Home

0.07.B.0001 R3 R5 User Guide-10Jul2012-NG

image

Contents

1. Checkforcorrosion ofthe battery terminals Clean and apply grease as necessary CP75 Controller Battery 12V 7A H CP84ER5VO1 Charger nn A z os J Fuse 250mA Size 5x20mm Battery Charger In domestic applications the R3 and R5 are battery driven Each system has a built in battery charger which automatically maintains the battery in a fully charged state The casing may get hot when the chargeris in operation This is quite normal and is no cause for concern The small green light LED on the CP75 controller marked CHARGER ON should be illuminated at all times This light indicates that the electricity supply from the charger unit is switched ON NB Itdoes not indicate thatthe charger is charging correctly and therefore itis good practice to have the charging rate of the unit checked from time to time This is particularly important in areas which are prone to lightning or mains supply surges Specification of Charger No load charge voltage measured at battery terminals with battery disconnected 13 6 to 13 8 volts DC Charge rate under full load 1 amp Solar Panel Ensure that the panel is cleaned regularly excess dirt dustand leaves collecting on top of the panel will reduce it s efficiency Cutback any vegetation ortrees thatare shielding the panel from the sun Page 17 Specifications SPECIFICATION R3 Voltage with CP84ER5V01 power supply unit 220 240V AC 10 50Hz AC Current draw with CP84ER5VO1 power sup
2. After this time the gate system can be reactivated but will shutoff immediately again ifa battery low condition persists CONTACT YOUR LOCAL GATE AUTOMATION SPECIALIST OR Centurion Systems Pty Ltd IF YOU DISCOVER THAT THE BATT LOW SIGNAL GIVEN BY THE LED INSIDE THE HOUSE CONTINUES TO RE OCCUR Page 11 If the gate status indicator has not been fitted there is an equivalent LED mounted on the CP75 marked STATUS which can be used as a faultfinding aid N NOTE The controller s battery low protection will ensure that only the motors are prevented from drawing currentfrom the battery Items such as the radio receiver nfrared beams etc continue to flatten the battery An optional battery low cut out switch product code CP107 is available which will totally disconnectthe battery Security C ourtesy Light Timer optional feature If a 220 240V power supply is available at the gate timed security lights can be connected through the controller Each time the gate is given a signal to operate the lights will switch on for approximately two minutes and automatically switch off The time that lights Stay on can be programmed from 10 seconds to 42 minutes in increments of 10 seconds If security lights are fitted to the controller and the pedestrian keyswitch is operated the security lights will flash twice before the gate opens the preflash time is adjustable A pushbutton can be connected to the CP75 controller which will al
3. key counter clockwise until the Rotate the dust cover back into position top of the screw is flush with the top of the shaft Lower the controller housing into position not Replace the operator cover and lock it in position necessary for a SLAVE motor Page 15 Basic Maintenance The CENTSYS system is designed to be maintenance free However there are some basic checks that Should be carried out regularly every six months which will increase the long term reliability of the system and preventfalse triggering ofthe protection systems leading to erratic operation of the gate IMPORTANT ISOLATE MAINS SUPPLY TO SYSTEM BEFORE CLEANING OR WORKING ON THE EQUIPMENT NB The battery driven operators will continue to operate due to the internal battery 1 Remove all shrubs and vegetation which may interfere with the motors orlinkages 2 Keep the inside of the motors and control housings clear ofinsects and dirt 3 Grease the gate hinges to ensure that the gate swings freely 4 Check that the padlocks can be opened Apply oil or grease to the padlocks particularly during the rainy seasons Page 16 Battery AllCENTSYS domestic systems are fitted with a maintenance free lead acid battery thatshould provide at leastthree years of uninterrupted operation In the case of a 35A h battery ensure thatthe level of liquid electrolyte level is correct NB Due to its size the 35A H will be housed in a separate enclosure
4. signal to the receiver mounted in the control enclosure to open orclose the gate e Press once for approximately 1 second to getthe gate into motion e Ifthe transmitter is pressed while the gate is either opening or closing the gate will immediately stop Pressing the button again will cause the gate to reverse Ifthe automatic closing facility has been selected and the gate is closing automatically then the gate will stop and stay in that position if the transmitter is pressed Pressing the button again will cause the gate to reopen Page 6 Ifthe gate is opening with the automatic closing facility selected and the transmitter is then pressed the gate will stop but will close automatically after the Autoclose delay time Intercom Push button Optional l Vi 4 Ya Press to open gate A visitor outside the gate requests entrance Gate opened from intercom pushbutton inside house Mostautomatic gate installations are fitted with an intercom which provides for communication between the house and the gate The intercom handset is usually provided with a GATE or DOOR RELEASE pushbutton which when pressed sends a signal to the gate controller to open the gate The sequence of operation of this pushbutton is identical to the operation when using the radio transmit teras described above REVERSING MODE The system offers an alternative Mode of Operation to the above Referred to as Reversing Mode if the transmitter
5. three times activated per2seconds Check that the battery is charging Check thatthe mains supply is connected and switched on e Touch the side of the charger unit it should be hot if the battery is charging Check battery connections are tight and that there is no Page 19 SYMPTOM ACTION corrosion When was the battery last changed t t The life span of the 7A H maintenance free battery supplied with the system is typically up to three years e Motor fuse blown on the control card e Gate does not operate but the relays on the controller click momentarily e Battery voltage is low e Gate lock not releasing applies to typically single gate installations where a solenoid or magnetic lock has been fitted Replace blown fuses R3 8Amp slow blow Size 5x20mm Make sure thatthe motor fuse holders are making good contact See action earlier in this troubleshooting guide for battery voltage is low and the battery low protection is being activated Solenoid lock check thatthe lock is trying to release it will make a distinctive click sound when energised Then check that the lock is not being mechanically held due to misalignment dirtetc Magnetic lock Pull on the lock when activating the gate to release and feel whenever the lock is releasing Try disconnecting the lock remove the wire from terminal 13 Consult your installer if the problem persists e Gate d
6. CENTSYS i ROTARY SWING GATE OPERATOR Table of Contents Company PROMS vice cach aun ce kisten bam eee Reeds Rhee dae ee meee ie ee 3 MOCC u nah ae ae hae oa eee anne Reese ees pene ten se en au eeeeee eee ss 4 Sole NS TUCO sireeni nene oe eae eros Pa een oe ed oe a 4 a OR ROT rear ee a Booed eee oes SLRS aed ee ed Pee a 5 POSES cer UNCUONS naar bh aah Fa oa ee se dee eee 6 dange olt oiio ia en nn ee aan eek eee Senne radar es acces EE E EEE 6 Modes of OBEREN 2 ee an dai Des anne 6 Standard Mode Of OBelauon es sxcantd eurer ee rer ess 6 Radio Wane Wiel ss ee ee a ee ea oy Seen ee ee Dear 6 INES IN PUSNDUWON err faeces ee dhe edhe aot lps et ad ee eee eae 7 Revena MOUS euere E nn oad Ok wee oe es Ee eee ee 7 condominium MOOG een ren nenne hea au bee tees Cao ng Sees 7 PIRAG MOOG ee a yr te aa se de ado aio dd aia e ee adds iw een 7 Pedestrian Keyswitch Optional 2 ccc eee eee eee ene 8 AR CHU hno Weviees 404 ca cirki rer e ade ee gs ee et era es oa 8 MIO MSI aaa en aa en ae pica Rad ee er 9 Automate COGNO sisse ee a a aces ae be en bone Ran ne 9 BUOLIOSE OVEINdE entre ene payee ner RE E er 10 Protection AA E ee rer ye tees seen ee utaaseeeed es 10 Gate Status INAICALON Eee ee ra a ee oe eet ee eee eee 11 Battery Low ProtectoNn sas cheep conn ae ee wee eee oi Re eee 11 Security Courtesy Light Timer 22 0 ne ee ei 12 Pre eSNG een ern were En Ss nee Lee 12 BOldSYy LOCK OUE seras nn ara rn HOUSE hy ene gen R
7. atically close Pedestrian Keyswitch The gate can be held open by keeping the key turned in the keyswitch As soon as the key is released back to its normal rest position the gate will close after the 5 second delay Ifa protection beam has been fitted refer section Protection Beam and the beam is broken while the gate is closing the gate will stop and re open to the pedestrian opening point The gate will remain in that position while the beam is broken and only close 5 seconds or whatever the pedestrian Autoclose time has been setto after the beam has been cleared The opening distance and the time that the gate remains open can be adjusted to suit Default values are described above Anti crushing Device The R3 and the R5 operator incorporates an electronic anti crushing mechanism that will sense if a person or vehicle has obstructed the gate If the anti crushing mechanism of a single or double gate system is activated while the gate s are opening the operator of the obstructed gate will stop The second gate in a double swing system will continue to open The stopped gate can be immediately operated using the remote control or gate release pushbutton provided that the obstruction has been removed The gate will close refer point regarding multiple collision below In the case where the gate s are closing both gates will re open if the anti crushing mechanism is activated regardless of which gate is obstructed As
8. c checklist for your gate automation system Should you experience a fault with the system see if the symptom corresponds to any given in the list below For each symptom listed the probable cause and action to be taken is given In the event of the symptom not being listed consult your installer for assistance A CAUTION PRIOR TO WORKING INSIDE THE CONTROL CARD ENCLOSURE ENSURE THAT THE MAINS SUPPLY TO THE SYSTEM HAS BEEN ISOLATED N NB As this product is used outside of the control of the manufacturer CENTURION SYSTEMS PTY LTD it cannot be held responsible for consequential damage as a result of the end user attempting to maintain the unitwithoutthe assistance ofa qualified installer SYMPTOM CAUSE ACTION e Gate does notopen orclose There is an object obstruct INDICATION STATUS LED fully or gate moves a short ing the movementofthe gate will be flashing four times per i 2 ds Anc ANG Sts e Anti crushing device setting iia is too sensitive Clear any obstructions from the gate Unhook the gate from the mechanical linkage and check that the motor operates correctly Consult your installer should there still be a problem e Position control system is Check that the sensor malfunctioning mounted adjacent the geared DC motor is clipped into position Check both MASTER and SLAVE motors where applicable e Battery voltage is low and the INDICATION STATUS LED battery protection is being will be flashing
9. d Page 10 Gate Status Indication optional feature The controller can provide visual indication inside the house of the position of the gate and the condition of the battery and power supply A LED is typically mounted on the intercom inside the house The different signals of the LED are described below LED STATUS INDICATION Slow regular flash Gate is opening Fastregularflash Gate is closing Off Gate is closed On Gate Is open 1 Flash 2 seconds Courtesy light latched on 2 Flashes 2 seconds Mains failure 3 Flashes 2 seconds Battery low 4 Flashes 2 seconds Collision shutdown Battery Low Protection The controller has circuitry that monitors the state ofthe battery During a power failure energy is drawn from the battery but notreplaced To protectthe battery from being quickly damaged the protection circuitry prevents the motors from being run offthe battery when the battery voltage drops below 10 6 volts iu I Status LED CHARGE LED s Tr rou rou LIGHT FUSE SET cg FUSE 16A 5 B En e3 eseseseees Per 8908989 QE pale cee cioeciocleg s ASTER BATT SS1 SS2 SS3 COM COM SOL 12V TRG IRB FRX LED PED LCK SET Status LED location on the CP75 Controller Card Indication that the battery low protection has been triggered is provided by the small gate status LED mounted on the intercom inside the house which will flash three times every two seconds The gate system is shutofffor atleast one minute
10. danger 10 Centurion Systems Pty Ltd does not accept any liability caused by improper use of the product or for use other than thatfor which the automated system was intended Principles of Operation The CENTSYS R3 and R5 rotary swing gate operators are both powered by a 12V DC motor using a maintenance free lead acid battery as the primary power source The battery is charged via a 220 240V mains supply ora solar panel The major benefit of this philosophy is uninterrupted operation of the gates even in the event of a mains power failure For light industrial applications the R3 and R5 operators are both available with a power pack which can deliver the full current draw of the 12V DC motor If battery back up is required a battery is fitted in a separate enclosure The capacity of the battery is determined according to the number of operations required in the eventofa power failure An independent motor drive unit operates each leaf of the gate Both single and double leaf systems are available The MASTER operator and the SLAVE operator where applicable consist of a high torque geared DC motor driving through a main reduction unit onto an output shaft The output shaft is linked to the gate via an articulated arm secured by a padlock The drive units are self locking preventing the gates from being forced open The electronic controller charger and maintenance free battery 7A H are housed inside the MASTER motor of the system only The e
11. he manual release mechanism How the obstruction detection and all othersafety features works All the safety considerations associated with operating an automated gate and that you understand the importance of explaining these safety instructions to all other users ofthe automated system Do notactivate your gate opener unless you can see itand can determine thatits area of travel is clear of people pets orotherobstructions NO ONE MAY CROSS THE PATH OF AMOVING GATE Always keep people and objects away from the gate and its area of travel NEVER LET CHILDREN OPERATE OR PLAY WITH THE GATE CONTROLS and do notallow children orpets near the gate area Page 4 4 Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched Secure all easily accessed gate opener controls in order to prevent unauthorized use of the gate 6 Keep the automated gate system properly maintained and ensure that all working areas are free of debris and other effects that could affect the gate operation and safety 7 Ona monthly basis check the obstruction detection system and safety devices for correctoperation 8 Allrepair and service work to this product mustbe done by a Suitably qualified person 9 This product was designed and built strictly for the use indicated in this documentation Any other use not expressly indicated here could compromise the good condition operation of the product an orbea source of
12. hen opening the gate until the gate stops This confirms that the Autoclose has been overridden On releasing the button the gate will continue to open fully and remain open indefinitely Closing the gate by using either the transmitter or intercom gate release button automatically resets the system back to Autoclose If the status LED refer to section GATE STATUS indication below is connected an additional confirma tion of the functioning of the override is provided while the button is held down The status LED will stop flashing and remain ON when the Autoclose has been overridden Protection Beam optional butrecommended An infrared beam or underground loop con ll nected to an inductive loop detector across the gate entrance may be connected to the controller N as an additional safety feature For optimum protection when using infrared beams two sets of beams should be used one on the hingeline ofthe gates and the second just outside the arc ofthe gate travel IT MT When a motor vehicle activates the loop or beam the following occurs e ifthe gate is closing itwillimmediately stop and re open e ifthe gate is open and the beam Is broken a trigger signal trying to close the gate will be ignored e If the AUTOCLOSE feature is selected the gate will remain open while the beam is broken or loop is activated Ifthe beam or loop is cleared the gate will only close again after the normal Autoclose time has expire
13. is pressed while the gate is moving the gate will automatically reverse direction This mode offers greater security than STANDARD mode as the gate can never be leftin a midway position CONDOMINIUM MODE The system can be set for CONDOMINIUM operation This facility is designed for greater safety and security in applications where there will be a number of users such as the entrance to a townhouse estate factory or office park In CONDOMINIUM Mode the gate is opened by pressing the pushbutton on the remote transmitter or intercom If the system is re triggered while the gate is opening the signal is ignored and the gate will continue to open The gate closes automatically as per the AUTOCLOSE facility described later in this user guide In CONDOMINIUM Mode the AUTOCLOSE cannot be overridden If the remote transmitter or intercom pushbutton is pressed while the gate is closing the gate will immediately reopen The gate cannotbe stopped in a midway position and will therefore always close Ifthe gate is triggered while the gate is in the open position the AUTOCLOSE timeris reset gt NOTE It is highly recommended that a protection beam be used in conjunction with this facility to preventthe AUTOCLOSE from closing the gate onto a vehicle passing through PIRAC PASSIVE INFRARED AUTOCLOSE This facility is an extension of the CONDOMINIUM facility described above Itis designed for applications Page 7 requiring greater security as the ga
14. ivating pedestrian facility is e faulty where applicable Check for corrosion of the wire terminations behind the keyswitch Consult your installer should the problem persist e Courtesy lightdoes notoper ate e Lightfuse blown Page 22 e Replace fuse 220V 3A fast blow Size 5x20mm CAUTION 220V make sure supply to system is isolated e Check that the lamp load does notexceed 500W e Check the bulb and replace if necessary Make sure that the bulb is making good electrical contact in its holder e Consult your installer should the problem persist Product Guarantee AllCENTSYS products are manufactured with extreme care thoroughly inspected and tested They are guaranteed for a period of 12 months provided that proof of purchase documentation is submitted with any claim The guarantee only covers repair components and labour provided that the equipment is returned to ourworkshop This warrantee will notapply to any equipment which A Has been subjectto misuse or which has been used for any purpose other than designed for by the Centurion Systems Pty Ltd B Has been repaired by any workshop and or person not previously authorised by Centurion Systems Pty Ltd C Has been repaired with components not previously tested passed or authorised by Centurion Systems Pty Ltd Page 23 CENTSYS 0 07 B 0001 R3 R5 User Guide 10 ul2012 www centsys com au
15. lectronic controller which co ordinates the operations of the drive units is further protected by a plastic enclosure inside the MASTER operator For added reliability the controller is fitted with advanced lightning protection based on circuitry designed and tested in conjunction with the CSIR The drive unit uses an innovative internal position control system with origin to track the movementofthe gate and accurately setthe open and close positions Each operator are fitted with an internal manual override release Page 5 Features amp Functions Introduction The R3 and R5 Rotary arm operators are fitted with the CP75 controller The controller synchronizes the functions ofthe gate operator Modes of Operation There are four different Modes of Operation that can be selected Only one mode can be selected at any onetime STANDARD with selectable Autoclose feature REVERSING with selectable Autoclose feature CONDOMINIUM compulsory Autoclose PIRAC compulsory Autoclose STANDARD MODE is the mostcommon The other modes are usually used for specialistapplications The Autoclose feature is described under the section Automatic Closing STANDARD MODE OF OPERATION The gates are opened in the following way gun Hand held transmitter sends coded signal Receiver uses signal to open or close the gate Radio Transmitter A hand held radio transmitter carried in the motor vehicle sends a coded
16. lights are fitted It is necessary to have at least a 35A h deep cycle low maintenance battery fitted in orderto provide sufficient back up capacity during days of poor weather Manual Release All gate operators have a means of manually operating the gate in the event of a total malfunction of the equipment If one is locked outside the property the padlocks connected to the clevis pin through the gate bracket can be unlocked This will allow the clevis pin to be removed and the linkage arm to swing away from the gate This will allow the gate to be opened sufficiently to allow a person to enter Once inside the property to release either operator complete the following procedure NB DO NOT OPEN THE COVERS WHEN EXPOSED TO DIRECT RAIN ALWAYS SHIELD THE UNIT WITH AN UMBRELLA es Clevis Pin Connecting Arm Unlock the padlock securing the connecting arm Swing the connecting arm to the side and open the Remove the clevis pin gate Page 13 To release the manual override proceed as follows Unlock and remove the operator cover Lift the controller housing fitted to a MASTER motor This is not necessary when releasing a SLAVE motor Setup Tool DO NOT USE Swing open the manual release dust cover Insert the allen key provided into the manual release mechanism and rotate it clockwise to release the gearbox approximately 12 turns Page 14 To re engage the drive disengage manual override Unscrew the allen
17. low the pillar courtesy lights to be switched from inside the house withouthaving to operate the gate The pushbutton switches low voltage and the spare Typical Security or Courtesy Light Installation pushbutton provided on many brands of intercom handsets can be conveniently used When the pushbutton is pressed momentarily the pillar lights will switch ON for the pillar time period and Switch off automatically If the pushbutton is pressed and held for approximately 4 seconds the pillar lights will stay on permanently The lights are switched off by simply pressing the pushbutton again Ifthe gate status indicator is fitted to the intercom handset it will flash once every two seconds to indicate that the pillar lights are ON permanently Low wattage 12V DC light fittings are also readily available and can be connected to the system drawing power directly from the battery Care must be taken to ensure that the power drawn from the system by lights and the motors does not exceed the re charge rate of the CP84ER5V01 battery charger A larger charger unitshould be fitted to cope with the additional load Pre Flashing For additional safety the courtesy lightcan be programmed to provide an early warning thatthe gates are aboutto operate When the gates are activated the lights will flash for 2 seconds before the gate starts to open or close The courtesy light timer will still function as normal only in certain modes the pre flash time is full
18. oes not operate and there is no reaction from the motor relays either Only the radio receiver relay clicks when the system is activated e An input is latching up the controller Page 20 Check that both the GREEN IRB infrared beam and LCK Holiday Lockout LEDs on the CP75controllerare ON e Check that the other RED SYMPTOM CAUSE ACTION input LED s are OFF They must only light up when the corresponding input is activated e Try operating the system using the TEST pushbutton onthe control card Consult your installer if the problem persists e Gate does notAutoclose e Infrared beam if fitted is Check that the GREEN LED faulty adjacentthe IRB inputis ON e When the IRB inputis ON e Then the infrared beam is clear Check that beam is correctly aligned Itshould be possible to hear the relay click as the beam is broken and cleared Ensure that nobody is e Check that the Autoclose mistakenly pressing and override facility is not being holding down the gate release pushbutton on either the remote or intercom for too long when activating the unit Refer to section Autoclose override operated e Gate starts closing butstops Intermittent operation of Check the GREEN IRB LED and re opens infrared beam iffitted on the controller It must remain ON if the beam is clear Consult your installer if the problem persists Unhook the gate from the mechanical linkage and check that
19. per the above when activating the system again both gates will close Page 8 o y e am pues N u HVAT ft m ai N UN Gates closing onto object Both gates automatically re open MULTIPLE COLLISION If the system is obstructed repeatedly four times after the initiation of an opening cycle and before the master motor gets back to its fully closed position the gate s will stop and remain locked in position for 1 minute After this time the gate can be restarted This function is a warning to the user thatthe obstruction mustbe removed The collision counter will reset to a count of zero when the master gate is fully closed The number of collisions that mustoccur before shutdown is activated is adjustable from 1 to 255 Automatic Closing The system has the facility to automatically close the gate after ithas been opened The time thatthe gate remains open is adjustable from 1 to 255 seconds The factory default is 15 seconds when the facility is Switched ON By defaultthe Autoclose function is off Page 9 AUTOCLOSE OVERRIDE INTERCOM PUSHBUTTON or REMOTE Press and hold the gate release for 3 seconds to override the Autoclose alal all un If the Autoclose function has been selected it can be conveniently and easily overridden for one cycle This override feature is activated by holding down the remote control push button or intercom gate release button approximately 3 seconds w
20. ply unit 120mA DC Current draw Max 15A Maximum solenoid lock current draw 2A Output shaft rotational speed 3 5 rpm Maximum output torque 140Nm Maximum number of operations per day Average 100 Maximum number of continuous operations 20 Typical time to open close a gate For standard pedestal in recommended position 10 seconds No of operations on a 7A H battery Should the mains power fail 20 Limit switches Sealed optical counter with origin switch Collision sensitivity Electronic adjustable Temperature range 20 to 50 C Housing protection IP55 Control card single or double motor CP75 Corrosion protection baseplate and arms Zinc electro galvanising Maximum gate length amp mass Max Allowable Leaf Mass 1000kg 550kg 350kg 250kg 180kg Max wind speeds for which the operator will open the gate For a 1 8m high gate 25 coverage 110km h 82km h 66km h 55km h 47km h Fora 1 8m high gate 100 coverage 55km h Alkm h 33km h 27km h 23km h Subject to system power supply Standard battery driven system with 7A H battery is limited to 20 operations per day For pedestal mount installations where the gate exceeds 3m and wall mount installations where the gate exceeds 2 5m itis recommended that an electric lock be fitted t This applies only to STANDARD pedestal mount installations installed according to the RECOMMENDED positions Page 18 Troubleshooting Guide This is a basi
21. te closes immediately behind the vehicle or person passing through PIRAC will operate only ifa protection beam or other type of vehicle detection system e g inductive loop has been fitted The remote transmitter or intercom pushbutton will only open the gate As a vehicle drives through the entrance it activates the protection beam and as soon as the vehicle clears the beam the gate will close immediately even before itis fully open If the gate reaches the fully open position without the beam being activated the gate will wait the AUTOCLOSE time and then re close If however a vehicle passes through the entrance activating the beam the gate will close the moment the vehicle has cleared the beam regardless of the AUTOCLOSE time Pedestrian Keyswitch Optional The pedestrian keyswitch is typically fitted to the gate pillar Its purpose is to open the gate a limited amountfor pedestrians In the case of a double leaf system only the MASTER gate will open e Fit key into keyswitch and turn key clockwise as though starting a motor car e Letthe key spring back to rest position and remove key immediately To allow time for removal of the key there is a 2 second delay before the gate begins to open Ifthe courtesy light refer section Security Courtesy light timer is connected to the control card it will flash twice indicating that the gate will open approximately 1 metre and then stop After5 seconds the gate will autom
22. the operator then drives fully closed Consult your installer if the problem persists e Anti crushing device is set too sensitively e Operator drives too far and Origin system notfunctioning Check that the origin sensor does not stop in the correct correctly which is mounted on the open and closed positions black plastic housing which covers the manual override is properly clipped in Page 21 SYMPTOM CAUSE ACTION e Origin position has been shifted e Consult your installer if the problem persists e Make sure that nobody has accidently used the origin adjustment tool to release the manual override Consult your installer should this be Suspected e Gate opens onits own e Permanent input on one of the trigger lines to the controller e Faulty triggerline cables Check that the RED LED s adjacent each trigger input on the controller TRG FRX PED are OFF and only Switch ON when that input is activated Consultyour installer e Radio transmitter has poor range e Transmitter battery flat e Radio receiver cannot receive transmitter signal properly Check that the fault only occurs with one of the transmitters Replace the battery Receiver mustbe mounted in an elevated position housed in a weatherproof non ferrous enclosure Make sure that the aerial is straight Consultyour installer e Master gate opens to pedes trian and closes e Keyswitch used for act
23. vice to our customers and support for our products A worldwide network of distributors and installers ensure that our products remain The Automatic Choice in access automation Further information is available on our website www centsys com au Centurion Systems Pty Ltd reserves the right to make changes to the products described in this document without notice and without obligation of Centurion Systems Pty Ltd to notify any persons of any such revisions or changes Additionally Centurion Systems Pty Ltd makes no representations or warranties with respect to this document No part of this document may be copied stored in a retrieval system or transmitted in any form or by any means electronic mechanical optical or photographic without the express prior written consent of Centurion Systems Pty Ltd Page 3 Introduction ACENTSYS GATE AUTOMATION system is a quality product designed to give many years of trouble free use provided itis correctly installed and maintained This guide highlights the features and operation of the CENTSYS R3 and R5 AUTOMATIC SWING GATE systems to ensure that YOU the user will getthe mostfrom your system Safety Instructions Even if you have used an automated gate before please read through the Safety Instructions carefully Make sure that you fully understand the following safety requirements before finally operating the automated gate Ensure that you fully understand How to operate t
24. y adjustable in 1 seconds increments The factory defaultis 2 seconds By default pre flashing is OFF Holiday lockout optional feature An ON OFF keyswitch or any other convenient apparatus such as a keypad or radio receiver can be connected to the gate system that will allow the system to be totally immobilised The keyswitch is mounted with access from the outside of the property When the keyswitch contact is OFF the gate Page 12 system will shut down and it will not be possible to operate the gate When the keyswitch is ON the gate system will operate normally This is an added security feature should the property be unattended for an extended length oftime Lightning Protection The CP75 controller has on board lightning protection The protection circuitry is based on a design developed in conjunction with the CSIR Itis however important to realise that the controller s protection only functions correctly ifan adequate lightning earth is fitted during installation Lightning damage is not covered under the normal guarantee of the equipment ALTERNATIVE POWER SUPPLY Solar Panel Optional With the battery driven system the battery may be charged using a solar panel in place of the conven tional charging circuit A 20 Watt panel will provide on average 10 12 daily operations of an average gate without causing the battery to discharge over a period of time The allowable number of operations will be reduced if 12V DC security
25. y eee En Ehe Ee 12 EIONENING PTOIEENON u wur ea iere he OF ese os ec earn widow era aoe Sew Ride nem BS 13 Alternative Power Supply vio eke cae eek eee ee Ree ee ka 13 SO Wy ONC yi ee A aye ey ee exe on See te eeee ee ee Gee ee eee eee ee 13 Manual Release sen ana eed ee oe rer ee 13 Basic MaIMeNANCe dsc ae es es pair Sees tee eens tee ee oa 16 ao A E EEE III 18 Troubleshopung GUIAS 2 sosiarrdd RA EH a era 19 PIOQUCLOUSTANIER ru teens Pek a Vias See Od BAe EI E ra eee re Nes 23 Page 2 Company Profile Centurion Systems Pty Ltd South Africa has been manufacturing automatic gate systems since 1986 and is committed to providing reliable cost effective solutions in the field of gate and access automation We offer a diverse range of products including gate motors GSM based products garage door motors remote controls keypads traffic barriers proximity access control and intercom systems Our products are developed by an in house team of talented engineers that are constantly researching new and innovative technologies to improve our existing products and expand our product range Our production facility in Johannesburg is ISO 9001 quality assurance certified and all our products are manufactured to the highest level of quality with a 100 test to specification Through a team of dedicated technicians and sales personnel together with a fully fledged in house training facility we are committed to providing unmatched ser