Hotlogic unit is not displaying any LED lights an electrician should test that power is available to the heat pump Note There are no installer serviceable parts within the heat pump module H3777 3777 Re
23. re control of hot water delivery Safety This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children and animals should be supervised to ensure that they do not interfere with the appliance H3777 3777 Rev F RADIANT Owner s Manual Radiant Heat Pump HOT WATER Location The water heater should be located as close as possible to the most frequently used hot water outlet Ensure that the data plate is clearly visible and provide adequate access for service to the element thermostat relief valve and anode Note All models are equipped with 2 sacrificial anodes accessible through the top cover Allow 50 of the height of the water heater for clearance above to replace the anodes The water heater has a plastic base which is resistant to water damage but it is recommended that a concrete plinth be installed under the water heater to protect the heater when subjected to wet conditions and to allow free circulation of air A properly drained overflow tray must be used where property damage could occur from water spillage See AS NZS3500 4 2 for further details Note The warranty does not cover consequential damage due to leakage of the water heater Install
24. rity regulations e Outside Australia and New Zealand please refer to local plumbing and building codes and regulations e Notice to Victorian customers from the Victorian Plumbing Industry Commission this water heater must be installed by a licensed person as required by the Victorian Building Act 1993 Only a licensed person will give you a compliance certificate showing that the work complies with all the relevant Standards and only a licensed person will have insurance protecting their workmanship for 6 years Note This water heater and heat pump components are not suitable for pool heating All warranty is voided if the unit is laid on its side for storage or transport It must be stored and transported in a near vertical position at all times with no exceptions Installation Details This water heater is designed for direct connection to water supply pressures of no greater than 250 Litre Model 800kPa Where the mains pressure can exceed or fluctuate beyond the pressure shown above a pressure limiting device complying with AS1357 must be fitted in the cold water inlet supply This device must be installed after the isolating valve and set below the pressure shown above Note during periods of lower demand water pressure may increase Caution This water heater delivers hot water at temperatures exceeding 50 C Refer to AS NZS3500 and local regulations regarding the need for additional temperatu
25. t Pump will run longer in winter and at night when the outside air temperature contains less energy What Is The Radiant Heat Pump De Icing Function During colder temperatures below 0 C and dependant on the level of humidity ice can begin to form on the evaporator coil which has the potential to affect the system s performance Operating through the patented Hotlogic controller the system instinctively determines when conditions conducive to icing exist At this time the de icing process commences removing ice from the evaporator and allowing the Radiant Heat Pump to continue to heat water The de icing cycle interrupts the flow of heated refrigerant whilst still allowing the fan to run continuing to draw air through the louvres It is this airflow which de ices the evaporator Once de icing has occurred the system allows the refrigerant to flow and heating continues Why Is There Condensation Com ing From The Unit Condensation production is normal for all devices that use refrigeration principles Air conditioners are a good example of systems that produce water condensation Condensation occurs when relatively warm moist air passes through the cold evaporator Moisture contained in the air condenses deposits onto the evaporator fins then runs down into the drainage system located under the evaporator It is this water that you see flowing from the condensate drain of the system The amount of co
26. ting the condenser coil it passes through an expansion control valve TX valve The TX valve acts as an automatically adjusting tap that controls the amount of liquid refrigerant that is allowed to pass once more into the evaporator This is necessary to constantly match the amount of liquid entering the evaporator to the available energy in the air passing through the evaporator so that the entire liquid refrigerant that enters evaporates and exits as a gas only How Do I Operate The System The operation of your water heater is fully automatic so you only need to connect the water and electricity supply and then turn on the electricity The heat pump module is electrically connected to the storage tank and will start automatically when the water temperature in the storage tank falls below 55 C and continue to run until the water temperature of the complete tank 14 H3777 3777 Rev F Owners Manual Radiant Heat Pump RADIANT HOT WATER Owner s Instructions has been increased to 60 C or slightly above To condition the unit properly allow the heat pump to go through one heat up cycle before use in that case allow 24 hours before using the hot water How Long Will The Heat Pump Run Each Day The length of time that the Radiant Heat Pump will run each day will vary depending on the amount of hot water being used by the household and the average outdoor ambient temperature Generally the Radiant Hea
27. ts life expectancy If you are unsure about your water quality you can obtain information from your local water supply authority Water can also contain material known to create lime scale where lime scale can build up and block safety fittings One measure of this water quality is known as the saturation index if the saturation index is greater than 0 40 and therefore subject to lime scale an expansion control valve should be fitted to the unit H3777 3777 Rev F RADI ANT Owner s Manual Radiant Heat Pump HOT WATER Plumbing Connections Condensation Drain All heat pump water heaters will create condensation from the evaporator coil The more humid the air the more condensation it will create The evaporator coil in the Radiant Heat Pump is located at the top of the unit conforming to the outside of the tank When condensate is created it runs into the Condensate Tray which sits on top of the storage tank This then runs out through the Condensate Drain which is a feature of the tray A copper elbow is attached to this drain allowing easy access for the plumber to attach the condensate drain line away from the heater The Radiant Heat Pump louvre now incorporates a condensate drain cover to offer protection to the drain Copper elbow joined to the condensate drain Caution DO NOT braze the copper elbow to a condensate drain line as this will result in damage to the louvre section as well
28. v F 11 RADI ANT Owner s Manual Radiant Heat Pump HOT WATER Operational Diagrams Refrigeration View f Cut through View Main Component View 12 H3777 3777 Rev F RADIANT Owner s Manual Radiant Heat Pump HOT WATER Commissioning Checklist 1 The Radiant Heat Pump produces 4 Ensure there is no obstruction on water condensation so make sure the unit is installed on a flat surface and ensure you install a condensate drain from the condensate drain port down the side of the water heater Tempering Valves are a requirement ensure they are commissioned correctly Incorrect commissioning can lead to a lack of hot water delivery Make sure the all copper pipes are lagged with high temperature closed cell 18mm minimum insulation top of the Radiant Heat Pump that will block the air outlet When the system is turned on check that the Hotlogic unit inside the top cover is displaying the green power LED If it is not displaying the green power LED refer to the table of Hotlogic Operational Codes on page 9 to determine the best course of action H3777 3777 Rev F 13 Owners Manual Radiant Heat Pump RADIANT HOT WATER Owner s Instructions Safety This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction co
29. y must be turned OFF Every 5 years you should contact the local service agent to replace all safety valves and anodes to ensure continued system life and operational safety In locations where the potable water has a TDS greater than 600 ppm this service is recommended every 3 years H3777 3777 Rev F 19 Owners Manual Radiant Heat Pump RADIANT HOT WATER Safety Information For safe performance this water heater is fitted with e an over temperature energy cut out thermostat e acombination Pressure amp Temperature Relief Valve These devices must not be tampered with or removed The water heater must not be operated unless both of these devices are fitted and in working order The element cover should be removed only by an electrician The electrical power supply switch must be turned off and the fuse removed at the main electrical supply switchboard before the water heater s electrical cover is removed The Pressure amp Temperature Relief Valve should be checked for adequate performance or replaced at intervals not exceeding 5 years or less in areas where local regulations apply The lever on the relief valve should be pulled to operate the valve at least once every 6 months Note The pressure amp temperature relief valve and the drain outlet pipe must not be sealed or blocked It is normal for the valve to overflow during heating cycles Danger Failure to operate the relief valve easi