1. Disassembly 1 Unhook the upper headgear straps from the frame There is no need to undo the fastening tabs 2 Remove the elbow from the mask by pressing the side buttons and pulling the elbow away Remove the elbow from the air tubing 3 While holding the bottom of the hook pull the corner of the frame slightly away from the side of the mask 4 Remove the frame from the rest of the mask Reassembly 1 Press the frame onto the rest of the mask ensuring it clicks into place at the top and at both bottom corners 2 Attach the top headgear straps to the frame by looping through each of the upper headgear hooks Ensure that the ResMed logo on the headgear is facing outward and right side up 3 Attach the elbow to the air tubing Attach the elbow and air tubing to the mask by pressing the side buttons and pushing the elbow into the mask Pull on the elbow to check that it sits securely in the mask Cleaning your mask in your home Your mask and headgear should only be handwashed by gently rubbing in warm approximately 30 C water using mild soap All components should be rinsed well with drinking quality water and allowed to air dry out of direct sunlight AN WARNING Always follow cleaning instructions and use mild soap Some cleaning products may damage the mask its parts and their function or leave harmful residual vapours that could be inhaled if not rinsed thoroughly AN CAUTION If any visible deterioration of a
2. for Her A Elbow 3 55 62762 1 Valve HI RAPS 2 Side buttons 231 BEH EA B Frame 238 222 62760 XS S 62761 M L 3 Lower headgear hooks KE 2440 4 THES OG 4 Upper headgear hooks EHERFF FARE C Cushion x3 amp amp amp 62736 XS 62731 S 62738 M 62739 L 5 Vent 38 TL BAL D Headgear A7 384 62757 S 62758 S 62756 Std 62759 Std 6 Lower headgear straps TH 3B 4340 4 FERRE OG 7 Upper headgear straps _E E2BaR a EF aba as A B C Frame system 128 Z amp JED AR A B C D Complete system Z RHA TRS EN XS Extra Small ZE 42 14 S Small Jr 1 M Medium P hay L Large AB x3 Std Standard EPE EE Quattro Air Quattro Air for Her 62752 XS 62753 S 62754 M 62755 L APAC APAC 62717 S 62772 XS 62718 M 62773 S 62719 L 62774 M ANZ ANZ 62725 S 62769 XS 62726 M 62770 S 62727 L 62771 M ResMed Quattro Air Quattro Air for Her 1 2 ResMed Ltd DISTRIBUTED BY 1 Elizabeth Macarthur Drive ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 RBB Bella Vista NSW 2153 USA EC REP ResMed UK Ltd 96 Jubilee Ave Milton Park Abingdon Australia Oxfordshire X14 4RW UK See www resmed com for other ResMed locations worldwide For patent information see www resmed com ip Quattro is a trademark of ResMed Ltd and is registered in U S Patent and Trademark Office 2014 ResMed Ltd 628088 2 2014 07 ResMe
3. ResMed Quattro Air Full face mask User guide English Fitting RATE AO Pd Z b 7 Removal INA FRE Reassembly 412838 TRATT ENGLISH Quattro Air Full face mask Thank you for choosing the Quattro Air This document provides the user instructions for the Quattro Air and Quattro Air for Her masks referred to collectively as Quattro Air throughout this manual Quattro Air has blue headgear while Quattro Air for Her has pink headgear Using this guide Please read the entire guide before use When following instructions refer to the images at the front and back of the guide Intended Use The Quattro Air is a noninvasive accessory used for channeling airflow with or without supplemental oxygen to a patient from a positive airway pressure PAP device such as a continuous positive airway pressure CPAP or bilevel system The Quattro Air is e to be used by patients weighing gt 30 kg for whom positive airway pressure therapy has been prescribed e intended for single patient reuse in the home environment and multipatient reuse in the hospital institutional environment N GENERAL WARNINGS e The mask must be used under qualified supervision for users who are unable to remove the mask by themselves The mask may not be suitable for those predisposed to aspiration e he elbow and valve assembly have specific safety functions The mask should not be wo
4. d com I IAT INI 628088
5. d representative Use a standard conical connector if pressure readings and or supplemental oxygen are required Fitting 1 Remove the elbow from the mask by pressing the side buttons and pulling the elbow away 2 With both lower headgear straps released hold the mask against your face and pull the headgear over your head Ensure that the label on the back of the headgear faces outwards when the headgear is put on 3 Undo the fastening tabs on the upper headgear straps Pull the straps evenly until the mask is stable and positioned as shown in the illustrations Reattach the fastening tabs 4 Bring the lower straps below your ears and loop the headgear into the lower hooks on the frame 5 Undo the fastening tabs on the lower headgear straps Pull the straps evenly until the mask sits firmly on the chin and reattach the fastening tabs 6 Connect the air tubing from your device to the elbow Attach the elbow to the mask by pressing the side buttons and pushing the elbow into the mask Turn on your device so that it is blowing air 7 Undo the fastening tabs on the upper headgear straps Readjust the straps evenly only enough that a seal is achieved and reattach the fastening tabs Overtightening may cause leaks 8 Your mask and headgear should be positioned as shown Removing your mask 1 Disconnect one or both of the lower headgear straps from the hook 2 Pull the mask away from your face and back over your head English 3
6. g size Talk to your clinician to have your face size checked against fitting template Note that sizing across different masks is not always the same English 5 Mask is too noisy Elbow incorrectly installed Remove the elbow from your mask then reassemble according to the instructions Vent is blocked or partially blocked Clean with a soft bristle brush until the vent is clear Mask leaks around the face Cushion membrane is creased or folded Refit your mask according to the instructions Ensure that you position the cushion correctly on your face before pulling headgear over your head Do not slide the mask down your face during fitting as this may lead to folding or curling of the cushion Mask could be the wrong size Talk to your clinician to have your face size checked against fitting template Note that sizing across different masks is not always the same Frame incorrectly fitted Remove the rest of the mask from the frame then reassemble according to the Instructions Technical specifications Pressure flow curve The mask contains passive venting to protect against rebreathing As a result of manufacturing variations the vent flow rate may vary 100 Pressure Fow cm H20 L min s 3 19 de 4 22 8 32 o 10 37 UN 12 41 16 48 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 20 94 Mask Pressure cm H O 24 60 28 66 30 69 32 72 36 77 40 82 Dead space information Therap
7. if available otherwise select FULL FACE as the mask option English 7 Notes e The mask system does not contain PVC DEHP or phthalates e This product is not made with natural rubber latex e The manufacturer reserves the right to change these specifications without notice Storage Ensure that the mask is thoroughly clean and dry before storing it for any length of time Store the mask in a dry place out of direct sunlight Disposal This mask does not contain any hazardous substances and may be disposed of with your normal household refuse Symbols CATALOG NUMBER oy 0 HUMIDITY LIMITATION tsrs us KEEP DRY AN AN Catalog number Humidity limitation Fragile handle with care Manufacturer Keep away from rain LOT BATCH CODE 60 C o 140F 20 4F TEMPERATURE LIMITATION Batch code Temperature limitation Not made with natural rubber latex European Authorized Representative This way up Indicates a Warning or Caution and alerts you to a possible injury or explains special measures for the safe and effective use of the device Caution consult accompanying documents Consumer Warranty ResMed acknowledges all consumer rights granted under the EU Directive 1999 44 EC and the respective national laws within the EU for products sold within the European Union English 9 Mask components TH SzRff rss 2814 Quattro Air Quattro Air
8. ing on the pressure settings patient breathing pattern mask point of application and leak rate This warning applies to most types of CPAP or bilevel devices The technical specifications of the mask are provided for your clinician to check that they are compatible with the CPAP or bilevel device If used outside specification or if used with incompatible devices the seal and comfort of the mask may not be effective optimum therapy may not be achieved and leak or variation in the rate of leak may affect the CPAP or bilevel device function Discontinue using this mask if you have ANY adverse reaction to the use of the mask and consult your physician or sleep therapist Using a mask may cause tooth gum or jaw soreness or aggravate an existing dental condition If symptoms occur consult your physician or dentist As with all masks some rebreathing may occur at low CPAP pressures Refer to your CPAP or bilevel device manual for details on settings and operational information Remove all packaging before using the mask Using your mask When using your mask with ResMed CPAP or bilevel devices that have mask setting options refer to the Technical specifications section in this user guide for mask selection options For a full list of compatible devices for this mask see the Mask Device Compatibility List on www resmed com on the Products page under Service amp Support lf you do not have internet access please contact your ResMe
9. rn if the valve is damaged as it will not be able to perform its safety function The elbow should be replaced if the valve is damaged distorted or torn e he vent holes must be kept clear e The mask should only be used with CPAP or bilevel devices recommended by a physician or respiratory therapist e The mask should not be used unless the device is turned on Once the mask is fitted ensure the device is blowing air English 1 Explanation CPAP and bilevel devices are intended to be used with special masks or connectors which have vent holes to allow continuous flow of air out of the mask When the device is turned on and functioning properly new air from the device flushes the exhaled air out through the mask holes When the device is turned off the mask valve opens to atmosphere allowing fresh air to be breathed However a higher level of exhaled air may be rebreathed when the device is off This applies to most full face masks for use with CPAP and bilevel devices Follow all precautions when using supplemental oxygen Oxygen flow must be turned off when the CPAP or bilevel device is not operating so that unused oxygen does not accumulate within the device enclosure and create a risk of fire Oxygen supports combustion Oxygen must not be used while smoking or in the presence of an open flame Only use oxygen in well ventilated rooms At a fixed rate of supplemental oxygen flow the inhaled oxygen concentration varies depend
10. system component is apparent cracking discoloration tears etc the component should be discarded and replaced Daily After each use Disassemble the mask components according to the disassembly instructions Thoroughly clean the separated mask components excluding headgear by gently rubbing in warm approximately 30 C water using mild soap To optimise the mask seal facial oils should be removed from the cushion after use Use a soft bristle brush to clean the vent Inspect each component and if required repeat washing until visually clean Rinse all components well with drinking quality water and allow to air dry out of direct sunlight When all components are dry reassemble according to the reassembly instructions Weekly Handwash the headgear Reprocessing the mask between patients This mask should be reprocessed when used between patients Cleaning disinfection and sterilisation instructions are available from the ResMed website www resmed com masks sterilization If you do not have internet access please contact your ResMed representative Troubleshooting Problem possible cause Solution Mask is uncomfortable Headgear straps are too tight The cushion membrane is designed to inflate against your face to provide a comfortable seal with low headgear tension Adjust straps evenly Ensure that the headgear straps are not too tight and that the cushion is not crushed or creased Mask could be the wron
11. y pressure Resistance with Anti Asphyxia Valve AAV closed to atmosphere Inspiratory and expiratory resistance with Anti Asphyxia Valve AAV open to atmosphere Environmental conditions Sound Anti Asphyxia Valve AAV open to atmosphere pressure Anti Asphyxia Valve AAV closed to atmosphere pressure Gross dimensions Mask fully assembled with elbow assembly no headgear Mask setting options Physical dead space is the empty volume of the mask to the end of the swivel Using the large cushions it is 222 mL 3 to 40 cm H20 Drop in pressure measured nominal at 50 L min 0 2 cm H20 at 100 L min 0 9 cm H20 Inspiration at 50 L min Expiration at 50 L min 0 6 cm H20 1 0 cm H20 Operating temperature 5 C to 40 C Operating humidity 15 to 95 non condensing Storage and transport temperature 20 C to 60 C Storage and transport humidity up to 95 non condensing DECLARED DUAL NUMBER NOISE EMISSION VALUES in accordance with ISO 4871 The A weighted sound power level of the mask is 28 dBA with uncertainty of 3 dBA The A weighted sound pressure level of the mask at a distance of 1 mis 20 dBA with uncertainty of 3 dBA 1 6 cm H20 lt 1 8 cm H20 Extra Small 150 mm H x 103 mm W x 106 mm D Small 152 mm H x 103 mm W x 107 mm D Medium 166 mm H x 103 mm W x 107 mm D Large 172 mm H x 103 mm W x 107 mm D For S9 Select Full Face For other devices Select MIR FULL

Download Pdf Manuals

image

Related Search

Related Contents

s。ftdrink ー  Fujitsu FI-6800 User's Manual  Analog Devices AD9843A User's Manual  www.philips.com/welcome  Guía de seguridad y certificaciones  Integrated Communications Module  Descargar - Notifier  NL-33 AUTO MAXI User manual  GE WASE4220 Washer/Dryer User Manual  SMARTEYE Sender/Receiver Reader User Manual  