1. To enable Chime Zone Press lt CONTROL gt and lt PROGRAMS gt S key again Note When the system is armed it changes to become a full alarm zone 2 Output Control Outputs are programmable contacts on the panel that can be used to switch power or external devices on or off Press the CONTROL key Program and System LED s will be on steady Press the number key corresponding to the output you wish to turn on i e output 3 turns on water heating Press the 3 key the 3 LED will illuminate indicating the output is on Press the ENTER key to return to normal keypad function To check what outputs are on simply press the CONTROL key again LED 3 will be illuminated pressing the 3 key again will toggle the output off Press ENTER to return keypad to normal The MONITOR Key Monitor mode allows you to monitor areas you will not be in at night Pre selected zones or sensors can be armed with this key while you are in the building and programmed to go into your choice of alarm states if triggered As with everything else on the panel this too can be tailored to your needs For example you may wish to have the detectors in your garage and lounge sound only a little buzzer by your bed at night to warn you of an intruder To use this feature press the MONITOR key and if programmed to do so the exit delay will sound The armed light on the keypad will flash To disarm press the MONITOR key again The PW 8 can be programmed to req
2. Delay Monitor Mode ae e E E e E Chime EE Ji fed a E Master Code les i it i eg J EVENT DEVICE INDICATOR STATUS WIRELESS ZONE LOW Wireless PIR LED s 1 8 Flashing BATTERY Zone 1 8 REMOTE CONTROL Remote Control Button TROUBLE On Steady LOW BATTERY 1 8 LED s 1 8 Flashing PANIC BUTTON Keypad Panic SYSTEM Flashing BUTTONS 1 amp 3 PRESSED TOGETHER FIRE ALARM Keypad Fire SYSTEM Flashing BUTTONS 4 amp 6 AREA A Flashing PRESSED TOGETHER MEDICAL ALARM Keypad Medical SYSTEM Flashing BUTTONS 7 amp 9 AREA B Flashing PRESSED TOGETHER PENDANT PANIC Radio Key SYSTEM Flashing User 1 8 LED s 1 8 Flashing ARMED A Area A Armed AREA A LED On Steady ARMED B Area B Armed AREA B LED On Steady MONITOR MODE A Area A Monitor Mode AREA A LED Flashing ON MONITOR MODE B Area B Monitor Mode AREA B LED Flashing ON DURESS ALARM Duress Alarm TROUBLE On Steady AREA A amp B Flashing Installation Notes INSTALLTION COMPANY Company Technician Phone Installation Date Another special key that can be programmed to control a number of functions 1 Chime Zone Control A Chime Zone is a detector that can be part armed while you are home but working in another part of the building It can be programmed to operate a buzzer or light to let you know you have a visitor Press the CONTROL key Program and System LED s will be on steady Press the PROGRAM key Program LED will flash indicating that Chime Zone is disabled
3. OUTPUTS Output 1 Output 2 Output 3 Output 4 Siren Time minutes COMMUNICATION OPTIONS Monitoring O Domestic O Speech O Power Wave 8 SERVICING PO 8 Zone Alarm Panel Can your system be serviced by another technician O If yes Installer Code SERVICING NOTES USER GUIDE 25 Oct 2001 Please contact your alarm installer if you require further information About your Alarm System Thank you for choosing to protect your premises with an PowerWave 8 PW8 In doing so you have invested in the most advanced and adaptable panel on the market As you become familiar with your PW 8 ask your installer about the incredible program options and additional expandability of your PW 8 Alarm Controller Your new panel is ready to give you years of trouble free operation and can be custom programmed to your specific needs Add on features like the RX 40 wireless receiver card to operate any of the 4 outputs and the arm disarm of your panel with up to 8 key fob wireless pendants or add wireless detectors at any stage The auto dialler on your panel can be set up to send high speed signals to a monitoring station and or domestic dial sending an Alarm tone to any or all of the 4 possible phone numbers The Keypad Your PW 8 Alarm Controller has been designed with you in mind Clearly named backlit keys may cost a little more but mean you don t have to remember multiple key combinations to achieve a result As wit
4. h everything about the PW 8 even key functions can be fine tuned to your specific needs Please ask your installer Arming Your System Press the ARM to arm your system the Armed light will come on Your panel will begin beeping it s exit delay During this time it is optional to press the ARM key again to disarm to prevent accidental arming the panel can be programmed to require a code to arm To do so enter your code followed by the ENTER key Disarming Enter your 1 to 6 digit code then press the ENTER key If your system has the wireless receiver installed your system can also be armed or disarmed with your remote key fob pendant Panic This special key s function is best programmed by your installer to suit your individual situation Most commonly it is used in a panic situation to sound only the outside siren and perhaps call a monitoring station A panic command can be instant or your installer can program a 2 second delay to prevent false alarms A Panic can also be triggered by a dedicated Monitor Mode Keypad or a Remote Control button programmed as instant or delayed panic The CONTROL Key MONITORING COMPANY Account Number Phone USER CODES 1 Code 2 Code 3 Code 4 Code 5 Code 6 Code 7 Code 8 Code 9 Code 10 Code ZONES Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Name Name Name Name Name Name Name Name Name Name Passcode
5. hat address it will be flashed back on the key pads LED display Entering the new code will delete the old and the new code will be flashed back to you 4321 ENTER The panel will give 3 short beeps to indicate correct entry or 1 long tone if not accepted To remove or clear a user code number e g user 3 key in the following sequence PROGRAM 3 ENTER EXCLUDE ENTER To exit out of program mode key PROGRAM ENTER Note on the LED display 0 is indicated by LED A and 9 by LED B Event Memory Your PW 8 alarm panel has an event memory which stores the 127 most recent events including all alarm events and system events such as mains failure etc as well as sets The System LED will flash when an event occurs e g mains failure When the event is cleared mains returns the system LED will remain steady To clear this indicator press MEMORY or it will simply clear next time you arm the panel The Trouble LED will flash when an alarm occurs e g Tamper Alarms When the alarm is cleared by entering a valid code the Trouble LED will turn off If the reason for the alarm is not cleared the Trouble LEDwill remain on solid until the cause is found and cleared fully
6. ren LOW BATTERY Alarm Backup Battery SYSTEM On Steady LED 1 On Steady MAINS FAILURE Alarm Mains Supply SYSTEM On Steady LED 2 On Steady continued over leaf This event memory is displayed via the keypad with the most recent event shown first and subsequent events following in descending order from newest to oldest Each event is separated by a beep tone There are a number of events which are stored in memory which do not have a specific indicator associated with them such as Panic and Duress Other events such as tampers and low battery are shared across many devices For this reason the following table has been created This table details which indicator lights correspond to which events in memory To enter View the EVENT MEMORY Press the MEMORY button The last 127 events will be played back on the keypad LEDs displayed sequentially at 2 second intervals from the most recent event backwards To get to a specific event rapidly press the MEMORY key repeatedly and the memory display will be sped up accordingly To exit memory mode press ENTER Making sure the panel is not armed key in the following sequence PROGRAM mastercode ENTER The program light will come on steady indicating readiness to accept new programming To load for example user code 3 with a code 4321 key in the following sequence Add further user codes from 2 up to 10 if required PROGRAM 3 ENTER If there is an existing code already in t
7. t user codes of 1 up to 6 digits in length Your installer can set you up to enter your code at user code 1 Master code You will now be able to add delete or change codes for other users To add a new user code By default only the master code has access to change add or remove codes Any new codes added will be able to arm disarm and put either area of the panel into monitor mode User codes can be limited in their levels of Access if required See your installer If the System light is on but no other Zone lights are there are no current System alarms Arming Disarming or reviewing the Memory will turn it off When viewing the memory by pressing the MEMORY button the first thing that will always be displayed are CURRENT SYSTEM FAULTS Below here are the System fault indications Zone LED System Fault 1 Battery Low Mains Failure Ce o ee l Telephone Line Failure Co eer Tow Co ee tow 8 tes Det Senn Fate Following the display of current system alarms the panel will then sequence through the 127 historical memory events starting at the most recent event VIEWING THE MEMORY EVENT DEVICE INDICATOR STATUS ACTIVATION LED s 1 8 On Steady EXCLUDE Zones 1 8 READY EXCL On Steady LED s 1 8 On Steady DETECTOR TAMPER Zones 1 4 TROUBLE Flashing SHORT CIRCUIT LED s 1 4 On Steady DETECTOR TAMPER Zones 5 8 TROUBLE Flashing OPEN CIRCUIT LED s 5 8 On Steady CABINET TAMPER Cabinet or External TROUBLE Flashing Si
8. uire your user code and pressing ENTER to disarm The EXCLUDE Key This key allows you to temporarily exclude or by pass zones of your choice when arming your panel The excluded zones will go back to normal the next time you disarm the panel except 24 Hour zones which must be manually re included A typical example would be if you wanted to let your pet run around in the garage when your system is armed you could choose to exclude that detector say Zone 1 from the system To exclude zone 1 key in the following sequence EXCLUDE Ready Exclude and Program LEDs will illuminate 1 ENTER When the ENTER key is pressed the Ready Exclude LED will flash to indicate the exclude function is active before arming any number of zones may be excluded in this manner Key in EXCLUDE again to add or remove excluded zones Key the 1 again and zone 1 will be included lt ARM gt NOTE 24 hour zones for example smoke detectors will remain excluded until they are manually included again All other excluded zones will return to normal included mode automatically the next time the panel is armed It is advisable to vacate the secured area before the exit delay expires The ENTER Key This key is used to accept a series of button presses Note If you make a mistake while entering your code press the ENTER key and start again The PROGRAM Key This key is used to get into program mode The PW 8 can accept as many as 10 differen

Download Pdf Manuals

image

Related Search

Related Contents

21,000円 126,000円 2,100円 6,300円  StarTech.com 5.25in Bay Mounted 2.5in/3.5in SATA HDD Docking Station  e - Forms User Manual ( New License for Private Employment  Energy Data Logger - HomeSystems Legrand  P.T.C.D.セット(造影針)  Automatic charger for 12V lead/acid batteries  HTC Touch Cruise Black  HP ProtectTools  Mirage Loudspeakers OmniVibe Stereo System User Manual  Spire PowerCube 710  