User's Guide Models 475055 Digital Force Gauge
Contents
1. Las especificaciones del producto est n sujetas a cambios sin aviso Por favor visite nuestra p gina en Internet para la informaci n m s actualizada www extech com FLIR Commercial Systems Inc 9 Townsend West Nashua NH 03063 USA Certificado ISO 9001 Copyright O 2014 FLIR Systems Inc Reservados todos los derechos incluyendo el derecho de reproducci n total o parcial en cualquier medio www extech com 8 475055 EN v2 5 3 14
2. M5 x 0 8mm ISO mounting screws included Holes are 60mm apart 5 475055 EN v2 5 3 14 Warranty FLIR Systems Inc warrants this Extech Instruments brand device to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies to sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department for authorization Visit the website www extech com for contact information A Return Authorization RA number must be issued before any product is returned The sender is responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or unauthorized modification FLIR Systems Inc specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages FLIR s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Calibration Repair and Customer Care Services FLIR Systems Inc offers repair and calibration services for the Extech Instruments pr
3. must be in line with the object being measured Avoid rotating the sensing head Refer to the Figure 1 Figure 1 Correct and Incorrect Angles of Measurement Be Sind Acceptable Not Acceptable Measurement Mode 1 QA o Slide the POWER switch to the ON l position Reverse the LCD display if desired via the Display Reverse key Zero the meter before each measurement Touch the adapter to the object being measured in a straight line Refer to Fig 1 Begin measurement by applying force Push or Pull Read the LCD display After completing the measurement the display will indicate 0 00 if the position and angle of the Force Gauge have not changed Note Be sure to press ZERO before taking a new measurement Overrange Indication The Model 475055 uses a strain gauge sensor to measure force Avoid subjecting the instrument to forces outside the specified measurement range The sensitive strain gauge can be damaged or otherwise compromised by misuse When an over range condition is sensed by the meter the LCD displays all dashes Note that the dashes are shown at the top of the LCD for tension measurements and at the bottom of the display for compression measurements 3 475055 EN v2 5 3 14 Peak Load Measurement Slide the POWER switch to the PEAK position Touch the adapter to the object being measured in a straight line refer to Fig 1 Zero the meter before each measurement Begin measure
4. un service la client le Veuillez vous reporter aux coordonn es fournies ci dessous Lignes d assistance tats Unis 877 439 8324 international 1 603 324 7800 Service d assistance technique Option 3 E mail support extech com R parations et retours Option 4 E mail repair extech com Les sp cifications produit sont sujettes modifications sans pr avis Pour les toutes derni res informations veuillez visiter notre site Web www extech com FLIR Commercial Systems Inc 9 Townsend West Nashua NH 03063 USA Certifi ISO 9001 Copyright O 2014 FLIR Systems Inc Tous droits r serv s y compris la reproduction partielle ou totale sous quelque forme que ce soit www extech com 7 475055 EN v2 5 3 14 Garant a FLIR Systems Inc garantiza este dispositivo marca Extech Instruments para estar libre de defectos en partes o mano de obra durante un a o a partir de la fecha de embarque se aplica una garant a limitada de seis meses para cables y sensores Si fuera necesario regresar el instrumento para servicio durante o despu s del periodo de garant a llame al Departamento de Servicio a Clientes para obtener autorizaci n Visite www extech com para Informaci n de contacto Se debe expedir un n mero de Autorizaci n de Devoluci n AD antes de regresar cualquier producto El remitente es responsable de los gastos de embarque flete seguro y empaque apropiado para prevenir da os en tr nsito Esta ga
5. User s Guide EXT INSTRUMENTS Models 475055 Digital Force Gauge Introduction Congratulations on your purchase of Extech s Model 475055 Digital Force Gauge that measures Tension or Compression pull push to 220 lbs It features Peak hold fast slow response time positive or reverse display direction and a separate sensor An RS 232 PC interface provides data acquisition functionality This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Meter Description SO NS BW N Sensor socket LCD display Keypad Kg N lb switch Off On Peak switch Sensor plug Sensor loop S type load sensor p MN Sensor hook orriren ST Mounting holes 60mm apart Force Gauge 475055 2 475055 EN v2 5 3 14 Operation Preparation for Measurement 1 2 3 4 5 Note The 475055 automatically determines Tension or Compression pull push force during use Compression displays as a negative value and Tension displays as a positive value Select units of measure kilograms pounds or Newtons via the units select switch Screw in the sensor hook and loop on the load sensor and then connect the sensor to the meter via the input jack on top of the meter Select FAST 0 2 seconds or SLOW 0 6 seconds update rate Zero the display before each measurement via the Zero button The sensing head with adapter
6. e battery cover Replace with six 6 1 5V AA batteries Replace compartment cover and screws Range 220 lbs 100kg 980 Newtons Accuracy 23 C 0 5 rdg 0 1Ibs 0 1kg or 0 4N Resolution 0 05lbs 0 05kg 0 2 Newtons Overload Capacity 150kg Circuit Custom LSI microprocessor Zero adjust Button for Peak Hold and normal display zero Display 5 digit LCD type Digit height 0 63 16 mm Update Rate Fast mode 0 2 seconds Slow mode 0 6 seconds Over range Indicators LCD displays for tension measurements and ___ for compression measurements Zero Tare Control Up to Maximum capacity Full Scale Deflection lt imm Transducer type S type load cell with 2 hooks thread size M6 x 1mm ISO and 6 5 ft 2m cable Peak Hold Freezes Max reading on display Data Output RS 232 serial interface with 16 bit data stream output Operating Temperature 32 F to 122 F 0 C to 50 C Operating RH Max 80 Relative Humidity RH Power Supply 6 x 1 5V AA batteries or 9VDC adapter not included Power consumption 28mA approx Weight Meter 1 Ib 450g Sensor 0 84 Ibs 380g Dimensions Meter 8 5 x 3 5 x 1 8 215 x 90 x 45 mm Sensor with 2 hooks 5 7 x 2 0 x 0 6 145 x 51 x 15 mm Cable length 6 5 ft 2m Test Stand Mounting Holes Located on rear thread size
7. ment by applying force pull or push The LCD will display the peak value which is the highest reading encountered 5 After completing the measurement the display will hold the peak reading until a higher reading is reached or the switch is moved out of the peak hold position Note Be sure to press ZERO before taking a new measurement SN a Fast Slow selection Press the FAST SLOW key to select the desired display update rate The FAST icon will appear in the display when FAST is selected Mounting For best results mount the Digital Force Gauge to a test fixture Mounting holes are provided on the rear of the meter for use with fixtures and test stands Display Backlight Pressing the backlight button momentarily will turn on the backlight After approximately 15 seconds it will automatically shut off RS 232 PC Interface The 475055 is equipped with a 3 5mm phone jack meter bottom for connection to a PC for data acquisition purposes For streaming of data to a PC via the RS232 Output jack the optional 407001 USB kit RS232 to USB cable and driver CD along with the 407001 software available free at www extech com are required 4 475055 EN v2 5 3 14 Maintenance Battery Replacement The low battery indication appears as a LO on the display when battery voltage is less than 6 8V To replace the battery ON Specifications Remove the two screws from the battery compartment cover Lift off th
8. oducts we sell NIST certification for most products is also provided Call the Customer Service Department for information on calibration services available for this product Annual calibrations should be performed to verify meter performance and accuracy Technical support and general customer service is also provided refer to the contact information provided below Support Lines U S 877 439 8324 International 1 603 324 7800 Technical Support Option 3 E mail support extech com Repair amp Returns Option 4 E mail repair extech com Product specifications are subject to change without notice Please visit our website for the most up to date information www extech com FLIR Commercial Systems Inc 9 Townsend West Nashua NH 03063 USA ISO 9001 Certified Copyright O 2014 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form www extech com 6 475055 EN v2 5 3 14 Garantie FLIR Systems Inc garantit que cet appareil Extech Instruments est exempt de d fauts mat riaux et de fabrication pendant un an partir de la date d envoi une garantie limit e de six mois s applique aux capteurs et aux c bles Si le renvoi de l appareil pour r paration devient n cessaire durant ou apr s la p riode de garantie contactez le service client pour autorisation Pour obtenir les coordonn es visitez le site Web suivant www extech com Un num ro d autorisation de ret
9. our AR doit tre d livr avant tout retour de produit L exp diteur prend sa charge les frais d exp dition le fret l assurance et l emballage correct de l appareil afin de pr venir toute d t rioration durant le transport Cette garantie ne s applique pas aux dommages imputables l utilisateur tels que l usage impropre ou abusif un mauvais c blage une utilisation non conforme aux sp cifications un entretien ou une r paration incorrecte ou toute modification non autoris e FLIR Systems Inc d clinera sp cifiquement toute garantie ou qualit marchande ou aptitude l emploi pr vu et ne sera en aucun cas tenu responsable pour tout dommage cons quent direct indirect ou accidentel La responsabilit totale de FLIR est limit e la r paration ou au remplacement du produit La garantie d finie ci dessus est inclusive et aucune autre garantie crite ou orale n est exprim e ou implicite Calibrage r paration et services apr s vente FLIR Systems Inc offre des services de calibrage et de r paration pour les produits Extech Instruments que nous commercialisons Nous fournissons galement une certification NIST pour la plupart des produits Contactez notre service client pour toute information sur les services de calibrage disponibles pour ce produit Un calibrage doit tre effectu chaque ann e pour v rifier les performances et la pr cision du m tre Nous offrons galement une assistance technique et
10. rant a no se aplica a defectos resultantes de las acciones del usuario como el mal uso alambrado equivocado operaci n fuera de las especificaciones mantenimiento o reparaci n inadecuada o modificaci n no autorizada FLIR Systems Inc rechaza especificamente cualesquier garant as impl citas o factibilidad de comercializaci n o idoneidad para cualquier prop sito determinado y no ser responsable por cualesquier da os directos indirectos incidentales o consecuentes La responsabilidad total de FLIR est limitada a la reparaci n o reemplazo del producto La garant a precedente es inclusiva y no hay otra garant a ya sea escrita u oral expresa o impl cita Servicios de calibraci n reparaci n y atenci n a clientes FLIR Systems Inc ofrece servicios de reparaci n y calibraci n para los productos que vendemos de Extech Instruments Adem s ofrecemos certificaci n NIST para la mayor a de los productos Llame al Departamento de Servicio al Cliente para solicitar informaci n de calibraci n para este producto Para verificar el funcionamiento y precisi n se debe realizar la calibraci n anual Adem s se provee Soporte T cnico y servicios generales al cliente consulte la informaci n de contacto en seguida L neas de soporte EE UU 877 439 8324 Internacional 1 603 324 7800 Soporte T cnico Opci n 3 correo electr nico support extech com Reparaci n Devoluciones Opci n 4 correo electr nico repair extech com