Owners Manual - Bianco Pumpz

image

Contents

1. Pump Manual s Jaze T a b chy Se Y L SSS a Z sc 99 G L 2l i c K b EL S j ja E x L IL has A Ar S i i E Y FOE du AA R L j Ss s g S Dy EI az H PA 1 Ji H l K j L E For your protection please read these important instructions first A WARNING This equipment must be installed and serviced by a qualified technician Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty GENERAL SAFETY RULES 1 The products mentioned in this manual are specially designed for the pre filtering and re circulation of water in swimming pools and spas 2 They are designed to work with clean water at a temperature not exceeding 40 C 3 Any modification of the pump requires the prior consent of the manufacturer Original replacement parts and accessories authorized by the manufacturer ensure a high level of safety The manufacturer of the pump assumes no liability for the damage and injuries caused by un authorised replacement parts and accessories 4 During operation some parts of the pump are subject to dangerous electric voltage Work may only be performed on each pump or on the equipment connected to it after disconnecting them from the main power and after disconnecting the starting device 5 The user should make sure that assembly and maintenan
2. OMS PROBABLE CAUSE WHAT TO DO Pump will not prime Suction air leak Make sure water level is correct through suction points Ensure baskets and strainers are free of debris Tighten all fittings unions on the suction side of the pump remove and replace mechanical seal No water in the pump Make sure the filter tank if full Closed valves or blocked lines Open all valves in system clean skimmer and pump basket check pump impeller of blockage Motor will not run No power to motor Check that all electrical switches are on Ensure the circuit breakers are properly set Check if timer is set properly Check motor wiring at terminals Pump jammed With power switched off turn pump shaft this should spin freely Low flow Dirty filter Backwash or clean cartridge Dirty skimmer strainer and pump Clean skimmer and pump strainer Suction air leak Replace pipe work Closed valve or blocked line Open valve or clear blockage Motor runs hot Low or incorrect voltage Supply to be correct by electrician Motor running hot to touch is normal Thermal overload protector will function to turn them off if there is an overload or excessive high temperature problem Installed in direct sunlight Protect the pumps from the elements Poor ventilation Do not tightly cover or enclose motor Noise pump operation Bad Worn bearing Have an electrician repl
3. ON based grease only if needed If it is damaged please replace 4 Replace the strainer 5 Re prime the filter tank 6 Correctly locate the o ring 7 Replace the lid hand tighten only 8 Switch on pump In Climates where the pump may be exposed to frost or freezing care must be taken to ensure the pump is protected from damage It is recommended that if the pump is not used during the winter period it should be drained completely and stored in a dry location Do not replace the drain plug Store it in a safe place when not use An example would be store plug in the filter tank basket When you re activate the pump after a period of rest ensure all seals and o rings are in operational condition re grease if necessary replace if unsure of condition Check that the motor shaft moves freely before re activation AWARNING 1 When connecting electric cables to the motor of the pump be careful to correctly arrange them inside the connection box verify that no bits of cable are left inside the box on closing it See that the ground wire is correctly connected When connecting the motor follow the wiring diagram supplied with the pump 2 Be especially careful that no water enters the motor or electrical parts under voltage 3 In the event that the planned use is not as specified adaptations and supplementary technical rules may be necessary 4 Before starting the pump verify the calibration of the electrical pro
4. ace Air leak in suction Replace suction hose Suction blockage Locate and clean blockage Disturbance in impeller Contact supplier Cavitations Improve suction reduce suction lift reduce number of fittings increase pipe size increase discharge pressure and reduce flow by throttling discharge valve Motor overload Motor not connected Have electrician check wiring cuts out properly Voltage at motors should be no more than 6 above or below Low incoming voltage nameplate voltage Have electrician check voltage ensure pump is not running on an extension cord Report low supply to authorities Over load due to binding in pump or wrong size Contact supplier impeller AWARNING If the pump is within the stated warranty period and you experience faults always contact your supplier Failure to do this may void warranty Refer to warranty documentation supplied with pump All electrical work is to be carried out by a Qualified Electrician under no circumstances should you attempt repairs on the electrical components of pumps unless you are qualified to do so
5. any local electrical codes Every motor requires either a fused disconnect switch or a circuit breaker A SINGLE PHASE MOTOR has a built in thermal overload switch PRIMING The pump will prime and re prime providing the filter tank water and there is sufficient supply from the suction point If you lose water from the filter tank it will be necessary to re fill it before starting 1 Remove the translucent lid and fill the filter tank with water 2 Replace the lid ensuring the o ring is correctly located and start the pump After you have done this allow a few minutes maximum running for the pump to start delivering water AWARNING High suction lift or long suction lines will require additional time to prime and can severely affect the performance of the pump If the pump will not prime repeat step 1 and 2 above Mechanical seals may need to be replaced if the pump is run without water ENSURE that there is always adequate water in the filter tank before you start up If you are unable to prime the pump please see the trouble shooting guide ENSURE that all suction and discharge valves are open before you start the pump otherwise this will result in damage to the pump MAINTENANCE The strainer basket in the filter tank should be inspected and cleaned at regular intervals 1 Remove lid and lift out basket 2 Remove debris and hose off with clean water if necessary 3 Inspect the lid gasket lubricate with SILIC
6. ce tasks are carried out by qualified authorized persons and that these persons have first carefully read the instructions for service and installation 6 The operating safety of the pump is only guaranteed if the installation and service instructions are correctly followed 78 In the event of defective operation or fault contact the technical support department of the manufacturer or its nearest authorized agents 9 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person to avoid a hazard 10 The pump must not be used when people are in the water 11 The pump must be supplied through a residual current device RCD having a rated residual operating current not exceeding 30mA 12 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 13 Children should be supervised to ensure that they do not play with the appliance 14 The pump must be protected from running dry LOCATION The pump must be installed and placed to an enough distance away from the pool or water source to avoid the water from the pool or water source to avoid the water pouring or flowing onto the pump The pump must also be in a position that enables easy access for p
7. eriodic servicing Care must also be taken to position the pump in an area that is free from flooding in a well ventilated and dry area Protect the pump from the elements INSTALLATION A few simple precautions during installation will ensure years of trouble free operation 1 The pump suction line should not be smaller than 1 1 2 40mm imperial or 50mm true metric 2 The suction line is to have as few bends or elbows as possible There must not be an air trap on the suction line 3 Installation shall arrange on a solid flat foundation with the pump bolted securely to it 4 The pump electrical cable must be wired for the proper voltage and current in accordance with the wiring instructions 5 All wiring electrical work must be carried out by licensed electricians and must be installed in accordance to the local codes and standards 6 The motor must be grounded The weight of any pipe work and fittings is to be independently supported and not carried by the pump 8 The maximum total head Hmax of the pump in metres shown on the pump label should be noted by the installer 9 The permissible temperature is gt 0 C and lt 40 C fluid temperature The pump should never be operated outside of these temperatures or damage may occur N ELECTRICAL CONNECTION Check that the information on the nameplate corresponds to the power supply Employ a competent electrician to ensure wiring installation is made in accordance with
8. tection devices of the motor and that the protections against electrical and mechanical contacts are correctly positioned and attached 5 It is advisable to follow the steps listed below before handling the pump in any way 8 Turn off the voltage to the pump b Lock starting devices C Verify that there is no voltage in the circuits including ancillary devices and auxiliary circuits d Wait until motor stops completely ma er a The above list should be considered indicative and not binding for the purpose of safety specific safety rules may exist in particular regulations INSPECT ON A REGULAR BASIS 1 The correct attachments of the mechanical parts and of the support screws of the pump 2 The correct position attachment and condition of the supply cables and of the insulating parts 3 The temperature of the motor In the event of any excessive high stop immediately and have it repaired 4 The vibration of the pump In the case of any excessive high stop immediately and have it repaired ACAUTION Owing to the complexity of the cases covered the instructions for installation use and maintenance contained in this manual do not attempt to examine all possible and imaginable cases of service and maintenance If supplementary instructions are required or if special problems arise do not hesitate to contact the distributor or to address directly the manufacturer of the pump TROUBLE SHOOTING SYMPT