Icon 8 User Guide.pmd

image

Contents

1. Section List Important Information Control Panel Tvpe Securitv Companv Central Station Phone Date Installed Installed bv Emergency Numbers Local Police Fire Brigade Ambulance Doctor page 13 e Hap
2. starts and holds the sections that have been programmed for Exit or Entry delay disarmed This allows the user to exit the premises without activating the alarm When the system is armed and the Exit timer has finished Entry into the premises can be made via a section that has Entry delay This starts the Entrydelay and if the system is disarmed there will be no alarm This light is normally ON This indicates that the Plug Pack power and backup battery are normal When the Plug Pack power is not good i e the mains has failed the power light will single flash When the Plug Pack power and battery are not good the power light will double flash Flashing while in Program mode Program mode is entered when a user code is entered and isolate or test modes are selected Program mode is also selected when the master code is entered and the user codes are being viewed or changed When not in program mode the Program Light is Off page 3 Indicators cont d Partial Light On Light Fire Light Auxillary Light ON when the Partial mode has been selected and only some of the sections are armed Single flash when the system is Partially armed and Exit timer is running Double flash when the system is armed and the Entry timer is running The Entry timer is started when an Exit Entry is activated OFF indicates partial mode is not selected Off when the system is Off Single flash when the system is armed and Ex
3. system will not change to ON mode unless all section lights are out or isolated Power light should be ON and not flashing Program Fire and Auxillary lights if fitted should be out Exit Timer starts as soon as ON light starts flashing and beeper gives exit warning Exit via programmed Exit Entry sections only If the Exit Entry sections are not sealed by the time the exit timer expires then the siren and strobe will give 2 seconds warning and the entrv timer is started If the svstem is not turned to OFF mode before the entrv time expires a full siren strobe and alarm transmission to the Central Station occurs Example shows a User Code 1234 being used to change the system to ON mode Notes 1 Only part of the system will be armed Actual sections being armed depends on setup by technician during installation The section lights of the sections which are being armed in Partial mode must be out otherwise the system will not change to Partial ON mode Check Power light is on and not flashing Program Fire and Auxillary if fitted lights should be out Exit Timer starts as soon as Partial light starts flashing and beeper gives exit warning Exit via programmed Exit Entry sections only Ifthe Exit Entry sections are not sealed by the time the exit timer expires then the siren and strobe will give 2 seconds warning and the entry timer is started If the system is not turned to OFF mode before the entry time expires a
4. F mode Example shows a Master code eg 218572 used to Ban Enter your own Select User code 01 Select User code 07 0000 anne Off Exit program mode with the OFF key page 8 Changing Master Code Notes 1 Master code default is 218572 Master code is 6 digits long The Master code is only used to program the user codes It cannot change the status of the system The system must be in OFF mode to enter the master code Key Sequence Operation Enter existing Master 2 enter program mode amp Select function 00 GOBB B Code e 9 246812 Off Exit program mode with the OFF key Other Features The keypad panic may be initiated by holding both the ON and the OFF keys depressed together for a period of 3 seconds If the alarm aystem is monitored a duress report will be sent to the monitoring station and if enabled by the installer the si rens will sound Sirens enabled for Panic Keypad duress must be enabled by the installer at installation and is initiated by incrementing the last digit of a valid user code by 1 For example if the users code was 1234 then a duress signal would be sent to the monitoring station if the user entered 1235 as their code In all other respects the panel would react as if the normal code had been entered For user codes ending in 9 then a O would be entered eg normal code is 1949 duress code would be 1940 Keypad duress enabled Keypad D
5. ICON 8 User Guide Contents Contents Terms you may neeed to know Keypad Lights Keypad Buttons User Functions Fully Arming the System ON Mode Partially Arming the System Partial Mode___ Isolate a section from being Armed System OFF Disarming the System User Code Programming Master Code Programming Other Features Keypad panic Keypad Duress Test Functions Warranty Section List Important Information page 1 10 11 12 13 01 you may need to know Alarm state of a security system when an armed sensor has been activated Arming place a section or panel ready to accept an alarm Central A where alarms are received and appropriate action Station taken in response to the Station alarm Door A sensor which detects the opening of a door Contact EntryTimer A timer that is used to delay the activation of an alarm Exit Timer timer used to delay the arming of an Exit Entry section Handover A section that has Exit delay but only has Entry delay Section when an Exit and Entry Section has been activated first Isolate To inhibit or bypass one or more sections from arming Microwave A detector which detects movement by the use of microwave Detector energy Partial Only part of the security system is Armed Pre Programmed sections are isolated PIR Passive A detector which detects movement by sen
6. full siren strobe and alarm transmission to the Central Station occurs Example shows a User Code 1234 being used to change the system to Partial ON mode Isolate a Section from being Armed Notes When entering section numbers a two digit number eg 01 or a single 1 may be used Single digit entry i e the leading zero is ignored Only valid section numbers may be entered Sections are automatically de isolated when the system is changed to OFF mode Depending on technician setup isolations may be reported to the Central station Example shows a User Code 1234 being used to enter Isolation mode amp Sections 4 and 7 are being Isolated on or When desired sections are isolated Disarming the System OFF Mode Notes Only a valid User Code can change the system between OFF ON and Partial modes Fire Panic and Tamper inputs if fitted are always armed This key sequence also acknowledges or silences the siren strobe if a Fire Panic or tamper alarm is actuated Example shows a User Code 1 2 3 4 being used to change the system to OFF mode page 7 Changing User Notes User 01 default is 1111 User codes are 4 digits long User codes are used to change the status of the panel isolate sections or acknowledge alarms User codes cannot be the same or within one count of another User code including the first 4 digits of the Master Code To change User codes the system must be in the OF
7. it timer is running Double flash when the system is armed and the Entry timer is running The Entry timer is started when an Exit Entry is activated When the Fire input is triggered the Fire Light will start to Flash If after 30 seconds the alarm has not been ac knowledged by entering a valid user code and ON or OFF buttons then an alarm will be sent to the Central Station and the Fire Light will stay ON The Auxillary Light is used to indicate the state of the Panic and Tamper inputs When the Tamper input is activated the Auxillary Light will Single Flash When the Panic input is activated the Auxillary Light will Double Flash Not all panels have these indicators page 4 Keypad ROE 0 9 Keys Test Key Isolate Key Partial Key Off Key On Key Used to enter numeric Codes or Function Numbers Used when a valid User Code has been entered to enter Test mode Used when a valid User Code has been entered to Isolate a section usually before Arming the System Used when a valid User Code has been entered to Arm the System with Pre Programmed sections Isolated Used when a valid User Code has been entered to Disarm the System Used when a valid User Code has been entered to Arm the System it is also used as the code key when in programming mode NOTE Some keypads have a seperate code button to access program mode page 5 Fully Arming the System ON Mode Notes 1 The
8. ndicated by the date stamp and or serial number on the product Defective units returned by the buyer at his own expense during this period will be repaired or replaced at the option of the manufacturer with an equivalent piece of re manufactured and tested equipment The repaired or replaced equipment is then warranted for the balance of the initial warranty period or for thirty 30 days whichever is longer The repair or replacement will be without charge provided that the equipment has not been subjected to electrical of physical misuse or to unauthorised repair or modification The foregoing warranty is in lieu of all other warranties express or implied including but not limited to merchantability or fitness for a particular purpose The purchaser s exclusive remedy with respect to any and all losses or damages resulting from any cause whatsoever shall be repair or replacement as specified above Manufacturer shall in no event be liable for any consequential or incidental dam ages however occasioned whether by negligence or otherwise No suit or action shall be brought against manufacturer more than one 1 year after the accrual of the cause of action therefore No agent employee or representative of the Manufacturer nor any other person is authorised to modify this warranty in any respect This warranty gives you specific legal rights and you may also have other rights which vary from state to state
9. sing sudden Infra Red changes in Infra Red temperature e g Body Heat Plug Pack A transformer which converts the 240 VAC Mains Power to 16 VAC to run the Security System Sealed When section is Armed and has not been activated Silent A section may be programmed to be silent i e does not trigger the siren or strobe when alarmed Siren Timer timer used to limit the running time of the siren System OFF Security System is disarmed for all sections that are not programmed for 24 Hour Note Fire Panic and Tamper if available are still Armed System ON Security System is Armed for all sections that are not isolated page 2 Keypad Indicators Section Lights Power Light Program Light There are 8 or 24 section lights on the command centre When the system is in the OFF mode all non 24 hour sections are not armed and the Section Lights indicate the condition of the sensor When the Section Light is On the sensor is activated e g door contact detecting door open or motion detector sensing movement When the Section Light is OFF the sensor is not activated When the system is in the ON mode all non isolated sections are armed If the section light is FLASHING the sensor is activated and triggers the siren and strobe light if it is not silent This alarm is transmitted to the central station When the light is out the section is not activated When the system has been Armed an exit timer
10. uress page 9 Test Functions Notes Test your system regularly and this will keep you familiar with the system and confident in the system operation Maximum testing time is 10 minutes The system must be in OFF mode before entering test mode Test mode may not be entered until all alarm messages have been transmitted Some panels do not have all the test modes described below Test 1 Walk test Beeper operates and section light operates This test enables the user to walk around and activate sensors and check correct operation of sensors Siren test Siren sounds for 3 seconds Strobe test Strobe operates unitl next key press All lights and beeper operate until next key press used to check operation of lights and beeper Recall Last Alarm last alarm flashes until next key press Reset Smoke Detectors if fitted removes power from the smoke detectors for 5 seconds Start a Test Report on Dialler if fitted sends a test report to the Central station and synchronises the time for next test report Account number and phone number must be programmed for this test to start Example shows a User Code 1 2 3 4 being used to enter test mode Test 1 started walk test Test 2 started siren test Exit test mode page 10 Warranty Manufactured equipment is warranted to be free from defects in material and wokmanship for a period of 5 years 60 months from the date of manufacture as i

Download Pdf Manuals

image

Related Search

Related Contents

C30D6 - Dieselval  virtual panel, function generator, output data logger user manual for  Visitor Central Quick Sheet  Guide d`entretien et manuel d`installation  Creazione di un file di lavoro  Manual - TopsCCC  User`s Manual, PNC-2300A (English)  Hyundai D420ML  Mifare&I-CODE SLIカードカタログ [PDF: 676KB]  