Home
0.07.B.0011 D5-Evo D10 D10 Turbo User guide-5Jul2012-NG
Contents
1. be set to switch on at 20 00 in combination with Holiday un Feat Lockout Mode so your In iT hil functions driveway would be lit up and il al locked down to keep you safe at night wil FIGURE 33 e Time bar prevents something from switching on or being activated so use it to turn off functions like Courtesy Pillar Lights to save electricity during the day Or de activate the free exit loop at the exit to your premises after hours and over weekends FIGURE 34 Time bar can also be used to limit access For example your staff can get in on weekdays but will be locked out over the weekend or on public holidays for added security However there is only one group that can be set up per input So if you want your gardener s remote to be time barred for a certain period and your maid s to be barred for a different Time period you ll have to set the gardener s remote to open using one input like the operator and the maid s remote to trigger another input like the keyswitch e f your factory is particularly busy during certain hours of the day from Monday to Friday set your operator to keep the gates open during these times to allow for quick traffic flow During any other hour or over the weekend or public holidays you ll have to use your CENTSYS access control device keypad proximity reader etc to get in FIGURE 35 page 24 5 1 17 Battery Low Protection In the event of a po
2. CENTSYS Company overview Centurion Systems Pty Ltd South Africa has been manufacturing automatic gate systems since 1986 and is committed to providing reliable cost effective solutions in the field of gate and access automation We offer a diverse range of products including gate motors GSM based products garage door motors remote controls keypads traffic barriers proximity access control and intercom systems Our products are developed by an in house team of talented engineers that are constantly researching new and innovative technologies to improve our existing products and expand our product range Our production facility in Johannesburg is ISO 9001 quality assurance certified and all our products are manufactured to the highest level of quality with a 100 test to specification Through a team of dedicated technicians and sales personnel together with a fully fledged in house training facility we are committed to providing unmatched service to our customers and support for our products A worldwide network of distributors and installers ensure that our products remain The Automatic Choice in access automation Further information is available on our website www centsys com au Centurion Systems Pty Ltd reserves the right to make changes to the products described in this document without notice and without obligation of Centurion Systems Pty Ltd to notify any persons of any such revisions or changes Ad
3. g itt CW Emergency Stop will ry override normal FIGURE 21 Holiday Lockout Mode functions If somebody tries to operate the gate via a valid access control device such as a remote control etc with Emergency Stop the onboard buzzer will beep periodically for 30 seconds to confirm that the gate has been disabled using this feature The emergency stop is typically used at a manned entrance so that security is not compromised with a would be intruder possibly gaining access to the stop button In a domestic situation you can set up one of your remote pushbuttons to operate the emergency stop without compromising your security 5 1 8 Positive Close Mode Positive Close Mode is intended for applications where the gate must close fully against the gate end post for security reasons such as ensuring proper contact of the switch on the gate that feeds power to the electric fence This feature operates only during the last few millimetres when the gate closes It is recommended that a rubber strip be fixed to the front edge of the gate to cut down the noise when the gate closes against the end post 5 1 9 Operator Run Profiles The D5 Evo D10 and the D10 Turbo can be customised to your exact requirements using your LCD controller The open and closing speeds can be independently set Even the ramp up to full speed ramp down to close speed and crawl distance before the gate stops can be adjuste
4. the gate to where the operator is installed page 12 It is possible to adjust the delay before the gate opens in one second increments from zero to 65 seconds one minute and five seconds The default time is two seconds It is possible to adjust the width of the pedestrian opening from a minimum of 50 millimetres to the full gate opening in ten millimetre increments The default opening is one metre Features It is possible to adjust the delay before the gate closes in one f ang second increments from zero to 65 seconds one minute and une five seconds The default time is five seconds 5 1 5 Free exit Opening The Free exit Opening allows visitors to exit townhouses estates factories or office parks easily An inductive ground loop is mounted under the driveway inside the property a short deu distance away from the gate The output of the inductive ground Vehicle drives over loop detector is connected to the ibid Ye free exit input on the controller FIGURE 15 When a vehicle drives over the loop a detector senses the metal in the vehicle and activates the free exit function which opens the gate The ground loop cannot be activated by a person or any non metallic objects and can be set to only activate if it detects a large amount of metal Free exit inductive loop Free exit never initiates a closing f Free exit facilit cycle
5. 2A 12V charger Lockable Manual release access door Encoder sensor clips into support post page 4 FIGURE 1 Identification of parts 2 D10 D10 Turbo parts identification eS ee eee Refer to the drawings below for how to identify your D10 D10 Turbo operator and its parts 1 D10 D10 Turbo controller 2 Courtesy light fuse 3A F B 3 2x 12V 7 2Ah battery 4 Gate mounted origin marker 5 Origin marker bracket 6 Origin sensor clip under battery Lower cover Foundation plate Motor fuse 30A ATO 10 D10 D10 Turbo charger 11 Manual release handle 12 Lock cover 13 Encoder sensor clip behind charger 3 D5 Evo Manual override 3 1 Disengaging the Manual Override gearbox drive Carefully flip to the side the camlock cover and insert the key and rotate it 90 clockwise While holding onto the key pull open the access door to expose the manual override thumbwheel This will allow for the removal of the cover as well as for the rotation of the release thumbwheel Rotate the thumbwheel clockwise until gearbox releases and gate can be moved manually If the gearbox must be left in manual mode for an extended period of time for whatever reason it is recommended that the access door is locked This secures the cover and prevents access to the inside of the unit which could contain high voltages It also prevents the
6. 30 seconds company FIGURE 27 If the Ambush Alarm or Break In Alarm is utilised the system may be configured to operate one of the following outputs provided on the controller e Onboard buzzer emits a continuous tone Pillar Courtesy light contact Safety beam common Status LED output Auxiliary 1O which can be used to connect to a third party alarm and security company or a CENTSYS G SWITCH 22 device to alert you of the alarm via SMS It is typical to select only one of the alarm features Requires infrared gate safety beams to be installed page 19 features and functions 5 1 13 External Gate Status Indication A LED Light Emitting Diode mounted on your intercom allows you to view the position of your gate and the condition of the battery and power supply from the safety of your home The different signals of the LED are described below FIGURE 28 Off Gate is closed On Gate is partially or fully open Continuous slow flash Gate is opening Continuous fast flash Gate is closing One flash every two seconds Courtesy Pillar lights on Two flashes every two seconds No mains present Three flashes every two seconds Battery voltage is low Four flashes every two seconds Multiple collisions have occurred If you choose not to fit a Gate Status Indicator the Status LED on the controller can also be used for trouble shooting 5 1 14 Courtesy Pillar Light Timer optional feature Courtesy P
7. D10 and D10 Turbo and other CENTSYS operators that are equipped with an onboard receiver are able to recognise the shift button signals Using a shift button also prevents you from enabling functions like Holiday Lockout Mode by accident because you have to use both hands to press the two button combination page 22 Another function provided with this receiver is the ability to record the memory location of each remote control mapping this to the name of the owner of the remote if recorded This allows any transmitter that is lost or stolen to be selectively erased from the system without affecting any of the other remotes installed It is also possible to erase the functions of certain buttons on a remote control if they re no longer required Alternatively the functionality of Features certain buttons can be changed to trigger different functions and functions At any stage remote controls can be selectively added deleted or edited within the system Contact your gate automation specialist or Centurion Systems Pty Ltd for assistance 5 1 16 ChronoGuard Timer a world first ChronoGuard a world first is a powerful multichannel timer feature which has been added to the D5 Evo D10 and D10 Turbo controllers A Real Time Clock and Calendar RTC lets you set the following features to operate automatically or be prevented from operating time barred during any Time period you choose Trigger TRG auto a
8. a continuous tone until the safety beams have been cleared Battery low Buzzer will emit three beeps every two seconds for 30 seconds Refer to section Battery Low Multiple collision Buzzer will beep periodically until condition is cleared Refer to section Anti crushing collision count Holiday lockout If the Holiday Lockout has been enabled when triggering to operate the gate the gate will not operate but the buzzer will emit one beep periodically for 30 seconds Emergency stop If the Emergency stop button has been activated the buzzer will emit buzzer will emit one beep periodically for 30 seconds Time barring if a time barred input or remote control is operated Diagnostics during a time barring period in addition to the gate not reacting to the input being activated or the remote control the buzzer will emit one beep periodically for 30 seconds Mains failure If the mains supply to the charger has failed the buzzer will emit two beeps every two seconds for 30 seconds Safety beam broken if something in the path of the beams the buzzer will emit one beep periodically for 30 seconds Safety beam failure if the safety beams are not operating the buzzer will emit five beeps periodically for 30 seconds beams test circuit must be enabled Contact your gate automation specialist or Centurion Systems Pty Ltd for further assistance WARNI NG Do not attempt to repair the unit yourself Any work performed by una
9. damage injury cost or expense suffered by persons and or to property which either directly or indirectly arise out of any one of the following occurrences a Failure to install the product in accordance with the installation instructions provided by Centurion Systems Pty Ltd b Failure to abide by the safety instructions provided by Centurion Systems Pty Ltd This warranty will not apply to any equipment which 24 month a Has not been installed in accordance with the installation product instructions provided warranty b Has been subject to misuse or which has been used for any purpose other than that designed for by the manufacturers c Has damage caused as a result of handling during transit atmospheric conditions including lightning insect infestation power surges or other forces outside of the control of Centurion Systems Pty Ltd d Has been repaired by any workshop and or person NOT previously authorised by Centurion Systems Pty Ltd e Has been repaired with components not previously tested passed or authorised by Centurion Systems Pty Ltd page 31 PTI Optional extras SSS CENTSYS infrared Safety Beams Always recommended on any gate automation installation SMARTGUARD keypad CENTSYS Cost effective and versatile infrared keypad allowing for access to safety beams pedestrians armed response companies etc _ 4 SMARTGUARD SOLO Lattice Proximity keypad Acce
10. 0 Turbo Maximum Operating Speed for Corresponding Gate Mass Table page 30 PTO 24 Month product warranty en You can register your product s online at www centsys com au which will assist you in keeping a record of your date of purchase or installation serial numbers etc This information may come in handy for future reference to help you in the event of a warranty claim or to remember your installer s details or for any other future reference needs that may arise All CENTSYS products are manufactured with extreme care thoroughly inspected and tested All CENTSYS products are warranted against faulty materials and workmanship for a period of 24 months from the invoice date of the product or 26 months from the manufacturing date as shown on the serial number label of the operator whichever expires first The warranty will cover the repair or replacement at the discretion of Centurion Systems Pty Ltd of such faulty materials or parts free of charge provided that the equipment is returned to our workshop The workmanship of the installation of the products carried out by any third party is specifically not covered under this warranty please consult with your installer about their workmanship warranty terms and conditions For equipment not of CENTSYS manufacture the warranty as supplied by the original manufacturer will apply No claims whatsoever will be recognised under the terms of this warranty which pertain to
11. Beam Autoclose page 14 can be used with Reversing Mode An infrared Safety beam needs to be installed across the gate entrance and connected to the Closing Safety Beam input on the D5 Evo or D10 D10 Turbo to use this function in order to prevent the gate from closing on people pets or vehicles Page 18 e 5 1 2 3 Condominium Mode This mode is ideal for increased safety and security in multi user applications such as townhouses estates factories or office parks If you select Condominium Mode your gate will open when pressing the button of the remote control or the gate door release pushbutton on the intercom but pressing the button again while gate is opening will be ignored It will not cause the gate to stop or to reverse Only the internal Autoclose described on page 11 of this User Guide which is automatically enabled will close the gate If the button of the remote control or intercom gate release is pressed while the gate is closing the gate will immediately reopen The gate cannot be stopped in a midway position and will therefore always close If the button is pressed while the gate is in the open position the Autoclose timer Page 11 is reset Finally the Autoclose Override feature described on page 11 cannot be applied in this mode page 9 We highly recommend that you use protection beams if you select Condominium Mode in order to prevent the gate from closing on people pets or vehicles Fea
12. Standard Mode is the most commonly used mode for domestic applications as it allows full control of the gate Press the button of the remote control or the gate door release pushbutton on the intercom for approximately one second to get the gate in motion FIGURE 11 page 8 If you press the button again while the gate is moving the gate will stop Press the button for a third time and the gate will go into reverse Autoclose page 11 and PIRAC Beam Autoclose page 14 can be used with Standard Mode An infrared Safety beam needs to be installed across the gate A entrance and connected to the Closing Safety Beam input Features on the D5 Evo or D10 D10 Turbo to use this function fur ieee in order to prevent the gate from closing on people pets or vehicles Page 18 e 5 1 2 2 Reversing Mode Reversing Mode offers slightly more security than Standard Mode as it allows you to close your gate quickly by pressing for instance your remote control just as you drive through the gate to prevent children or pets running out or anybody getting in behind you When pressing the button of the remote control or the gate door release pushbutton on the intercom your gate will be set in motion If you press the button again the gate will move in the opposite direction So if the gate is opening and you press the button the gate will stop and immediately start to close and vice versa Autoclose page 11 and PIRAC
13. am is cleared and the gate will then stop and close If the gate has reached its fully open position it would stop and remain open until the beam is cleared PIRAC mode s stop on opening configuration will open the gate a short adjustable distance past the point at which the beam was broken and stop wait for the beam to be re made or the Autoclose timer to expire then close page 14 This mode can only be used if a Closing Safety Beam FIGURE 17 FIGURE 18 closing q FI GURE 19 e 5 1 6 1 PIRAC Override The PIRAC Beam Autoclose Mode can be overridden in Standard and Reversing Modes Similar to overriding the Autoclose function you must press and hold the button of the remote control or intercom gate release for at least 6 seconds The gate response will be to start opening and then to stop for a pause time of three seconds and then continue to open as soon as the PIRAC Override Feat feature is activated Once the gate resumes opening you may un release the remote control button or intercom gate release and the gate will continue to the fully open position with PIRAC Mode overridden Your gate will stay open until you use the remote control or intercom gate release to close the gate The D5 Evo D10 and the D10 Turbo will then revert to normal PIRAC operation 5 1 7 Holiday Lockout Mode This feature completely immobilises the operator and deactivates all inputs so nobody can get into
14. ction system and safety devices for correct operation are in working order once a month Children should be supervised to ensure that they do not play with the appliance This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Always be mindful of where your limbs are when dealing with moving parts you don t want your fingers to be pinched or worse Keep your gate controls remote controls in a safe place You don t want anyone getting in uninvited Look after your gate and it will look after you Ensure that all working areas are debris free and that your automated system is well maintained and your CENTSYS operator should last you a very long time Ensure that any technician that works on your operator has been trained by CENTSYS This product was designed and built strictly for the use indicated in this documentation Any other use not expressly indicated here could compromise the good condition operation of the product and or be a source of danger Centurion Systems Pty Ltd does not accept any liability caused by improper use of the product or for use other than that for which the automated system was intended page 1 Iintroduction This User Guide contains all the infor
15. ctivation and time bar Free exit FRX auto activation and time bar Pedestrian opening PED auto activation and time baf Holiday Lockout LCK auto activation and time bar Closing Beam IRBC auto activation only Courtesy Pillar Light control AUX auto activation and time bar Courtesy Pillar Light relay time bar only Auxiliary output auto activation and time bar It is possible to time bar the operation of the device physically wired to this feature and or the same feature controlled via the radio receiver Spare output which via a relay board can drive a variety of external devices such as sprinkler system fountain etc A Time period can be a once off event or can be set to repeat on a weekly or annual basis The weekly repeat can be chosen to occur on every day of the week weekdays only weekends only or any specific day The minimum duration of a Time period is one minute and you can set 100 different Time periods The Tp icon will appear on the display to indicate that a Time period is active You can even set up different conditions by combining Time periods as well as set up exclusions once off Time periods when the auto activation or time bar period must be ignored so your gate will automatically open at certain times on weekdays but will know not to open on a public holiday page 23 e 5 1 16 1 Some examples of how to use ChronoGuard e Pillar Courtesy Lights could
16. d Please contact Centurion Systems Pty Ltd for more information on finding the configuration that is best for you page 16 5 1 10 Anti crushing Sensitivity The D5 Evo D10 and the D10 Turbo incorporate a sensitive electronic anti crushing technology that activates if a person or vehicle obstructs your gate The operator will respond differently to obstructions depending on the Operating Standard e g CE UL325 you select The typical response for an opening gate is to immediately stop and a closing gate will stop then immediately reopen Collision force can be set independently per direction of travel and can be set from minimum to maximum in five incremental steps A sixth incremental step will disable collision sensing entirely and allow for maximum force the motor will run until it stalls at which point a collision will be detected i Ca Gate closes hits obstruction stops and closes immediately i E Gate opens hits obstruction and stop FI GURE 23 Step six should only be used if additional safety measures such as infrared beams and sensitive edges are present e 5 1 10 1 Collision Count A counter monitors the number of collisions the gate experiences before it fully closes If the number exceeds the default value of four which can be adjusted in the Multiple Collisions Counter the controller will shut down The Status LED page 20 will flash four times every second until a
17. d mounted adjacent the gate entrance to operate this function There is a default but adjustable two second delay before the gate FIGURE 13 opens to warn the pedestrian that the gate is about to move as well as give the person enough time to move their hand away if they are reaching through the gate to operate a keyswitch or a keypad If the Courtesy Light Page 20 is connected to the control card it will flash indicating that the gate will open a default distance of approximately one metre adjustable The gate will close after a default time of five seconds adjustable FIGURE 14 The gate can be kept open by keeping a trigger on the input keeping your key in the keyswitch for example once removed the gate will close after the default but adjustable five seconds The Pedestrian Opening Input is fully configurable and can be set to suit your needs You can adjust the pre opening time delay the amount that the gate opens and the pedestrian Autoclose delay using your LCD controller Refer to the notes below If a Protection Beam page 18 is fitted and the beam is broken while the gate is closing the gate will stop and open to the pedestrian position The gate will remain open while the beam is broken and the 5 second adjustable Autoclose delay will only commence once the beam has been cleared For safety reasons it is recommended that all pedestrian keyswitches and keypads are installed on the opposite end of
18. ditionally Centurion Systems Pty Ltd makes no representations or warranties with respect to this document No part of this document may be copied stored in a retrieval system or transmitted in any form or by any means electronic mechanical optical or photographic without the express prior written consent of Centurion Systems Pty Ltd Contents IMPORTANT SAFETY FEATURES Introduction D5 Evo overview D10 overview D10 Turbo overview D5 Evo parts identification D10 and D10 Turbo parts identification D5 Evo manual Override Disengage the gearbox drive Re engage the gearbox drive D10 and D10 Turbo manual override Disengage the gearbox drive Manual release latching Features and functions Introduction Gate Operation 5 1 1 Full Gate Opening 5 142 Modes of Operation SLL Standard Mode 5 1 2 2 Reversing Mode 5 2 3 Condominium Mode 5 1 2 4 PLC Mode 3 1 Deadman Mode 5 1 3 Automatic Closing Autoclose Mode 5 1 3 1 Autoclose Override 3 1 3 2 Autoclose Advanced Option 5 1 4 Pedestrian Opening 5 1 5 Free exit Opening 5 1 6 PIRAC Mode Beam Autoclose optional 5 1 6 1 PIRAC Override 5 1 7 Holiday Lockout Mode 5 1 6 1 Emergency stop 5 1 8 Positive Close Mode 5 1 9 Operator Run Profiles 5 1 10 Anti crushing Sensitivity 5 1 10 1 Collision Count page 1 page 2 page 2 page 3 page 4 page 5 page 6 page 6 page 6 page 7 page 7 page 7 page 8 page 8 page 8 page 8 page 8 page 8 pag
19. dware kit through the hole in the gearbox as indicated e Make sure the split pin goes allthe way through as shown e Raise the handle and lock e Remove the key and fold back the lock cover page 7 FIGURE 5 FIGURE 8 FIGURE 9 Manual Override Features and functions 5 Features and functions u J Introduction The D5 Evo and D10 D10 Turbo sliding gate operators advanced functions are controlled by intelligent micro controller based electronic controllers An intuitive LCD Liquid Crystal Display controller with a user friendly menu allows for quick and easy set up and the ability to change functions at the touch of a button and displays useful diagnostics 5 1 Gate operation 5 1 1 Full Gate Opening The CENTSYS remote controls that operate with the onboard receivers of the D5 Evo D10 and D10 Turbo Sliding gate operators are used to operate the gate However most automatic gate installations are also fitted with an intercom which provides for communication between the house building and the gate The handset is usually fitted with a gate door release pushbutton which when pressed will operate the gate 5 1 2 Modes of Operation To operate the gate to open fully the D5 Evo D10 and D10 Turbo ave a number of operating modes to choose from depending on the application Only one mode can be selected at any given time e 5 1 2 1 Standard Mode
20. e 9 page 9 page 10 page 10 page 11 page 11 page 12 page 12 page 13 page 14 page 15 page 15 page 16 page 16 page 16 page 17 page 17 6 1 6 2 9 This icon indicates tips and N other information that could be A 5 1 11 Safety beams optional but recommended feature 5 1 11 1 Closing Safety Beams 5 1 11 2 Opening Safety Beams 5 1 12 Intruder detection Alarm a world first 5 1 12 1 Ambush Alarm SL 122 Break in Alarm 5 1 13 External Gate Status Indication LED 5 1 14 Courtesy Pillar Light Timer optional feature 5 1 14 1 Courtesy Pillar Light Control 5 1 14 2 Courtesy Pillar Light act as Warning Light 5 1 14 3 Pre open and pre close delay 5 1 15 Onboard Multichannel Receiver 5 1 16 ChronoGuard Timer a world first 5 1 16 1 5 1 17 Battery Low Protection Additional features Battery saver Solar power supply 6 2 1 D5 Evo 6 2 2 D10 and D10 Turbo Lightning protection Some examples of how to use ChronoGuard Basic Maintenance Diagnostics Specifications 24 Month product warranty Optional extras useful during the installation page 18 page 18 page 18 page 19 page 19 page 19 page 20 page 20 page 21 page 21 page 21 page 22 page 23 page 24 page 25 page 26 page 26 page 26 page 26 page 26 page 27 page 28 page 29 page 30 page 31 page 33 This icon denotes variations and other aspects that should be considered during installation This icon indicat
21. e is opening it will stop then close If the gate is closing it will continue to close Please contact Centurion Gate closed gate cannot open Systems Pty Ltd for more Gate opening gate stops and re closes information on suitable Gate closing gate continues closing protection devices FIGURE 25 page 18 5 1 12 Intruder Detection Alarms a world first e 5 1 12 1 Ambush Alarm Once activated if the opening or closing beams are continuously interrupted for a predefined time the Ambush Alarm will sound Features Intruders often cover beams and functions lenses thus breaking the beam so your gate stays open after you have entered or left your property but with the Ambush Alarm enabled you can be instantly alerted of any criminal os Intruder masks safety beams activity 30 seconds later alarm is activated e 5 1 12 2 Break In Alarm FIGURE 26 If the closing beam on the outside of your property is broken the Break In Alarm will sound and continue until 30 seconds have passed since the beam Is re made Intruders will not be able to loiter outside your property as the Break In Alarm will immediately alert you of their presence and the noise of the onboard buzzer is often an effective deterrent Optionally the Intruder breaks safety beam alarm signal can be routed while loitering at gate alarm immediately activated for to an armed response
22. ers are supplied standard with a multichannel receiver compatible with CENTSYS Features secure code hopping remote and controls The receiver will allow functions any combination of the different inputs such as Trigger Pedestrian Holiday Lockout etc to be operated from a single multi button remote control You can artificially increase the number of buttons of a CENTSYS multi button remote control by using a two button Sey combination One of the buttons is used as a Shift button to allow the other buttons to be used again in combination with this button Press and hold the shift button and then press one of the other buttons to create a new button The shift button cannot be used as a button on its own it must always be used in combination with another button Use of the shift key principle allows a three button FIGURE 31 i I Press and transmitter to gain an extra hold the A fourth button button and operate four ev as a shift key functions and a four button z geia an transmitter gains two extra B o operate buttons and can operate six 4 50r6 functions FI GURE 32 This is quite handy if you d like to control additional devices from a single multi button remote control for example your garage doors if they are equipped with CENTSYS code hopping receivers However it s also important to note that other devices cannot be activated with the new shift button only the D5 Evo
23. es warning caution or attention Please take special note of critical aspects that MUST be adhered to in order to prevent injury IMPORTANT Safety instructions Even if you have owned and used an automated gate before we suggest that you read through the safety instructions below very carefully Although years of thought have been put into every CENTSYS product and your safety is our top priority accidents do happen So please make sure that you fully understand the following safety requirements before using your automated gate Before you attempt to use your new gate operator for the first time you should know How to operate the Manual Release thumbwheel How the Obstruction Detection System and all other safety features work All the safety considerations that come with operating an automated gate and the importance of explaining these considerations to everyone who uses the operator DOs and DON Ts L 10 11 Do not activate your gate opener unless you can see it Make sure that no people pets or any other obstructions are in your gate s area of travel NO ONE MAY CROSS THE PATH OF A MOVING GATE Our advanced obstruction detection technology is designed to stop your gate in its tracks should a child or pet be in the way However this is a reactive system and should never supersede proactive measures of preventing people pets or vehicles from moving into the path of a moving gate Check if the obstruction dete
24. ft of any components and provides full protection from the elements FIGURE 3 Do not remove the thumbwheel Removal of the thumbwheel may result in water entering the gearbox and the warranty will be void 3 2 Re engaging gearbox drive Rotate thumbwheel anti clockwise until thumbwheel feels loose in the hand Make sure that the manual override access door can be closed Slide gate until gearbox drive engages Never run the motor before the unit is engaged FIGURE 4 page 6 4 D10 D10 Turbo Manual override a ee Tu BE IE BER A Be 4 1 Disengaging the gearbox drive Flip down the lock cover and Insert the camlock key and rotate it 90 clockwise Pull down the manual release handle to override the gearbox and allow it to be moved manually Reverse the process to re engage the gearbox drive 4 2 Manual release latching If the gearbox must be left in manual mode for an extended period of time for whatever reason it is recommended that the manual release is latched the handle raised back into its normal position and locked locking the cover in place at the Same time This prevents access to the inside of the unit which contains high voltages and prevents theft of any components and provides full protection from the elements With the manual release handle pulled down follow the process below to latch the manual release e Insert the split pin Supplied with the mounting har
25. he facility to automatically close the gate after it has opened When enabling this feature the time that the gate stays open is by default fifteen seconds this time is adjustable As described in the previous section Autoclose is selectable with Features Standard and Reversing Modes page 9 and by default the function is and off However Autoclose is automatically enabled in Condominium Mode functions We highly recommended that a safety beam is installed across the gate entrance and connected to the Closing Safety Beam input on the D5 Evo the D10 and the D10 Turbo if you enable Autoclose Mode in order to prevent the gate from closing on people pets or vehicles It is possible to adjust the delay before the gate closes in one second increments from zero seconds to four minutes The default time is five seconds e 5 1 3 1 Autoclose Override Automatic closing can be overridden in Standard and Reversing Modes by pressing and holding the button of the remote control or intercom gate release for no less than three brecs and hoidremote seconds The gate response will control pushbutton be to start opening and then to PALAA IAE E ED stop as soon as the Autoclose Override feature is activated On releasing the button the gate will continue opening until fully open Your gate will stay open until Gate stops to i
26. illar Lights can be connected through the controller if a 220 240V power supply is available at the gate The lights will switch on every time the gate is given a signal to operate and stay on for an adjustable period of one second to ten minutes in increments of one second then automatically turn off FIGURE 29 The purpose is to bathe your entrance with light when you open the gates and increase your security as you drive into your property it also saves electricity as the lights only come on when you use the gate motor Using the Pedestrian Opening feature will cause the Courtesy Pillar Lights to flash three times before the gate opens page 20 e 5 1 14 1 Courtesy Pillar Light Control The Courtesy Pillar Lights can be switched on from inside your home or office by connecting a pushbutton to the D5 Evo D10 or D10 Turbo controller For your safety this pushbutton switches only low voltage signals Press and release the button for the lights to switch on for the defined period then switch off automatically Press and hold the button for three to four seconds for the lights to stay on permanently until you push the button again If the Gate Status Indicator is fitted to the intercom handset the LED will flash once every two seconds to indicate that the lights are on permanently This feature can also be operated using your remote control Simply set one of the spare buttons on the transmitter to switch your Cour
27. ly copper based grease as necessary Charger The D5 Evo D10 and D10 Turbo operators have chargers separate to the main controller In the case of product malfunction the charger fuse Should be checked but only by a qualified electrician Always isolate the mains supply to the operator before attempting to remove and check the fuse Check the Mains Present icon on the main diagnostic screen or switch to the battery charger diagnostic screen and check the charger voltage right hand value This should indicate 13 8V for the D5 Evo and 27 6V for the D10 and D10 Turbo Each charger has a red light LED to indicate mains supply Gearbox Oil Level Gearbox Oil Level Check the oil level as described in the Lubrication section of the Installation Manual Should the installation manual be unavailable please refer to the online manuals on our website www centsys co za Alternatively please contact your Centurion Systems Pty Ltd installer for assistance page 28 r8 Diagnostics Depending on the type of fault or condition of the motor audible feedback will be given via the onboard buzzer Listen out for this and refer to the table below The different conditions are given in order of precedence Break in alarm if the safety beams have been broken with this feature set the buzzer will emit a continuous tone for 30 seconds Ambush alarm if the safety beams have been broken with this feature set the buzzer will emit
28. mation you need to configure and operate your new D5 Evo D10 or D10 Turbo Sliding Gate Operator From safety instructions to basic principles of operation and an in depth description of your CENTSYS product s many features and functions By the time you have finished reading this guide you will have learnt how to make the most out of your gate operator Even basic maintenance is covered but in the unlikely event that your CENTSYS product malfunctions rather leave it to the professionals and contact your installer or nearest CENTSYS outlet contact details listed on the back page for prompt assistance DS5 Evo overview The D5 Evo is driven by a high torque 12V DC motor which can effortlessly shift gates weighing up to 500kg perfect for domestic and light industrial use The gearbox moulded from a high tech engineering polymer not only looks good but is corrosion free and guarantees that even if you live on the coast your D5 Evo will just keep on going For your security the internal gearset has a self locking action so forced entry is no longer an option for would be burglars An optional theft resistant cage makes intruders lives even more difficult For your Safety our revolutionary limit switch mechanism monitors the speed and location of your gate for accurate position control and sensitive anti crushing protection The D5 Evo is packed with features and functions all easily accessible from a user friendly LCD controller M
29. ndicate you use the remote control or a eee ne ae intercom gate release to close has been engaged the gate The D5 Evo the D10 and the D10 Turbo will then revert to normal Autoclose operation The Autoclose function cannot be overridden in Condominium Release pushbutton gate will continue to open Mode fully and stay open It is possible to adjust the override time or the override time or hold down the button in order to override Aautoclose in one second increments from one to ten seconds The default time is three seconds FIGURE 12 page 11 e 5 1 3 2 Autoclose advanced options You can also independently set Autoclose to function when the gate Is partly open fully open or partly closed For example disable Autoclose when the gate is partly closed to allow construction workers gardeners etc access to your property although this comes with security risks By enabling the Autoclose in all states of Features gate movement ensures that the gate can never be left in any position and other than fully closed The default setting when enabling Advanced functions Autoclose is partly open and fully open but not partly closed 5 1 4 Pedestrian Opening The Pedestrian Opening input opens the gate just wide enough for a pedestrian to pass through the opening A second button on your remote control can be used to operate the Pedestrian Opening function You can also seta keyswitch or keypa
30. owever there are some basic checks that should be carried out regularly every six months These checks will increase the long term reliability of the system and prevent erratic operation of your gate WARNING Isolate mains supply as well as disconnect the battery before cleaning or working on the equipment General e Keep the track clear of stones dirt and obstructions e Ensure that all rollers run freely e Put the operator into Manual Mode and check that the gate runs freely on its rail and does not catch or foul against the walls or pillars e Ensure that the gate wheels and guide rollers are rotating freely and are not worn In high volume applications it will be necessary to replace these components regularly e Ensure that the rack is properly secured to the gate and that it does not press down onto the operator pinion at any point along its travel e Keep shrubs and vegetation clear of the motor and rack e Check that the key still operates the camlock spray with lubrication if necessary e Keep the inside of the motor housing clear of insects and dust Battery CENTSYS operators which are fitted with maintenance free lead acid batteries should provide at least three years of normal service life For sites utilising an external large capacity 35Ah low maintenance battery ensure that the level of liquid electrolyte level is correct In all instances check for corrosion of the battery terminals Clean and app
31. r charge the battery instead of the FR conventional charging circuit A 20 Watt panel will provide enough power for 20 operations less if 12V DC security lights are fitted of an average gate FIGURE 37 You will need to fit a deep cycle low maintenance battery minimum 35Ah in order to provide sufficient back up capacity during days of poor weather The charger supplied with the standard D5 Evo system must also be replaced with a high efficiency solar regulator These are typical values for Southern Africa Contact Centurion Systems Pty Ltd or your gate automation specialist for details on what solar panel to select in your area 6 2 2 D10 and D10 Turbo It is possible to adapt in the D10 as well as D10 Turbo for solar charging however typically 2 x 20W panels wired in series with the 24V battery supply will be required Contact Centurion Systems Pty Ltd or your gate automation specialist for details page 26 6 3 Lightning Protection The D5 Evo D10 and D10 Turbo controllers come standard with on board lightning protection but please make sure that an adequate earth is installed for this to function properly Please contact Centurion Systems Pty Ltd for more information Lightning damage is not covered under the normal warranty of the equipment page 27 Additional features i Basic maintenance 7 Basic maintenance Be CENTSYS operators are designed to be maintenance free H
32. so the Autoclose function activates gate to Ben page 11 must be enabled in FIGURE 16 order for the gate to close If the gate is already open or opening triggering the free exit input will have no effect other than to reset the Autoclose timer If the gate is closing triggering the free exit input will immediately stop and re open the gate An infrared beam can be used instead of an inductive ground loop but the beam will be activated if a person or any object moves through it so this option is typically less secure Please contact Centurion Systems Pty Ltd for more information on whether a ground loop or infrared beam is better suited to your needs page 13 Features and functions 5 1 6 PIRAC Mode Beam Autoclose Mode optional page 18 is fitted This mode can be used in conjunction with any of the operating modes Standard Condominium and Reversing With PIRAC Mode enabled your gate will close as soon as you have driven through and passed the safety beam giving intruders no time to follow behind you If Autoclose is enabled and the gate has been opened but nothing moves through the Closing Safety Beam the gate will stay fully open for the duration of the Autoclose timer before closing However if something passes through the Closing Safety Beam the gate will close immediately If something crosses the beam while the gate is opening it will continue to open until the be
33. ss Control System Proximity reader allowing for access to both pedestrians and vehicles while offering a higher level of security than a keypad Pedestrian keyswitch SOLO Lattice Proximity Access Control System Allows for pedestrians to partially open the gate using a k 4 i Pedestrian ey keyswitch POLOphone Intercom System Allow visitors to communicate with residents in order to gain access to the property POLOview Surveillance System Enhances the POLOphone to POLOphone provide CCTV at the gate fitercom Surveillance System Theft resistant Cage Retro installable steel cage that increases the resistance of the DS Evo Theft resistant operator against theft cage Optional extras D10 Theft resistant cage FIGURE 38 page 33 CENTSYS 0 07 B 0011 D5 Evo D10 D10 Turbo User guide 5J ul2012 www centsys com au
34. tesy Pillar Lights on and off Please refer to Onboard Multichannel Receiver page 22 for more information on the various functions you can operate with your remote control Low wattage 12V DC light fittings are also readily available and can be connected to the system drawing power directly from the battery However please ensure that the power drawn by the lights and motor does not exceed the recharge rate of the battery Larger charger units can be fitted to cope with the additional load contact your gate automation specialist or Centurion Systems Pty Ltd for more info e 5 1 14 2 Courtesy Pillar Lights act as Warning Light For additional safety the Courtesy Pillar light output can be configured to act as a warning light before the gate operates and while the gate Is moving Contact your gate automation specialist or Centurion Systems Pty Ltd for more details on the different warning light modes FIGURE 30 e 5 1 14 3 Pre open and pre close delays If you make use of the Warning Light feature you can set your gate to have a slight delay before it opens or closes to allow the light to warn pedestrians or vehicles that the gate is about to move The pre open and pre close delays can be independently set and also independent of enabling the warning light feature referred to above page 21 Features and functions 5 1 15 Onboard Multichannel Receiver The D5 Evo D10 and D10 Turbo controll
35. ttery supply with a switch mode charger means your batteries are always full but if you re still hungry for power the battery capacity can be increased by using an externally mounted unit Similar to the D5 Evo the D10 D10 Turbo batteries can also be charged by a solar panel instead of a 220V mains Supply at the gate As with the D5 Evo the D10 D10 Turbo controller with LCD interface is a cinch to set up and it offers an equally impressive list of useful features including CENSYS s ChronoGuard timer technology Of course accurate position control sensitive anti crushing and precision stopping power come standard D10 Turbo overview The D10 Turbo is perfectly suited for sites requiring a high number of operations per day and very fast opening and closing speeds and can reach almost double the speed of the standard D10 However it is recommended that gates weighing more than 240kg are not operated at maximum speed as the inertia generated by heavier loads might prove detrimental to the gearbox at such high speeds page 3 Identification of parts P1 D5 Evo parts identification TEUA Refer to the drawings below for how to identify your D5 Evo operator and its parts pe 10 11 12 D5 Evo controller Courtesy light fuse 3A F B Gate mounted origin Marker Origin marker bracket Origin sensor Side covers Foundation plate Motor fuse 30A ATO 1x 12V 7 2Ah battery
36. tures PIRAC Beam Autoclose page 11 can be used with and Condominium Mode functions e 5 1 2 4 PLC Mode This highly specialised mode is suited to industrial applications where a separate computer or programmable logic controller PLC is used to operate the gate Three separate inputs are used to open stop or close the gate e Free exit input a trigger from the PLC will only open the gate Holiday Lockout input a trigger from the PLC will stop the gate Trigger input a trigger will only close the gate Autoclose page 11 and PIRAC Beam Autoclose page 14 cannot be used with PLC Mode e 5 1 2 5 Deadman Control Mode A variation of PLC Mode Deadman Control Mode requires a pushbutton to be held in order for the gate to be set in motion If the button is released the gate will immediately stop Alternatively an emergency stop pushbutton can be used to permanently hold the gate in Stop Mode Releasing the pushbutton will allow your gate to open or close If the open or closed triggers are held when the gate reaches the end of its cycle either fully open or fully closed the internal end of travel limit switch system will shut off the motor and prevent further operation in the respective direction Autoclose page 11 and PIRAC Beam Autoclose page 14 cannot be used with Deadman Control Mode page 10 5 1 3 Automatic closing Autoclose Mode The D5 Evo and the D10 D10 Turbo sliding gate operators have t
37. ultiple Modes of Operation alarm functions an onboard multichannel receiver ChronoGuard full 7 day timer you name it the D5 Evo s got it The integral 12V 7 Ah battery charged by an internal 220V charger comes with full battery back up and advanced lightning protection so you can always get in even when the power is out It is important to note that the battery is the primary power source of the D5 Evo You can increase the capacity of the battery with an externally mounted battery to give longer power failure autonomy Instead of the 220V charger you can have a low voltage charger mounted inside the D5 Evo with a plug in transformer plugged into the nearest plug point inside the house building This saves having to run an electrically compliant 220 240V supply to the D5 Evo Finally you can use a solar panel to charge the battery See section 6 2 Solar power supply for more details about solar charging page 2 The D10 s 24V DC motor is coupled to the gearbox resulting in a combination of speed and power that can push up to a 1000kg sliding gate perfect for industrial sites such as business parks housing estates and factories The precision machined die cast aluminium gearbox incorporates a self locking gearset and not only makes short work of massive gates but the attempts of prospective criminals too Add the optional theft resistant cage and criminals will have to think about a change of occupation A 24V 7Ah ba
38. uthorised personnel may void the warranty page 29 9 Specifications aa Technical specifications Technical data D5 Evo D10 D10 Turbo Input voltage 220 240V AC 10 220 240V AC 10 220 240V AC 10 50Hz 50Hz 50Hz Motor voltage 12V DC 24V DC 24V DC Motor power supply Battery driven Battery Driven Battery Driven 2A charger 2 0A charger 2 0A charger Push force rated 17kgf 30kgf 15kgf Gate speed varies 18 22m min 22 26m min 40 50m min with load Duty cyle mains 50 Kr 45 Kr 25 Kr present Daily operations 150 750 750 max Gate mass max 500kg 1000kg Varies with speed amp Onboard receiver CENTSYS code hopping CENTSYS code hopping CENTSYS code hopping specification multichannel 433MHz multichannel 433MHz multichannel 433MHz capacity 500 capacity 500 capacity 500 transmitter buttons transmitter buttons transmitter buttons D10 Turbo maximum operating speed for corresponding gate mass Gate mass kg Operator max running speed m min 240 50 300 40 400 36 500 32 600 29 700 27 Specifications 800 25 900 24 1000 23 Can operate off a solar supply consult Centurion Systems Pty Ltd for assistance 7Ah battery can be upgraded for longer power failure autonomy Based on a push force of less than 50 of rated Based on 25 C ambient temperature and unit not in direct sunlight X With brush replacement interval of two years 4 See D1
39. valid trigger is received Please refer to Gate Status Indication page 20 for more information on this diagnostic device page 17 Features and functions 5 1 11 Infrared Safety Beam optional but recommended e 5 1 11 1 Closing Safety Beams Closing Safety Beams provide additional protection against your gate closing on Features people pets or vehicles and functions If the closing beam is broken while the gate is opening it will continue to open If the gate is open the gate cannot be closed and if the gate is closing it will stop and reopen If you select the Autoclose page 11 feature the gate Gate open gate cannot close will remain open if the beam Gate closing gate stops and reopens is broken and only close Gate opening gate continues opening after the set Autoclose time FIGURE 24 has expired when the beam has cleared You can use other protection devices like an inductive ground loop instead of an infrared beam but loops are only sensitive to the presence of a vehicle large metal objects and provide no protection to people or other objects in the path of the gate Please contact Centurion Systems Pty Ltd for more information on suitable protection devices e 5 1 11 2 Opening Safety Beams These beams prevent your gate from opening if an object or person is in the way If the beams are broker aul while the gate is closed the gate will not open If the gat
40. wer failure energy is drawn from the battery but not replaced Battery Low Protection will shut off the gate system to prevent running the battery flat when the battery voltage drops below e D5 Evo 10 5 volts e D10 D10 Turbo 21 volts The Gate Status Indication LED will flash three times every 2 seconds and the controller LCD will state Battery Low The gate will complete its current cycle close and then shut down until the battery voltage has recovered If you see the Battery Low signal check that the power circuit feeding the gate motor is switched on otherwise contact your local gate automation specialist or Centurion Systems Pty Ltd for assistance page 25 Features and functions Additional features 6 Additional features SS 6 1 Battery saver In the event of a Battery Low shutdown only the motor will stop drawing current the controller infrared beams and any other peripheral device will continue to draw power and flatten the battery however at a much slower rate An optional low cut out switch product code CP107 totally disconnects the battery and protects it from being fully discharged and potentially damaged Contact your gate automation specialist or Centurion Systems Pty Ltd for further details FIGURE 36 x Currently only available for the D5 Evo not the D10 D10 Turbo 6 2 Solar power supply 6 2 1 D5 Evo A solar panel can be used to E 7 a
41. your property while you are away One of the buttons on your remote control can be used to switch the Holiday Lockout Mode as well as a latching keyswitch or keypad mounted adjacent the gate entrance accessible from the outside of the property When Holiday Lockout Mode is enabled any of the access control devices that are connected to the D5 Evo D10 and the D10 Turbo will be inactive and not even tampering with the keyswitch keypad or access tag readers on the outside of the property will open the gate particularly useful if you intend leaving your property unattended for extended periods of time elec tronically FIGURE 20 If Holiday Lockout Mode is enabled while the gate is moving or in the open position it will only activate when the gate is back in the closed position If somebody tries to open the gate via a valid access control device such as a remote control etc with Holiday Lockout Mode enabled the onboard buzzer will beep periodically for 30 seconds to confirm that the gate operation has been disabled using this feature page 15 Features and functions e 5 1 7 1 Emergency Stop The Holiday Lockout function can also be used as an Emergency Stop function Mount an emergency stop pushbutton in a weatherproof housing near the gate and you can bring your gate to an immediate stop with just one press The emergency stop button must be reset before the gate can be operated again
Download Pdf Manuals
Related Search
Related Contents
MODE D`EMPLOI - Fédération Française du prêt à porter féminin User`s Manual 16 Cadera - MiMayorista.com American Standard Town Square Fixture-Mounted Bidet Fitting 2555.401 User's Manual Sennheiser CC 515 IP Electronic Barometer Model: BA113 User Manual Black & Decker Sander DS321 User's Manual 76_1237304479 ST331 - MANUAL DE INSTRUÇÕES Copyright © All rights reserved.
Failed to retrieve file